Home

Maytag PGC2TC Technical Literature

image

Contents

1. TECHNICAL SPECIFICATIONS Model PGC2T C and L Series v ISEER SmartStart M1200 Product Line Two Stage Fixed Speed ECM High Efficiency Upflow Horizontal and Downflow Gas Furnaces 95 1 AFUE Input 60 000 120 000 Btuh The high efficiency gas furnace may be installed free standing in a utility room basement or enclosed in an alcove or closet The rounded corner jacket provides a pleasing appliance appearance Design certified by CSA for application in Canada and the United States Features and Benefits i SEER Energy efficient brushless DC ECM motor gives up to 1 SEER point efficiency gain in cooling 100 fired and tested All units and each component are tested on the manufacturing line Best packaging in the industry Unique corner post design assures product will arrive to the homeowner dent free 30 second blower delay at start up assures a warm duct temperature at furnace start up Adjustable blower off settings 60 90 120 and 180 seconds 30 second post purge increases life of heat exchanger Hot surface igniter Innovative application of an appliance type igniter with a 20 year history of reliability Utilizes proven SmartStart technology Color coded wire harness Designed to fit the components all with quick connect fittings for ease of service and replacement Flexible category IV venting system May be vertically or horizontally vented using either a one pipe or two p
2. 7 8 A Electric i LA 25 3 8 A 118 Vent pipe o Suns Gas 93 W F 2212 PN i 1 5 8 Vent pipe Gas 1 5 8 03 hia a 4 Knockouts both sides Cond 1 1 16 28 gt Condensate 23 gt LEFT SIDE VETUS FRONT VIEW RIGHT SIDE TL 95 196 Downflow Furnace TOP VIEW BOTTOM VIEW C gt Cabinet J Tas Size Sr ae Front Brace 1712 1578 1938 2412 227 8 Dimensions shown in inches 7 8 Electric OQ 7 8 Gas OQ 1 5 8 22 1 4 Electric 7 8 Gas 1 5 8 Vent pipe ow 22 1 2 25 3 8 gt o 2 a 3 17 1 4 Cond 1 1 16 Cond 1 1 16 17 7 16 LEFT SIDE FRONT VIEW RIGHT SIDE BLOWER PERFORMANCE PGC2TC TL PGC2TC TL 95 1 AFUE Two Stage Gas Furnace Model Number Motor Switch Settings External Static Pressure in W C G 0 OFF 1 ON 0 3 0 4 0 5 Heating Input Btuh 3 7 4 8 cOlcocjojojoj o o o TC TL 060D 24B 60 000 TC TL 80D 35C 80 000 1 Motor Switch Settings are for heating speeds using HEAT switches 1 2
3. 3 amp 4 and cooling speeds using COOL switches 5 6 7 amp 8 2 Two openings are recommended for airflows above 1 600 CFM if the filter s is are adjacent to the furnace 3 Data is shown without filter 4 Temperature rises in the table are approximate Actual temperature rises may vary 5 Cells shaded in gray indicate a temperature rise outside of the recommended range 6 When in low stage the circulating airflow is 70 of the tables high value 2 stage furnaces only BLOWER PERFORMANCE PGC2TC TL CONTINUED PGC2TC TL 95 1 AFUE Two Stage Gas Furnace Model Number Motor Switch Settings External Static Pressure NWE amp 0 OFF 1 ON f 0 3 Heating Input 0 4 0 5 0 6 Btuh 3 7 TC TL 100D 35C 100 000 TC TL 120D 45D 120 000 1 Motor Switch Settings are for heating speeds using HEAT switches 1 2 3 amp 4 and cooling speeds using COOL switches 5 6 7 amp 8 2 Two openings are recommended for airflows above 1 600 CFM if the filter s is are adjacent to the furnace 3 Data is shown without filter 4 Temperature rises in the table are approximate Actual temperature rises may vary 5 Cells shaded in gray indicate a temperature rise outside of the recommended range 6 When in low stage the circulating airflow
4. demark Trademark of Maytag Corporation or its related companies 2014 All rights reserved 823C 0514 Replaces 823C 0913 Printed in U S A 05 14 B e Q HRAI v MEMBER COMPANY Doe 10 pared e
5. ipe system for maximum flexibility in installation High Static Blowers All models equipped with high static blowers Low Boy Height Easy to apply in low ceiling applications works well with taller high SEER coils easier to handle and install Tubular primary heat exchanger Heavy gauge aluminized steel heatexchanger and stainless steel secondary heatexchanger assures a long life 90 second fixed cooling cycle blower off delay TDR increases cooling performance when matched with a NORDYNE coil Variable Speed Blower Kit Upgradable to full variable speed with kit LP convertible Simple burner orifice and regulator spring change for ease of convertibility Diagnostic lights for easy troubleshooting without counting flashes Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes Incorporates integrated control board with connections for electronic air cleaner and humidifier Two piece door design enhances furnace appearance and uses captured screws to prevent losing door screws Blower Compartment Sealed door to reduce air leakage and insulated for ultra quiet operation Sealed Vestibule reduces burner and inducer sound levels 2 Stage Inducer Optimizes efficiency on first stage heat and reduces sound levels GAS FURNACE COMPONENTS LOCATION OF FURNACE COMPONENTS Finish Flange Flame Roll Out Bu
6. is 7096 of the tables high value 2 stage furnaces only IDENTIFICATION CODE PGC 2 T C 090 C 23 M Maytag Gas Cabinet Width Compact I B 17 50 C 21 00 Design Series D 24 50 S Single Stage Cooling Airflow T Two Stage 23 2 3 Tons 24 2 4 Tons f 35 3 5 Tons A 80 Upflow Horizontal 45 4 5 Tons C 92 1 95 1 Upflow Horizontal L___C Standard V VSB K 80 Downflow D 90 AFUE Low NOx L 92 1 95 1 Downflow Input Heating Capacity 060 60 000 100 100 000 080 80 000 120 120 000 SPECIFICATIONS PGC2TC PGC2TL MODEL NUMBERS 060D24B 080D35C 100D35C 120D45D Input Btuh a 60 000 39 000 80 000 52 000 100 000 65 000 120 000 78 000 Heating Capacity Btuh 57 000 37 050 76 000 49 400 95 000 61 750 114 000 74 100 AFUE 95 1 95 1 95 1 11x10 11x10 11x10 3 4 BLDC _ 3 4 BLDC 1 BLDC 35 65 35 65 40 70 135lbs 145lbs 160lbs TL 120 is 94 8 AFUE Note All models are 115V 60 Hz Gas Connections are 1 2 N P T AFUE Annual Fuel Utilization Efficiency a Ratings to 2 000 ft Over 2 000 ft reduce 4 for each 1 000 ft above sea level ACCESSORIES PGC2T C L KITS fixed specd io variable speed Y Side wall vent i Bottom return filter 20 per box C cabinet Bottom return filter 20 per box D cabinet VENTING All models are approved for vertical non direct 1 pipe and direct 2 pipe venting applications See Ven
7. rner Sensor Switch Assembly Pressure Switches Se een Igniter Inducer S a Gas Valve Main Air Limit Switch Furnace Control Board Inducer Limit Switch Inducer Assembly ate 9 ATT vd Pressure Switches ARALI ApS Condensate Blower Door Switch Transformer Motor Control Box Motor Choke b C amp D cabinets only i Motor Control Board Blower Assembly Upflow Horizontal Gas Furnace Components E Blower Assembly Finish Flange behind blower panel Motor Choke i C amp D cabinets only 3 AEN i 77 Motor Control Board Furnace Control Board Blower Door Switch gt behind blower panel Transformer 4 Pressure Switches Vent Limit Switch Inducer Assembly 8i Main Air Limit Switch Igniter He Flame Sensor MN a Roll Out S Assembly Switch Manifold Gas Valve Downflow Gas Furnace Components DIMENSIONS TC 95 1 Upflow Horizontal Furnace TOP VIEW BOTTOM VIEW Cabinet Ro Size nn 1 Front Brace i712 157 8 C Cabinet 21 19 3 8 D Cabinet 24 1 2 22 7 8 Dimensions shown in inches 1 31 4 Ll Combustion Air T stat 22 4 2 A 7 8 Electric
8. t Table below for specified sizes and allowable lengths DIRECT VENT FURNACE SINGLE PIRE LENGIH FT DUAL PIPE LENGTH ft WITH FURNACE with 1 long radius elbow MODELS INSTALLATION 1 long radius elbow on each pipe BTU OUTLET OUTLET INLET OUTLET INLET OUTLET 3 Diameter Upflow 60 000 Horizontal Downflow gx 90 rc i Upflow Horizontal Downflow _ Upflow 100 000 Horizontal ee SS Hc Upflow wv S o S w G o 120 000 Horizontal NANA Downflow _ Na o wNA 90 X 3 NOTES 1 Subtract 2 5 ft for each additional 2 inch long radius elbow 5 ft for each additional 2 inch short radius elbow 3 5 ft for each additional 3 inch long radius elbow and 7 ft for each additional 3 inch short radius elbow Subtract 5ft for each 2 tee and 8ft for each 3 tee 2 Two 45 degree elbows are equivalent to one 90 degree elbow 3 This table applies for elevations from sea level to 2 000 ft For higher elevations decrease pipe lengths by 8 per 1 000 ft of altitude We Encourage Professionalism ENERGY STAR k Thi h Technici PARTNER Certification by NATE E MAYTAG Before purchasing this appliance read important energy cost and efficiency information available from your retailer Specifications and illustrations subject to change without notice and without incurring obligations Manufactured under license by NORDYNE O Fallon MO Registered Tra