Home
Lumiscope 1095 User's Manual
Contents
1. ON INFLATION UP TO TWICE AS FAST as traditional monitors thus eliminating the pain and discomfort com monly felt with traditional styles Smartinflate Technology measures the Diastolic low pressure first and Systolic high pressure last by adjusting the amount of pressure during the measurement based on arm size and normal blood pressure fluctuations Unlike the traditional oscillometric measurement process that first pressurizes the cuff then slowly releases the air from the cuff to record a measurement Smartinflate Technology eliminates errors caused by users movement during measure ment The Diastolic pressure is taken in a practically natural state without any arterial compression and the Systolic pressure is taken with minimal arterial compression resulting in more accurate measurements reduced measurement time and without pain or discomfort Battery Installation Replacement e To use the unit you must install batteries e Open battery cover and slide back as illustrated Install or replace four new batteries making sure the polarities and on the battery match the polarities on the case e Replace battery cover e Replace the batteries if the Low Battery indicator appears on the display the ON OFF START button is pressed and nothing appears on the display e AAA alkaline batteries or equivalent are recommended for this blood pressure meter The 1095 can be used either attached to the aff
2. E All memories will be deleted when batteries are replaced Description of Display Marks DISPLAY MARK CONDITION CAUSE CORRECTIVE ACTION Blood pressure could not be measured accurately Exhaust all air from the cuff Reapply the cuff properly Repeat measurement Batteries are weak Replace the batteries Device malfunction Return to Lumiscope Service Department Specifications Model No 1095 Measuring Principle Oscillometric M ethod Measurement Localization Left Upper Arm Cuff Soft Cuff Arm Circumference Range 8 66 tol2 6in 22 to 32 cm Measurement Pressure 20 to 280 mmHg Range Pulse 40 to 180 Pulses min Pressure 3 mmHg Accuracy Pulse 5 of reading Pressure Systolic blood pressure 3 digits L LCD Pulse Rate Diastolic blood pressure 3 digits 4 sive ndicati n Pulse rate 3 digits Marks Pulse Rate Battery Switch ON OFF START and MEMORY button Inflation Pump Driven Exhaust Electromagnetic Valve Power Source 4 AAA Size Batteries Alkaline Power Consumption 3W Battery Life Approx 700 times 170mmHg 1time day Automatic P ower Off Approx 1 min after last measurement Memory Function 60 Memories Dimension 2 9 W x 5 12 D x 1 32 H in 73 x 128 0 x 33 H mm Weight Approx 10 6 02 300g excludes battery Operating Temperature 50 to 104 F 10 to 40 C Environment Humidit
3. LUMISCOPE Blood Pressure Monitor Advanced Technology Measures While Inflating Instruction Manual Model Number 1095 ID 08 01 Requires 4 AAA Alkaline Batteries 2 LIMITED WARRANTY TABLE OF CONTENTS Identification OT Pats aceasta Ee ha HO Ra 3 Battery Installation Replacement 0 000 eee ee 4 Preparing to Use the Monitor Using the Monitor Attached to the Arm Cuff 0 0 0 0 0 eee 5 USMO dsa labletop MONO 2020200660006 ia Rainaa aie A 2 Attaching the Arm Cuff and Posture During Measurement 2 at eee eed eee a TEDRE EEE 6 Measurement scaa 4i dee eee ee aa Vale Khe hag eae RO 7 Subsequent Measurement uaaa a ee 8 Automatic Power OFF Function 000 eee eee eee 8 Memory Recall Function 1 0 es 8 Description of Display MarkS auauna 9 SGC IGA OLS axe ike hy S25 se Aatse ee Gs acy he etd sah AR ae toe Sah ea we ae a 10 NV OVE te 4 ih faces Sat gs Arava NGG Se ea atta AN Gia Se eee Mee anes Saat ae at 11 Identification of Parts Peg Release Button over ON OFF START Am Cuff Button with Air Plug Air Tube Air Plug Air Plug to cuff to monitor QO CO CO 4 AAA size Release Button Connector Alkaline Banene Smartinflate Technology Thank you for purchasing the Lumiscope 1095 Comfort Line Blood Pressure Monitor A state of the art line of blood pressure monitors that MEASURE
4. e changing values of the cuff pressure will be shown on the display These numbers are for reference only and do not represent your final Blood Pressure reading When the pressure reaches your systolic blood pres Sure the monitor will exhaust cuff pressure When the monitor completes the measurement cycle it will automatically display the systolic diastolic and pulse readings After the measurement value is displayed press the ON OFF START button to turn the monitor off i TT g lt 5 Subsequent Measurement When a second measurement needs to be made the time between two measurements should be at least teb minutes Automatic Power OFF Function If unit is left on after measurement an ON OFE Automatic Power OFF Function turns the START power off after approximately one minute To continue with another measurement press the ON OFF START switch to turn the unit on Memory Recall Function e Stores the last sixty readings in sequential order 1 60 When sixty first reading is taken the oldest recorded measurement 1 is delet ed e Press MEMORY to recall the last measured blood pressure reading e Each time you press the MEMORY button it will recall the next previous set of readings e The memory function does not work during auto matic inflation or while blood pressure measure ments are being made All readings stored in memory will be displayed with its sequence number NOT
5. e the terms of this warranty the consumer may seek breach of contract remedies in the New York State Federal courts of law This warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you 2 LIMITED WARRANTY The Lumiscope Company Inc Service Dept 122 Tices Lane East Brunswick N J 08816 TEL 1 800 672 8293 www lumiscope net
6. or as a table top monitor with the endosed airtube attachment Preparing to Use the Monitor Using the Monitor Attached to the Arm Cuff Angle the bottom of the monitor against the raised part of the plastic piece on the cuff fig A e Line up the holes on the back of the monitor with the pegs on the plastic piece of the cuff e Push the monitor onto the cuffand make Sure it is Securely fastened e Now you can use the monitor while it is attached to the cuff fig B Using as a Tabletop Monitor e To release the monitor from the cuff press and hold the release button on top of the monitor and pull the monitor away from the cuff Connect the monitor end of the air tube to the holes on the back of the monitor fig C e Connect the cuff end of the air tube to the peg on the plastic piece of the cuff fig D Push the connection into the cuff until you hear a clicking sound e Now you can use the monitor as a desk top unit fig E NOTE To detach the air tube from the main unit simply press and hold the release button while pulling the tube connection away from the unit Attaching of Arm Cuff and Posture During Measurement Ce Unfasten and open the cuff as shown in the fig g ure leaving the Index end of the cuff through Fig F the D ring fig F Wrap the arm cuff around the upper left arm firmly so that bottom edge of the cuff is posi tioned about one inch above the elbow join
7. t Position the cuff so that the artery mark is in the middle of the arm in line with the middle finger fig E e Wrap the cuff as close to the skin as possible Do NOT roll shirts or jackets up over the arm when taking a measurement This will constrict the upper arm and prevent accurate measurement e When using the monitor attached to the cuff the monitor and artery mark should be on the inside of your arm fig H e When using the monitor as a tabletop unit the cuff tube should be placed on the inside of your arm fig e Make sure that the cuff is fastened firmly Note that wrapping the cuff unevenly will prevent proper meas urement Rest left elbow on a table so that the cuff is at heart level Relax the lower arm across the table and remain still Perform measurements in either a seated or reclining posture with the left palm turned upward Fits Arm Circumference 8 66 to 12 6 inches NOTE If the Index line falls within the OK range indicated along the upper edge of the cuff this cuff is suitable for your use If the Index line falls out of the OK range con tact the Lumiscope Service Dept for an Oversize cuff model 109 235 Measurement e Press the ON OFF START button ON OFF START All display symbols will appear for approximately one second before the display returns to 0 The unit will automatically start to inflate slowly measuring your blood pressure During inflation th
8. y 40 to 85 RH Storage Temperature 23 to 140 F 5 to 60 C Environment Humidity 10 to 95 RH Two Year Limited Warranty The Lumiscope Company Inc guarantees this product free from defects in material and workmanship for a period of two years from the date of purchase except as noted below This Lumiscope product warranty does not cover damage caused by misuse or abuse the attachment of any unauthorized accessory alteration to the product or any other conditions whatsoever that are beyond the control of the Lumiscope Company Inc Lumiscope shall not be responsible for any type of incidental consequential or special damage All implied warranties including but not limited to those implied warranties of fitness and mer chantability are limited in the total duration of two years from the original date of purchase To obtain warranty service on your Lumiscope Blood Pressure Meter either hand deliver or mail the entire unit and your dated sales receipt as proof of purchase postpaid along with a certified check or money order in the amount of 15 00 payable to The Lumiscope Company Inc to cover handling Upon receipt Lumiscope will repair or replace as appropriate Blood Pressure Meter and return to you Warranty is solely through Lumiscope Repair Department Service of this product by anyone other than Lumiscope Repair Department voids warranty In the event that Lumiscope does not abid
Download Pdf Manuals
Related Search
Related Contents
User Manual - AirStation WHR-G54S Wireless Cable/DSL Samsung P2250N Benutzerhandbuch 医薬品・医療機器等安全性情報287号 MP3 User Manuel Kensington Foot Rest Black HT910 E Terminal User Manual C-BLACKMAGIC BLACK MAGIC Notice d``utilisation Manual de Multimetro con Termometro IR User manual Copyright © All rights reserved.