Home

Lux Products ELV1 (discontinued) Instruction Manual

image

Contents

1. Open the drop down door on the front of the thermostat Rotate the dial to the SET DAY TIME position You should see the display pictured above with a flag pointing to a day of the week flashing When you are finished setting the day and time rotate the dial to RUN to return to normal operation or to another position to continue programming To change To set current time The To change the current day time e g 12 00 AM current time will be flashing TEMPERATURE OVERRIDE AND TEMPERATURE HOLD These features let you change the current Set Temperature without changing the programs stored in your thermostat s memory Temporary Temperature Override e Press UP DOWN to change the current temperature setting The OVERRIDE indicator appears on display e The Override feature will be automatically canceled at the start of the next program period e To cancel OVERRIDE prior to next program period press UP DOWN until original set temperature appears OVERRIDE indicator will d i s a p p e a r from display VACATION Temperature HOLD e Press HOLD Adjust temperature as desired with UP DOWN Temperature setting will not change even after next program period begins e To clear press HOLD again ADVANCED FEATURES TEMPERATURE SWING A thermostat works by turning your heating on and off whenever the room temperature varies a certain number of degrees from the set point temperature This variation is the swing
2. them as you wish Each day is 1O00 PNT 62 divided into four periods Each period has its own starting time The dial must be in the RUN position to and temperature close the door Programming the thermostat You can change any of the preset times and or temperatures to suit your schedules for the weekday and weekend programs Each day is divided into four periods Morning Day Evening and Night A blank programming chart is provided for you to record your temperature settings in that chart MORN DAY EVE NIGHT Rotate dial to SET WEEKDAY PROGRAM To program the WEEKEND rotate the dial to SET WEEKEND PROGRAM With dial on set WEEKDAY Program you will see this display om pigge poe or i To program temperature ver To program temperature To change the temp To change the temp DOWN Gx setting for MORN setting for EVE To move to DAY To move to NIGHT Down To change start time To change the start em for DAY time for NIGHT To program temperature Cex To program temperature To change the temp To change the temp D setting tor DAY j setting for NIGHT To move to EVE Rotate dial to RUN position to start the programs Setting the TIME and DAY c A U T l o N om i The thermostat is protected against normal static electric g 200 discharges However in extremely dry weather you should ed 3 mi touch another metal object before the thermostat to avoid potential loss of programs
3. Your system should cycle on about 3 to 6 times per hour A smaller swing number increases the number of cycles so room temperature is more constant A larger swing number decreases the number of cycles to save energy in most cases SWING SETTINGS Press together Dial must be in To change Gas Leh wor the run position ae 4 Cer Press to set CHANGING FROM F to C AND A 12HR CLOCK TO A 24HR CLOCK e Warning Making these changes will require you to reset the thermostat Copy any of your customized programs onto the chart below This will be your reference to reenter the programs afterward e Located at the center of the circuit board of your thermostat are two dip switches e To change to Celsius move the top dip switch to the right e To change to a 24HR clock move the bottom dip switch to the right e Press the reset key on the front of the thermostat for the changes to take effect e Reprogram as necessary COPYRIGHT 2004 LUX PRODUCTS CORPORATION ALL RIGHTS RESERVED PROGRAMMING CHART MONDAY through FRIDAY SATURDAY and SUNDAY TECHNICAL SERVICE If you have problems installing this thermostat please reread the instructions carefully Be sure the batteries are good and installed correctly Press the RESET button if erratic operation is encountered If you still have problems call Technical Service at 1 856 234 8803 between 8 00 a m and 4 30 p m Eastern Standard Time Monday through
4. Friday or visit our online technical support at www luxproducts com Please refer to Model ELV1 or PSPLV510 WARRANTY Limited Warranty If this unit fails because of defects in materials or workmanship within one year of date of original purchase LUX will at its option repair or replace it This warranty does not cover damage by accident misuse or failure to follow installation instructions Implied warranties are limited in duration to one year from date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Please return malfunctioning or defective units to the participating retailer from which purchase was made along with proof of purchase Please refer to Technical Service Section before returning thermostat Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit Some states do not allow the exclusion of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Applicable in the U S A only
5. compartment 3 Remove the used batteries if necessary 4 Install two new Energizer or DURACELL AA size alkaline batteries in the battery compartment Observe the polarity marking shown in the compartment 5 Place the battery compartment back in the thermostat 6 Close the door Note If this is the first time you are installing batteries the thermostat will display SUN 12 00 AM Within 90 seconds the thermostat will begin to display the room temperature alternately with the time To correct the display see SETTING THE TIME AND DAY COPYRIGHT 2004 LUX PRODUCTS CORPORATION ALL RIGHTS RESERVED OPERATION This thermostat is armchair programmable You can make any program or setting changes with the thermostat body off or on the wall thermostat base The thermostat alternately displays the current time and the room temperature It also displays the day of the week and the currently active control program that is controlling the temperature MORN DAY EVE or NIGHT The set point temperature will appear in the right side of the display The Built In Programs Push in the RESET key This PERIOD HEAT sets the built in heating ae Ee WEEKDAYS 6 00 AM 70 programs To review the built in programs rotate the dial to SET salad poe a i WEEKDAY PROGRAM or SET nee WEEKEND PROGRAM You can use the built in 6 00 AM 70 programs as shown or change WEEKENDS 8 00 AM 62 preprograms 6 00 PM 70
6. Check the old insulation for cracks nicks or fraying and apply certified electrical tape where necessary to achieve adequate insulation or replace the wires in an approved fashion 4 Attach the wires with solderless wire connectors provided Be sure that all wire connectors are tight COPYRIGHT 2004 LUX PRODUCTS CORPORATION ALL RIGHTS RESERVED 1 Thermostat Heater CAUTION Do not short the 120 240 Vac wires with the thermostat This will damage the thermostat and void the warranty WARNING To avoid the risk of fire hazard all connections to aluminum conductors must be made using approved CO ALR solderless wire connectors Do not use the supplied solderless wire connectors 5 Bend the solid conductors then push them and the wire connectors into the electrical box Secure the thermostat base to the electrical box with the mounting screws 6 Snap the cover in place 7 Turn the power on WARNING Use Energizer or DURACELL Alkaline Batteries Only INSTALLING BATTERIES en caer ee The thermostat requires batteries to operate your furnace and retain its programming in memory Replace the batteries when the LO BAT indicator appears in the display or at least once a year NOTE When replacing batteries you have approximately 1 minute before the programs are lost 1 Remove the fresh batteries from their package 2 Open the front door of the thermostat and tilt out the battery
7. INSTALLATION INSTRUCTIONS FOR ELV1 PSPLV510 Programmable Line Voltage Thermostat LUX PRODUCTS CORPORATION Mt Laurel New Jersey 08054 USA 43331 04 WARNING Use Energizer or DURACELL Alkaline Batteries Only Energizer is a registered trademark of Eveready Battery Company Inc DURACELL is a registered trademark of The Gillette Company Inc For Use On e Heating Only 120 240 Vac Single Pole Applications e Baseboard Ceiling Cable and other Radiant Heat Not For Use On e Double Pole Applications e Heating Cooling or Cooling Only e Low Voltage 24Vac Systems Electrical Rating 16A at 120 240 Vac 1900W at 120Vac Non Inductive 3800W at 240 Vac Non Inductive Temperature Differential e 1 F Factory Preset Adjustable Batteries e Two Energizer or DURACELL AA alkaline batteries not included Programming e Preprogrammed 4 Periods per day e 5 2 Programming e Weekdays Weekends can be different e F C Changeable e Temporary Temperature Override e Vacation Hold Dimensions 47 Tx2 7 Wx 2 4 D e 1 4 D from wall surface Wall Plate e 4 8 W x 5 0 H Wallplate Included INSTALLATION WARNING e This Thermostat is a line voltage 120 240 Vac control Do not install it unless you are completely familiar with house wiring If improperly handled there can be a risk of electric shock hazard which may cause serious injury or death e The thermostat is
8. rated for normal full load current on a dual residential 20A circuit breaker or fuse block Do not use on circuits protected by higher rated over current protection devices Some sustained fault conditions can cause product failure e Do NOT connect to voltage different from the device rating CAUTION e Disconnect power supply before making wire connections to prevent electrical shock or equipment damage e All wiring must comply with applicable codes and ordinances e Thermostats are designed to be used with appliances having a limit control e Maximum load for this thermostat MUST NOT EXCEED 3800W otherwise a potential fire hazard exists Location Install a vertical switch box for mounting the thermostat approximately 1 5 m 5 ft above the floor on an inside wall where the thermostat will be exposed to average room temperature The thermostat must be placed away from concealed warm or cold water pipes air ducts or drafts from hallways fireplaces or stairways to sense temperature properly Do not place the thermostat above the heater WIRING 1 Disconnect power while installing Double check that the thermostat is rated for the voltage and amperage load to be controlled 2 Remove the cover by carefully pressing the button at the bottom of the thermostat and swinging the body up and away 3 When replacing an old line voltage wall thermostat remove it carefully to avoid damage to the insulation on the wiring