Contents
1. BUSY Red Indicates that the FFD is being accessed The LED is lit when the disk is accessed read write format and remains lit until the access is completed 45 SR 001 01 7L REV 4 0 14 of 22 rn M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 8 Troubleshooting 8 1 Built In Self Test The FFD performs a self test during power up If the test fails the green LED flashes at a rate of 1 Hz If you encounter this problem please contact your dealer or technical support 8 2 Common Problems The following sections describe common problems and their causes 8 2 1 Installing Your SCSI Host Adapter A SCSI host adapter is basically a standard PC board regardless of the bus system used For example To install a standard Adaptec 1542CF 1 Check the default values of the board and verify that they do not conflict with other devices in the PC 2 Check the I O address range the IRQ s DMA channel and the BIOS address for conflicts When using a memory manager exclude the selected BIOS address space from its memory pool When selecting all resources enter them in your list of resources 3 Install the host adapter in the PC and power it ON If you did not un install the BIOS a BIOS boot message similar to the following is displayed Adaptec AHA 2940 Ultra Ultra W BIOS v1 23 c 1996 Adaptec Inc All Rights Reserved lt lt lt Press lt Ctrl gt lt A gt for SCSI Select TM Utility gt
2. e FFD 3 5 SCSI Flash Disk Throughout the remainder of this document the FFD 3 5 SCSI Flash Disk will be referred to as FFD e 4 mounting screws M Systems part no 01 SC 034 00 If any items are missing please contact your dealer 3 Visual Inspection Before unpacking or handling a drive take all proper electrostatic discharge ESD precautions including personnel and equipment grounding Before you begin installing the FFD into your system verify the following e Ifthe shipping container appears to be damaged or water stained notify your dealer e Remove the disk from its shipping enclosure and inspect it for any damage that may have occurred during shipment If any damage is observed notify your dealer e Record the disk serial number and shipment date e Retain the original shipping enclosure and all packing material for reshipment 45 SR 001 01 7L REV 4 0 3 of 22 rn M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 4 Handling Instructions You can prolong the life of your FFD increase its reliability and prevent unnecessary damage by following the instructions listed below Failure to follow any of these instructions may void your warranty e Always take all proper ESD precautions including personnel and equipment grounding e Always operate the FFD within the environmental specifications e Always use a grounded wrist strap when handling the FFD Drives that are not installed in the sy
3. cover and turn the power ON You are now ready to install the drive under UNIX If you encounter any problems refer to Section 8 for troubleshooting information 45 SR 001 01 7L REV 4 0 10 of 22 M i M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual In order to proceed with the installation you must have Supervisor privileges on your UNIX system If you do not have these privileges contact your system administrator To install the FFD as a drive under UNIX 1 Ze DO 0 A GR Run the UNIX format utility and follow the displayed instructions Select the FFD from the list of drives Define a new drive and manually enter the drive parameters using the type option Refer to Table 5 for a list of the appropriate drive parameters Define the partitions according to your system requirements Run the format and analyze command Use the label command to partition and initialize the drive Exit the format routine Build the file system on the FFD using the UNIX makefs utility Mount the drive and place the appropriate link commands in your startup script 45 SR 001 01 7L REV 4 0 11 0f 22 rn I M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 6 Drive Parameters Most SCSI device drivers can automatically detect the total number of sectors on the FFD using the READ CAPACITY command and configure them accordingly However some older device drivers must obtain the drive geometry p
4. devices can supply TRMPWR without affecting overall system performance or causing damage to the drive or any other device on the bus If TRMPWR is not available in the system this will lead to intermittent errors and other problems TRMPWR is enabled by setting the DIP switches according to Table 3 Table 3 Termination Power TRMPWR DIP Switch Settings TRMPWR Switch 5 Enabled ON Disabled OFF I Default factory setting 5 2 4 Write Protection The FFD has an internal active write protection option The write protection WP is software implemented and the switch value is retrieved during the FFD power cycle bus device reset Toggling the WP switch must be followed by a reset to activate the write protection option Write protection disables the FORMAT WRITE WRITE EXTENDED WRITE BUFFER AND SECURITY ERASE commands but does not disable the security erase interrupt It is enabled disabled by setting the DIP switch as described in Table 4 If an attempt is made to execute the disabled commands a command returns in Check Condition status with a WP Sense Key The WP switch must be toggled before powering up the FFD Table 4 Write Protection DIP Switch Settings Write Protect Enabled Disabled 1 Default factory setting 45 SR 001 01 7L REV 4 0 7 of 22 rn I M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 5 3 FFD3 5 SCSI Flash Disk Drive Installation The FFD can be installed in a
5. devices connected to the bus If additional drives are present in the system make sure that the cable runs from device to device in a continuous manner without branches Connect a power cable from the PC s power supply to the FFD Mount the FFD into a free drive bay Close the cover and power ON the PC The host adapter s BIOS sign on message appears displaying a list of the installed devices see Figure 3 for an example of an Adaptec host adapter You are now ready to use the FFD IF you encounter any problems refer to Section 8 for troubleshooting information 45 SR 001 01 7L REV 4 0 8 of 22 rn I M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual Only internal devices SCSI device I SCSI device 0 Termination Terminated not Resistors PC SCSI terminated Installed adapter Only external devices Termination Resistors PC SCSI adapter 7 SCSI device 3 Installed p SCSI device 0 c evice Terminated LL tese Ls not hroush 44 FL terminated EE NN External Terminator Termination SCSI device 2 Resistors PC SCSI SCSI device 0 not removed adapter not terminated terminated SCSI BUS SCSI device 5 seg S e 3 Terminated External oa E Terminator gt gi gam Figure 2 SCSI Cable Connection and Termination Configuration Adaptec AHA 2940 Ultra Ultra W BIOS v1 23 c 1996 Adaptec Inc All R
6. gt gt SCSI ID LUN NUMBER 0 0 DEC DSP3085S B SD16 Drive C 80h SCSI ID LUN NUMBER 1 0 M Systems FFD 350 FMAX 5D Drive D 81h The boot up message lists all devices on the SCSI bus that are powered ON Additionally it indicates if any of the devices are disks that are supported by the BIOS 4 Power OFF the PC and install the SCSI device s If you have more than one internal device e Set up a unique SCSI ID not 7 on each of the devices e Select one of these devices to be at the end of the cable 5 Make sure that the chosen device has its termination enabled and disable termination on all other devices Termination is either enabled through one or more jumpers or by installing or removing some resistor packs on the device s PCB 45 SR 001 01 7L REV 4 0 15 of 22 Y M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual nN Attach the SCSI cable to the host adapter and to the last device Do not forget the device s power connector 7 Power ON the PC and verify that the host adapter recognizes the SCSI device 8 If the SCSI device is recognized power OFF the PC and install the next device Verify recognition for the next device and then install From this point on the system should be up and running 9 If you performed a BIOS uninstall procedure or if the host adapter has no BIOS the system will note recognize the devices until the drivers are installed 8 2 2 T
7. ANSI committee X3T9 2 defined the SCSI 1 spec as Document X3 131 1986 SCSI is now an acknowledged and very well standardized multipurpose interface in all its flavors SCSI supports a wide variety of devices including hard disks removable disks magneto optical devices tape drives printers processors WORMs CD ROMs scanners medium changers jukeboxes and communications devices Q What is SCSI 1 A SCSI 1 defined a universal 8 bit I O bus that allows connection of up to 8 devices including the host adapter Every device must have a unique ID in the range of 0 7 SCSI 1 was a high speed bus system compared to the era s existing peripheral devices Q What is SCSI 2 A Although SCSI 1 was the first approved standard it lacked various parameters and definitions This led to SCSI 2 s development and approval before SCSI 1 was even officially approved In 1986 when SCSI 1 was officially approved SCSI 2 already was far along in the development process The official SCSI 2 designation is X3 131 1994 SCSI 2 provided a better formal definition removed some oddities and obsolete items added some extensions and most importantly added the ability to double and even quadruple data transfer speed on the SCSI bus with its Fast SCSI and Wide SCSI options Q What is Fast SCSI A Fast SCSI was defined as an option with SCSI 2 Despite the tendency of the market to define Fast SCSI as different but faster SCSI Fast SCSI is
8. D 7 cannot be used as this is the host adapter The FFD uses DIP switches to set the ID in a 4 2 1 configuration The sum of the switch values determines the ID For example if you want a hard disk with ID 0 set all three switches to OFF 45 SR 001 01 7L REV 4 0 16 of 22 rn M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 8 2 4 Solving Installation Problems The problems that arise in most installations are described below Unstable Termination This occurs when there is a passive termination with Fast SCSI devices on the bus Incorrect Termination This occurs when there are too many devices terminated or when the SCSI bus cable ends are not terminated Cables Avoid using homemade short flat ribbon cables with bad contacts or cheap cables Do not mix round cables with flat cables Cable Length Ensure that the cable length is within the limit specified in the standard and avoid using cables that are too long to support the transfer rate Device ID Conflict This occurs when a new device is added with a SCSI ID identical to an existing device on the bus Missing TRMPWR This occurs when the host adapter or at least one of the devices on the SCSI bus does not supply termination power Missing Software Device Driver Some host adapters do not install support for SCSI drives as an expansion BIOS In this case load an additional driver for your operating system after the system boots Note that
9. al single ended cables prohibit use of 10MHz Q Signal Levels A Single Ended SCSI signal levels vary from 0V to 5 25V All signals are active low True is a voltage level between 0 and 0 8 V and false is a voltage between 2 and 5 25 V Differential SCSI signals conform to the EIA RS 485 interface Q What is Single Ended and Differential SCSI A There are two different electrical SCSI interfaces Single Ended and Differential SCSI Single Ended and Differential devices are not electrically compatible with each other Mixing them will destroy the Single Ended devices on the bus and possibility the differential devices e Single Ended SCSI has single ended TTL transceivers that allow up to SMHz data transfer rates with up to 6 meters cable length or up to 10MHz data transfer Fast SCSI with up to 3 meters cable length e Differential SCSI has RS 485 style transceivers that allow up to 1OMHz data transfer rate but with cable lengths up to 25 meters and with much better S N conditions Q What are Synchronous and Asynchronous Transfers A SCSI can use two handshaking modes Asynchronous and Synchronous The main difference is as follows e Asynchronous is basically a classic REQ ACK handshaking system for each data packet e Synchronous multiple REQ s can be issued before receiving ACK s thus increasing the overall transfer rate 45 SR 001 01 7L REV 4 0 21 of 22 Y M Systems m Flash Disk Pioneers How to C
10. arameters manually The physical drive parameters are only a convention and have no effect on how data is stored on the FFD Table 5 Drive Parameters Unformatted Formatted Disk Cylinders Heads Sector Bytes Disk Capacity Capacity Cylinder Sector MB of blocks 1 920 3991 FFH E64H 10H 40H 512 45 SR 001 01 7L REV 4 0 12 of 22 rn M Systems ma Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual Unformatted Formatted Disk Cylinders Heads Sector Bytes Disk Capacity Capacity Cylinder Sector MB of blocks 5 632 A8EDFFH 2A3BH 10H 40H 512 Notes 1 The memory capacity is user specified when replacing the order 2 The number of logical blocks as reported by the Read Capacity command 45 SR 001 01 7L REV 4 0 13 of 22 Y M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 7 LED Indicators and Configuration Switch Figure 4 illustrates the two LEDs located on the FFD front panel Table 6 Describes the LED color codes and status definitions J opr amm mara pi Pa Red BUSY Green POWER Figure 4 Front Panel LED Indicators Table 6 LED Status Description Status LED Color Indicator Description POWER Green Indicates that power is applied to the disk The LED remains ON if everything is okay and flashes at a rate of 1 Hz to indicate that the power up and built in self test have failed and that the disk is malfunctioning
11. ched devices and it then assigns a valid soft ID to each SCAM compliant SCSI device The SCAM master keeps this device table in non volatile memory to provide an identical ID setup for further boot processes Q What is a SCSI ID A Every SCSI device must have a unique ID on the bus For this reason most devices have three ID jumpers to set the SCSI ID from 0 7 With the exceptions of ID 0 and 7 there is no particular ID that must be assigned to a particular device type Additionally every ID can have up to seven subunits identified by a LUN Logical Unit Number enabling addressing multiple devices through a single ID Table 7 General Description of SCSI ID ID Number Description ID 7 Reserved for the host adapter IDO For a boot device usually a hard drive ID 1 Normally used for a second hard drive although it is not required ID 2 and up Used for other devices for example a CD ROM Q What is Termination and TRMPWR A The SCSI bus needs to be terminated This means that both ends of the bus must have a circuit of some sort to eliminate signal reflections that otherwise would occur from the physical ends of the bus The termination circuit requires power generally supplied by a line called TRMPWR or Termination Power on the bus Typically the TRMPWR source is the host adapter However multiple devices can supply TRMPWR without causing damage The old passive termination Alternative 1 in th
12. e SCSI 2 specification came with SCSI 1 and consisted of a 220 pull up and a 330 Q pull down resistor on each signal Active termination Alternative 2 in the SCSI 2 specification consists of a 110 Q resistor on each signal pulled up to a 2 85V reference supply 45 SR 001 01 7L REV 4 0 20 of 22 Y M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual Q What types of SCSI connectors are available A There are many different connectors for SCSI Some of them were defined with SCSI 1 and are now obsolete such as the DB 50 connector The most common connectors in use today are the 50 pin Centronics type SCSI 1 connector the 50 pin High Density SCSI 2 connector and the DB 25 connector that Apple introduced for Macintosh computers Most new host adapters and external devices use the SCSI 2 HD A Cable lengths in SCSI 1 and SCSI 2 were defined up to 6 meters maximum for a single ended SCSI bus and up to 5MH7z data rate SCSI 2 allows up to a 10cm cable stub length from the device to the main bus cable Sometimes this length is exceeded causing higher capacitive loading With Fast SCSI 2 the highest possible data rate doubled to 1OMHz in synchronous mode and the maximum cable length was halved to 3 meters A differential SCSI bus can use the full cable length up to 25 meters approx 82 feet while maintaining a maximum data rate of 10MHz This is especially important with external devices as most extern
13. ermination Configuration When configuring termination the basic rule to remember is termination is required at both ends of the SCSI chain e To install a new device as the last device on one of the sides of the complete cable you must enable termination on the device e When replacing another device that was previously at the end of the cable and is now installed on another connector on the bus you must disable termination on the device e When installing an external SCSI device in a system that has only internal devices you must disable the host adapter s termination using one of the following methods e Using software as with the newer Adaptec e By removing the terminator packs typically three near the host adapter s SCSI connector e By setting a jumper on the host adapter The situation is the same if you previously had only external devices 8 2 3 SCSI ID Configuration When configuring the SCSI ID first locate a free SCSI ID The most effective method is to look at the host adapter boot up message and check for free IDs Adaptec AHA 1540CF 1542CF BIOS 2 01s c 1993 Adaptec Inc All Rights reserved Press lt Ctrl gt lt A gt for SCSISelect TM Utility Target DEC DSP3085S B SD16 Drive C 80h Target UANTUM LP425S 606_ Drive D 81h Q Target TOSHIBA CD ROM XM 3301T S DI ASERSTOR E5 Target In this example ID 2 5 and 6 are free for new devices I
14. ights Reserved lt lt lt Press lt Ctrl gt lt A gt for SCSI Select TM Utility gt gt gt SCSI ID LUN NUMBER 0 0 M Systems FFD 350 FMAX 5D Drive D 81h Figure 3 BIOS Sign On message 45 SR 001 01 7L REV 4 0 9 of 22 rn M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 5 3 2 Using the FFD on a DOS Based Platform After physically installing the FFD it must be installed as a disk drive under DOS Run the DOS commands listed below and follow the instructions displayed for each command For more information regarding the DOS commands refer to your DOS manual To install the FFD as a disk drive under DOS 1 Run the DOS FDISK program to partition the FFD If you want the FFD to be a bootable drive run Set Active Partition using the FDISK utility 2 Run the DOS FORMAT command to high level format the FFD 3 If you want the FFD to be a bootable drive run the DOS SYS command Note Some SCSI host adapters require the installation of a device driver to access SCSI disk drives In this case follow the instructions included with your adapter to configure the system and install the FFD as another drive under DOS 5 3 3 Using the FFD on a UNIX Based Platform Most UNIX systems come preconfigured with a SCSI host adapter and a hard disk already installed on the SCSI bus Follow the instructions below to install the FFD in your system If a platform does not have room for additional dri
15. ny mounting position in the system Unlike rotating disks that have an axis of rotation the FFD is not susceptible to damage due to orientation Note It is not necessary to perform a low level format on the FFD The drive is shipped low level formatted and ready for use 5 3 1 Installing the FFD in a PC If your SCSI host adapter is not installed in the system follow the installation instructions supplied with the adapter before proceeding with the FFD installation detailed below Most SCSI adapters include a BIOS expansion that allows the system to boot from the FFD after it is properly configured and high level formatted In addition the BIOS expansion automatically installs support for the FFD and assigns it a drive letter for use under DOS or other operating systems To install the FFD 1 Power down the PC and remove the cover 2 Check the adapter s memory I O and IRQ settings and verify that they do not conflict with any other devices installed in the system 3 Configure the FFD s DIP switch settings according to the information provided in Section 5 2 4 Verify that the SCSI bus is properly terminated Refer to Figure 2 for termination configuration options 5 Connect a 50 pin ribbon cable between the FFD and the adapter Make sure to orient the cable so that pin of the FFD is connected to pin 1 of the host adapter Neither the host adapter nor the FFD must be at the physical end of the cable unless they are the only two
16. ontact Us Internet E mail USA Office M Systems Inc 8371 Central Ave Suite A Newark CA 94560 Phone 1 510 494 2090 Fax 1 510 494 5545 Taiwan Office Room B 13 F No 133 Sec 3 Min Sheng East Road Taipei Taiwan R O C Tel 886 2 8770 6226 Fax 886 2 8770 6295 China Office 25A International Business Commercial Bldg Nanhu Rd Lou Hu District Shenzhen China 518001 Phone 86 755 519 4732 Fax 86 755 519 4729 FFD 3 5 SCSI Flash Disk User Manual http www m sys com info m sys com Japan Office M Systems Japan Inc Arakyu Bldg 5F 2 19 2 Nishi Gotanda Shinagawa ku Tokyo 141 0031 Phone 81 3 5437 5739 Fax 81 3 5437 5759 Europe Israel Office M Systems Ltd 7 Atir Yeda St Kfar Saba 44425 Israel Phone 972 9 764 5000 Fax 972 3 548 8666 M Systems assumes no responsibility for the use of the material described in this document Information contained herein supersedes previously published specifications on this device from M Systems M Systems reserves the right to change this document without notice e mail support m sys com 45 SR 001 01 7L REV 4 0 22 of 22
17. ot the FFD shares the SCSI bus with additional drives After doing this assign an unused ID to the FFD If the FFD is the only device on the SCSI bus the ID should be left at the factory default 0 To select the required ID set the DIP switches according to Table 1 45 SR 001 01 7L REV 4 0 5 of 22 YY M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual Table 1 SCSI ID DIP Switch Settings I Default factory setting 5 2 2 Termination The SCSI bus must be terminated at the two physical ends of the cable Only the devices connected at either end supply terminations Devices that are not located at the end of the cable must have their terminations disabled otherwise they will cause a degradation of the signal quality Too many terminations will cause intermittent errors or other problems when accessing devices on the SCSI bus If the FFD is the last device on the cable then the terminations must be enabled by setting the DIP switch according to Table 2 Table 2 Termination DIP Switch Settings I Default factory setting 45 SR 001 01 7L REV 4 0 6 of 22 rn M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 5 2 3 Termination Power TRMPWR Termination power must be supplied by at least one device on the SCSI bus it is normally supplied by the host adapter However if you are unsure whether TRMPWR is available in your system you can configure the FFD to supply TRMPWR Note that several
18. rn I M Systems mm Flash Disk Pioneers Section ll User Manual FFD 3 5 SCSI Flash Disk MARCH 2002 45 SR 001 01 7L REV 4 0 rn I M Systems mo Flash Disk Pioneers Table of Contents FFD 3 5 SCSI Flash Disk User Manual TE Generals 3 2 Kit Contents iii did wali dd 3 3 MVis dl AIS GC CONN it Le 3 4 Handling Instructions Luse ete 4 Stalin 5 5 System Requirements dd it dd 5 52 FFD 3 5 SCSI Drive Comiquera iia 5 A AS A eee ng re et 5 5 22 Terminationi ut arne da erme eide bid ee 6 5 2 3 Termination Power TRMPWBR rsnnrrrnnronnrrnnronnrrnnnrnnrrnnnenrrnnrenrrennsnnrrensensrnensennnrrnnnennrnensennnn 7 5 2 4 Wite Protec iia aske ed teke kratere 7 5 3 FFD 3 5 SCSI Flash Disk Drive Installation senere 8 5 3 1 Installing the FFD ina PG s erarnvenonrvnrrrrrnnnrrnnnnvnnenrvnrnrrrannrnnnnnvenenrennnrrnennnnnsnnennsrresnnrnsennnenennennnee 8 5 3 2 Using the FFD on a DOS Based Platform rernrrannvnnnnnvnnnnvvnnnrrvnnnrnnnnnrnnrnvenrrrrerrnrnnennnenenreeenn 10 5 3 3 Using the FFD on a UNIX Based Platform ersnnrrnnnonnrrnnnnnnrrnnnnnnrrnnrrnnrrenrennrrnnrennrrnnrrnnrrnnrennn 10 6 Drive Para MEterS ii e e desir 12 6 O O o esser 12 7 LED Indicators and Configuration SwitCh rrnrnnnnnvvvvnnnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnen 14 BB TOUTS SOO UNA Gis ea a Bi Stes ia 15 8 1 B ilt In Self TEST nara da evi desde EEEIEE EARE aurea dees Er bereder renerne 15 8 2 COMMON Problems sat
19. simply an additional synchronous data transfer mode with tighter timing to achieve the 10MB sec maximum data rate As with any other synchronous transfer mode only data transfers are synchronous while commands are transferred asynchronously Q What is Wide SCSI A Wide SCSI is another SCSI 2 option There are two defined types 16 bit and 32 bit Wide SCSI can be combined with Fast SCSI to provide up to a 40MB sec data rate The X3T9 2 committee defined a 68 pin SCSI cable for the 16 bit type and a combination of a standard 8 bit A and a 68 pin B cable for 16 bit and 32 bit Wide SCSI Wide SCSI host adapters can address standard SCSI devices if the correct adapter cable is used 45 SR 001 01 7L REV 4 0 19 of 22 rn M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual Q What is Plug and play P amp P SCSI A Plug and play SCSI is an extension of the generic plug and play specification P amp P is an approach for defining an auto configuring environment for ISA boards One of the key features of P amp P SCSI is SCAM Q What is SCSI Configured AutoMagically SCAM A SCAM is a protocol for automatic SCSI ID assignment It is included in the SCSI 3 parallel interface drafts The SCAM master typically the host adapter scans the bus for attached SCSI devices For compatibility it also needs to find and identify legacy standard SCSI devices This scan provides the SCAM master with a map of the atta
20. stem are sensitive to ESD damage e Always handle the FFD carefully e Never apply DC power to the drive by plugging an electrically live source cable into the drive s power connector 45 SR 001 01 7L REV 4 0 4 of 22 Y M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 5 Installation 5 1 System Requirements In order to install the FFD in your system ensure that you have the following items e System mounting hardware e 4 pin power cable e 50 pin ribbon SCSI cable e SCSI host adapter e Appropriate device driver for your operating system and SCSI host adapter 5 2 FFD 3 5 SCSI Drive Configuration Before mounting the drive in the system drive bay you must configure the FFD by setting the DIP switches on the front panel to meet your system requirements Any changes to the DIP switch settings must be done while the FFD is powered OFF otherwise the FFD may be damaged or the new settings may not be recognized Figure 1 shows the orientation of the DIP switches Note that the numbers are displayed upside down However the order of the DIP switches correspond correctly to the numbers printed next to each switch A A ve A Red BUSY Green POWER Figure 1 Front Panel DIP Switches 5 2 1 SCSIID Every device on the SCSI bus must have a unique SCSI ID You must ensure that the SCSI ID of the drive is not the same as the host adapter typically ID 7 and to ascertain whether or n
21. t eens narnia denied A tent dato A A ad 15 8 2 1 Installing Your SCSI Host Adapter cccceececeeeeeeeeeeeeeeeeeeeeeeeceaeeeeeaeeeeeeeseeeesaeeseaeeneaeeseeeeess 15 8 2 2 Termination Configuration cccccccccecceeeeeeeeeeceeeeecaeeeseneeceeeeeceaeeeseaeseeeeeseaeeesaeeseaaeseeeeeeeaeee 16 8 2 3 SCSI ID Configuration i ea Er ENE er DR aa raa aaa nr Re RE 16 8 2 4 Solving Installation ProDlIOMs ccccceceeeeseeceeeeeeeeeeeeaeeeeeeeseeeeecaaeeeeeaeeeaaeseeeeeseaeeesaeeseaeeseeeeee 17 9 Getting Help canis keene eee ee ee eh ee ee 18 10 Frequently Asked Questions FAQs About SCSI rrrrrrrrrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnr 19 How 10 Contact US dica 22 45 SR 001 01 7L REV 4 0 2 of 22 rn M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 1 General This manual provides you with the information you need to properly install your new FFD 3 5 SCSI Flash drive M Systems recommends that only properly qualified and trained personnel install the drive The following sections contain information about handling mounting considerations address and configuration setups cabling and connectors and how to obtain technical assistance and service In addition Section 10 provides answers to common questions regarding SCSI devices Note Remember to always back up your data before adding disk drives to your system 2 Kit Contents Ensure that your kit contains the following items
22. this configuration cannot boot from the SCSI drive 45 SR 001 01 7L REV 4 0 17 of 22 M m Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 9 M Systems Getting Help For technical assistance with the installation and configuration of your FFD contact one of the sources listed below Please have the following information available to aid the customer support representative in providing you with the best possible guidance Product and serial number of your FFD Description of your computer hardware manufacturer model attached devices etc Description of your SCSI host adapter and associated drivers Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages Before contacting M Systems directly first contact your dealer If your dealer cannot provide the help you need you can obtain technical support from M Systems directly at one of the numbers listed at the end of this manual 45 SR 001 01 7L REV 4 0 18 of 22 rn M Systems mua Flash Disk Pioneers FFD 3 5 SCSI Flash Disk User Manual 10 Frequently Asked Questions FAQs About SCSI Q What is SCSI A SCSI Small Computer System Interface is a general purpose parallel bus system It originated with Shugart s 1979 SASI Shugart Associates System Interface and Shugart and NCR presented it to the ANSI in 1981 It became official in 1986 when the
23. ves an external unit is required to mount the FFD External units typically include a 3 5 drive bay power supply and cables WARNING Installing any disk drive on a UNIX system is a very complex procedure If you are not an expert consult your system administrator for help Failure to do so can lead to loss of data on existing drives in the system Refer to your UNIX documentation for more details regarding the installation procedure for SCSI disks under UNIX To install the FFD in a UNIX based platform 1 Power down the system 2 Configure the FFD s DIP switch settings according to the information provided in Section 5 2 3 Verify that the SCSI bus is properly terminated Refer to Figure 2 for termination configuration options 4 Connect a 50 pin ribbon cable between the FFD and the adapter Make sure to orient the cable so that pin 1 of the FFD is connected to pin 1 of the host adapter Neither the host adapter nor the FFD must be at the physical end of the cable unless they are the only two devices connected on the bus If additional drives are present in the system make sure that the cable runs from device to device in a continuous manner without branches Note that some systems require a cable with two different types of connectors one for the FFD and one to interface with the system s host adapter 5 Connect a power cable from the system s power supply to the FFD 6 Mount the FFD into a free drive bay 7 Close the