Lightolier IS:CCLPS602P User's Manual
Contents
1. Lightolier Lytemode DMX color rotary dial or DMX 512 compatible controllers Fig 9 Examples of Sequential and Reverse Addressing Note Reverse addressing only reverses the addresses on Output 1 of the CCLPS602P Group Address Set to 1 10 9 2 1 1 2 Group Address Set to 1 2 3 0 f i 24V Class 2 UL cUL CE PSE 12 20 6 36 9 20 9 20 Example 1 When using a Rainbow Wash with sequential addressing group address set to 1 the luminaire flows from the center the first luminaire on Output 1 to the last luminaire in Output 1 and then back to the first luminaire on Output 2 When using a Rainbow Wash with reverse addressing group address set to 1 the luminaire flows from left to right across all fixtures The luminaire goes from the last fixture on Ouput 1 to the first fixture on Output 1 and then to the irst fixture on Output 2 to the last fixture on Output 2 CCLPS602P Center Feed Installation Base Address 1 Set to 1 Group Address Set to 1 1 2 20 40 22 Group Address 39 40 Group Address Set to 1 Group Address Set to 1 Example 2 Reverse addressing allows you to have a continuous Rainbow Wash when you have an installation fed by more than one power supply When using sequential addressing on both power supplies the luminaire flows from the first luminaire on Output 1 of the first power supply to the ast luminaire on Output 1 lef
2. output Otherwise you may have a smaller amount of luminaires at the end of each output port that would receive the next address 4 Use the DOWN button to set reverse addressing Note CCLPS602P allows you to reverse the addressing sequence on Output 1 ONLY Using reverse addressing the last luminaire on Output 1 receives the Base Address and then the addresses are assigned sequentially from the last uminaire to the first Reverse addressing is particularly useful if you mount your power supply in he center of a linear feed or if you want to feed an installation that uses multiple power supplies from each side Use reverse addressing to chase from one end of the luminaire run to the next See Fig 9 for examples Use the DOWN button to set a negative group number according to the fol owing table Set a negative group number to use reverse addressing 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group A0908 PHILIPS LIGHTOLIER Page 4 of 4 Architectural Decorative IS a C C LPS602 P Instruction Sheet for Assembly and Installation Group How Luminaires Are Addressed Address All luminaires are addressed sequentially starting with the Base Address If you have 20 luminaires with a Base Address of 1 they are addressed as follows Ligt 12345678 Address 20 19 1817 1615 1
3. the IEC power cable to the back of unit Plug the IEC power cable After mounting the power data supply you are ready to connect power lumi into a standard 100 240VAC outlet Tighten the screw to secure the clamp naires and data to CCLPS602P See Fig 5 Connecting Luminaires to CCLPS602P Note If power supply does not power up front display is blank make certain e Plug the leader cable connector into a power output receptacle on the front power cable is firmly inserted into the receptacle on the back of the unit of CCLPS602P Power outputs are labeled Out 1 and Out 2 See Fig 2 Note When using one luminaire run per CCLPS602P use Output 1 Fig 5 Tighten Screw To Luminaires To Lock e Refer to the user guide for your luminaires to determine maximum number of luminaires per power data supply and specific wiring requirements Connecting DMX Data CCLPS602P receives DMX data from and can be controlled by Lightolier s full line of DMX512 controllers or any third party DMX512 controller e Plug the data RJ 45 connector from the controller into the DMX IN port e To daisy chain DMX data to another CCLPS602P connect a CAT5 cable with RJ 45 connectors between the DMX OUT port of the first unit and the DMX IN port of the next unit Plug a terminator into the DMX OUT port of the last power supply in a data chain See Fig 3 To Luminaires To Luminaires Lightolier DMX or Color Rotar
4. 4 13 Power Input Power Output 18 19 20 Heat Dissipation 3 2 5 To exit Configuration mode press both buttons simultaneously The base address for CCLPS602P will appear on the display CCLPS602P Specifications 100 240VAC 50Hz 60H7z 1 1 0 4A 24VDC 62W Max 22 of total power input at maximum load Ambient Operating Temp 14 F to 122 F 10 C to 50 C Every two luminaires are assigned the same address For example if Housing 8 8 22 4 cm X 4 0 10 2 cm X you have 20 luminaires with a Base Address of 1 they are addressed 2 0 5 1 cm as follows PEN light 12345678 18 1920 Weight 2 0 Ibs 307 g Address 10 10 998877 2 11 Connectors Data RJ45 input and output connectors Every three luminaires are assigned the same address For example if you have 20 luminaires with a Base Address of 1 they are ad dressed as follows 1 2 77 18 19 20 Address Data Input Interface Data Output Interface Classification Listings Max of Luminaires Note It is recommended that you set your group number to a number that evenly divides the number of luminaires connected to Output 1 and you balance the number of luminaires on each output Otherwise you may have a smaller amount of luminaires at the end of each output port that would receive the next address Power 4 pin output connectors IEC power con nector Supplied with C13 IEC plug grounded US outlet plug UL CSA rated 18 AWG 3 C ST 90 C Rated
5. LIGHTOLIER Page 1 of 4 Architectural Decorative IS a C C LPS602 P Instruction Sheet for Assembly and Installation Read and understand these instructions before installing luminaire This luminaire is intended for installation in accordance with the National Electrical Code and local regulations To assure full compliance with local codes and regulations check with your local electrical inspector before installation To prevent electrical shock turn off electricity at fuse box before proceeding Retain these instructions for maintenance reference Getting Started CCLPS602P is a compact power data supply for indoor installations CCLPS602P provides power and data to Lightolier concealed color lighting product lines and is available for DMX and Ethernet control options The s type of power supply provides additional features such as base address and grouping of luminaire addresses without the need for external components This instruction guide contains important information on installing and using your new CCLPS602P Please read it carefully and save it for future reference Included In This Box e Power data supply e US Grounded IEC Power Cord Set e RJ 45 Terminator e Instruction Sheet Additional Items Needed e Mounting hardware 4 flat head screws M3 5 or 6 Scope of this Instruction Guide The goal of this user guide is to explain the steps necessary to install CCLPS602P for DMX and Ethernet control to assure pe
6. ak performance Its intended use is for reference only by persons who are fully qualified This docu ment should never be considered a substitute for any provisions of a regulation or state and or local code Identification and Warnings of Safety Hazards In accordance with ANSI Z535 4 2002 the following system identifies the sever ity of the hazards associated with the products Danger Imminently hazardous situation which if not avoided will result in death or serious injury Warning Potentially hazardous situation which if not avoided could result in death or serious injury Caution Potentially hazardous situation which if not avoided may result in minor or moderate injury or property damage Also used to alert against unsafe practices Ignoring a hazard will void any warranty Warning Ensure that power is disconnected before installing wiring or servic ing the CCLPS602P power supply Warning The CCLPS602P power supply must be installed by a qualified profes sional in accordance with NEC and relevant local codes Warning Do not attempt to install or use CCLPS602P until you read and under stand the installation instructions and safety labels Warning Do not use CCLPS602P if power cables are damaged Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules This equipment generates uses and can radiate radio frequ
7. ency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to take adequate measures Caution Ensure that CCLPS602P is securely attached properly mounted and free of excessive vibration Caution Do not hot swap Ensure the power supply is off before connecting or disconnecting luminaires Caution Do not modify or alter CCLPS602P Lightolier is a Philips group brand Note The instructions and precautions set forth in this installation guide are not necessarily all inclusive or relevant to all applications as Lightolier cannot anticipate all conceivable or unique situations Owner User Responsibilities It is the responsibility of the contractor installer purchaser owner and user to install maintain and operate CCLPS602P in such a manner as to comply with all state and local laws ordinances regulations and the American National Standards Institute Safety Code Note CCLPS602P is shipped with a US IEC power cord For international cus tomers use a country specific IEC cable meeting the following specifications 3 conductor 18AWG 1 00mm2 HAR rating for Europe and JET rating for Japan Hard Service Type ST or equivalent Note Ensure the IEC inlet plug fits in the supplied lock The lock may not accom modate a
8. ll plug styles Installation CCLPS602P must be installed by a qualified electrician in accordance with NEC and relevant local codes for power supplies A power screwdriver is recom mended for mounting the unit Mounting the Housing e Select the location to mount the housing keeping CCLPS602P within the maximum distance specified for your luminaire Refer to your luminaire user guide for the cable run information Caution CCLPS602P must be installed in a location that allows air to move freely Packing insulation around the housing or mounting in a sealed location that raises ambient temperature above 122 F 50 C may result in property dam age and may void the warranty Note Ensure that there is adequate space to make all connections to the front and rear of the unit e Mount the housing to a flat surface using four M3 5 or 6 flat head screws suitable for the mounting surface Mounting slots are located on each end of the housing See Fig 1 Note Do not overtighten the mounting screws 21 2 cm 5 7 cm 2 25 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group A0908 PHILIPS LIGHTOLIER Architectural Decorative IS a C C LPS602 P Page 2 of 4 Instruction Sheet for Assembly and Installation Wiring Connecting Power e Connect
9. s connected to Output 2 the maximum group number is 10 To set grouping of luminaire addresses 1 Press and hold the UP and DOWN buttons simultaneously to enter configura tion mode CFG appears in the display 2 When entering Configuration mode CCLPS602P automatically discovers all luminaires that are connected 3 Use the UP button to set a positive group number the number of luminaires per group according to the following table ALL luminaires are assigned the selected Base Address If you have 20 luminaires with a Base Address of 1 they are ad dressed as follows Ligt 12345678 18 19 20 Address 11111111 1 44 All luminaires are addressed sequentially starting with the Base Address If you have 20 luminaires with a Base Address of 1 they are addressed as follows Light 123456 456 7 8 18 19 20 Address 1 2 3 7 8 18 19 20 Every two luminaires are assigned the same address For example if you have 20 luminaires with a Base Address of 1 they are addressed as follows Light 18 19 20 Address Every three luminaires are assigned the same address For example if you have 20 luminaires with a Base Address of 1 they are addressed as follows Light 3 45 Address lea ay 78 33 6 2 Note It is recommended that you set your group number to a number that evenly divides the number of luminaires connected to Output 1 and you balance the number of luminaires on each
10. t to right and then it flows from the first uminaire on Output 1 of the second power supply to the last luminaire on Output 1 right to left a g c CCLPS602P DMX Ethernet Base Address 1 Using reverse addressing on the second power supply allows you to set up the flow from left to right across all fixtures With this setup the luminaire flows from the first luminaire on Output 1 of the first power supply to the last luminaire on Output 1 and from the last luminaire on Output 1 of the second power supply to the first luminaire on Output 1 CCLPS602P DMX Ethernet Base Address 21 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group A0908 Lightolier is a Philips group brand PHILIPS
11. ted and addresses them sequentially beginning with the base address on the first luminaire on Output 1 through the last luminaire on Output 2 This step ensures that the unit correctly identifies all of the luminaires connected to its outputs After the discovery is complete two 3 digit numbers are briefly displayed The first digit indicates the output port and the last two digits denote the number of luminaires connected to that output For example the number 107 represents 7 luminaires on Output 1 while the number 213 indicates 13 lumi naires on Output 2 If there are no luminaires attached to an output the last two digits are 00 as in 200 See Fig 8 10 7 outer NUMBER OF LIGHTS e lJ Fig 8 EXAMPLE 13 LIGHTS ON OUTPUT 2 3 To exit Configuration mode press both buttons simultaneously The base address for the unit will appear on the display Lightolier is a Philips group brand Instruction Sheet for Assembly and Installation Grouping Luminaire Addresses CCLPS602P allows you to conserve the total number of luminaire addresses in an installation by grouping luminaires together When you group luminaire address es you can assign multiple luminaires to the same address The number of lumi naires per group is limited to the maximum number of luminaires connected to Output 1 For example if you have 10 luminaires connected to Output 1 and 12 luminaire
12. y Dial Controller 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group A0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Architectural Decorative IS a C C LPS602 P Page 3 of 4 Addressing the Luminaires When using the DMX control input you are required to set the base address for the unit and configure the luminaires connected to it The base address for the supply will be the starting address for the first luminaire connected to Output 1 You can also group more than one luminaire to the same address or reverse the addressing sequence of the luminaires on Output 1 Setting Base Addresses 1 Press and release the UP or DOWN address buttons to step through the base address The address numbers 1 through 170 will appear in the display Press and hold either button to rapidly advance to the desired luminaire number Stop when the desired base number appears on the display See Fig 6 Fig 6 UP 3 Digit Display 2 After selecting a base address press and hold the UP and DOWN buttons simultaneously to enter configuration mode CFG appears in the display See Fig 7 Fig 7 CONFIGURATION MODE LEL When entering Configuration mode the unit automatically discovers all lumi naires that are connec
Download Pdf Manuals
Related Search
Related Contents
Additional User guide/upgrade information. GE PSC23SGN Side by Side Refrigerator Sony PCGA-DDRW1 Operating Instructions D.Lgs. 9-4-2008 n. 81 Trust Raina 2.1 Honeywell SmartLine EU Meter Users manual, 34-ST-25-18 LEYBOLD DIDACTIC GMBH Mode d`emploi 337 47 337 471 337 HF3476, HF3475 Copyright © All rights reserved.