Home
KTI Networks KS-115F Series User's Manual
Contents
1. Cat 5 UTP cable 100 meters max 10 100BASE TX switch Cat 5 UTP cable 100 meters max 3 5 Operating Mode Four TP ports are designed as auto negotiation capable switched ports Each port can determine the speed and duplex type used automatically through an auto negotiation process with the remote connected auto ne gotiation device The auto negotiation process is performed when the con nection is made When connecting to a non auto negotiation device each TP port also features the capability to auto sense the connection speed The following table lists the operation mode used for the switched port when it connects to different devices The operating mode includes the connection speed and duplex type Connected Device Operation Mode Used 10BASE T hub 10Mbps half duplex 100BASE TX hub 100Mbps half duplex Auto negotiation device Auto negotiation 2 Non auto 1 half duplex device auto speed sensing 3 half duplex Non auto full duplex device Not supported 1 Non auto non auto negotiation 2 determined through auto negotiation process 3 speed is determined by auto sensing function Most of TOBASE T hubs and 100BASE TX hubs are non auto negotia tion devices and operate on half duplex mode The operating mode of the fiber port 1s determined by the setting of duplex mode selector located on rear panel The following table lists the maximum MM fiber cable length connecting t
2. perte 6 WEEP Gal ltrs seta hotte SRM Rte NUN Piber Cable S4 ee OS UU RN pae N Pacem urs des cen Network Connections vt Operating Mode dieere REOR OE RH IC HERE messed LED Indicators iie kisser n d LED Patiel seo A RR BER A RO RETRO TERRE 11 ItitefpretatiOn cocco nec ene er ee XR YN PURI RYE RA LESSER encase AR bene Pe RSS 11 16 1 Introduction Driven by recent advances in desktop computing technology today s network applications have increased in speed power and the ability to process information To meet the demands of these more powerful appli cations this affordable switch device provides significant increase in performance for your Ethernet or Fast Ethernet network This 5 port Fast Ethernet switch comes with four 10 100 TP ports and one fiber port each capable of transmitting or receiving information simultaneously at full wire speed to control and allocate the network bandwidth 1x tooo 1 2 3 4 IOO Pwr EE E 3E esse us m Link Act Front Panel C Rear Panel The key features of this switch unit are Optimized Bandwidth Combining five 10 100Mbps based Fast Ethernet switched ports the switch delivers a high network bandwidth for your Fast Ethernet network Easy Migration With IOBASE T support on each port the switch provides a non disruptive and smooth migration path from Ethernet to a Fast Ethernet network Fiber Uplink Support With 100BASE FX port the switch pro
3. Installation Guide 10 100 Fast Ethernet Switch KS 115F Series mmm P N 750 0136 001 NETWORKS DOC 000112 KS115F K 1999 KTI Networks Inc All rights reserved No part of this documen tation may be reproduced in any form or by any means or used to make any directive work such as translation or transformation without per mission from KTI Networks Inc KTI Networks Inc reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti g ktinet com WWW http www ktinet com International Fax 886 2 26983873 E mail kti ktinet com tw WWW _http Awww ktinet com tw The information contained in this document is subject to change without prior notice Copyright KTI All Rights Reserved TRADEMARKS Ethernet is a registered trademark of Xerox Corp This device complies with Class A Part 15 the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including the interference that may cause CISPRA COMPLIANCE This device complies with EMC directive ofthe European Community and meets or exceeds the follow ing t
4. LED indicators provide quick easy to read port and switch information 1 2 Specifications Port1 4 Port 5 Cables LED indicators Filtering rate Forwarding rate Filtering address RAM buffers Environment Dimensions Power Model KS 115F T KS 115F C KS 115F SA KS 115F S3 KS 115F S5 KS 115F JM KS 115F JS KS 115F VM KS 115F VS MDI X RJ 45 jacks for 10 100BASE TX connectivity One fiber connector for 1OOBASE FX connectivity 10BASE T Cat 3 4 5 UTP cable 100 meters max 100BASE TX Cat 5 UTP cable 100 meters max 100BASE FX multimode or single mode fiber cable Power status 10 100M Link Activity Duplex Collision status per port 14 880 pps for Ethernet LOBASE T 148 800 pps for Fast Ethernet IOOBASE TX 14 880 pps for Ethernet LOBASE T 148 800 pps for Fast Ethernet IOOBASE TX Multicast Broadcast Unicast address 8K MAC addresses per unit 256KB Temperature 0 C to 40 C Relative humidity 1096 to 90 non condensing 144 mmx 100mm x 26 mm WxDxH 5 67 x 3 94 x 1 02 inch 5V 1 2A minimum Models vs Fiber Specifications Connector FiberCable Max Distance ST MM 2 Km SC MM 2 Km SC SM 15 Km SC SM 30 Km SC SM 50 Km MT RJ MM 2 Km MT RJ SM 15 Km VF 45 MM 2 Km VF 45 SM 15 Km 1 Multimode fiber 2 Single Mode fiber 2 Installing the Switch 2 1 Unpacking Check to see that you have everything before you start the installation Installation guide The switch unit One AC
5. echnical standard EN 55022 Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment This device complies with CISPR Class A WARNING This is a Class A product In a domestic environment this product may cause radio inter ference in which case the user may be required to take adequate measures CE NOTICE Marking by the symbol C indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EN 55022 Limits and Methods of Measurement of Radio Interference characteristics of Information Technology Equipment EN 50082 1 Generic Immunity Standard Part 1 Domestic Commercial and Light Industry EN 60555 2 Disturbances in supply systems caused by household appliances and similar electrical equip ment Part 2 Harmonics Table of Contents Introductio cssseicesccsassstesescatscnnvencteasececasgubcdsncesenessessecadestoueesses d EeatuteSucsd ario ere nre tester A tA eM E Oca M te es 2 Specifications cec HIM ewer uta a rata heater oat 3 Installing the Switch eere neenon d U packing 1 RON iret ce vec AU et eee E Checking AC Power ES Installirig the Switch s een esce me eye ye Ee Pee OL UHR ERR Making Network Connections scssccssssssssssssssssssvescsesceseee Network Switched Ports 2 455 tete oro ONT RR DIU T IN e
6. evice Cat 5 UTP 100 meters 3 3 Fiber Cables For different fiber connections several alternative models can be selected for different fiber connections as follows Model KS 115F T KS 115F C KS 115F SA KS 115F S3 KS 115F S5 KS 115F JM KS 115F JS KS 115F VM KS 115F VS Connector ST SC SC Wavelength Cable Max Distance 1300nm 1300nm 1300nm 1300nm 1300nm 1300nm 1300nm 1300nm 1300nm 1 Multimode fiber cable 2 Single Mode fiber cable 8 The maximum distance connecting to a full duplex device MM MM SM SM SM MM SM MM SM 2 Km 2 Km 15 Km 30 Km 50 Km 2 Km 15 Km 2 Km 15 Km The recommended multimode fiber is 62 5 125um and 9 125um for single mode fiber The following figure illustrates a connection example between two SC fiber ports RX _ Fiber cable TX TX d Fiber cable RX 3 4 Network Connections The switch can support connections to the following devices e JOBASE T network cards e 10 100BASE TX network cards e 10BASE T hub ports e 100BASE TX hub ports e 10 100BASE TX dual speed hub ports e 10 100BASE TX switch ports e 100BASE FX switch ports The following figure illustrates some connection examples and also speci fies the maximum distance of each connections Fiber port Fiber cable 10BASE T hub UTP cable Cat 3 4 or 5 UTP 100 meters max 100BASE TX hub
7. o an end station using straight through UTP cable e One 100BASE FX fiber switched port This fiber port comes with one fiber connector For ST and SC connectors the contact labeled TX is used for transmission and the other one labeled RX is used for reception One duplex mode selector is located on the rear panel Either full duplex or half duplex mode can be selected factory default full duplex Setting Position Duplex Mode FDX Full duplex HDX Half duplex The following figure illustrates the front panels with different fiber connectors AX CLI Nn SC TEL O_O Oooo ST Links ENT eee LOCO e _ a be b z B POPOD M MT RJ VF 45 10 004 4 2 3 4 3 2 UTP Cable When making a connection to another device using straight through UTP cable make sure MDI X to MDI connection rule is followed The following figure illustrates the pin assignments of a straight through UTP and a crossover UTP cable is plug 2 pair straight UTP iae plug 2 2 3 8 6 6 RJ 45 plug RJ 45 plug 2 pair crossover UTP 2 3 6 It 1s suggested to use straight through UTP cables for all UTP connec tions The maximum length and UTP cable categories used for the con nections to a 1OBASE T device and 100BASE TX device are OWUN CONNECTED DEVICE UTP CABLE USED amp MAXIMUM LENGTH 10BASE T device Cat 3 4 5 UTP 100 meters 100BASE TX d
8. o different devices Connected Device Duplex Mode Distance MM cable Network card Half duplex 400m Network card Full duplex 2 Km Class hub Half duplex 160m 2 Class II hubs Half duplex 112m Switched fiber port Half duplex 400 m Switched fiber port Full duplex 2Km T0 4 LED Indicators 4 1 LED Panel The switch provides comprehensive LED indicators for diagnosing and monitoring the operation of the unit as illustrated below 104004 1 2 3 4 PWR n Link Act 4 2 Interpretation PWRLED indicates the status of the power supplied to the switch 10 100M LED indicates the connection speed between the TP port and the associated connected device Link Act LED indicates the link status with a connected device FDX Col LED indicates the duplex mode and collision occurrences The following table lists the LED states and the indications LED STATE INDICATION Power Off No power is supplied to the device Power On Power is supplied to the device 10 100 Off 10Mbps is used 10 100 On 100Mbps is used Link Act Off No active cable link Link Act On An active link is established Link Act Blink Tx Rx activities FDX Col On Full duplex is used FDX Col Off Half duplex is used FDX Col Blink Half duplex and collision occurrences
9. power adapter for the unit 2 2 Checking AC Power Before you begin the installation check the AC voltage of your area The AC power adapter which is used to supply the DC power for the unit should have the AC voltage matching the commercial power voltage in your area The specifications of the AC power adapter are e AC input power AC power voltage of your area DCoutput power 5V VDC 1 2A min e DCplugtyp e The DC power socket for the AC power adapter 1s located on the rear of the switch as shown below DC Power socket 2 3 Installing the Switch l Install the switch with the AC power adapter provided 5 PORT FAST ETHERNET SWITCH 2 Connect the power adapter cable to the switch before connecting the adapter to the AC outlet 5 PORT FAST ETHERNET SWITCH 3 Making Network Connections 3 1 Network Switched Ports There are five ports on the switch for connection to five LAN segments Each segment is an independent shared network in one collision domain TP Switched Ports 1X 4X Fiber Switched Port 1000M 4 2 3 4 KORORORORO Pwr Duplex mode selector for fiber port Four10 100BASE TX switched ports Each port consists of one RJ 45 connector and 1s used for connection to either a 1OBASE T or 100BASE TX device The RJ 45 connectors are fixed MDI X jacks which are designed with internal crossover function It allows a connection t
10. vides a connectivity to a Fast Ethernet network via fiber cable Easy Installation With the functions of auto speed sensing and auto negotiation on each port the switch supports plug and play installation which eliminates configuration problems 1 1 Features Designed for resolving congestion problems caused by bandwidth hun gry devices and bandwidth intensive applications as well as a high num ber of users the switches not only adhere to the IEEE 802 3 IOBASE T 802 3u 100BASE TX and 100BASE FX standards but also feature Four 10 100BASE TX auto negotiation switched ports and one 100BASE FX port for flexible connections to desktop PCs servers and Ethernet hubs e The 10 100BASE TX switched ports support auto speed sensing for 100Mbps or 10Mbps connection auto configuration with auto negotiation devices full duplex or half duplex operation For the fiber port the switch series support variety of fiber connec tors for different application needs The fiber connectors include ST SC MT RJ and VF 45 types for multimode and single mode fiber cables Supports duplex mode selector for the 1 OOBASE FX fiber port e Self learning for active MAC addresses Store and forward switching to ensure only good packets are forwarded Forwarding and filtering at full wire speed Supports IEEE 802 3x flow control for full duplex operation Supports back pressure flow control for half duplex operation Comprehensive
Download Pdf Manuals
Related Search
Related Contents
Colorfly CT801 Eyas Pyxus Pro User Manual/FAQ BFC-E Manuel d`utilisation - DSI Sommaire Nuvo NV-E6GMS Stereo System User Manual E-366_Supermarine WB.xlsx FOR CENTRAL WORKSHOP LittoZym® Supra Clarion Sattelite Radio User's Manual Dale Tiffany TA70112 Instructions / Assembly Copyright © All rights reserved.