Home

NEC Express5800/R110d-1E Installation Guide

image

Contents

1. NEC ESMPRO Manager Ver 5 Installation Guide Linux 2 Change the setting of the NEC ESMPRO Manager Edit the server xml file to enable SLL The server xml is in the directory containing the NEC ESMPRO Manager Move to the conf directory that there is a server xml file cd opt nec es_manager wbserver conf Open the server xml file with an editor tool search the description of lt Connector gt which is specified port number 8443 and modify the description to a comment form with lt and gt Modify the port number if you need Add the keystore file path and the password that is specified at the time creating the keystore in the description of lt Factory gt lt Define a SSL HTTP 1 1 Connector on port 8443 gt lt NOTES Delete these lines lt Connector port 8443 NOTES Change it if you need maxHttpHeaderSize 8 192 maxThreads 150 minSpareThreads 25 maxSpareThreads 75 enableLookups false disableUploadTimeout true acceptCount 100 scheme https secure true clientAuth false ssIProtocol TLS gt keystoreFile lt the directory that contains keystore gt keystore keystorePass lt the password gt NOTES Add these lines I gt gt NOTES Delete these lines 3 Reboot the server Reboot the server installed the NEC ESMPRO Manager 4 Login Confirm to login to the NEC ESMPRO Manager with https Make access to the follow
2. Remote installation NEC ESMPRO Manager Unknown UDP 137 OS of the NEC lt gt ExpressUpdate Agent Unknown TCP 445 OS When managed component s OS is Windows type Remote installation of NEC ESMPRO Manager Unknown TCP 22 OS the NEC 1 gt ExpressUpdate Agent When managed component s OS is Linux type 2 The NEC ESMPRO Manager port number used for communication with the BMC can be changed on the Environment screen 3 Unknown means that the module uses one port that any module does not use 4 The module uses one port of the range 2 5 3 NEC ESMPRO Manager Component gt EM Card Function NEC ESMPRO Manager Protocol EM Card Component direction Module Name Port No Port No Module Name Information Collection NEC ESMPRO Manager 47117 UDP 623 EM Card 2 D NEC ESMPRO Manager 47170 TCP IP 623 EM Card 47179 gt 4 NEC ESMPRO Manager 47180 UDP 623 EM Card 47189 gt 4 Component NEC ESMPRO Manager 47117 UDP 623 EM Card Monitoring 2 s BMC configuration of NEC ESMPRO Manager 47117 UDP 623 EM Card CPU blade 2 Operation with NEC ESMPRO Manager 47117 UDP 623 EM Card Command Line I F 2 s 2 The NEC ESMPRO Manager uses a same port number for communication with BMC and EM card The port number can be changed on the Environment screen 4 The module uses one port of the range 2 5 4 NEC ES
3. gt Managed Component Function NEC ESMPRO Manager Server Protocol Managed Component Module Name Port No direction Port No Module Name Remote Console NEC ESMPRO Manager 47115 UDP 2069 System BIOS CUI non SOL lt gt Remote Console NEC ESMPRO Manager 47117 UDP 623 BMC CUI SOL 2 Power Control NEC ESMPRO Manager 47117 UDP 623 BMC 2 en Component NEC ESMPRO Manager 47117 UDP 623 BMC Monitoring 2 gt Information Collection NEC ESMPRO Manager Unknown TCP 47120 NEC ESMPRO Agent through NEC 3 s 47129 Extension ESMPRO Agent CA NEC DianaScope Extension or Agent DianaScope Agent Information Collection 47117 UDP 623 BMC through BMC 2 gt Remote Batch NEC ESMPRO Manager 47117 UDP 623 BMC 2 PEEN Scheduled Running NEC ESMPRO Manager Unknown TCP 47120 NEC ESMPRO Agent 3 D 47129 Extension NEC CA DianaScope Agent Operation with NEC ESMPRO Manager 47117 UDP 623 BMC Command Line I F 2 gt Alert from BMC NEC ESMPRO Manager 162 UDP 623 BMC Search of NEC ESMPRO Manager Unknown UDP 427 NEC ExpressUpdate NEC ExpressUpdate E Agent NEC ExpressUpdate NEC ESMPRO Manager Unknown TCP Unkown NEC ExpressUpdate Agent ee Agent Event Monitoring NEC ESMPRO Manager 8080 TCP Unknow NEC ExpressUpdate lt gt n Agent 20 NEC ESMPRO Manager Ver 5 Installation Guide Linux
4. 1 6 Power Management so ecscecosceigessvesseessie sice Ee EENS EEN 33 4 1 7 About CPU blade auto registration ee eeceeceseceseceseceecaeecaeeeseseeeeeeeeseeeeensecnseeeensees 33 4 1 8 About the coexistence of NEC ESMPRO Manager with DianaScope Agent or NEC ESMPRO Anget Extension on the same component 0 eecseeecseesecsseeeceseceeesecaeeseenaeeeeeaecaeeaeeneeseens 33 4 2 About NEC ExpressUpdate eire r s amp s R A A E ES 34 4 2 1 About installation of NEC ExpressUpdate Agent 34 4 3 About Managed Component ss renere Eiee a ei e eNe EEE EE uge ie e Sy 36 4 3 1 About Windows Fit ewallessrnnin innean aa a e a E aaa 36 4 3 2 About Remote Consoles irisean E a RE E E E E 36 4 3 3 About shutdown OSs nessa a a eid Agia E Wein E E hae 38 4 3 4 About shutdown OS during DC OFF state by scheduled running 38 NEC ESMPRO Manager Ver 5 Installation Guide Linux 44 4 5 About BMC Configurations eiser S ier a a e a aa Rri 39 4 4 1 About BMC Configuration tool 39 4 4 2 In Case of Exchange of management DC 39 4 4 3 About the function Obtain an IP Address automatically ODHCHP 39 4 4 4 About the Port that BMC USes misanna nn a e r er 40 4 4 5 About the initialization of the BMC Configuration Information setting 1 0 0 0 eee 40 About Webeheut sire oe asa e a a a e e eae i Ea eE a RE RTE 41 4 5 1 About the operation from two or more browserg 41 4 5 2 About downloading configuration information Die 41 4 5 3 About the login to EXPRESSSCOPE Engin
5. 3 1 About Windows Firewall If Windows firewall is enabled on the managed component DianaScope Agent or NEC ESMPRO Agent Extension may not work correctly Please perform following settings 1 Open Windows firewall from control panel of Windows 2 Select Add Port on Exceptions tab page 3 Enter following setting Name arbitrary name Port number Port number that you need to add If DianaScope Manager cannot communicate with DianaScope Agent or NEC ESMPRO Agent Extension 47120 47129 TCP UDP TCP 4 3 2 About Remote Console 4 3 2 1 About SOL The SOL Serial over LAN system implements a CUI remote console via LAN by the following method the BMC gets redirection data that has been output to the serial port 2 by System BIOS or console less OS and transmits the data via the LAN If the remote console has been set in the BMC configuration information the serial port 2 COM2 cannot be used for connecting another device such as UPS because the BMC occupies the serial port 2 Please refer to Appendix C Managed Components Summary of the NEC ESMPRO Manager Ver 5 Setup Guide to confirm the managed component supports SOL The remote console of Linux or SAC Special Administration Console of Windows Server 2003 can be used when the managed component support SOL However there are the following notes Use of serial port 2 is restricted See 2 4 1 Notes on Managed Components and Network Devices
6. Tools Search Environment Setting and other commands are displayed in the bar This bar is called Header menu 3 5 Setting Environment You can change the optional setting of the NEC ESMPRO Manager Click Environment Setting on the Header menu to check the setting For details see the online help 27 NEC ESMPRO Manager Ver 5 Installation Guide Linux 3 6 Change of the http connection port number After installation of NEC ESMPRO Manager you can change a port number to use 1 Stop the NEC ESMPRO Manager etc rc d init d esmsm stop etc rc d init d esmweb stop 2 Edit the server xml file to change a port number The server xml is in the directory containing the conf directory of the installation directory of NEC ESMPSRO Manager Move to the conf directory that there is a server xml file cd opt nec es_manager wbserver conf Open the server xml file with an editor tool search the description of lt Connector gt which is specified port number 8080 and change a port number lt Defineanon TTP 1 1 Connector on port 8080 gt axHttpHeaderSize 8 192 maxThreads 150 minSpareThreads 25 maxSpareThreads 75 enableLookups false redirectPort 8443 acceptCount 100 connectionTimeout 20000 disableUploadTimeout true gt 3 Start the NEC ESMPRO Manager etc rc d init d esmsm start etc r
7. batch function While one NEC ESMPRO Manager is using the remote console function of a managed component the other NEC ESMPRO Managers cannot use the managed component s remote console function More than one NEC ESMPRO Manager cannot collect IPMI information from the same managed component concurrently Use one NEC ESMPRO Manager for managing an EM card Use one NEC ESMPRO Manager for all EM cards and CPU blades on one blade enclosure 4 1 3 About Power Control 4 1 3 1 Power OFF Power Cycle Reset and Dump Since power control is provided by hardware regardless of the state of the managed component s operating system the system may be damaged Be careful of operation under power control 4 1 3 2 Power OFF Power Cycle Reset with the BIOS Setup Utility Active Do not control the power supply while the BIOS Setup Utility is active on the managed component Otherwise the alert setting of BMC configuration will be disabled 31 NEC ESMPRO Manager Ver 5 Installation Guide Linux 4 1 4 About IPMI Information Collection While a managed component is tuned OFF some records of management controller information and FRU Field Replaceable Unit information cannot be read in Error messages about records which could not be read in are shown in the details display area The current status of some sensors cannot be read in either while the managed component is turned OFF 4 1 5 About Remote Console 4 1 5 1 Restriction on Concurr
8. document may be revised without prior notice 3 The contents of this document shall not be copied or altered without the prior written permission of NEC Corporation 4 All efforts have been made to ensure the accuracy of all information in this document If you notice any part unclear incorrect or omitted in the document contact your authorized NEC sales representative 5 NEC assumes no liability for damages arising from the use of this product nor any liability for incidental or consequential damages arising from the use of this document regardless of 4 NEC ESMPRO Manager Ver 5 Installation Guide Linux External Libraries and their Copyright activation annogen antlr Apache Axiom Apache Axis2 Apache Derby Apache commons codec Apache commons fileupload Apache commons httpclient Apache commons io Apache commons logging Apache geronimo activation Apache geronimo annotation Apache geronimo java mail Apache geronimo stax api Apache httpcore Apache httpcore nio 4 0 Apache Log4J Apache Neethi Apache Rampart Apache Struts Apache Tomcat Apache XMLBeans Apache Woden Apache WSS4J Apache Xalan Apache Xerces Apache XML Schema asm asm attrs backport util concurrent beprov jdk c3p0 cglib dom4j DWR ehcache Hibernate jalopy jaxb api jaxb impl jaxb xjc jaxen JCIFS jettison jibx bind jibx run Jline JRE Copyright Sun Microsystems Inc CopyrightOThe Codehaus Developed by
9. lt gt EM Can 21 2 5 4 NEC ESMPRO Manager Server Inside 21 Chapter3 NEC ESMPRO Manager Installation eee eeeseesecneeeececseeeecsseeecsaeceeesecneesecnaseecsaeeeesaesaeeeeens 22 3 1 NEC ESMPRO Manager Installation for Linux 2 0 0 0 ee ceeeceecseeeecseeeeceseeeeesecaeesecneesecsaseeesaeeaeeaeenees 22 3 1 1 Check before mstallation sire earn enee Hinde oat sea ee eee 22 3 1 2 Install the NEC ESMPRO Managert o 0 ee eceecceecesecesecssecaecaeecaeeeaeeeaeeeeeeeeeeseceseenseenaeenees 22 3 1 3 Update install the NEC ESMPRO Manager 23 3 2 Senge after installation deeg eege 24 3 2 1 Access setting from Web Client 24 3 3 NEC ESMPRO Manager Un installation for LinuX 0 cceeceesecseeeeceeeeeceseceeeeceaeceeesecneesesneeeeeeaees 25 3 3 1 Uninstall the NEC ESMPRO Manager 25 BA E EE 26 3 5 Setin STEE 27 3 6 Change of the http connection port number 28 Bil EE 29 Chapter4 Precautions for Uee nirai i nie i E e aE iae e A e EEren aK E a a R S 31 4 1 About NEC ESMPRO Managers scisc 1c asce seyess rr e aeea reee ne aoee iee ee ESE SENEE iei Aere 31 4 1 1 About the use after NEC ESMPRO Manager is upgraded AA 31 4 1 2 About use of two or more NEC ESMPRO Manager 31 4 1 3 About Power Control st er ste ky eel E ve sbeebs tee ded RR ee aids He es 31 4 1 4 About IPMI Information Collection cc ceescsessceseeessecsseeeceseceeesecseesesneseeceaseeesaeeaeeseenees 32 4 1 5 About Remote Console oi ec0s it ee She es in ee a as 32 4
10. of NEC ESMPRO Manager is now completed 23 NEC ESMPRO Manager Ver 5 Installation Guide Linux 3 2 Settings after installation 3 2 1 Access setting from Web Client When you access the NEC ESMPRO Manager from Web Client login to the NEC ESMPRO Manager from local beforehand Please add the address with Environment Setting Access Limitation 24 NEC ESMPRO Manager Ver 5 Installation Guide Linux 3 3 NEC ESMPRO Manager Un installation for Linux 3 3 1 Uninstall the NEC ESMPRO Manager In below input examples the installer file name is shown like esmpro 5 h 1 Start the NEC ESMPRO Manager installer esmpro 5 sh 2 The terms of the end user license agreement for the product will be displayed Input yes and Enter key 3 A message to confirm whether you continue the installation is displayed Input delete and Enter key 4 A message to confirm whether you delete the directory where update packages are stored is displayed If g y y p D g play you want to delete it input yes and Enter key When the un installation is completed the following message is displayed Uninstallation of NEC ESMPRO Manager is now completed 25 NEC ESMPRO Manager Ver 5 Installation Guide Linux 3 4 Login After installation of the NEC ESMPRO Manager is completed confirm that you can log into the NEC ESMPRO Manager 1 Make access to the following address using th
11. specify the http connector port that NEC ESMPRO Manager uses is displayed If you specify them input yes and Enter key And then input the unused port number 5 A message to confirm whether you specify the directory where update packages are stored is displayed If you specify them input yes and Enter key And then input the directory path 6 A message to register an administrator of NEC ESMPRO Manager is displayed Enter the administrator name and password e Administrator name is the user name to operate NEC ESMPRO Manager with the administrator authority When the installation is completed the following message is displayed Installation of NEC ESMPRO Manager is now completed 22 NEC ESMPRO Manager Ver 5 Installation Guide Linux 3 1 3 Update install the NEC ESMPRO Manager Install the NEC ESMPRO Manager In below input examples the installer file name is shown like esmpro 5 sh 1 Copy the NEC ESMPRO Manager installer into any directory 2 Move to the directory containing the NEC ESMPRO Manager installer The following is an example of installation into usr local bin cd usr local bin 3 Start the NEC ESMPRO Manager installer esmpro 5 sh 4 A message to confirm whether you continue the installation is displayed Input add and Enter key When the update installation is completed the following message is displayed Installation
12. 03 Standard Edition operating system Windows Server 2003 Enterprise Edition operating system Windows Server 2003 Standard x64 Edition operating system and Windows Server 2003 Enterprise x64 Edition operating system Windows Server 2003 R2 stands for Windows Server 2003 R2 Standard Edition operating system Windows Server 2003 R2 Enterprise Edition operating system Windows Server 2003 R2 Standard x64 Edition operating system and Windows Server 2003 R2 Enterprise x64 Edition operating system Windows XP stands for Windows XP Professional operating system and Windows XP Professional x64 Edition operating system Windows 2000 stands for Windows 2000 Professional operating system Windows 2000 Server operating system and Windows 2000 Advanced Server operating system All names used in sample applications are fictitious They are unrelated to existing product organization or individual names E About External Libraries which this product uses This product contains libraries External Libraries provided by the third party suppliers Suppliers Please assume and agree these libraries license documents and NOTICE files before using this product License documents and NOTICE files of External Libraries are stored in the following folders opt nec es_manager wbserver opt nec es_manager wbserver webapps axis2 WEB INF lib opt nec es_manager wbserver webapps esmpro WEB INF lib If the Exte
13. C Corporation 2011 43
14. E Software Operating System Red Hat Enterprise Linux ES 2 1 Red Hat Enterprise Linux AS 2 1 Red Hat Enterprise Linux ES 3 0 x86 Intel EM64T Red Hat Enterprise Linux AS 3 0 x86 Intel EM64T Red Hat Enterprise Linux ES 4 x86 IntelEM64T Red Hat Enterprise Linux AS 4 x86 intelEM64T Red Hat Enterprise Linux 5 x86 intelEM64T Red Hat Enterprise Linux 5 AP x86 intelEM64T Miracle Linux Standard Edition 2 1 Miracle Linux 3 0 Asianux Inside Miracle Linux 4 0 Asianux Inside 32bit 64bit Asianux Server 3 MIRACLE LINUX V5 32bit 64bit E Number of managed components Addition of component licenses permits a single NEC ESMPRO Manager to manage a maximum of 1000 components NEC ESMPRO Manager Ver 5 Installation Guide Linux 2 2 Web client The NEC ESMPRO Manager is operable on Web clients connected to the NEC ESMPRO Manager server via LAN that satisfy the following conditions The NEC ESMPRO Manager server can also be used as a Web client E Web browser Internet Explorer 7 and 8 Firefox 3 5 and 3 6 e If you use NEC ESMPRO Manager from a browser install JRE 5 0 and above on the browsing PC If JRE is not installed some screen is not displayed correctly e Java Applet and Java scripts must be executable 1024 by 768 pixels or more are recommended as a screen area in display properties NEC ESMPRO Manager Ver 5 Installation Guide Linux 2 3 Managed component This section explains conditions for compon
15. MPRO Manager Server Inside Function Web Client Protocol NEC ESMPRO Manager Server Module Name Port No direction Port No Module Name NEC ESMPRO Manager NEC ESMPRO Manager 1099 UDP 1099 NEC ESMPRO Manager 1 NEC ESMPRO Manager NEC ESMPRO Manager 8105 TCP 8105 NEC ESMPRO Manager 8109 gt 8109 21 NEC ESMPRO Manager Ver 5 Installation Guide Linux Chapter3 NEC ESMPRO Manager Installation 3 1 NEC ESMPRO Manager Installation for Linux 3 1 1 Check before installation Check the followings See chapter 2 1 to check the system requirement of NEC ESMPRO Manager server Login to Linux as root user or get authority of root by su command CHECK e NEC ESMPRO Manager installer exists on the following directory in EXPRESSBUILDER EXPRESSBUILDER revision Inx pp esmpro_sm ex 001 Inx pp esmpro_sm en 3 1 2 Install the NEC ESMPRO Manager Install the NEC ESMPRO Manager In below input examples the installer file name is shown like esmpro 5 sh 1 Copy the NEC ESMPRO Manager installer into any directory 2 Move to the directory containing the NEC ESMPRO Manager installer The following is an example of installation into usr local bin cd usr local bin 3 Start the NEC ESMPRO Manager installer The NEC ESMPRO Manager will be installed under opt nec es_manager esmpro 5 sh 4 A message to confirm whether you
16. N port NEC ESMPRO Manager can manage the component itself installed It the managed component is installed BMC that uses the standard LAN port NEC ESMPRO Manager cannot manage the component itself installed It is possible only to install NEC ESMPRO Manager and DianaScope Agent or NEC ESMPRO Agent Extension on the same component But the communication with BMC on the component is prevented by local loopback function of OS and the BMC cannot receive any packets from the NEC ESMPRO Manager 33 NEC ESMPRO Manager Ver 5 Installation Guide Linux 4 2 About NEC ExpressUpdate 4 2 1 About installation of NEC ExpressUpdate Agent To use the function of Installing ExpressUpdate Agent following configurations are necessary 1 Change following configurations with the user belongs to the Administrators group 2 See Appendix for network ports which this function uses 1 Windows XP Professional 1 Windows Firewall Configuration Control Panel gt Security Center gt Windows Firewall gt Select General tab and turn off Don t allow exceptions Select Exceptions tab and turn on File and Printer Sharing 2 Sharing Wizard Configuration Control Panel gt Appearance and Themes gt Folder Options gt Select View tab and turn off Use simple file sharing 2 Windows Vista 1 Windows Firewall Configuration Control Panel gt Security gt Windows Firewall gt Allow a program through Windows Firewall gt Select Exceptions tab and
17. NEC NEC ESMPRO5 meager Ver Installation Guide Linux Document Rev 1 14 NEC ESMPRO Manager Ver 5 Installation Guide Linux Contents Front Owes ss East kien ied weal ea ead aa oe Gaim oe eo ERE 1 Contents EE 2 External Libraries and their Copwpght A 6 About T his DOCUMENE 2 zeen fs bdses tere idee ge te es Biren eek tee teases eed aged eee 8 Chapter About NEC ESMPRO Manager cece cece cee cseeceeeeeeeeeeeeeecensecesecsaecsaecsaecaecsaecsaecsaecaeeenesenees 9 1 1 EDERT dees ssueepreeey 10 1 2 Connection Types 3 2 23 8 iieg Me eases se SS NG ee SE A Es 10 1 3 DCU ODS sss s2ce soe dee Seed GE eege Arte Zoe reegt Eed Sege ege does ode 11 1 3 1 NEC ESMPRO Agent Extension Punctton ceeeceeeeecsseeecsseceeesecaeesecneeecsaeeeesaeeaeeseenees 13 Chapter2 System Requirement beides ged a agest need 14 2 1 NEC ESMPRO Manager server 14 Didi gt Web Cent EE 15 2 3 Managed component sciei leas ah en pai nae eon aaah 16 2 4 Requirements for Connection between the NEC ESMPRO Manager Server and Managed COMPOMENE tege dE sSeesteeav bees ieavhsshacuameaged sence spapscasacebashespsusesoaseesssasdevsbeseesbeshrersucotatiens 17 2 4 1 Notes on Managed Components and Network Devices eceeceeeeeeeceeeeeeeeeeseeeeeeeeensees 18 2 5 Port numbers that NEC ESMPRO Manager ugesi 20 2 5 1 Web Client lt gt NEC ESMPRO Manager Server 20 2 5 2 NEC ESMPRO Manager Server lt gt Managed Component 20 2 5 3 NEC ESMPRO Manager Component
18. OS The NEC ESMPRO Agent Extension shuts down the operating system upon request of the NEC ESMPRO Manager BR Version Information collection Information about the versions of the operating system LAN driver and BIOS in addition to the NEC ESMPRO Agent Extension can be collected upon request of the NEC ESMPRO Manager E BMC configuration information collection change The BMC configuration information set on the managed component can be collected or changed upon request of the NEC ESMPRO Manager BR Scheduled Running According to the specified schedule sent by the NEC ESMPRO Manager the NEC ESMPRO Agent Extension shuts down the operating system at the start of the down period It also makes a setting for the BMC to turn the power OFF at the end of the down period e NEC ESMPRO Agent Extension will perform the scheduled running after the NEC ESMPRO Manager set the schedule in the NEC ESMPRO Agent Extension NEC ESMPRO Manager Ver 5 Installation Guide Linux Chapter2 System Requirements 2 1 NEC ESMPRO Manager server Install NEC ESMPRO Manager in a management PC The management PC installed the NEC ESMPRO Manager is called a NEC ESMPRO Manager server E Hardware Processor Intel Celeron 566MHz or more or equivalent compatible processor Recommended Intel Pentium III 1GHz or more Memory 128MB or more Recommended 256MB or more Availability of hard disk 256MB or more Communication Medium TCP IP network
19. RO Manager and System BIOS or BMC is not compatible with a DHCP environment Be sure to use a fixed IP address with the NEC ESMPRO Manager server in which the NEC ESMPRO Manager is to be installed To use a managed component in a DHCP environment start NEC DianaScope Agent or NEC ESMPRO Agent Extension Setting of Teaming for standard LAN with the OS providing redundancy or multiplexing with multiple network adapters for the managed component installed BMC that uses a standard LAN port The managed component installed BMC that uses a standard LAN port shares the embedded standard LAN controller between BMC System BIOS and OS but the BMC and System BIOS do not support the LAN teaming modes including AFT Adapter Fault Tolerance and ALB Adaptive Load Balancing So if the AFT mode or ALB mode was made available by OS NEC ESMPRO Manager can communicate with BMC and System BIOS only under the following conditions while Failover does not occur If RLB Receive Load Balancing is set with ALB Adaptive Load Balancing disable the RLB If RLB cannot be disabled NEC ESMPRO Manager cannot communicate with BMC Make the Teaming set address preferred primary identical to the LAN1 IP address and MAC address in the BMC configuration information Even if the configuration of LAN2 for the BMC on the managed component is available do not set LAN in the BMC configuration information Even if the configuration of LAN2 for the BMC on the m
20. Red Hat Middleware LLC Copyright Marco Hunsicker Copyright Sun Microsystems Inc Copyright Sun Microsystems Inc Copyright Sun Microsystems Inc CopyrightOThe Werken Company Copyright The JCIFS Project Copyright Envoi Solutions LLC Copyright Dennis M Sosnoski Copyright Dennis M Sosnoski Copyright Marc Prud hommeaux Copyright OSun Microsystems Inc NEC ESMPRO Manager Ver 5 Installation Guide Linux JSch JSONIC jsr173 api jta libiconv libxml2 mail OpenSAML prototype js sortable WSDL4J wstx zlib Copyright JCraft Inc Copyright Hidekatsu Izuno CopyrightOThe Apache Software Foundation Copyright Sun Microsystems Inc Copyright Free Software Foundation Inc Copyright Daniel Veillard All Rights Reserved Copyright Sun Microsystems Inc Copyright Internet2 Copyright OSam Stephenson Copyright Stuart Langridge CopyrightOIBM Corp CopyrightOThe Codehaus Foundation Copyright Jean loup Gailly and Mark Adler NEC ESMPRO Manager Ver 5 Installation Guide Linux About This Document This document introduces remote management using the server management utility NEC ESMPRO Manager for Linux and explains the complete procedures from installation to managed component s setup Before attempting to operate the server management utility NEC ESMPRO Manager read this document so as to gain an adequate understanding of the contents E Notes This document is intended for persons who are fami
21. System Event Log Collect System Event Log Sensor Information Filed Replaceable Unit Information BR Scheduled running The scheduled running function enables the setting of a down period for the managed component According to the specified schedule the managed component shuts down the operating system at the start of the down period and turns the power ON at the end Update of firmware and software on the managed component NEC ExpressUpdate NEC ExpressUpdate is the function that manages versions of modules like firmware and software on the managed component and that updates the modules NEC ExpressUpdate can download the update packages automatically for the managed component and install them without stopping the system CHECK Some update packages are not provided via NEC ExpressUpdate please see NEC Global NP re Or A peale par kasr S TOT Your Te ea COMPONEN r ae daar eaa Ei E Operation through the command line In general NEC ESMPRO Manager is operated on the Web browser The command line interface also provides commands like power control or information collection TIPS e For details of the command line interface see NEC ESMPRO Manager Command Line Interface NEC ESMPRO Manager Ver 5 Installation Guide Linux 1 3 1 NEC ESMPRO Agent Extension Function Before the following of the functions introduced in 1 3 Functions can be used NEC ESMPRO Agent Extension must be installed in the managed component E Shutdown
22. There are the following notes in the managed component which does not support SOL Do not attempt to boot Windows or Linux on the managed component when you use Remote Control function with utility boot mode via LAN connection Booting of Windows or Linux may result in a failure To operate RAID EzAssist for a SOL incompatible managed component from the CUI remote console via LAN set the item Console Redirection to Disable on the BIOS Setup Utility screen reboot the system and then boot the RAID EzAssist Configuration Utility The remote console by the redirection function of Linux and the remote console of SAC Special Administration Console of Windows Server 2003 cannot be used via LAN 4 3 2 2 Power Control with the BIOS Setup Utility Active Do not control the power supply while the BIOS Setup Utility is active on the managed component Otherwise the alert setting of BMC configuration will be disabled 4 3 2 3 CUI Remote Console of DOS To execute the CUI remote console function of the DOS screen select Component gt Console Redirection and change ACPI Redirection to Disable on the BIOS Setup Utility screen of the managed 36 NEC ESMPRO Manager Ver 5 Installation Guide Linux component if ACPI Redirection exists on the Console Redirection 4 3 2 4 CUI Remote Console after Windows Boot The remote console via LAN cannot be used for SAC if the managed component does not su
23. Turn on File and Printer Sharing 2 Sharing Wizard Configuration Control Panel gt Appearance and Personalization gt Folder Options gt Select View tab and turn off Use Sharing Wizard 3 UAC Configuration Control Panel gt User Accounts gt User Accounts gt Turn User Account Control on or off gt Turn off Use User Account Control UAC to help protect your computer 3 Windows 7 1 Windows Firewall Configuration Control Panel gt System and Security gt Windows Firewall gt Advanced Settings gt Inbound Rules gt Select File and Printer Sharing and execute Enable Rule 2 UAC Configuration Control Panel gt User Account and Family Safety gt User Accounts gt Change User Account Control settings gt Select Never notify 4 Windows Server 2003 1 Windows Firewall Configuration Control Panel gt Windows Firewall gt Select General tab and turn off Don t allow exceptions Select Exceptions tab and turn on File and Printer Sharing 5 Windows Server 2008 1 Windows Firewall Configuration Control Panel gt Security gt Windows Firewall gt Allow a program through Windows Firewall gt Select Exceptions tab and Turn on File and Printer Sharing 2 UAC Configuration Control Panel gt User Accounts gt User Accounts gt Turn User Account Control on or off gt Turn off Use User 34 NEC ESMPRO Manager Ver 5 Installation Guide Linux Account Control UAC to help protect your computer 6 Windows Ser
24. ager Ver 5 Setup Guide Managed component integrates BMC Managed component integrates EXPRESSSCOPE Engine or EXPRESSSCOPE Engine 2 Remote Management Card integrates BMC Advanced Remote Management Card integrates BMC e EXPRESSSCOPE Engine and EXPRESSSCOPE Engine 2 are generically called EXPRESSSCOPE Engine series 1 2 Connection Types There are only via LAN of connections that can be made between the NEC ESMPRO Manager server and managed component NEC ESMPRO Manager Ver 5 Installation Guide Linux 1 3 Functions The NEC ESMPRO Manager has following functions E Remote console The remote console function allows the operator to view the managed component s display screen from the remote console During POST Power On Self Test just after the power is turned ON or while DOS is active data can be input into the managed component from the keyboard The managed component s BIOS setup and POST monitoring can be enabled remotely by this function Even after Linux has been booted the operator can perform various operations such as OS setting change or application execution while viewing the managed component s screen on the remote browser e After Windows or Linux starts up login to the EXPRESSSCOPE Engine series key input and mouse operation are possible from remote KVM Information collection The information collection function allows the operator to collect information from the managed component Component Stat
25. anaged component is available do not set LAN in the BMC configuration information If the teaming is set with channel bonding on Linux please add mode and primary definition to the line of etc modprobe conf or etc modules conf as following options bondname mode 1 primary eth0 miimon 100 Setting of Teaming for LAN with the OS providing redundancy or multiplexing with multiple network adapters for the managed component installed BMC that uses a Management LAN port If the teaming setting was made available for the LAN port that NEC DianaScope Agent or NEC ESMPRO Agent Extension uses see Appendix C Managed Components Summary of the NEC ESMPRO Manager Ver 5 Setup Guide NEC ESMPRO Manager Ver 5 Installation Guide Linux Change of the hardware of a default gateway or an alert receiver In case that there is a gateway between NEC ESMPRO Manager server and a managed component re configure BMC on the managed component after the change the hardware of the gateway In case that there is not gateway between an alert receiver and a managed component re configure BMC on the managed component after the change the hardware of the alert receiver The BMC on the managed component can know MAC address of the new hardware by setting the BMC configuration Use of a dialup router or a PPP server If an alert receiver via modem uses Windows Remote Access Service please select Allow any authentication includ
26. ble for the function when it writes the BMC configuration information file If System Management tool on NEC EXPRESSBUILDER does not support the setting of the function the tool always set disable for the function when it registers the BMC configuration The tool also set disable when it writes the BMC configuration information file If remote console feature of NEC EXPRESSBUILDER does not support the setting of the function the tool always set disable for the function when it registers the BMC configuration 2 If the managed component has been installed Advanced Remote Management Card the BMC may not immediately obtain the IP address after DianaScope PXE Service configures the BMC to obtain the IP address by the DHCP Please turn the managed component AC OFF and then AC ON because the BMC try to obtain the IP address whenever the managed component is turned AC ON 39 NEC ESMPRO Manager Ver 5 Installation Guide Linux 4 4 4 About the Port that BMC uses In case that Linux on the managed component uses port 623 NEC ESMPRO Manager cannot communicate with the BMC that uses standard LAN port Please perform following settings 1 Add following entries in services files etc services to reserve port 623 asf rmcp 623 tcp ASF Remote Management and Control Protocol asf rmcp _623 udp ASF Remote Management and Control Protocol 2 Reboot the OS 4 4 5 About the initialization of the BMC C
27. c d init d esmweb start 28 NEC ESMPRO Manager Ver 5 Installation Guide Linux 3 7 SSL If you need to login to the NEC ESMPRO Manager using SSL you should change the setting of the NEC ESMPRO Manager Perform the procedure that is necessary in order to use SSL with the NEC ESMPRO Manager as follows 1 Create a key The Key tool is needed for creating the key using with SSL The Key tool is contained the NEC ESMPRO Manager Create the key as follows opt nec es_manager jre bin keytool genkey alias tomcat keyalg RSA Some messages are displayed with dialog style Input the information about the creator of the key You need to set the same password as the keystore password to the key password for lt sdo gt The following is shown an example Enter keystore password 9 What is your first and last name Unknown Scott Oaks What is the name of your organizational unit Unknown SMCC What is the name of your organization Unknown Sun Microsystems What is the name of your City or Locality Unknown New York What is the name of your State or Province Unknown NY What is the two letter country code for this unit Unknown US Is lt CN Scott Oaks OU SMCC O Sun Microsystems L _New York S NY C US gt correct no yes Enter key password for lt sdo gt RETURN if same as keystore password Confirm that the key was created keystore 29
28. e Series cccssssssesecseesecneeeecesseeeeseeeeeseenees 41 4 5 4 Mote on using Internet Explorer since version D 41 4 5 5 About Firefox ss oct Eet EES 42 4 5 6 About back button of the browser cccceccecssecessceesceceseceeseececeeeseecsseeesseeceeceesaeceeeeesaeene 42 4 5 7 About the automatic logout cece eceseseessecseesecseeseceecseesecsseeecsaecaeesecseesecnaeseceaseeeesesaeeaeenees 42 NEC ESMPRO Manager Ver 5 Installation Guide Linux E Trademarks NEC EXPRESSBUILDER and NEC ESMPRO are registered trademarks of NEC Corporation Microsoft Windows Windows Vista Windows Server are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries NetWare is a registered trademark of Novell Inc of the United States All other company or product names used in this document are registered trademarks or trademarks of their respective trademark owners Windows 7 stands for Windows 7 Professional operating system Windows 7 Ultimate operating system Windows Server 2008 stands for Windows Server 2008 Standard operating system Windows Server 2008 Enterprise operating system Windows Server 2008 Datacenter operating system and Windows Server 2008 Foundation Windows Vista stands for Windows Vista Business operating system Windows Vista Enterprise operating system and Windows Vista Ultimate operating system Windows Server 2003 stands for Windows Server 20
29. e Web browser on the Web client URL http the computer name installed the NEC ESMPRO Manager port number that the Tomcat uses esmpro An Example of address to access from the web browser on the NEC ESMPRO Manager component is shown http localhost 8080 esmpro 2 The login screen of the NEC ESMPRO Manager will be open Input the administrator name and the password that has registered at the installation and then click login NEC ESMPRO Manager Version5 Mozilla Firefox SACH s file Edit View History Bookmarks Tools Help e E B rus nocainost 8080 esmprofoginPage do jsessionid 4E4F34857B4E3583A622E is CH N EC Empowered by Innovation ESMPROS Manager Ver Ven Login Copyright C 2004 2010 NEC Corporation All Rights Reserved Done 26 NEC ESMPRO Manager Ver 5 Installation Guide Linux When the login is successful the following screen will appear NEC ESMPRO Manager Version5 Mozilla Firefox File Edit View History Bookmarks Tools Help i LC e Ki x a EI http nocatnost 8080 esmpro pages commonsitop jsp Ly Gl coogie EN Information 4Group Information Page 1 7 n KI Registration count Ocount oi EE Management Management LAN Management Management LAN D o Group information information name _ Cgnteslor e address Se 3 Add Group H Add Component Done CHECK e
30. ellation dialog may not be displayed When OS shutdown is executed at the request of NEC ESMPRO Manager When OS shutdown is executed by scheduled running function 4 3 4 About shutdown OS during DC OFF state by scheduled running When Agent Setting Shut down OS after DC ON during Scheduled Running Halt on NEC ESMPRO Manager is enabled the DianaScope Agent or NEC ESMPRO Agent Extension shutdowns OS if the managed component is powered up during the down period DC OFF state time by scheduled running Only if the managed component is powered up from NEC ESMPRO Manager DianaScope Agent or NEC ESMPRO Agent Extension does not shutdown OS However in case that any error is occurred during booting DianaScope Agent or NEC ESMPRO Agent Extension may shutdown OS even though power up by NEC ESMPRO Manager 38 NEC ESMPRO Manager Ver 5 Installation Guide Linux 4 4 About BMC Configuration 4 4 1 About BMC Configuration tool Among the BMC configuration information tools there are some tools which cannot be used to setup ESMPRO NEC MWA Agent cannot be used If the DianaScope is not stored in the NEC EXPRESSBUILDER CD ROM A setup of a system management stored in the CD ROM cannot be used The Console less function of the NEC EXPRESSBUILDER can be used only when ESMPRO is stored in the same NEC EXPRESSBUILDER CD ROM 4 4 2 In Case of Exchange of management PC If a management PC as an alert receiver has bee
31. ent Connection to the Remote Console When a single NEC ESMPRO Manager is operating the remote console of a managed component another Manager cannot execute the remote console function for the managed component A managed component can transmit redirection data to only a single NEC ESMPRO Manager 4 1 5 2 About Remote Console before OS boot or during DOS program running If a graphic screen is displayed on a managed component data cannot be displayed correctly on the CUI remote console The CUI remote console screen is displayed only when the managed component displays a text screen If the DOS program running on a managed component displays Japanese words follow these notes On the BIOS Setup Utility screen of the managed component select Server Console Redirection and change Terminal Type to PC ANSI in advance If a managed component of which BIOS Setup does not include the item Terminal Type Terminal Type is already set to PC ANSI so the managed component can be used as it is Boot the DOS in English mode with no Japanese language driver At this time the screen contents cannot be displayed correctly on the managed component but Japanese words are displayed correctly on the CUI remote console of the NEC ESMPRO Manager 4 1 5 3 About Remote Console after starting Linux Notes in the case of using the remote console after starting Linux on the managed component by the redirection function of Linux are sho
32. ents to be managed by the NEC ESMPRO Manager E Hardware The component that integrates a standard BMC conforming to IPMI Ver 1 5 or Ver 2 0 The component that integrates EXPRESSSCOPE Engine or EXPRESSSCOPE Engine 2 conforming to IPMI Ver 2 0 The component that is installed a Remote Management Card N8115 01CP01 conforming to IPMI Ver 1 5 or Ver 2 0 The component that is installed an Advanced Remote Management Card N8115 02CP01 conforming to IPMI Ver 2 0 e The monitor function by the SNMP does not support it NEC ESMPRO Manager will not be managed as the result of the install See the Appendix C Managed Components Summary of the NEC ESMPRO Manager Ver 5 Setup Guide e The required environment varies depending on the connection type with the managed component See 2 4 Requirements for Connection between the NEC ESMPRO Manager Server and Managed e EXPRESSSCOPE Engine and EXPRESSSCOPE Engine 2 are generically called EXPRESSSCOPE Engine series E Software You cannot use the monitoring function by the SNMP even if you install NEC ESMPRO Agent If you use NEC ExpressUpdate function that manages versions of modules like firmware and software NEC ExpressUpdate Agent is required NEC ESMPRO Manager Ver 5 Installation Guide Linux 2 4 Requirements for Connection between the NEC ESMPRO Manager Server and Managed Component H LAN connection TCP IP network LAN port LAN port that BMC uses de
33. hich components can NEC ESMPRO Manager control See the Appendix C Managed Components Summary of the NEC ESMPRO Manager Ver 5 Setup Guide How to operate after setup See the NEC ESMPRO Manager s online help information How to operate the command line Interface See the NEC ESMPRO Manager Command Line Interface NEC ESMPRO Manager Ver 5 Installation Guide Linux Chapter About NEC ESMPRO Manager NEC ESMPRO Manager is software designed for reducing operational management costs by remotely managing components The ESMPRO Manager is primarily made up of NEC ESMPRO Manager running on a management PC called a ESMPRO Manager server and NEC ESMPRO Agent Extension running on a managed component Remotely manageable components with ESMPRO Manager are the components that conform to IPMI Intelligent Platform Management Interface Ver 1 5 or Ver 2 0 as the industry standard for server management The ESMPRO Manager provides the following capabilities Rebuilding even if the operating system on the managed component has failed Even if the operating system on the managed component is inoperable in the state of operating system s stall BIOS POST Power On Self Test or DC OFF ESMPRO Manager allows you to collect the managed component s hardware information and control the power supply Operation while viewing the managed component s screen While key in and mouse operations are enabled the
34. ince version 6 If you login to NEC ESMPRO Manager Ver 5 from Web client using Internet Explorer since version 6 for a long time according to Internet Explorer restriction for detail see Microsoft Knowledge Base 830555 memory usage of Internet Explorer on Web client will increase About 10MB a day at maximum So please do following processes if you use it for a long time after login from Web client 1 Please logout Web client regularly The increased memory by Internet Explorer restriction will be released by logout 41 NEC ESMPRO Manager Ver 5 Installation Guide Linux 2 Please change the Update Interval value of Automatically update display setting from 5 seconds default value to 60 seconds The changing of the automatic update interval by JavaScript will decrease the unnecessary memory usage caused by Internet Explorer restriction lt procedure to change setting gt Environment setting Option Setting Automatically update display Update Interval 4 5 5 About Firefox The screen including Java Applet might not be displayed on Firefox Through the following procedure the situation can be avoided Modify the version of Java Plug in of Web browser Use Internet Explorer Disable the check box Java control panel Advanced tab Enable the next generation Java Plug in 4 5 6 About back button of the browser NEC ESMPRO Manager cannot be operated using back button The screen conte
35. ing address using the Web browser on the Web client URL https the computer name installed the NEC ESMPRO Manager port number that is specified in server xml esmpro An Example of address to access from the web browser on the NEC ESMPRO Manager server is shown https localhost 8443 esmpro 30 NEC ESMPRO Manager Ver 5 Installation Guide Linux Chapter4 Precautions for Use 4 1 About NEC ESMPRO Manager 4 1 1 About the use after NEC ESMPRO Manager is upgraded After NEC ESMPRO Manager is upgraded NEC ESMPRO Manager on the web browser may display incorrectly Take the following steps to avoid it Internet Explorer 8 1 Click the Safety menu 2 Select Delete Browsing History 3 Select the checkbox for Temporary Internet Files 4 Click the Delete button Internet Explorer 7 1 Click the Tools menu 2 Select Delete Browsing History 3 Click the Delete files button 4 Click the Yes button in the confirmation window 5 Click the Close button Firefox 3 5 3 6 1 Click the Tools menu 2 Select Clear Recent History 3 Select the Details button 4 Select the Cache checkbox 5 Click the Clear Now button 4 1 2 About use of two or more NEC ESMPRO Manager A single managed component can be controlled remotely by up to three NEC ESMPRO Manager servers Follow these notes on the remote control Use only one NEC ESMPRO Manager to set execute the scheduled running function and remote
36. ing clear text about the encryption on the Windows Remote Access Service properties Restrictions on use of the standard serial port 2 COM2 The standard serial port 2 COM2 on a managed component cannot be used for connecting another device in the following cases because the BMC occupies the serial port 2 The managed component compatible with SOL and set enable on following BMC Configuration items Remote control WAN Direct Redirection LAN Redirection WAN Direct Connection via modem or Direct connection has been made Direct connection has been set in the BMC configuration information Even if the NEC ESMPRO Manager and managed component are not connected the BMC occupies the serial port 2 COM2 CHECK See Appendix C Managed Components Summary of the NEC ESMPRO Manager Ver 5 Setup Guide to confirm whether that your component supports SOL NEC ESMPRO Manager Ver 5 Installation Guide Linux 2 5 Port numbers that NEC ESMPRO Manager uses NEC ESMPRO Manager uses the following port numbers 2 5 1 Web Client lt gt NEC ESMPRO Manager Server Function Web Client Protocol NEC ESMPRO Manager Server Module Name Port No direction Port No Module Name Management Web Browser Unknown TCP 8080 NEC ESMPRO Manager monitoring s 1 The port number used by Tomcat can be changed on setting of NEC ESMPRO Manager 2 5 2 NEC ESMPRO Manager Server
37. jGuru com http www ANTLR org and http www jGuru com Copyright Terence Parr CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOThe Apache Software Foundation CopyrightOINRIA France Telecom CopyrightOINRIA France Telecom Copyright Distributed Computing Laboratory Emory University CopyrightOThe Legion Of The Bouncy Castle http www bouncycastle org Copyright Machinery For Change Inc Copyright Ocglib Copyright MetaStuff Ltd Copyright Joe Walker Copyright Luck Consulting Pty Ltd CopyrightO
38. l emulator the hyper terminal and so on can t control Refer to the manual of each firmware or software for the details 4 1 6 Power Management The power value which NEC ESMPRO Manager reads from the managed component has about 10 margin of error The electric power value might not necessarily reach even the value of Power Cap value The electric power control lowers the power consumption of the system by lowering the frequency of CPU Memory When CPU Memory Throttling value reaches 100 the electric power value doesn t fall any more 4 1 7 About CPU blade auto registration When Check Connection of CPU blade auto registration was failed Retry of CPU Blade auto registration is not necessary You can execute Check Connection on Server Setting Connection Setting If a specified IP address is set from a CPU blade to another CPU blade during CPU blade auto registration process ex when you replace CPU blade and execute CPU blade auto registration NEC ESMPRO Manager may not be able to connect the CPU blade because old information remains in the ARP table on the management PC Wait for a few minutes and try the Check Connection 4 1 8 About the coexistence of NEC ESMPRO Manager with DianaScope Agent or NEC ESMPRO Anget Extension on the same component If the managed component is installed Advanced Remote Management Card or EXPRESSSCOPE Engine series the BMC uses Management LA
39. liar with the operating system s functions and operations and the network s functions and setup For operations and inquiries about the operating system see its online help information This document covers universal information about generally managed components The notes and restrictions on use of each product as a managed component are explained in the user s guide provided with the managed component and Appendix C Managed Components Summary on the NEC ESMPRO Manager Ver 5 If the NEC EXPRESSBUILDER SE CD ROM or Maintenance Management Tool CD ROM is attached to the managed component read the word in place of NEC EXPRESSBUILDER in this document Names used with screen images in this document are fictitious They are unrelated to existing product names names of organizations or individual names The setting values on the screen images are shown as examples so setting values such as IP addresses on screen images are not guaranteed for operation In this document expresses back slash About Symbols in This Document The following explains three symbols that are used in this document IMPORTANT Points or particular notes you must follow when handling software of components CHECK Points or notes you need to check when handling software or components TIPS Useful information E Other Documents for NEC ESMPRO Manager For other information about the NEC ESMPRO Manager see the documents below SG W
40. managed component s screen can be viewed on the remote browser at any time during POST just after the managed component is turned ON Operation of more than one managed component at a time By specifying a component group you can provide power control or change a setting for managed components through a single operation Specification of remote operation time The managed component can be turned OFF or information can be collected at pre specified time so ESMPRO Manager is available for nighttime batch processing Easy operation through the Internet The managed component can be operated with a Web browser If you use Internet s standard SSL Secure Socket Layer for the ESMPRO Manager you enable secure remote operation from an external network NEC ESMPRO Manager Ver 5 Installation Guide Linux 1 1 Components The NEC ESMPRO Manager consists of the following software group E Software running on the NEC ESMPRO Manager component NEC ESMPRO Manager Manages a remote component by communicating with the BMC Baseboard Management Controller System BIOS and DianaScope Agent or NEC ESMPRO Agent Extension which are on the managed component E Software running on the managed component NEC ESMPRO Agent Extension Configures the BMC on the managed component and executes commands specified by the NEC ESMPRO Manager e BMC is provided with form below For details see Appendix C Managed Components Summary of the NEC ESMPRO Man
41. message on the information bar In this case you can download the file with following settings 1 Click information bar on Internet Explorer 2 Click Download File 3 Please read the information carefully and select save 4 5 3 About the login to EXPRESSSCOPE Engine series 4 5 3 1 About Java Plug in To login to EXPRESSSCOPE Engine series through ESMPRO Java plug in of the web browser should be version 1 4 2_12 and above If JAVA plug in version is 1 4 2_11 and below the web browser may stall 4 5 3 2 About Microsoft Internet Explorer The login to EXPRESSSCOPE Engine series screen might not be displayed In this case add URL of the EXPRESSSCOPE Engine series to Add this Web site to the zone 1 Select Internet Options on Tools menu of Internet Explorer 2 Click the Security tab 3 Click Local Internet zone and then click Sites 4 Enter the URL of the EXPRESSSCOPE Engine series on add this Web site to the zone For example If the EXPRESSSCOPE Engine series has IP address 192 168 0 100 the URL is http 192 168 0 100 5 Click add zone and then click OK The screen including Java Applet might not be displayed on Internet Explorer Through the following procedure the situation can be avoided Disable the check box Java control panel Advanced tab Enable the next generation Java Plug in 4 5 4 Mote on using Internet Explorer s
42. n exchanged register the managed component s BMC configuration information again even when the IP address of the management PC remains unchanged Otherwise the BMC may fail to recognize the alert receiver 4 4 3 About the function Obtain an IP Address automatically DHCP The managed component included the BMC that uses a Management LAN port supports the function Obtain an IP Address automatically DHCP 1 Following version of NEC ESMPRO Manager modules supports the setting of the function Managed component DianaScope The managed component that integrates DianaScope Agent Ver 2 03 05 and above EXPRESSSCOPE Engine series DianaScope Configuration Ver 1 02 and above The managed component installed DianaScope Agent Ver 2 06 00 and above Advanced Remote Management Card DianaScope Configuration Ver 1 02 and above When you use the module that does not support the setting of the function Obtain an IP Address automatically DHCP for the managed component that supports the function please note followings If DianaScope Agent does not support the setting of the function the DianaScope Agent always set disable for the function when it registers the BMC configuration The DianaScope Agent also set disable when it writes the BMC configuration information file If DianaScope Configuration does not support the setting of the function the DianaScope Configuration always set disa
43. nts cannot be displayed correctly on browsers Choose a necessary link or a button again in that case 4 5 7 About the automatic logout NEC ESMPRO Manager logs out automatically when you don t operate a screen for more than 30 minutes When you continue the operation log in to NEC ESMPRO Manager again 42 NEC ESMPRO Manager Ver 5 Installation Guide Linux Revision History 1 00 1 01 1 03 1 05 1 07 1 08 1 09 2008 11 11 2009 01 30 2009 09 01 2009 10 22 2009 11 24 2010 01 13 2010 02 05 2010 03 23 2010 09 03 2010 11 24 2011 05 11 2011 06 17 Initial edition Appends about the NEC ESMPRO Agent Extension Appends about the Web client Modifies about Trademarks Update System Requirement Appends about the installation of NEC ESMPRO Manager Appends about NEC ExpressUpdate Corrects writing errors Modifie about the installation of NEC ESMPRO Manager Modifie about the installation of NEC ESMPRO Manager Modifie about the remote console function Modifies about license Corrects writing errors Modifies maximum number of managed components Change Universal design Update System Requirement Appends about the use after NEC ESMPRO Manager is upgraded Appends about license Appends In Case of Key in Failure on the Remote Console Appends Power Management Modifies about license Appends port numbers that NEC ESMPRO Manager uses of Tomcat NEC ESMPRO Manager Installation Manual NE
44. onfiguration Information setting When you set Default value on the BMC Configuration Information with DianaScope Agent or NEC ESMPRO Agent Extension or create New Configuration with System Management Tool started from NEC EXPRESSBUILDER CD ROM each items of the BMC Configuration Information are initialized If the managed component integrates EXPRESSSCOPE Engine series or Advanced Remote Management Card following items for BMC Web server are also initialized because they are shared with BMC Configuration Information DHCP Configuration IP Address Subnet Mask Default Gateway How to set the Web server is following Select System Management Tool on Tool started from NEC EXPRESSBUILDER CD ROM and then select Web server of BMC Login to Web server of the BMC and then select Configuration Network 40 NEC ESMPRO Manager Ver 5 Installation Guide Linux 4 5 About Web client 4 5 1 About the operation from two or more browsers NEC ESMPRO Manager cannot be operated using two or more browser windows by one Web client When you use the browser which has tabbed browsing the NEC ESMPRO Manager cannot be operated using two or more tab 4 5 2 About downloading configuration information file When you try to download the file from Configuration Information File of Linkage Service on NEC ESMPRO Manager Internet Explorer may block the download Internet Explorer will also display the
45. pends on the type of BMC Some BMC uses standard LAN port Other BMC uses a Management LAN port See the Appendix C Managed Components Summary of the NEC ESMPRO Manager Ver 5 Setup Guide There are 2 types of managed components that BMC uses standard LAN port one type is permitted to use only LANI port and the other type is permitted to use both LAN1 and LAN2 ports See the Appendix C Managed Components Summary of the NEC ESMPRO Manager Ver 5 Setup Guide NEC ESMPRO Manager Ver 5 Installation Guide Linux 2 4 1 Notes on Managed Components and Network Devices This section explains particular notes on managed components and network devices Use of network switch router If the managed component installed BMC that uses a standard LAN port or loaded Advanced Remote Management Card and there is network switch router between manager server and the managed components please set the network switch router to receive Gratuitous ARP See each instruction manual of the switch router about how to set it Use of a layer 2 layer 3 switching hub Set Disable for the STP Spanning Tree Protocol function of the switching hub or the STP of the port to which a managed component is connected Set Enable for the auto negotiation function of the port to which a managed component is connected Use of DHCP In case that BMC on the managed component uses a standard LAN port communication between the NEC ESMP
46. pport SOL To execute the CUI remote console function of the SAC screen after Windows boot select Server gt Console Redirection and change ACPI Redirection to Enable on the BIOS Setup Utility screen of the managed component When ACPI Redirection is set to Enable on the BIOS Setup Utility screen the CUI remote console function cannot be executed after POST If ACPI Redirection does not exist on the Console Redirection menu please confirm that Console Redirection after POST is enabled 4 3 2 5 CUI Remote Console under Linux The remote console by the redirection function of Linux cannot be used via LAN if the managed component does not support SOL To execute the CUI remote console function of the Linux redirection select Server gt Console Redirection and change ACPI Redirection to Disable on the BIOS Setup Utility screen of the managed component if ACPI Redirection exists on the Console Redirection When you execute a remote console by the redirection function of Linux following settings are necessary 1 Set as following example at the line that begins with kernel vmlinuz in the setting file boot grub grub conf on Linux console tty0 console ttyS 1 19200n8r 2 Make a setting like the following example in the setting file etc inittab on Linux S0 2345 respawn sbin agetty h L 19200 ttyS1 vt100 Explanation of the e
47. rnal Libraries require to include their Source Code with this product see the folder below lt The directory that extracts installer gt esm_x srce External Libraries are listed in External Libraries and their Copyright Notwithstanding any of the terms in the Agreement or any other agreement You may have with NEC a Suppliers provide the libraries WITHOUT WARRANTIES OF ANY KIND and such Suppliers DISCLAIM ANY AND ALL EXPRESS AND IMPLIED WARRANTIES AND CONDITIONS INCLUDING BUT NOT LIMITED TO THE WARRANTY OF TITLE NON INFRINGEMENT OR INTERFERENCE AND THE IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE EXTERNAL LIBRARIES NEC ESMPRO Manager Ver 5 Installation Guide Linux b In no event are the Suppliers liable for any direct indirect incidental special exemplary punitive or consequential damages including but not limited to lost data lost savings and lost profits with respect to the External Libraries and c NEC and the Suppliers are not liable to You and will not defend indemnify or hold You harmless for any claims arising from or related to the External Libraries About this product uses External Libraries and their Copyright see External Libraries and their Copyright E Notes 1 No part of this document may be reproduced in any form without the prior written permission of NEC Corporation 2 The contents of this
48. us Managed component s STATUS lamp state and power state Version Information Information about the versions of NEC DianaScope Agent or NEC ESMPRO Agent Extension operating system LAN driver and System BIOS BMC Configuration BMC configuration information You can also change the information Power Restore Delay Interval from AC ON to DC ON that is also set using BIOS Setup utility on the managed component IPMI Information Hardware information log information and the current status of each sensor Power Management Managed component s power value You can read it for specified period Power control The following power control is provided for the managed component Power ON Power OFF Power Cycle turns power on after turning it off Reset DUMP Switch The managed component performs the same operation as when the dump switch is pressed Sutdown OS Component Monitoring The component monitoring function always monitors the managed component s STATUS lamp state and power state When a failure occurs the function notifies the operator of the failure If the managed component is a CPU blade this function also monitors and notifies the operator of the slot change The component monitoring function is supported only via LAN 11 NEC ESMPRO Manager Ver 5 Installation Guide Linux E Remote batch The remote batch function enables the following control automatically at specified time Power ON Power OFF Shutdown OS Clear
49. ver 2008 R2 1 Windows Firewall Configuration Control Panel gt System and Security gt Windows Firewall gt Advanced Settings gt Inbound Rules gt Select File and Printer Sharing and execute Enable Rule 2 UAC Configuration Control Panel gt User Accounts gt User Accounts gt Change User Account Control settings gt Select Never notify 7 Windows Server 2008 R2 Core 1 Windows Firewall Configuration 1 1 Make up the remote PC to change Windows Server 2008 R2 s Windows Firewall settings remotely 1 2 Input below command on the managed component to enable remote configuration of the Windows Firewall netsh advfirewall set currentprofile settings remotemanagement enable 1 3 Input mmc at Run window on remote PC 1 4 File Add Remove Snap in gt Add Windows Firewall with Advanced Security In the Select Computer Window input the host name of the managed component You can get host name of the managed component with hostname command 1 5 Inbound Rules gt Select File and Printer Sharing and execute Enable Rule 8 Linux OS See manual of the distribution for configuration 1 Firewall Configuration Enable remote ssh login 2 SSH Configuration Enable root login with SSH Typically open the sshd configuration file etc sshd sshd_config and set the PermitRootLogin option to ves 35 NEC ESMPRO Manager Ver 5 Installation Guide Linux 4 3 About managed component 4
50. wn below The Home key and End key are not enabled when you operate Linux with the CUI remote console function If the managed component is rebooted after NEC ESMPRO Manager displays CUI remote console for the managed component that runs Linux you may not input following keys on remote console F5 F12 Arrows Insert Delete Home End Page Up and Page Down Close the remote console window and re open it 4 1 5 4 About the display of a special character The CUI remote console screen is not displayed correctly in the following cases Terminal Type If Terminal Type is not set to PC ANSI on the BIOS Setup Utility screen of a managed component Japanese words on the POST or DOS screen cannot be displayed correctly on the CUI remote console Special character Ruled lines arrows correctly and en size left arrows cannot be displayed 32 NEC ESMPRO Manager Ver 5 Installation Guide Linux 4 1 5 5 In Case of Key in Failure on the Remote Console During DOS boot or access to the FD or CD ROM drive immediately after the managed component s power switch is turned ON data cannot be keyed in from the remote console or the keyed data display may be delayed Remote Console is realized by using the Serial Over LAN SOL function of the IPMI conformity and the Serial Redirection function of BIOS Data cannot be keyed in from the Remote Console when the firmware BIOS and so on or the software requires the key code that VT100 termina
51. xample setting agetty is to be used in the following conditions Hardware control RTS CTS is enabled This setting is an example Determine whether to enable disable it conforming to the configuration information setting on the managed component A directly connected local line not requiring carrier detection is assumed Baud rate 19200 bps This setting is an example Set the baud rate conforming to the BMC configuration information setting on the managed component Seriall port 2 of the managed component is used The terminal type is vt100 Even if connection with a managed component is of any type LAN WAN or Direct Linux on the managed component recognizes that operation through the remote console of the DianaScope Manager is connection via the serial port The initial setting on Linux does not permit any super user root to log in via the serial port To log in as a super user disable the security function for the serial port 2 Be very careful of operation in this case To disable the security function for the serial port 2 add ttyS1 to the etc security file To display the editor or menu screen on the CUI remote console set the OS terminal screen to the 80 column 24 line size 37 NEC ESMPRO Manager Ver 5 Installation Guide Linux 4 3 3 About shutdown OS If the operating system of managed component is Windows since Windows Server 2008 and the following OS shutdown operates the canc