Home

Kodak A-61097 User's Manual

image

Contents

1. 2 Select the desired format option 3 7 Image Address Field Widths This mode defines the Image Address field widths Refer to Description 4 Image Address Fields for a description of proper field definitions W Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 When using a Microimager 70 without the Advanced Function Module installed only the Image Address field widths for Mode 8 and Mode 9 may be defined the field widths are predefined and unalterable in Mode 1 through Mode 7 The predefined values are e Mode 1 Fixed Field 6 Field C Level 3 0 Field B Level 2 0 Field A Level 1 6 e Mode 2 Fixed Field 6 Field C Level 3 0 Field B Level 2 6 Field A Level 1 0 e Mode 3 Fixed Field 6 Field C Level 3 0 Field B Level 2 3 Field A Level 1 3 e Mode 4 Fixed Field 6 Field C Level 3 3 Field B Level 2 3 Field A Level 1 0 e Mode 5 Fixed Field 4 Field C Level 3 2 Field B Level 2 3 Field A Level 1 3 e Mode 6 Fixed Field 6 Field C Level 3 0 Field B Level 2 4 Field A Level 1 2 e Mode 7 Fixed Field 6 Field C Level 3 0 Field B Level 2 6 Field A Level 1 0 When using a Microimager with the Advanced Function Module installed Scanner 900 Scanner 923 Scanner 9500 or Scanner Mic
2. Mode Number 10 Mode Name MODE10 T Mode Configuration m Document Printer12 MODE 10 Mode Name Ftswitch Pressed Undef eiacatt stati eae 3 Lvl Index Format Ftswitch Released Undef Same Format per Level Supprs IA Display Format Ftswitch Cnf Tone O pa 5 ormat pel k 16 4233 IA Field Widths Patch Reader 1 Of t Sae Lovell 2112 Level Rules Patch Reader 2 off Print Sequence Level 2 None Batching Patch Definition Lvi 2 Print S Level 3 Auto AEC Mode Bar Code Of Hn sequence reve Duplex Film Mode Confirmation Tone NNN Previous Menu 22222 Reduction Ratio OCR Status Off Print Level 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply R Eal 5 Off Image Mgmt Code Primary DP 1 Of Print nines Off Length Monitor Secondary DP 1 Off Prin Temolaie 4 Off Skew Monitor Doc Printer 12 Off Print Template 5 Xport Check Stacker Document Sorter O Print Template 6 Off Endorser Mode Overrides No Sav Prin Tomplats 7 Not Used Film Definition F Bank Tenislats 5 Print Template 9 Save amp End Session Don t Save amp End Session Print Template 10 Previous Menu End Configuration No Print Template Previous Menu When using a Microimager 70 without the Advanced Function Module installed a limited number of items may be selected The available items are e Print Template 1 e No Print Template A 61097 May 1997 3 99 When using a Microimager 70 with the Advanced Functi
3. m Mode Configuration Bar Code Reader MODE 10 Mode Name Ftswitch Pressed Undef Bar Code Reading Status 3 Lvi Index Format Ftswitch Released Undef Bar Code Type Supprs IA Display Format Ftswitch Cnf Tone Off of Bar Code Characters 4233 IA Field Widths Patch Reader 1 Off Bar Codes per Document 2112 Level Rules Patch Reader 2 Off Distance Between Codes None Batching Patch Definition Lvl 2 Scan Direction Auto AEC Mode Bar Code Off Image Processing Duplex Film Mode Confirmation Tone NNN Partial Read Enabled 22222 Reduction Ratio OCR Status Off Min Partial Characters 1 Roll of Cassettes COIN User Channel On i Comic Film Writer Printer Control Disply DSA Patch Reading Status Patch Horizontal Location Off Image Mgmt Code Primary DP 1 Off End Fed Patch Read Status Off Length Monitor Secondary DP 1 Off Level Change via Bar Code Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Previous Menu Off Endorser Mode Overrides No Sav Not Used Film Definition F BC Paitial Read g A Off or Disabled Save amp End Session Don t Save amp End Session On or Enabled Previous Menu End Configuration Previous Menu 2 Select the desired status complete the Patch Definition items NOTE If patch reading is enabled using the DSA make certain to Patches must be at least 2 inches in length A 61097 May 1997 Patch Horizontal Location This mode defines the position of pat
4. 5 0 Date Format Delimiter 6 0 Time Format 7 0 Alarm Tone 8 0 Confirmation Tones no entry no entry 9 0 Messages p Key Definition 0 Diagnostic Message No entry Allowed are ojj ool NI ol a A Vj N 10 0 Doc Printer 12 Print Templates see next page Fixed Field Delimiter System Clock 11 0 12 0 13 0 Version Numbers AEC BARCO FDS MCP Ol PATCH DPC OCR SCSI U CAS L CAS LAPTOP User COIN Port Protocol User defined 14 0 Baud Rate Parity Bit Character Length Handshaking 15 0 Custom Check Digit Attributes Constant 1 Constant 2 Divisor Left Right LUT Status Lookup Table 16 0 Special Character Set 17 0 Save Config to PC 18 0 Load Config from PC A 61097 May 1997 Print Template Print Template Print Template ITEM LINE PRINT ITEM ITEM LINE PRINT ITEM ITEM LINE PRINT ITEM 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 vi T 7 8 8 8 9 9 9 10 10 10 11 11 11 12 12 12 Print Templa
5. Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session m MACHINE STATE Alarm Tone Low Tone High Tone Previous Menu 2 12 A 61097 May 1997 Document Printer Film Writer Messages This option defines messages that may be printed by a document printer or film writer LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Doc Printer Film Writer Msg Messages are limited to thirty eight 88 characters for Document Printer 1 and 2 and Film Writer and 12 characters for the DP12 and can include any character that can be input from a standard keyboard alphabetic numeric and special characters NOTE Alphabetic characters are automatically converted to upper case Mainframe Configuration gt MACHINE STATE Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm
6. 2 Enter a two digit program number 3 30 A 61097 May 1997 Magnification This mode defines for the KODAK IMAGELINK Digital Workstation with Zoom Lens Accessory the desired level of magnification The default value is 20 W Microimager 70 W Microimager 70 AFM LI Scanner 900 LJ Scanner 923 E Scanner Microimager 990 J Scanner 9500 1 Select Magnification A 61097 May 1997 Mode Number 10 Mode Name MODE10 m Mode Configuration H Image Management Code H MODE 10 Mode Name Ftswitch Pressed Undef rcs h Prg Number 3 Lvl Index Format Ftswitch Released Undef W irade TO INUMDE Supprs IA Display Format Ftswitch Cnf Tone O S a Definition 4233 IA Field Widths Patch Reader 1 Oi ne Mark Si ge Mark Sizes 2112 Level Rules Patch Reader 2 O Image Polarit None Batching Patch Definition Lvl 2 Duplex Eon teteion Auto AEC Mode Bar oode 7 Film Image Orientation Duplex Film Mode Confirmation Tone NNN Image Offset 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Previous Menu Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Oi Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 Ofi Xport Check Stacker Document Sorter O Off Endorser Mode Overrides No Sav Not Used Film Definition Enter Magnification 20 Save amp End Session Don t Save amp End Session Previous Menu End Configuratio
7. Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 O Patch Reader 2 O Patch Definition Lvi 2 Bar Code O Confirmation Tone NNN OCR Status Of COIN User Channel On Printer Control Disply Primary DP 1 O Secondary DP 1 O Doc Printer 12 O Document Sorter Off Mode Overrides No Sav Film Definition F Fixed Mode Auto Mode Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration 2 Select the desired AEC mode NOTE AEC mode is not available on the scanners 3 18 A 61097 May 1997 Film Mode This mode defines the orientation of documents on film Refer to Description 5 Film Modes for a description of the available film modes The default value is Duplex W Microimager 70 W Microimager 70 AFM LI Scanner 900 LJ Scanner 923 E Scanner Microimager 990 J Scanner 9500 1 Select Film Mode Mode Number 10 Mode Name MODE10 Mode Configuration AEC Status MODE 10 Mode Name Ftswitch Pressed Undef Salas Moa 3 Lvl Index Format Ftswitch Released Undef D p Mod Supprs IA Display Format Ftswitch Cnf Tone Off uo OCS 4233 IA Field Widths Patch Reader 1 Oi Previous Menu 2112 Level Rules Patch Reader 2 O None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code O Simplx Duo Duplex Duplex Film Mode Conf
8. Display Machine Accessories MACHINE STATE Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Previous Menu Mode Configuration Language English Other Language End Session NOTE Other Language should be selected only if a foreign language prom has been installed If selected indicate which foreign language prom has been installed when filling in the Installation Questionnaire 2 4 A 61097 May 1997 Measurement System This option defines the primary measurement system English uses inches as the primary unit of measure Metric uses millimetres as the primary unit of measure The default is English W Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Measurement System 2 Select the desired unit of measurement m Mainframe Configuration m MACHINE STATE Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimite
9. Ft Switch Tone Save amp End Session Previous Menu Don t Save amp End Session End Configuration Off or Disabled On or Enabled Previous Menu 2 Select the desired action NOTE A confirmation tone is issued only when the footswitch is pressed not when a footswitch is released A 61097 May 1997 3 53 Patch Reader 1 NOTE A Patch Reader accessory or Document Scanning Array must be installed Enables or disables the primary patch reader The default value is Off or Disabled WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Patch Reader 1 Mode Number 10 Mode Name MODE10 m Mode Configuration t MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone Off 4233 IA Field Widths Patch Reader 1 Off 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off te wi Off Endorser Mode Overrides No Sav Units with Pateh Reader Not Used F
10. 1 92 in 9 60 in H E L 48 77 mm 243 84 mm 2 Select the desired location within the range 1 92 to 9 6 inches or 48 75 mm to 243 84 mm by pressing the left right arrow key s to decrement increment the default value by 0 64 inch or 16 25 mm at a time A 61097 May 1997 3 71 End Fed Patch Reading Status Enables or disables end fed patch reading using the Document Scanning Array The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 E Scanner Microimager 990 Select End Fed Patch Read Status LJ Scanner 900 E Scanner 9500 Mode Number 10 mA Mode Configuration MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Bar Code Reader Undef Undef Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition QOOQZOLOQQO PRG RZ SS a ff f o Sav 7 Z0 0009 Bar Code Reading Status Bar Code Type of Bar Code Characters Bar Codes per Do
11. Bar Code Reading Status Bar Code Type of Bar Code Characters Bar Codes per Document Distance Between Codes Scan Direction Image Processing Partial Read Enabled Min Partial Characters DSA Patch Reading Status Patch Horizontal Location End Fed Patch Read Status Level Change via Bar Code Previous Menu Bar Code Reader Bar Code Status Off or Disabled On or Enabled Previous Menu 2 Select the desired status code options will be ignored NOTE If Off or Disabled is selected definitions for the remaining bar A 61097 May 1997 3 61 Bar Code Type 3 62 Identifies the type of bar code which is to be read The default value is Code 39 E Scanner 900 E Scanner 9500 LJ Microimager 70 M amp M Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Bar Code Type Mode Number 10 Mode Name MODE10 Mode Configuration a Bar Code Reader MODE 10 Mode Name Ftswitch Pressed Undef Bar Code Reading Status 3 Lvi Index Format Ftswitch Released Undef Bar Code Type Supprs IA Display Format Ftswitch Cnf Tone Off of Bar Code Characters 4233 IA Field Widths Patch Reader 1 Off Bar Codes per Document 2112 Level Rules Patch Reader 2 off Distance Between Codes None Batching Patch Definition Lvi 2 Scan Direction Auto AEC Mode Bar Code Off Image Processing Duplex Film Mode Confirmation
12. Date Format Time Format Alarm Tone DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers Custom Check Digit Mode Configuration End Session m Mainframe Configuration Display Machine Accessories Programmable Function Keys Doc Printer Film Writer Msg User COIN Port Protocol Ol Hardware Character Set Save Configuration to PC Load Configuration from PC m MACHINE STATE 3 Select Complete Configuration Please select which machine variables you wish to load from IMAGELINK to the Laptop Mode Parameters Templates Messages Complete Configuration A 61097 May 1997 2 39 Load Configuration from PC This option is used to upload a configuration file from diskette to the scanner or microfilmer WE Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 E Scanner 923 1 Select Load Configuration from PC 2 Enter a file name to upload E Scanner 900 Display Machine Accessories Machine ID Number Display Language Measurement System Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session Mainframe Configuration Pro
13. Mode Number 10 Mode Name MODE10 m Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone Off 4233 IA Field Widths Patch Reader 1 Off 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code On Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 9500 AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Film Definition NoF This window provides access to all of the mode definition parameters NOTE The following options are not available on scanners 900 923 and 3 2 A 61097 May 1997 Mode Definitions The following section lists the items on the Mode Configuration Menu that may be selected for definition Unavailable machine types are indicated by hollow boxes Mode Name This option defines the mode name LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Mode
14. Address therefore the Image Address must be defined as having a maximum of eleven 11 characters NOTE Because only one position is reserved the check digit defaults to zero when the following conditions occur e The Lookup Table is used and the check digit is greater than ten 10 e The Lookup Table is not used and the check digit is greater than nine 9 A 61097 May 1997 2 29 Custom Check Digit Definition Custom Check Digit Formula Check Digit Constant 2 Sum of IA Digits Attributes Constant 1 Divisor Parameter Current Value Attributes 46231546231 Constant 1 00 Constant 2 00 Divisor 07 Left Right Right LUT Status No Lookup Table abcdefghijk Help Previous Menu The parameters displayed in the Custom Check Digit Definition window must be defined The following section contains an explanation of each field e Constant 2 A constant value in the range 0 through 99 IA Digits The digits comprising the Image Address The Image Address may contain a fixed field as many as three level fields The Image Address cannot exceed 11 data characters when accompanied by a check digit the check digit occupies one character position Attributes These are position weights for digits in the Image Address A zero value attribute causes the associated Image Address digit to be excluded from the check digit calculation Each digit in the Image
15. Address is multiplied by its attribute and summed For example if the Image Address is 1202 14 342 12 and you wish to calculate a check digit that excludes the fixed field 1202 the attributes using Table 1 would be 00001546231 Table 1 Default Image Address Attributes C10 EVER EAR EERE NOTE The c in Table 1 refers to the character position 2 30 A 61097 May 1997 e Constant1 A constant value in the range 0 through 99 e Divisor a constant value between 0 and 99 NOTE The divisor is not used if value specified is zero 0 In addition to the parameters in the equation there are other user defined parameters which affect check digit processing e Left Right specifier also referred to as L R of Decimal Indicates the location of the check digit in relation to the decimal point in the calculation results This rule is applied to the Sum of IA Digits Attributes Constant 1 Divisor portion of the calculation If Left is specified the check digit is the digit immediately to the left of the decimal point if Right is specified the digit immediately to the right of the decimal point is the check digit For example If the calculation produces the number 123 45 and Right is the designated Left Right parameter then 4 is used The following are exceptions to the Left Right specifier rule lf Constant2 is not zero and the Left Right specifier is Left the check digit equals the difference between Const
16. Current Day Current Date Current Time Document Counter Roll Number New Transmit Sequence Attachment Count Bar Code Data Nothing Previous Menu When using a Microimager 70 without the Advanced Function Module installed a limited number of transmit items may be selected The valid items are e Full Image Address e Nothing When using a Microimager 70 with the Advanced Function Module installed Scanner 900 Scanner 923 Scanner 9500 or Scanner Microimager 990 all of the transmit items are available for selection with a maximum of seven 7 items 2 Select the item s to be transmitted 3 81 Printer Control Image Address Print Format 3 82 NOTE The Document Printer Controller must be installed W Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Printer Control E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 m Mode Configuration Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 Off Patch Reader 2 Off Patch Definition Lvl 2 Bar Code Off Confirmation Tone NNN OCR Status Off COIN User Channel On Printer Control Disply Primary DP 1 Off Secondary DP 1 Off Doc Printer 12 Off Document Sorter Off Mode Overrides No Sav Film Definition F MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rule
17. Document Sorter Mode Overrides Film Definition ss N wIRDS z AARARG aon lt nZ9999999Z79799Q99 n D lt FS Released Undetined Level 0 Level 1 Level 2 Level 3 Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration 2 Select the desired action 3 52 A 61097 May 1997 Footswitch Confirmation Tone NOTE The Footswitch accessory must be installed This mode enables or disables the footswitch press confirmation tone The default is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Ftswitch Cnf Tone E Scanner Microimager 990 E Scanner 900 E Scanner 9500 3 Lvl Supprs 4233 2112 None Auto Duplex Mode Number 10 m Mode Configuration MODE 10 Mode Name Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Name MODE10 Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef lt N NN sply o Sav 71 Z0 00090 OQz CFOO0O
18. Previous Menu End Configuration Previous Menu 2 Select the desired status NOTE If the Bar Detected Tone is enabled the Bar Code Patch Tone cannot be enabled However the Patch Detected Tone may be enabled A 61097 May 1997 Bar Code Patch Tone NOTE Patch reading and Bar Code reading must be enabled In addition the confirmation tones must have been enabled during machine definitions otherwise this definition will be ignored Enables or disables a confirmation tone issued when a bar code and a patch are both recognized The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM LJ Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Bar Code Patch Tone Mode Number 10 Mode Name MODE10 Mode Configuration Confirmation Tone MODE 10 Mode Name Ftswitch Pressed Undef Patch Detected Tone 3 Lvi Index Format Ftswitch Released Undef Bar Detected Tone Supprs IA Display Format Ftswitch Cnf Tone Off Bar Code Patch Tone 4233 IA Field Widths Patch Reader 1 Off Previous Menu 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc
19. Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F j BC Patch Tone m Off or Disabled Save amp End Session Don t Save amp End Session On or Enabled Previous Menu End Configuration Previous Menu 2 Select the desired status NOTE If either the Patch Detected Tone or Bar Detected Tone is enabled the Bar Code Patch Tone cannot be enabled A 61097 May 1997 3 77 OCR Status NOTE The OCR accessory must be installed Enables or disables Optical Character Recognition The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 J Scanner 9500 1 Select OCR Status Mode Number 10 Mode Name MODE10 Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone Oi 4233 IA Field Widths Patch Reader 1 O 2112 Level Rules Patch Reader 2 Ofi None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 Of Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Oi Off Endorser Mode Overrides No Sav Not Use
20. Stop and Display Select any of the Sort Criteria and the following screen appears Mode Number 10 m Mode Configuration Mode Name MODE10 Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef lt N NN sply oooo0ogyoo ozorToo0g Q o Sav W MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session Previous Menu Don t Save amp End Session End Configuration Default Hopper Lower Hopper Upper Hopper Previous Menu Hopper Selection A 61097 May 1997 3 101 Mode Overrides If 4 selections have been set and you choose a 5th option the following screen appears Mode Number 10 Mode Name MODE10 m Mode Configuration ERROR MODE 10 Mode Name Ftswitch Pressed Undef a Hae Deea Taa S 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cn
21. with additional documents filmed on the adjacent side A 40 1 or 50 1 reduction ratio is used for this format Lead End Trad Erd Code Code fA De C al Fi Duo yn bol fon contd pana display 4 E E D E F 5 E tama Duo 3 20 A 61097 May 1997 Reduction Ratio This mode defines the level of magnification The default value is Don t Care 1 L Scanner 923 Select Reduction Ratio L Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 J Scanner 900 LJ Scanner 950 0 Mode Number 10 3 Lvl Supprs 4233 2112 None Auto Mode Con MODE 10 Mode Name Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used figuration Mode Name MODE1O Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef 1 Reduction Ratio Don t Care 24x 40x 50x Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration Select the desired reduction ratio Use the following informa
22. 9500 Image Marker and Film Writing are not available On a machine with DSA Patch Head 2 N A Front DSA 990 923 IL70 Rear DSA 990 D Only 2 2 A 61097 May 1997 Machine ID Number E Scanner 923 Select Machine ID Number 2 Enter a number from 00 99 WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner Microimager 990 This option establishes a unique identification number for each unit in a multiple unit installation The default is 00 E Scanner 9500 Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg 5 DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session Mainframe Configuration gt MACHINE STATE Enter machine id below 00 To Change Enter Value To Retain Press Enter A 61097 May 1997 2 3 Display Language This option defines the primary display language The default is English W Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Display Language 2 Select the desired language option m Mainframe Configuration
23. Address will be printed the Fixed Field will not be printed If an option which indicates Full IA is chosen the Fixed Field and level fields of the Image Address will be printed NOTE If Customer IA Only or Customer Full IA is chosen the Check Digit options must be defined If Message Number is selected the following window is displayed A Message Number Current Print Sequence Display Values Message Number 1 Message Number 2 Message Number 3 Message Number 4 Message Number 5 Message Number 6 Message Number 7 Message Number 8 New Print Sequence Display Values Message Number 9 Previous Menu 1 Select the desired message number 3 88 A 61097 May 1997 If different information is to be printed on documents of different levels 1 Select Print Sequence Level for the desired level Print Items 3 Current Print Sequence Display Values Full A w No Delimiters Full IA w FF Delimiter Full IA w All Delimiter Fixed Field Only Indexed Fields Only Current Field Level Spaces between Items Current Day Current Date Current Time Document Counter Roll Number Message 1 9 Check Digit Nothing Printed Previous Menu New Print Sequence Display Values When using a Microimager 70 without the Advanced Function Module installed a limited number of items may be selected The availabl
24. Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav m Eon Chk Eror Response Not Used Film Definition F Display Display and Beep Stop and Display Save amp End Session Don t Save amp End Session Previous Menu Previous Menu End Configuration 2 Select the desired error response action A 61097 May 1997 Skew Monitor Skew Detect Status W Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 E Scanner 900 E Scanner 9500 NOTE The Advanced Document Controller must be installed 1 Select Skew Monitor Mode Number 10 m Mode Configuration Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 O Patch Reader 2 O Patch Definition Lvi 2 Bar Code Confirmation Tone NNN OCR Status Of COIN User Channel On Printer Control Disply Primary DP 1 O Secondary DP 1 O Doc Printer 12 O Document Sorter Off Mode Overrides No Sav Film Definition F Skew Monitor Skew Detect Status Skew Threshold Skew Error Response Previous Menu MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgm
25. Control Disply P Key y Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Previous Menu Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Of Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 2 Select the desired action NOTE When Footswitch Pressedis set to undefined F S Released cannot be set A 61097 May 1997 3 51 Footswitch Released NOTE The Footswitch accessory must be installed This mode defines the action which results when the footswitch is pressed The default is Undefined WE Microimager 70 W Microimager 70 AFM E Scanner 923 1 E Scanner Microimager 990 Select Ftswitch Pressed E Scanner 900 E Scanner 9500 Mode Number 10 Mode Configuration t MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone ff Patch Reader 1 ff Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12
26. DP 1 O End Fed Patch Read Status Off Length Monitor Secondary DP 1 Ofi Level Change via Bar Code Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter O Previous Menu Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration A 61097 May 1997 Bar Code Reading Status E Scanner 923 LJ Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 Select Bar Code Reading Status Enables or disables bar code reading The default value is Off or Disabled E Scanner 900 E Scanner 9500 Mode Number 10 mA Mode Configuration MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch Reader 1 Ofi Patch Reader 2 O Patch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status Off COIN User Channel On Printer Control Disply Primary DP 1 Of Secondary DP 1 O Doc Printer 12 O Document Sorter O Mode Overrides No Sav Film Definition Save amp End Session Previous Menu Don t Save amp End Session End Configuration
27. Document Printer 12 in the transport plate 2 20 A 61097 May 1997 Fixed Field Delimiter A 61097 May 1997 This option defines the fixed field delimiter used in the Image Address Display The default is a Period NOTE The Fixed Field Delimiter doesn t appear on the display it appears when printing the Image Address LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Fixed Field Delimiter 2 Select the desired Fixed Field delimiter NOTE In order to print the Fixed Field Delimiter using Document Printer 12 the Image Address must be defined as having eleven 11 digits maximum m Mainframe Configuration m MACHINE STATE Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol m Fixed Field Delimiter Custom Check Digit Slash Ol Hardware Character Set Save Configuration to PC Dash C Period Load Configuration from PC Si s pace Mode Configuration Back Slash Previous Menu End Session 2 21 Set System Clock This option sets the system clock WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 1 Sele
28. FF Update Fixed Field Previous Menu 13 Select Previous Menu to close the User COIN Port Config window 2 28 A 61097 May 1997 Custom Check Digit This option determines the check digit algorithm to be used when a custom check digit is calculated NOTE If a standard check digit algorithm is desired specify the desired algorithm during Image Address print definitions within each mode setup LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Custom Check Digit m Mainframe Configuration 4 Display Machine Accessories MACHINE STATE Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session The check digit is used to ensure the integrity of the Image Address All parameters in the algorithm are user definable offering a high degree of flexibility During filming and or scanning the microfilmer or scanner assigns each document an Image Address The Image Address is used to compute the check digit The check digit then becomes the rightmost digit of the Image
29. Field B is defined as having a field length greater than zero 1 9 Field C is defined as having a field length of zero 0 Fixed Field may be defined if desired 0 9 e Two Level Offset Field A is defined as having a field length of zero 0 Field B is defined as having a field length greater than zero 1 9 Field C is defined as having a field length of zero 0 Fixed Field may be defined if desired 0 9 e Three Level Field A is defined as having a field length greater than zero 1 9 Field B is defined as having a field length greater than zero 1 9 Field C is defined as having a field length greater than zero 1 9 Fixed Field may be defined if desired 0 9 e Three Level Offset Field A is defined as having a field length greater than zero 1 9 Field B is defined as having a field length greater than zero 1 9 Field C is defined as having a field length greater than zero 1 9 Fixed Field may be defined if desired 0 9 A 61097 May 1997 3 11 Level Rules This mode defines the level of a document based upon the level of the previous document These definitions are used as defaults when the document level is not determined by another method i e Footswitch P Key Level Key etc W Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 When using a Microimager 70 without the Advanced Function Module installed only the leve
30. Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Configuration MODE 10 Mode Name Mode Name MODE10 Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef No Sav F Document Printer 12 Document Printer Status Fonts Orientation Same Format per Level Print Sequence Level 0 Print Sequence Level 1 Print Sequence Level 2 Print Sequence Level 3 Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration 3 96 A 61097 May 1997 Document Printer Status DP12 Enables or disables the Document Printer 12 The default value is Off or Disabled W Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Document Printer Status E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 3 Lvl Supprs 4233 2112 None Auto Duplex Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorse
31. Format Same Sequence per Level Print Sequence Level 0 Print Sequence Level 1 Print Sequence Level 2 Print Sequence Level 3 NOTE This selection is not available on the scanners A 61097 May 1997 3 23 Character Orientation This mode defines the orientation of the information printed by the film writer The default is Comic E Microimager 70 W Microimager 70 AFM LI Scanner 900 LJ Scanner 923 E Scanner Microimager 990 J Scanner 9500 1 Select Character Orientation Mode Number 10 Mode Name MODE10 Mode Configuration Advanced Film Writer MODE 10 Mode Name Ftswitch Pressed Undef lol EAM ae 3 Lvl Index Format Ftswitch Released Undef S B S fi r Level Supprs IA Display Format Ftswitch Cnf Tone Off ae ss co Ta 0 4233 IA Field Widths Patch Reader 1 O Bint Seene ciev quence Level 2112 Level Rules Patch Reader 2 O Print S neet Level None Batching Patch Definition Lvi 2 Pnt Soio anei S Auto AEC Mode Bar Code O q Duplex Film Mode Confirmation Tone NNN Previous Menu 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Orientation Off Endorser Mode Overrides No Sav Comi Not Used Film Definition F omie Cine Comic 180 Save amp End Sessio
32. If the definition exceeds the thirty eight 38 character limit the first thirty eight 38 characters will be printed on film next to each document and the remainder of the information will be truncated 3 27 Image Management Code NOTE The Film Writing Module must be installed E Microimager 70 W Microimager 70 AFM LI Scanner 900 LJ Scanner 923 E Scanner Microimager 990 J Scanner 9500 1 Select Image Mgmt Code Mode Number 10 Mode Name MODE10 mA Mode Configuration Image Management Code MODE 10 Mode Name Ftswitch Pressed Undef een Pro Number 3 Lvi Index Format Ftswitch Released Undef Magnificat g Supprs IA Display Format Ftswitch Cnf Tone Off S e Definition 4233 IA Field Widths Patch Reader 1 Off image Mark Sizes 2112 Level Rules Patch Reader 2 Off Image Polarit None Batching Patch Definition Lvl 2 Da ae Ereni T Auto AEC Mode Bar Code off Pi im ga O entation Duplex Film Mode Confirmation Tone NNN Image Offset 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Previous Menu Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration NOTE This selection is not av
33. Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session m MACHINE STATE c User COIN Port Config Baud Rate 9600 Parity Bit None Char Length 8 Bits Handshaking None Update FF Update Previous Menu Char Length 7 Bits 8 Bits Previous Menu A 61097 May 1997 2 27 9 Select Handshaking 10 Select the handshaking protocol Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session gt MACHINE STATE Baud Rate Parity Bit Fa User COIN Port Config Char Length 8 Bits Handshaking None 9600 None Update FF Update Previous Menu Handshaking None CTS RTS Previous Menu 11 Select Update F F 12 Select Fixed Field option Update Fixed Field Don t Update
34. Name Mode Number 10 Mode Name MODE10 Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone O 4233 IA Field Widths Patch Reader 1 Off 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Oi 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Ofi Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Enter Mode Name MODE10 Save amp End Session Don t Save amp End Session Previous Menu End Configuration 2 Enter a ten 10 character maximum alphanumeric name A 61097 May 1997 3 3 Index Format This mode defines the index format used by the application mode Refer to Description 3 Index Formats for a description of the index formats W Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 When using a Microimager 70 without the Advanced Function Module installed only the index format for Mode 8 and Mode 9 may be defined the index format is predefined and unalterable in Mode 1 through Mode 7 The predefined values
35. Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session m Mainframe Configuration MACHINE STATE Instructions 1 Check the character display on the bottom line of the Ol 2 Select the character set based on the character Chracter Set Anglo Japanese Anglo European Printer Font Anglo Japanese Anglo European Previous Menu A 61097 May 1997 Save Configuration to PC This option is used to download a configuration file from the scanner or microfilmer onto diskette This is useful in creating configuration files which may be transported to other units see the Load Config from PC option This is also used to create backup files This option should be performed any time an installation or setup change is completed W Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 E Scanner 923 1 Select Save Configuration to PC 2 Enter a file name up to 8 characters long no special characters allowed E Scanner 900 E Scanner 9500 Machine ID Number Display Language Measurement System
36. Of Of Of No Sav F 1 Cassettes Req d Two Cassettes One Cassette Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration 2 Select the minimum number of cassettes required NOTE This selection is not available on the scanners 3 22 A 61097 May 1997 Film Writer NOTE The Film Writing Module must be installed W Microimager 70 W Microimager 70 AFM LJ Scanner 923 1 Select Film Writer E Scanner Microimager 990 LJ Scanner 900 LJ Scanner 9500 Mode Number 10 3 Lvl Supprs 4233 2112 None Auto Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Configuration MODE 10 Mode Name Mode Name MODE10 Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef M Z0OQ00000 Save amp End Session Previous Menu Don t Save amp End Session End Configuration Previous Menu Advanced Film Writer Character Urientation Image Addr Print
37. On Printer Control Disply Primary DP 1 O Secondary DP 1 Of Doc Printer 12 O Document Sorter Of Mode Overrides No Sav Film Definition F Bar Code Reading Status Bar Code Type of Bar Code Characters Bar Codes per Document Distance Between Codes Scan Direction Image Processing Partial Read Enabled Min Partial Characters DSA Patch Reading Status Patch Horizontal Location End Fed Patch Read Status Level Change via Bar Code Previous Menu Image Process Save amp End Session Previous Menu Don t Save amp End Session End Configuration Off or Disabled On or Enabled Previous Menu 2 Select the desired image processing status 3 67 Partial Read Enabled 3 68 Enables or disables partial bar code reading The default value is Off or Disabled E Scanner 900 E Scanner Microimager 990 W Scanner 9500 LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Partial Read Enabled Mode Number 10 Mode Name MODE10 Mode Configuration Bar Code Reader E MODE 10 Mode Name Ftswitch Pressed Undef Bar Code Reading Status 3 Lvi Index Format Ftswitch Released Undef Bar Code Type Supprs IA Display Format Ftswitch Cnf Tone Off of Bar Code Characters 4233 IA Field Widths Patch Reader 1 Off Bar Codes per Document 2112 Level Rules Patch Reader 2 Off Distance Between Codes None Batching Patch Definition Lvi 2
38. Previous Menu 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply 7 ee Off Image Mgmt Code Primary DP 1 Off on Off Length Monitor Secondary DP 1 Off S Si y t Gin Off Skew Monitor Doc Printer 12 Off man none Xport Check Stacker Document Sorter Off Small Font Comic 180 Off Endorser Mode Overrides No Sav Small rant Gine 189 P arge Font Comic Not Used Film Definition F Large Font Cine Large Font Comic 180 Save amp End Session Don t Save amp End Session Large Font Cine 180 Previous Menu End Configuration Previous Menu 2 Select the desired size and font four orientations DINOS Cc 2 N E O O ZW oo 3 86 A 61097 May 1997 Print Definitions This mode defines the information printed on each document based upon the document level The default values are Nothing Printed for Level 0 documents Full Image Address with all delimiters for Level 1 Level 2 and Level 3 documents lt FF IA All Del gt WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 MH Scanner 9500 If the same information is to be printed on documents of all levels 1 Select Same Format per Level Print Items a Current Print Sequence Display Values Full IA w No Delimiters Full IA w FF Delimiter Full IA w All Delimiter Fixed Field Only ndexed Fields Only Current Field Level Spaces between Item
39. Primary DP 1 O Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Oi Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 2 Select the desired option NOTE This selection is not available on the scanners A 61097 May 1997 Patch Recognition This mode defines which patch codes will be recognized by the system The default value is 2 3 amp T LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Patch Recognition Mode Number 10 Mode Name MODE10 m Mode Configuration Patch Definition MODE 10 Mode Name Ftswitch Pressed Undef Transfer Patch Definition 3 Lvi Index Format Ftswitch Released Undef Film Transfer Patches Supprs IA Display Format Ftswitch Cnf Tone 0 Patch Recognition 4233 IA Field Widths Patch Reader 1 ie Previous Menu 2112 Level Rules Patch Reader 2 Of None Batching Patch Definition Lvl 2 Patch R iti Auto AEC Mode Bar Code O a a 8 Duplex Film Mode Confirmation Tone NNN Type 2 Patches 22222 Reduction Ratio OCR Status Off Type 3 Patches 1 Roll of Cassettes COIN User Channel On Transfer Patches Comic Film Writer Printer Control Disply Type 2 amp Type 3 Patches Off Image Mgmt Code Primary DP 1 O Type 2 amp
40. Printer Control Disply Primary DP 1 Off Secondary DP 1 O Doc Printer 12 Ofi Document Sorter Off Mode Overrides No Sav Film Definition F Document Printer Status Fonts Orientation Same Format per Level Print Sequence Level 0 Print Sequence Level 1 Print Sequence Level 2 Print Sequence Level 3 Previous Menu DP 1 Font Selection Save amp End Session Previous Menu Don t Save amp End Session End Configuration Small Font Comic Small Font Cine Small Font Comic 180 Small Font Cine 180 Large Font Comic Large Font Cine Large Font Comic 180 Large Font Cine 180 Previous Menu DINOS C N 80 COMIC1 O ZW o0oo0o Select the desired size and font four orientations 3 92 A 61097 May 1997 Print Definitions DP2 This mode defines the information printed on each document based upon the document level The default values are Nothing Printed for Level 0 documents Full Image Address with all delimiters for Level 1 Level 2 and Level 3 documents LJ Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 E Scanner 900 E Scanner 9500 If the same information is to be printed on documents of all levels 1 Select Same Format per Level Current Print Sequence Display Values New Print Sequence Display Values Print Items Ful
41. Reader 1 Oi Patch Reader 2 O Patch Definition Lvl 2 Bar Code Oi Confirmation Tone NNN OCR Status Of COIN User Channel On Printer Control Disply Primary DP 1 Oi Secondary DP 1 O Doc Printer 12 Ofi Document Sorter O Mode Overrides No Sav Film Definition F Level 0 Level 1 Level 2 Level 3 Previous Menu MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session Previous Menu Don t Save amp End Session End Configuration 2 Select the level to be assigned a following level Mode Number 10 Mode Configuration Mode Name MODE10 Field F Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 Off Patch Reader 2 Off Patch Definition Lvl 2 Bar Code Off Confirmation Tone NNN OCR Status Off COIN User Channel On Printer Control Disply Primary DP 1 Off Secondary DP 1 Off Doc Printer 12 Off Document Sorter Off Mode Overrides No Sav Film Definition F Level 0 Level 1 Level 2 Level 3 Previous Menu Follow Field MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field W
42. Recommended Entries Accessory Status PRES Present NOTPRES Not Present Machine ID Number 00 99 Display Language ENG English FREN French GERM German ITAL Italian SPAN Spanish ENG English MET Metric Enter function s ae Function ae Time Format 12 hr AM PM 12 hr 24 hr Alarm Tone High Low Confirmation Tones ON Enabled BE Disabled Messages Enter messages Doc Printer 12 Enter line y and Print Templates print item s Fixed Field Delimiter Slash nau Period Space Backslash TERM Terminal time eae re Manual Version Numbers Numbers Enter version numbers eel Clock Date Format mmddyy mmdd ddmmmyy ddmmm mmyy yddd yyddd yymmdd ddmmyy mmmddyyyy Date Delimiter Slash Dash Period Space No Del A 61097 May 1997 User COIN Port NO Not used Protocol YES Used Baud rate 19 2 K Parity Bit NONE No parity ODD Odd parity EVEN Even parity Character Length 7 7 Bits 8 8 Bits Handshaking None CTS RTS Custom Check NO Not used Digit YES Used Attributes 11 digit string Constant 1 2 digit number Constant 2 2 digit number Divisor 2 digit number Left Right LEFT Left of decimal RIGHT Right of decimal LUT Status NO not used YES used eee Table 11 digit string JAP Japanese EURO ae 20 0 Index Format 1 Single level 2 Two level 2Off Two level offset 3 Three level 3Off
43. Scan Direction Auto AEC Mode Bar Code Off Image Processing Duplex Film Mode Confirmation Tone NNN Partial Read Enabled 2222 Reduction Ratio OCR Status Off Min Partial Characters 1 Roll of Cassettes COIN User Channel On DSA Patch Reading Status Comic Film Writer Printer Control Disply Patch Horizontal Location Off Image Mgmt Code Primary DP 1 Off End Fed Patch Read Status Off Length Monitor Secondary DP 1 Off Level Change via Bar Code Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter off Previous Menu Off Endorser Mode Overrides No Sav Not Used Film Definition F BC Partial Read Off or Disabled Save amp End Session Don t Save amp End Session On or Enabled Previous Menu End Configuration Previous Menu 2 Select the desired status A 61097 May 1997 Minimum Partial Characters A 61097 May 1997 NOTE Partial Reading must be enabled or this definition will be ignored This mode defines the minimum number of characters which must be properly decoded to constitute a partial read The default value is 5 80 LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Min Partial Characters E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Bar Code Reader Bar Code Reading Status Bar Code Type of Bar Code Characters Bar Codes per Document Distance Between Codes Scan Direction mage Processing Partial Read Enable
44. Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session m Mainframe Configuration m MACHINE STATE Using the Mode Setup Software value e If asked to select an option This section provides guidelines and conventions that will assist you in using the Mode Setup Software e There are two levels of definitions Machine definitions which apply to all modes and Mode definitions which apply to one mode e Each defined option requires you to select a displayed option or enter a Use the arrow keys to position the highlight cursor over the desired option Press the Return Enter key e f asked to enter a value Typically the highlight cursor will appear over the input field if it does not use the arrow keys to position the highlight cursor over the input field Enter type the desired value using the keyboard or numeric keypad Press the Return Enter key A 61097 May 1997 1 7 e Each window should contain an option entitled Previous Menu Typically you are returned to the previous menu after completing a definition If you are not returned to the previous menu after completing a definition or you want to return without altering the default or previously defined value select the Previous Menu option Use the arrow keys to p
45. each P Key you wish to re program A 61097 May 1997 Date Format This option defines the date display format both the date format and delimiter Refer to Description 1 Date Format Samples for a description of the available formats The default is mmddyy The default delimiter is a slash LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Date Format 2 Select a date format 3 Select a date delimiter Mainframe Configuration F m MACHINE STATE Display Machine Accessories Machine ID Number Display Language m Date Format Example Measurement System dd 12 25 92 Programmable Function Keys mmgEyy Date Format mmdd 12 25 Time Format ddmmmyy 25 DEC 92 Alarm Tone ddmmm 25 DEC Doc Printer Film Writer Msg mmyy 12 92 DP 12 Print Template yddd 2 359 Fixed Field Delimiter yyddd 92 359 Set System Clock yymmdd 92 12 25 Version Numbers ddmmyy 25 12 92 dd DEC 25 1992 User COIN Port Protocol mmmadyyyy a Custom Check Digit Date Delimiter Ol Hardware Character Set Slash mm 01 12 Save Configuration to PC Dash mmm JAN FEB Load Configuration from PC Period dd 01 31 Mode Configuration Space ddd 001 366 F No Delimiter y 0 9 End Session yy 00 99 Previous Menu yyyy 1990 2000 A 61097 May 1997 2 9 Description 1 Date Format Samples Ee
46. installed in the machine and is for viewing only no selections or entries are made E Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Version Numbers E Scanner 900 E Scanner 9500 m Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session m MACHINE STATE Version H AEC 03 36 BARCO 04 05 FDS 07 02 MCP 08 08 Ol 07 01 PATCH 02 11 DPC 07 04 OCR 00 00 SCSI 08 06 U CAS 01 00 L CAS 00 00 LAPTOP 02 35 2 Press Return Enter to close the Version window NOTE The following options are not available on scanners 900 923 and 9500 AEC n a FDS n a UCAS n a L CAS n a NOTE On the Microimager 70 SCSI n a OCR n a NOTE On the Microimager 70 AFM SCSI n a 2 24 A 61097 May 1997 User COIN Port Protocol This option enables or disables the user COIN port for communication protocols associated with OCR data Document Scanning Array Bar Code Reader or Customer specified The default val
47. of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Of Off Endorser Mode Overrides No Sav Not Used Film Definition Save amp End Session Don t Save amp End Session Previous Menu End Configuration Primary Status Off or Disabled On or Enabled Previous Menu 2 Select the desired status A 61097 May 1997 3 85 Fonts Orientation This mode defines the size and orientation of the characters printed by the primary Document Printer 1 The default value is Off or Disabled E Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 E Scanner 900 E Scanner 9500 1 Select Fonts Orientation Mode Number 10 Mode Name MODE10 Mode Configuration Primary Document Printer MODE 10 Mode Name Ftswitch Pressed Undef Document Printer statis Fonts Orientation 3 Lvl Index Format Ftswitch Released Undef 4 i Same Format per Level Supprs IA Display Format Ftswitch Cnf Tone Off Print Sequence Level 0 4233 IA Field Widths Patch Reader 1 Off Print S tevali 2112 Level Rules Patch Reader 2 Off Brini EER E None Batching Patch Definition Lvi 2 Enn Sccueneen Eeva S Auto AEC Mode Bar Code off a Duplex Film Mode Confirmation Tone NNN
48. of ink jets will be used to print each character All Document Printers On Off off disable Allows you to turn all document printers primary on enable DP1 secondary DP1 and DP12 on or off t May be executed while transport is running Available when filming for use only with Microimager 70 with or without AFM and Scanner Microimager 990 Available when scanning for use only with the Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 Available when using advanced capabilities for use only with the Microimager 70 with AFM Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 A 61097 May 1997 B 3 P Key Definition Input Code Function Code Name Description Required Optional Primary DP1 On Off 41 0 off disable Allows you to turn the primary document printer 1 on 1 on enable or off F42 Secondary DP1 On Off 0 off disable Allows you to turn the secondary document printer 1 1 on enable R NM on or off Document Printer 12 On Off Allows you to turn the document printer 12 on or off F44t Omit Printing on Next Document Only 0 off disable 1 on enable 1 Allows you to omit printing by all document printers on the next document only Print Test Allows you to test the position and print quality of all document printers installed Print Position Allows you to specify how far from the leading edge of the document all document printers will print P
49. the Microimager 70 with AFM Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 B 4 A 61097 May 1997 P Key Definition Input Code Function Code Name Description Optional Endorser Print Position Allows you to specify how far from the leading edge of the document the endorsement will appear F60 Bar Code Reading 1 On Off 0 off disable Allows you to turn bar code reading on or off 1 on enable F62 Bar Code Patch Reading Confirmation Tone Allows you to turn the bar code patch reading off disable on enable confirmation tone on or off F63 Bar Code Reading Confirmation Tone Allows you to turn the bar code reading confirmation tone on or off F64t Omit Bar Code Reading on Next Document Only Allows you to omit bar code reading on the next document only F65 Bar Code Test Allows you to perform a test to verify the operation of the bar code reader off disable on enable F70 Length Checking On Off Allows you to turn length checking on or off off disable on enable 0 off disable v1 on enable O0 off disable on enable Omit Length Checking On Next Document Only Allows you to omit length checking on the next document only F72 Skew Detection Allows you to turn skew detection on or off Latched Scanning Flag Allows you to set a flag which alerts the host system that the document and those which follow are of special interest The flag will remain activated fo
50. to Select New Directory 6 Enter an N to abort and designate a different directory Enter a Y to continue replacing the files within the designated directory A 61097 May 1997 1 3 During the installation procedure the following window will appear if you don t have the files and buffers set correctly in the config sys file Mode Setup Software INSTALLING Please Wait While Files Are Being Copied ToYour Destination Drive The CONFIG SYS File Needs To Be Checked To Make Sure That BUFFERS 40 FILES 40 Next the following windows will appear Mode Setup Software INSTALLING Please Wait While Files Are Being Copied To Your Destination Drive Mode Setup Software INSTALLING Please Wait Copying File setup zip 1 4 A 61097 May 1997 REGISTRATION Please enter the name of the registered user below Please Wait While Files Are Being Copied To Your Destination Drive _ FILECOPY COMPLETE 7 Type in user name Press Return Enter Type setup in c setup directory to start Mode Setup 8 Press any key to return to DOS 9 Eject the Mode Setup Software diskette 10 Type cd setup The SETUP directory is displayed 11 Type setup This starts the program A 61097 May 1997 1 5 Logon Procedure After the installation procedure has been perfo
51. 1 1 32 0 33 0 34 0 35 0 36 0 37 0 38 0 39 0 40 0 41 0 42 0 43 0 MODE 1 Length Monitor 31 1 Status 31 2 Max Doc Length 31 3 Min Doc Length 31 4 Error Response Skew Monitor 32 1 Status 32 2 Threshold 32 3 Error Response Check Stacker Endorser 34 1 Status 34 2 Mode 34 3 Print Position Footswitch Pressed Footswitch Released Footswitch Confirmation Tone Patch Reader 1 Patch Reader 2 Patch Definition 40 1 Xfer Patch Def 40 2 Film Xfer Patch 40 3 ___ Patch Recognition Bar Code 41 1 Status 41 2 Bar Code Type 41 3 of Characters 41 4 Codes per Doc 41 5 Distance Between 41 6 Scan Direction 41 7 Image Processing 41 8 Partial Read 41 9 Min Partial Char 41 10_ Patch Reading 41 11 Patch Location 41 12 End Fed Patch 41 13 Level Change Confirmation Tones 42 1 Patch Detected 42 2 Bar Detected 42 3 Bar Code Patch OCR Status A 61097 May 1997 Mode Definitions 44 0 COIN User Channel 44 1 Transmit Data Level 0 Level 1 Level 2 Level 3 45 0 Printer Control 45 1 IA Print Format 45 2 Print Position 45 3 Special Char Set 46 0 Primary Document Printer 1 46 1 Status 46 2 Font Orientation 46 3 Print Definitions Level 0 Level 1 Level 2 Level 3 47 0 Secondary Document Printer 1 47 1 Status 47 2 Font Orientation 47 3 Print Definitions Level 0 Level 1 Level 2 Level 3 48 0 Document Printer 12 48 1 Status 48 2 Font Orientation 48 3 Print Definitions Level 0 Level 1 Lev
52. 1 Roll of Cassettes COIN User Channel On Previous Menu Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Duplex Front Location Opposite of IM Channel Save amp End Session Don t Save amp End Session Same as IM Channel Previous Menu End Configuration Previous Menu 2 Select the desired front side image location 3 35 Film Image Orientation 3 36 The mode defines where the top of the image is located for the KODAK IMAGELINK Digital Workstation The default value is Leading Edge Up LJ Scanner 900 LJ Scanner 9500 E Microimager 70 W Microimager 70 AFM LJ Scanner 923 E Scanner Microimager 990 1 Select Film Image Orientation Mode Number 10 Mode Name MODE10 mA Mode Configuration H Image Management Code MODE 10 Mode Name Ftswitch Pressed Undef TE rch Prg Number 3 Lvl Index Format Ftswitch Released Undef e s gum Supprs IA Display Format Ftswitch Cnf Tone Off S ia Definition 4233 IA Field Widths Patch Reader 1 O ina Mark Si ge Mark Sizes 2112 Level Rules Patch Reader 2 O Image Polarit None Batching Patch Definition Lvl 2 Duplex Port Scalo Auto AEC Mode Bar Code o Film Image Orientation Duplex Film Mode Confirmation Tone NN
53. 2 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Configuration Mode Name MODE10 Field Num Ftswitch Pressed Undef ey T jeld Ftswitch Released Undef Field B Ftswitch Cnf Tone Of Pial C Patch Reader 1 Of ield Patch Reader 2 Off Previous Menu Patch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status Off COIN User Channel On Printer Control Disply Primary DP 1 Of Secondary DP 1 Off Doc Printer 12 Of Document Sorter Of Mode Overrides No Sav Film Definition F Save amp End Session Previous Menu Don t Save amp End Session End Configuration Enter Field Width 0123456789 3 Select the desired field width for the specified field NOTE If you intend to link the current mode with another mode the field width definitions for both modes must be the same If you change the field widths a message appears To avoid E205 errors at powerup first save mode programming then enter a new IA for mode 4 Press Enter 3 9 Description 4 Image Address Fields An Image Address is a unique identifier assigned to each individual document by the Microimager 70 Scanner 900 Scanner 923 Scanner 9500 or Scanner Microimager 990 An Image Address may contain up to 15 characters consisting of a maximum of 12 digits Description
54. 4 Image Address Fields An Image Address is a unique identifier assigned to each individual document by the Microimager 70 Scanner 900 Scanner 923 Scanner 9500 or Scanner Microimager 990 An Image Address may contain up to 15 characters consisting of a maximum of 12 digits and a maximum of 3 delimiters Four fields must be defined Field A represents Level 1 Its value is incremented when a small image mark is placed next to a document and or a document is assigned Level 1 Field B represents Level 2 Its value is incremented when a medium image mark is placed next to a document and or a document is assigned Level 2 Field C represents Level 3 Its value is incremented when a large image mark is placed next to a document and or a document is assigned Level 3 Fixed Field contains fixed information typically the date Example 0301 02 001 000 where Field A contains 000 Field B contains 001 Field C contains 02 Fixed Field contains 0301 The Image Address field lengths are dependent upon the Index Format chosen earlier e Single Level Field A is defined as having a field length greater than zero 1 9 Field B is defined as having a field length of zero 0 Field C is defined as having a field length of zero 0 Fixed Field may be defined if desired 0 9 3 10 A 61097 May 1997 Description 4 Image Address Fields continued e Two Level Field A is defined as having a field length greater than zero 1 9
55. 99 Previous Menu End Configuration Range 1 99 2 Enter the number of documents to be counted as a batch The value entered should be between 1 and the maximum image address size for the field or 9999 whichever is less Use the following information to determine the maximum number allowed If the length of the level field is 1 the maximum batching value is 9 If the length of the level field is 2 the maximum batching value is 99 If the length of the level field is 3 the maximum batching value is 999 If the length of the level field is 4 the maximum batching value is 9999 If the length of the level field is 5 9 the maximum batching value is 99999 A 61097 May 1997 3 15 Start of Batch Function This mode defines the action s to be taken prior to processing the document in the batch The default value is Nothing LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 MH Scanner 9500 1 Select Start of Batch Function Mode Number 10 Mode Name MODE10 Mode Configuration Batching MODE 10 Mode Name Ftswitch Pressed Undef Seat ae 3 Lvl Index Format Ftswitch Released Undef Start of Batch Function Supprs IA Display Format Ftswitch Cnf Tone Off Batch F A 4233 IA Field Widths Patch Reader 1 O End of Batch Function 2112 Level Rules Patch Reader 2 O Previous Menu N
56. A Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Configuration Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch Reader 1 Ofi Patch Reader 2 Off Patch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status Oi COIN User Channel On Printer Control Disply Primary DP 1 Of Secondary DP 1 Off Doc Printer 12 O Document Sorter O Mode Overrides Film Definition Bar Code Reader z Bar Code Reading Status Bar Code Type of Bar Code Characters Bar Codes per Document Distance Between Codes Scan Direction Image Processing Partial Read Enabled Min Partial Characters DSA Patch Reading Status Patch Horizontal Location End Fed Patch Read Status Level Change via Bar Code Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration m Document Codes One Code All Codes Previous Menu 2 Select the desired number of codes to be decoded A 61097 May 1997 Distance Between Codes A 61097 May 1997 This mode defines the minimum bar code height allowed The height of the tallest bar code determines the distance between codes The default v
57. B 2 A 61097 May 1997 P Key Definition Input Code Function Code Name Description Optional F26 AEC Fixed Adjust 26 Allows you to adjust the AEC exposure setting when the AEC is in Fixed Mode OFF F27t Film Advance f27 Allows you to advance the film in six 6 inch 150 mm increments or by a specific amount input in inches or millimetres F28t Film Leader 28 Allows you to create a film leader which is six 6 feet 1 8 metres of blank film Advance Film to End of Roll 29 Allows you to advance the film to the end of the roll F30 Display Film Remaining 30 Allows you to display the amount of film remaining in each film cassette F31 Lead End Code 31 Allows you to create a lead end code for retrieval purposes F32 Trail End Code 132 Allows you to create a trail end code for retrieval purposes F33 Roll Number 33 Allows you to display the current roll number and or change to a new roll number Operator ID Number 134 Allows you to display the current operator ID number and or change to a new operator ID number F35 Cassette ID Number 135 Allows you to display the current cassette ID number and or change to a new cassette ID number F37 Scanner Calibration 137 Allows you to initiate the calibration process required before scanning documents F38 Scanner End of Job 38 Allows you to signal the host computer that the last document of the job has been fed into the transport Printer Character Shift Allows you to select which set
58. C Mode Configuration End Session m MACHINE STATE c User COIN Port Config Baud Rate 9600 Parity Bit None Char Length 8 Bits Handshaking None Update FF Update Previous Menu Baud Rate 300 600 1200 2400 4800 9600 19 2 Previous Menu A 61097 May 1997 5 Select Parity Bit 6 Select the desired parity Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session gt MACHINE STATE __ User COIN Port Config Baud Rate 9600 Parity Bit None Char Length 8 Bits Handshaking None Update FF Update Previous Menu Parity No Parity Odd Parity Even Parity Previous Menu 7 Select Char Length 8 Select the desired character length Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer
59. DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Enter Min Doc Length Not Used Film Definition F Range 2 500 13 00 0002 500 inches Save amp End Session Don t Save amp End Session 0063 499 metric Previous Menu End Configuration 2 Enter the minimum document length within the range 2 5 to 13 inches or 63 50 to 330 20 mm A 61097 May 1997 3 41 Length Error Response This mode defines the action taken if a document is smaller than the minimum length specified or larger than the maximum length specified The default value is Display and Beep E Scanner 900 E Scanner 9500 WE Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Length Err Response Mode Number 10 Mode Name MODE10 3 42 mA Mode Configuration H Length Monitor H MODE 10 Mode Name Ftswitch Pressed Undef ae sasatikenath 3 Lvl Index Format Ftswitch Released Undef Mi E Ocu th i I Supprs IA Display Format Ftswitch Cnf Tone Off lian hh En Bes mee 4233 IA Field Widths Patch Reader 1 o g R 2112 Level Rules Patch Reader 2 O Previous Menu None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer
60. Definition Undef Undef Continuous Documents in Transport Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration 2 Select the desired option 3 46 A 61097 May 1997 Endorser NOTE The Endorser must be installed WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 950 1 Select Endorser 0 Mode Number 10 Mode Name MODE10 mA Mode Configuration Endorser s Status MODE 10 Mode Name Ftswitch Pressed Undef Mod 3 Lvl Index Format Ftswitch Released Undef Bi D a Supprs IA Display Format Ftswitch Cnf Tone O rint Position 4233 IA Field Widths Patch Reader 1 Of Previous Menu 2112 Level Rules Patch Reader 2 O None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Of Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status O 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter O Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration A 61097 May 1997 3 47 Endorser Status Enables or disables the endorser The default value is O
61. Divisor Left Right LUT Status Lookup Table 46231546231 00 00 07 Right No abcdefghijk Start Formula at Left of Decimal Pt Right of Decimal Pt Help Previous Menu Previous Menu 11 Select the LUT Status parameter for definition 12 Select the desired option depending upon whether or not a lookup table will be used Custom Check Digit Definition Check Digit Constant 2 Custom Check Digit Formula Sum of IA Digits Attributes Constant 1 Divisor Parameter Current Value Attributes 46231546231 Constant 1 00 Constant 2 00 Divisor 07 Left Right Right LUT Status No Lookup Table abcdefghijk Help Previous Menu f Lookup Table Status Don t use Lookup Table Use Lookup Table Previous Menu 2 36 A 61097 May 1997 13 Select the Lookup Table parameter for definition 14 Enter the desired lookup table values Custom Check Digit Definition Custom Check Digit Formula Check Digit Constant 2 Sum of IA Digits Attributes Constant 1 Divisor Parameter Current Value Attributes 46231546231 Constant 1 00 Constant 2 00 Divisor 07 Left Right Right LUT Status No Enter lookup table Lookup Table abcdefghijk Req d entry 11 digits Help abcdefghijk Previous Menu To Chan
62. Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Enter Print Position Range 0 125 20 000 Save amp End Session Don t Save amp End Session 0000 250 Previous Menu End Configuration 2 Select the desired print position with the range 0 125 to 75 inches or 3 000 to 1905 000 mm A 61097 May 1997 3 83 Special Character Set 3 84 This mode defines the size font to be printed Select either the smaller or larger font size when using the Document Printer 12 The default value is Use Smaller Font NOTE This selection is not available if the wrong printer driver board is installed The following message appears Incorrect revision of 3100 PCB for Bigfoot Font LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Special Character Set E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 Mode Name MODE10 Mode Configuration Printer Control MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Ftswitch Pres
63. Kodak DIGITAL SCIENCE and IMAGELINK Scanners Installation Questionnaire Instructions A 61097 Part Number 408804 Mode Setup Instructions 1 Introduction The KODAK DIGITAL SCIENCE Mode Setup Software 9000 has been developed to enable you to customize applications using the KODAK DIGITAL SCIENCE Document Scanner 9500 KODAK DIGITAL SCIENCE Scanner Microimager 990 KODAK IMAGELINK Microimager 70 KODAK IMAGELINK Microimager 70 with Advanced Function Module KODAK IMAGELINK Scanner 900 KODAK IMAGELINK Scanner 923 or KODAK IMAGELINK Scanner Microimager 990 The Mode Setup Software offers a user friendly interface which allows you to perform an initial installation or modification of an existing setup The following sections describe the installation requirements installation procedure logon procedure general information regarding use of the Mode Setup Software the Installation Instructions and the Installation Questionnaire and the logout procedure Installation Requirements The following system and cabling requirements should be verified prior to attempting to use the Mode Setup Software The minimum system requirements include e IBM or IBM compatible personal computer e 640K RAM e 1 2 MB hard disk space e 720K 3 1 2 disk drive e monochrome or color display The cabling requirements include e 9 pin serial port adapter or a 25 pin serial port adapter Available through Kodak Parts Services using t
64. Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 Off Patch Reader 2 Off Patch Definition Lvl 2 Bar Code Off Confirmation Tone NNN OCR Status Off COIN User Channel On Printer Control Disply Primary DP 1 Off Secondary DP 1 Off Doc Printer 12 Off Document Sorter Off Mode Overrides No Sav Film Definition F Bar Code Reading Status Bar Code Type of Bar Code Characters Bar Codes per Document Distance Between Codes Scan Direction Image Processing Partial Read Enabled Min Partial Characters DSA Patch Reading Status Patch Horizontal Location End Fed Patch Read Status Level Change via Bar Code Previous Menu z Bar Code Reader Enter Minumum Length Range 03 80 Characters Save amp End Session Previous Menu Don t Save amp End Session End Configuration 03 2 Select the desired minimum length within the range 3 80 A 61097 May 1997 3 63 Bar Codes per Document 3 64 This mode defines the number of bar codes per document to be decoded The default value is One Code LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 E Scanner Microimager 990 Select Bar Codes per Document E Scanner 900 E Scanner 9500 Mode Number 10 MODE 10 Mode Name 3 Lvl Index Format Supprs I
65. Month Date Set Day EEFE Set Year 11 10 1992 Set Hour Set Minute Time Terminal Time 01 40 Previous Menu Yes No 2 22 A 61097 May 1997 4 Select the time or date component you wish to define month day year hour or minute 3 Verify that the terminal time should be downloaded by selecting Yes or to cancel the download select No If the computer being used to program the unit does not have an internal clock or the internal clock is not accurate Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session Mainframe Configuration gt MACHINE STATE Set System Clock Set Month Date Set Day Set Year 11 10 1992 Set Hour Set Minute Ti ime Terminal Time 01 40 Previous Menu Enter a new month below 11 To Change Enter Value To Retain Press Enter 5 Enter a value for the component selected A 61097 May 1997 2 23 Version Numbers This option displays the current software version s
66. N Image Offset 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Previous Menu Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Image Orientation Leading Edge Down Save amp End Session Don t Save amp End Session Leading Edge Up Previous Menu End Configuration Previous Menu 2 Select the desired image orientation A 61097 May 1997 Image Offset A 61097 May 1997 This mode defines the position of the image marks relative to the leading edge of the document The default value is 0 WE Microimager 70 W Microimager 70 AFM LI Scanner 923 1 Select Image Offset E Scanner Microimager 990 LJ Scanner 900 LJ Scanner 9500 H Image Management Code H Mode Number 10 Mode Name MODE10 ml Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone Off 4233 IA Field Widths Patch Reader 1 O 2112 Level Rules Patch Reader 2 O None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgm
67. Previous Menu Don t Save amp End Session End Configuration Batch Field Level 1 Level 2 Level 3 None Previous Menu 2 Select the desired batch level NOTE If you select None you can t set Batch Value 3 14 A 61097 May 1997 Batch Value Defines the number of documents to be counted prior to performing a predefined action The default value is 99 WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 MH Scanner 9500 1 Select Batch Value Mode Number 10 Mode Name MODE10 m Mode Configuration Batching MODE 10 Mode Name Ftswitch Pressed Undef Baten Wie 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone 0 Start of Batch Function 4233 IA Field Widths Patch Reader 1 O End of Batch Function 2112 Level Rules Patch Reader 2 O Previous Menu None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code Oi Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Oi Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 Ofi Xport Check Stacker Document Sorter O Off Endorser Mode Overrides No Sav Not Used Film Definition F Enter Batch Value Save amp End Session Don t Save amp End Session
68. Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off lt PatchField Xport Check Stacker Document Sorter Off Level 1 Off Endorser Mode Overrides No Sav Level 2 Not Used Film Definition F Level 3 None Save amp End Session Don t Save amp End Session Previous Menu Previous Menu End Configuration 2 Select the desired level A 61097 May 1997 3 57 Film Transfer Patches 3 58 This mode defines whether or not a document containing a transfer patch is to be filmed The default value is Transfer Patch Filmed L Microimager 70 W Microimager 70 AFM L Scanner 923 E Scanner Microimager 990 1 Select Film Transfer Patches LJ Scanner 900 LJ Scanner 9500 a Patch Definition Transfer Patch Definition Film Transfer Patches Patch Recognition Previous Menu Transfer Patch Xfer Patch NOT Filmed Xfer Patch Filmed Previous Menu Mode Number 10 Mode Name MODE10 m Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl ndex Format Ftswitch Released Undef Supprs A Display Format Ftswitch Cnf Tone Off 4233 A Field Widths Patch Reader 1 O 2112 Level Rules Patch Reader 2 Of None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code
69. Select the desired status 93 A 61097 May 1997 3 79 Transmit Data This mode defines the data output via the COIN2 port when a user defined protocol User Defined KDIS Format or User Defined Protocol is chosen during machine definition The default values are FF IA for all levels LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 MH Scanner 9500 lf the same information is to be transmitted for documents of all levels 1 Select Define All Levels Transmit Items Current Transmit Sequence Full Image Address ndexed Field s Only Current Field Value Current Day Current Date Current Time Document Counter Roll Number New Transmit Sequence Attachment Count Bar Code Data Nothing Previous Menu lt FF IA gt When using a Microimager 70 with the Advanced Function Module installed Scanner 900 Scanner 923 Scanner 9500 or Scanner Microimager 990 all of the transmit items are available for selection with a maximum of seven 7 items 2 Select the item s to be transmitted 3 80 A 61097 May 1997 A 61097 May 1997 lf different information is to be transmitted for documents of different levels 1 Select Define Level for the desired level H Transmit Items Current Transmit Sequence Full Image Address Indexed Field s Only lt FF IA gt Current Field Value
70. Session Don t Save amp End Session Kodak Standard Previous Menu End Configuration Previous Menu 2 Select the desired Image Mark Size option Custom Setup should only be selected if the Kodak Field Engineer has defined the customer image mark sizes small medium and large A 61097 May 1997 3 33 Image Polarity 3 34 This mode defines the polarity of the image marks relative to the polarity of the document images The default value is Same as Image Mark WE Microimager 70 W Microimager 70 AFM LJ Scanner 900 LJ Scanner 923 E Scanner Microimager 990 J Scanner 9500 1 Select Image Polarity Mode Number 10 Mode Name MODE10 m Mode Configuration H Image Management Code Status MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef es ee Pro Number Supprs IA Display Format Ftswitch Cnf Tone Off S ae oe 4233 IA Field Widths Patch Reader 1 O eae tee aes 2112 Level Rules Patch Reader 2 ot lone polart None Batching Patch Definition Lvl 2 g y 4 Auto AEC Mode Bar Code O Duplex Front Location Duplex Film Mode Confirmation Tone NNN eu mage Orientation 27 Reduction Ratio OCR Status Off 9 1 Roll of Cassettes COIN User Channel On Previous Menu Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Docum
71. Template Previous Menu When using a Microimager 70 without the Advanced Function Module installed a limited number of items may be selected The available items are e Print Template 1 e No Print Template When using a Microimager 70 with the Advanced Function Module installed all of the print templates defined during machine configuration are available for selection 4 Select the print template which contains the information to be printed on all documents 3 100 A 61097 May 1997 Document Sorter OFF E Scanner 923 LJ Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Select Document Sorter and the following screen appears Mode Number 10 m Sor Criteria Mode Name MODE10 Bin Default Stopper Level 0 Docs Level 1 Docs Level 2 Docs Level 3 Docs Transfer Patch Level III Patch Level II Patch Bar Code Docs Partial Read BC Docs w o Bar Code BC Patch Docs Skewed Documents Length Error Docs Defaul Default Default Default Upper Defaul Default Default Defaul Defaul Defaul Save amp End Session Previous Menu Don t Save amp End Session End Configuration m Document Sorter Status Error Response Sort Criteria m Status Off or Disable On or Enabled m Error Response Display Only Beep and Display
72. Three level offset Image Address Display Format DISP Display SUPP Suppress COMP Compress C 1 Tem eserinton vanes 22 0 Image Address Field Widths 23 0 Level Rules Batching Level Value Start of Batch function End of Batch function Reduction Ratio Film Writer Character Orientation Image Addres Display Format Write Definitions Image Management Code Status Search Program Number Magnification Splice Definition C 2 94 go to Level 1 95 go to Level 2 f96 go to Level 3 94 go to Level 1 95 go to Level 2 f96 go to Level 3 98 stop AEC Mode Auto Fixed Film Mode Level 0 Level 1 Level 2 Level 3 None Level 1 Level 2 Level 3 01 9999 SIM Simplex DUP Duplex DUO Duo Don t Care 24X 40X 50X Com Comic CIN Cine COM180 Comic 180 CIN180 Cine 180 DISP Display SUPP Suppress COMP Compress Enter item s ON Enabled OFF Disabled 00 70 20 80 Ignore Level 1 Level 2 Level 3 Image Mark Sizes Image Polarity Duplex Front Location Film Image Orientation Image Offset Length Monitor Status Maximum Document Length Minimum Document Length Error Response Skew Monitor Status Threshold Error Response Chek Stacker Endorser Status Mode Print Position Trem Description vanes CUST Custom KOD Kodak Standard OPP Opposit
73. Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session A 61097 May 1997 2 13 Message 0 is predefined and cannot be changed Messages 1 through 9 are programmable using the following sequence of steps 1 Select a message number 2 Press Return Enter 3 Enter the desired message text 4 Press Return Enter L a a e Definition Diagnostic Message No Entry Allowed ol SIN Sl al A wl N Alo Prev Previous Menu 2 14 A 61097 May 1997 Print Template Setup This option defines as many as ten 10 unique print templates The template definitions are used when programming Document Printer 12 print definitions The default print template is Print Template 1 which prints Full IA w No Delimiters on Line 1 LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select DP 12 Print Template 2 Select a print template 1 10 m Mainframe Configuration m MACHINE STATE Display Machine Accessories Machine ID Number Display Language Measurement System m Print Templates Pr
74. Tone NNN Partial Read Enabled 2222 Reduction Ratio OCR Status Off Min Partial Characters 1 Roll of Cassettes COIN User Channel On DSA Patch Reading Status Comic Film Writer Printer Control Disply Patch Horizontal Location Off Image Mgmt Code Primary DP 1 Off End Fed Patch Read Status Off Length Monitor Secondary DP 1 Off Level Change via Bar Code Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Previous Menu Off Endorser Mode Overrides No Sav Not Used Film Definition F Bar Code Type Code 39 Save amp End Session Don t Save amp End Session cae 2 Previous Menu End Configuration Previous Menu 2 Select the desired bar code type NOTE Only one type of bar code may be read using a given mode However different modes may be defined as reading different types of bar code A 61097 May 1997 Number of Bar Code Characters This mode defines the minimum bar code length allowed in terms of the number of characters encoded The default value is 3 LJ Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select of Bar Code Characters E Scanner 900 E Scanner 9500 Mode Number 10 mA Mode Configuration MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length
75. Transfer Patches Off Length Monitor Secondary DP 1 Of Type 3 amp Transfer Patches Off Skew Monitor Doc Printer 12 Off Type 2 3 amp Xfer Patches Xport Check Stacker Document Sorter O Off Endorser Mode Overrides No Sav Previous Menu Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 2 Select the patch code type s to be processed by the system A 61097 May 1997 3 59 Bar Code NOTE A Bar Code Reader must be installed LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Bar Code 3 60 Mode Number 10 Mode Name MODE10 m Mode Configuration H Bar Code Reader MODE 10 Mode Name Ftswitch Pressed Undef Bar Code Reading Status 3 Lvi Index Format Ftswitch Released Undef Bar Code Type Supprs IA Display Format Ftswitch Cnf Tone 0 of Bar Code Characters 4233 IA Field Widths Patch Reader 1 O Bar Codes per Document 2112 Level Rules Patch Reader 2 Of Distance Between Codes None Batching Patch Definition Lvl 2 Scan Direction Auto AEC Mode Bar Code 0 Image Processing Duplex Film Mode Confirmation Tone NNN Partial Read Enabled 22222 Reduction Ratio OCR Status Off Min Partial Characters 1 Roll of Cassettes COIN User Channel On A Comic Film Writer Printer Control Disply PSAE aton Reading Stati R Off Image Mgmt Code Primary
76. ables a confirmation tone issued when a patch document is detected The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 E Scanner Microimager 990 Select Patch Detected Tone E Scanner 900 E Scanner 9500 Mode Number 10 MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Configuration Mode Name MODE10 Confirmation Tone Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch Reader 1 Ofi Patch Reader 2 Off Patch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status Oi COIN User Channel On Printer Control Disply Primary DP 1 Off Secondary DP 1 Off Doc Printer 12 O Document Sorter O Mode Overrides No Sav Film Definition F Patch Detected Tone Bar Detected Tone Bar Code Patch Tone Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration Ta Patch Tone Off or Disabled On or Enabled Previous Menu 2 Select the desired status NOTE If the Patch Detected Tone is enabled the Bar Code Patch Tone cannot be enabled However the Bar Detec
77. ailable on the scanners 3 28 A 61097 May 1997 Status This mode enables or disables the use of IMC options The default value is Off or Disabled W Microimager 70 W Microimager 70 AFM LJ Scanner 900 LJ Scanner 923 E Scanner Microimager 990 J Scanner 9500 1 Select Status A 61097 May 1997 Mode Number 10 Mode Name MODE10 mA Mode Configuration H Image Management Code H MODE 10 Mode Name Ftswitch Pressed Undef ieee h Prg Number 3 Lvl Index Format Ftswitch Released Undef M nesi tg ume Supprs IA Display Format Ftswitch Cnf Tone Off S en Definition 4233 IA Field Widths Patch Reader 1 O Troe Mark Si ge Mark Sizes 2112 Level Rules Patch Reader 2 O Image Polarit None Batching Patch Definition Lvl 2 Du E Po oain Auto AEC Mode Bar Code O Fi Image Ori i x n i ge Orientation Duplex Film Mode Confirmation Tone NNN Image Offset 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Previous Menu Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F IMC Status Off or Diabled Save amp End Session Don t Save amp End Session On or Enabled Previous Menu End Configuration Previous Menu 2 Select the desired status remaining IMC op
78. ally Single Stamp will activate the Endorser only once per document The default value is Continuous W Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 E Scanner 900 E Scanner 9500 1 Select Mode Mode Number 10 Mode Name MODE10 m Mode Configuration Endorser MODE 10 Mode Name Ftswitch Pressed Undef S 3 Lvl Index Format Ftswitch Released Undef Print Positi Supprs IA Display Format Ftswitch Cnf Tone Off TIDER OSTHON 4233 IA Field Widths Patch Reader 1 Of Previous Menu 2112 Level Rules Patch Reader 2 Of None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Of Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Of Off Length Monitor Secondary DP 1 Of Off Skew Monitor Doc Printer 12 Of Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Endorser Mode Continuous Save amp End Session Don t Save amp End Session Single Stamp Previous Menu End Configuration Previous Menu 2 Select the desired mode A 61097 May 1997 3 49 Endorser Print Position This mode defines how far from the leading edge of the document the endorsement will appear The default value is 0000 250 inch 6 350 mm WE Microimager 70 W Microimag
79. alue is 1 000 inch 25 400 mm LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Distance Between Codes E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Configuration Mode Name MODE10 NOTE Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef ff ff aIR gt RIS N Zz SARAARAARG B lt 7Z09 909090902905 999 n D lt Distance between bar codes must be greater than height of largest bar code HINT Always add one click to height of largest code Save amp End Session Previous Menu Don t Save amp End Session End Configuration Distance Between Codes 1 000 25 400 mm Default Press ENTER to return to Previous Menu 0 375 in 3 000 in a L 9 53 mm 76 20 mm 2 Select the desired bar
80. and or a document is assigned Level 1 the Image Address is unchanged 3 6 A 61097 May 1997 Image Address Display Format A 61097 May 1997 This mode defines the format of the Image Address display which appears on the control panel The default is Suppress LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select IA Display Format E Scanner Microimager 990 E Scanner 900 E Scanner 9500 3 Lvl Supprs 4233 2112 None Auto Duplex Mode Number 10 Mode Configuration MODE 10 Mode Name Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Of Patch Reader 1 Off Patch Reader 2 Of Patch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status Of COIN User Channel On Printer Control Disply Primary DP 1 Off Secondary DP 1 Of Doc Printer 12 Off Document Sorter Of Mode Overrides No Sav Film Definition F Save amp End Session Previous Menu Don t Save amp End Session End Configuration m Examples of Formats Display 001 002 003 004 Compress 001 2 3 4 Suppress 001 2 3 4 IA Display Format Display Leading Zeros Compress Leading Zeros Suppress Leading Zeros Previous Menu
81. and the check digit is greater than nine 9 A 61097 May 1997 2 33 To program a custom check digit algorithm use the following sequence of steps 1 Select the Attributes parameter for definition 2 Enter the desired attribute values Custom Check Digit Definition Check Digit Constant 2 Custom Check Digit Formula Sum of IA Digits Attributes Constant 1 Divisor Parameter Current Value Attributes 46231546231 Constant 1 Constant 2 00 Divisor 07 Left Right Right LUT Status No n Enter attribute values Lookup Table abcdefghijk Req d entry 11 digits Help 46231546231 Previous Menu To Change Enter Value To Retain Press Enter 3 Select the Constanti parameter for definition 4 Enter a value between 00 99 Custom Check Digit Definition Check Digit Constant 2 Custom Check Digit Formula Sum of IA Digits Attributes Constant 1 Divisor Parameter Current Value Attributes 46231546231 Constant 1 Constant 2 00 Divisor 07 Left Right Right LUT Status No 7 Enter constant 1 Lookup Table abcdefghijk Req d entry 2 digits Help 00 Previous Menu To Change Enter Value To Retain Press Enter 2 34 A 61097 May 1997 5 Select the Constant2 parameter for definition 6 Enter a value between 00 99 Cust
82. ant2 and the first digit to the left of the decimal point If Constant2 is zero the first digit to the left of the decimal point becomes the check digit lf Constant2 is not zero and the Left Right specifier is Right the check digit equals the difference between Constant2 and the first digit to the right of the decimal If Constant2 is zero the first digit to the right of the decimal point becomes the check digit LUT Lookup Table Status lIf Yes the final check digit calculated is used as an index into a lookup table If No is specified the lookup table is ignored e Lookup table A table of check digit values refer to Table 2 Table 2 Default Lookup Table values ESR EAE DEES EES A 61097 May 1997 2 31 Sample check digit calculation 1 Assume the following 123 45 678 912 Image Address Attributes 46231546231 Constant 1 7 Constant 2 10 Divisor 11 Left Right Right LUT Status No off Lookup Table abcdefghijk Then the check digit calculation would be 1 Setup the equation Check Digit 10 Calculation 1 7 Calculation 1 2 x 1 1 x 3 9 x 2 8x 6 7 x 4 6x 5 5 x 1 4x 3 3x 2 2x6 1x4 2 Calculate the value of the fraction 168 7 15 91 3 Apply the Left Right parameter 15 91 5 if Left is specified 15 91 9 if Right is specified In this example 9 isused lt 4 Complete the calculation 10 9 1 In this example 1 is the check
83. are Mode 1 Single Level Mode 2 Two Level Offset Mode 3 Two Level Mode 4 Three Level Offset Mode 5 Three Level Mode 6 Two Level Mode 7 Two Level Offset When using a Microimager with the Advanced Function Module installed Scanner 900 Scanner 923 Scanner 9500 or Scanner Microimager 990 the index format for all modes may be defined 1 Select Index Format Mode Number 10 Mode Name MODE10 Mode Configuration Index Format K MODE 10 Mode Name Ftswitch Pressed Undef Singlo Level A wo Level 3 Lvl Index Format Ftswitch Released Undef Three Level Supprs IA Display Format Ftswitch Cnf Tone Off Two Level Offset 4233 IA Field Widths Patch Reader 1 Off Three Lev i E 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Previous Menu Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 2 Select the desired index format option NOTE If you intend to link the current mode with another mode the index format chos
84. at Ftswitch Cnf Tone Of Same Format per Level 4233 IA Field Widths Patch Reader 1 Of Print Sequence Level 0 2112 Level Rules Patch Reader 2 Of Print Sequence Level 1 None Batching Patch Definition Lvl 2 Print Sequence Level 2 Auto AEC Mode Bar Code Of Print Sequence Level 3 Duplex Film Mode f Confirmation Tone NNN Previous Menu 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Of Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Of Off Endorser Mode Overrides No Sav Not Used Film Definition F H DP 12 Font Selection s 7 Comic Orientation Save amp End Session Don t Save amp End Session Comic 180 Orientation Previous Menu End Configuration Previous Menu 2 Select the desired size and font COMIC SIO 3 98 A 61097 May 1997 Print Definitions DP12 This mode defines the information printed on each document based upon the document level The default values are No Print Template for Level 0 documents Print Template for Level 1 Level 2 and Level 3 documents The default is IA No Del W Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 If the same information is to be printed on documents of all levels 1 Select Same Format per Level
85. ave amp End Session 0330 20 metric Previous Menu End Configuration 2 Enter the maximum document length within the allowable range for your machine type Microimager 70 2 5 to 75 inches or 63 to 1905 mm Scanner 900 2 5 to 20 inches or 63 to 508 00 mm Scanner 923 2 5 to 20 inches or 63 to 508 00 mm Scanner 9500 2 5 to 30 inches or 63 to 762 mm Scanner Microimager 990 2 5 to 2 0 inches or 63 50 to 508 00 mm 3 40 A 61097 May 1997 Minimum Document Length This mode defines the minimum document length accepted The default value is 02 500 inches 63 mm E Scanner 900 E Scanner 9500 W Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Min Document Length Mode Number 10 Mode Name MODE10 mA Mode Configuration Length Monitor H MODE 10 Mode Name Ftswitch Pressed Undef A A Length 3 Lvi Index Format Ftswitch Released Undef Min D t Length Supprs IA Display Format Ftswitch Cnf Tone Off in Pocument eng 4233 IA Field Widths Patch Reader 1 Off Length Err Response 2112 Level Rules Patch Reader 2 Off Previous Menu None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary
86. ber 3 Message Number 4 Message Number 5 Message Number 6 Message Number 7 Message Number 8 Message Number 9 4 Select the desired message number The Document Printer 12 may print as many as twelve 12 lines per document each print line can be up to twelve 12 characters long and contain as many as three print items The location of the twelve lines is defined in terms of a master template which is thirty eight 38 lines high and twelve characters wide for the small font and twenty six 26 lines high and twelve 12 characters wide for the large font A 61097 May 1997 2 17 The master template is designed to assist you in the placement of information printed by the Document Printer 12 Follow these steps to use the master templates 1 2 Obtain a sample of the customer s document s Determine the starting print position how far from the leading edge of the document printed information should appear Draw a line on the sample document which corresponds to the starting print position 4 Copy the master template onto a transparency 5 Align the top dotted line of the master template with the line drawn on the sample document to achieve proper vertical placement Position the master template so that the window is aligned with the position of the Document Printer 12 in the transport to achieve proper horizontal placement The area in which printed information may appear should now be hi
87. ble scanning etc toggle Accessory Status Allows you to display the current status of each accessory installed Allows you to assign Level 0 to the next document fed into the transport Last Image Address Allows you to display the Image Address of the last document processed Total Document Count Allows you to display the total number of documents processed Also allows you to reset the count to zero Level 0 Count Allows you to display the total number of documents assigned Level 0 Also allows you to reset the count to zero Level 1 Count Allows you to display the total number of documents assigned Level 1 Also allows you to reset the count t May be executed while transport is running Available when filming for use only with Microimager 70 with or without AFM and Scanner Microimager 990 Available when scanning for use only with the Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 Available when using advanced capabilities for use only with the Microimager 70 with AFM Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 A 61097 May 1997 B 1 P Key Definition Input Code Function Code Name Description Optional F12t Level 2 Count Allows you to display the total number of documents assigned Level 2 Also allows you to reset the count to zero Level 3 Count Allows you to display the total number of documents assigned Level 3 Also allows you to reset the cou
88. ch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status Of COIN User Channel On Printer Control Disply Primary DP 1 Of Secondary DP 1 Of Doc Printer 12 Of Document Sorter Of Mode Overrides No Sav Film Definition F Transfer Patch Definition Film Transfer Patches Patch Recognition Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration A 61097 May 1997 Transfer Patch Definition E Scanner 923 W Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 Select Transfer Patch Definition This mode defines which level should be assigned to the next document when a transfer patch is used The default value is Level 2 E Scanner 900 E Scanner 9500 Mode Number 10 Mode Name MODE10 SS _ Mode Configuration Patch Definition MODE 10 Mode Name Ftswitch Pressed Undef Transfer Patch Definition 3 Lvi Index Format Ftswitch Released Undef Film Transfer Patches Supprs IA Display Format Ftswitch Cnf Tone Off Patch Recognition 4233 IA Field Widths Patch Reader 1 Off Previous Menu 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code
89. ches on the document s in terms of the distance from the left side of the transport The default value is 5 12 inches 130 048 mm LJ Microimager 70 M amp M Microimager 70 AFM E Scanner 923 1 Select Patch Horizontal Location E Scanner Microimager 990 LJ Scanner 900 E Scanner 9500 Mode Number 10 Mode Configuration Bar Code Reader MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Of Patch Reader 1 Of Patch Reader 2 Of Patch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status Of COIN User Channel On Printer Control Disply Primary DP 1 Of Secondary DP 1 Of Doc Printer 12 Of Document Sorter Of Mode Overrides No Sav Film Definition F Save amp End Session Previous Menu Don t Save amp End Session End Configuration Bar Code Reading Status Bar Code Type of Bar Code Characters Bar Codes per Document Distance Between Codes Scan Direction Image Processing Partial Read Enabled Bar Code Patch Position 5 120 130 048 mm Default Press ENTER to return to Previous Menu
90. code height distance between codes within the range 0 375 inch to 3 inches or 9 53 mm to 76 20 mm by pressing the left right arrow key s to decrement increment the default value by 0 125 inch or 3 18 mm at a time 3 65 Scan Direction 3 66 This mode defines whether the bar codes may be read in only one direction from left to right or in either direction from left to right or from right to left The default value is Unidirectional from left to right only LJ Microimager 70 M amp M Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Scan Direction Mode Number 10 Mode Name MODE10 m Mode Configuration H Bar Code Reader MODE 10 Mode Name Ftswitch Pressed Undef Bar Code Reading Status 3 Lvi Index Format Ftswitch Released Undef Bar Code Type Supprs IA Display Format Ftswitch Cnf Tone 0 of Bar Code Characters 4233 IA Field Widths Patch Reader 1 Of Bar Codes per Document 2112 Level Rules Patch Reader 2 O Distance Between Codes None Batching Patch Definition Lvi 2 Scan Direction Auto AEC Mode Bar Code Of Image Processing Duplex Film Mode Confirmation Tone NNN Partial Read Enabled 2222 Reduction Ratio OCR Status Off Min Partial Characters 1 Roll of Cassettes COIN User Channel On DSA Patch Reading Status Comic Film Writer Printer Control Disply Patch Horizontal Location Off Image Mgmt Code Primary DP 1 Of End Fed Patch Read Stat
91. croimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 A 61097 May 1997 2 1 Display Machine Accessories This option displays the status of the various machine accessories and is for viewing only no selections or entries are made W Microimager 70 W Microimager 70 AFM E Scanner 923 1 E Scanner Microimager 990 Select Display Machine Accessories E Scanner 900 E Scanner 9500 2 Press Return Enter to close the Accessory Status window Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session m MACHINE STATE Accessory Endorser Check Stacker Image Marker Film Writing Adv Doc Control Patch Head 1 Patch Head 2 Front BC Board Front DSA Rear BC Board Rear DSA Print Controller Primary DP 1 Secondary DP 1 Doc Printer 12 OCR Document Sorter Status Not Present Not Present Present Present Present Present Not Present Not Present Present Not Present Not Present NOTE On scanners 900 923 and
92. ct Set System Clock WE Scanner Microimager 990 W Scanner 9500 Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session Mainframe Configuration gt MACHINE STATE Set System Clock Set Month Date Set Day Set Year 11 10 1992 Set Hour Set Minute i Time Terminal Time 01 40 Previous Menu If the computer being used to program the unit has its own internal clock 2 Select Terminal Time to download the time and date Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session Mainframe Configuration m MACHINE STATE c Set System Clock Set
93. cument Distance Between Codes Scan Direction Image Processing Partial Read Enabled Min Partial Characters DSA Patch Reading Status Patch Horizontal Location End Fed Patch Read Status Level Change via Bar Code Previous Menu End Fed Patch Save amp End Session Previous Menu Don t Save amp End Session End Configuration Off or Disabled On or Enabled Previous Menu 2 Select the desired status NOTE If patch reading is enabled using the DSA make certain to complete the Patch Definition items Also end fed patches must be located within 3 75 inches or 95 3 mm of the leading edge of 3 72 the document s A 61097 May 1997 Level Change via Bar Code Enables level changes based upon detection of a bar code The default value is Undefined LJ Scanner 900 E Scanner 9500 LJ Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Level Change via Bar Code Mode Number 10 Mode Name MODE10 Mode Configuration Bar Code Reader E MODE 10 Mode Name Ftswitch Pressed Undef a Foils oe Status 3 Lvl Index Format Ftswitch Released Undef of Bar C yr Character Supprs IA Display Format Ftswitch Cnf Tone Off ah ees a DOEN 4233 IA Field Widths Patch Reader 1 Off Distance pinsen Codes 2112 Level Rules Patch Reader 2 Off Scan Direction None Batching Patch Defi
94. d Min Partial Characters DSA Patch Reading Status Patch Horizontal Location End Fed Patch Read Status Level Change via Bar Code Previous Menu Enter Minumum Length Range 05 80 Characters Mode Number 10 Mode Name MODE10 Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone Off 4233 IA Field Widths Patch Reader 1 Off 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 05 2 Select the desired number of characters 3 69 DSA Patch Reading Status Enables or disables patch reading using the Document Scanning Array The default value is Off or Disabled E Scanner 900 E Scanner 9500 LJ Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select DSA Patch Reading Status Mode Number 10 Mode Name MODE10 3 70
95. d Film Definition F OCR Status Off or Disabled Save amp End Session Don t Save amp End Session On or Enabled Previous Menu End Configuration Previous Menu 2 Select the desired status 3 78 A 61097 May 1997 COIN User Channel NOTE If the machine definition User COIN Port Protocol was disabled these definitions will be ignored Enables or disables the COIN2 user channel If a standard form of output was chosen during machine definition Bar Code KDIS Protocol or OCR Data Protocol this definition should be set to Enabled which will produce default standard data output via the COIN2 port If a user defined form of output was chosen during machine definition User Defined KDIS Format or User Defined Protocol select Define All Levels or select a particular level The default value is Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select COIN User Channel Mode Number 40 Mode Name MODEIO Modo Cai quire born MOCE 10 Mode Mane sLv Irox F omat Suppr 14 Depiay Format 4233 1A Fiad Widths iiz Lod Fake RRREE rc P Lea COIN Pot Stabe Deabied Eratied une datadi Detire All Levee Dare Low O Dare Lowe i Dare Low 2 Dare Low S Frasas Meru ow NNN ov OM Ce Image Mant Code Lergh Monitor Skew Monir Savo 4 Erd Sesion Dont Save 4 End Sesion Proso Meru End Confiquration 2
96. digit The Image Address printed by the Document Printer would be 123 45 678 9121 NOTE Because only one position is reserved the check digit defaults to zero when the following conditions occur e The Lookup Table is used and the check digit is greater than ten 10 e The Lookup Table is not used and the check digit is greater than nine 9 2 32 A 61097 May 1997 Sample check digit calculation 2 Assume the following Image Address 123 45 678 912 Attributes 46231546231 Constant 1 F Constant 2 10 Divisor 11 Left Right Right LUT Status Yes on Lookup Table abcdefghijk Then the check digit calculation would be 1 Set up the equation Check Digit 10 Calculation 1 7 Calculation 1 2 x 1 1 x 3 9 x 2 8 x 6 7 x 4 6 x 5 5x 1 4x3 3x2 2x6 1x4 Calculate the value of the fraction 168 7 15 91 lt Apply the Left Right parameter 15 91 5ifLeftis specified 15 91 9 if Right is specified In this example 9 is used Complete the calculation 10 9 1 Apply the Lookup Table values 1 cross references to B In this example 1 is the check digit The Image Address printed by the Document Printer would be 123 45 678 912B NOTE Because only one position is reserved the check digit defaults to zero when the following conditions occur e The Lookup Table is used and the check digit is greater than ten 10 e The Lookup Table is not used
97. e foe Joe fe f March 1 1991 Slash Dash Period Space None 2 10 A 61097 May 1997 Time Format This option defines the time display format Refer to Description 2 Time Format Samples for a description of the available formats The default is 12 hour with AM PM LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 Ml Scanner 9500 1 Select Time Format 2 Select a specific time format Mainframe Configuration Display Machine Accessories MACHINE STALE Machine ID Number Display Language Set Time Format Measurement System Programmable Function Keys 12 Hour with AM PM Date Format 12 Hour without AM PM Time Format 24 Hour Alarm Tone Doc Printer Film Writer Msg Previous Menu DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session Description 2 Time Format Samples 12 hour with AM PM 5 00 PM 12 hour without AM PM A 61097 May 1997 2 11 Alarm Tone This option defines tone or pitch of the audible alarm The default is High LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 2 Select the desired alarm tone pitch Select Alarm Tone E Scanner 900 E Scanner Microimager 990 W Scanner 9500
98. e items are e Full IA w All Delimiter e Indexed Fields Only e Nothing Printed When using a Microimager 70 with the Advanced Function Module installed all of the items are available for selection with a maximum of 38 characters including spaces If Check Digit is selected the following window is displayed NOTE If the definition exceeds the thirty eight 38 character limits the first thirty eight 38 characters will be printed on each document and the remainder of the information will be truncated 2 Select the item s to be printed A 61097 May 1997 3 89 Secondary Document Printer 1 NOTE Two Document Printer 1 accessories must be installed LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 E Scanner Microimager 990 Select Secondary DP 1 E Scanner 900 E Scanner 9500 Mode Number 10 mA Mode Configuration MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Of Patch Reader 1 Off Patch Reader 2 Oi Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 D
99. e of IM SAME Same as IM OPP Opposite of channel SAME Same as channel DN Leading Edge down UP Leading Edge up 000 127 ON Enabled OFF Disabled 02 5000 75 000 in 63 5 1905 mm on IL70 63 5 508 on others 02 500 13 000 in 63 5 330 2 mm DISP Display BEEP Display and Beep STOP Stop and Display ON Enabled OFF Disabled 5 5 degrees 10 10 degrees DISP Display BEEP Display and Beep STOP Stop and Display ON Enabled OFF Disabled ON Enabled OFF Disabled CON Continuous SIN Single Stamp 00 000 70 000 in 0 1778 mm hoo Footswitch Pressed OFF Undefined Level 0 Level 1 Level 2 Level 3 INC Increment SLevel 0 Sustained SLevel 1 Sustained SLevel 2 Sustained SLevel 3 Sustained F Key P Key A 61097 May 1997 Tem Description vanes Footswitch OFF Undefined Released Level 0 Level 1 Level 2 Level 3 INC Increment Footswitch ON Enabled Confirmation Tone ore Disabled Patch Reader 1 ON Enabled OEF Disabled Patch Reader 2 ON Enabled A Disabled Patch Definition Transfer Patch Level 1 Definition Level 2 Level 3 None Film Transfer Patch NO not filmed YES filmed Patch Recognition 2 Type 2 3 Type 3 XFER Transfer 2 3 Types 2 and 3 2X Types 2 and Transfer 3X Types 3 and Transfer ALL All types Bar Code Status ON Enabled OFF Disabled Bar Code Type 3 o
100. el 2 Level 3 49 0 Document Sorter 49 1 Status 49 2 Error Response 49 3 Sort Criteria Default Hopper Item 1 Location Item 2 Location Item 3 Location 50 0 Mode Overrides 51 0 Film Definition MODE 1 A 61097 May 1997 APPENDIX A System Map m Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save to PC Load from PC Mode Configuration End Session Programmable Function Keys m MACHINE STATE c Mode Configuration Define Mode 1 Define Mode 2 Define Mode 3 Define Mode 4 Define Mode 5 Define Mode 6 Define Mode 7 Define Mode 8 Define Mode 9 Define Mode 10 Define Mode 11 Define Mode 12 Define Mode 13 Define Mode 14 Define Mode 15 Define Mode 16 Define Mode 17 Mode to Mode Copy End Session Previous Menu Define Mode 18 Mode Number 10 m Mode Configuration Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 Off Patch Reader 2 Off Patch Definition Lvl 2 Bar Code On Confirmation Tone NNN OCR Status Off COIN User Channel On Printer Control Disply Primary DP 1 Of
101. en for both modes must be the same 3 4 A 61097 May 1997 Description 3 Index Formats There are five Index Format options available Single Level i f a a E i i i i Level 1 Level 1 Level 1 Level 1 Whenever a small image mark is placed next to a document and or a document is assigned Level 1 the Image Address field associated with Level 1 Field A is incremented Two Level g IA 1 0 E IA 1 1 g IA 1 2 a IA 2 0 E i i a Level 2 Level 1 Level 1 Level 2 Whenever a medium image mark is placed next to a document and or the document is assigned Level 2 the Image Address field associated with Level 2 Field B is incremented and the field associated with Level 1 Field A is set to zero Whenever a small image mark is placed next to a document and or a document is assigned Level 1 the Image Address field associated with Level 2 Field B is unchanged and the field associated with Level 1 Field A is incremented Two Level Offset Level 2 Level 1 Level 1 Level 2 Whenever a medium image mark is placed next to a document and or a document is assigned Level 2 the Image Address field associated with Level 2 Field B is incremented Whenever a small image mark is placed next to a document and or a document is assigned Level 1 the Image Address is unchanged A 61097 May 1997 3 5 Description 3 Index Formats continued Three Level E IA 1 0 0 a IA 1 1 0 a IA 1 1 1 a IA 2 0 0
102. ent Sorter Oi Off Endorser Mode Overrides No Sav Not Used Film Definition F Image Polarity Opposite of Image Mark Save amp End Session Don t Save amp End Session Same as Image Mark Previous Menu End Configuration Previous Menu 2 Select the desired polarity option NOTE Select Opposite of Image Mark only when splicing the Image Management Code onto the leading edge of film on which the image mark polarity is opposite the document image polarity A 61097 May 1997 Duplex Front Location A 61097 May 1997 The mode defines for the KODAK IMAGELINK Digital Workstation where the front side image is located The default value is Same as IM Channel LJ Scanner 900 LJ Scanner 9500 WE Microimager 70 W Microimager 70 AFM LJ Scanner 923 E Scanner Microimager 990 1 Select Duplex Front Location Mode Number 10 Mode Name MODE10 mA Mode Configuration H Image Management Code l Status MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvi Index Format Ftswitch Released Undef IMT Search Prg Number Supprs IA Display Format Ftswitch Cnf Tone Off Magnification 4233 IA Field Widths Patch Reader 1 Off Spice nefolion 2112 Level Rules Patch Reader 2 off epela E aati ge Polarity None Batching Patch Definition Lvl 2 i Auto AEC Mode Bar Code Off Duplex Front Location Duplex Film Mode Confirmation Tone NNN lt rips are os 27 Reduction Ratio OCR Status Off g
103. er 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Print Position Mode Number 10 Mode Name MODE10 Mode Configuration Endorser z 5 Status MODE 10 Mode Name Ftswitch Pressed Undef Mode 3 Lvl Index Format Ftswitch Released Undef Print Positi Supprs IA Display Format Ftswitch Cnf Tone Off rint Position 4233 IA Field Widths Patch Reader 1 O Previous Menu 2112 Level Rules Patch Reader 2 O None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Enter Print Position 0000 250 Save amp End Session Don t Save amp End Session Previous Menu End Configuration Range 0 00 5 0 00 2 Enter the desired print position within the allowable range for your machine type Microimager 70 0 to 70 inches or 0 to 1778 mm Scanner 900 0 to 20 inches or 0 to 500 mm Scanner 923 0 to 20 inches or 0 to 500 mm Scanner 9500 0 to 20 inches or 0 to 500 mm Scanner Microimager 990 0 to 20 inches or 0 to 500 mm Not Used This mode i
104. es to Indent is selected you must select the desired number of spaces No of Spaces 1 12 TO CHANGE Enter Value TO RETAIN Press Enter A 61097 May 1997 If Check Digit is selected the following window is displayed Item Line ONDAN 9 10 11 12 Document Printer 12 Print Template Print Item 1 01 lt IA No Del gt lt Message 1 gt Check Digit Mod 7A IA Only Mod 11A IA Only Mod 7B IA Only Mod 7B Full IA Mod 10 IA Only Mod 10 Full IA Mod 11B IA Only Mod 11B Full IA Custom IA Only Custom Full IA Previous Menu Previous Menu 3 Select the desired check digit calculation If an option that indicates A Only is chosen the level fields of the Image Address will be printed the Fixed Field will not be printed If an option which indicates Full IA is chosen the Fixed Field and Level fields of the Image Address will be printed NOTE If Custom IA Only or Custom Full IA is chosen the Check Digit options must be defined If Message Number is selected the following window is displayed Item Line ooN NAUN 10 11 12 Document Printer 12 Print Template Print Item 01 lt IA No Del gt lt Message 1 gt Previous Menu Previous Menu 1 Message Number Message Number 1 Message Number 2 Message Num
105. evel 2 Print Sequence Level 3 Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration m Examples of Formats Display 001 002 003 004 Compress 001 2 3 4 Suppress 001 2 3 4 Film Writer IA Format Display Leading Zeros Compress Leading Zeros Suppress Leading Zeros Previous Menu 2 Select the desired format option 3 25 Write Definitions This mode defines the information printed on film next to each document based upon the document level The default value for all levels is lt FF IA All Del gt WE Microimager 70 W Microimager 70 AFM LI Scanner 900 LJ Scanner 923 E Scanner Microimager 990 J Scanner 9500 When using a Microimager 70 without the Advanced Function Module installed a limited number of print items are available The available print items are e Full Image Address e Indexed Fields Only e Nothing Printed When using a Microimager 70 with the Advanced Function Module installed or Scanner Microimager 990 all print items may be used If the same information is to be printed next to documents of all levels 1 Select Same Sequence per Level fA FAN Write Sequence Current Print Sequence Display Values Full Image Address Indexed Fields Only Current Field Level Spaces between Items Current Day Current Date Current Time Document Counter New Print Sequence Displa
106. f Secondary DP 1 Off Doc Printer 12 Off Document Sorter Off Mode Overrides No Sav Film Definition F MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session Previous Menu Don t Save amp End Session End Configuration A 61097 May 1997 A 2 Mode Number 10 Mode Name MODE10 mA Mode to Mode Copy m Copy From Mode Copy Mode 1 Copy Mode 2 Copy Mode 3 Copy Mode 4 Copy Mode 5 Copy Mode 6 Copy Mode 7 Copy Mode 8 Copy Mode 9 Copy From Copy Mode 10 Mode Copy Mode 11 Copy Mode 12 Copy Mode 13 Copy Mode 14 Copy Mode 15 Copy Mode 16 Copy Mode 17 Copy Mode 18 Previous Menu Select Mode to Copy From Mode Number 10 Mode Name MODE10 mA Mode to Mode Copy m Copy From Mode Copy Mode 1 _ gt Copy Mode 2 gt Copy Mode 3 gt Copy Mode 4 _ gt Copy Mode 5 _ gt Copy Mode 6 j Copy Mode 7 gt Copy Mode 8 gt Copy Mode 9 _ gt Copy From Copy Mode 10 _ gt Mode Copy Mode 11 _ gt Copy Mode 12 gt 01 Copy Mode 13 gt Copy Mode 14 _ gt Co
107. f 9 Code 39 2 of 5 Interleaved 2 of 5 CODA Codabar Number of 03 80 Characters Codes per ONE ALL Document Distance Between 0 375 3 000 in Codes 09 53 76 20 mm Scan Direction UNI Uni directional BI Bi directional Image Processing ON Enabled OFF Disabled Partial Read ON Enabled OFF Disabled Minimum Partial 03 80 Read Characters 41 10 Patch Reading ON Enabled OFF Disabled Patch Location 1 92 9 60 in 048 77 243 84 mm A 61097 May 1997 Tem Description vanes 41 12 End Fed Patch 41 13 Level Change Confirmation Tones Patch Detected Bar Code Detected Bar Code Patch Detected ee OCR Status COIN User Channel Transmit Data Print Controller Image Address Print Format Print Position Special Character Set Primary Document Printer 1 Status Font Orientation Print Definitions Secondary Document Printer 1 Status Font Orientation ON Enabled OFF Disabled Level 0 Level 1 Level 2 Level 3 OFF Undefined ON Enabled OFF Disabled ON Enabled ney Disabled NO Not used YES Used Enter data DISP Display COMP Compress SUPP Suppress 00 125 75 000 in 3 1778 mm SM Smaller font LG Larger font ON Enabled OFF Disabled SCOM Sm Comic SCIN Sm Cine SCOM180 Sm Comic180 SCIN180 Sm Cine180 LCOM Lg Comic LCIN Lg Cine LOM180 Lg Comic 180 LCIN180 Lg Cine 180 E
108. f Tone O 4288 IA Field Widths Patch Reader 1 Ol Press ENTER to proceed 2112 Level Rules Patch Reader 2 Oi None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Oi Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Oi 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Oi Off Length Monitor Secondary DP 1 Oi Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Oi Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration This mode enables or disables mode overrides Enabling this option means that permanent changes may be made to the original mode option definitions using select function codes during operation Disabling this option means that changes made to the original mode option definitions using select function codes during operation are temporary The default value is Discard Overrides E Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Mode Overrides Mode Number 10 Mode Name MODE10 Mode Configuration Overrides m MODE 10 Mode Name Ftswitch Pressed Undef Discard Overrides 3 Lvi Index Format Ftswitch Released Undef Save Overrides Supprs IA Display Format Ftswitch Cnf Tone Ofi 7 4233 IA Field Widt
109. fault values apply only to the Scanner Microimager 990 pP Key Definition P1 f04 2 Count only toggle P2 f45 Print test P3 f09 Total document count P4 f08 Last Image Address P5 f37 Calibrate P6 f30 Amount of film remaining P7 f44 Omit printing on next document only P8 f46 Print position P9 f07 LevelO P10 f98f38Stop End of Job To enter a function code type an f lower case followed by a two digit code i e 04 Any additional information such as a zero 0 to disable a function a one 1 to enable a function or a two 2 to toggle a function is entered by typing a comma followed by the additional information i e 04 7 enables counting only Multiple function codes are entered as a string of individual function codes with no spaces or delimiters in between i e 98 38 stops the machine and then issues an end of job indicator When using a Microimager 70 without the Advanced Function Module installed only two of the P Keys are programmable P5 and P10 When using a Microimager 70 with the Advanced Function Module installed Scanner 900 Scanner 923 Scanner Microimager 990 or Scanner 9500 all P Keys are programmable P Keys are programmed using the following sequence of steps 1 Select a P Key P1 P10 2 Press Return Enter 3 Enter the desired function Repeat this sequence for
110. ff or Disabled WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Status Mode Number 10 Mode Name MODE10 Mode Configuration Endorser z f Status MODE 10 Mode Name Ftswitch Pressed Undef Mode 3 Lvl ndex Format Ftswitch Released Undef Print Positi Supprs IA Display Format Ftswitch Cnf Tone 0 rint Position 4233 A Field Widths Patch Reader 1 O Previous Menu 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 Ofi Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Oi Off Endorser Mode Overrides No Sav Not Used Film Definition F Endorser Status Off or Disabled Save amp End Session Don t Save amp End Session On or Enabled Previous Menu End Configuration Previous Menu 2 Select the desired status NOTE If Off or Disabled is selected definitions for the remaining options will be ignored 3 48 A 61097 May 1997 Endorser Mode This mode defines whether the endorser will print continually or only once per document Continuous will activate the Endorser continu
111. ge Enter Value To Retain Press Enter Custom Check Digit Configuration Help Attributes These are position weights for digit in the IA A zero value attribute causes the associated IA digit to be excluded from the check digit calculation Each digit in the IA is multiplied by its attribute and summed Constant 1 A constant in the range 00 99 Constant 2 A constant in the range 00 99 A constant in the range 00 99 Not used if value is zero Left Right Indicates the location of the check digit in relation to the decimal point in the calculation results If left is specified the check digit is immediately to the left of the decimal point and vice versa LUT Status If Yes the final check digit calculated is used as an index into a lookup table If No the lookup table is ignored Lookup Table A table of check digit values A 61097 May 1997 2 37 Ol Hardware Character Set 2 38 This option defines non English character sets which may be used by the Operator Interface Document Printers and the Film Writer English characters are contained in both sets The default Ol character set is Anglo Japanese LJ Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select OI Hardware Character Set 2 Enter the desired printer font option E Scanner 900 E Scanner 9500 NOTE The proper hardware display module must be installed Display Machine Accessories Machine ID
112. ghlighted Identify the line numbers which correspond to the area s of the customer document where you want the printed information to appear Use these line numbers when defining the print template s NOTE The placement of printed information will vary slightly due to a number of factors including document transport speed Expect a variation of 0 125 inch between the print template and starting print position definitions and the location of actual printed information 2 18 A 61097 May 1997 Dotted line Starting print position distance from the leading edge of the document Tn mes J mes J O o mea J O o mes J o mes J o mez O O mes meos J O o Tne men J o me J me O men O o A mes O O me J O O mes J o me J O o me mea J O o me J me J Z o mea o mes o mes o mez o me o me J Z o meso J O o mes O o mes o mess O o mes O o mess O o mess O o Inea C 5 5 lines per inch Vertical placement on the document is dependent upon the position of the Document Printer 12 in the transport plate A 61097 May 1997 2 19 Dotted line Starting print position distance from the leading edge of the document Line 1 Lines lines bnet Liners line2o Lines Lne25 4 lines per inch Vertical placement on the document is dependent upon the position of the
113. grammable Function Keys gt MACHINE STATE E Scanner 9500 2 40 A 61097 May 1997 3 Selecting the Mode Configuration Window This section lists the Mode Definitions for the Scanner Microimager Follow these steps to select the Mode Definition screen m Mainframe Configuration m MACHINE STATE Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session 1 Select Mode Configuration The following window will be displayed Mode Configuration i Define Mode 1 Define Mode 2 Define Mode 3 Define Mode 4 Define Mode 5 Define Mode 6 Define Mode 7 Define Mode 8 Define Mode 9 Define Mode 10 Define Mode 11 Define Mode 12 Define Mode 13 Define Mode 14 Define Mode 15 Define Mode 16 Define Mode 17 Define Mode 18 Mode to Mode Copy End Session Previous Menu A 61097 May 1997 2 Select a mode to be defined The Mode Configuration window will be displayed with the Mode Number you selected for definition displayed at the top
114. grammable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writ Please confirm ending session DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Prot Custom Check Digit End Session Ol Hardware Charac Save Configuration t Load Configuration from PC Mode Configuration Continue Session End Session 3 Select End Session to exit to DOS or Continue Session if you do not want to exit at this time A 61097 May 1997 1 9 2 Machine Definitions The following section lists the items on the Mainframe Configuration Menu that may be selected for definition m Mainframe Configuration L Display Machine Accessories MACHINE STATE Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session The following list appears for each option A black square indicates that the option is available on that machine A white square indicates that the option is not available on that machine An example is illustrated below WE Microimager 70 d Mi
115. guration key which indicates whether or not the option is available for each machine configuration If you attempt to define an option which is not valid under your machine configuration you will receive a message which indicates that the option is not available Simply press the Return Enter key to continue Follow the Installation Instructions in order to define all of the available options recording each definition on the Installation Questionnaire form found in chapter 4 The Installation Questionnaire form requires that you write your selections in the space provided Due to space limitations Appendix C Recommended Questionnaire Entries contains recommended shorthand entries for the various options you may enter This is provided so that there is consistency among users making it easier for other users to decipher your selections 1 8 A 61097 May 1997 Logout Procedure Once you have completed the installation the following sequence of steps may be used to log out of the system From the Mode Configuration window 1 Select Save amp End Session if you wish to save all of the definitions or Don t Save amp End Session if you do not wish to save all of the definitions You will be returned to the Configuration window 2 Select End Session from the Configuration window m Mainframe Configuration m MACHINE STATE Display Machine Accessories Machine ID Number Display Language Measurement System Pro
116. hing Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration This mode enables or disables the primary Document Printer 1 The default value is Off or Disabled W Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Document Printer Status E Scanner 900 E Scanner 9500 Primary Document Printer Document Printer Status Fonts Orientation Same Format per Level Print Sequence Level 0 Print Sequence Level 1 Print Sequence Level 2 Print Sequence Level 3 Previous Menu Mode Number 10 Mode Name MODE10 Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone O 4233 IA Field Widths Patch Reader 1 Ofi 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Of Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Oi 1 Roll
117. hs Patch Reader 1 Of Previous Menu 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Of Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Of Xport Check Stacker Document Sorter Of Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 2 Select the desired override option 3 102 A 61097 May 1997 Film Definition This mode enables or disables filming This option is set as follows Microimager 70 F film Scanners 900 923 9500 NoF no film Scanner Microimager 990 F film LJ Scanner 900 L Microimager 70 L Scanner 923 LJ Microimager 70 AFM E Scanner Microimager 990 LJ Scanner 9500 Mode Number 10 Mode Name MODE10 m Mode Configuration t MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone O 4233 IA Field Widths Patch Reader 1 O 2112 Level Rules Patch Reader 2 O None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 R
118. i E i a Level 3 Level 2 Level 1 Level 3 Whenever a large image mark is placed next to a document and or a document is assigned Level 3 the Image Address field associated with Level 3 Field C is incremented and the fields associated with Level 2 Field B and Level 1 Field A are set to zero Whenever a medium image mark is placed next to a document and or a document is assigned Level 2 the Image Address Field associated with Level 3 Field C is unchanged the field associated with Level 2 Field B is incremented and the field associated with Level 1 Field A is set to zero Whenever a small image mark is placed next to a document and or a document is assigned Level 1 the Image Address fields associated with Level 3 Field C and Level 2 Field B are unchanged and the field associated with Level 1 Field A is incremented Three Level Offset E E a E a E E j E E i Level 3 Level 2 Level 1 Level 3 Whenever a large image mark is placed next to a document and or a document is assigned Level 3 the Image Address field associated with Level 3 Field C is incremented and the field associated with Level 2 Field B is set to zero Whenever a medium image mark is placed next to a document and or a document is assigned Level 2 the Image Address field associated with Level 3 Field C is unchanged and the field associated with Level 2 Field B is incremented Whenever a small image mark is placed next to a document
119. idths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session Previous Menu Don t Save amp End Session End Configuration Level 0 Level 1 Level 2 Level 3 Previous Menu 3 Select the level to follow the specified level A 61097 May 1997 3 13 Batching Batch Level This mode defines the number of documents of a specified level to process prior to performing a predefined action W Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Batching E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 m Mode Configuration Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 Off Patch Reader 2 f Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition EQ N aS z B lt oR RR RGSS mMZOQQQ0000ZO n w wE Batching Batch Level Batch Value Start of Batch Function End of Batch Function Previous Menu MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batchi
120. ilm Definition F Patch 1 Status Off or Disabled Save amp End Session Don t Save amp End Session On or Enabled Previous Menu End Configuration Previous Menu 2 Select the desired status NOTE IF Off or Disabled is selected the definitions for the remaining patch options will be ignored If you have a unit with Document Scanning Array DSA and you choose Patch Reader 1 you will get the message Patch Reader 1 the accessory that you requested is not installed This is due to the fact that Patch Reading must be set up under barcode if you have a DSA 3 54 A 61097 May 1997 Patch Reader 2 NOTE A Patch Reader accessories or Document Scanning Array must be installed Enables or disables the secondary patch reader The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Patch Reader 2 LJ Scanner Microimager 990 E Scanner 900 E Scanner 9500 MODE 10 3 Lvl Supprs 4233 2112 None Auto Mode Number 10 Mode Configuration t Mode Name Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Name MODE10 Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR S
121. irmation Tone NNN 27 Reduction Ratio OCR Status Of l ot bo 1 Roll of Cassettes COIN User Channel On m Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O m Off Length Monitor Secondary DP 1 O me D Off Skew Monitor Doc Printer 12 Ofi SEE Xport Check Stacker Document Sorter Off L Off Endorser Mode Overrides No Sav 50X Not Used Film Definition F 40X 50X 50X 24X 40X 40X Save amp End Session Don t Save amp End Session Previous Menu End Configuration 2 Select the desired film mode NOTE If you intend to link the current mode with another mode the film mode chosen for both modes must be compatible Simplex mode is compatible with either simplex mode or duplex mode Duplex mode is compatible with either simplex mode or duplex mode Duo mode is compatible only with duo mode NOTE Film mode is not available on the scanners A 61097 May 1997 3 19 e Simplex Mode Simplex format allows one image to be exposed across the film width A 24 1 reduction ratio is used for this format e Duplex Mode Duplex format allows front and back images of the same document to be exposed at the same time across the film width A 40 1 or 50 1 reduction ratio is used for this format Lead End CT ef afr O Dupes symb fon contd panel daplayh C HEN Dupe e Duo Mode Duo format allows documents to be filmed across one half of the film width
122. l IA w No Delimiters Full IA w FF Delimiter Full IA w All Delimiter Fixed Field Only Indexed Fields Only Current Field Level Spaces between Items Current Day Current Date Current Time Document Counter Roll Number Message 1 9 Check Digit Nothing Printed Previous Menu 2 Select the item s to be printed in turn up to a maximum of thirty eight 38 characters including spaces NOTE If the definition exceeds the thirty eight 38 character limit the first thirty eight 38 characters will be printed on each document and the remainder of the information will be truncated If Soaces between Items is selected you must select the desired number of spaces A 61097 May 1997 3 93 If Check Digit is selected the following window is displayed Check Digit Mod 7A IA Only Mod 11A IA Only Mod 7B IA Only Mod 7B Full IA Current Print Sequence Display Values Mod 10 IA Only Mod 10 Full IA Mod 11B 1A Only New Print Sequence Display Values Mod 11B Full IA Custom IA Only Custom Full IA Previous Menu 3 Select the desired check digit calculation If an option which indicates A Only is chosen the level fields of the Image Address will be printed the Fixed Field will not be printed If an option which indicates Full IA is chosen the Fixed Field and level fields of the Image Address will be printed NOTE If Customer IA Only o
123. l rules for Mode 8 and Mode 9 may be defined the level rules are predefined and unalterable in Mode 1 Mode 7 The predefined values are e Mode 1 Level 0 followed by Level 1 Level 1 followed by Level 1 Level 2 followed by no level Level 3 followed by no level e Mode 2 Level 0 followed by Level 2 Level 1 followed by Level 1 Level 2 followed by Level 2 Level 3 followed by no level e Mode 3 Level 0 followed by Level 2 Level 1 followed by Level 1 Level 2 followed by Level 2 Level 3 followed by no level e Mode 4 Level 0 followed by Level 3 Level 1 followed by Level 1 Level 2 followed by Level 2 Level 3 followed by Level 2 e Mode 5 Level 0 followed by Level 2 Level 1 followed by Level 1 Level 2 followed by Level 1 Level 3 followed by Level 2 e Mode 6 Level 0 followed by Level 2 Level 1 followed by Level 2 Level 2 followed by no level Level 3 followed by no level e Mode 7 Level 0 followed by Level 2 Level 1 followed by Level 2 Level 2 followed by Level 2 Level 3 followed by no level When using a Microimager with the Advanced Function Module installed Scanner 900 Scanner 923 Scanner 9500 or Scanner Microimager 990 the level rules for all modes may be defined 3 12 A 61097 May 1997 1 Select Level Rules Mode Number 10 Mode Configuration Mode Name MODE10 Field Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch
124. ll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration Secondary DP 1 Off or Disabled On or Enabled Previous Menu 2 Select the desired status A 61097 May 1997 3 91 Fonts Orientation DP2 This mode defines the size and orientation of the characters printed by the secondary Document Printer 1 The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Fonts Orientation E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 MODE 10 3 Lvl Supprs 4233 2112 None Auto Mode Name Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Configuration Second Document Printer Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Of Patch Reader 1 Off Patch Reader 2 Oi Patch Definition Lvl 2 Bar Code Off Confirmation Tone NNN OCR Status O COIN User Channel On
125. lt values are displayed in the Key Definition table The following values apply only to the Scanner 9500 r Key Definition Pi 37 Calibrate P2 f98f38 Stop End of Job P3 01 01 Change to Mode 1 P4 01 02 Change to Mode 2 P5 f01 03 Change to Mode 3 P6 01 04 Change to Mode 4 P7 01 05 Change to Mode 5 P8 01 06 Change to Mode 6 P9 01 07 Change to Mode 7 P10 f01 08 Change to Mode 8 Prev Previous Menu The following values apply only to the Microimager 70 and Microimager 70 AFM rt Key m Definition p Pi 04 2 Count only toggle P2 45 Print test P3 f09 Total document count P4 08 Last Image Address P5 33 Roll number P6 f30 Amount of film remaining P7 44 Omit printing on next document only P8 46 Print position PQ 07 Level 0 P10 35 Cassette ID number The following default values apply only to the Scanner 900 923 rt Key Definition p Pi 37 Calibrate P2 f98f38 Stop End of Job P3 f01 01 Change to Mode 1 P4 f01 02 Change to Mode 2 P5 f01 03 Change to Mode 3 P6 f01 04 Change to Mode 4 P7 f01 05 Change to Mode 5 P8 f01 06 Change to Mode 6 P9 f01 07 Change to Mode 7 P10 ff01 08 Change to Mode 8 A 61097 May 1997 2 7 The following de
126. n Don t Save amp End Session Cine 180 Previous Menu End Configuration Previous Menu 2 Select the desired orientation D C a T im l ee A 2 7 i z N Go a 3 24 A 61097 May 1997 Image Address Print Format A 61097 May 1997 This mode defines the format of the Image Address printed on film The default is Compress 1 L Scanner 923 L Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 Select Image Addr Print Format LJ Scanner 900 LJ Scanner 9500 Mode Number 10 mA Mode Configuration MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Advanced Film Writer Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 O Patch Reader 2 Ofi Patch Definition Lvl 2 Bar Code O Confirmation Tone NNN OCR Status Oi COIN User Channel On Printer Control Disply Primary DP 1 O Secondary DP 1 Ofi Doc Printer 12 Off Document Sorter Oi Mode Overrides No Sav Film Definition Character Orientation Image Addr Print Format Same Sequence per Level Print Sequence Level 0 Print Sequence Level 1 Print Sequence L
127. n ponge e Sree Code 2 Enter the desired magnification level within the range 0 or 20 80 3 31 Splice Definition This mode defines the desired action when a splice is detected The default value is gnore WE Microimager 70 W Microimager 70 AFM LJ Scanner 923 E Scanner Microimager 990 1 Select Splice Definition L Scanner 900 LJ Scanner 9500 Select any of the Sort Criteria and the following screen appears Image Management Code Status IMT Search Prg Number Magnification Splice Definition Image Mark Sizes Image Polarity Mode Number 10 Mode Name MODE10 mA Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone O 4233 IA Field Widths Patch Reader 1 Off 2112 Level Rules Patch Reader 2 O None Batching Patch Definition Lv Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter O Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration Duplex Front Location Film Image Orientation Image Offset Previous Men
128. ng Ftswitch Pressed Undef ea ei Maes oe aia Start of Batch Function Patch Reader 1 0 End of Batch Function Patch Reader 2 O Previous Menu Patch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status O COIN User Channel On Printer Control Disply Primary DP 1 Of Secondary DP 1 O Doc Printer 12 Ofi Document Sorter O Mode Overrides No Sav Film Definition F End of Batch Function Save amp End Session Previous Menu Don t Save amp End Session End Configuration Enter the function s to be performed after batch processing 194 f95 196 198 go to Level 1 go to Level 2 go to Level 3 Stop A 61097 May 1997 3 17 AEC Mode This mode enables or disables Automatic Exposure Control Fixed Mode disables Automatic Exposure Control Auto Mode enables Automatic Exposure Control The default value is Auto Mode WE Microimager 70 W Microimager 70 AFM LJ Scanner 923 1 Select AEC Mode E Scanner Microimager 990 LJ Scanner 900 LJ Scanner 9500 Mode Number 10 MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Configuration Mode Name MODE10 AEC Status
129. ng Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session Previous Menu Don t Save amp End Session End Configuration This mode defines the level of the documents to be counted The default value is None W Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Batch Level E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 Mode Configuration Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch Reader 1 Oi Patch Reader 2 O Patch Definition Lvl 2 Bar Code Oi Confirmation Tone NNN OCR Status Of COIN User Channel On Printer Control Disply Primary DP 1 Oi Secondary DP 1 O Doc Printer 12 O Document Sorter Off Mode Overrides No Sav Film Definition F Batching Batch Level Batch Value Start of Batch Function End of Batch Function Previous Menu MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session
130. nition F Save amp End Session Previous Menu Don t Save amp End Session End Configuration IA Print Format Print Position Special Character Set Previous Menu m Examples of Formats Display 001 002 003 004 Compress 001 2 3 4 Suppress 1 2 3 4 m DP IA Display Format Display Leading Zeroes Compress Leading Zeroes Suppress Leading Zeroes Previous Menu 2 Select the desired print format A 61097 May 1997 Print Position This mode defines how far from the leading edge of the document s the information printed by the document printer s will appear The default value is 00 250 inch 6 25 mm WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Print Position Mode Number 10 Mode Name MODE10 Mode Configuration Printer Control E MODE 10 Mode Name Ftswitch Pressed Undef IA Print Format 3 Lvi Index Format Ftswitch Released Undef Print Position Supprs 1A Display Format Ftswitch Cnf Tone Off Special Character Set 4233 IA Field Widths Patch Reader 1 Off Previous Menu 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off
131. nition Lvi 2 mage Processing Auto AEC Mode Bar Code Off Partial Read Enabled Duplex Film Mode Confirmation Tone NNN Min Partial Characters 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On DSA Patch Reading Status Comic Film Writer Printer Control Disply Patch Horizontal Location Off Image Mgmt Code Primary DP 1 Off End Fed Patch Read Status Off Length Monitor Secondary DP 1 Off Level Change via Bar Code Off Skew Monitor Doc Printer 12 Off Previous Menu Xport Check Stacker Document Sorter Off Patch Level Off Endorser Mode Overrides No Sav L TE EVE Not Used Film Definition F ever Level 1 Level 2 Save amp End Session Don t Save amp End Session Level 3 Previous Menu End Configuration Undefined Previous Menu 2 Select the desired level to be assigned when a bar code is detected NOTE It is recommended that patch codes rather than bar codes be used to perform document level changes Using patch codes to alter document image levels is much more reliable and accurate than the use of bar codes to alter document image levels The lower reliability level which may be experienced using bar codes to alter document image levels may have serious ramifications depending upon the application It is suggested that you contact Marketing Support in Rochester if you wish to implement this feature A 61097 May 1997 3 73 Confirmation Tones NOTE The tones must have been enabled du
132. nt Reset Level Counts Allows you to reset all counters Level 0 Level 1 Level 2 Level 3 and Total to zero Alarm Tone Allows you to adjust the pitch of the alarm tone Elapsed Time Allows you to display the number of hours the motor transport and AC have been running in addition to the non resettable document count Display Contrast Allows you to adjust the contrast of the Status Display Display Language Allows you to choose the language in which the Status Display messages will appear Measurement System Allows you to choose the measurement system in which measurements are displayed F21 Change Time Allows you to change the time F22 Change Date f Allows you to change the date F23t Time and Date Display f Allows you to view the current time and date F24 AEC On Off off disabled Allows you to turn the Automatic Exposure Control on on enabled or off AEC Auto Adjust Allows you to adjust the AEC exposure setting when the AEC is in Auto Mode ON t May be executed while transport is running Available when filming for use only with Microimager 70 with or without AFM and Scanner Microimager 990 Available when scanning for use only with the Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 Available when using advanced capabilities for use only with the Microimager 70 with AFM Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990
133. nter item s ON Enabled OFF Disabled SCOM Sm Comic SCIN Sm Cine SCOM180 Sm Comic 180 SCIN180 Sm Cine180 LCOM Lg Comic LCIN Lg Cine LCOM180 Lg Comic180 LCIN180 Lg Cine180 C 3 iem Description Values Print Definitions Enter item s Document Printer 12 Status ON Enabled OFF Disabled Font Orientation COM Comic COM180 Comic 180 Print Definitions Enter template Document Sorter Status ON Enabled OFF Disabled Error Response DISP Display BEEP Display and Beep Stop Stop and Display Sort Criteria Enter selected criteria and bin 50 0 Mode Overrides DIS Discard SAV Save 51 0 Film Definition Filming Enabled Filming Disabled C 4 A 61097 May 1997 A 61097 5 97 Eastman Kodak Company 1997 Printed in U S A EASTMAN KODAK COMPANY Business Imaging Systems Rochester New York 14650 Kodak Digital Science the ds monogram symbol and Imagelink are trademarks of Eastman Kodak Company Printed on recycled paper BUSINESS IMAGING KS SYSTEMS
134. nu 2 Select the desired status NOTE If Off or Disabled is selected definitions for the remaining options will be ignored A 61097 May 1997 3 43 Skew Threshold This mode defines the amount of tolerable skew If 5 Degrees is selected an error will be reported if the amount of document skew is between 5 and 30 degrees If 10 Degrees is selected an error will be reported if the amount of document skew is between 10 and 30 degrees Regardless of the option selected if the amount of document skew is greater than 30 degrees no error will be reported The default value is 10 Degrees WE Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Skew Threshold E Scanner 900 E Scanner 9500 A Skew Monitor Skew Detect Status Skew Threshold Skew Error Response Previous Menu Skew Threshold Mode Number 10 Mode Name MODE10 mA Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone Off 4233 IA Field Widths Patch Reader 1 Oi 2112 Level Rules Patch Reader 2 O None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code Oi Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monito
135. oc Printer 12 Document Sorter Mode Overrides Film Definition lt 12 f NN 5 sply e90000Z90 EJ gQ No Sav F Save amp End Session Previous Menu Don t Save amp End Session End Configuration H Second Document Printer Document Printer Status Fonts Orientation Same Format per Level Print Sequence Level 0 Print Sequence Level 1 Print Sequence Level 2 Print Sequence Level 3 Previous Menu 3 90 A 61097 May 1997 Document Printer Status Enables or disables the secondary Document Printer 1 The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Document Printer Status E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Fonts Orientation Same Format per Level Second Document Printer Document Printer Status Print Sequence Level 0 Print Sequence Level 1 Print Sequence Level 2 Print Sequence Level 3 Previous Menu Mode Number 10 Mode Name MODE10 m Mode Configuration t MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone Off 4233 IA Field Widths Patch Reader 1 Off 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Ro
136. ocument until it is redefined Select Linked Mode Allows you to switch from one application mode to another keeping the last Image Address Fixed Field Allows you to enter a new fixed field value containing alphanumeric characters F93 Action Confirmation Tone Allows you to adjust the pitch of the action confirmation tone F94t Level 1 Allows you to assign Level 1 to the next document fed into the transport F95t Level 2 Allows you to assign Level 2 to the next document fed into the transport F96t Level 3 Allows you to assign Level 3 to the next document fed into the transport F97 Next Image Address Allows you to input the next Image Address F98t Stop Allows you to stop the transport Run f Allows you to turn on the transport f76 f80 f81 f82 f91 f92 f93 f94 f95 f96 f97 f98 99 t May be executed while transport is running Available when filming for use only with Microimager 70 with or without AFM and Scanner Microimager 990 Available when scanning for use only with the Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 Available when using advanced capabilities for use only with the Microimager 70 with AFM Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 Available when using advanced capabilities for use only with the Microimager 70 with AFM Scanner 900 Scanner 923 and Scanner Microimager 990 B 6 A 61097 May 1997 APPENDIX C
137. ogrammable Function Keys Print Template 1 Date Format Print Template 2 Time Format Print Template 3 Alarm Tone Print Template 4 Doc Printer Film Writer Msg Print Template 5 DP 12 Print Template Print Template 6 Fixed Field Delimiter Print Template 7 Set System Clock Print Template 8 Version Numbers Print Template 9 User COIN Port Protocol Print Template 10 Custom Check Digit Previous Menu Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session A 61097 May 1997 2 15 1 Follow these steps for each line item to be printed maximum twelve per template a Select the next available item number or Item 1 if this is the first item b Enter a line number corresponding to the line number on the print template master c Select one or more of the print items listed maximum three items per line NOTE Anything over 12 characters will be truncated Document Printer 12 Print Template Print Items Item Line Print Item Full IA w No Delimiter 1 01 lt IA No Del gt Full IA w FF Delimiter Fixed Field Only 2 Indexed Fields Only 3 Current Field Level 4 Number of Spaces to Indent 5 Current Day 6 Current Date 7 Current Time 8 Roll Number 9 Total Document Count Message 1 9 10 Check Digit H Nothing Printed Previous Menu Previous Menu If Number Spac
138. oll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 Of Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Ofi Off Endorser Mode Overrides No Sav Not Used Film Definition E Filming Definition in Filming Enabled Save amp End Session Don t Save amp End Session Filming Disabled Previous Menu End Configuration Previous Menu A 61097 May 1997 3 103 4 Installation Questionnaire General Information CUSTOMER NAME CUSTOMER ADDRESS CUSTOMER CONTACT PHONE SALES REPRESENTATIVE PHONE TRAINER PHONE MACHINE ID NUMBER MODE NUMBER NAME APPLICATION S i o Aa N O oO A WO D o 11 12 13 14 15 16 17 18 A 61097 May 1997 Machine Definitions 0 0 Accessory Status Adv Doc Controller Bar Code Reader Doc Scanning Array Check Feeder Check Stacker Document Sorter Endorser Footswitch Film Writing Module Image Marker Patch Reader 1 Patch Reader 2 Print Controller Primary Doc Printer 1 Secondary Doc Printer 1 Doc Printer 12 OCR 1 0 Machine ID Number 2 0 Display Language 3 0 Measurement System 4 0 Programmable Function Keys P Key Definition P1 P2 P3 P4 P5 P6 P7 P8 P9 P10
139. om Check Digit Definition Custom Check Digit Formula Check Digit Constant 2 Sum of IA Digits Attributes Constant 1 Divisor Parameter Current Value Attributes 46231546231 Constant 1 00 Constant 2 00 Divisor 07 Left Right Right LUT Status No Enter constant 2 Lookup Table abcdefghijk Req d entry 2 digits Help 00 Previous Menu To Change Enter Value To Retain Press Enter 7 Select the Divisor parameter for definition 8 Enter a value between 00 99 Custom Check Digit Definition Check Digit Constant 2 Custom Check Digit Formula Sum of IA Digits Attributes Constant 1 Divisor Parameter Current Value Attributes 46231546231 Constant 1 Constant 2 00 Divisor 07 Left Right Right LUT Status No Enter divisor Lookup Table abcdefghijk Req d entry 2 digits Help 07 Previous Menu To Change Enter Value To Retain Press Enter A 61097 May 1997 2 35 9 Select the Left Right parameter for definition 10 Select the digit to be used during calculation of the check digit Custom Check Digit Definition Custom Check Digit Formula Check Digit Constant 2 Sum of IA Digits Attributes Constant 1 Divisor Parameter Current Value Attributes Constant 1 Constant 2
140. on Module installed all of the print templates defined during machine configuration are available for selection 2 Select the print template which contains the information to be printed on all documents 3 Select Print Sequence Level for the desired level Mode Number 10 Mode Name MODE10 Mode Configuration Document Printer 12 MODE 10 Mode Name Ftswitch Pressed Undef Sues Status 3 Lvl Index Format Ftswitch Released Undef S F t tavai Supprs IA Display Format Ftswitch Cnf Tone Off Print S orma pre at 0 4233 IA Field Widths Patch Reader 1 Off Bante caicnes s Eesaid 2112 Level Rules Patch Reader 2 off print Sequence level 2 None Batching Patch Definition Lvi 2 Print S Level 3 Auto AEC Mode Bar Code Off HL SeQente SEVR Duplex Film Mode Confirmation Tone NNN Previous Menu 22222 Reduction Ratio OCR Status Off Print Level gt 1 Roll of Cassettes COIN User Channel On Print Template 1 Comic Film Writer Printer Control Disply Print T late 2 Off Image Mgmt Code Primary DP 1 Off as ite Off Length Monitor Secondary DP 1 Off Prin Template 4 Off Skew Monitor Doc Printer 12 Off Print Template 5 Xport Check Stacker Document Sorter Off Print Template 6 Off Endorser Mode Overrides No Sav rint Template Pen Print Template 7 Not Used Film Definition F Print Template 8 Print Template 9 Save amp End Session Don t Save amp End Session Print Template 10 Previous Menu End Configuration No Print
141. one Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Start of Batch Function Save amp End Session Don t Save amp End Session Previous Menu End Configuration 2 Enter the function s to be performed prior to batch processing Valid Start of Batch functions are f94 go to Level 1 f95 go to Level 2 f96 go to Level 3 3 16 A 61097 May 1997 End of Batch Function This mode defines the action s to be taken after processing the document in the batch The default value is 98 Stop LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select End of Batch Function E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 3 Lvl Supprs 4233 2112 None Auto Duplex Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Configuration MODE 10 Mode Name Mode Name MODE10 Batchi
142. ool number TL 4219 Available through Businessland using part number 984956 A 61097 May 1997 1 1 Software Installation Procedure Follow these steps to install the software 1 2 Insert the Mode Setup Software diskette into the drive Type A INSTALL next to the DOS prompt and press Return Enter If the disk drive on your unit is not designated as the A drive substitute the correct drive designation in this command string Microimager IL70 IL70 AFM Scanner IL900 IL923 Microimager Scanner DS990 Scanner DS9500 Mode Setup Software Copyright c 1989 1997 Eastman Kodak Company All Rights Reserved Press Any Key to Install ESCAPE to Exit 3 Press any key Mode Setup Software Directory Information Drive To Install From A Drive To Install To C Directory To Be Installed To SETUP ESCAPE to Abort A 61097 May 1997 4 Enter the desired drive and directory designations and press Enter Directory Information Drive To Install From A Drive To Install To C Directory To Be Installed To SETUP ESCAPE to Abort Press ENTER to Accept any other key to Edit 5 Press Enter to continue the logon procedure Press any other key to alter the drive and directory designations Mode Setup Software Please Wait While Files Are Being Copied To Your Destination Drive Use Existing Directory Y N Hit NJo
143. osition the highlight cursor over the Previous Menu option or press the PAGEDOWN key to automatically position the highlight cursor over the Previous Menu option Press the Return Enter key If you receive a message indicating that an accessory is not installed press the Return Enter key to continue This message indicates that the option selected requires an accessory which is not physically installed and or properly defined to the software In either instance contact your Kodak service representative to properly install and or define the accessory If you receive a message that indicates a selection is not available press the Return Enter key to continue This message indicates that the option selected is not available in the mode selected or is not available for the machine configuration Using the Mode Setup Software Questionnaire and Instructions There are two pieces of documentation designed for use with the Mode Setup Software the Installation Instructions which provide information on how to install access and use the software to define the available options and the Installation Questionnaire which provides a convenient form on which to record all of the machine and mode definitions The Installation Instructions describe all of the available options which can be defined using the Mode Setup Software NOTE Not all options are available using a given machine configuration Hence each definition is accompanied by a confi
144. py Mode 15 _ gt Copy Mode 16 gt Copy Mode 17 os e Copy Mode 18 _ gt Previous Menu Copy To Mode Copy Mode 1 Copy Mode 2 Copy Mode 3 Copy Mode 4 Copy Mode 5 Copy Mode 6 Copy Mode 7 Copy Mode 8 Copy Mode 9 Copy Mode 10 Copy Mode 11 Copy Mode 12 Copy Mode 13 Copy Mode 14 Copy Mode 15 Copy Mode 16 Copy Mode 17 Copy Mode 18 Previous Menu Select Copy to Mode 2 Mode Number 10 Mode Name MODE10 Mode to Mode Copy Are you sure you want to Copy From do this Mode a ao All data in 01 the copied mode will be lost Previous Menu Copy to Mode Copy To Mode 02 Select Copy to Mode Downloading Mode Configuration Mainframe Send Mode Configuration to Mainframe A 61097 May 1997 APPENDIX B Function Codes P Key Definition Input Function Code Name Description Required Optional Select Mode xx 2 digit mode number Allows you to select one of the eighteen 18 application modes Restore Mode Allows you to restore the current application mode to its default status as it was defined at installation provided that mode overrides are not saved Filming Only off disable Allows you to film documents with no level counting on enable endorsing patch reading etc toggle Counting Only off disable Allows you to count documents only with no filming on ena
145. r Not Used Mode Configuration MODE 10 Mode Name Mode Name MODE10 Document Printer 12 Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef Of Of Of Lvl 2 Document Printer Status Fonts Orientation Same Format per Level Print Sequence Level 0 Print Sequence Level 1 Print Sequence Level 2 Print Sequence Level 3 Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration m PAW 12 Status Off or Disabled On or Enabled Previous Menu 2 Select the desired status A 61097 May 1997 3 97 Fonts Orientation DP12 This mode defines the size and orientation of the characters printed by the Document Printer 12 The default value is Comic Orientation W Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 E Scanner 900 E Scanner 9500 1 Select Fonts Orientation Mode Number 10 Mode Name MODE10 4 Mode Configuration i Document Printer 12 MODE 10 Mode Name Ftswitch Pressed Undef Document Printer Status 3 Lvi Index Format Ftswitch Released Undef Fonts Orientation Supprs IA Display Form
146. r Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit English Ol Hardware Character Set erris Save Configuration to PC Load Configuration from PC Previous Menu Mode Configuration Unts End Session A 61097 May 1997 2 5 Programmable Function Keys P Keys 2 6 E Scanner 923 W Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 This option defines the functions performed by the programmable keys Refer to Appendix B Function Codes to determine which function codes and formats to use when programming the P Keys Select Programmable Function Keys Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session Mainframe Configuration m MACHINE STATE E Scanner 900 E Scanner 9500 p Key Definition P41 P2 P3 P4 P5 P6 P7 P8 P9 P10 Prev Previous Menu A 61097 May 1997 The defau
147. r every document until it is turned off Momentary Scanning Flag Allows you to set a flag which alerts the host system that the next document only is of special interest Footswitch Confirmation Tone Allows you to turn the footswitch confirmation tone on or off F66 Partial Bar Code Reading On Off f66 off disable Allows you to turn partial bar code reading on or off on enable t May be executed while transport is running Available when filming for use only with Microimager 70 with or without AFM and Scanner Microimager 990 Available when scanning for use only with the Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 Available when using advanced capabilities for use only with the Microimager 70 with AFM Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 A 61097 May 1997 B 5 P Key Definition Input Code Function Code Name Description Optional F76 OCR On Off off disable Allows you to turn OCR on or off on enable Document Sorter On Off Allows you to turn the document sorter on or off Sort Next Document to Specified Hopper Allows you to specify the hopper default upper or lower in which the next document only will be deposited F82t Sort All Documents to Specified Hopper Allows you to specify the hopper default upper or lower in which all documents will be deposited This 0 off disable 1 on enable definition will remain in effect for every d
148. r Customer Full IA is chosen the Check Digit options must be defined 3 94 A 61097 May 1997 If Message Number is selected the following window is displayed Current Print Sequence Display Values New Print Sequence Display Values I Message Number Message Number 1 Message Number 2 Message Number 3 Message Number 4 Message Number 5 Message Number 6 Message Number 7 Message Number 8 Message Number 9 Previous Menu ES 4 Select the desired message number If different information is to be printed on documents of different levels 5 Select Print Sequence Level for the desired level 6 Select the item s to be printed next to documents of the selected level in turn up to a maximum of thirty eight 38 characters including spaces NOTE If the definition exceeds the thirty eight 38 character limit the first thirty eight 38 characters will be printed on each document and the remainder of the information will be truncated A 61097 May 1997 3 95 Document Printer 12 NOTE The Document Printer 12 accessory must be installed W Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Doc Printer 12 E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 3 Lvl Supprs 4233 2112 None Auto Duplex Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode
149. r Secondary DP 1 O Off Skew Monitor Doc Printer 12 Ofi Xport Check Stacker Document Sorter Oi Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 5 Degrees 10 Degrees Previous Menu 2 Select the desired threshold 3 44 A 61097 May 1997 Skew Error Response This mode defines the action taken if the amount of document skew is greater than the threshold specified The default value is Display and Beep W Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Skew Err Response Mode Number 10 Mode Name MODE10 m Mode Configuration Skew Monitor MODE 10 Mode Name Ftswitch Pressed Undef Skew Peteri grais 3 Lvl Index Format Ftswitch Released Undef Skew E R Supprs IA Display Format Ftswitch Cnf Tone O OW EOR TOSPONSE 4233 IA Field Widths Patch Reader 1 Of Previous Menu 2112 Level Rules Patch Reader 2 O None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Of Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status O 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter O Off Endorser Mode Ove
150. ring machine configuration otherwise these definitions will be ignored LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Confirmation Tone E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 3 Lvl Supprs 4233 2112 None Auto Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Configuration MODE 10 Mode Name Mode Name MODE10 Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef lt TZOOQOQOQOUDNDOZOLOOO f S f f f f fe f f f 12 f NN ply Sav Confirmation Tone Patch Detected Tone Bar Detected Tone Bar Code Patch Tone Previous Menu Save amp End Session Previous Menu Don t Save amp End Session End Configuration 3 74 A 61097 May 1997 Patch Detected Tone NOTE Patch reading must be enabled In addition the confirmation tones must have been enabled during machine definitions otherwise this definition will be ignored This mode enables or dis
151. rmed follow these steps to log on to the Mode Setup Software 1 Access DOS 2 Change the directory to correspond to the directory designated during the installation procedure 3 Type setup and press Return Enter EASTMAN KODAK COMPANY Model 30 Model 70 AFM Model 70 s Model 900 Model 923 j Model DS990 Model DS9500 4 t OF This software is the property of Eastman Kodak Company It is not to be sold or leased in any form Use by any other individual is illegal and subject to penalties under the copyright laws of the United States Version Connect via RS 232 3 30 Connect via Modem i Release Date Copyright Exit Eastman Kodak Company MM DD YY 1989 1997 4 Select Connect via RS 232 and press Return Enter KODAK IMAGELINK tm DIGITAL SCIENCE tm Microimager Models 30 amp 70 Microimager Model 70 AFM Scanner 900 amp 923 Microimager Scanner DS990 Scanner DS9500 1 Attach RS 232 Cable 2 Turn Operator Power Switch ON 3 Press ENTER RETURN Key Continue Exit 1 6 A 61097 May 1997 5 Select Continue Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock
152. roimager 990 the Image Address Field widths for all modes may be defined NOTE A field width definition for all fields Field A Level 1 Field B Level 2 Field C Level 3 and Fixed Field must be specified 3 8 A 61097 May 1997 A 61097 May 1997 1 Select IA Field Widths Mode Number 10 MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used mA Mode Configuration t Mode Name MODE10 i Field Num Ftswitch Pressed Undef Se jeld Ftswitch Released Undef Field B Ftswitch Cnf Tone Off Fial de Patch Reader 1 Off Patch Reader 2 Off Previous Menu Patch Definition Lvl 2 Bar Code Off Confirmation Tone NNN OCR Status Off COIN User Channel On Printer Control Disply Primary DP 1 Off Secondary DP 1 Off Doc Printer 12 Off Document Sorter Off Mode Overrides No Sav Film Definition F Save amp End Session Previous Menu Don t Save amp End Session End Configuration 2 Select the field to be defined Mode Number 10 MODE 10 Mode Name 3 Lvl ndex Format Supprs A Display Format 4233 A Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 2222
153. rr Response Previous Menu Length Check Off or Disabled On or Enabled Previous Menu 2 Select the desired status NOTE If Off or Disabled is selected definitions for the remaining options will be ignored A 61097 May 1997 3 39 Maximum Document Length This mode defines the maximum document length accepted The default value is 13 000 inches 325 mm E Scanner 900 E Scanner 9500 WE Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Max Document Length Mode Number 10 Mode Name MODE10 mA Mode Configuration l Length Monitor Status MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef eee Supprs IA Display Format Ftswitch Cnf Tone Off ie hen Be eng 4233 IA Field Widths Patch Reader 1 O AEA DOP a 2112 Level Rules Patch Reader 2 O Previous Menu None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code O Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Enter Max Doc Length Not Used Film Definition F Range 2 50 75 000 g 0013 00 inches Save amp End Session Don t S
154. rrides No Sav he Not Used Film Definition F Skewed Eror Hesponee Display Display and Beep Save amp End Session Don t Save amp End Session Stop and Display Previous Menu End Configuration Previous Menu 2 Select the desired error response action A 61097 May 1997 3 45 Check Stacker NOTE The Check Stacker must be installed This mode defines when the check stacker is activated Continuous will activate the check stacker whenever the side panel switch is on Documents in Transport will activate the check stacker only when there are documents exiting the transport The default value is Documents in Transport W Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Check Stacker E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 3 Lvl Supprs 4233 2112 None Auto Duplex Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Configuration MODE 10 Mode Name Mode Name MODE10 Check Stacker Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film
155. ry DP 1 Oi Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 Ofi Xport Check Stacker Document Sorter O Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration 3 38 A 61097 May 1997 Status This mode enables or disables length monitoring The default value is Off or Disabled W Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select Status E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 3 Lvl Supprs 4233 2112 None Auto m Mode Configuration MODE 10 Mode Name Index Format IA Display Format IA Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer Image Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch Reader 1 Oi Patch Reader 2 O Patch Definition Lvl 2 Bar Code Oi Confirmation Tone NNN OCR Status Of COIN User Channel On Printer Control Di Primary DP 1 Oi Secondary DP 1 O Doc Printer 12 O Document Sorter O Mode Overrides No Sav Film Definition E Save amp End Session Previous Menu Don t Save amp End Session End Configuration qo Length Monitor Status Max Document Length Min Document Length Length E
156. s Current Day New Print Sequence Display Values Current Date Current Time Document Counter Roll Number Message 1 9 Check Digit Nothing Printed Previous Menu When using a Microimager 70 without the Advanced Function Module installed a limited number of items may be selected The available items are e Full IA w All Delimiter e Indexed Fields Only e Nothing Printed When using a Microimager 70 with the Advanced Function Module installed all of the items are available for selection with a maximum of 38 characters including spaces NOTE If the definition exceeds the 38 character limit the first 38 characters will be printed on each document and the remainder of the information will be truncated 2 Select the item s to be printed A 61097 May 1997 3 87 If Spaces between items is selected you must select the desired number of spaces If Check Digit is selected the following window is displayed H Check Digit H Mod 7A IA Only Mod 11A IA Only Mod 7B IA Only Mod 7B Full lA Mod 10 IA Only Mod 10 Full IA Mod 11B IA Only Mod 11B Full lA Custom IA Only Custom Full IA Previous Menu Current Print Sequence Display Values New Print Sequence Display Values 2 Select the desired check digit calculation If an option which indicates A Only is chosen the level fields of the Image
157. s None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session Previous Menu Don t Save amp End Session End Configuration A Printer Control E IA Print Format Print Position Special Character Set Previous Menu This mode defines the format used by the document printer s when printing the Image Address The default value is Display LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 Select A Print Format E Scanner Microimager 990 E Scanner 900 E Scanner 9500 Mode Number 10 mA Mode Configuration MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Printer Control Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Off Patch Reader 1 Off Patch Reader 2 Off Patch Definition Lvi 2 Bar Code Off Confirmation Tone NNN OCR Status Off COIN User Channel On Printer Control Disply Primary DP 1 Off Secondary DP 1 Off Doc Printer 12 Off Document Sorter Off Mode Overrides No Sav Film Defi
158. s not selectable It is for future use only 3 50 A 61097 May 1997 Footswitch Pressed NOTE The Footswitch accessory must be installed This mode defines the action which results when the footswitch is pressed The default is Undefined E Scanner 900 E Scanner 9500 W Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 When using a Microimager 70 without the Advanced Function Module installed a limited number of actions are available The available actions are e Undefined e Level 0 e Level 1 e Level 2 e Level 3 e Increment When using a Microimager 70 with the Advanced Function Module installed Scanner 900 Scanner 923 Scanner 9500 or Scanner Microimager 990 all of the actions listed are available 1 Select Ftswitch Pressed Mode Number 10 Mode Name MODE10 Mode Configuration Footswitch Pressed MODE 10 Mode Name Ftswitch Pressed Undef felon 3 Lvl Index Format Ftswitch Released Undef Level 4 Supprs IA Display Format Ftswitch Cnf Tone O Love 2 4233 IA Field Widths Patch Reader 1 O Level 3 2112 Level Rules Patch Reader 2 Of None Batching Patch Definition Lvl 2 Increment Auto AEC Mode Bar Code Of Sustained Level 0 F Sustained Level 1 Duplex Film Mode Confirmation Tone NNN Sustained Level 2 22222 Reduction Ratio OCR Status O Sustained Level 3 1 Roll of Cassettes COIN User Channel On Function Ke Comic Film Writer Printer
159. sed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch Reader 1 Of Patch Reader 2 Off Patch Definition Lvl 2 Bar Code Of Confirmation Tone NNN OCR Status Oi COIN User Channel On Printer Control Disply Primary DP 1 Of Secondary DP 1 Off Doc Printer 12 O Document Sorter O Mode Overrides No Sav Film Definition F IA Print Format Print Position Special Character Set Previous Menu f Character Set Save amp End Session Previous Menu Don t Save amp End Session End Configuration Use Smaller Font Use Larger Font Previous Menu 2 Select the desired font size A 61097 May 1997 Primary Document Printer 1 Document Printer Status NOTE A Document Printer 1 accessory must be installed E Microimager 70 W Microimager 70 AFM E Scanner 923 E Scanner Microimager 990 1 Select Primary DP 1 E Scanner 900 E Scanner 9500 Primary Document Printer Document Printer Status Fonts Orientation Same Format per Level Print Sequence Level 0 Print Sequence Level 1 Print Sequence Level 2 Print Sequence Level 3 Previous Menu Mode Number 10 Mode Name MODE10 Mode Configuration MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef Supprs IA Display Format Ftswitch Cnf Tone Off 4233 IA Field Widths Patch Reader 1 Off 2112 Level Rules Patch Reader 2 Off None Batc
160. t Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session Previous Menu Don t Save amp End Session End Configuration Enables or disables skew detection The default value is Off or Disabled WE Microimager 70 W Microimager 70 AFM E Scanner 923 1 E Scanner Microimager 990 Select Skew Detect Status E Scanner 900 E Scanner 9500 Mode Number 10 m Mode Configuration Mode Name MODE10 Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch Reader 1 Off Patch Reader 2 Oi Patch Definition Lvl 2 Bar Code Off Confirmation Tone NNN OCR Status O COIN User Channel On Printer Control Disply Primary DP 1 Off Secondary DP 1 O Doc Printer 12 O Document Sorter Of Mode Overrides No Sav Film Definition F A Skew Monitor Skew Detect Status Skew Threshold Skew Error Response Previous Menu Skew Status MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Save amp End Session Previous Menu Don t Save amp End Session End Configuration Off or Disabled On or Enabled Previous Me
161. t Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Save amp End Session Don t Save amp End Session Previous Menu End Configuration Status IMT Search Prg Number Magnification Splice Definition Image Mark Sizes Image Polarity Duplex Front Location Film Image Orientation Image Offset Previous Menu Enter Image Offset 000 Range 0 127 2 Enter a number within the range 0 127 3 37 Length Monitor NOTE The Advanced Document Controller must be installed W Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select Length Monitor Mode Number 10 Mode Name MODE10 Mode Configuration Length Monitor MODE 10 Mode Name Ftswitch Pressed Undef Nee Dorine Length 3 Lvi Index Format Ftswitch Released Undef Min D t Length Supprs IA Display Format Ftswitch Cnf Tone O Ue Renae eng 4233 IA Field Widths Patch Reader 1 Ol ength Err Response 2112 Level Rules Patch Reader 2 O Previous Menu None Batching Patch Definition Lvi 2 Auto AEC Mode Bar Code Oi Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Prima
162. tatus COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef 8 SSeS N Zz RARAARRG Ss lt TZO0Q9 9QOD09Z0FO99 n o lt Patch 2 Status Save amp End Session Previous Menu Don t Save amp End Session End Configuration Off or Disabled On or Enabled Previous Menu 2 Select the desired status NOTE IF Off or Disabled is selected the definitions for the remaining patch options will be ignored If you have a DSA this option is not available A 61097 May 1997 3 55 Patch Definition 3 56 E Scanner 923 Array must be installed Select Patch Definition E Microimager 70 W Microimager 70 AFM E Scanner Microimager 990 NOTE At least one Patch Reader accessory or Document Scanning E Scanner 900 E Scanner 9500 Mode Number 10 mA Mode Configuration MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Name MODE10 Patch Definition Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone Of Patch Reader 1 Of Patch Reader 2 Of Pat
163. te Print Template Print Template ITEM LINE PRINT ITEM ITEM LINE PRINT ITEM ITEM LINE PRINT ITEM 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 12 12 12 Print Template Print Template Print Template ITEM LINE PRINT ITEM ITEM LINE PRINT ITEM ITEM LINE PRINT ITEM 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 E 7 8 8 8 9 9 9 10 10 10 11 11 11 12 12 12 Print Template ITEM LINE PRINT ITEM 1 2 3 4 5 6 r 8 9 10 11 12 A 61097 May 1997 Mode Definitions Q Original Setup Filename May be linked with Mode s 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 Q Update enter date cfg Mode Name Index Format Image Address Display Format Image Address Field Widths Fixed Field Field C Level 3 Field B Level 2 Field A Level 1 Level Rules Level 0 followed by Level 1 followed by Level 2 followed by Level 3 followed by Batching 24 1 Batch Level 24 2 Batch Value 24 3 Start of Batch 24 4 End of Batch AEC Mode Film Mode Reduction Ratio Minimum Number of Cassettes Film Writer 29 1 Char Orientation 29 2 IA Print Format 29 3 Write Definitions Level 0 Level 1 Level 2 Level 3 Image Management Code 30 1 Status 30 2 Search Prog 30 3 Magnification 30 4 Splice Definition 30 5 Image Mark Sizes 30 6 Image Polarity 30 7 Dup Front Loc 30 8 Film Image Orien 30 9 Image Offset 3
164. ted Tone may be enabled A 61097 May 1997 3 75 Bar Detected Tone 3 76 NOTE Bar Code reading must be enabled In addition during machine definitions the confirmation tones must have been enabled otherwise this definition will be ignored Enables or disables a confirmation tone issued when a bar code document is detected The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 MH Scanner 9500 1 Select Bar Detected Tone Mode Number 10 Mode Name MODE10 mA Mode Configuration A Confirmation Tone MODE 10 Mode Name Ftswitch Pressed Undef Patch Detected Tone 3 Lvi Index Format Ftswitch Released Undef Bar Detected Tone Supprs IA Display Format Ftswitch Cnf Tone Off Bar Code Patch Tone 4233 IA Field Widths Patch Reader 1 Off Previous Menu 2112 Level Rules Patch Reader 2 Off None Batching Patch Definition Lvl 2 Auto AEC Mode Bar Code Off Duplex Film Mode Confirmation Tone NNN 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 Off Off Length Monitor Secondary DP 1 Off Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F BarC deTone Off or Disabled Save amp End Session Don t Save amp End Session On or Enabled
165. tion to determine the reduction allowed based upon the Film Mode selected If the film mode is Simplex you may select 50X 40X or 24X If the film mode is Duplex you may select 50X or 40X If the film mode is Duo you may select 50X or 40X NOTE This selection is not available on the scanners A 61097 May 1997 3 21 Number of Cassettes This mode defines the minimum number of cassettes that must be installed during filming If Two Cassettes is chosen you must always use two cassettes If One Cassette is chosen you may use one or two cassettes The default value is One Cassette WE Microimager 70 W Microimager 70 AFM L Scanner 923 1 Select of Cassettes E Scanner Microimager 990 LJ Scanner 900 LJ Scanner 9500 3 Lvl Supprs 4233 2112 None Auto Duplex Mode Number 10 mA Mode Configuration MODE 10 Mode Name ndex Format A Display Format A Field Widths Level Rules Batching AEC Mode Film Mode Reduction Ratio of Cassettes Film Writer mage Mgmt Code Length Monitor Skew Monitor Check Stacker Endorser Not Used Mode Name MODE10 Ftswitch Pressed Ftswitch Released Ftswitch Cnf Tone Patch Reader 1 Patch Reader 2 Patch Definition Bar Code Confirmation Tone OCR Status COIN User Channel Printer Control Primary DP 1 Secondary DP 1 Doc Printer 12 Document Sorter Mode Overrides Film Definition Undef Undef Of Of Of Lvl 2 Of NNN Of On Disply Of
166. tions will be ignored NOTE If the status is defined as Off or Disabled definitions for the 3 29 IMT Search Program Number This mode defines the IMT search program number The default value is 00 1 Scanner 900 LJ Scanner 9500 E Microimager 70 W Microimager 70 AFM LJ Scanner 923 E Scanner Microimager 990 1 Select IMT Search Prg Number Mode Number 10 Mode Name MODE10 mA Mode Configuration H Image Management Codey Status MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl ndex Format Ftswitch Released Undef vi tat Prg Number Supprs IA Display Format Ftswitch Cnf Tone O agniiicauon Splice Definition 4233 A Field Widths Patch Reader 1 O Image Mark Sizes 2112 Level Rules Patch Reader 2 Ofi Image Polarit None Batching Patch Definition Lvl 2 ag Yooh Duplex Front Location Auto AEC Mode Bar Code O i F Film Image Orientation Duplex Film Mode Confirmation Tone NNN Image Offset 22222 Reduction Ratio OCR Status Off 1 Roll of Cassettes COIN User Channel On Previous Menu Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 Of Off Skew Monitor Doc Printer 12 Off Xport Check Stacker Document Sorter Oi Off Endorser Mode Overrides No Sav Not Used Film Definition F Enter Program Number z 00 Save amp End Session Don t Save amp End Session Previous Menu End Configuration Range O 70
167. u Splice Ignore Level 1 Level 2 Level 3 Previous Menu 2 Select the desired action 3 32 A 61097 May 1997 Image Mark Sizes This mode defines the image mark sizes used small medium and large The default value is Kodak Standard W Microimager 70 W Microimager 70 AFM LI Scanner 900 LJ Scanner 923 E Scanner Microimager 990 J Scanner 9500 1 Select Image Mark Sizes Mode Number 10 Mode Name MODE10 mA Mode Configuration H Image Management Code H Status MODE 10 Mode Name Ftswitch Pressed Undef 3 Lvl Index Format Ftswitch Released Undef ie be Prg Number Supprs IA Display Format Ftswitch Cnf Tone Off S Ibe Definition 4233 IA Field Widths Patch Reader 1 O R Image Mark Sizes 2112 Level Rules Patch Reader 2 O Im Polarit None Batching Patch Definition Lvl 2 AJET DAYS os Duplex Front Location Auto AEC Mode Bar Code A i 5 x A Film Image Orientation Duplex Film Mode Confirmation Tone NNN Image Offset 22222 Reduction Ratio OCR Status Of 1 Roll of Cassettes COIN User Channel On Previous Menu Comic Film Writer Printer Control Disply Off Image Mgmt Code Primary DP 1 O Off Length Monitor Secondary DP 1 O Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter Off Off Endorser Mode Overrides No Sav Not Used Film Definition F Image Mark Size Custom Setup Save amp End
168. ue is Disabled WE Microimager 70 W Microimager 70 AFM E Scanner 900 E Scanner 923 E Scanner Microimager 990 W Scanner 9500 1 Select User COIN Port Protocol 2 Select the desired User COIN Port protocol Mainframe Configuration Display Machine Accessories MACHINE STATE Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers F User COIN Port Protocol User COIN Port Protocol Disabled Custom Check Digit Bar Code KDIS Protocol Ql Fardware Character Set User Defined KDIS Format Save Configuration to PC Load Configuration from PC OCR Data Protocol Mode Configuration User Defined Protocol End Session Previous Menu Bar Code KDIS Protocol should be selected when using the Bar Code Accessory This communications protocol does not call for handshaking between the Microimager 70 Scanner 900 Scanner 923 Scanner 9500 or Scanner Microimager 990 and the host system OCR Data Protocol should be selected when using the OCR accessory This communications protocol calls for handshaking between the Microimager 70 Scanner 900 Scanner 923 or Scanner Microimager 990 and the host system A 61097 May 1997 2 25 2 26 If User Defined Protocol is selected the following window
169. urge Frequency Allows you to specify how often in terms of the number of documents fed into the transport a 0 off disable on enable 0 off disable 1 on enable priming ink spurt is initiated Patch Reader 1 On Off Allows you to turn the primary patch reader on or off F51 Patch Reader 2 On Off t Allows you to turn the secondary patch reader on or off 5 F52 End Fed Patch Reading On Off f52 0 off disable Allows you to turn end fed patch reading on or off 1_ on enable F53 Patch Reading Confirmation Tone off disable Allows you to turn the patch reading confirmation on enable 143 144 145 46 49 50 51 tone on or off F54t Omit Patch Reading on Next Document Only 54 Allows you to omit patch reading on the next document only Printer Open Jet Test f56 Allows you to determine whether or not there are non functional ink jets in the Document Printer 12 ink cartridge 57 Endorser On Off f57 0 Off disable Allows you to turn the endorser on or off 1 on enable Endorser Mode f58 Allows you to display the current endorser mode and or change the endorser mode t May be executed while transport is running Available when filming for use only with Microimager 70 with or without AFM and Scanner Microimager 990 Available when scanning for use only with the Scanner 900 Scanner 923 Scanner 9500 and Scanner Microimager 990 Available when using advanced capabilities for use only with
170. us Off Length Monitor Secondary DP 1 O Level Change via Bar Code Off Skew Monitor Doc Printer 12 O Xport Check Stacker Document Sorter O Previous Menu Off Endorser Mode Overrides No Sav Not Used Film Definition F lt 1 Scan Direction i 7 A Uni directional Save amp End Session Don t Save amp End Session Bi directional Previous Menu End Configuration Previous Menu 2 Select the desired scan direction A 61097 May 1997 Image Processing A 61097 May 1997 Enables or disables image processing indicates whether or not image processing is required to enhance the overall quality of the bar codes used The default value is Off or Disabled LJ Microimager 70 W Microimager 70 AFM E Scanner 923 1 E Scanner Microimager 990 Select mage Processing E Scanner 900 E Scanner 9500 Mode Number 10 MODE 10 Mode Name 3 Lvl Index Format Supprs IA Display Format 4233 IA Field Widths 2112 Level Rules None Batching Auto AEC Mode Duplex Film Mode 22222 Reduction Ratio 1 Roll of Cassettes Comic Film Writer Off Image Mgmt Code Off Length Monitor Off Skew Monitor Xport Check Stacker Off Endorser Not Used Mode Configuration Mode Name MODE10 Bar Code Reader E Ftswitch Pressed Undef Ftswitch Released Undef Ftswitch Cnf Tone O Patch Reader 1 O Patch Reader 2 O Patch Definition Lvl 2 Bar Code O Confirmation Tone NNN OCR Status Off COIN User Channel
171. will be displayed Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from PC Mode Configuration End Session m MACHINE STATE c User COIN Port Config Baud Rate 9600 Parity Bit None Char Length 8 Bits Handshaking None Update FF Update Previous Menu m User COIN Port Protocol Disabled Bar Code KDIS Protocol User Defined KDIS Format OCR Data Protocol User Defined Protocol Previous Menu Enter the required configuration information by selecting each of the configuration options in turn and entering the appropriate values 3 Select Baud Rate 4 Select the desired baud rate Mainframe Configuration Display Machine Accessories Machine ID Number Display Language Measurement System Programmable Function Keys Date Format Time Format Alarm Tone Doc Printer Film Writer Msg DP 12 Print Template Fixed Field Delimiter Set System Clock Version Numbers User COIN Port Protocol Custom Check Digit Ol Hardware Character Set Save Configuration to PC Load Configuration from P
172. y Values Message 1 Message 2 Message 3 Message 4 Message 5 Message 6 Message 7 Message 8 Message 9 Nothing Printed Previous Menu lt Full IA gt lt 2 Sp gt lt Date gt lt 2Sp gt lt Time gt Default is lt FF IA All Del gt 2 Select the item s to be printed NOTE If the definition exceeds the thirty eight 38 character limit the first thirty eight 38 characters will be printed on film next to each document and the remainder of the information will be truncated New information will appear in the New Print Sequence Display Values box When you press Enter the print sequence will appear in the upper box 3 26 A 61097 May 1997 A 61097 May 1997 If different information is to be printed next to documents of different levels 1 Select Print Sequence Level for the desired level Current Print Sequence Display Values lt Full IA gt lt 2 Sp gt lt Date gt lt 2Sp gt lt Time gt Default is lt FF IA All Del gt New Print Sequence Display Values f4 FAN Write Sequence Full Image Address Indexed Fields Only Current Field Level Spaces between Items Current Day Current Date Current Time Document Counter Message 1 Message 2 Message 3 Message 4 Message 5 Message 6 Message 7 Message 8 Message 9 Nothing Printed Previous Menu 2 Select the item s to be printed NOTE

Download Pdf Manuals

image

Related Search

Related Contents

LG LW1512ER Energy Guide  Chave de Impacto 1” Manual de Operações  HP Color LaserJet CP1210 Series Printer User Guide  Method for managing the assignment of device drivers in a computer  Cormidi KB Series Crane - Operation Manual  Kenwood KTC-HR100 Radio User Manual    Dicota 2 Network Card User Manual  user manual Safety precautions  Guía de instalación rápida  

Copyright © All rights reserved.
Failed to retrieve file