Home
Lightolier EG1-13 User's Manual
Contents
1. Light Option gt 2 Light Option T Tandem Switching also available in 1 lamp configuration A B Both Dual Switch and Tandem Switch fixtures ship with a 4th wire Be sure to order the appropriate quantity of wires in the power feed Lightolier is a Philips group brand Feature Options continued E Emergency Battery Pack E Battery packs provide 90 minutes of opera tion Available lamp outputs 450 Lumens standard Optional 635 1100 and 1375 Lumens Standard Emergency wiring is to have Battery Pack operating a single lamp All EM fixtures are wired as switched and include 4th through wire for the wall switch see diagrams All fixtures and power feeds in that run should be ordered to include a dedicated 4th through wire to carry the hot power all the way through the run to the EM pack Wall Switch Unswitched Switched Job information tee 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 PHILIPS LIGHTOLIER Page 3 of 4 Fixture Lengths amp Mounting Locations 4 121 92cm Run 8 243 84cm Run 12 365 76cm Run 16 487 68cm Run 20 609 60cm Run 24 731 52cm Run j 48 121 92cm gt 5 152 40cm OA je 96 243 84em t
2. hae 094 Degree a By 1 80 1863 75 1865 ee 65 1800 E 55 1673 ig 45 1476 ag 35 1234 i 3 25 952 Le 15 645 679 1 05 336 med p Pa 95 69 1358 7 re 90 0 ge Z 85 12 ayl 7 gt 3 75 ba 65 168 215 7 o 55 315 0 45 501 35 646 Report No EG1 13 GQ ies 25 755 Lamps 3 FP54 835 HO 15 821 Lumens 4450 5 854 Efficiency 90 2 CEN o Cat No EG13GQAL 25 C Rating Ballast and Lamp Ordering Combinations Coefficients Of Utilization Desgn Lamp Type Ballast Ballast ma r 0j T8 or T5 Factor BF THD Wattage FM T5 1 lt 10 28 FN T5 1 lt 10 28 FO 15 1 lt 10 28 GP HO 1 lt 10 54 GQ HO 1 lt 10 54 GR HO 1 lt 10 54 IM T5 DIM 1 0 01 lt 10 28 IN T5 DIM 1 0 01 lt 10 28 10 T5 DIM 1 0 01 lt 10 28 JP T5HO DIM 1 0 03 lt 10 54 JO T5HO DIM 1 0 03 lt 10 54 JR T5HO DIM 1 0 03 lt 10 54 Notes 25 C Rating All data is per 1 lamp on a two lamp system at 277 VAC Data is based When ordering no lamps provided by Lightolier use Lamp code Z Do not alter lumen values or ballast factor light losses when completi 22 45 67 90 Candelas 863 1863 1863 1863 881 1911 1922 1950 946 2140 2264 2320 975 2312 2526 2620 931 2388 2569 2571 817 2156 2200 2224 Gly Wes 2 2 61 1863 2509 2647 892 1554 1669 1638 431 457 486 394 0 0 0 0 20 25 28 27 10 127 135 127 230 244 264 255 364 364 379 386 499 468 482 473 637 606 578 57
3. 48 121 92cm 96 243 84cm 9 274 32cm OA 13 396 24cm OA je 96 243 84cm w t 96 243 84cm Lighting Systems EG1 13 Energos 3 Light T5 per 4 121 92cm Nominal Lens 4 121 92cm Run 8 243 84cm Run 12 365 76cm Run 16 487 68cm Run 20 609 60cm Run 24 731 52cm Run 48 121 92cm gt nH T 17 518 16cm OA 96 243 84cm r 96 243 84cm 4 121 92cm Module 1 21 640 08cm OA j 96 243 84cm gt 96 243 84cm 8 243 84cm Module wW NN 96 243 84cm gt End Set 1 1 1 1 1 1 25 762 00cm OA Suspension and End Set Ordering Illustrations Power Feeds Consult Lamp and Ballast System data to determine input watt requirements for ballast used on project to determine loading for each run Multiply the total num ber of ballasts by the input wattage per ballast and to determine ampacity divide the total watts by the system voltage 10 Amps for 3 wire end sets 7 Amps for 4 wire and 5 wire end sets maximum Power Feed End Set White 3 Wire Cord White 4 Wire Cord White 5 Wire Cord Aluminum 3 Wire Cord Aluminum 4 Wire Cord Aluminum 5 Wire Cord Ceiling Grid Kit CGK Control Cable Joiner mem Consult appropriate ECS Energos Control Systems specification sheet for ordering pr
4. 6 752 757 722 697 817 826 837 840 859 855 845 837 854 854 854 854 Lamp Lamp Rated Color ie aia Output Kelvin 2600 830 2600 2600 835 2600 2600 84 2600 4450 830 4450 4450 835 4450 4450 84 4450 2600 830 2600 26 2600 835 2600 26 2600 84 2600 26 4450 830 4450 134 4450 835 4450 134 4450 84 4450 134 on Osram Sylvania Specifications ng calculations using Energos IES files n a Lighting Design program will be Files have already been adjusted The lumen value for the lamp withi the IES Output value shown on this table Lightolier is a Philips group brand Effective Ceiling Cavity Reflectance 80 70 50 Wall Reflectance 50 30 10 50 30 10 50 30 10 Mw So Sid as a i sis is 1 78 75 72 69 66 64 52 50 48 2 2 68 63 59 60 56 52 45 43 40 3 60 54 49 53 48 44 40 36 34 z 4 538 46 41 47 41 37 35 32 29 S 5 47 40 35 42 36 31 32 28 24 s 6 2 Wa SB Bia me a 7 38 31 26 33 28 24 25 21 18 Bisa 27 23 si 2a Al a 9 31 24 20 27 22 18 21 17 14 IO 22 5 Ao 1G S ie 20 Floor Cavity Reflectance Distribution Zone Lumens Lamp Luminaire 0 90 2385 16 18 90 180 11152 74 82 0 180 13536 90 100 System System System Input Efficiency Lamp Life Start Type Watts lum watt Hours 31 0 83 9 20000 Program 31 0 83 9 20000 Program 31 0 83 9 20000 Program 58 5 76 1 20000 Program 58 5 76 1 20000 Program 58 5 76 1 20000 Program 33 5 8 77 6 A Program 2578 77 6 A Program 33 5 8 77 6 NA Program 63 12 5 70 6 A
5. LIGHTOLIER Page 1 of 4 i Lighting Systems EG1 13 Energos 3 Light T5 per 4 121 92cm Nominal Lens O 5 59cm 11 27 94cm ES 4 Feature Specifications Electrical Connections Wiring is via 18 gauge wire All electrical connections for standard configurations are plug and play via 6 wire cannon plug connections Connections are seated in end castings of fixtures allowing for simultaneous mechanical elec trical coupling Connectors are male female therefore modules must be installed male to female starting from the power feed end set Male Female All static ballasts have the following features e Electronic e High Power Factor e Class A sound rating e Metal can Emergency Battery Pack Emergency Battery packs are designed to operate when normal building power is interrupted The battery packs operate for a mini mum of 90 minutes without any power via a rechargeable battery source The pack does not utilize the standard static ballast for any of its operation since the pack carries its own pseudo ballast For this reason Lightolier does not recommend remote mounting EM Packs because all of the socket wiring would need to carry throughout the powerfeed end set The EM batteries even in their largest most expensive form operate the fluorescent lamps at only half the lamp rated output Emergency battery packs are available in the following outputs e 450 Lumen
6. Program 63 12 5 70 6 A Program 63 12 5 70 6 A Program Job information tee 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 PHILIPS
7. ess steel aircraft cable accomplishes suspension and is adjustable from 12 30 48cm to 36 91 44cm Power feed is 18 gauge SJT silver braided cord with a clear jacket For special circuiting consult factory Finish Powder coated baked enamel white or aluminum as specified Custom colors available consult factory Ordering Instructions Individual Fixtures 1 Order number of MODULES required 2 Order one POWER FEED END SET per MODULE Continuous Rows Determine run length Order the appropriate number of MODULES for the complete run Order one POWER FEED END SET for each run Order one CABLE ASSEMBLY per MODULE minus one per run For runs that exceed conductor ampacity ratings order the appropriate number of SINGLE CABLE amp CORD SETS ma Aaa Job Information Job Name Cat No Lamp s Notes 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 PHILIPS LIGHTOLIER Lighting Systems EG1 13 Page 2 of 4 Energos 3 Light T5 per 4 121 92cm Nominal Lens Module Ordering Information Family Series Lamping amp Ballast Lamp Shielding Length Voltage Finish Options Distribution Blank EG 1 3 L 3 3 Lamp See Ballast See Lamp L Duplex 4 4 121 92cm 1 120V A Aluminum 4 4 through wires Open To
8. oduct utilizing occupancy controls ECS specification sheet numbers directly cor relate to standard Energos specification sheet numbers Cable Cord Assembly EG1EC36W Single Cable amp Power Cord EG1EC36W4 Single Cable amp 4 Wire Power Cord EG1EC36W5 Single Cable amp 5 Wire Power Cord EG1EC36A EG1EC36A4 EG1EC36A5 Because most ceilings are white all canopies ship as white unless specifically ordered otherwise standard and slot T For mounting fixtures direct one CGK per non power suspension point and one CGKP per powered suspensi Both CGK and CGKP ship with two types of clips y to the T grid order on point The CGKP will include a special canopy with flex coupler grid clips and additi onal clips to mount the junction box to the top of the grid nearby J Box Lightolier is a Philips group brand and flex conduit provided by others EGCC36 EGCC36X4 EGCC36X5 Ceiling Grid Kit Power CGKP Cable Assembly Single Cable EGC36 Job information tee 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 PHILIPS LIGHTOLIER Page 4 of 4 Lighting Systems EG1 13 Energos 3 Light T5 per 4 121 92cm Nominal Lens Performance Three Lamp Fixture With Open Top Candlepower Candlepower Curve Zone gt 0 zi
9. p Chart Below Chart Below Lens 8 8 243 84cm 2 277V W White 5 5 through wires 6 6 through wires D Dual Switch T Tandem Switch E Emergency Pack When ordering no lamps provided by Lightolier use Lamp code Z Module Ordering Specifications Lamping and Distribution 3 3 Lamp Open Top Ballast Specifications Lamping Specifications Start F Rated Output Code Lamp Type Ballast Factor Type THD Code Lamp Type Wattage Lumens Color K F 18 1 00 Program lt 10 M 15 28 2600 830 G T5HO 1 00 Program lt 10 N T5 28 2600 835 Dim T5 1 00 01 Program lt 10 0 T5 28 2600 841 J Dim T5HO 1 00 03 Program lt 10 P T5 54 4450 830 Q T5 54 4450 835 Dimming Advance Mark 10 standard no additional wires required for T8 and R T5 54 4450 841 T5HO fixtures 5 wire dimming required for T5 non HO fixtures Optional dimming 25 c Rating systems Lutron ECO 10 and Hi Lume by others require 4 wire modules and end sets Mark 7 ULT DALI and Lightolier HDF require 5 wire modules and end sets Energos can accept ballasts not to exceed 1 7 4 32cm wide by 1 2 3 05cm high Shielding L Linear Prismatic Lens Length Voltage Finish 4 4ft 48 121 92cm 1 120VAC A Aluminum 8 8ft 96 243 84cm 2 277VAC W White Wiring Options Blank Leave blank if ordering standard fixture 4 4 through wires 5 5 through wires 6 6 through wires Feature Options D Dual Switching AKA A B switching DOAA It 3
10. s Standard e 635 Lumens e 1100 Lumens e 1375 Lumens Emergency battery packs can be used for emergency egress lighting since all listed packs operate for a minimum of 90 minutes or can be used as momentary lighting for emergency circuit power transitions Smaller packs are recommended for this purpose Dimming T8 and T5HO lamps are dimmed with two wire ballasts T8 lamps can be dimmed down to 5 and T5HO lamps can be dimmed down to 1 T5 lamps require 5 wire dimming ballasts and can be dimmed down to 1 A 5 wire power feed will be required for T5 non HO dimming Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off Labels Included UL cUL and IBEW Lightolier is a Philips group brand Features 1 Housing 18 gauge steel 6 15 24cm cast aluminum end caps No exposed fasteners or hardware 2 Lamping 3 T5 fluorescent lamps per 4 121 92cm section Lamps by Lightolier as an option see ordering information 3 Reflector Precision die formed premium anti iridescent highly reflective alu minum 4 Lens Clear plastic 5 cell honeycomb lens with linear prismatic bottom surface Lens curvature matches radius of housing Mountings Cable suspension is on 48 121 92cm and 96 243 84cm centers and consists of a 4 1 2 11 43cm diameter canopy finished white enamel A 1 16 0 16cm diam eter stainl
Download Pdf Manuals
Related Search
Related Contents
KB3030 GPRS DTU User Manual Shenzhen User`s Manual - Impatica.com LSI LSI-8087-8482P-1M Serial Attached SCSI (SAS) cable Frigidaire FFBD2411NM Product Specifications Sheet General Electric Jtp30spss Installation Instructions Tecumseh AE2410Z-AA1A Performance Data Sheet Tripp Lite 1-Year Extended Warranty Copyright © All rights reserved.
Failed to retrieve file