1. 10 Close the front cover and gently slide the iCAM downwards over the back plate Fasten with two security screws on the bottom of the unit Note The iCAM includes two tamper switches One switch is located on the rear of the iCAM to detect removal from the wall or enclosure from which it is installed A second tamper switch is located behind the front plate to detect tampering with the front of the unit During installation be sure that the rear tamper switch is in a position which can detect unit removal from the wall or enclosure iICAM4000 Configuration Changing the IP Address of the iCAM Note The IP Address of each iCAM must be changed individually Do not connect more than one un configured iCAM to the network at any one time to avoid IP Address conflicts Any computer with a web browser which supports graphics ex Internet Explorer can be used to configure the iCAM4000 4100 1 Set the computer to the static IP of 192 168 5 1 subnet 255 255 255 0 2 Open the web browser and enter http 192 168 5 100 in the address bar then press ENTER The iCAM login screen will appear 3 Enter the default Username iCAM4000 and Password iris4000 both are case sensitive lrisAccess iCAM 4000 4100 Configuration E Administrator Login version 3 02 copyright 2007 LG Electresics USA Inc Iris Technology Orvisien All righas reserves 4 The iCAM Configuration Main Menu will appear lrisAccess Chan
2. 4000R e CY iCAM4010 E1 e iCAM4010R E1 d iCAM4010 H1 iCAM4010R H1 3 Installation Requirements bottom OF ghh mirror m ids rile punt x aat 61 n 56 155mm 142mm NOt TOT The recommended mounting height for the iCAM4000 is 142cm 56 inches from the floor to the bottom of the unit This mounting height can be adjusted to accommodate the height of the average user at the installed location e High amounts of ambient light must be avoided Intense light sources such as sunlight or halogen lamps may reduce the image capture performance of the iCAM this may result in an increased failure to acquire rate The iCAM is not weatherproof and must not be exposed to precipitation or extreme temperatures An enclosure may be used to protect the unit if required See www lgiris com Support amp Service for more information All system components including the Ethernet network must be powered through Uninterruptible Power Supplies UPS UPS must provide power line filtering as well as power back up operation Each IrisAccess system component on the Ethernet network system must have a unique manually assigned IP address The iCAM4000 requires at least the following wires e Ethernet network wiring to connect with the network switch to communicate to the IrisServer or an ICU Note For systems consisting of only an IrisServer and iCAM may use an Ethernet crossove
3. Input 110 240V AC 1 5AMP 50 60Hz Output 12V DC 5 0AMP e Power Cable for 110V e CAT5 Ethernet Cable e Quick Start Guide e Security Screw Wrench Required Equipment not included with iCAM4100 e Server Computer refer to the Hardware Manual for details e Ethernet Switch e Ethernet Wiring e Uninterruptible Power Supply 2 iCAM4000 in the IrisAccess System Ethernet iCAM4000 4100 i On Door Control aie ae RS 422 Serial CCCI Network switch The iCAM4000 is a two eye iris camera used to capture the iris images of the user The iCAM includes an alignment indicator behind the mirror and voice prompts to assist the user When used in a typical access control application the iCAM will be placed near the secured portal and provides the means for the system to identify the user requesting entry The iCAM can be used in enrollment mode using the IrisEnroll application included with EAC software or recognition mode when it is configured for use with an ICU The iCAM can not easily be switched between enrollment and recognition modes once configured The iCAM can be wall mounted or used with an optional desk top stand cradle iCAM4000 Model Variations Smartcard Reader Base Model RoHS compliant HID iClass IE Smart ID iCAM4000 iCAM
4. bles through the back plate hole 6 Use the appropriate fasteners for the material in which the iCAM will be mounted secure the back plate 7 Attach the wires from the 12VDC power supply to the screw terminal connections The 12VDC white wire power connects to the positive terminal whereas the 12VDC ground black wire connects to the negative terminal Note If it is required to extend the length of the wires from the power adapter to the iCAM refer to the www lgiris com support web site for details 8 Connect the CAT5 RJ45 network wire into the LAN port CN10 of the iCAM Make sure that the RJ45 connector locks securely into the LAN port oh Q General Purpose I O Power Input Reset Unused ND ve C g ae ie Sea a SE Q a3 ES Unused 838 8 3 Unused Q Tamper SW SmartCard Reader Serial RS 232 422 485 Wiegand IN Wiegand OUT 9 Wiegand device such as proximity card reader and smart card readers may be connected to the iCAM through the Smartcard or Wiegand In connections Refer to the 4000 Hardware Manual for connection details Note Only the Smartcard serial and Wiegand input interfaces are active with the current iCAM versions Note The iCAM4010 H1 and iCAM4010 E1 are supplied with a smart card reader already wired and installed
5. f changing the IP Address to multiple iCAMs Note After each iCAM configuration the arp cache on the computer must be deleted Click on Start in the Windows task bar Select Run Type cmd Press Enter At the command prompt type arp d Close the command prompt window Connect the next iCAM to be configured on the network and perform the configuration to the next iCAM PICO sent D a 3 iICAM4000 Configuration cont d Once all iCAMs have been configured Once all iCAMs have been configured the computer IP Address can then be changed back to its original IP Address or to the new IP Address as required to communicate to the rest of the IrisAccess system SmartCard Integration e The iCAM4010 E1 and iCAM4010R E1 have a built in Integrated Engineering Smart ID smart card reader and the iCAM4010 H1 and iCAM4010R H1 have a built in HID iClass smart card reader e The only configuration to the iCAM for smart card support is to enter an Air link Encryption key or Application key This key is used to lock unlock access to the smart card data Once changed the iCAM will write all cards with this key enrollment and will only be able to read cards with this key verification e To configure the smart card key log into the iCAM configuration interface see Changing the IP Address of the iCAM in section 6 e From the main menu select SmartCard Configuration lrisAccess iCAM 4000 4100 Configuration E S
6. ge Username Password Configuration Settings SmartCard Configuration Network Settings ICAM Software Update ICAM WebConfig Update Voice Message Update Reboot version 3 03 O copyright 200 LO Clectrosics USA Inc Ins Technology Owvipisa All righes reserved 7 iCAM4000 Configuration cont d 5 Select Network Settings lrisAccess iCAM 4000 4100 Configuration E Network Settings IP Address 192 168 5 100 Subnet Mask 255 2 2 0 x Ces Back to Main Enter the new IP address for the iCAM default 192 168 5 100 Enter the new Subnet Mask for the iCAM default 255 255 255 0 Enter the new Broadcast Address for the iCAM default 192 168 5 255 Enter the new Default Gateway for the iCAM default 192 168 5 254 0 Click OK to save changes and to open network settings verify screen See If the new iCAM IP address is still on the same subnet as the computer after 10 seconds the web browser will resolve to the new IP address and the login screen will appear again If the new iCAM IP Address is on a different subnet the web browser will display the standard The page cannot be displayed message To test the IP Address change perform a ping to the new IP Address Click on Start in the Windows task bar Select Run Type cmd Press Enter At the command prompt type ping lt new IP gt ex ping 192 168 5 120 Close the command prompt window OF OT NS a I
7. lrisAccess LG Advanced Identity Authentication Advanced Identity Authentication ICAM 4000 Quick Start Guide FOR MODEL NUMBERS iCAM4000 iCAM4000R iCAM4010 E1 iCAM4010R E1 lrisAccess iCAM4010 H1 inant alc fo iCAM4010R H1 COPYRIGHT 2007 LG ELECTRONICS USA INC ALL RIGHTS RESERVED LG IrisAccess 4000 iCAM4000 Quick Start Guide The content of this document is furnished for informational use only is subject to change without notice and should not be construed as a commitment by LG Electronics USA Incorporated LG Electronics USA Incorporated assumes no responsibility of liability for any errors or inaccuracies that may appear in the informational content contained in this document Please remember that existing images or drawings that you may want to include in your document may be protected under copyright law The unauthorized incorporation of such material into your work could be a violation of the rights of the copyright owner Please be sure to obtain any permission required from the copyright owner LG LG Iris the LG logo LG Iris logo and IrisAccess are either registered trademarks or trademarks of LG Electronics Incorporated in the United States and or other countries LG Electronics USA Incorporated Iris Technology Division 7 Clarke Drive Cranbury New Jersey 08512 USA Document Number DV002Q501 07 07 1 Packing List What s in the box e jCAM4000 IrisCamera e Power Adapter
8. martCard Configuration Senal Port SmartCard Type ADPICADON Key lesseseesesececes Sat to Odak exsdeamal es ox Cex Back to Main e Leave the Serial Port selection as Serial Port 2 e Select the Smart Card Type HID iClass iCAM4010 H1 MIFARE or Smart ID iCAM4010 E1 e Enter the Application Key Air Link Key in Hexadecimal format Note Set to Default will reset the Application Key to the HID iClass default e OK must be clicked for the changes to be entered e To complete the smart card integration in the IrisAccess system the lrisServer IrisEnroll software and ICUs must be configured Refer to the 4000 Smart Card Integration document located on the EAC software CD for more information 9 Technical Support Technical Support Additional information and Technical assistance is available on the LG Electronics Iris Technology Division s support web site at www giris com click on Support amp Service then Technical Support
9. r cable to connect the iCAM directly to the IrisServer computer e Power 12VDC 10 and 2 5Amps MAX IMPORTANT IT IS RECOMMENDED TO USE THE POWER ADAPTER SUPPLIED WITH THIS PRODUCT AN OVER OR UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY 4 iCAM4000 Installation 1 Remove the two security screws use included security bit wrench from the bottom of the iCAM 2 While gently pulling the cover upward on the back plate pull forward 3 Position the iCAM back plate on the desired wall near the secured door and mark the holes as the figure below illustrates The recommended height from the floor to bottom of unit is 142cm 56 however the installation height can be adjusted depending on average user height a 210 a 206 4 2 181 6 li 4 Bs i ee a i i Q t y HOLE Ln z gii HOLB HOLE t L f 2 ee ee aps py i fr 1 HOLE wN HOLE wo HOLE HOLB N t if Dimensions and Screw Holes on the Rear Enclosure 68 5 wall ae eee ai 42 9 i re oF lt E ee q E 7 t Rotation Part with Front Enclosure Rear Enclosure Dimensions of iCAM4000 mm unit ICAM4000 Installation cont d 4 When recessed mounting leave 6mm 1 4 of extra space above the marked hole so when mounting the back plate it allows the iCAM to slide down onto the installation plate tabs 5 Route the power line network line and other necessary ca