Home

Lux Products T10-1141 (discontinued) Instruction Manual

image

Contents

1. Time Monday through Friday The number is 1 900 884 1000 and the cost is 1 50 per minute WARRANTY Limited Warranty If this unit fails because of defects in materials or workmanship within one year of date of original purchase Lux will at its option repair or replace it This warranty does not cover damage by accident misuse or failure to follow installation instructions Implied warranties are limited in duration to one year from date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Please return malfunctioning or defective units to the participating retailer from which purchase was made along with proof of purchase Please refer to Technical Service Section before returning thermostat Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit Some states do not allow the exclusion of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Applicable in the U S A only
2. Do not locate in a damp or humid area This can shorten thermostat life due to corrosion 5 Do not locate where air circulation is poor such as in a corner alcove or behind an open door 6 Do not install until all construction work and painting have been completed 2 TOOLS REQUIRED Wirestripper or knife drill with 16 bit screwdriver level and a pencil 3 REMOVING OLD THERMOSTAT Please read all instructions carefully As you complete each step check the adjoining square Disconnect electricity and turn off gas to the heater Remove cover from old thermostat Loosen all screws Disconnect wires from thermostat making sure they do not fall back inside the wall Strip insulation s from wire ends and clean off any corrosion Fill wall opening with non combustible insulation to prevent drafts from affecting thermostat 4 Ae fet NEW THERMOSTAT Place new decorative wall plate if supplied Figure 3 over wall opening Decorative wall plate can optionally be left off O Remove Front Cover of new thermostat by inserting a finger in the side of the thermostat and gently prying away each corner Place Base Figure 2 on wall plate over wall opening Mark wall with pencil at mounting holes as shown in Figure 2 Now lay wall plate and base to the side Drill two holes with 3 6 bit 1 deep Insert plastic screw anchors into drilled holes flush with wall surface __Bring wires through large hole in decorative wall plate and throu
3. INSTALLATION AND OPERATING INSTRUCTIONS 110 1141 HEATING ONLY THERMOSTAT 43214 Rev B Bia eso 50 e 60 70 80 90 a Sn SPECIFICATIONS ELECTRICAL RATING cecceceeeeeeeeeeee 24 Vac 30 Vac Maximum SWITCH ACTION ccccccccssescsessssssersesseesseseees Sealed Mercury Switch ANTICIPATOR RATING ccccescsssscsessssssssesscsssssrssesesseees 0 15A to 1 2A TEMPERATURE RANGE lt siusiu 00 F to 90 F INSTALLATION amp OPERATION 1 THERMOSTAT LOCATION For accurate temperature control and comfort correct location is very important On new installations the guidelines listed below should be followed as closely as possible When replacing an old thermostat install the new one in the same location unless these conditions suggest otherwise 1 Locate the thermostat on an inside wall about five feet above the floor where it is easy to install and adjust It should be in a room that is used often such as a family room 2 Do not install it where there are unusual heating conditions such as direct sunlight close to a lamp radio television radiator register near a fireplace or other heat producing appliance Also check for hot water pipes within the wall or a stove on the other side of the wall 3 Do not locate in unusual cooling conditions such as on an outside wall or one separating an unheated room or in drafts from stairwells doors or windows 4
4. gh Hole For Wires in Base Fasten Base loosely to wall using two mounting screws Place a level against the bottom of the Base adjust until it is level and then tighten mounting screws to secure the Base O Attach wires to terminal screws shown in Figure 2 Either w wire to either terminal Push excess wire back into wall opening Find anticipator setting on old thermostat Setting on new thermostat should be the same Do this by carefully sliding the long pointer on the anticipator over the desired number If old anticipator setting cannot be determined look on gas control on furnace or set it at 6 During heating season furnace should operate about five times an hour If adjustments are necessary move heat anticipator pointer slightly and recheck NOTE Set pointer to 1 2 for millivolt systems Attach front cover Figure 1 to base Turn electricity and gas back on and set pointer on top of thermostat to desired temperature Met alse el Ie a FIGURE 1 tee FRONT COVER BASE MOUNTING HOLES ANTICIPATOR LONG POINTER HOLES FOR WIRES TERMINAL SCREWS FIGURE 3 DECORATIVE WALL PLATE If you have any problems installing or using this thermostat please read the instructions carefully Technical Service is available through our 900 telephone service If you require assistance please call our offices between 9 00 a m and 4 30 p m Eastern Standard

Download Pdf Manuals

image

Related Search

Related Contents

二重構造高精度レーザーフォト治療育毛ブラシ取扱説明書 【育毛ブラシ    Hart Interface Programs User Manual  OMER1/2 Postworkshop Proceedings  Information de produit KNORR® al Formaggio 0.78 kg  AVN-G。ー  

Copyright © All rights reserved.
Failed to retrieve file