Mityvac MV5545 User's Manual
Contents
1. 28 29 and 30 At this location the fuel pressure and flow measured by the tester will most accurately represent the conditions within the fuel rail Due to some engine compartment layouts and connector locations it may be necessary to connect the tester directly after the in line fuel filter which may be located in the engine compartment under the frame or near the fuel tank In this case be sure to carefully inspect the fuel supply line between the tester and fuel rail for any irregularities such as leaks crimps or kinks as these may cause a false diagnosis based on the tester readings Fig 28 4 at a Le Alternative Connection Locations Connecting the FST inline as instructed above for the initial test ensures the most accurate fuel system diagnosis However in some instances it may be beneficial to connect the tester at alternative locations in order to more accurately pinpoint the exact cause of a malfunction Performing additional diagnostics at different connection locations is detailed in the Testing and Diagnostics section of this manual Selecting and Installing Adapters The FST Pro includes adapters for connecting the tester inline with the fuel delivery systems of a wide variety of US European and Asian manufactured cars and light trucks In most cases making an inline connection with the FST requires two adapters one to connect the fuel line from the fuel tank to the FST inlet and the second to connect the
2. connect tools may be required Fig 34 WARNING Avoid spilling fuel on hot engine parts Clean up any fuel spills immediately after they occur Install the appropriate adapter into the fuel supply line extending from the tank Fig 35 Page Number 20 Tp R pa Fig 31 Fuel Line Connection Location Fig 35 Form 824127 f 10 11 Connect the hose extending from the flowmeter connection labeled IN to the other end of the adapter Fig 36 Install the second FST connection adapter to the fuel line running to the fuel rail If the fuel line connection used by the vehicle man ufacturer is a 3 8 quick connect style SAE J2044 a second adapter is not required Connect the hose extending from the flowmeter connection labeled OUT to the other end of the adapter or directly to the fuel line running to the fuel rail depending on the type of connec tion Fig 37 Before proceeding Double check the connections The tester should be installed such that the fuel flowing from the tank to the engine enters the FST through the port labeled IN out of the tester through the port labeled OUT and on to the fuel rail Route and secure the clear pressure relief and bypass hoses into an approved gasoline container Route the flowmeter inlet and outlet fuel hoses away from rotating engine components belts fans and hot exhaust components Remove the fuel spillage rags Reconnect compon
3. Refer to the Testing and Diagnostics section later in this manual for the proper application of the FST in diagnosing each system In some cases pinpointing the exact cause of the malfunction may be irrelevant because the pump filter and pressure regulator are all part of a module assembly that must be replaced as a complete unit In tank Filtering In tank Return Fig 23 This method involves filtering and returning the excess fuel without it leaving the tank Fig 23 Both pressure regulator and filter are part of the fuel pump module Filtering is accomplished in one of three ways e A pre pump filter is used to filter the fuel before it enters the pump e The filter is located after the pressure regulator where it filters the unused fuel before mixing it back into the fuel reserve e The filter is located in the pump module between the pump and the regulator Some manufacturers have designed in tank filter regulator systems that use some variation or combination of these three concepts to produce what they consider to be the most effective system In cases involving in tank filtering and return all of the control components are included as part of the pump module assembly and are most likely replaced as a complete unit Fig 24 External Filtering In tank Return This system of fuel filtration and return uses a pressure regulator on the pump module to regulate fuel pressure and return unused fuel before it leaves the tank The m
4. This allows the pump to output its maximum flow the value of which can be read on the flowmeter The free flow output of a typical fuel pump is between 7 and 1 0 GPM 2 5 and 4 LPM NOTE Turning the valve to the full BYPASS position will prevent fuel from flowing to the engine If left in the BYPASS position for too long the engine will stall If this happens simply return the valve to the OPEN position and restart the vehicle After noting the peak pressure return the flow control valve to the OPEN position and proceed to the capability test Peak Demand Test 8 Note the vehicle s engine size and maximum engine speed RPM Refer to the Maximum Engine Fuel Volume Requirements table Appendix A and use the size and speed values to determine the maximum fuel volume requirement of the engine Form 824127 Fig 51 Fig 53 Page Number 29 9 With the car idling rotate the flow control valve past the 90 CLOSED position towards BYPASS Fig 54 Adjust the valve until the flowmeter indicates an amount of fuel flow equivalent to the value for the maximum engine fuel volume taken from the table Fig 55 10 Note the pressure reading on the gauge 11 After noting the capability pressure return the flow control valve to the OPEN position Testing is complete Diagnosing the Results The values for four critical fuel system performance indicators should have been noted while following the procedures and perfo
5. a leaking injector s Disconnecting the FST The FST Pro contains features and components to safely disconnect with a minimal release of fuel Follow the procedures below and always observe the safety precautions listed in the front of this manu al Carefully read the warning below concerning disconnecting from a hot returnless fuel system 1 When vehicle testing is completed turn off engine and relieve pressure on the fuel system by pressing the pressure relief valve located on the stem of the pressure gauge Fig 56 Watch the pressure gauge readings and fuel being released through the small clear hose to the collecting container The flow control valve must remain in the OPEN position during pressure relief When fuel pressure is not shown on the gauge and fuel stops flowing through the relief hose proceed to step 3 Place shop towels under the connections to capture any fuel that may spill out when the hoses are disconnected Using the two scissor hose clamps supplied in the FST Pro kit clamp both of the connecting hoses near the end where they con nect to the vehicles fuel system Fig 57 Lock them securely to prevent fuel from leaking out of the tester when the hoses are dis connected WARNING After testing a returnless fuel system use extreme caution when disconnecting the outlet hose connecting the FST to the fuel rail If the engine is hot releasing the pressure from a returnless fuel system will cause the fuel
6. a malfunc tion Blocked Inline Fuel Filter If the inline filter is clean pressure and flow in Zones 1 and 2 should be equal A clogged filter will cause the pressure to increase in Zone 1 and the flow to decrease in Zone 2 If the results of testing in Zone 2 indicate a blocked fuel filter but are not entirely conclusive retest the fuel system with the FST connected in Zone 1 preferably at the inlet of the fuel filter If the idle pressure and the peak flow in Zone 1 are higher than Zone 2 replace the inline fuel filter and retest If the idle pressure and peak flow in Zone 1 remain the same as Zone 2 this would indicate a clogged inlet strainer sock Clogged Inlet Strainer Sock The test results for pressure and flow of a clogged inlet strainer will closely match those of a clogged inline filter The peak pressure of a clogged inlet strainer will be slightly lower than the peak pressure of a clogged inline filter and the current draw will also be lower A clogged inlet strainer can cause the fuel pump to cavitate because it is starved for fuel Cavitation will create rapid changes in fuel densi ty causing the float in the FST flowmeter to bounce up and down It can also cause the needle on the pressure gauge to bounce Also as the pump tries to pull gas through the clogged strainer it creates a pressure drop that may cause air bubbles to form and become visi ble These indications of a clogged inlet strainer may or may not
7. dto eue ELSE ada 11 Diagnosing Fuel Delivery Systems ooooococoooocoooo 11 Simulating Engine Demand llllllllelelsess 12 Pinpointing Fuel System Malfunctions 13 Types of Fuel Delivery Systems n annann annann eee eee ees 14 Return Fuel Systems 0 0 cc cece eee eee eens 14 Returnless Fuel Systems lille 14 Mechanically Regulated 00 0 c eee eee ee eee 15 In tank Filtering In tank Return 000 eee eee 15 External Filtering In tank Return o oo o ooooooooo 15 External Filtering External Return oooooooooo 15 Electronically Regulated 0 0 eee eee 16 Identifying Fuel Delivery Systems 0 00 c cece eee eee 16 Fuel System Components aanne nannan nanan 17 Fel TANK oc curs uci omen ado ene wad ete tee adig ews 17 FUSINPUMD ra Sth ts cas a os are m 17 Fuel Inlet Strainer SOCK 00 17 aM Nude TC 18 Pressure Regulator llle nns 18 PUCKLINGS sve P 18 Setup and Installation ce eee eee 19 Determining Where to Install the FST 19 Inline Connection ias qe o ood es ox Rob aes aC eee ewe ee 19 Alternative Connection Locati0NS 0 o oooooooooo 19 Selecting and Installing Adapters ooooooooo o 19 Setting up the FST Pro sc ea E ede dE RC Ree Ra AD eue 20 Installing the ES
8. install it with any component such as a fuel filter or pressure regulator located between it and the fuel rail Doing so will likely cause the readings to deviate from the pres sure and flow that the engine is experiencing thus reducing the accuracy and the reliability of the test results Diagnosing Fuel Delivery Systems Upon proper installation of the FST and vehicle startup see Setup and Installation the value for fuel pressure at idle will be indicated on the pressure gauge and the volume of fuel flowing to the engine will be displayed by the flowmeter NOTE While normal operating specifications for pressure and flow will vary between vehicle makes models years and engines it is most likely that fuel pressure is the only one for which a documented specification is available Regardless of the vehicle s type of fuel delivery system see Modern Fuel Delivery Systems the idle pressure can immediately be noted and compared to the manufacturer s specification However the idle flow will vary significantly depending on whether the fuel delivery system is return or returnless Assuming the fuel delivery system is operating properly the indicated flow of a return system will represent the total volume the pump is capable of producing at the specified pressure On the other hand the indicated flow of a returnless system will represent only what the engine is using at idle Chances are this volume is so low that it will not even reg
9. of the pump The manufacturer s service manual should document this in their fuel system diagnostic procedure Fuel pumps fail or fail to perform due to high mileage contaminated fuel or electrical problems While there is no fix for wear due to high mileage fuel and electrical problems can be identified corrected and prevented In the case of fuel contamination it is almost certain the pump will have to be replaced due to irreversible damage However electrical issues such as a loose ground bad connection or low voltage can many times be corrected before the pump experiences any permanent damage Contaminated fuel is a major cause of fuel pump failures Dirt debris and scale can clog the inlet strainer and fuel filter causing the pump to work harder and reduce its life They also wreak havoc inside the pump by acting like an abrasive to grind at parts Chemical contaminates can cause precision made components to swell or gum up leading to under performance or complete failure For all of these reasons fuel tanks should be completely drained and professionally cleaned or possibly even replaced each time a fuel pump is replaced or contamination is suspected Check all electrical connections When electrical connections fail voltage to the pump will be reduced causing the pump to run inefficiently and ultimately reducing its life Check the vehicle harness plugs for soot or burned wires Check the pump module hanger plug for me
10. on the pressure or flow of fuel A clogged filter becomes a restriction to flow As blockage in the filter increases flow decreases Depending on the type of fuel delivery system and the level of restriction a clogged fuel filter will cause pressure to increase between the pump and the filter and or decrease between the filter and the fuel rail Because fuel systems are designed to deliver a greater volume and pressure than the engine will require small blockages may not be noticeable However as the restriction increases it will cause the engine to under perform and or stall or hesitate under load In addition it causes the fuel pump to work harder which can lead to premature failure The FST Pro can accurately diagnose a clogged fuel filter by comparing flow and pressure levels at idle with those at simulated load conditions Pressure Regulator The pressure regulator is a component of mechanically regulated fuel delivery systems It creates and maintains the pressure required by the fuel injectors to perform at their optimum efficiency While it s the fuel pump that creates the flow of fuel it s the regulator that creates the pressure by restricting the flow The pressure regulator uses a spring to control the amount of restriction based on the pressure in the fuel system When the engine is off and there is no flow of fuel the regulator spring completely closes the restriction trapping pressure in the fuel rail When the engine
11. one or more of these can cause the system to fail or under perform The function of the FST is to diagnose when a fuel system failure has occurred and to pinpoint the component s which caused the failure To reach an accurate diagnosis a basic knowledge of the fuel system components and their role in achieving optimum engine performance is helpful Following is a list of common compo nents that contribute to the function of the fuel delivery system A failure of one or more of these components can typically be diagnosed using the FST Pro e Fuel Tank e Fuel Pump e Fuel Pump Inlet Strainer Sock e Inline Fuel Filter e Pressure Regulator e Fuel Lines Fuel Tank The fuel tank serves as a reservoir to store the fuel until it is needed by the engine Fuel tanks have been manufactured from a variety of metals and plastics The fuel pump hangs down into the tank drawing the fuel from very close to the bottom The most likely influences of the fuel tank towards a fuel system fail ure would be the result of rust or scale produced by a metallic tank the collection of impurities introduced from the outside or a dented tank that interferes with the function of the fuel pump It is critical that the fuel tank be emptied cleaned and inspected any time a fuel pump is replaced or impurities are suspected Fuel Pump The fuel pump is the heart of the fuel delivery system It pumps fuel from a vehicle s fuel tank to the engine where it is m
12. ple speed pump a scanner must be used to operate the pump at high speed while the vehicle idles NOTE Insufficient pressure and flow are an indication that a fuel pump is under performing but do not necessarily mean that it is fail ing Low voltage or a bad connection or ground will cause a pump to under perform producing the same test results as if the pump were bad Before replacing any fuel pump based on the FST test results always follow the vehicle manufacturer s recommended procedure for testing all electrical connections and the electrical system charge A minor issue such as a loose ground can cause many problems that resemble more serious malfunctions Form 824127 Page Number 25 Returnless Fuel Delivery Systems Mechanically Regulated At this point it is assumed that the FST has been properly installed inline with the fuel delivery system as recommended and that it has been primed to ensure no leaks are present See FST Pro Setup and Installation The following procedure will ensure the most effective diagnostic use of the FST Test Procedure Operational Test 1 Check the operating position of the flow control valve on the side of the flowmeter to ensure the knob is in the OPEN position point ing down Fig 45 This will allow normal fuel system operation 2 Start the car and allow it to idle Cranking or starting the engine should activate the ECM s electric fuel pump controls to turn on and run the fue
13. size flex hose adapter 1 4 5 16 or 3 8 and install it onto the steel fuel line Fig 15 Secure it with one of the wing screw clamps provided Fig 16 5 Follow normal testing procedures Proper Use Care and Servicing With proper care and maintenance the FST Pro will provide years of accurate reliable service The FST is designed for use in testing modern fuel delivery systems on vehicles equipped with gasoline powered combustion engines e CAUTION DO NOT USE THE FST PRO ON DIESEL SYSTEMS e CAUTION DO NOT USE THE FST PRO ON VEHICLES OPERATING ON ALTERNATIVE FUELS SUCH AS E85 OR OTHER FLEX FUELS e Always drain the fuel from the FST prior to storage e Always disassemble the FST and return it to the storage case in which it was originally purchased e Inspect components regularly for damage and replace or repair as necessary Check hoses for cracks and cuts Check adapters for damage and wear to threads and sealing surfaces Check female quick connects for wear and cuts to o rings Inspect the male and female quick connect components where the pressure gauge connects to the flowmeter e After installing the FST and pressurizing the fuel system check the flowmeter for leaks If any leaks are evident immediately relieve the pressure disconnect the FST and send it to a service center for repair Page Number 10 Form 824127 Principle of Operation Fuel Delivery Basics Modern fuel inj
14. the cause of the malfunction NOTE The flow of fuel passing through the tester represents only what the engine is using at idle It will be negligible and most likely not even register on the flowmeter Flow Demand Test 5 With the car idling rotate the flow control valve past the CLOSED position to the BYPASS position pointing up Fig 47 With the valve in the BYPASS position the flow of fuel is routed through the bypass port located above the valve through the bypass hose and into the reservoir All restriction to the flow of fuel is removed This allows the pump to output its maximum flow the value of which can be read on the flowmeter The free flow output of a typical fuel pump is between 7 and 1 0 GPM 2 5 and Fig 47 4 LPM NOTE Turning the valve to the CLOSED or BYPASS position will prevent fuel from flowing to the engine If left in either of these positions for too long the engine will stall If this happens simply return the valve to the OPEN position and restart the vehicle 6 After noting the peak flow return the flow control valve to the Page Number 26 Form 824127 OPEN position Peak Demand Test 7 Note the vehicle s engine size and maximum engine speed RPM Refer to the Maximum Engine Fuel Volume Requirements table Appendix A and use the size and speed values to determine the maximum fuel volume requirement of the engine 8 With the car idling rotate the flow control valve past the 90 CL
15. to boil in the fuel rail Even though the pressure has been released the boiling fuel will cause it to build up again once the hose is clamped To reduce the risk of fuel spray it is best to allow the engine to cool before disconnecting the hose Otherwise use the FST pressure relief valve to relieve the pressure just before clamping the hose Once Page Number 32 Fig 56 Fig 57 Form 824127 the hose is clamped quickly disconnect the hose from the fuel system before the pressure has time to build Try to keep a shop towel wrapped around the connection to catch any fuel spray 4 Rotate the flow control valve to the CLOSED position to help pre vent fuel leakage 5 With the scissor clamps locked in place on the connecting hoses disconnect the FST adapters and fitting connectors from the vehi cle s fuel system Fig 58 6 Reconnect the vehicle fuel lines and check for possible fuel con nection leaks before starting the engine Fig 59 Cycling the igni tion ON and OFF without starting the engine will run the fuel pump briefly to prime the fuel system on most vehicles Always check fuel line connections to ensure they are securely fastened and do not leak 7 Place the disconnected ends of the connection hoses into an approved fuel container with the bypass and pressure relief hoses Drain fuel from the FST flowmeter gauge and hoses by releasing the scissor clamps Rotate the flow control valve and press the pres
16. 0 Banjo Adapter M10 x 1 0 Banjo Adapter M12 x 1 25 Banjo Adapter M12 x 1 5 Banjo Adapter M12 x 1 5 Ball Nose Adapter M14 x 1 5 Ball Nose Adapter Fuel System Test Adapters Applications GM amp some Chrysler vehicles with 74s x 20 thread test port on fuel rail Ford amp some Chrysler vehicles with 308 x 32 thread test port on fuel rail GM amp some Chrysler vehicles with 74s x 20 thread test port on fuel rail Ford amp some Chrysler vehicles with 308 x 32 thread test port on fuel rail GM Chrysler Jeep Eagle Vehicles with 7 Yes or rubber to steel hose connection Vehicles with 1 4 rubber to steel hose connection Vehicles with 5s rubber to steel hose connection Vehicles with rubber to steel hose connection Toyota Lexus Geo Honda Acura Hyundai Mazda Daihatsu Chrysler imports Audi Volkswagen European vehicles with CIS fuel system European vehicles with CIS fuel system MVAS05 Reference NO O NO zx Co are O co 16A 16B 16C 13B 13A 14B 14A 15B 15A 9A 12A 12B 10A 10B Not included in MV5545 Available individually or in MVA5552 Pressure Test Accessory Kit Form 824127 Fuel System Test Adapters _ NN M16 x 1 5 European vehicles Ball Nose Adapter with CIS fuel system ne M16 x 1 5 Adapter GM Vortec MVA520 M14 x 1 25 Adapter GM Vortec MVA521 4 Flare Nut Adapter Carbureted amp ear
17. 000 7X 9x as os os os os os om eo o 3 e en es 29 es w 3e 3e owe 2m 29 29 es m o3 o 38 o9 2 29 sor gt eo a 3 39 es 29 34 39 Values for maximum engine fuel volume requirements are calculated based on 10096 engine efficiency Many factors can affect engine performance such that no engine may perform at 100 efficiency These values are to serve as reference only Form 824127 Page Number 35 Appendix B Return Fuel System Diagnostic Guide R l Idi bids 5 ce Peak Pressure Peak Flow Potential Causes Scenario Pressure reater than T 50 to maximum fuel to 1 0 GPM Fuel system is operat Normal Normal Normal 100 higher Normal volume require 2 5 to 4 0 LPM ing normally than spec ment se ias 5096 to Blocked fuel filter inlet Normal to mum fuel vol Less than 7 i l Normal 100 higher Low strainer or pinched slightly low ume require GPM 2 5 LPM ment than spec supply line 0 Greater than 7 Normal Me n er Kenma to 1 0 GPM Under restricting GPM 2 5 LPM o Ig 2 5 to 4 0 LPM pressure regulator than spec Less than maxi 5096 to u mum fuel vol to 1 0 GPM _ Over restricting pres l Normal 100 higher Normal ume require 2 5 to 4 0 LPM sure regulator ment than spec Less than maxi mU dd Low 50 higher Low mui insufficient power than spec Less than Failing fuel pump or ume requir
18. 0s Since that date other car manufacturers have been implementing returnless systems onto their cars Now returnless systems are common on most all new cars and light trucks Mechanically Regulated In the case of mechanically regulated returnless systems the term returnless can be misleading Like a return system the fuel pump operates continuously producing an uncontrolled output Since the engine will only use a portion of the total pump output the excess fuel must still be returned This is done either in the tank or the fuel is routed just outside the tank for filtering and then returned Mechanically regulated systems utilize a spring operated pressure regulator mounted in the tank as part of the pump module The regu lator is very similar to those used in return systems except it is not vacuum or pressure modulated Fuel pressure in returnless systems is typically higher than return systems to compensate for the lack of modulation and to help prevent the fuel from boiling in the fuel rail Mechanically regulated returnless fuel systems employ one of three basic concepts to filter the fuel and accommodate the excess output of the pump All three methods utilize a fuel pump module with built in pressure regulator The FST is very capable of diagnosing a malfunction of any of the three variations However the type of return filtration method employed has a significant impact on the FST s capability to pinpoint the malfunction
19. 179 Storage Case Accessories Part Number Description MVA500 Low Pressure Gauge MVA501 Flowmeter Faceplate 0 to 60 Gallons Hour includes front and back plate MVA5549 MotorVac Adapter Set MVA5552 Pressure Test Accessory Kit MVA506 Inline Pressure Test Assembly MVA509 Extended Pressure Test Hose Page Number 4 824149 824148 824144 824173 824142 824179 e MVA5552 MVA5549 MVA509 Form 824127 Service Parts Part Number 1 824182 2 824177 3 824176 D al 824175 824174 O 824146 T 824145 824183 824181 824180 824178 824182 4 824178 824175 OO OO DIO 824145 Form 824127 Description Flow Tube Shield Male Quick Connect Fitting Bypass Port Flow Control Valve Knob Flowmeter Inlet Outlet Connector Qty 2 Flow Control Valve Flowmeter Seal Kit Wing Style Hose Clamp Qty 4 Flowmeter Boot Adapter O Ring Kit Ford Springlok Tether with Clip 824181 824177 AAA Na Am A 824174 824183 824176 y A 824146 CM f iii Page Number 5 Page Number 6 Description GM Chrysler Right Angle Test Port Adapter Ford Chrysler Right Angle Test Port Adapter GM Chrysler Test Port Adapter Ford Chrysler Test Port Adapter Y Quick change Adapter Ya Y Barbed Flex Hose Adapter Ya Flex Hose Adapter 6 Flex Hose Adapter Y Flex Hose Adapter M8 x 1
20. FST outlet to fuel line continuing on to the engine The FST utilizes female 3 8 SAE J2044 quick connectors on the ends of the inlet and outlet hoses that connect into the fuel line This Fig 29 is the same connection that is used on many newer makes and mod els of cars If the vehicle being tested uses this adapter style only one intermediate adapter will be required This should be evident upon inspection of the vehicle s connection All of the adapters included with the FST have an identification num ber stamped into them for easy identification To determine an adapter s size and application s use its number to locate it in the Adapter Application Chart on page 6 and 7 Most of the adapters and their connection methods are straight for ward Simply match the FST test adapter to the type of fuel line con nection used on the vehicle All adapters should thread or snap together easily to form a leak proof seal Always err on the side of caution If the connection has to be forced or if there is looseness in the connection do not attempt to pressurize the system Contact the Mityvac technical service department at the number on the front of this manual if there are any questions or concerns about the connec tion Fig 30 If you have access to the fuel system adapters manufactured by MotorVac for their CarbonClean fuel system cleaner these may be utilized with the FST Pro Mityvac model MVA5549 MotorVac Adapter Kit is
21. OSED position towards BYPASS Fig 48 Adjust the valve until the flowmeter indicates an amount of fuel flow equivalent to the value for the maximum engine fuel volume taken from the table Fig 49 9 Note the pressure reading on the gauge 10 After noting the capability pressure return the flow control valve to the OPEN position Testing is complete Diagnosing the Results The values for three critical fuel system performance indicators should have been noted while following the procedures and performing the tests outlined above e Idle Pressure e Peak Bypass Flow e Peak Demand Pressure These indicators are the key to properly diagnosing a malfunctioning fuel delivery system and pinpointing the cause Compare the three values to the Returnless mechanically regulated Fuel System Diagnostics Chart Appendix C If according to the chart the FST test values indicate a normal operating fuel delivery system then the engine is receiving the proper pressure and flow of Maximum fuel fuel even under maximum load conditions If the FST indicates a nor volume mal operating fuel delivery system yet the vehicle continues to expe requirement rience symptoms of a fuel delivery malfunction it could be caused by Appendix A contaminated fuel faulty fuel injector s or an intermittent component malfunction such as a sticking pressure regulator or loose electrical connection If the FST test results are inconclusive as to wheth
22. SIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE In no event shall Lincoln be liable for incidental or consequential damages Lincoln s liability for any claim for loss or damages arising out of the sale resale or use of any Lincoln equipment shall in no event exceed the purchase price Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages therefore the above limitation or exclusion may not apply to you This warranty gives you specific legal rights You may also have other rights that vary by jurisdiction Customers not located in the Western Hemisphere or East Asia Please contact Lincoln GmbH amp Co KG Walldorf Germany for your warranty rights Lincoln Industrial Contact Information To find Lincoln Industrial s Nearest Service Center call the following numbers or you may also use our website Customer Service 314 679 4200 Website lincolnindustrial com Americas Europe Africa Asia Pacific One Lincoln Way Heinrich Hertz Str 2 8 25 Int l Business Park St Louis MO 63120 1578 D 69183 Walldorf 401 65 German Centre USA Germany Singapore 609916 Phone 1 314 679 4200 Phone 49 6227 33 0 Phone 65 562 7960 Fax 1 800 424 5359 Fax 49 6227 33 259 Fax 65 562 9967 Copyright 2007 www lincolnindustrial com Printed in Taiwan Page Number 42 Form 824127
23. ST flowmeter Fig 32 Installing the FST Pro 1 Be sure the vehicle transmission in park or neutral the parking brake is applied and the engine is off Follow the vehicle manufacturer s recommended procedure to relieve the pressure from the vehicle fuel delivery system Locate the fuel supply line to the engine s fuel rail and select the best location to disconnect the supply line and install the FST Fig 33 If uncertain of the proper connection point see the previous section entitled Determining Where to Install the FST For additional assistance consult the vehicle manufacturer s service information or refer to the Types of Fuel Delivery Systems section earlier in this manual If the engine has a cover it will most likely have to be removed to gain appropriate access Remove or disconnect any obstacles required to gain access to the connection and place shop towels under and around the connection to absorb fuel from the disconnected line To minimize fuel spillage and reduce the amount of time the fuel line is disconnected try to identify the type of connection before disconnecting the fuel line and have the required FST connection adapter s readily available see Selecting and Installing Adapters above Also identify the inlet and outlet hoses to the tester and keep them convenient Follow the vehicle manufacturer s service information for the prop er method to disconnect the fuel line Special wrenches or dis
24. T Pro vic ys de onde E a doe tale a tos 20 Testing and Diagnostic VR aora 22 Return Fuel SystelriS s dada Ca a dada Ra 22 Returnless Fuel Systems Mechanical 26 Returnless Fuel Systems Electronic o 28 Fuel VISUALIZATIONS s asta das ic dos ped ile 31 Pressure Leakdown Test 0 cece eee eee eee teens 31 Disconnecting the FST et E RE AR 32 PACU OIA wee c o oia 34 APPEN A O EN 36 SA A O ce dU 38 APPS att a A AA AA 40 Watson had nan oe T ae ye Ae ee 42 Page Number 2 Form 824127 Introduction The Mityvac FST Pro Fuel System Tester is an advanced diagnostic tool designed for troubleshooting and pinpointing common automotive fuel delivery system malfunctions including e Failing fuel pump e Faulty pressure regulator e Blocked inline filter e Blocked inlet strainer sock e Pinched or crushed fuel line e Fuel contamination e Fuel tank vortex e Fuel system leaks This manual focuses on the application of the FST to modern electronic fuel injection EFI systems However it is equally capable of diagnosing earlier fuel injection systems such as throttle body injection TBI continuous injection CIS and even pre fuel injection carbureted systems A separate low pressure gauge is available from Mityvac for systems that operate below 15 PSI 100 kPa Safety Precautions The use of this service tool requires the exposure of highly flammable gasoline To preve
25. Under restricting pressure regulator Over restricting pressure regulator Failing fuel pump or insufficient power supply Return Filtration Methods for Mechanically Regulated Returnless Fuel Systems Fuel Supply Line Fuel Filter Method 1 In Tank Filtering In Tank Return Page Number 38 e Fuel Filter Pressure Regulator Fuel Rail Fuel Pump Method 2 External Filtering In Tank Return Inlet Strainer Sock M Fuel Return Method 3 External Filtering External Return Form 824127 Appendix C Returnless Mechanically Regulated Fuel System Diagnostic Guide Scenario 2 Diagnosis A restriction to the supply of fuel to the engine such as a clogged inlet screen inline filter or pinched fuel supply line will reduce the flow of fuel This will be evident by the reduction in peak flow Idle pressure will remain normal or drop only 1 or 2 psi below spec Capability pressure will be low depending on the amount of restriction and the type of return filtration method used Additional Action Inspect the fuel supply line for damage If the return filtration method is type 1 or 2 connect FST between fuel tank and inline filter and retest If peak flow is normal replace inline filter If flow is still low replace inlet screen sock Scenario 3 Diagnosis Low idle and capability pressure combined with normal peak flow is a sure indication of an under restricting pressure regulator S
26. ain filtration is handled by an inline filter mounted externally between the tank and the fuel rail Fig 24 External Filtering External Return In this type of filtering return system the fuel is pumped out of the tank to an external filter mounted on or near the tank Fig 25 The fil ter serves as a sort of manifold with a single fuel supply line running into one end of the filter and two fuel lines exiting the filter One of the exiting lines supplies fuel to the engine while the other returns the unused fuel to the regulator and the tank Fig 25 Form 824127 Fuel Filter Fuel Supply Line Fuel Rail M Fuel Filter Pressure Regulator Fuel Pump Inlet Strainer Sock M Fuel Return Page Number 15 Electronically Regulated Fuel Filter Evel Supply Line Ford began developing an electronically regulated returnless fuel Pressure Test Port delivery system in the late nineties and began implementing it on Pump Module their cars in the early to mid 2000s This system shares some of the Sr features and benefits of both return and returnless systems but with FUE El the addition of advanced control technology The two main differ ences of an electronically regulated fuel system are the replacement i Pressure of the mechanical pressure regulator with an electronic pressure Sensan sensor and the introduction of a variable speed fuel pump Fig 26 The fuel pressure sensor is moun
27. ak pressure would remain within spec An under restricting pressure regulator would produce a higher than normal idle flow and low idle pressure but normal values for peak flow and peak pressure Noting the values of these test indicators and comparing them to the vehicle s specifications the technician can in most cases accurately pinpoint the cause of a malfunction Testing a returnless system will generate performance measurements for Idle Pressure Peak Flow and Peak Demand Pressure The values for these indicators are applied in the same way to pinpoint the cause of a fuel system malfunction This logic can be applied to all components that can influence fuel delivery system performance The details of this method are documented in the Testing and Diagnostic section of this manual Form 824127 Page Number 13 Types of Fuel Delivery Systems For the purpose of accurately applying and testing with the FST Pro today s fuel delivery systems can be divided into three typical configurations e Return Bypass Fuel Systems e Returnless Fuel Systems Mechanically Regulated e Returnless Fuel Systems Electronically Regulated The fundamental differences between return and returnless fuel systems affect the values for pressure and flow displayed by the FST and influence its diagnostic capabilities Even the differences between mechanically and electronically regulated returnless systems produce substantially varying resu
28. available to make this conversion NOTE In many cases it may only be possible to identify the type of connection after the fuel line has been disconnected However to Form 824127 Page Number 19 reduce fuel spillage whenever possible try to select the required adapters before disconnecting the fuel line and have them ready to install Setting up the FST Pro Once the installation point has been determined follow the instruc tions below to setup the tester prior to disconnecting the fuel line 1 Place the vehicle transmission in park or neutral apply the parking brake and turn the key off Hang the pressure gauge under the vehicle hood or other appro priate location Connect the flowmeter to the pressure gauge using the female push to connect coupler extending from the bottom of gauge and the male connector located on top of the flowmeter Make sure the quick connect sleeve snaps forward to lock the connec tion NOTE The flowmeter should hang vertically for the most accurate fuel flow measurement Connect the 1 8 3 mm clear pressure relief hose to the barb extending from the push button pressure relief valve located just under the gauge Fig 31 Place the free ends of the bypass hose and pressure relief hose into an approved gasoline fuel container Secure hoses in fuel container as necessary to prevent spills Connect one end of each 3 8 inlet and outlet connection hoses to the bottom fittings on the F
29. be evi dent during testing If the results are inconclusive retest the fuel sys tem with the FST connected in Zone 1 preferably at the inlet of the fuel filter If the idle pressure and peak flow in Zone 1 remain the same as Zone 2 this would indicate a clogged inlet strainer sock Replace the strainer or the pump module and retest Page Number 24 Zone 2 Blue lt Zone 1 Red Zone 3 Yellow Form 824127 Under restricting Fuel Pressure Regulator An under restricting pressure regulator will cause the idle pressure in Zones 1 and 2 to drop below spec and the idle flow to be higher than normal If this is what the FST is indicating and the peak pressure and flow are normal then the cause is most certainly the pressure regulator If the fuel pressure regulator is vacuum modulated see Fuel System Components Pressure Regulator it is possible to check if it is stick ing by disconnecting the vacuum line If the regulator is functioning properly disconnecting the vacuum line should cause the fuel pres sure to increase Over restricting Fuel Pressure Regulator If Zone 2 testing indicates idle pressure is high and flow is low yet peak pressure and flow are normal this is a clear indication of an over restriction in Zone 3 Over restriction can be caused by a mal functioning fuel pressure regulator or blockage in the return fuel line Perform a careful visual inspection of the fuel return line to ensure
30. cenario 4 Diagnosis High idle and capability pressure combined with normal peak flow is a sure indication of an over restricting pressure regulator Scenario 5 Diagnosis Low values for all three indicators are an indication that the output of the fuel pump is not adequate Additional Action Verify that the vehicle is not using a multiple speed pump If so a scanner must be used to operate the pump at its highest speed Before replacing pump follow the vehicle manufacturer s proper procedure to check for low voltage or a bad connection or ground Form 824127 Page Number 39 Appendix D Returnless Electronically Regulated Fuel System Diagnostic Guide Results Scenario Pressure Normal Peak Demand Pressure Less than 1096 below idle pressure Greater than 1096 below idle pressure Greater than 1096 below idle pressure Less than maximum fuel volume Peak Pressure 5096 to 10096 higher than spec 5096 to 10096 higher than spec 5096 to 10096 higher than spec 50 to Peak Flow Normal Normal to 1 0 GPM 2 5 to 4 0 LPM Less than 7 GPM 2 5 LPM to 1 0 GPM 2 5 to 4 0 LPM Potential Causes Fuel system is operating normally Blocked fuel filter inlet strainer or pinched supply line Electronic control l to 1 0 GPM failure failing fuel 0 eae righ 2 5 to 4 0 LPM pump or insufficient x than spec requirement power supply Less than 50 highe
31. d capability tests should clearly indicate a pump problem If the FST indicates a pump is under performing be sure to verify that the vehicle does not use a multiple speed pump see Fuel System Components Fuel Pumps To properly test a fuel system with a multi ple speed pump a scanner must be used to operate the pump at high speed while the vehicle idles NOTE Insufficient pressure and flow are an indication that a fuel pump is under performing but do not necessarily mean that it is fail ing Low voltage or a bad connection or ground will cause a pump to under perform producing the same test results as if the pump were bad Before replacing any fuel pump based on the FST test results always follow the vehicle manufacturer s recommended procedure for testing all electrical connections and the electrical system charge A minor issue such as a loose ground can cause many problems that resemble more serious malfunctions Returnless Fuel Delivery Systems Electronically Regulated At this point it is assumed that the FST has been properly installed inline with the fuel delivery system as recommended and that it has been primed to ensure no leaks are present see FST Pro Setup and Installation The following procedure will ensure the most effective diagnostic use of the FST Operational Test 1 Check the operating position of the flow control valve on the side of the flowmeter to ensure the knob is in the OPEN position point ing dow
32. e O to 120 PSI 0 to 8 bar 0 to 800 kPa scale of measure Push button pressure relief valve 360 swivel hook Protective rubber boot e Flowmeter Assembly Borosilicate glass variable area flowtube with protective shield and precision aluminum float 3 way Flow Control Valve Fuel bypass port Male push to connect quick change coupler w Schrader valve 2x Male SAE J2044 quick connects Replaceable faceplates with O to 1 0 gallon minute scale of measurement Protective rubber boot e 2x Replaceable flowmeter faceplates with O to 4 liters minute scale of measurement e 1 8 3 mm ID x 6 1 8 m long Pressure Relief Hose e 1 4 6 5 mm ID x 6 1 8 m long Bypass Hose e 2x Flowmeter Connection Hose e 2x Scissor Hose Clamp e 2x Hose Plug e 6x Quick connect Replacement Clip e Custom Storage Case e Automotive Fuel System Test Adapters see Fuel System Test Adapters on page 6 Page Number 3 Standard Kit Components Part Number Description 824141 High Pressure Gauge 824149 Pressure Relief Hose 1 8 3mm ID x 6 1 8 m long 824148 Bypass Hose 1 4 6 5 mm ID x 6 1 8 m long 824144 Scissor Hose Clamps Qty 2 824147 Flowmeter Hose 3 8 9 5 mm ID x 4 1 2 m long 824173 Hose Plug Qty 2 824143 Flowmeter Faceplates Liters Minute includes front and back plate 824142 Flowmeter Faceplates Gallons Minute includes front and back plate 824172 Quick connect Replacement Clips Qty 6 824
33. e ment GPM 2 5 LPM iy See Appendix A for maximum engine fuel volume requirement To manifold vacuum Pressure Regulator ali ld SS S Fuel Rail Fuel Supply Line C Fuel Filter Fuel return line Inlet strainer sock Fuel Pump Page Number 36 Form 824127 Appendix B Return Fuel System Diagnostic Guide Scenario 2 Diagnosis A restriction to the supply of fuel to the engine such as a clogged inlet strainer inline filter or pinched fuel supply line will reduce the flow of fuel However pressure will remain normal or drop only 1 or 2 psi below spec If the flow at idle is less than the calculated maximum fuel volume requirement then the engine will be starved of fuel in a heavy load condition such as wide open throttle Additional Action Inspect the fuel supply line for damage Connect FST between fuel tank and inline filter and retest If flow is normal replace inline filter If flow is still low replace inlet strainer sock Scenario 3 Diagnosis High flow and low pressure at idle are a sure indication of an under restricting pressure regulator If values for peak pressure and flow remain normal replace the pressure regulator Scenario 4 Diagnosis High pressure and low flow at idle indicates too much restriction in the path of the fuel as it returns from the fuel rail to the fuel tank The cause can be an over restricting pressure regulator or pinched return line Additional Actio
34. e the clamp from the fuel line and restart the engine to build pressure Form 824127 Page Number 31 Turn off the engine and immediately clamp off the FST inlet hose running to the tester from the fuel supply line This will trap the pressure gauge between the clamp the fuel rail the pressure reg ulator and the fuel return line If the pressure drops either the injectors or the pressure regulator is leaking With the second scissor clamp pinch off the fuel return line between the pressure regulator and the fuel tank If the pressure continues to drop the cause is a leaking injector s If the pressure holds steady the cause is a leaking pressure regu lator Returnless Fuel Systems 1 2 6 Start the engine to build pressure Turn off the engine and immediately clamp off the FST outlet hose running from the tester to the fuel rail This will trap the pressure gauge between the clamp and the fuel pump module If the pressure gauge indicates a leak check the fuel supply line from the tank to the tester If no leaks are evident replace the fuel pump module due to a faulty pump check valve or leaking regula tor Remove the clamp from the fuel line and restart the engine to build pressure Turn off the engine and immediately clamp off the FST inlet hose running to the tester from the fuel supply line This will trap the pressure gauge between the clamp and the fuel rail If the pressure drops the cause is
35. e unattended while testing e Check and secure all fuel system connections before starting the vehicle or activating the fuel pump Form 824127 e Wear gloves and protective clothing to avoid the contact of gasoline on skin If contact occurs immediately wash the area and perform necessary first aid e Always keep a fire extinguisher on hand when performing fuel related diagnostics Make sure the extinguisher is rated for fuel electrical and chemical fires e Avoid spilling fuel on hot engine parts Clean up any fuel spills immediately after they occur Specifications Maximum Flow Capacity 1 0 gallon minute 3 8 liters minute Maximum Rated Pressure 200 PSI 1340 kPa 13 8 bar Components Service Parts and Accessories The Mityvac FST Pro combines the highest quality materials and workmanship to create a durable finely tuned diagnostic tool which with proper care will provide years of valuable service All components are designed and quality controlled in the U S Following is a list of standard components service parts and accessories relating to model MV5545 Components and accessories are available from your local Mityvac distributor Service parts warranty information and technical service information are available at the contact information shown on the front of this user manual Standard Kit Components Model MV5545 includes the following high quality components e 3 5 90 mm diameter diaphragm style Pressure Gaug
36. ected engines rely on precision fuel delivery to perform at peak output and efficiency It is the function of the fuel delivery system to ensure that proper fuel pressure and volume are present in the fuel rail to meet the demands of the engine under varying operating conditions When a fuel delivery system is designed to meet a particular vehicle s requirements a fuel pump is selected that can deliver at least the maximum fuel pressure and volume requirement of the engine Other components of the fuel delivery system act upon the output of the fuel pump to ensure the fuel pressure at the injectors is maintained at the predetermined specification The maximum volume of fuel required by an engine varies depending on its size For example an 8 0 liter engine running at 3 000 rpm could consume as much as 34 gallons of fuel per minute while a 1 8 liter engine at the same speed would use only 08 gallons per minute When manufacturers design a fuel delivery system for a specific engine they consider the fuel requirements based on the size expected load and speed This data is used to program the vehicle s Electronic Control Module ECM which in turn controls the opening and closing duty cycle of the fuel injectors With the exception of emerging electronically controlled fuel injection systems the ECM assumes that fuel pressure and volume to the engine are maintained according to the designer s specifications If a malfunction in the fuel deliv
37. ents such as PCV tubes wiring harnesses vacuum tubes etc that were disconnected to gain access to the fuel line connection Check the operating position of the flow control valve on the side of the flowmeter Ensure it is in the OPEN position pointing down Fig 38 Re enable the fuel pump if previously disabled and cycle the ignition switch to the ON position for a brief time and then back OFF Do not start the engine On most vehicles cycling the ignition ON and OFF will allow the fuel pump to run briefly and prime the tester After cycling the ignition check all fuel connections for leaks If all fitting connec tions are secure the installation is complete and the FST Pro is ready to be used for diagnostic tests Form 824127 Fig 37 Fig 38 Page Number 21 Testing and Diagnostics Testing and diagnostic procedures vary depending on the type of fuel delivery system Prior to testing the fuel delivery system must be identified as Return Returnless mechanically regulated or Returnless electronically regulated For detailed information on fuel delivery sys tems and how to identify them refer to the section entitled Types of Fuel Delivery Systems earlier in this manual If the fuel system is a return or mechanically regulated returnless system it must also be determined if the fuel pump has multiple speeds For more informa tion on types of fuel pumps refer to Fuel System Components Fuel Pump in th
38. er there is a fuel delivery system malfunction or if a malfunction is evident but the diagnostic chart does not clearly indicate the cause additional testing may be performed to provide more insight into the performance of the system Extended test procedures are outlined below and provide a more in depth understanding of how the components of the fuel sys tem affect its performance Additional Testing and Diagnostics Blocked Inline Fuel Filter Not all mechanically regulated returnless fuel systems utilize an exter nally mounted fuel filter see Types of Fuel Delivery Systems Mechanically Regulated If the vehicle has an accessible fuel filter and initial test results indicate it may be partially blocked retest the fuel system with the FST connected at the inlet of the fuel filter If the peak flow and peak demand pressure are higher then in the initial test replace the fuel filter and retest If the peak flow and peak demand pressure remain the same this would indicate a clogged inlet strainer sock Clogged Inlet Strainer Sock The test results for pressure and flow of a clogged inlet strainer will closely match those of a clogged inline filter The peak demand pres sure of a clogged inlet strainer will be slightly lower than that of a clogged inline filter and the current draw will also be lower Form 824127 Fig 49 Page Number 27 A clogged inlet strainer can cause the fuel pump to cavitate because it is starved for
39. ery system such as a blocked filter faulty pressure regulator or bad fuel pump causes pressure or flow to vary at the fuel rail the ECM cannot directly sense this The only way the ECM can recognize a fuel related problem exists is through the O2 sensor in the exhaust The O2 sensor alerts the ECM if the exhaust mixture is rich or lean The ECM can only respond by opening the injectors for longer or shorter time periods to inject more or less fuel This may be enough to mask small problems from the driver but will result in poor fuel efficiency If the vehicle owner does not notice a decrease in efficiency and have the vehicle serviced eventually the malfunction will lead to greater drivability problems To help compensate for small fuel delivery problems such as a partially clogged filter manufacturers build a safety factor into the fuel system so that it is capable of supplying somewhat greater fuel pressure and volume than the engine will ever require Because of this if a fuel delivery system is malfunctioning enough to cause a noticeable drivability problem with the aid of the FST Pro a technician should be able to accurately diagnose and pinpoint the cause of the problem Application of the FST The function of the FST Pro is to e Inform technicians that there is a malfunction in the fuel delivery system preventing the engine from receiving the optimal fuel pressure and flow it requires to perform at peak efficiency and perf
40. formance using other feedbacks such as the O2 sensor and controlling fuel injector duty cycle Mechanically regulated returnless fuel delivery systems use a constant pressure regulator located in the fuel tank as part of the fuel pump module It maintains constant pressure due to a fixed spring rate Fuel pressures in returnless systems are typically higher than return systems to compensate for the lack of modulation When diagnosing a potential pressure regulator failure consider what happens in the fuel delivery system when the regulator fails to maintain the proper fuel pressure If the regulator sticks in the open position such that there is little or no restriction to flow fuel will flow freely through the regulator and back to the fuel tank Fuel system pressure may drop drastically below what is required by the injectors Depending on how the low the pressure drops the malfunction may not be noticeable when the car is idling or running under a minimal load But if a heavy load condition is introduced on the engine such as a hard acceleration the lack of pressure will cause the engine to stumble and lack power If the sticking regulator was over restricting the flow of fuel back to the tank it would cause fuel system pressure to increase above normal Because the fuel pump produces much greater flow than what the engine will typically require this malfunction may not be evident at idle or at minimal load conditions However f
41. fuel Cavitation will create rapid changes in fuel densi ty causing the float in the FST flowmeter to bounce up and down during the peak flow and or capability test It can also cause the nee dle on the pressure gauge to bounce In addition as the pump tries to pull gas through the clogged strainer it creates a pressure drop that may cause air bubbles to form and become visible These indications of a clogged inlet strainer may or may not be evi dent during testing If the results are inconclusive and the fuel system has an accessible inline filter follow the procedure above to rule out a clogged filter If it is determined that the inline filter is not the problem replace the strainer or the pump module and retest Over or Under restricting Pressure Regulator Because mechanically regulated returnless fuel systems incorporate the pressure regulator into the fuel pump module it is not possible to perform additional on car testing to determine if the pressure regula tor is malfunctioning If the pressure regulator and or fuel pump is replaceable within the module the FST test results may be beneficial in determining how to approach a repair Fuel Pump Malfunction A malfunction at the fuel pump is typically indicated by a reduction in both pressure and flow At idle the regulator may be able to maintain pressure in the system but the pressure will drop as soon as the engine requires a greater volume of fuel Performing flow demand an
42. gallons per minute GPM Included with the kit are faceplates with a liters minute LPM flow scale Faceplates printed with a gallons per hour GPH flow rate scale can be purchased separately The faceplates are held securely by the lip of the rubber boot that surrounds the flowmeter For accuracy they pilot on the caps that seal the top and bottom of the flowtube To remove the faceplates simply peel back the edges of the rubber boot To install new faceplates match the replacement faceplate to the correct side of the flowmeter position the cutout over the flow tube and then carefully work the lip of the rubber boot back over the edge Connections The hoses that route fuel from the vehicle s fuel delivery system into and out of the FST Pro utilize a special female quick connect fitting Fig 5 This fitting was selected for several important reasons 1 It conforms to the SAE J2044 specification for fuel fittings 2 Itis a common fuel delivery system connection on which many manufacturers are standardizing 3 It does not restrict fuel flow which could cause a false diagnosis 4 The connection releases with a simple push button action No special tools are required to disconnect the fittings The flowmeter inlet and outlet ports as well as the adapters and fittings that connect the FST into the fuel delivery system have the complimenting male SAE J2044 endform Fig 6 To secure the male to female connection simply p
43. he engine If left in the BYPASS position for too long the engine will stall If this happens simply return the valve to the OPEN position and restart the vehicle Fig 43 10 After noting the peak flow return the flow control valve to the OPEN position Testing is complete Diagnosing the Results The values for four critical fuel system performance indicators should have been noted while following the procedures and performing the tests outlined above e Idle Pressure e Idle Flow e Peak Dead head Pressure e Peak Bypass Flow These indicators are the key to properly diagnosing a malfunctioning fuel delivery system and pinpointing the cause In addition to these values note the vehicle s engine size and maximum engine speed RPM Refer to the Maximum Engine Fuel Volume Requirements table Appendix A and use the size and speed values to determine the maximum fuel volume requirement of the engine Refer to the Return Fuel System Diagnostic Guide Appendix B If according to the chart the FST test values indicate a normal operat ing fuel delivery system then the engine is receiving the proper pres sure and flow of fuel even under maximum load conditions If the FST indicates a normal operating fuel delivery system yet the vehicle Form 824127 Page Number 23 continues to experience symptoms of a fuel delivery malfunction it could be caused by contaminated fuel faulty fuel injector s or an intermittent compo
44. include a washer between the face of the filter or fuel rail and the opposing face of the adapter bolt Fig 11 6 Follow normal testing procedures NOTE Always throw away the original used washers and replace them with new when reconnecting the banjo fitting back to the vehicle s original specification Form 824127 Fig 8 Banjo Fitt Fuel Rail Banjo Bolt Adapter Fig 10 Banjo Adapter TUTE a Closed Banjo Bolt ing ls 4 End Nut Banjo Fitting Fig 11 Fuel Filter Page Number 9 Flex Hose Connections In many cases it is convenient to connect the FST Pro into the fuel delivery system at a location where a flexible rubber hose is secured to a steel fuel line using a screw clamp A special adapter set is included with the FST Pro for installing it into this type of connection It includes a universal barb adapter three flexible hose adapters 1 4 5 16 3 8 and four wing screw clamps To install the flex hose adapters 1 Follow the proper procedure under the Setup and Installation instructions to relieve the fuel pressure and prepare for disconnecting 2 Loosen the screw clamp securing the rubber hose to the steel fuel line on the vehicle s fuel delivery system and carefully disconnect the rubber hose Fig 12 3 Insert the universal barb adapter 16 into the rubber hose Fig 13 and tighten the hose clamp Fig 14 4 Select the appropriate
45. is manual Return Fuel Delivery Systems At this point it is assumed that the FST has been properly installed inline with the fuel delivery system as recommended and that it has been primed to ensure no leaks are present see Setup and Installation The following procedure will ensure the most effective diagnostic use of the FST Test Procedure Operational Test 1 Check the operating position of the flow control valve on the side of the flowmeter to ensure the knob is in the OPEN position point ing down Fig 39 This will allow normal fuel system operation 2 Start the car and allow it to idle Cranking or starting the engine should activate the ECM s electric fuel pump controls to turn on and run the fuel pump If the fuel pump does not operate refer to the vehicle service information for electrical diagnosis and repair of the fuel pump and associated controls After connecting the FST it is normal to have air trapped in the fuel lines and flowmeter Cycling the ignition switch or cranking the engine briefly with the flow control valve in the BYPASS posi tion can help purge air from the system Once fuel fills the flowmeter and flows through the bypass hose return the valve to the OPEN position The bypass hose must be routed and secured into an approved fuel container before operating the flow control valve in BYPASS mode To perform an accurate diagnosis using the FST the car must be running in order to provide the co
46. is started the restriction causes the pressure to increase in front of the regulator When fuel system pressure builds to the optimum level it overcomes the force of the regulator spring and the regulator opens to allow fuel to flow through As the fuel requirements of the engine differ from idle the regulator automatically increases or decreases the restriction to maintain the optimum pressure at the injectors Pressure regulators used in return type fuel systems are mounted on the fuel rail and are either vacuum or atmospheric modulated Vacuum modulated pressure regulators use manifold vacuum to maintain a constant pressure differential across the fuel injectors This means that fuel rail pressure will vary depending on manifold vacuum At idle manifold vacuum is Page Number 18 high This causes the regulator to pass more fuel back to the tank lowering fuel pressure in the rail When the throttle is opened manifold pressure drops This causes the regulator to close allowing less fuel flow back to the tank so fuel rail pressure increases Vacuum modulation ensures the injectors are receiving the proper fuel pressure for peak engine performance depending on the engine s requirements Atmospheric modulated pressure regulators modify fuel pressure with changes in atmospheric pressure This allows fuel systems to compensate for changes in altitude Atmospheric modulated fuel systems rely more on the ECM to control fuel injection per
47. ister on the flowmeter Page Number 11 In regards to return fuel systems knowing the pressure and flow at idle is a very good indication as to whether the fuel system is functioning properly However while pressure can be compared to a manufacturer s spec idle flow is not typically documented Most return fuel systems will flow around 5 gallons 2 liters per minute at idle However the idle flow may range from 3 to 7 GPM 1 1 to 2 6 LPM depending on the vehicle make model year and engine Under a heavy load a 5 0 liter engine may require as much 5 GPM 2 LPM while a 2 0 liter engine may only require 2 GPM 75 LPM Any return fuel system flowing less than 3 GPM at idle should be considered suspect for a malfunction Due to flow variances additional testing described below will provide a more accurate diagnosis of fuel system performance Using the FST to test a returnless system at idle will provide a measurement for idle pressure However flow at idle will provide no additional insight as to its peak performance capability Using the patented flow control valve on the FST to execute simple pressure and flow demand tests is required for an accurate diagnosis Simulating Engine Demand At idle an engine requires very little fuel and places very little demand on the fuel delivery system A typical fuel pump is capable of providing up to 30X more fuel than an engine requires at idle Testing a fuel delivery system at idle
48. it s not crushed dented or kinked If damage or restriction is noted repair the line and retest Inspect the fuel pressure regulator for physical damage Also look for dampness that could indicate a ruptured diaphragm that is leaking fuel Replace and retest if necessary If the pressure regulator is vacuum modulated use a vacuum gauge to verify the vacuum reading at the regulator A below normal vacuum reading would cause the regulator to over restrict the flow Follow the vehicle manufacturer s procedure for locating and repairing the cause of the vacuum loss and retest If vacuum is normal connect the FST in Zone 3 preferably right after the pressure regulator Test the fuel system at this point and compare the results to Zone 2 The pressure in Zone 3 should be very low If it remains high there is a restriction in the fuel return line If the pressure drops off to near zero then replace the fuel pressure regulator Fuel Pump Malfunction A malfunction at the fuel pump is typically indicated by a reduction in both pressure and flow At idle the regulator may be able to maintain pressure in Zones 1 and 2 but doing so will severely reduce the flow Performing pressure and flow demand tests should clearly indicate a pump problem If the FST indicates a pump is under performing be sure to verify that the vehicle does not use a multiple speed pump see Fuel System Components Fuel Pump To properly test a fuel system with a multi
49. ixed with air and injected into the cylinders for burning Fuel pumps in most modern fuel delivery systems are located inside the fuel tank and run on electricity supplied by the vehicle s electrical system They pump a continuous volume of fuel at a given voltage and are typically extremely reliable when operated under the conditions for which they are designed Despite their reliability and the high cost and hazard of replacement fuel pumps have a higher return rate than almost any other automotive part They are commonly misdiagnosed and needlessly replaced costing consumers repair shops and manufacturers millions of dollars each year It s estimated that 80 or more of returned pumps are found to function properly when tested by the manufacturer Most mechanically regulated fuel delivery systems operate the fuel pump at one speed based on a constant voltage from the electrical system However some automotive manufacturers have begun incorporating two or three speed pumps to improve efficiency and reduce emissions Like electronically regulated returnless systems the speed of the pump is controlled by the ECM However the ECM does not increase pump speed based on fuel pressure In such a case the fuel pump may not increase speed output in reaction to the simulated load method used by the FST Instead a scanner or manufacturer s software is required to manually increase the speed in order to test the Form 824127 peak capability
50. l pump If the fuel pump does not operate refer to the vehicle service information for electrical diagnosis and repair of the fuel pump and associated controls Fig 45 After connecting the FST it is normal to have air trapped in the fuel lines and flowmeter Cycling the ignition switch or cranking the engine briefly with the flow control valve in the BYPASS posi tion can help purge air from the system Once fuel fills the flowmeter and flows through the bypass hose return the valve to the OPEN position The bypass hose must be routed and secured into an approved fuel container before operating the flow control valve in BYPASS mode To perform an accurate diagnosis using the FST the car must be running in order to provide the correct operating voltage to the fuel pump Testing the fuel system by activating the fuel pump using a scan tool will cause the fuel pump to severely under per form 3 If the vehicle utilizes a multiple speed fuel pump use a scanner or manufacturer s recommended procedure to operate the pump at the highest speed 4 Note the fuel system pressure indicated on the pressure gauge and compare it with the vehicle manufacturer s specification Fig 46 If it is out of spec this is an indication of a problem with one or more components of the fuel system However performing a Flow Demand Test and Capability Test as outlined below are required to reach an accurate diagnosis of the fuel system and to pinpoint
51. ll have two lines one supplying fuel from Atmosphere the tank the second returning the unused fuel back to the tank It is easy to confuse fuel lines with lines for the evaporative system so inspect them closely Fuel lines will be either steel or fuel rated rubber Fuel Return Line Return systems will have a pressure regulator typically mounted on the end of the fuel rail such that unused fuel flows out of the fuel rail through the pressure regulator and into the return line The pressure regulator will typically have a vacuum line attached which adjusts fuel pressure regulation according to engine speed Fig 27 Some cars will have a pulse dampener which can be easily confused with the regulator The pulse damper is typically found on returnless systems It does not have a vacuum line attached to it and is com monly mounted at the inlet or extends from the side of the fuel rail Returnless fuel systems will have a single fuel line running to the fuel rail There will be no fuel pressure regulator located at the fuel rail Fuel Supply Line i Fig 27 Electronically controlled fuel systems will have a pressure transducer mounted on the fuel rail see Fuel System Components The transducer will have an obvious electrical connection with three to five wires extending from it Page Number 16 Form 824127 Fuel System Components The modern fuel delivery system is comprised of several critical components A malfunction of
52. lted plastic or loose terminals on the flange Perform a voltage drop test across all electrical connec tors and all electrical components involved with the fuel pump Also check the wires from the pump to the flange when replacing a pump only application A damaged wiring harness if not repaired may cause a premature failure to a replacement pump Each component of the fuel delivery system has its own unique affect on pressure and flow when it malfunctions When a fuel pump is failing or under performing its total output declines causing both flow and pressure to drop When testing a vehicle s fuel delivery system with the FST Pro the affects of an under performing pump can be diagnosed by observing how pressure and flow respond to simulated load conditions Other common test methods such as testing amperage draw or pressure alone can not reliably detect a malfunction and or do not have the capability to simulate a load condition This combined with a lack of fuel delivery system knowledge and training leads to the high rate of misdiagnosis Fuel Inlet Strainer Sock Fuel flows from the tank through an inlet strainer sock before entering the fuel pump It is designed to capture dirt and debris that could damage the pump Because it is not easily accessi ble it is large in size so that it should not have to be replaced except when the pump is serviced or replaced If the inlet strainer becomes clogged or plugged it will limit the a
53. lter and or the fuel rail Often this will be the best place to connect the FST inline with the fuel system This type of connection may be a little confusing the first time it is encountered A banjo connection consists of a round hollowed out banjo connector with two flat sides A hollow bolt with a cross hole passes through the banjo connector and threads into the connecting component i e filter fuel rail When the bolt is tightened it creates a secure face to face seal through which the fuel flows See Fig 9 for an illustration of this connection Two 2 threaded adapters and a closed end nut are required to properly install the FST into a banjo style connection Refer to the adapter chart for a list of the banjo adapters included with the FST To install the banjo adapters 1 Follow the proper procedure under the Setup and Installation instructions to relieve the fuel pressure and prepare for disconnecting 2 Loosen and remove the bolt from the banjo connection at the fuel filter or fuel rail 3 Pass the hollow adapter with the cross hole through the banjo fitting Be sure to include a washer on both sides of the banjo fitting Fig 10 4 Thread the closed end nut onto the end of the bolt and tighten securely with a wrench trapping the banjo fitting 5 Thread the hollow bolt adapter without the cross hole into the filter or fuel rail in place of the original bolt and tighten securely with a wrench Be sure to
54. lts The key to achieving the most accurate fuel system diagnosis begins with a basic understanding of the differ ences between fuel systems and how the FST responds to each Return Fuel Systems In a return type of fuel system a continuous volume of fuel is pumped to the engine via the fuel supply line The engine uses what it needs and the rest is returned back to the tank via the fuel return line Fig 21 The fuel pump receives power directly from the electrical system Pump speed is not controlled by any external source so when the system is functioning properly it outputs a constant flow Fuel pressure in a return system is created by a pressure regulator mounted at the exit point of the fuel rail or fuel return line As the unused fuel leaves the fuel rail it passes through the regulator which restricts the volume of the returning fuel see Fuel System Components Pressure Regulator This causes backpressure to build up in the fuel rail and fuel supply line all the way back to the fuel pump This backpressure is the pressure at which fuel is delivered to the injectors and what is referred to by the vehicle manufacturer s specification for proper fuel pressure An inline filter is installed in the fuel supply line between the fuel pump and the fuel rail to filter out impurities before they reach the injectors It s typically mounted under the frame or in the engine bay making it relatively easy to replace A properly fu
55. ly MVA522 EN fuel injected systems ES e Flare Nut Adapter a s 2 3 Spring Lock Adapter Ford fuel injection systems 1 Spring Lock Adapter Ford fuel injection systems 16 Quick Change Adapter GM Chrysler Jeep Eagle Form 824127 Page Number 7 N 1 1 3 4 5 2 O 1A 1B 3A B 4A B 6A 5A B 7A 7B 8A 8B B 2A Assembly For flexibility and ease of storage the FST Pro features a modular design that is quick to assemble and breakdown Proper assembly for testing is covered in the Setup and Installation instructions Bypass Hose Prior to the first use of the FST the 1 4 6 5 mm ID clear bypass hose should be assembled to the bypass port extending from the side of the flowmeter above the flow control valve To connect the fuel bypass hose 1 Unscrew the compression nut from the fuel bypass port extending from the side of the flowmeter just above the flow control valve Fig 1 2 Slip the compression nut over one end of the clear bypass hose 1 4 6 5 mm ID x 6 1 8 m long Fig 2 3 Push the end of the bypass hose over the barb extending from the bypass port Fig 3 4 Slide the compression nut up over the end of the tube and thread it back onto the bypass port Tighten the nut using a 7 16 open end wrench Fig 4 Flowmeter Faceplates The flowmeter is shipped with faceplates installed on the front and back The flow scale unit of measure printed on both plates is
56. manufacturer s recommended procedure for troubleshooting these components to determine the malfunction Form 824127 Page Number 41 Lincoln Industrial Standard Warranty LIMITED WARRANTY Lincoln warrants the equipment manufactured and supplied by Lincoln to be free from defects in material and workmanship for a period of one 1 year following the date of purchase excluding therefrom any special extended or limited warranty published by Lincoln If equipment is determined to be defective during this warranty period it will be repaired or replaced within Lincoln s sole discretion without charge This warranty is conditioned upon the determination of a Lincoln authorized representative that the equipment is defective To obtain repair or replacement you must ship the equipment transportation charges prepaid with proof of purchase to a Lincoln Authorized Warranty and Service Center within the warranty period This warranty is extended to the original retail purchaser only This warranty does not apply to equipment damaged from accident overload abuse misuse negligence faulty installation or abrasive or corrosive material equipment that has been altered or equipment repaired by anyone not authorized by Lincoln This warranty applies only to equipment installed operated and maintained in strict accordance with the written specifications and recommendations provided by Lincoln or its authorized field personnel THIS WARRANTY IS EXCLU
57. may be acceptable if the driver has no intention of actually driving the car but what happens when a driver needs to accelerate or commit to a driving condition that places a load on the engine The key to determining if a fuel delivery system can meet maximum engine requirements is to test it under the engine s most demanding conditions Using patented technology the FST Pro is the only tester Fig 18 capable of simulating demand on a vehicle s fuel delivery system to determine if it can meet the peak requirements of the engine The FST has a built in flow control valve that enables an operator to manually vary the flow restriction such that it simulates a car s throttle position from idle all the way to wide open The flow control valve is located on the side of the FST flowmeter assembly Arrows on the faceplate and rubber boot illustrate the three positions of the valve as OPEN CLOSED and BYPASS When the valve is in the OPEN position pointing down fuel flows normally through the tester without affecting the normal operation of the fuel delivery system Fig 18 On a return system 3 to 5 GPM of flow is typical while a returnless system will indicated little to no flow Fuel pressure should read within the manufacture s specification regardless of the type of fuel system When the valve is rotated 90 to the CLOSED position flow through the FST is completed restricted Fig 19 On a return system or elec tronicall
58. mount of fuel flowing to the fuel system to the point that it will starve the engine of adequate pressure and volume This can create drivability problems In addition a clogged strainer makes the fuel pump work harder to pull fuel through it and can starve the pump of fuel that it needs for lubrication and cooling All of these factors can lead to premature pump failure Page Number 17 A clogged inlet strainer can starve the fuel pump of fuel causing it to cavitate Cavitation will create rapid changes in fuel density causing the float in the FST flowmeter to bounce up and down It can also cause the needle on the pressure gauge to bounce In addition as the pump tries to pull gas through the clogged strainer it creates a pressure drop that may cause air bubbles to form and become visible Always inspect the inlet strainer whenever a fuel pump is being serviced If it is rusty brown or dark colored proper action must be taken to clean and service the tank Never reuse old filters or strainers especially when installing a new fuel pump Fuel Filter Fuel filters ensure that the fuel sent to the injectors is clean They are installed in the fuel supply line such that fuel flows from the tank through the filter on its way to the fuel rail Filters are typically mounted under the car along the frame or in the engine bay where they are relatively accessible for periodic replacement A clean filter should have little or no affect
59. n Inspect the fuel return line for damage If the regulator is vacuum modulated check the level of vacuum at the regulator If it is low repair the cause Connect the FST after the pressure regulator and retest If pressure remains high the return line is restricted If it drops off to near zero replace the pressure regulator Scenario 5 Diagnosis Low values for idle and peak pressure and flow are an indication that the output of the fuel pump is not adequate Additional Action Verify that the vehicle is not using a multiple speed pump If so a scanner must be used to operate the pump at its highest speed Before replacing pump follow the vehicle manufacturer s proper procedure to check for low voltage or a bad connection or ground Form 824127 Page Number 37 Appendix C Returnless mechanically regulated Fuel System Diagnostic Guide Results Scenario v Pressure Normal Normal s Rid 2 5 to 4 0 LPM Normal T Less than 7 GPM 2 5 LPM T T to 1 0 GPM 2 5 to 4 0 LPM to 1 0 GPM Less than 7 GPM 2 5 LPM Low Low Peak Demand Pressure Normal Low Less than 1096 below idle pressure Greater than 1096 below idle pressure Greater than 1096 below manufacturer s specification Above manufacturer s specification Greater than 1096 below manufacturer s specification Potential Causes Fuel system is operating normally Blocked fuel filter inlet strainer or supply line
60. n Fig 50 This will allow normal fuel system operation 2 Start the car and allow it to idle Cranking or starting the engine should activate the ECM s electric fuel pump controls to turn on and run the fuel pump If the fuel pump does not operate refer to the vehicle service information for electrical diagnosis and repair of the fuel pump and associated controls Page Number 28 Fig 50 Form 824127 After connecting the FST it is normal to have air trapped in the fuel lines and flowmeter Cycling the ignition switch or cranking the engine briefly with the flow control valve in the BYPASS posi tion can help purge air from the system Once fuel fills the flowmeter and flows through the bypass hose return the valve to the OPEN position The bypass hose must be routed and secured into an approved fuel container before operating the flow control valve in BYPASS mode To perform an accurate diagnosis using the FST the car must be running in order to provide the correct operating voltage to the fuel pump Testing the fuel system by activating the fuel pump using a scan tool will cause the fuel pump to severely under per form Note the fuel system pressure indicated on the pressure gauge and compare it with the vehicle manufacturer s specification Fig 51 Typical electronic fuel injection system pressures range from 30 to 60 PSI 205 to 410 kpa depending on the vehicle being tested Always use the recommended vehicle
61. nctioning return type system will always deliver a much greater volume of fuel to the engine than what it will require even under a heavy load or a wide open throttle WOT condition A normally functioning return fuel system will continuously circulate around 5 gallon 2 liters of gas per minute at normal operating pressure Ultimately the fuel system designer determines what the flow will be based on the engine requirements but it will typically vary between the 3 and 7 GPM depending on engine size Due to its layout and the location of critical components return systems are the most easily and accurately diagnosed by the FST When installed and operated as recommended the FST can measure four 4 critical values that combine to precisely diagnose the fuel system and pinpoint any malfunctions Returnless Fuel Systems The term returnless describes fuel delivery systems that do not return unused fuel back to the tank once it has entered the fuel rail The fuel rail becomes the end of the line where fuel pumped from the tank remains under pressure until it s used by the engine Fig 22 Page Number 14 Fuel Filter Pressure Test Port Fuel Supply Line Pressure Fuel Return Inlet Strainer Regulator Line Fig 21 Fuel Filter Pressure Test Port Fuel Supply Line Fuel Rail Pressure Regulator Inlet Strainer Fig 22 Form 824127 Returnless fuel systems mechanically regulated were pioneered by Chrysler in the mid 9
62. nent malfunction such as a sticking pressure regu lator or loose electrical connection Follow the vehicle manufacturer s recommended procedures for the inspection and repair of these com ponents If the FST test results indicate a fuel delivery system malfunction and the diagnostic chart clearly pinpoints the cause follow the vehicle manufacturer s repair procedures to correct the malfunction After performing the repairs re test the fuel delivery system with the FST to ensure it is operating normally If the FST test results are inconclusive as to whether there is a fuel delivery system malfunction or if a malfunction is evident but the diagnostic chart does not clearly indicate the cause additional testing may be performed to provide more insight into the performance of the system Extended test procedures are outlined below and provide a more in depth understanding of how the components of the fuel sys tem affect its performance Additional Testing and Diagnostics To perform more in depth diagnostics consider the fuel delivery sys tem split into three zones as shown in figure 44 The initial test proce dures outlined above are performed in Zone 2 because the fuel pres sure and flow within this zone most accurately represent the condi tions present in the fuel rail Depending on the suspected component malfunction connecting the FST in either Zone 1 or Zone 3 and com paring the test results to those in Zone 2 can help pinpoint
63. nit amp FST PRO FUEL SYSTEM TESTER UVEC MODEL MV5545 USER S MANUAL Have a technical question If you have questions or require technical service please contact our trained service technicians at 1 314 679 4200 ext 4782 Monday Friday 7 30 am to 4 15 pm CST Visit our website at www mityvac com for new products catalogs and instructions for product use Need service parts To order replacement or service parts visit us online at www mityvacparts com or call toll free 1 800 992 9898 SEPTEMBER 2007 Form 824127 Section MV59 1 Contents INTOCUCHION PTT D nm 3 od ety PIecautioris sinerien A 3 SPECIICAHONS Nie aun c e 3 Components Service Parts and Accessories 3 Standard Kit COMpONentS ocoococcccconc ees 3 4 SEVICE Pals rt a deste daa tas A 5 Fuel System Test AdapterS ooooooccocooccocon o 6 7 ASSEM DNT 2 ais ico i a debidas des 8 BYPASS OSC ira talar cos Cda 8 Flowmeter Faceplates 00 cece eee eee eee eee eee 8 COMMECUONS x 3axtdbtramai hare ve tod Sako Soit Entei wud Sele 8 A dee ds ar adh Sw a ee anon a bes 8 Banjo GONMECHONS aioe ne lude RR o E UR eed ates 9 Flex Hose Connections 000 cece eee eens 10 Proper Use Care and Servicing 00 cece ee eee eee 10 Principle of Operation a n 00 ccc eee eens 11 F el Delivery Basics ieseni na edes bis E Ee de tcn aba Mta 11 Application of the BST a Euer ao
64. nt fires explosions and or severe injury always apply extra precautions when diagnosing or working on fuel systems The FST Pro is designed for servicing a variety of vehicles in a safe convenient manner However fuel delivery systems vary widely between makes and models of vehicles potentially requiring additional steps or equipment to perform a proper service job The procedures outlined in this manual are to serve as guidelines for the use of this equipment In addition to these guidelines always follow the manufacturer s recommended procedures when servicing each unique vehicle Use common sense in the application of this tester and do not attempt to force a test on a fuel system for which this equipment is not designed to perform This tester is designed for use on gasoline petrol engines only It is safe for use with gasoline and most gasoline additives but is not compatible with diesel fuel or alternative flex fuels that contain ethanol e Always read carefully and understand instructions prior to using this equipment e Wear safety glasses at all times e Operate the vehicle only in a well ventilated area and away from potential sources of flame or ignition e Prior to starting an engine make sure all components of the tester body parts and personal clothing are clear of rotating engine components e Avoid burns by remaining cautious of engine parts that may become hot when the engine is running e Never leave a vehicl
65. ogged strainer it creates a pressure drop that may cause air bubbles to form and become visible These indications of a clogged inlet strainer may or may not be evi dent during testing If the results are inconclusive and the fuel system has an accessible inline filter follow the procedure above to rule out a clogged filter If it is determined that the inline filter is not the problem replace the strainer or the pump module and retest Fuel Pump Electronic Control Failure If testing with the FST indicates the engine is not receiving the proper fuel pressure and volume and a clogged inline filter or fuel line are determined not to be the cause then a failure of the electronic control system or the fuel pump is the most likely cause Follow the vehicle manufacturer s recommended procedure for troubleshooting these components to determine the malfunction Once repairs are com plete retest the system for proper fuel delivery system performance Fuel Visualization Visualizing the fuel as it passes through the flowmeter can provide hints of fuel system problems or fuel contamination A rapid drop in pressure possibly caused by a clogged inlet strainer can cause the fuel to boil even at normal temperatures Air released by the fuel forms bubbles that are visible as they pass through the flowmeter Air bubbles can also be caused by a bad swirl pot or leaking fuel pickup line in the tank which allow air to be sucked into the fuel pump Perf
66. ormance e Assist the technician in accurately pinpointing fuel delivery system malfunctions so as to obsolete current confusing time consuming and costly troubleshooting procedures The FST is able to perform these functions by providing real time values for fuel pressure and flow and by allowing Form 824127 the technician to simulate varying load conditions on the engine while the vehicle is idling in the shop These functions are performed by means of a pressure gauge flow gauge flowmeter and a patented flow control valve The FST operates by measuring and acting upon the flow of fuel as it is pumped from the fuel tank to the engine by a vehicle s fuel delivery system To accomplish this the FST is designed to be connected inline with the fuel system such that fuel flows normally through the tester just prior to entering the fuel rail It is critical that the FST be installed as close as possible to and directly inline with the fuel rail so that the pressure and flow measurements most accurately represent the conditions experienced by the engine The further away from the fuel rail that the tester is installed the more likely the chance that an external factor such as a blocked fuel line will affect the accuracy of the test results Figure 17 illustrates a typical instal lation of the FST on a return type fuel delivery system Fig 17 NOTE When conducting an initial evaluation of the fuel system using the FST never
67. orming flow demand tests can sometimes cause air to form in the fuel lines but air bubbles should never be present once the FST is connected air is bled off and fuel is flowing normally to the engine Fuel contaminated with water may appear discolored or cloudy Rust or scale will typically be filtered out before reaching the tester but additives can cause discoloration Don t be fooled by gas that appears normal Many chemical impurities are not visible but can cause the engine to run poorly Pressure Leakdown Test To facilitate hot starts modern fuel delivery systems should maintain some pressure for several hours after the engine is turned off Once the fuel pump is no longer operating the pressure is trapped in the fuel system by a check valve in the fuel pump and closing of the pressure regulator and fuel injectors With the FST connected inline before the fuel rail turn off the engine and watch the pressure gauge If the pressure drops more than 5 psi in 5 minutes a leak exists somewhere in the system Return Fuel Systems 1 Start the engine to build pressure 2 Turn off the engine and immediately clamp off the FST outlet hose running from the tester to the fuel rail This will trap the pressure gauge between the clamp and the fuel pump 3 If the pressure gauge indicates a leak check the fuel supply line from the tank to the tester If no leaks are evident replace the fuel pump due to a faulty check valve 4 Remov
68. r Low than spec Less than maximum fuel volume requirement Less than 7 GPM 2 5 LPM See Appendix A for maximum engine fuel volume requirement Pressure Transducer Sensor Fuel Rail Fuel Filter Fuel Supply Line ECM PCM Inlet strainer sock Fuel Pump Page Number 40 Form 824127 Appendix D Returnless Electronically Regulated Fuel System Diagnostic Guide Scenario 2 Diagnosis A restriction to the supply of fuel to the engine such as a clogged inlet strainer inline filter or pinched fuel supply line will reduce the flow of fuel However idle and peak pressure will remain normal or drop only 1 or 2 psi below manufacturer s specification If the peak flow at idle is less than the calculated maximum fuel volume requirement and the capability pressure is low then the engine will be starved of fuel in a heavy load condition such as wide open throttle Additional Action Inspect the fuel supply line for damage Connect FST between fuel tank and inline filter and retest If the peak flow and capability pressure are normal replace inline filter If still low replace inlet screen sock Scenario 3 4 5 Diagnosis If testing with the FST indicates the engine is not receiving the proper fuel pressure and volume and a clogged inline filter or fuel line are determined not to be the cause then a failure of the electronic control system or the fuel pump is the most likely cause Follow the vehicle
69. ressure Demand Dead head Test 7 With the car idling rotate the flow control valve on the side of the flowmeter towards the 90 CLOSED position Fig 42 Rotating the valve to CLOSED creates a restriction to the flow of fuel through the tester Watch the pressure gauge as the valve is rotated the pressure should increase Note the pressure when the valve is fully closed A good fuel pump should be capable of pro ducing pressure 50 to 100 higher than the rating of the fuel system Fig 42 Caution Never rotate the valve to the closed position for longer than a brief instant This is referred to as dead heading the pump and can cause serious damage to the fuel system or pump 8 After noting the peak pressure rotate the flow control valve back to the OPEN position and proceed to the flow demand test Flow Demand Test 9 With the car idling rotate the flow control valve past the CLOSED position to the BYPASS position pointing up Fig 43 With the valve in the BYPASS position the flow of fuel is routed through the bypass port located above the valve through the bypass hose and into the reservoir All restriction to the flow of fuel is removed This allows the pump to output its maximum flow the value of which can be read on the flowmeter The free flow output of a typical fuel pump is between 7 and 1 0 GPM 2 5 and 4 LPM Note Turning the valve to the full BYPASS position will prevent fuel from flowing to t
70. rformed to provide more insight into the performance of the system Extended test procedures are outlined below and provide a more in depth understanding of how the components of the fuel sys tem affect its performance Additional Testing and Diagnostics Blocked Inline Fuel Filter If the vehicle has an accessible fuel filter and initial test results indi cate it may be partially blocked retest the fuel system with the FST connected between the fuel tank and the filter preferably at the filter inlet If the peak flow and peak demand pressure are higher then in the initial test replace the fuel filter and retest If the peak flow and peak demand pressure remain the same this would indicate a clogged inlet strainer sock Clogged Inlet Strainer Sock The test results for pressure and flow of a clogged inlet strainer will closely match those of a clogged inline filter The peak demand pres sure of a clogged inlet strainer will be slightly lower than that of a clogged inline filter and the current draw will also be lower A clogged inlet strainer can cause the fuel pump to cavitate because it is starved for fuel Cavitation will create rapid changes in fuel densi Page Number 30 Fig 55 Form 824127 ty causing the float in the FST flowmeter to bounce up and down during the peak flow and or capability test It can also cause the nee dle on the pressure gauge to bounce In addition as the pump tries to pull gas through the cl
71. rming the tests outlined above e Idle Pressure e Peak Demand Pressure e Peak Dead head Pressure e Peak Bypass Flow These indicators are the key to properly diagnosing a malfunctioning fuel delivery system and pinpointing the cause Compare the four values to the Returnless electronically regulated Fuel System Diagnostic Chart Appendix D If according to the chart the FST test values indicate a normal operating fuel delivery system then the engine is receiving the proper pressure and flow of fuel even under maximum load conditions If the FST indicates a normal oper ating fuel delivery system yet the vehicle continues to experience symptoms of a fuel delivery malfunction it could be caused by con taminated fuel faulty fuel injector s or electronic control system or an intermittent component malfunction such as a loose electrical con Maximum fuel nection volume If the FST test results indicate a fuel delivery system malfunction and requirement the diagnostic chart clearly pinpoints the cause follow the vehicle Appendix A manufacturer s repair procedures to correct the malfunction After performing the repairs re test the fuel delivery system with the FST to ensure it is operating normally If the FST test results are inconclusive as to whether there is a fuel delivery system malfunction or if a malfunction is evident but the diagnostic chart does not clearly indicate the cause additional testing may be pe
72. rrect operating voltage to the fuel pump Testing the fuel system by activating the fuel pump using a scan tool will cause the fuel pump to severely under per form 3 If the vehicle utilizes a multiple speed fuel pump use a scanner or manufacturer s recommended procedure to operate the pump at the highest speed 4 Note the fuel system pressure indicated on the pressure gauge and compare it with the vehicle manufacturer s specification Fig 40 Typical electronic fuel injection system pressures range from 30 to 60 PSI 205 to 410 kpa depending on the vehicle being tested Always use the recommended vehicle service information proce dures and pressure specifications for the specific vehicle being tested 5 Note the volume of fuel passing through the flowmeter by reading across the top of the float and comparing it to the corresponding value on the scale printed on the faceplate Fig 41 Page Number 22 Read top of float Fig 39 Form 824127 At idle the volume of fuel flowing through the tester should remain steady between 0 3 and 0 6 gallons per minute GPM or 1 1 and 2 2 liters per minute LPM 6 Noting the values for pressure and volume if either is out of range these are indications of a problem with one or more com ponents of the fuel system However performing the Pressure and Flow Demand Tests below is required to reach a more accurate diagnosis and to pinpoint the cause of a malfunction P
73. service information proce dures and pressure specifications for the specific vehicle being tested NOTE The flow of fuel passing through the tester represents only what the engine is using at idle It will be negligible and most likely not even register on the flowmeter Pressure Demand Dead head Test 4 With the car idling rotate the flow control valve on the side of the flowmeter towards the 90 CLOSED position Fig 52 Rotating the valve to CLOSED creates a restriction to the flow of fuel through the tester Watch the pressure gauge as the valve is rotated the pressure should increase Note the pressure when the valve is fully closed A good fuel pump should be capable of pro ducing pressure 5096 to 10096 higher than the rating of the fuel system Caution Never rotate the valve to the closed position for longer than a brief instant This is referred to as dead heading the pump and can cause serious damage to the fuel system or pump After noting the peak pressure rotate the flow control valve back to the OPEN position and proceed to the flow demand test Flow Demand Test 6 With the car idling rotate the flow control valve past the CLOSED f position to the BYPASS position pointing up Fig 53 With the valve in the BYPASS position the flow of fuel is routed through the bypass port located above the valve through the bypass hose and into the reservoir All restriction to the flow of fuel is removed
74. simply rotating the valve between CLOSED and BYPASS By monitoring the corresponding pressure and flow on the FST the fuel delivery system s ultimate capability to meet engine requirements can be determined Although it may sound complicated applying this principle is quite simple For example a 3 8L engine with a maximum speed of 6 000 rpm can require an estimated flow of up to 34 GPM 1 3 LPM of fuel see Appendix A Keeping an eye on the flowmeter the valve should be rotated from the OPEN position past the CLOSED position until the reading across the top of the float is 34 GPM The corresponding pressure value should be noted On a return system or electronically regulated returnless system the pressure value should be higher than the manufacturer s specification On a mechanically regulated returnless system the pressure should be within the manufacturer s specification Pinpointing Fuel System Malfunctions To pinpoint the cause of a fuel system malfunction a simple knowledge of fuel system components and their affect on system Fig 20 performance is combined with the results from the tests above to determine the most likely point of failure For example initial FST testing of a return fuel system would yield values for four critical performance indicators Idle Pressure Idle Flow Peak Pressure and Peak Flow A clogged inline fuel filter would restrict fuel flow causing low values for idle and peak flow but idle and pe
75. sure relief valve as necessary to ensure all fuel is drained from the tester 8 Use the plastic hose plugs supplied in the FST kit to temporarily cap the open ends of the flowmeter connecting hoses Fig 60 9 If testing is complete disassemble and store all components of the FST Pro in the original case Fig 60 Form 824127 Page Number 33 Appendix A Maximum Engine Fuel Volume Requirements Gallons Minute Emmsm O EeSpedRPM O Wes Gb 3x 3x9 sx e 7x 9 3s i os e oor eos 010 ore a2 m o o oo on o om gt 34 s o o oo o os o as ew oo e on 017 9 29 x e em ors e om om ss o os om es os os ss ase os os ee os os 009 so or os os os oe on ea o os os os os oe 076 ss os os os os oe ore gt e m ow o oo oo on om 4 os o os os on os 78 4 oa o os os ow 000 eo os o os on os os Values for maximum engine fuel volume requirements are calculated based on 100 engine efficiency Many factors can affect engine performance such that no engine may perform at 100 efficiency These values are to serve as reference only Page Number 34 Form 824127 Appendix A Maximum Engine Fuel Volume Requirements Liters Minute nese O O EnneSped RPM Wes co 3X 4x sx 6
76. ted directly onto the fuel rail which ensures the most accurate reading of the pressure at the injectors ECM PCM The signal from the pressure sensor is fed to the ECM where it is Fuel combined with other inputs such as from the O2 sensor The ECM Tank processes the data and uses it to control the duty cycle of the injectors and the speed of the fuel pump Fuel pressure and volume are controlled by the ECM speeding up or slowing down the fuel pump This eliminates the need for a pressure regulator Although a whole new level of technology and control has been introduced with this system the engine requirements are still the same The FST is just as effective at diagnosing an electronically regulated system as a mechanical and the test procedures are just as straightforward Identifying Fuel Delivery Systems Begin by opening the hood and locating the fuel rail If the engine has only one bank of cylinders there will be only one fuel rail Engines with two cylinder banks will typically have two fuel rails each feeding the injectors in one of the banks There will be a crossover between the rails to allow fuel to flow from one side to the other Fuel rails vary in appearance from simple round tubes to square or rectangular in shape Look for the fuel line s They typically come up from under the car at the base of the firewall run up the firewall and then extend over to the d delis Pressure Regulator fuel rail s A return system wi
77. uel economy could drop severely as the high pressure causes too much fuel to be injected into the engine Fuel Lines Fuel lines are manufactured from steel rubber or plastic They can affect fuel delivery performance if they become clogged pinched kinked dented or ruptured Because fuel delivery systems keep fuel under pressure a ruptured fuel line will be evident by leaking fuel Likewise most other restrictions can identified with a simple visual inspection A restricted fuel supply line due to damage or blockage will have the same affect as a clogged inline filter If FST Pro test results indicate a restriction to the supply of fuel always make a visual inspection of the lines before performing additional diagnostics or replacing a suspect component A restricted fuel return line due to damage or blockage will have the same effect as an over restricting pressure regulator If FST Pro test results indicate a restriction to the return of fuel always make a visual inspection of the lines before performing addition al diagnostics or replacing a suspect component Form 824127 Setup and Installation Determining Where to Install the FST Inline Connection Regardless of the type of fuel delivery system the FST Pro is most effective at diagnosing malfunctions when connected inline with the flow of fuel The initial installation should be made at an access point along the fuel supply line as close as possible to the fuel rail Figs
78. ush the male endform into the female quick connect until it snaps securely into place Fig 7 Always test the connection by trying to pull it apart without pressing the release button Page Number 8 ONT aon Fig 1 Fig 2 Fig 7 Fig 5 Fig 6 Form 824127 To release the connection press and hold the release button on the side of the female quick connect while pulling the connection apart Fig 8 Do not attempt to release the quick connect connection using a disconnect tool as this may damage the fitting Replacement clips are included if needed Adapters The FST Pro includes a selection of adapters for connecting inline with the fuel delivery systems of a wide range of automotive makes and models The chart on pages 6 and outlines the adapters available and their applications Each adapter is etched with an identification number for easy reference Adapters can be purchased separately in sets according to the order number indicated in the chart In most cases selecting and installing adapters into the fuel delivery system and connecting the FST for testing is straightforward and logical Simply match the fuel system connection to the equivalent male and female adapter set and install them as outlined in the Setup and Installation instructions later in this manual Banjo Connections Banjo style connections are commonly used by many Asian and European manufacturers to connect a hose or fuel line to the fi
79. y regulated returnless system this is referred to as dead heading the fuel pump The flow will drop to zero and the pressure gauge will indicate the peak pressure output of the pump Peak pres sure will typically be 5096 to 100 higher than the normal operating specification This is termed the Peak Pressure Test and is effective only on return or electronically regulated returnless fuel systems Closing the valve on a mechanically regulated returnless system will have no effect on fuel pressure CAUTION A pump should never be dead headed for longer than a brief instant Doing so can cause serious damage to the fuel system and or pump Fig 19 Page Number 12 Form 824127 When the valve is rotated to the BYPASS position pointing up fuel is routed through the bypass port located on the side of the flowmeter just above the flow control valve Fig 20 Bypassing eliminates all restriction to the flow and the maximum volume output of the pump is indicated on the flowmeter Fuel pressure will drop to zero This is termed the Peak Flow Test and is applicable to return and returnless systems If the flow control valve in the CLOSED position is considered to simulate a closed throttle and the BYPASS position is considered to simulate wide open throttle WOT then any position in between would represent some unique throttle position between idle and WOT With this in mind the operator can simulate any engine demand scenario by
Download Pdf Manuals
Related Search
Related Contents
Fehlersuche - NC Engineering Electronic Services Disclosure - Pacific Community Credit Union User Handbook 酸素濃度 有毒ガス測定 MANUEL D`UTILISATION User`s Manual Jarden BAP1412-U air purifier tk1 KIT - Rack Attack Manual Técnico DC Inverter 1x1 - INCO. Instalaciones Comerciales Copyright © All rights reserved.