Home
Magellan MGDCTXP2-TI04 User's Manual
Contents
1. signal JP1 OFF Normally Closed Reed Switch Universal Input open zone closed signal closed zone open signal JP2 NOT USED JP1 OFF Normalmente Cerrado Entrada Universal de Interruptor de L mina abierto se al de zona cerrada cerrado se al de zona abierta JP2 SIN USAR English The MG DCTXP2 can support two inputs simultaneously reed switch amp universal input lt transmits two different serial numbers SN one for each input which are always SN and SN 1 e g 240 000 240 001 A switch or other security device can be connected to the universal transmitter input terminals to provide wireless transmission of the device s open closed status Powering the Unit Verify proper polarity and insert two alkaline AAA batteries After inserting batteries a power up sequence will begin 10 20 seconds during which the door contact will not detect an open zone or tamper Encendido de la Unidad Insertar dos bater as alcalinas AAA verificando la correcta polaridad Luego de haber insertado las bater as se inicia una secuencia de encendido 10 y 20 seg durante la cual el contacto de puerta no detectar una zona abierta o un sabotaje Location amp Mounting There should be at least 30cm 1ft between each transmitter and 1 5m 5ft between the transmitters and the receiver Low Battery The door contact performs a battery test
2. de faire fonctionner le produit Magellan est une marque de commerce ou une marque de commerce d pos e de Syst mes de s curit Paradox Lt e ou de ses soci t s affili es au Canada aux Etats Unis et ou dans d autres pays Tous droits r serv s Sp cifications sujettes changement sans pr avis Un ou plusieurs des brevets suivants peuvent s appliquer 6215399 6111256 5751803 5721542 5287111 5119069 5077549 5920259 5886632 Des brevets canadiens et internationaux peuvent aussi s appliquer Syst mes de s curit Paradox Lt e 2005 2006 Identification de la Commission f d rale des communications FCC KDYMGDCTXP CANADA 2438A MGDCTXP Ce dispositif est conforme la Partie 15 des r gles de la FCC Son fonctionnement est subordonn aux conditions suivantes 1 Ce dispositif ne devrait pas entra ner de brouillage pr judiciable et 2 Ce dispositif doit accepter toute interf rence re ue y compris les types d interf rence pouvant entra ner un fonctionnement ind sirable Garantie Pour tous les renseignements sur la garantie de ce produit se r f rer aux manuels de r f rence des consoles MG 6060 MG 6030 ainsi qu aux D clarations sur les garanties restreintes qui se trouvent sur le site Web au www paradox ca terms L utilisation de ce produit Paradox signifie l acceptation de toutes les modalit s et conditions de la garantie
3. et le par ex 240 001 quatre reprises rel cher deux deux fois reprises l int rieur d une seconde Cavaliers JP1 INSTALLE normalement ouvert ON commutateur lames entr e universelle ouvert signal zone ouverte ferm signal zone ferm e JP1 normalement ferm DESINSTALLE commutateur lames entr e universelle OFF ouvert signal zone ferm e ferm signal zone ouverte JP2 INUTILIS Mise sous tension de l unit En respectant la polarit ins rer deux batteries alcalines AAA Apr s l insertion des batteries l unit amorce une s quence de mise sous tension de 10 20 secondes pendant laquelle le contact de porte ne d tecte pas d ouverture de zone ni de sabotage Batterie faible Le contact de porte effectue une v rification de la batterie toutes les 12 heures Si apr s quatre v rifications cons cutives de la batterie 48 heures la tension est sous 2 3 V la DEL rouge clignote un intervalle de 5 secondes et le MG DCTXP2 transmet un signal de batte rie faible Remplacement des batteries Pour remplacer les batteries 1 Retirer les anciennes batteries 2 Appuyer sur l interrupteur de s curit et le rel cher plusieurs reprises 3 Attendre 60 secondes et r initialiser l unit Sp cifications techniques Commutateur lames avec aimant un haute sensibilit avec cart standard de 1 cm 0 4 po de l
4. MGDCTXP2 TI04 MAGELLAN Wireless 2 Zone Door Contact Universal Transmitter MG DCTXP2 v3 0 Do not cut bend or AN alter the antenna Avoid mounting the door contact near or on metal as this may affect transmission Learn Mode Learn Mode allows you to transmit the serial numbers of each input To enter Learn Mode open the cover and wait until the LED stops flashing Anti Tamper Switch Press and release the anti tamper switch once Serial Number SN Reed switch e g 240 000 Visual Confirmation The LED will flash once four times Press and release the anti tamper SN 1 Universal transmitter input The LED will flash twice rapidly four Espa ol El MG DCTXP2 puede aceptar dos entradas simult neamente entrada de interruptor de l mina y universal Transmite dos n meros de serie diferentes NS uno por cada entrada los que son siempre NS y NS 1 e g 240 000 amp 240 001 Un interruptor u otro dispositivo de seguridad puede ser conectado a los terminales de entrada de transmisor universal para obtener transmisi n No se debe cortar Modo de Aprendizaje doblar o alterar la antena Evitar ubicar el contacto de puerta cerca de o sobre parpadear metal pues esto podr a Interruptor Antisabotaje afectar la transmisi n Pulsar y soltar una vez el interruptor antisabotaje N mero de Serie SN Interruptor de lamin e g 240 000 El Modo de Aprendi
5. a aplicarse 6215399 6111256 5751803 5721542 5287111 5119069 5077549 5920259 5886632 Patentes canadienses e internacionales tambi n podr an aplicarse 2005 2006 Paradox Security Systems Ltd ID de FCC KDYMGDCTXP CANADA 2438A MGDCTXP Este dispositivo cumple con la Parte 15 de los reglamentos FCC Su operaci n est sujeta a las dos condiciones siguientes 1 este dispositivo no debe causar severa interferencia y 2 Este dispositivo debe aceptar cualquier interferencia recibida incluyendo interferencias que podr an causar un funcionamiento no deseado Garant a Para una informaci n detallada acerca de la garant a de este producto consultar los manuales de MG 6060 MG 6030 y la Declaraci n de Garant a Limitada en ingl s que se encuentra en el sitio web de paradox www paradox ca terms El uso de este producto Paradox significa la aceptaci n de todos los t rminos y condiciones de la garant a Sp cifications sujettes changement sans pr avis t Approbations en instance Pour les renseignements les plus r cents sur l approbation des produits visitez notre site Web au www paradox ca La garantie ne s applique pas aux batteries alcalines fournies avec l unit La dur e de vie des batteries varie selon le trafic dans la zone prot g e Tout changement ou toute modification apport e au produit sans l autorisation expresse de Syst mes de s curit Paradox pourrait annuler les droits de l utilisateur lui permettant
6. aimant Temps de r ponse de l entr e Fr quence RF 433 MHz ou 868 MHz Alimentation 3 0 Vc c deux batteries alcalines AAA Dur e de vie des batteries jusqu trois ans Port e repr sentative dans un Spectra 1759MG 45 m 150 pi environnement r sidentiel Consoles Magellan 30 m 100 pi MG5000 MG RCV3 et MG RTX3 60 m 200 pi Interrupteur de s curit Compatibilit MG5000 Spectra 1759MG MG 6030 MG 6060 MG 6130 MG 6160 MG RCV3 et MG RTX3 Dimensions 11 cm X 3 2 cm X 2 5 cm 4 4 po X 1 3 po X 1 0 po Temp rature de fonctionnement 0 C 49 32 F 120 F Approbationst 433 MHz Du CE FE IC 868 MHz CE Specifications may change without prior notice t Approvals pending For the latest information on product approvals visit our website at www paradox ca The warranty does not apply to the batteries provided with the unit Battery life depends on the traffic through the protected zone Changes or modifications on equipment not expressly approved by the Paradox Security Systems could void the user s authority to operate the equipment Magellan is a trademark or registered trademark of Paradox Security Systems Ltd and its affiliates in Canada the United States and other countries All rights reserved Specifications may change without prior notice One or more of the following patents may apply 6215399 6111256 5751803 5721542 5287111 5119069 5077549 5920259 5886632 Canadian and intern
7. ational patents may also apply 2005 2006 Paradox Security Systems Ltd FCC ID KDYMGDCTXP CANADA 2438A MGDCTXP This device complies with part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 This device must accept any interence received including interference that may cause undesired operation Warranty For complete warranty information on this product please refer to the MG 6060 MG 6030 reference manuals together with the Limited Warranty Statement found on the website www paradox ca terms Your use of the Paradox product signifies your acceptance of all warranty terms and conditions Las especificaciones pueden cambiar sin previo aviso t Homologaciones pendientes Para informaci n actualizada respecto a la homologaci n de productos visitar nuestro sitio web en www paradox ca La garant a no se aplica a las bater as entregadas con la unidad La vida de la bater a depende del tr fico en la zona protegida Todo cambio o modificaci n en el equipo que no haya sido claramente aprobado por Paradox Security Systems puede anular la autorizaci n del usuario para operar este equipo Magellan es una marca de comercio o marca registrada de Paradox Security Systems Ltd y de sus afiliados en Canad Estados Unidos y o otros pa ses Todos los derechos reservados Las especificaciones pueden cambiar sin previo aviso Una o m s de las siguientes patentes podr
8. e fournir une transmission sans fil de l tat ouvert ferm du dispositif Emplacement et montage Un espace d au moins 30 cm 1 pi devrait tre laiss entre chaque metteur et de 1 5 m 5 pi entre les metteurs et le r cepteur V rification de l unit 1 Effectuer une v rification de la puissance du signal avant de finaliser l installation Si la transmission est faible d placer l metteur de quelques pouces afin d am liorer la r ception 2 S assurer que les batteries sont ins r es correctement 3 Assigner le contact de porte un r cepteur Magellan 4 Ouvrir et fermer la porte fen tre assign e pour v rifier le bon fonctionnement d installer le contact de porte pres d une surface m tallique ou sur une surface stalli Interrupteur de a dE Confirmation m tallique car cela pourrait da p Num ro d s rie au nuire la transmission s curit visuelle Ne pas couper Mode d apprentissage courber ou alt rer Le Mode d apprentissage permet la transmission du num ro de s rie de chacune des entr es Pour entrer en mode d apprentissage ouvrir le couvercle et attendre que la DEL cesse de clignoter l antenne viter Appuyer sur NS Commutateur La DEL clignote l interrupteur de lames quatre reprises s curit et le par ex 240 000 une fois rel cher une fois Appuyer sur NS 1 Entr e La DEL clignote l interrupteur de universelle rapidement s curit
9. el im n Tiempo de Repuesta de Entrada input Response Time RF frequency 433MHZz or 868MHz Power 3 0Vdc Two AAA Alkaline batteries Battery life Up to three years Spectra 1759MG 45m 150ft Magellan Console 30m 100ft MG5000 MG RCV3 and MG RTX3 60m 200ft MG5000 Spectra 1759MG MG 6030 MG 6060 MG 6130 MG 6160 MG RCV3 and MG RTX3 11cm X 3 2cm X 2 5cm 4 4 in X 1 3in X 1 0in Operating temperature 0 C to 49 C 32 to 120 F 433MHz Ms CE FEIC 868MHz CE 433MHz 868MFz 3 0Vcc Dos bater as Alcalinas AAA Vida til de la bater a Hasta tres a os Alcance t pico en un ambiente Spectra 1759MG 45m 150ft residencial Consola Magellan 30m 100ft MG5000 MG RCV3 and MG RTX3 60m 200ft Meruplor antisabotaje MG5000 Spectra 1759MG MG 6030 MG 6060 MG 6130 MG 6160 MG RCV3 y MG RTX3 11cm X 3 2cm X 2 5cm 4 4in X 1 3in X 1 0in DC 249 82 a 120 HomologacionesT 433MHz Qu CE FE IC 868MHz CE Range typical in a residential environment Anti tamper switch Compatibility Dimensions Approvalst Francais Le MG DCTXP2 peut accepter deux entr es simultan ment commutateur lames et entr e universelle Il transmet deux diff rents num ros de s rie NS un pour chaque entr e qui sont toujours NS et NS 1 par ex 240 000 et 240 001 Un interrupteur ou tout autre dispositif de s curit peut tre raccord aux bornes d entr e de l metteur universel afin d
10. every 12 hours If the voltage is below 2 3V after four consecutive battery tests 48 hrs the red LED will flash at 5 second intervals and the MG DCTXP2 will transmit a low battery signal Bater a Baja El contacto de puerta efect a una prueba de bater a cada 12 horas Si el voltaje es menor que 2 3V por cuatro pruebas de bater as consecutivas 48 horas la luz LED roja parpadea a intervalos de 5 segundos y el MG DCTXP2 transmite una se al de bater a baja Testing the Unit 1 Perform a signal strength test before finalizing installation If the transmission is weak relocate the transmitter by a few inches to improve reception 2 Verify that the batteries are inserted properly 3 Assign the door contact to a Magellan receiver 4 Open and close the assigned door window to verify proper operation Replacing the Batteries To replace batteries 1 Remove the old batteries 2 Press and release the anti tamper switch several times 3 Wait 60 seconds to reinitialize the unit Technical Specifications Reed switch w magnet One high sensitivity with a standard gap of 1cm 0 4 from magnet Cambio de Bater as Para cambiar las bater as 1 Sacar las bater as usadas 2 Pulsar y soltar varias veces el interruptor anti sabotaje 3 Esperar 60 segundos para reinicializar la unidad Especificaciones T cnicas Interruptor de l mina con im n Uno de alta sensibilidad con espacio est ndar de 1cm 0 4 d
11. zaje permite transmitir el n mero de serie de cada entrada Para acceder al Modo de Aprendizaje abrir la cubierta del contacto y esperar que las luces LED dejen de Confirmaci n Visual La luz LED parpadea cuatro veces o Pulsar y soltar dos veces SN 1 Transmisor La luz LED switch twice within e g 240 001 times inal mbrica del estado de abierto cerrado el ae asaba ar A gt Aena Sita al interior de un segundo e g 240 001 r pidamente dos Ubicaci n y Montaje E Debe haber una distancia de por lo menos 30cm 1ft entre cada transmisor y 1 5m 5ft entre los transmisores y el receptor Prueba de la Unidad Instructions Instrucciones P A R 5S ECURIT Y D O X 5 Y TE M 5 JP1 ON Normally Open Reed Switch Universal Input 1 Efectuar una prueba de fuerza de la www paradox com Printed in Canada 01 2007 JP1 ON Normalmente Abierto Entrada Universal de Interruptor de L mina abierto se al de zona abierta cerrado se al de zona cerrada se al antes de terminar la instalaci n Si la transmisi n es d bil mover el transmisor tan s lo unos pocos cent metros para mejorar la recepci n 2 Verificar si la bater a ha sido insertada correctamente 3 Asignar el contacto de puerta a un receptor Magellan 4 Abrir y cerrar la puerta o ventana asignada para comprobar el buen funcionamiento open zone open signal closed zone closed