1. If fan wobbles 4 If light does not work to the service panel 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point
2. outlet box and ungrounded conductor on the other side of the outlet box Remove keeper from pin Remove pin replace keeper and save Insert downrod into motor yoke Next insert clevis pin through yoke and downrod a Carefully lift fan assembly onto mounting bracket Rotate fan so that the notch on the ball engages the ridge in the mounting bracket This will allow hands free wiring Fan M Black 77 Blue Black kz White j White G c VVVYVI Een XXXXF Green downrod E c XXXXXI Green Bracket For pullchain controls follow diagram above Make sure that all exposed wiring is secured inside wire nuts Note Wires from house may vary in color and may not include ground wire After wiring is conplete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips ri Light Switch mm mr Fan Switch Wall Control For control of fan and optional light from wall location follow diagram above NOTE A profes sional electrician is recommended for this type of installation Install 3 screws and washers per blade and tighten securely Repeat Loosen 3 screws with key slots and remove 1 screw without slot from motor plate and save screw Remove the double sided tape from capacitor and stick capacitor to switch housing Re install safety bar removed in step 3 by placing safety bar on screws sliding into place and tight ening the 2 screw
3. Owner s Manual Ceiling Fan Installation Instructions Total fan weight Ea For 5MQ60XX Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO Quality Ceiling fans no Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacurer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the eguipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows th
4. e fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING Risk of fire electric shock or personal injury The fan in this box may be either directly supported from a structural framing mem ber of a building and or may be mounted to an outlet box marked acceptable for fan support of 31 8 kg 70 Ibs or less Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced Consult a gualified electrician if in doubt Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the
5. local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Phillips Screwdriver Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Remove the 4 screws attaching the Mounting neck the mounting plate Retain the 4 screws for re assembly Wire Cutters TOOLS REQUI RED Pliers OUTLET BOX METHOD Warning Risk of fire electric shock or person al injury The fan in this box may be either directly supported from a structural framing member of a building and or may be mounted to an outlet box marked acceptable for fan sup port of of 31 8 kg 70 Ibs or less Most outlet boxes commonly used for the support of lummi naires may not be acceptable for fan support and may need to be replaced Consult a quali fied electrician if in doubt BUILDING STRUCTURE METHOD Mounting Wood Screws Secure mounting plate directly to a joist from the buliding structure via the two knock out holes on the outlet box Use only the appropri a
6. on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not sup plied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws far thest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redis tribute the weight and possibly result in smoother operation 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
7. s Remove the steel motor stabilizing plate and discard _ Install switch housing plate by twist ing plate with key hole slots into place Replace screw removed and tighten the 4 screws securely Remove 4 screws and save to install switch housing Raise the canopy up and align the two holes in the canopy with the two holes in the hanger bracket Secure with two screws provided The screws washers and motor pads are pre installed to the blade holders Attach blade assembly to motor and tighten screws securely Connect plug from fan to switch house plug s Install the switch housing using the 4 screws previously removed Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag 1 If fan does not start 2 If fan sounds noisy 3
8. te wood screws and washers included with your fan Caution Wood screws must go through into the building joist Step Ladder Remove Safety bar from mounting bracket by loosing screws sliding bar to side and lifting it off the 2 screws Install the mounting Plate to approved fan brace and box combination use only the hard ware provided with the fan brace and box Lift mounting neck to mounting Plate and align screws Loosen the 2 set screws in yoke for downrod to slip into yoke Secure with cotter pin Safety cable installation safety cable ela lock screw Washer Fan and light kit combinations over 70 Ibs in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Secure mounting neck to the mount ing plate with four screws to become a complete mounting bracket Thread wire through downrod with canopy and yoke cover assembled onto downrod Tighten both yoke set screws to fur ther secure downrod Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the