Home

Linksys Tribox SPA400 User's Manual

image

Contents

1. 0 like any other trunk To add an outbound router eg dial 9 to dial out the SPA400 Outbound Routes gt Add Route Route Name SPA400PSTN this can be anything Route Password Blank Emergency Dialing Unticked Intra Company Route Unticked Dial Patterns 9 Trunk Sequence SPA400 Click Submit Changes Step 7 Configure Inbound Route This will setup an inbound route for people who call the PSTN lines plugged into the SPA400 Setup gt Inbound Routes gt Add Incoming Route DID Number SPA400 case sensitive Caller ID Number Blank Zaptel Channel Blank Fax Handling Leave as IS Select the Destination Click Submit Click the Red Apply Configuration Changes to reload asterisk Complete You should now be able to make and receive calls via your SPA400 Email Ssupport voipshop com au for further support if required Congratulations Notes SPA400 IP Address SPA400 Username SPA400 Password Number of Lines
2. Linksys SPA400 Access oint Trixbox Integration Guide trixbex LINKSYS A Division of Cisco Systems Inc Access Point Connecting You amp Your Customers Contact support voipshop com au Overview The Linksys SPA400 is a 4 Line FXO gateway capable of connecting 4 PSTN lines to your asterisk system to make and receive calls This guide is a step by step on how to configure Trixbox to utilize the features of the SPA400 Limitations The voicemail function of the SPA400 cannot be used You cannot select which line of the SPA400 to use They are treated as a single group of 1 4 lines The SPA400 will know which lines are available by the line voltage when plugged in Configure the SPA400 Step 1 Obtain the IP address if the SPA400 Option 1 Easiest You will need to check your DHCP server to see what IP address has been allocated to the SPA400 Will usually be in the Status area of your Modem Router Option 2 Harder If you only have a few devices on your network you can use angry IP scanner http www angryziber com which will search your network for devices You should be able to work out the SPA400 address Try searching for port 5060 also to help identify Option 3 You can download the SPA9000 setup utility from http www linksys com it will scan the network for SPA400s and show the IP address Note the IP Address Step 2 Access the SPA400 In your favourite web browser type the IP address of th
3. e SPA4OO it Should ask for a username and password The default username is Admin Note capital A The default password is blank Firmware Version 1 0 0 7 4 Port FXO VoIP Gateway Setup Administration Status Event Logs Basic Setup SPAQO00 Interface Voice Voicemail Server Voicemail Users Network Setup Dynamic IP Address DHCP Client FixedIP Address 192 168 1 56 en Ee Step 3 Set the SPA400 to a Fixed IP address Asterisk needs to access your SPA400 so it needs to be set to a fixed ip address To do this Under Setup gt Basic Setup e Select Fixed IP address and enter a valid fixed IP address for your network e Be sure to enter a DNS server if you do not know enter the Telstra DNS server 139 130 4 5 You can leave the secondary blank e Set your time zone e Click Save Settings e Restart System Setup Administration Status Event Logs Basic Setup SPA9000 Interface Voice Yoicemail Server Voicemail Us Network Setup O Dynamic IP Address DHCP Client Fived IP Address a92 168 fi IP Subnet Mask 255 255 255 lo fz da Gateway IP Address 192 168 Imain Name Server DNS Address Secondary DNS NTP Server time nist gov Time Fone CGMT 10 00 Australia we Save Settings Cancel Changes Sample Config Use Address Valid For Your Network Check with the network administrator if unsure Note the IP address in the N
4. ettings Transmit Gain Receive ain Impedance 220 Ohime 820 Ohime 120 nF Tipping voltage 3 5 defaut Operational loop current Min 10m detant On Hook speed Jms Australa Ring frequency tein ele o o 2 Q mn ma lt Ring frequency Wax Ring Validation Time 256 defaut Ring Indication Delay S12 defaut me Ring Timeout m B40 defaut Ring Threshold vrmei 13 5 16 5 detaut Ringer Impedance High detautt Dl current Limiting Enable defaut c 4 Caller ld Method O Battery reversal as disconnect signal Loop period shut down as disconnect signal Step 5 Configure Trixbox Trunk Open your FreePBX interface http trixbox ip admin Select Trunks gt Add SIP trunk Complete the form with the details below Outbound Caller ID Blank Never Override CallerlD Unticked Maximum Channels the number of pstn lines plugged into the SPA400 Dial Rules Leave Empty Outbound Dial Prefix Empty Trunk Name SPA400 Can be anything you wish Peer Details allow ulaw Ccanreinvite no context from trunk dtmfmode rfc2833 host x X X X insecure very type friend user SPA400 USER Context Leave Blank USER Details Blank Delete the default information Register String SPA400 x x X x SPA400 Note x x X x should be where you enter the IP address of the SPA400 Click Submit Changes Step 6 Configure Outbound Route You can now treat the SPA40
5. otes Section Step 4 Setup the SPA400 Voice Configuration Open the SPA400 in your web browser using the new IP address Select Setup gt SPA9000 Interface e Enter SPA400 in the User ID e Leave SPA9000 on discover automatically e No other changes should need to be made e Click Save Settings You Do Not Need To Restart SPA9000 User ID User ID P A400 SPAI00 Address Discover Automatically 2 Static Address P Address 92168070 Port oso Port ID Port ID 1 FXO Port_ID_1 Port ID 2 FXO Port_ID_ Port ID 3 FXO Port_ID_s Port ID 4 FXO Port_I gt _ 4 signaling Signaling Port S060 RTP RTP Port 10000 IP Tos Diffserv Call Signaling Packets 2 Hex digit byte value RTP Packets bo 2 Hex digit byte value session Enable Session Timer Desired Refresh Time Sec Minimum Retresh Time sec o o Save Settings Cancel Changes Screenshot of Setup gt SPA9000 Interface Select Setup gt Voice For Australia you need to change e Impedance 220 Ohms 820 Ohms 120nF e On Hook speed 26ms Setup Administration Status Event Logs Basic Setup oi Voicemail Server voicemail U Preferred Coder oa 7441 Oars OaG729 Voice Coders Packetization VAD Calling Timers VWWeit forAnevver time sec all Limit ZEC Dialing Parameters Tone out on IN ec Tone out oft NSEC DTMF power 400 30 0 1 dB Anewver after rings Dial out wait NSEC Dial out battery threshold volts Line S

Download Pdf Manuals

image

Related Search

Related Contents

HX720U - Yaesu.com  E 5019 300 00059 TABLA DE PROGRAMAS  Philips 200CW8 Computer Monitor User Manual  Harbor Freight Tools 94344 User's Manual  testo 550 · Analizador de refrigeración digital  

Copyright © All rights reserved.
Failed to retrieve file