Home
Maytag MEDC215EW Dimension Guide
Contents
1. Electric Dryer PRODUCT MODEL NUMBERS MEDC300B MEDC400B MEDX500B MEDC555D MEDX655D MEDC 215E MEDC415E Dryer Dimensions 29 m 99 433 3 Ii 433 8 1102 mm 1102 mm 1 2 r 13 mm 11 2 38 mm NOTE Leveling legs should be 1 2 13 mm to match height of 3 6 cu ft capacity washer or 1 38 mm to match height of 3 8 cu ft capacity washer Minimum spacing for recessed area or closet installation The dimensions shown following are for the minimum spacing allowed m Additional spacing should be considered for ease of installation and servicing m Additional clearances might be required for wall door and floor moldings m Additional spacing of 1 25 mm on all sides of the dryer is recommended to reduce noise transfer m For closet installation with a door minimum ventilation openings in the top and bottom of the door are required Louvered doors with equivalent ventilation openings are acceptable E Companion appliance spacing should also be considered Wide opening side swing door Wide opening hamper door 133 4 349 mm 223 4 578 mm 273 4 705 mm Most installations require a minimum 512 140 mm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Minimum Required Spacing 114 max 18 457 mm Taaa HK 2 a Sle are gt i 5mm 737mm 25mm 5mm 705mm 140 mm A B C A Recessed area
2. B Side view closet or confined area C Closet door with vents Additional spacing recommended W10562358A 02 2015 ELECTRICAL REQUIREMENTS To supply the required 3 or 4 wire single phase 120 240 volt 60 Hz AC only electrical supply or 3 or 4 wire 120 208 volt electrical supply if specified on the serial rating plate on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit VENTING REQUIREMENTS Exhaust venting Exhaust your dryer to the outside 4 102 mm The Vent System Chart provides venting requirements that will diameter vent is required Rigid or flexible metal exhaust vent help achieve best drying performance must be used Do not use plastic or metal foil vet Exhaust hood must be at least 12 805 mm from the ground or any object that may be in the path of the exhaust Vent System Chart Exhaust hoods Number of Type Box louvered Recommended Styles 90 turns of vent hoods or elbows Louvered Hood Box Hood re Rigid metal 44 ft 13 4 m 38 ft 11 6 m Acceptable Style 8 Rigid metal 35 ft 10 7 m 29 ft 8 8 m oa Rigid metal 27 ft 8 2 m 21 ft 6 4 m Vent System Chart Di oee Number of Type Box louvered or 90 turns of vent Angled hoods or elbows Long Vent Models Only Determine vent path Rigid metal 120 ft 36 6 m E Select route that will provide straightest and most direct path
3. outdoors Rigid metal 110 ft 33 5 m Rigid metal 100 ft 30 5 m m Plan installation to use fewest number of elbows and turns m When using elbows or making turns allow as much room as possible m Bend vent gradually to avoid kinking m Use as few 90 turns as possible Rigid metal 80 ft 24 4 m Rigid metal 70 ft 21 3 m Determine vent length and elbows needed for best drying performance g Rigid metal 90 ft 27 4 m m Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in Vent System Chart Exhaust systems longer than those specified will m Shorten life of dryer m Reduce performance resulting in longer drying times and increased energy usage Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only For complete details see Installation our products we reserve the right to change materials and specifications without notice Instructions packed with product Specifications subject to change without notice
Download Pdf Manuals
Related Search
Related Contents
STG SOL Emulsion Z+ LV - TDKラムダ Open and save Desenvolvimento de um sistema de pré Fujitsu PRIMERGY RX2540 M1 Nobo 1902551 projection screen Black & Decker IR05X Use & Care Manual accOmpagnement à la scolarité manual de instalación Copyright © All rights reserved.
Failed to retrieve file