Home
Milwaukee MW14 User's Manual
Contents
1. WARRANT Milwaukee Milwaukee USER MANUAL This instrument is warranted from all defects in materials and manufacturing for a period of two years from the date of purchase If during this period the repair or replacement of parts is required where the damage is not due to negligence or erroneous operation by the user please return the parts to either dealer or our office and the repair will be effected free of charge Note We reserve the right to modify the design construction and appearance of our products without advance notice IRON HIGH RANGE SPECIFICATIONS MODEL MW14 MW 14 RANGE 0 00 to 5 00 ppm RESOLUTION 0 01 ppm ACCURACY 0 04 ppm 2 of reading 25 C TYPICAL EMC DEV 0 01 ppm LIGHT SOURCE Light Emitting Diode 525 nm LIGHT DETECTOR Silicon Photocell METHOD Adaptation of the EPA Phenantroline method 315B for natural and treated waters The reaction between iron and reagent causes an orange tint in the sample ENVIRONMENT 0 to 50 32 to 122 F max 95 RH non condensing BATTERY TYPE 1x 1 5V AAA Tron AUTO SHUT OFF After 3 minutes of non use and 2 minutes after reading MWeiq DIMENSIONS 81 5 x 61 x 37 5 mm 3 2 x 2 4 x 1 5 WEIGHT 64 g 2 25 oz OPTIONAL ACCESSORIES Reagent Sets 2720416 Iron powder reagent 25 pcs Other Accessories 3000100 Glass cuvettes with caps 2 pcs 3000200 Tissue fow wiping cuvettes 2 pcs 3000300 1 5V AAA batteries 4 pcs O80 LMNLSI PRELIMINARY EXAMINATION Please ex
2. amine this product carefully Make sure that the instrument is not damaged If any damage occured during shipment please notify your Dealer Each MW 14 meter is supplied complete with e Two Sample Cuvettes and Caps e Six powder reagents for Iron High Range e 1x 1 5V AAA Battery e Instruction Manual FUNCTIONAL DESCRIPTION 2 1 Dust cover m 2 Cuvette with cap 3 3 Cuvette holder A 4 Liquid Crystal Display 7 5 Button 8 OPERATION Add Press button After all the segments are dis played C 1 Add appears with Press blinking the meter is ready e Fill the cuvette with 10 mL of unre L I acted sample and replace the cap Place the cuvette into the meter and close the meters cap e Press the button When the display shows Add C 2 with Press blink ing the meter is zeroed aP l e Turn the meter on by pressing the Add Press e Remove the cuvette open it and add the content of one packet of 2720416 reagent Replace the cap and shake gently for 2 minutes until the powder is completely dissolved Replace the cuvette into the meter e Wait for 2 minutes and 30 seconds lt P and then press the button or press lt e gt and hold the button until the timer is displayed on the LCD Q e The instrument directly displays the concentration of iodine in ppm The meter automatically turns off after 2 minutes BATTERY REPLACEMENT To sav
3. e the battery the instrument shuts down after 3 minutes of non use and 2 minutes after reading One fresh battery lasts for a minimum of 5000 measurements depending on the light level When the battery capacity is under 10 bAt appears on the LCD at start up If the battery is empty and accurate measurements can t be taken any more the instrument shows bAd then bAt each for 1 second and turns off To restart the instrument the battery must be replaced with a fresh one To replace the instrument s battery follow the steps e Turn the instrument off by holding the button until the meter shuts off Turn the instrument upside down and remove the battery cover with a screwdriver Remove the battery from its location and replace it with a fresh one Insert the battery cover and replace the screw with a screwdriver
Download Pdf Manuals
Related Search
Related Contents
Milwaukee 6236N Saw User Manual USER MANUAL HP H2L87AA User's Manual Update-Handbuch vwd portfolio manager 3.01 IRD・IDDシリーズ取扱説明書(補足分) Copyright © All rights reserved.
Failed to retrieve file