Home
LG LDE3015SB Installation Manual
Contents
1. be connected to the middle post of the main terminal block The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block Failure to do so can result in electrical shock severe personal injury or death rae n connection plate Separate Strain Relief before installation Install the power cord as follows For power cord installations Hook the strain relief over the power cord hole 1 s located below the rear of lower oven Insert the power cord through the strain relief and tighten it Refer to Figure 7 Assemble the strain relief to the 1 s opening in Conduit connection plate DO NOT install the power cord without a strain relief FIGURE 7 1 Remove the lower 3 screws from the terminal block and retain them Refer to Figure 8 3 wire connection 2 Insert the 3 screws through each power cord Black White Red terminal ring and into the lower terminals of the 1h Terminal terminal block 5 7 Make sure that the center wire white neutral is connected to the center lower position of the terminal block 3 Tighten 3 screws securely into the terminal block Do not remove the ground strap connections 4 Go to page 10 Conduit connection plate FIGURE 8 Part 3 ELECTRICAL CONNECTIONS 4 wire connection with a power supply cord 3 wire connection conduit 4 WARNING Only
2. 1 Locate the bracket using the template An Anti tip bracket is packaged with template The instructions include necessary information to complete the installation Read and follow range installation instruction sheet template 2 Level the range Level the range by adjusting the leveling legs with a wrench 10 LG Life s Good LG Customer Information Center 1 800 243 0000 USA Consumer User 1 888 865 3026 USA Commercial User 1 888 542 2623 CANADA Register your product Online wwvw lg com Printed in Mexico
3. 76 2cm 30 76 2cm 36 Counter Minimum yp 91 4cm top height t MA f Bs Sas ay 4 15 38 1cm Wall 15 38cm ___ Center ea e es 30 j 76 2cm A 30 76 2 cm For U S A 30 76 2 cm 31 78 7 cm For CANADA FIGURE 1 FIGURE 2 MINIMUM DIMENSIONS Figure 2 30 76 2 cm minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or 24 60 9 cm minimum when bottom of wood or metal cabinet is protected by not less than 1 4 6 4 cm flame retardant millboard covered with not less than no 28 MSG sheet steel 0 015 0 381 mm stainless steel 0 024 0 610 mm aluminum or 0 020 0 508 mm copper 15 38 1 cm minimum between countertop and adjacent cabinet bottom 5 Part 3 ELECTRICAL CONNECTIONS 3 ELECTRICAL CONNECTION REQUIREMENTS This appliance must be installed and grounded on a branch circuit by a qualified technician in accordance with the National Electrical code ANSI NFPA NO 70 latest edition All wiring should conform to Local and NEC This range requires a single phase 3 wire A C 120 208V or 120 240V 60Hz electrical system Use only a 3 conductor or a 4 conductor UL listed range cord with closed loop terminals open end spade lugs with upturned ends or similar termination DO NOT install the po
4. LG Life s Good HSIMDN4A KONEKSE INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE Please read these instructions thoroughly before installing and operating the range LDE3019ST LDE3015ST LDE3017ST LDE3015SB LDE3017SB LDE3015SW LDE3017SW P No MFL63290401 www lg com Gta SAFETY 1 BEFORE YOU BEGIN Remove all tape and packing materials before using the range Dispose of all plastic bags after unpacking the range Never allow children to play with packing materials IMPORTANT SAFETY INSTRUCTIONS Read and follow all instructions before using your oven to prevent the risk of fire electric shock personal injury or damage when using the range This guide does not cover all possible conditions that may occur For further assistance contact your service agent or manufacturer A This is the safety alert symbol This symbol alerts you to potential hazards that can cause personal injury to you and others All safety messages will follow the safety alert symbol with either the word WARNING or CAUTION This symbol will alert you to hazards or unsafe practices which could cause serious A WARNING bodily harm or death This symbol will alert you to hazards or unsafe practices which could cause bodily a CAUTION injury or property damage amp WARNING The information in this manual should be followed exactly A fire or electrical shock may result causing property damage personal injury or death An
5. 501 18 500 50 13 4 13 3 3 4 Wire electrical wall Receptacle e 4 Wire receptacle 14 50R wi he NXA 3 Wire receptacle 10 50R FIGURE 3 4 CONNECT RANGE CORD 4 WARNING e You never remove the protection cover covering the rear of lower oven Failure to do so can result in serious damage to power cord The damage causes serious burns and electric shock The Rear Access cover must be removed Loosen the three screws with a screwdriver The terminal block will then be accessible Rear of lower oven ea ia pla FIGURE 4 The Cord Conduit connection plate is used for the installation of power cord or conduit For power cord install it with the connection plate as INSTALLED For conduit remove the connection plate located below the rear of the drawer body and use the conduit hole 1 instead of power cord hole 1 s Refer to Figure 5 and 6 11 8 2 8cm 13 8 z a sA 4 11 8 5 Conduit eF fole 13 8 F 3 5 cm Remove the Conduit connection plate FIGURE 5 Cord Conduit connection Strain relief Conduit Conduit Assemble the strain relief hole Strain relief Reinstall the Cord Conduit connection plate FIGURE 6 Part 3 ELECTRICAL CONNECTIONS JOEPIE A WARNING The middle neutral or ground wire of a 3 wire power cord or a 3 wire conduit has to
6. E TO INSTALL THE RANGE m 2 INSTALLATION DRAWINGS LDE Series only z OTe 4 WARNING Re SAVE FOR THE USE OF THE LOCAL e You should use two or more people to move T ELECTRICAL INSPECTOR and install range Excessive Weight Hazard Failure to do so can result in back or other injury You never pull or push any handles of upper amp lower door to move and install range Failure to do so can result in serious damage to the door of the range CLEARANCES AND DIMENSIONS Figure 1 To install range refer to the following Figure 1 For installation in CANADA a Free standing range is not to be installed closer than 15 32 12mm from any adjacent surface CAUTION 4 CAUTION You should make sure that the wall e Cabinet storage space located above covering countertop and cabinets the surface units should be avoided around the range can withstand the heat e You should install a range hood that up to 194 F generated by the range projects horizontally a minimum of 5 Discoloration delamination or melting may occur inches beyond the bottom of the cabinets This range has been designed to comply with If cabinet Storage is to be provided the maximum alowabi wood cabinet The risk of burns or fire by reaching over the temperatures of 194 F heated surface elements can be reduced I 94 eel 60 9cm mea Norma 9CM Acceptable C_ fop denih electrical outlet area 30 _y
7. a 4 conductor power supply cord kit rated 120 240 volts 50 amperes and marked for use with ranges with closed loop connectors or open end spade lugs with upturned ends shall be used The middle neutral wire of the power cord or 4 wire conduit has to be connected to the middle post of the main terminal block The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block The 4th ground wire must be connected to the frame of the range with the ground screw Failure to do so can result in electrical shock severe personal injury or death Follow the instructions under 4 CONNECT RANGE CORD on page 5 to correctly install the strain relief 1 Remove the lower 3 screws from the terminal block and retain them Refer to Figure 9 Remove the ground screw and retain it 2 Remove ground strap and discard as shown in Figure 9 Do not discard any screws 3 Insert the ground screw into the power cord ground wire terminal ring and secure it to the range frame 4 Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block Make sure that the center wire white neutral is connected to the center lower position of the terminal block Tighten 3 screws securely into the terminal block 5 Go to page 10 4 wire connection Black White Red 5 Terminal Ground strap Remove ground strap and dis
8. card Ground screw Conduit connection plate FIGURE 9 Install the conduit as follows Remove the Conduit connection plate from the rear of lower oven and rotate it as shown in Figure 5 The conduit hole 11 s must be used First prepare the conduit wires as shown in Figure 10 3 wire 4 wire 31 2 8 9 cm 3 3 1 2 5cm 0 9 em 1 3Ja 2 5cm 0 9 cm Conduit 7 connection plate 31 2 8 9 cm FIGURE 10 Second install conduit as shown in Figure 6 For conduit installations after purchasing a strain relief insert it in the conduit hole 11 s Then install the conduit through the body of strain relief and fasten the strain relief with its ring Reinstall the bracket For conduit connections If the wire in the conduit is copper it must be 8 or 10 AWG wiring If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring 1 Loosen the lower 3 screws from the terminal block Refer to Figure 11 2 Insert the bare wire white neutral end through the center terminal block opening Do not remove ground strap connections 3 Insert the two side bare wire ends into the lower left and the lower right terminal block opening Tighten the 3 screws securely into the terminal block approximately 35 50 IN LB 4 Go to page 10 3 wire connection Black White Red Terminal Conduit aaa connection plate FIGURE 11 ELECTRICAL CONNECTIONS Follow th
9. e a level to check your adjustments Place the level diagonally on the oven rack and check each direction for level 5 ANTI TIP DEVICE INSTALLATION 4 WARNING First check direction After check direction Any person should not t it d If the level doesn t show iA Step or sit on oven door level on the rack adjust the af You should install the Anti leveling legs with a wrench Tip Bracket supplied with the range CA The range could be tipped and L6 FINAL INSTALLATION injury might result from spilled hot Move range close enough to the opening to plug liquid food or the range itself into the receptacle If the range is pulled away from e Slide range into position insuring that the left back the wall for cleaning service or leg slides under the anti tip bracket Range should sit any other reason ensure that the flush against the back wall when properly installed Anti Tip Device is properly e Carefully attempt to tip range forward to insure that reengaged when the range is the anti tip bracket is engaged properly If properly pushed back against the wall installed the anti bracket will prevent the range from being tipped If the range can be tipped reinstall the range until the bracket is properly installed and the range will not tip forward Anti tip Wall plate bracket Screw m st e Turn on electrical power Check the range for proper operation as described in owner s manual
10. e instructions under Install the conduit as follows on page 7 to correctly install the strain relief DO NOT install the conduit without a strain relief Loosen the 2 lower left and right screws from the terminal block Refer to Figure 12 Remove the lower 2 center screws Remove ground strap and discard as shown in Figure 12 Do not discard any screws Attach the ground bare wire end to range frame and secure it in place with the ground screw Refer to figure 12 Insert the bare wire white neutral end through the center terminal block opening Insert the two side bare wire ends into the left and the right terminal block opening Tighten the 3 screws securely into the terminal block approximately 35 50 IN LB Go to page 10 4 wire connection Black White Red strap Remove ground strap and discard Conduit connection plate FIGURE 12 JOEPIE Part 4 INSTALL THE RANGE Replace the access cover on the back of the range To replace the wire cover insert the two tabs into the openings located below the opening and tighten the three screws h L mv ao OS I v 7 lt Access cover OC eta leveler Raise range ATIA m a om fA I oW Y A z oe m K Us
11. he installation procedure Failure to do so can result in bodily injury NOTE e Read all instructions contained in these installation instructions before installing range e Remove all packing materials from the oven compartments before connecting the electrical supply to the range e Observe all governing codes and ordinances e Be sure to leave these instructions with the consumer NOTE Keep these instructions with your owner s manual for future reference e As when using any appliance generating heat there are certain safety precautions you should follow e Be sure your range is installed and grounded properly by a qualified installer or service technician e Make sure the wall coverings around the range can withstand the heat generated by the range e To eliminate the need to reach over the surface elements cabinet storage space above the elements should be avoided PREPARE TO INSTALL THE RANGE TOOLS NEEDED Ces Phillips Screwdriver Mi Flat blade Screwdriver C 1 4 Nut Driver c a a Lae Pliers Tape Measure Safety Glasses QET Ge Pencil Gloves PARTS PROVIDED Template RBeAA aub Lag Bolts Anti Tip Bracket Kit Anchor Sleeves For Anti Tip Bracket Mounted on Concrete Floors and Walls PARTS NOT PROVIDED Strain Relief For Conduit Installations Only UL Approved 40 or 50 AMP 4 Wire Cord OR 3 Wire Cord Part 2 PREPAR
12. ve the protection cover covering the rear of lower oven Failure to do so can result in serious damage to power cord The damage causes serious burns and electric shock 4 WARNING The middle neutral or ground wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block Failure to do so can result in electrical shock severe personal injury or death Only a 4 conductor power supply cord kit rated 120 240 volts 50 amperes and marked for use with ranges with closed loop connectors or open end spade lugs with upturned ends shall be used The middle neutral wire of the power cord or 4 wire conduit has to be connected to the middle post of the main terminal block The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block The 4th ground wire must be connected to the frame of the range with the ground screw Failure to do so can result in electrical shock severe personal injury or death JOEPIE amp CAUTION e You should put on gloves during the installation procedure Failure to do so can result in bodily injury You should make sure that the wall covering countertop and cabinets around the range can withstand the heat up to 194 F generated b
13. wer cord without a strain relief A range cord rated at 40 amps with 120 240 minimum volt range is required If a 50 amp range cord is used it should be marked for use with 17 8 diameter connection openings This appliance may be connected by means of conduit or power cord If conduit is being used go to page 7 for 3 wire conduit connections or page 8 for 4 wire conduit connections A WARNING e New branch circuit installations 1996 NEC for mobile homes recreational vehicles and installations where local codes do not allow grounding through the neutral wire require a 4 conductor UL listed range cord or 4 wire conduit connection Power supply cord and plug should not be modified If it will not fit the outlet have a proper outlet Installed by a qualified electrician Using an extension cord to connect the power is prohibited The way to connect the power cord and plug directly is strongly recommended Electrical ground is required on this appliance You should make sure that the power cord is not pinched by the range or heavy objects Failure to do so can result in serious burns or electrical shock Specified power supply cord kit rating Diameter inches of Range connection Opening Conduit Range rating watts Specified rating of power supply 120 240 volts 120 208 volts cord kit amperes Power cord 3 wire 3 wire 8 750 16 500 7 801 12 500 40 or 50A 13 3 1 3 16 501 22 500 12
14. y person should not step or sit on the oven door You should install the Anti Tip Bracket supplied with the range The range could be tipped and injury might result from spilled hot liquid food or the range itself If the range is pulled away from the wall for cleaning service or any other reason ensure that the Anti Tip Device is properly reengaged when the range is pushed back against the wall e You should use two or more people to move and install range Excessive Weight Hazard Failure to do so can result in back or other injury e You never pull or push any handles of upper amp lower door to move and install range Failure to do so can result in serious damage to the door of the range e New branch circuit installations 1996 NEC for mobile homes recreational vehicles and installations where local codes do not allow grounding through the neutral wire require a 4 conductor UL listed range cord or 4 wire conduit connection e Power supply cord and plug should not be modified If it will not fit the outlet have a proper outlet Installed by a qualified electrician e Using an extension cord to connect the power is prohibited The way to connect the power cord and plug directly is strongly recommended Electrical ground is required on this appliance e You should make sure that the power cord is not pinched by the range or heavy objects Failure to do so can result in serious burns or electrical shock e You never remo
15. y the range Discoloration delamination or melting may occur This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194 F e Cabinet storage space located above the surface units should be avoided e You should install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets If cabinet Storage is to be provided The risk of burns or fire by reaching over the heated surface elements can be reduced e You should not install the range in the humid place Splashing the range with water or any electrolyte can result in electrical shock e You should not let cooking grease or flammable material accumulate in or near the range Failure to do so can result in serious burns 4 WARNING e The information in this manual should be followed exactly A fire or electrical shock may result causing property damage personal injury or death 4 WARNING Any person should not step or sit on the oven door You should install the Anti Tip Bracket supplied with the range The range could be tipped and injury might result from spilled hot liquid food or the range itself ea a If the range is pulled away from the wall for cleaning service or any other reason ensure that the Anti Tip Device is properly reengaged when the range is pushed back against the wall 4 CAUTION e You should put on gloves during t