1. Owner s Manual Ceiling Fan Installation Instructions Total fan weight For 5DH52 Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO o Quality Ceiling fans LISTED Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan bl
2. ades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent war
3. before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 If using an optional Ceiling Fan Light Kit check to be sure the screws securing the glassware are finger tight Check to be sure light bulb is tight in socket and not touching glass shade s If vibration persists from glass remove glass and install a 1 4 wide rubber band on glass neck to act as an insulator Replace glass and tighten screws against rubber band 6 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Figure 1 Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer
4. ning device such as a tag to the service panel TOOLS REQUIRED Phillips Screwdriver Wire Cutters Pliers Step Ladder Before installing this fan make sure the outlet box is properly installed to the house structure Before you begin installing the fan Switch power off z y a p To reduce the risk of fire electric shock or per at Service panel and lock service disconnecting means Unpack and inspect fan carefully to be certain all contents are included See exploded view parts list D f NE Outlet Box Mounting Plate Install mounting plate to outlet box in ceiling using the two 8 32 screws and washers provided with the outlet box to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Remove two screws 180 degrees apart on mounting plate and save for later use Loosen remaining two screws sonal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs a loose box will cause the fan to wobble Hang motor from hook on the mounting plate Use one of the closed hole CANADIAN MOUNTING SYSTEM INSERT Thread the safety cable thru the mounting Hang motor from hook on mounting plate Use plate Insert one of the 3 lag screws and flat While fan and mounting plate are hanging from one closed holes Pr
5. not supplied between the blade and blade holder at the screw closest to the motor Figure 2 To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Figure 2 Reverse the position of the washer if blades mount from top of blade 6 1f blade wobble is still noticeable interchanging two adjacent side by side blades can redis tribute the weight and possibly result in smoother operation 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
6. oceed to step 7 of normal washer thru the loop in the end of the safety the safety cable install the mounting plate to installation cable Install the lag screw directly to the house the outlet box using the two screws provided structure wooden beam with the junction box CANADIAN SAFETY TIPS WARNING MOUNT ONLY TO AN OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT All set screws must be checked and retightened where necessary before installation Installation Note After installation please refer to operation maintenance and troubleshooting sections in this manual If your fan is packaged with a light kit or if you wish to install a separately purchased light kit please refer to the insert sheet titled Light Kit Installation Standard wiring opti ion House Fan Black W _ Black 77 Blue White White Ground NEX Attach blue wire only if attaching light kit with fan Green Downrod cH XXXXXI Green Bracket Secure with twist lock wire connectors included For pullchain controls follow diagram above Make sure that all exposed wiring is secured inside wire nuts Note Wires from house may vary in color and may not include ground wire After wiring is conplete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips Lift decorative motor housing to slide over Control Light Switch Fan Switch For cont
7. rol of fan and optional light from wall location follow diagram above NOTE A pro fessional electrician is recommended for this type of installation Wrench Mounting Motor Bracket Lift motor into place aligning studs on mounting plate with holes on the motor bracket Install and tighten four locking nuts to studs Tighten firmly Use 7 16 wrench or pliers Install the screws removed in step 5 and tighten all screws mounting plate align with the two remaining screws in the mounting plate with the L shape holes and twist clockwise to lock Attach blade brackets to blades using the blade bracket screws and washers provided Shipping stabilizer tab Remove plastic shipping stabilizer tabs from motor if present The screws washers and motor pads are pre installed to the blade hold ers Attach blade assembly to motor by tighten ing first screw one turn then tighten second screw securely Then go back and tighten first screw securely After attaching blade reinstall the switch hous ing using the three screws previously removed Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in ins
8. tallation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag TROUBLE 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles Blade Tip Up Fan Blade 5 Figure 2 4 If light does not work to the service panel SUGGESTED REMEDY 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency 4 Make sure forward reverse switch is firmly in up or down position Fan will not operate when switch is in the middle CAUTION Make sure main power is turned off 5 Make sure that shipping stabilizer tabs have been removed from motor see step 13 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off

Download Pdf Manuals

image

Related Search

Related Contents

PROTIL STADE - Gamme peintures  1016_catalogo Fast  Corsair 1024MB Server Memory Module PC-2700 333MHz DDR    CMS Mobility Inc dba Summit DME 12919 Southwest  NAVIGON 83xx  DFI CA63-SC Motherboard  GUIDE DE TERRAIN HB3344-02 POUR TUFFTM  製品に起因する事故ではないと判断する案件(PDF形式:615KB)  Stundienarbeit Echolink Interface (Echolink-Box)  