Home

Net Optics Link Aggregator Tap 10/100 In-Line to GigaBit with SFP Monitor Ports User's Manual

image

Contents

1. i du EEEH EHE I T Link LEDs Figure 2 Front Panel Power Connectors fe CA 3 Power LEDs Figure 3 Rear Panel Optics 10 100 In Line Link Aggregator Tap LED Indicators PWR 1 PWR 2 Main and Redundant Power If the Tap is deployed with both power supplies both LEDs illuminate when the Tap is plugged in If an LED is off this indicates that the corresponding power supply is not connected or not functioning Activity Indicator When there is activity on the link LED flashes green Link Indicator When a good link is established the LED is a solid green Connecting to the Network To connect to the network 1 Connect Network Port 1 to the appropriate switch server or router device using a CAT5e RJ45 cable 2 Connect Network Port 2 to the appropriate switch server or router device using a CAT5e RJ45 cable
2. 1 To Monitor Device Figure 5 Connecting to Monitoring Devices using SFP modular connectors 4 Insert the SFP in the Monitor 1 Port until you hear it click into place 5 Connect Monitoring Port 1 to the appropriate port on the monitoring device This will monitor all aggregated links connected to the network ports 6 If you are installing multiple SFPs repeat Steps 1 through 4 for Monitor Port 2 OSA Optics 10 100 In Line Link Aggregator Tap Note The 10 100 Link Aggregator is shipped with the following default dip switch settings It is strongly recommended that you do not make any changes to these settings except when needed and only to switches 2 4 5 and 6 If Switch 3 for example is toggled to on the Link Aggregator will not get a valid link In the event that the aforementioned occurs it will be necessary to return the dip switches to the default states and to power cycle the unit AUTO NEGOTIATION DUPLEX LINK FAULT RESERVED 10 100 RESERVED ei ON ON ON ON ON FD ON ON OFF OFF OFF OFF OFF HD OFF OFF 12345678 O Li Li Li Li Li NOTE To activate push butto
3. To A switch server or router JE i To B switch server or router 41 li li E Figure 4 Connecting to the Network 3 Repeat Steps 1 and 2 for the rest of the network ports of the Link Aggregator Tap 4 Verify that the Link Aggregator Tap Network Ports are cabled in line between two devices Note The second power supply is available to support the flow of traffic to the monitoring device should the first power supply fail If the first power supply is unavailable the second power supply supplies all power for the Tap Optics 10 100 In Line Link Aggregator Tap NOTE At 10Mbps if any of the network links are unplugged during operation it will be necessary to restart traffic from the connected network devices upon re connecting to the Link Aggregator This is to ensure that traffic is properly copied to the monitor ports and only applies to networks running at 10Mbps Connecting Monitoring Devices 1 Supply power to the Tap using the power supply adapter included with the unit Verify that the power LED illuminates 2 Remove the SFP from its protective packaging 3 Remove the temporary plug from Monitor Port 1
4. Lamm a Optics Installation Guide for Link Aggregator Tap 10 100 In Line to GigaBit with SFP Monitor Ports Doc PUBLAIF4CU4SFPU Rev 1 10 08 OSA LE NOptics 10 100 In Line Link Aggregator Tap Contents Introduction eo 1 Key Fe tures sica a eae d eps 2 Application Diagram un sed dai en Pd oa es 3 Cabling Guidelines sete umet got ee 3 Product Diagrams osos eseat s re rm a Yun 4 LED Indicators ec ein ave o rente ec oec ce dn 5 Connecting to the Network Ae mo ess de Zale a EEEE 5 Connecting to the Monitoring Device WWW KK eee KK KK KK 6 Dip Switch Settings nn sed asd alla a ane l al awel anny l dic dec Pd a y e 7 Specifications I A 8 Limitations on Warranty and Liability 2 2 KK KK KK RR KK KK 9 OSA LENOptics 10 100 In Line Link Aggregator Tap PLEASE READ THESE LEGAL NOTICES CAREFULLY By using a Net Optics Tap you agree to the terms and conditions of usage set forth by Net Optics Inc No licenses express or implied are granted with respect to any of the technology described in this manual Net Optics retains all intellectual property rights associated with the technology described in this manual This manual is intended to assist with installing Net Optics products into your network Trademarks and Copyrights 2007 by Net Optics Inc Net Optics is a registered trademark of Net Optics Inc Additional com pany and product names may be trademarks or registered
5. all layers for comprehensive troubleshooting No IP address is needed for the Tap or monitoring device enhancing monitoring security Redundant power ensures monitoring uptime Fully RoHS compliant Fully IEEE 802 3 compliant Ease of Use LED indicators show redundant power speed link and activity status Front mounted connectors support easy installation and operation Monitoring and network cables included for plug and play deployment Silk screened application diagram illustrates all connections for easy deployment Small form factor pluggable SFP monitor port connectors increase monitoring options Compatible with all major manufacturers monitoring devices including protocol analyzers probes and intrusion detection prevention systems Support Net Optics offers free technical support throughout the lifetime of your purchase Our technical support team is available from 8 am to 5 pm Pacific Time Monday through Friday at 1 408 737 7777 and via email at ts support netoptics com FAQs are also available on Net Optics website at www netoptics com Optics 10 100 In Line Link Aggregator Tap Application Diagram 10 100 In Line Link Aggregator Tap GigaBit SX GigaBit SX Monitoring Monitoring Device 2 Switch Switch Figure 1 Application Diagram Zero Delay A Net Optics Breakthrough Highly sensitive network locations can improve monitoring performance via the innovative features of Net
6. Optics Taps If power is lost to other 10 100 Taps the connected devices may introduce delays as they detect the power loss and try to re establish their link Net Optics pioneering design ensures that any loss of power to the Tap is transparent to the network and does not affect the flow of traffic through the Tap eliminating packet delay and loss as potential security issues Cabling Guidelines e f connecting to Switches or Hubs use CAT5e RJ45 cross over cabling e If connecting to routers or NICs use CAT5e RJ45 straight through cabling Optics 10 100 In Line Link Aggregator Tap Unpacking and Inspection Carefully unpack the 10 100 In Line Link Aggregator Tap and check for dam aged or missing parts The Link Aggregator Tap ships with the following 10 100 In Line Link Aggregator Tap Two power cords Installation Guide In addition to the Port Aggregator you should have ordered at least one SFP module You may have also ordered an extended warranty Carefully check the packing slip against parts received If any part is missing or damaged contact Net Optics Customer Service immediately Part Number Description LA IFACU ASFP In line 10 100 to SFP Link Aggregator LA IFACU ASFP 48V In line 10 100 to SFP Link Aggregator 48V DC Product Diagrams Power LEDs Monitor Ports Network Ports li
7. UDES BUT IS NOT LIM ITED TO LOST PROFITS LOST SAVINGS AND ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT even if Net Optics has been advised of the possibility of such damages Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages so the above limitation or exclusion may not apply to you Net Optics Inc warrants this Tap to be in good working order for a period of ONE YEAR from the date of purchase from Net Optics or an authorized Net Optics reseller Should the unit fail anytime during the said ONE YEAR period Net Optics will at its discretion repair or replace the product This warranty is limited to defects in workmanship and materials and does not cover damage from accident disaster misuse abuse or unauthorized modifications If you have a problem and require service please call the number listed at the end of this section and speak with our technical service personnel They may provide you with an RMA number which must accompany any returned product Return the product in its original shipping container or equivalent insured and with proof of purchase Additional Information Net Optics Inc reserves the right to make changes in specifications and other information contained in this document without prior notice Every effort has been made to ensure that the information in this document is accurate Net O
8. and scans incoming traffic from the network ports on a round robin basis Buffer size and scan rate is optimized to ensure that no packets are dropped and there is no bandwidth limitation on incoming data streams The buffers and the high bandwidth of GigaBit monitor ports guarantee that no data is lost during traffic surges Security and Visibility Without an IP address monitoring devices are isolated from the network dramatically reducing their exposure to attacks However the monitoring device connected to the Tap still sees all full duplex traffic as if it were in line including Layer 1 and Layer 2 errors Reliability For extra uptime protection Net Optics Taps offer redundant power connec tions Should the primary power source fail the Tap automatically switches to the backup power source Power LEDs on the front of the Tap indicate the current power source Lom Optics 10 100 In Line Link Aggregator Tap Key Features Passive Secure Technology Supports full duplex monitoring of four links with a single NIC increasing monitoring efficiency Optional Regeneration Tap technology enables up to four devices to simul taneously monitor all aggregated traffic Unique Zero Delay technology ensures no packet delay or loss if power is lost to the Tap Provides complete full duplex visibility at 10 or 100 Mbps without data stream interference or introducing a point of failure Passes all traffic including errors from
9. ns UP This diagram shows all segments in the OFF position Figure 6 Default Dip switch Settings Optics 10 100 In Line Link Aggregator Tap Specifications Environment Operating Temperature 0 C to 55 C Storage Temperature 10 C to 70 C Relative Humidity 10 min 95 max non condensing Power Power Supply Input 100 240VAC 0 5A 47 63Hz DC Power Input 48 VDC typical 36 VDC min 75 VDC max Mechanical Dimensions 1 75 high x 17 125 deep x 17 wide Certifications Fully RoHS compliant Copper Interface Cable Type 22 24 AWG unshielded twisted pair cable CATS CAT5e Link Distance Supported 100 meters Optical Interface Fiber Type Multimode Corning 62 5 125um wavelength 850nm Fiber Type Singlemode Corning 8 5 125j m wavelength 1310nm Connectors LA IF4CU 4SFP and LA IFACU ASFP 48V 8 RJA5 8 pin connectors network ports 4 SFP ports for SFP modular connectors Accessories SFP Conversion Kits SFPKT SX Multimode fiber SFP with cable SFPKT LX Singlemode fiber SFP with cable SFPKT CU GigaBit copper SFP with cable mn Optics 10 100 In Line Link Aggregator Tap Limitations on Warranty and Liability Net Optics offers a limited warranty for all its products IN NO EVENT SHALL NET OPTICS INC BE LIABLE FOR ANY DAMAGES INCURRED BY THE USE OF THE PRODUCTS INCLUD ING BOTH HARDWARE AND SOFTWARE DESCRIBED IN THIS MANUAL OR BY ANY DEFECT OR INACCURACY IN THIS MANUAL ITSELF THIS INCL
10. ptics is not responsible for typographical errors THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS EXPRESS OR IMPLIED No Net Optics reseller agent or employee is authorized to make any modification extension or addition to this warranty Net Optics is always open to any comments or suggestions you may have about its products and or this manual Send correspondence to Net Optics Inc 5303 Betsy Ross Drive Santa Clara CA 95054 USA Telephone 1 408 737 7777 Fax 1 408 745 7719 Email info Onetoptics com Internet www netoptics com All Rights Reserved Printed in the U S A No part of this publication may be reproduced transmit ted transcribed stored in a retrieval system or translated into any language or computer language in any form by any means without prior written consent of Net Optics Inc with the following exceptions Any person is authorized to store documentation on a single computer for personal use only and that the documentation contains Net Optics copyright notice mn SP Optics 10 100 In Line Link Aggregator Tap Notes www netoptics com 2008 by Net Optics Inc All Rights Reserved
11. trademarks of the individual companies and are respectfully acknowledged Additional Information Net Optics Inc reserves the right to make changes in specifications and other information contained in this document without prior notice Every effort has been made to ensure that the information in this document is accurate Lom Optics 10 100 In Line Link Aggregator Tap Introduction Thank you for choosing the most versatile monitoring Tap available today Net Optics Link Aggregator Taps are an efficiency breakthrough for passively monitoring multiple full duplex links Whether you are a novice or an expert this installation guide is designed to help answer any questions and to provide a quick set up reference Net Optics Link Aggregator Tap provides superior monitoring coverage while leveraging monitoring resources Providing traffic from multiple network links the Link Aggregator Tap combines up to four full duplex 10 100BaseT links eight half duplex data streams into one two or four GigaBit monitor ports Installing a monitoring device in each segment of the network is often time consuming and expensive Restricted by tight budgets security managers must make compromises that leave portions of the network exposed to attacks Net Optics Link Aggregator addresses this challenge by increasing the num ber of links covered by monitoring devices already installed No Packets Left Behind The Link Aggregator Tap buffers

Download Pdf Manuals