Home

Lightolier IS:1055LV User's Manual

image

Contents

1. IN PLACE BEFORE ENERGIZING LAMP AND THAT GREAT CARE MUST BE TAKEN THAT LAMP IS FULLY COOLED BEFORE RELAMPING AVOID FINGER MARKS WHEN HANDLING FOR THEY MAY CAUSE SHORT LAMP LIFE AND POSSIBLE BREAKAGE oee VERTICAL ANGLE ADJUSTMENT AND LOCK Fig J LAMP LAMP SPRING 9 Insert a screwdriver into the LOCKING GUIDE on the E LAMP YOKE HOLDER and locate the siot in the VERTICAL ADJUST LOCK SCREW turn the SCREW counterclockwise and using the screwdriver as a lever tilt the entire LAMP YOKE HOLDER to the desired angle Once the desired angle is reached tighten screw by turning screwdriver clockwise HORIZONTAL ADJUST AND LOCK Fig J GLASS LAMP GUARD 10 The entire LAMP YOKE HOLDER can be horizontally FIG rotated to aim the ange of light as it leaves the hole in the APERTURE TRIM Fig J This can be done by backing off the HORIZONTAL ADJUST LOCK SCREW one full turn freeing the SUPPORT PLATE Fig J LAMPIYOKE r Grasping the YOKES on either side of the HOLDER Viner Ais LAMP LAMP YOKE HOLDER rotate the SUPPORT PLATE oon aama a to the desired angie and lock the position by SUPPORT PLATE pod gt SOCKET tightening the HORIZONTAL ADJUST LOCK SCREW ra k RELAMPING The locking mechanisms designed within this fixture allow relamping without having to readjust and i E relock Follow Steps 5 8 tp NOTE 1 LOW VOLTAGE FIXTURES should be f dimmed only with special dimmers Intended fa specifically
2. ING into the other SLOT Fig F FIG E 4 PUSH UP Fig D SOCKET CUP Push REFLECTOR TRIM into ceiling until flange is flush to ceiling Fig D RECTANGLE HOLE FRAMING KIT MOUNTS FLUSH ON CEILING MATERIAL CEILING St MATERIAL ROTO CLIP POSITION NOTE Socket manufacturers have suggested that SLOTS TAB socket may fail after 3 to 6 relampings If this occurs socket can be replaced by disconnecting REFLECTOR TRIM male connectors attached to socket leads from female connectors attached to fixture leads and F SOCKET replacing it with a new socket procured through Lightolier Fig G MALE CONNECTORS ATTACHED TO SOCKET WIRE INSULATING SLEEVING SEE BACK PAGE FOR LAMP INSTALLATION AND ADJUSTMENT FEMALE CONNECTORS ATTACHED TO FIXTURE WIRES MR16 SOCKET FIG G TO HE2 SECAUCUS NEW JERSEY 07096 i I C gt l i a i om Gm MONTREAL QUEBEC CANADA IS 1055LV 0890 LAMPING INSTRUCTIONS AND ADJUSTMENTI LOCKING eee eke INSTALL LAMP 5 Remove LAMP RING from LAMP YOKE HOLDER by UNOLDER pulling straight down Fig H 6 Insert LAMP MR 16 between LAMP SPRINGS unti ip of LAMP sits firmly on GLASS LAMP GUARD ig I 7 Attach SOCKET to bi in prongs on LAMP Fig 1 8 Insert LAMP RING with LAMP and GLASS LAMP fa dy attached back into LAMP YOKE HOLDER Fig J UIA LAMP SPRING LAMP RING WARNING LAMP MANUFACTURERS REQUIRE THE QUARD FIG H GLASS LAMP GUARD BE
3. INSTRUCTION SHEET NO INSTALLATION PROCEDURE FOR LOW VOLTAGE i REFLECTOR TRIM IN THE 1000LV FRAME IN KIT i 4 55 0890 Page 1 of 2 READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE This fixture is intended for installation in accordance with the National Electrical Code and local regulations To assure full compliance with local codes and regulations check with your local electrical inspector before installation To prevent electrical shock turn off electricity at fuse box before proceeding Retain these instructions for maintenance reference FIG A FIG B FIG C FIG D 1 FRAME IN 2 CLOSE IN 3 SNAP ON 4 PUSH UP WARNING BEFORE INSTALLING REFLECTOR TRIM TO FRAME IN KIT READ MARKINGS IN REFLECTOR TRIM AND IN SOCKET CUP OF FRAME4N KIT TO DETERMINE LAMP WATTAGE AND TYPE APPLICABLE FOR YOUR INSTALLATION IF I C TYPE FRAMING KIT IS USED IT MAY BE INSTALLED IN DIRECT CONTACT WITH INSULATED CEILINGS IF A NON I C TYPE FRAME IN KIT IS USED DO NOT INSTALL INSULATION WITHIN 3 INCHES OF FIXTURE SIDE OR WIRING COMPARTMENT NOR ABOVE FIXTURE IN SUCH A MANNER TO ENTRAP HEAT 1 FRAME IN Fig A See Frame in Kit Instruction Sheet for installation procedure i 2 ROTATE ROTO CLIPS Fig B As shown in Fig E 3 SNAP ON Fig Insert SOCKET through RECTANGLE HOLE on top of REFLECTOR TRIM Engage TAB from SOCKET CUP into one of the SLOTS on top of REFLECTOR TRIM and push other end of SOCKET CUP with LANC
4. for that purpose Use Lightolier j Lytemode Scenist Crescendo VA Neptune VA Precision VA Easyset VA Sunrise VA Radiant VA or P equivalent products by others or variable auto Ne transformers or electronic dimmers intended for use Y 3 YOKE VERTICAL with low voltage fixtures 2 Low voltage fixtures may Y ff aii ADJUST LOCK produce audible sound when used with external HORIZONTAL anne SCREW dimmers which may be objectional in acoustically ADJUSTILOCK H KING GUIDE critical areas LOC FIG J WARNING USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER INC USE OF OTHER MANUFACTURERS REFLECTOR TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD

Download Pdf Manuals

image

Related Search

Related Contents

Operating Instructions OS3 Base unit, VC830100  CA ARCserve Replication and High Availability  RoomMate 26” & 32” Programming Manual  Viewsonic Projector PJ755D  Manuale di installazione e manutenzione  Extricom WLAN System Installation and User Guide  DYMATIZE - ELITE XT  ATP-SP303 取扱説明書  Complete catalogus - Volvo Accessories  COD. 28180 USER MANUAL - HAND SUCTION UNIT  

Copyright © All rights reserved.
Failed to retrieve file