Home

METRObility Optical Systems Metrobility R104-11 User's Manual

image

Contents

1. SW1 SW2 HDFL OPEN AN4 OPEN FD OPEN 100M4 OPEN ANI OPEN AN3 OPEN 100M1 OPEN 100M3 OPEN AN2 OPEN 100M2 OPEN DIP switches 000000 Port 1 Port 2 Port 3 Port 4 titt 4 ia G Power Connector Metrobility 4 port Switch 5 When setting DIP switches on SW2 the OPEN position is when the lever of the switch is pushed up toward the word OPEN The CLOSED position is when the lever is pushed down toward the board On the rocker DIP switch SW 1 the OPEN position is when the OPEN side of the switch is down and the numbered side is up The CLOSED position is when the numbered side of the switch is down and the OPEN side is up See illustration below CLOSED Auto Negotiation Switch AN1 AN2 AN3 AN4 Switch ANx controls the use of auto negotiation on its associated port e g ANI sets auto negotiation on Port 1 To enable auto negotiation the switch must be OPEN To disable this function the switch must be CLOSED By default auto negotiation is enabled When auto negotiation is enabled on a port it advertises 10 100Mbps half full duplex capabilities When auto negotiation is disabled the port s duplex is determined by the FD switch setting and its speed is set by its corresponding 100Mx switch Speed Switch 100M1 100M2 100M3 100M4 The 100Mx speed switch
2. to repair or to replace at Telco s plant at Massachusetts any part found to be defective under normal use and service within the warranty period specified herein provided a Telco is promptly notified in writing upon discovery of such defects b The defective parts are returned to Telco transportation charges prepaid in accordance with Telco s instructions c Telco s examination shall disclose to its satisfaction that such defects have not been caused by misuse abuse neglect accident or adjustments other than those specified in the Telco Operating and Maintenance Manual Telco shall have no responsibility under this warranty for defects which have been caused by misuse abuse improper application repair alteration accident or negli gence in use storage transportation or handling Further the original identifi cation markings must not have been removed defaced or altered d Equipment has been installed and operated and maintained in complete accordance with the Telco Operating and Maintenance Manual and good engineering practice Though component parts of Telco manufactured goods are covered by the above warranty TELCO MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE NOR ANY OTHER WARRANTY EXPRESS OR IMPLIED FOR ANY EQUIPMENT OR MERCHANDISE NOT MANUFACTURED BY TELCO FOR EXAMPLE BUT WITHOUT LIMITATION ACCESSORIES AND AUXILIARY ITEMS However Telco will cooperate reasonably with Purchaser
3. Telco Systems A BATM Company METROBILITY FOUR PORT SWITCH 10 100 BASE aa GS EG pwr Installation amp User Guide Model R104 11 Metrobility Four port Switch R104 11 10 100Mbps Four Port TX Switch This publication is protected by the copyright laws of the United States and other countries with all rights reserved No part of this publication may be reproduced stored in a retrieval system translated transcribed or transmitted in any form or by any means manual electric electronic electromagnetic mechanical chemical optical or otherwise without prior explicit written permission of Telco Systems O 2006 Telco Systems Inc All rights reserved Printed in USA Metrobility 4 port Switch Installation amp User Guide DICO iii 4 InstallabonGuide ladina 5 STEP Unpack the Line Card u y t niia 3 STEP 2 ANE n WIO ES er ee ee ene ee ee See eee 5 STEP S Install qhe Cardia easier 9 STEP 4 Connect to the Network J LLULLU aus akasqassssapss 10 User Gode Liceali 11 LED ver REE EE 11 Foll Duplex Flow Control EDEL ir 11 Techimical Spello 12 Product Safety EMC and Compliance Statements 13 PTE eee Jen 14 Metrobility Metrobility Optical Systems and NetBeacon are registered trademarks the Metrobility Optical Systems logo and WebBeacon are trademarks of Telco Systems a BATM company All others are trademarks of their respective owners The inform
4. 0Mbps speed control Backpressure flow control in half duplex mode Pause frame flow control in full duplex mode configurable through software only Built in crossover functionality that eliminates the need for crossover cables IM bit buffer of built in memory Full compliance with applicable sections of IEEE 802 3 IEEE 802 3u and IEEE 802 x standards A non blocking high performance switching engine with the ability to learn up to 1 024 MAC addresses Support for long packets up to 1518 bytes for un tagged frames or up to 1522 bytes for IEEE 802 3ac tagged frames 4 Overview Follow the simple steps outlined in this section to install and start using the R104 NOTE Electrostatic discharge precautions should be taken when handling any circuit board Proper grounding is recommended i e wear a wrist strap Unpack the Line Card Your order has been provided with the safest possible packaging but shipping damage does occasionally occur Inspect your card carefully If you discover any shipping damage notify your carrier and follow their instructions for damage and claims Save the original shipping carton if return or storage of the unit is necessary Set the Switches Two sets of DIP switches located on the back of the circuit board allow you to select from several modes of operation These switches are clearly marked on the printed circuit board Default Switch Settings
5. abled CLOSED A blank space indicates that the switch setting is not applicable and can be either OPEN or CLOSED Installation Guide Install the Card The R104offers the ease of plug and play installation and is hot swappable The unit must be firmly secured to the chassis before network connections are made Follow the simple steps outlined below to install the card e Grasp the card by the front panel as shown Card Guide Slot for Manageme ard Q IMPORTANT Thumb Screw Tighten thumb screw Card Guide to secure each card firmly to chassis before making Blank Panel network connections e Insert the card into either slot in the R400 or R1000 In the R5000 chassis any slot excluding slot 17 Make sure the top and bottom edges of the board are aligned with the top and bottom card guides in the chassis Do not force the card into the chassis unnecessarily It should slide in easily and evenly Slide the board in until the top and bottom edges of the front panel are flush and even with the top and bottom edges of the chassis To secure the card to the chassis turn the thumbscrew clockwise until it is snug The unit is now properly installed and ready for connection to the network Metrobility 4 port Switch 9 10 Connect to the Network To connect the R104 to the network insert the t
6. ation contained in this document is assumed to be correct and current The manufacturer is not responsible for errors or omissions and reserves the right to change specifications at any time without notice The Metrobility R104 11 is a four port 10 100Mbps TX switch that provides a cost effective solution for situations in which a simple switching option with few ports is required When configured for stacking in a Metrobility chassis the card eliminates the need for any external equipment This means the network administrator has one less piece of networking hardware to manage and monitor The R104 is designed to support a stack of up to four R5000 chassis thus enabling communication between the management card in each chassis The stacking line card enables up to 126 local ports and up to 126 remote ports using the access line cards to be managed under a single IP address This ability provides visibility and remote software control over the entire stack along with notification of a problem or failure to the network administrator Each 10 100Mbps Ethernet port supports auto negotiation of both duplex and speed as well as half and full duplex flow control Additionally each port includes automatic cross over functionality which eliminates the need for cross over cables for easier network setup The R104 offers the following key features e Auto negotiation to determine the best duplex and speed for data communications 10 10
7. control backpressure When half duplex flow control is activated the Radiance card generates a jamming pattern to force a collision on a port if a buffer cannot be allocated for the port s incoming packets Half duplex flow control is enabled by default OPEN The HDFL switch must be CLOSED to disable half duplex flow control on all four ports The switch must be OPEN to enable HDFL on all ports Metrobility 4 port Switch 7 The table below displays sample port configurations and the DIP switch settings used to obtain them The configuration column gives the auto negotiation speed and duplex options for each port By default all four ports are set to auto negotiate Tre menn ves Configuration Port 4 Port 1 AN AN AN AN AN AN AN AN 100 Half 10 Half 10 Half 100 Half AN AN 100 Half 10 Half 10 Half 100 Half 10 Half 100 Half 100 Half AN AN 100 Full 100 Half 10 Half 100 Half 100 Half 10 Half 100 Half 10 Half 10 Half 10 Half 100 Full 10 Full 100 Full 100 Half 100 Half 100 Half 10 Half 10 Half 100 Half 10 Half 100 Half 10 Half pon 2 pona porta ro a roomt an 10 ana 100 ane som GJ ee 1 AN indicates that auto negotiation is enabled indicates the switch is enabled OPEN indicates the switch is dis
8. controls the speed setting on its associated port e g 100M2 determines the speed on Port 2 If auto negotiation is disabled on a Port x its speed will be set to one of the following e 100Mbps if the 100Mx switch is OPEN default 10Mbps if the 100Mx switch is CLOSED When auto negotiation is enabled the 100Mx switch is ignored DIP switches also can be managed via console commands or with the Metrobility NetBeacon or WebBeacon management software Refer to the Command Line Interface Reference Guide NetBeacon Element Management Software Installation amp User s Guide or WebBeacon Management Software Installation amp Users Guide tor software management information 6 Installation Guide Duplex Switch FD Switch FD determines the duplex mode on all ports that have auto negotiation disabled The ports will operate at full duplex if FD is OPEN default They will operate at half duplex if FD is CLOSED If auto negotiation is enabled on a port that port will ignore the FD switch setting For example if FD is enabled and auto negotiation is disabled on Ports 1 and 2 and enabled on Ports 3 and 4 then Ports 1 and 2 will operate at full duplex while Ports 3 and 4 will ignore the FD switch setting The duplex mode for Ports 3 and 4 will be determined through the auto negotiation process Half Duplex Flow Control Switch HDFL For ports operating at half duplex the R104 provides an option to enable half duplex flow
9. el Input 200mV minimum 100Mbps 585mV 10Mbps Supported Link Length 100m Cable Type 10Mbps segments Category 3 4 or 5 UTP STP 100Mbps segments Category 5 or 5E UTP STP Data Rate Fast Ethernet 100Mbps half duplex 200Mbps full duplex Ethernet 10Mbps half duplex 20Mbps full duplex Power 5V 1A 5W Environmental Operating Temperature 0 to 50 C Operating Humidity 5 to 95 non condensing Weight 3 5 oz 0 1 kg 12 User Guide Product Safety EMC and Compliance Statements This equipment complies with the following requirements e CSA CE CB FCC Part 15 Class A EN55022 Class A emissions EN55024 1998 immunity ICES 003 Class A emissions This product shall be handled stored and disposed of in accordance with all governing and applicable safety and environmental regulatory agency require ments The following FCC and Industry Canada compliance information is applicable to North American customers only USA FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equip ment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instruction manual
10. f any merchandise manufactured by Telco shall in no case exceed the price allocable to the merchandise or part thereof which gave rise to the claim Purchaser will hold Telco harmless with respect to any claims or actions by third parties In particular Telco expressly disclaims and shall in no event be liable for any indirect special incidental or consequential damages Metrobility 4 port Switch 15 A BATM Casa kuy US Headquarters 2 Hampshire Street Suite 3A Foxboro MA USA 02035 tel 1 781 551 0300 fax 1 781 255 2344 www telco com 5660 000023 D 12 06
11. in attempting to secure where possible the benefit of any warranties which the manufacturer of such non Telco items may provide All ordered replacement parts or parts replaced during the warranty period assume the unexpired portion of the original parts warranty or ninety 90 days from date of shipment whichever is longer 14 User Guide Replacement Repair or Refund Procedure for Hardware Telco s sole obligation under this express warranty shall be at Telco s option and expense to repair the defective product or part or deliver to Customer an equivalent product or part to replace the defective item All products that are replaced will become the property of Telco Systems Replacement products or parts may be new or reconditioned Telco warrants any replaced or repaired product or part for ninety 90 days from shipment or the remainder of the initial warranty period whichever is longer Telco reserves the right to refund the purchase price paid for the defective product as its exclusive warranty remedy To Receive a Return Materials Authorization RMA Number Please contact the party from whom you purchased the product If you purchased the product directly from Telco Systems contact the Telco Systems Customer Care Group Software Telco warrants to Customer that each software program licensed from it will if operated as directed in the user documentation substantially achieve the functionality described in the user documentatio
12. may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Canadian Radio Frequency Interference Statement This Class A digital apparatus meets all requirements of the Canadian Interfer ence Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Metrobility 4 port Switch 13 Warranty and Servicing Telco Systems Product Warranty TELCO MAKES NO WARRANTIES EXCEPT AS HEREIN SET FORTH Telco warrants that the equipment and accessories manufactured by Telco when used in the application and manner for which they are intended will be free from defects caused by faulty material or poor workmanship from the date of shipment This warranty is subject to change at any time The warranty that applies is that which is in effect at the time the equipment ships Warranty period is specific to particular product offerings These periods are as follows Metrobility Products 1 year IP and EdgeGate Products 1 year Telco s liability under this warranty is limited to the obligation at Telco s sole option
13. n for a period of ninety 90 days from the date of purchase from Telco or its authorized reseller No updates or upgrades are provided under this warranty Telco s sole obligation under this express warranty shall be at Telco s option and expense to refund the purchase price for the software product or replace the software product with software which meets the requirements of this warranty as described above Customer assumes responsibility for the selection of the appropriate programs and associated reference materials Telco expressly disclaims any warranty or representation that its software products will meet Customer s requirements or work in combination with any hardware or software products provided by third parties that the operation of the software products will be uninterrupted or error free or that all defects in the software products will be corrected The foregoing warranties are in lieu of any and all other warranties expressed or implied including but not limited to warranties of merchantability fitness for a particular purpose or against infringement of any rights of third parties Telco s liability on any claim for money damages including without limitation negligence for any loss or damage arising out of connected with or resulting from the sale of products hereunder or from the performance or breach thereof or from the design manufacture sale delivery resale installation inspection repair operation or use o
14. r steady dna has a valid link and is running at OFF No link detected The port is sending or receiving data in full green blinking duplex mode activity AT duplex amber blinking The port is sending or receiving data in half duplex mode OFF The port has no data activity Full Duplex Flow Control FDFL Full duplex flow control is provided as a means of avoiding packet loss during times of network congestion With FDFL enabled default the R104 issues a PAUSE frame when there is no buffer space available for incoming packets FDFL is configurable through management software only When FDFL is enabled it is set on all four ports However FDFL is applicable only to a port when the following conditions are met The chassis stacking line card is in full duplex mode Auto negotiation is enabled on the port During auto negotiation the port s link partner indicated that it supports PAUSE frames Refer to the Command Line Interface Reference Guide NetBeacon Element Management Software Installation amp User s Guide or WebBeacon Management Software Installation amp User s Guide for software management information Metrobility 4 port Switch 11 Technical Specifications Network Connections Twisted Pair Interface Connector Shielded RJ 45 8 pin jack Impedance 100 Ohms nominal Signal Level Output differential 0 95 to 1 05V 100Mbps 2 2 to 2 8V 10Mbps Signal Lev
15. wisted pair cables into the appropriate connectors Be sure the card is secured to the chassis by tightening the thumbscrew before making network connections The R104 provides four shielded RJ 45 connectors that support a maximum segment length of 100 meters Use Category 3 4 or 5 cables for 10Mbps segments use only Category 5 or SE cables for 100Mbps segments Insert your connectors as shown below Once power is applied to the card correct connectivity can be verified via the link LK LED if an active device is connected to the remote end of the cable 25D B 2 sui Bi Installation Guide This section contains information regarding the operating features of the Metrobility R104 LED Indicators The R104 provides several LEDs for the visible verification of unit status and proper functionality These LEDs can assist in troubleshooting and with overall network diagnosis and management There are separate link speed and activity duplex indicators for each port After power is applied to the card verify correct connectivity via the LK LEDs LED LED Label Name Color Status Indication PWR power green steady The unit is ON green steady The port has a valid link and is running at 100Mbps link i F LK speed ambe