Home
Master Bilt MCR-33-101 User's Manual
Contents
1. one 6F43 EPH NSF ANSI 7 MCR 33 101 R MASTER BILT Refrigeration Solutions ITEM NO PROJECT LOCATION DATE Full length evaporator coil and vertical fan tower provide evenly distributed cooling QTY u MASTER CHILL MGR 33 101 amp MCR 33 102 SERIES Roll in amp Pass Thru Blast Chillers ROLL IN MODELS LI MCR 33 101 LI MCR 33 102 PASS THRU MODELS LI MCR 33 101PT LI MCR 33 102PT FEATURES CONSTRUCTION e Stainless steel interior and exterior with polyurethane foamed in place insulation e Interior light e Door gasket heater e High velocity forced air convection through evaporator coil e HACCP compliant recording ther mometer for blast chiller ambient air temperature requires printer to have record e 4 food temperature probes with se quential readout display in MCR 33 101 8 probes in MCR 33 102 e Automatic chill cycle control with food temperature probes DOORS e Door dimensions 30 x 78 e Flush mounted e 36 high 16 ga stainless steel kick plate on door exterior REFRIGERATION SYSTEM e An air or water cooled condensing unit will be supplied depending on application MQ MASTER BILT Refrigeration Solutions 908 Highway 15 North New Albany MS 38652 PHONE 800 647 1284 or 662 534 9061 FAX 800 232 3966 or 662 534 6049 www master bilt com CONTROL PANEL e HACCP compliant recording features e Surface mounted on exterior of blast
2. chiller e On off switch e Digital readout of interior ambient temperature e Digital cycle timer e Microprocessor control system enclosed in easily accessible box e Automatic air defrost cycle e Automatic hold cycle e Audible alarm at end of chilling cycle RACK e Racks provided MCR 33 10 Mie sssadercsncssornernimaresssss 1 MCR 33 102 isisusanscnnnecscrsvoedaesses 2 e Stainless steel construction e Accomodates 26 pans 12 x 20 x 21 2 two per each of 13 ledges e Ledges on 4 2 spacing e Fach pan holds up to 10 pounds of food for total rack quantity of 260 Ibs e Rack dimensions 24 2 wide x 27 deep x 68 i6 high e Rack mounted on heavy duty swivel casters COOLING TIME e Maximum load of 260 pounds of food requires approximately 90 min utes per cooling cycle depending on food density and input temperature of food WARRANTY e Standard limited one year extended compressor optional four year ex tended warranty available one year limited parts limited 10 year panel 0 a BLO Q Optional finishes QO Add suffix C for correctional model Printer package Extended four year compressor warranty MASTER CHILL MCGR 33 101 amp MCR 33 102 SERIES ROLL IN amp PASS THRU BLAST CHILLERS BLAST CHILLER TECHNICAL SPECIFICATIONS DIMENSIONS DIMENSIONS in inches in millimeters MAX MODEL L D H L D H VOLTS MCA FUSE SHIP WT LB KG ROLL IN ROLLIN Mcressao 7o
3. 1287 2 08 web Master Bilt Products division of Standex International Inc All rights reserved Printed in U S A
4. 7 s60 255 50 70 30 3 150_ BCLZ0750C 7 2 37 322 7 8 1 D 534 E BCLZO750E 7 2 37 322 7 8 s D 534 730 332 32 40 161 83 MCR 33 102 500 LB CAPACITY LESS THAN 1 HOUR PULL DOWN TIME BCLZ1500C_ 15 70 782 7 8 15s F 116 1 990 450 90 125 52 6 278 MCR 33 102 500 LB CAPACITY LESS THAN 1 HOUR PULL DOWN TIME WATER COOLED CONDENSING UNITS SCLZ100WC 10 54 800 7 8 1 s E 1053 910 414 66 100 42 215 SCLZ100WE 54 800 VOLTAGE KEY B suffix 208 230 or 230 volt 60 cycle one phase C suffix 200 230 or 208 230 volt 60 cycle three phase E suffix 460 volt 60 cycle three phase Based on 90 F ambient Electrical ratings for condensing unit only See National Electrical Code if units are combined on a single circuit 1 Locking Latch This Side For Padlock Padlock By Others go BASE C 46 1 2 Air Flow can Tan qt Air Flow Air Flow lt lt lt lt a To a a Piping l 10 172 T Hh Connections 7 1 2 N lature And 1 2 Di 29 7 16 Saral Number Plates Whiting Holes 5 8 Dia Mounting Holes 42 1 2 Electrical Connections Inside Weather Hood 5 8 Dia Mounting Holes 1 Locking Latch This Side For Padlock Padlock By Others 46 1 2 BASE D a 28 1 4 se Air Flow 42 7 8 Piping Connections 10 1 2 7 Nomenclature And Serial 7 112 i 35 1 2 Number
5. A refrigerant SUCTION O sien DRAWING TEMP LIQUID SUCTION PP 4 5 RECEIVER SHIP PUMPDOWN WI CAP 90 LB KG MCA MOP RLA LRA MCR 33 101 200 LB CAPACITY 2 HOUR PULL DOWN TIME 3 3 3 7 8 M2 114 330 150 24 35 147 86 BTUH UNIT CONNECTION DIMENSIONS 10 F SIZES SEE azz OSIRIS ww R NINIAN DOA e ele Rie p S a re ee Olea O 7 8 3 MCR 33 101 200 LB CAPACITY 1 5 HOUR PULL DOWN TIME MSLZ0151C 4 14 994 1 2 7 8 M2 114 230 105 32 40 15 99 BSLZ0400B 4 15 047 1 2 7 8 C 41 5 510 232 42 60 26 8 129 BSO C EREE AEO aa eS eee ees MCR 33 101 250 LB CAPACITY 2 HOUR PULL DOWN TIME IMSLZ0151C 4 14994 1 2 7 8 M2 114 230 105 32 40 15 99 BSLZ0400B 4 15 047 1 2 7 8 C 41 5 510 232 42 60 26 8 129 BSLZ0400C_ 4 15 047 1 2 78 C as 510 232 32 40 15 9 MCR 33 101 250 LB CAPACITY 1 3 HOUR PULL DOWN TIME BSLZO600C_ 6 21 651 1 2 78 C 41 5 550 250 41 60 23 9 156 BCLZ0400C 4 21 531 5 8 Us C 415 530 230 44 60 26 3 161 BCLZ0400E 4 21 531 5 8 Ws C 41 5 530 230 22 30 10 2 60 ESAT RSS Sess E E Ee S MCR 33 101 250 LB CAPACITY LESS THAN 1 HOUR PULL DOWN TIME Be ACC FESO S ES ES SS PUB SSO rs aa 72 37 322 7 8 s D 534 730 332 32 40 161 83 MCR 33 101 250 LB CAPACITY LES
6. Plates MA e Dia 5 8 Dia Mounting Holes ee l 42 1 2 Electrical Connections Inside Weather Hood 5 8 Dia Mounting Holes 1 Locking Latch This Side For Padlock Lock Provided By Others 41 7 8 BASE E 23 Air Flow 5 8 Dia Mounting Holes Nomenclature amp Serial Number Plates Located On Outside Of Electrical Box Cover Electrical Connections Inside Weather Hood LG 0 Piping i Connections 4 1 1 2 Dia Lifting Holes 38 3 4 5 8 Dia Mounting Holes 42 3 4 MASTER CHILL MGR 33 101 amp MCR 33 102 SERIES ROLL IN amp PASS THRU BLAST CHILLERS REFRIGERATION SYSTEM TECHNICAL SPECIFICATIONS cont 1 Locking Latch This Side For Padlock BASE F Lock Provided By Others 74 1 4 ee 22 7 8 PA ies Air Flow p_o _____________ b a ana eS A iping Connections l 4 1 4 2 Dia Electrical L_ 32 3 4 1 99 3 4 Uhtng Holes Connections 5 8 Dia Mounting Holes 38 3 4 Inside Dia Mounting Hol Weather Hood 75 1 4 vee eer ae Nomenclature amp Serial Number Plates Located On Outside of Electrical Box Cover BASE M2 a 36 1716 _____ a PIPING CONNECTONS 37 1 4 38 BASE M3 n ame Ei 17 7 8 4 3 4 DIA LIFTING HOLES 24 ELECTRICAL z 3 8 DIA MOUNTING ac CONNECTIONS 26 1 8 INSIDE WEATHER HOOD 25 7 8 4 3 4 DIA LIFTING HOLES PIPING 28 NNECTON a
7. S THAN 1 HOUR PULL DOWN TIME WATER COOLED CONDENSING UNITS 72 39 600 5 8 s D 784 730 332 5o 80 315 161 SCLZO75WE 7 2 39 600 5 8 1 D 784 750 341 32 40 16 1 83 MCR 33 102 400 LB CAPACITY 2 HOUR PULL DOWN TIME IMSLZ0221C_ 6 23 018 1 2 1 e MS a MDLZ0231C 4 22 958 1 2 T s M3 152 530 241 42 60 263 161 MCR 33 102 400 LB CAPACITY 1 5 HOUR PULL DOWN TIME E 6 29 187 5 8 We MS T 70_ d s 28 2 161 MCR 33 102 500 LB CAPACITY 2 HOUR PULL DOWN TIME IMDLZ0291C 6 29 187 5 8 1 E 7 560 255 47 70 28 2 161 BSLZO750C_ 712 26 006 1 2 78 C 4s 550 250 54 80 309 189 BCIZO600C 6 26 466 5 8 Ws C 45 560 255 46 70 28 2 161 BCLZO600E 2 26 466 5 8 1 C 4154 560 255 26 35 133 80 VOLTAGE KEY Based on 90 F ambient B suffix 208 230 or 230 volt 60 cycle one phase Electrical ratings for condensing unit only See National C suffix 200 230 or 208 230 volt 60 cycle three phase Electrical Code if units are combined on a single circuit E suffix 460 volt 60 cycle three phase REFRIGERATION SYSTEM TECHNICAL SPECIFICATIONS BTUH DIMENSIONS RECEIVER 10 F SIZES PUMP SHIP SUCTION en ere DOWN WT TEMP LIQUID SUCTION CAP 90 LB KG MCA MOP RLA LRA MCR 33 102 500 LB CAPACITY 1 5 HOUR PULL DOWN TIME MDLZ0331C 6 32 417 5 8 ts Ms 1
8. a si PN NREN ELECTRICAL CONNECTIONS EE DIA MOUNT INO POLES h INSIDE WEATHER HOOD 30 1 8 BASE M5 8 AIR FLOW 4 3 4 DIA LIFTING HOLES PIPING ee ZQ Q CONNECTONS pera 28 ae 47 1 4 ELECTRICAL CONNECTIONS 3 8 DIA MOUNTING HOLES 3 8 DIA MOUNTING HOLES INSIDE WEATHER HOOD 48 30 1 8 BID SPECIFICATIONS Item no MCR 33 Provide Roll in or Pass thru Blast Chiller s Master Bilt model number MCR 33 i Blast chiller to be provided with stainless steel construction and polyurethane foamed in place insulation Blast chiller will feature high velocity forced air convection through evaporator coil Probes with sequential read out display will be supplied for food temperature recording four probes in MCR 33 101 model eight in MCR 33 102 An automatic chill cycle control with food temperature probes is also supplied A thermometer will be pro vided for recording blast chiller ambient air temperature Ther mometer will require optional printer for record of tempera tures Roll in blast chillers will con tain one 30 x 78 flush mount ed polyurethane foamed door Pass thru models will contain two doors Doors will be provid ed with a 36 high 16 ga stainless steel kickplate on the exterior Doors will also be supplied with a hold open feature magnetic gas kets and gasket heater Blast chillers will be provided with an air or water cooled con densi
9. ng unit depending on ap plication requirements Blast chiller will be equipped with a standard exterior mount ed control panel featuring the following e On off switch e Digital readout of interior ambi ent temperature and probe tem peratures e Digital cycle timer for timed chilling e Microprocessor control system enclosed in easily accessible box e Automatic defrost cycle and hold cycle NOTE All specifications subject to change without notice e Audible alarm at end of chill ing cycle e Six programmable one touch preset chilling programs for easy use Blast chillers will be supplied with stainless steel racks one rack for MCR 33 101 33 101PT two for MCR 33 102 33 102PT mounted on heavy duty swivel casters Racks accommodate 26 pans 12 x 20 x 2 2 two per each of 13 ledges Each pan holds up to 10 Ibs of food for to tal rack quantity of 260 lbs Di mensions of rack are 24 2 wide x 27 deep x 685 16 high Blast chillers to have standard limited one year extended com pressor warranty optional four year extended warranty avail able with one year limited parts and limited 10 year for panels Blast chillers will be UL and C UL listed and UL EPH classified M BMASTER BILT Refrigeration Solutions E HT Standex Food Service Equipment Group 908 Highway 15 North New Albany MS 38652 PHONE 800 647 1284 or 662 534 9061 FAX 800 232 3966 or 662 534 6049 e www master bilt com
10. s2 e ie ioa aisa 20230m 9 15 OO oa MCR 33 102_ 70 98 89 1778 2362 2184 208 230 1ph 4 wire PASS T ERU PASS THRU MCR 33 101PT_ 70 52 89 1778 1194 2184 208 230 1ph 4 wire 9 15 f 1500 682 MCR 33 102PT_ 70 98 89 1778 2362 2184 208 230 1ph 4 wire 16 20 3000 1364 Depth and height include control panel SAX AX SAX SOA SALA Y Sannin SSRS NSA ESSESI we SOKO SISS NSS SOK SOK PISS 09S INSON x SSSR RSSI SOSS NSS DESICS CSSS SKIING RSSI SSS BSCS ot SOD So SS SX SN oe ESES SESSIES CSSS SSS SSS we SO at SO ee S SO YY S SO Q RSN 0A900009 BOSSRAN SESS SSS BSOS 9099S S BSS OD gS SOR RSS SRT arsetootatcatcnganatsetgatatneceng lll RINSI SOSNO we SOD SSRS SA SOD SSO RSIS ROSNO SSS 36 HIGH 16 GA STAINLESS STEEL KICKPLATE EXTERIOR OF DOOR ONLY MCR 33 101 PLAN VIEW MCR 33 101 ELEVATION VIEW MCR 33 101 SIDE VIEW SSS SS SS W SS KS et PESSOA EROS RSSI RSRSRS RSENS 36 HIGH 16 GA DOOR AVAILABLE ON EITHER STAINLESS STEEL KICKPLATE SIDE OF WALK IN EXTERIOR OF DOOR ONLY MCR 33 102 PLAN VIEW MCR 33 102 ELEVATION VIEW MCR 33 102 SIDE VIEW ENJENEN HOOKUP REA Hardwire remote refrigeration G US oM NSF ANSI 7 REFRIGERATION SYSTEM TECHNICAL SPECIFICATIONS All condensing units must include a suction accumulator Pull down time reflects time neces sary to lower listed quantity of food from 140 F to 40 F All units listed contain R 404