Home

Kobe Range Hoods CH-100 CH0030SQB User's Manual

image

Contents

1. Purchased Date Purchased From IMPORTANT PLEASE KEEP A COPY OF YOUR SALE RECEIPT OR INVOICE HANDY WHEN REQUESTING FOR SERVICE 26
2. CHO0048DC 12 B102 6012 048 Screw 3 16 x 3 8 C1 0707 0001 RECIRCULATING KIT NO DESCRIPTION MODEL SIZE PART NO 01 Hood Mounting Bracket C1 0221 0330 Screw 3 16 3 8 1 0707 0001 03 T Head Box A Box C1 0241 2130 FA 6 12 C1 0241 2136 FA CH0042RD 12 C1 0241 2142 FA CH0048RD 12 C1 0241 2148 FA B Box Bracket 12 1 0241 2130 6 12 1 0241 2136 CH0042RD 12 C1 0241 2142 FB CH0042RD 12 C1 0241 2148 FB Box Panel Let 1 02092130 Right C1 0209 2130 FB 04 Screw 3 16 x 3 8 C1 0707 0001 05 Pipe 1 0601 0004 06 6 Round Plastic Exhaust O 1 0505 0001 07 Recirculating Duct Cover B102 6012 030 F B102 6012 036 F B102 6012 042 F B102 6012 048 F 08 Screw 3 16 x 3 8 C1 0707 0001 09 Screw 3 16 x 3 8 1 0707 0001 10 jCharoalFiter Cf 0603 0302 MODEL NO CH0030SQB CH0036SQB DUCT COVER ee 00305 a MODEL NO CH0042SQB DUCT COVER CH0042SQB SS 186 e CH0048SQB MODEL NO DUCT COVER O lt lt O x O LLI x CH0048SQB 20 CIRCUIT DIAGRAM CH0030SQB CH0036SQB MODEL NO 20 YELLOW BROWN 3 HALOGEN LIGHTS BLUE NEED c 2 9 P
3. x 24 x 18 1 Original Kit Duct Cover Model No CH0030DC 12 30 x 12 x 12 Model No CH0036DC 12 36 x 12 x 12 Model No CH0042DC 12 42 x 12 x 12 Model No 0480 12 48 x 12 x 12 2 Recirculating Kit Recirculating Duct Cover Model No CH0030RD 12 30 x 12 x 12 Model No CH0036RD 12 36 x 12 x 12 Model No CH0042RD 12 42 x 12 x 12 Model No 048 12 48 x 12 x 12 3 Model No SSP30 30 Stainless Steel Back Panel 30 x 1 10 x 32 4 Model No SSP36 36 Stainless Steel Back Panel 36 x 1 10 x 32 Net Gross CH0030SQB 61 0 74 0 CH0036SQB 70 0 86 0 CH0042SQB 82 0 100 0 CH0048SQB 88 0 114 0 QuietMode Low Medium High 280 400 420 600 580 800 760 1000 1 2 2 8 2 0 4 0 2 8 5 6 4 5 8 0 House Test Static Pressure 0 One sone is equivalent to the sound of a refrigerator at 40 decibels Specifications subject to change without notice 13 MEASUREMENTS 8 DIAGRAMS Allmeasurements are millimeters Allinch measurements are converted from millimeters Inch measurements are estimated FOR UNDER THE CABINET MODEL NO CH0030SQB MODEL NO CH0048SQB CH0036SQB CH0042SQB FOR STAND ALONE WITH OPTIONAL DUCT COVER MODEL NO CH0030SQB MODEL NO CH0048SQB CH0036SQB CH0042SQB 08 8 L 30 762 MAX Rear Knockout Holes BAFFLE FILTERS amp BOTTOM CASINGS 30 HOOD 15 Hood
4. 2 9 O OE ES s VHINSIOJSNVLLE L Mu C lt hi da 14405 GROUND E poe 120V AOV Td WHITE NITAD AO TIHA day MOV Ta 21 CH0042SQB CH0048SQB MODEL NO NMO 18 ang ALHA l c gt 2 Q O amp gt 15 qna 5 908 F BS 2 Zs d J a ez B 5 3 E mis TVULNAN ALIHAMA 144118 2 i m 120V AC gt Q lt ea GROUND 120 250W WHITE TIHA MOV Ta 22 DISCLAIMER 1 CAREFULLY INSPECT ALL ITEMS FOR DAMAGES DELIVERY NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT REQUEST NAME AND SIGNATURE OF THE CARRIER S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM Upon acceptance of items owner assumes responsibility for its safe arrival Damages should be reported to carrier and a claim filed Failure to do this could result in the carrier refusing to honor your claim The carrier will furnish you with necessary forms for filing a claim DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR WARRANTY PLEASE INSPECT CONTENTS OF PACKAGE S CAREFULLY UPON RECEIVING We m
5. unit only in the manner intended by the manufacturer Before servicing switch power off at service panel and lock service panel if possible to prevent power from switching on accidentally 8 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan and baffles What to Do In The Event Of a Range Top Grease Fire SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray and then turn off the burner KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES If the flames do not go out immediately EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911 NEVER PICK UP A BURNING PAN You May Get Burned DO NOT USE WATER including wet dishcloths or towels a violent steam blast will result Use an extinguisher ONLY if a You have a Class A B C extinguisher and know how to operate it b The fire is small and contained in the area where it started C The fire department has been called d You can fight the fire with your back to an exit What to Do If You Smell Gas Extinguish any open flame Do not try to turn on the lights or any type of appliance Open all doors and windows to disperse the gas you still smell gas call the Gas Company and Fire Department right away 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork 3 Follow the heating equipment ma
6. E GAS BEFORE MOVING A GAS RANGE Figure 11 1 Using references on Table 2 and measurements on page 14 15 mark the leveling point of the hood Position two mounting screws not provided on the wall leaving 1 8 away from the wall as shown in Figure 11 2 Align hood mounting bracket to the two Figure 12 screws on the wall and hook hood into place Tighten screws to secure hood to the wall 3 For safety purposes extra knockout holes on the back of the hood are provided Knockout the holes Remove the baffle filters and attach screws to the wall by accessing underneath the hood CAUTION MAKE SURE HOOD 15 SUCURE BEFORE RELEASING Wiring to Power Supply Wire Connector 4 Figure 13 SAFETY WARNING RISK OF ELECTRICAL 5 THIS wawanman RANGE HOOD MUST BE PROPERLY Steel Pipe GROUNDED MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN Duct Tape ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL Mouse CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY 4 Connect the electrical wires Connect three wires black white and Figure 14 green to house wires and cap with wire connectors Connect according to color black to black white to white and green to green as shown on Figure 12 If necessary to hide the electrical wire connections push wires back into the wiring box Access the wire con
7. IRCULATING KIT ALSO AVAILABLE 9 FOR MORE INFORMATION PLEASE CONTACT KOBE RANGE HOODS 626 309 1356 3 INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation Calculate the length of the installation before installing the hood All calculation is measure in inches FOR UNDER THE CABINET TABLE 1 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Recommended 27 to 30 D Height of Hood E Height of the Cabinet TABLE 2 Duct Cover A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Recommended 27 to 30 B D D Height of Hood E Height of Duct Cover sarety WARNING HOOD MAY HAVE VERY SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Contents Under the Cabinet Stand Alone UNDER THE CABINET INSTALLATION Preparation before Installation Figure 1 NOTE TO AVOID DAMAGE TO YOUR HOOD PREVENT DEBRIS FROM ROOF CAP ENTERING THE VENT OPENING e Decide the location of the venting pipe from the hood to the outside Refer to Figure 1 CABINET e A straight short venting run will allow the hood to perfor
8. KORBE KOBE Brand Range Hood Model No CH0030SQB CH0036SQB CH0042SQB CH0048SQB CH 100 SERIES 18 HEIGHT INSTALLATION INSTRUCTIONS AND OPERATION MANUAL READ AND SAVE THESE INSTRUCTIONS CONTENTS important Safety IIISITOGUOnSu 2 u ox te u qosaq 1 Colripohients OT Packade iade E 3 SO 4 11 112 12 Secllecalons 13 Measurements amp 14 C 16 CW CII MON AG AUN aaa 21 GUAM lita ds oe ER 23 md 24 e ONS RAMON 26 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES 221547 IMPORTANT SAFETY INSTRUCTIONS PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY OBSERVE THE FOLLOWING 1 Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards including fire rated construction 2 When cutting or drilling into wall or ceiling be careful
9. LIGHT UNIT MAY BE HOT WAIT UNTIL UNIT IS COOL HALOGEN LIGHT BULB 12V 20W y Make sure all controls are off and range hood is unplugged Place the flat headed screwdriver into the groove of the halogen light glass covering and the housing Pop out the halogen light glass covering Gently pull out the defective light bulb and discard Light bulbs should be 12V 20W maximum Using a cloth hold the new light bulb and push securely into light socket Return halogen light glass cover to the housing Turn range hood ON to test for operation 12 SPECIFICATIONS MODEL SIZE COLOR VOLTAGE NUMBER OF MOTORS DESIGN FAN TYPE CENTRIFUGAL EXHAUST CONTROLS HALOGEN LIGHTS HOOD DIMENSION W x D x H OPTIONAL ACCESSORIES W x D x H HOOD WEIGHT Ibs SPEED Air Capacity cfm 1 Motor 2 Motors Sone 1 Motor 2 Motors 00305 30 00365 36 CH0042SQB 42 00485 48 304 Commercial Grade Stainless Steel 120V 60Hz 1 30 36 42 2 48 18 Gauge Seamless Satin Finish Squirrel Cage Top 6 Round x 1 30 36 42 Top 6 Round x 2 48 7 Round Adapter Electronic Control 4 Buttons 10 Second Standby Startup 30 Second Delay Shutoff 12V 20W x 2 30 36 12V 20W x 3 42 48 00305 29 3 4 x 24 x 18 00365 35 3 4 x 24 x 18 00425 41 3 4 x 24 18 00485 47 3 4
10. Mounting Bracket 3 4 20 1 3 8 35 v6 9L LL 3 16 5 E k 4 1 16 104 4 1 16 104 9 3 8 238 7 S 08 8 L PARTS LIST MODEL NO CH0030SQB CH0036SQB CH0042SQB CH0048SQB DESCRIPTION MODEL SIZE PART NO 1 7 Round Adapter Fo 1 0505 0004 2 6 Round Plastic Exhaust Hood Casing CH0048SQB 10 2148 4 ConroUnt 72 O1 050101001 5 ConroBoad OC1 04040401 A 6 Halogen Light Unit 12V 20W Max 1 0403 0101 7 77 1 30202001 8 LampSocketCover 7 15 020440 9 OC1 04140120 10 SafetyScreen 2 1 0602 0103 11 Capacitor Panel 00305 1 0201 2130 CH0036SQB C1 0201 2136 CH0042SQB C1 0201 2142 CH0048SQB C1 0201 2148 Transformer Light CH0030SQB C1 0402 0120 40 CH0042SQB C1 0402 0120 60 C1 0401 0120 03 Capacitor Transformer Motor C1 0402 A 120 01 Processor Board Box r C1 0501 0102 Board 7 1 0404 04018 11 13 14 17 18 Bottom Casing E C 5 1 4 Wide 19 Baffle Fitter 1045 O Screw 1 8 x 3 8 C1 0708 0003 16 Optional Duct Cover ORIGINAL KIT NO DESCRIPTION MODEL SIZE PART NO Hood Mounting Bracket P 1 0221 0330 Screw 3 16 x 3 8 1 0707 0001 03 Duct Cover CH0030DC 12 B102 6012 030 CH0036DC 12 B102 6012 036 CH0042DC 12 B102 6012 042
11. ON Figure 6 Figure Final Assembly 12 Turn power ON in control panel Check all lights and fan operation STAND ALONE INSTALLATION This installation only applied with the Figure 8 purchase of an optional duct cover ROOF CAP Preparation before Installation NOTE TO AVOID DAMAGE TO YOUR HOOD PREVENT DEBRIS FROM ENTERING THE VENT OPENING e Decide the location of the venting pipe from the hood to the outside Refer to Figure 8 A straight short venting run will allow the hood to perform more efficiently e Try to avoid as many transitions Figure 9 elbows and long run as possible This may reduce the performance of the hood WALL STUDS Use duct tape to seal the joints between pipe sections If necessary prepare back wall frame with cross framing lumber for secure installation Using references on Table 2 and measurements on page 14 15 decide the level of the lumber Refer to Figure 9 Hood Preparation before Installation e Temporarily wire the hood to test for proper operation before installing e Important Peel protective film off the hood and the duct cover if any e Attach the hood mounting brackets to the back of the hood with 3 16 x 3 8 screws provided as shown In Figure 10 Hood Installation CAUTION If required to move the cooking range to install the hood turn off the power on an electric range at the main electrical box SHUT OFF TH
12. THS Regular care will help preserve its fine appearance 1 2 Use only mild soap or detergent solutions Dry surfaces using soft cloth If hood looks splotchy stainless steel hood use an orange base cleaner to clean the surface of the hood Avoid cleaner to get on the control switches Only spread a light coating over the surface of the hood and leave on for a few minutes do not leave on too long or this may cause damage to hood finish Use soft towel to wipe off the cleaning solution gently rubs any stubborn spots Use a slightly damp towel to get rid of any cleaning solution Use dry soft towel to dry the hood To bring the glow back into a stainless steel finish use a stainless steel cleaner DO NOT allow deposits to remain for long periods of time DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean cloth To Clean Baffle Filters CAUTION DRAIN BAFFLE FILTERS BEFORE OIL WILL OVERFLOW 1 2 Remove the baffle filters by sliding forward and pull downward Wash with warm soapy water Dry completely before returning into place Note Baffle Filters are top rack dishwasher safe CAUTION HALOGEN
13. ale by the laws of the state of sale are limited to two year from the date of original purchase Some states do not allow limitations on the duration of implied warranties This warranty gives you specific legal rights and may also have rights which vary from state to state SERVICE For service contact KOBE Range Hoods Inc 4934 Walnut Grove Avenue Suite 202 oan Gabriel CA 91776 U S A Tel 626 309 1356 Fax 626 309 1366 Email customerservice koberangehoods com www KobeRangeHoods com 25 PRODUCT REGISTRATION Register Your Product Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired or at our option the unit will be replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as applicable Keep proof of purchase original invoice handy for inspection If the range hood is sold by the original purchaser during the warranty period the new owner is protected until expiration of the original purchasers warranty See warranty section for complete warranty coverage information This appliance has been manufactured tested and inspected to the standards required by KOBE Range Hoods PLEASE MAIL IN YOUR WARRANTY REGISTRATION CARD AND PROOF OF PURCHASE TO KOBE Range Hoods Inc 4934 Walnut Grove Avenue Suite 202 San Gabriel CA 91776 RECORD THE FOLLOWING INFORMATION FOR YOUR RECORD Model No
14. ected to improper inadequate or faulty electricity service or exhaust ducts or flues or operated using incorrect or contaminated lubricants iii installed maintained or operated otherwise than in accordance with the instructions furnished by KOBE Range Hoods including the improper use of detergents bleaches or cleaners g for damage to range hood during transit delivery installation or removal h for damage by or resulting from attempted repairs conducted by anyone other than our Authorized Service Agent 3 The purchaser shall be responsible for any expenses involved in making the range hood readily accessible for servicing and where the range hood is installed outside the main sales territory of the retailer or service territory of the nearest approved KOBE Range Hoods Agent as applicable for any traveling expenses and any costs of transporting the range hood or parts thereof to and from the dealer or Service Agent 4 The purchaser must produce proof of purchase together with this warranty certificate when making the claim 5 Damages caused during shipment are not covered under our warranty 24 CONSEQUENTIAL DAMAGE The warrantor is not responsible for any consequential damage SOME STATES DO NOT ALLOW THE EXCLUSION OF CONSEQUENTIAL DAMAGE SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU IMPLIED WARRANTIES STATE LAW Any implied warranties including the implied warranty of merchantability and fitness for purpose imposed on the s
15. m more efficiently e to avoid as many transitions elbows and long run as possible This may reduce the performance of the hood Figure 2 e Temporarily wire the hood to test for proper operation before installing e Important Peel protective film off the hood if any e For installing under the cabinet with recessed bottom attach 4 inch wide wood filler strips not included on each side Refer to Figure 2 Measure and create access opening for electrical wires and plastic exhaust under the cabinet Hood Installation CAUTION If required to move the cooking range to install the hood turn off the power on an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE Figure 3 1 Puncture the knockout holes on the hood as shown in Figure 3 2 Using references on Table 1 and measurements on page 14 15 center the hood in place beneath the cabinet and flush with the front of the cabinet 3 Draw electrical wires through cabinet access opening 4 From the bottom of the hood place screw not provided into the exact center of each knockout hole Make sure all screws are in place before tightening screws CAUTION MAKE SURE THE HOOD IS SECURE BEFORE RELEASING 5 Make sure to leave this manual for the homeowner Plastic Exhaust 7 Round adapter 2 Ductwork Installation Figure 5 6 Use aluminum or steel pipe to connect the plastic exhaust on the hood to the duct
16. nections underneath the hood SEPARATE Make sure wires do not slip between motor or any moving parts to prevent any damage Duct Cover Installation 5 Use aluminum steel pipe to connect the plastic exhaust on the hood to the ductwork above Use duct tape to make DEENEN TIIN all joints secure and air tight as shown on Figure 13 6 To convert ductwork to 7 round attached 7 round adapter provided to the 6 round plastic exhaust 7 For 48 hood prepare either separate parallel connection or upside down Y Connection for proper ductwork installation Refer to Figure 14 7 Round Adapter 8 Slide the duct cover onto the hood Figure 15 Attach screws from underneath the hood to the duct cover Install Accessories 9 Refer to Figure 15 Slide the baffle filter into the hood Q Push the baffle filter upward Slide forward Pull downward Fit into place 10 For bottom casing repeat above steps Refer to page 15 Final Assembly 11 Turn power ON in control panel Check all lights and fan operation 12 Make sure to leave this manual for the homeowner 10 OPERATION INSTRUCTIONS This 15 equipped with four electronic controls with a 10 second standby startup amp 30 second delay shutoff powerful centrifugal squirrel cage with baffle filters and bright 12 volt 20 watt halogen lights The four electronic controls are Light Control S
17. not to damage electrical wiring or other hidden utilities 3 Ducted fans must be vented to the outside a Before servicing or cleaning unit open the light panel and SWITCH POWER OFF AT SERVICE PANEL b Clean fan baffles filters and grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust air into wall spaces attics crawl spaces or garages NOTE This warranty is invalid without an authorized agent s receipt or if unit is damaged due to misuse poor installation improper use mistreatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood WARNING TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE TOP GREASE FIRE 1 Keep fan baffle filter if any and grease laden surfaces clean 2 Always turn hood ON when cooking at high heat 3 Use high settings on cooking range ONLY when necessary Heat the oil slowly on low to medium setting 4 Do notleave cooking range unattended when cooking 5 Always use cookware and utensils appropriate for the type and amount of food prepared 6 Use this
18. nufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and code authorities Activating any switch on may cause ignition or an explosion WARNING CONUM amp ELECTRICAL SHOCK HAZARD Can result in serious injury or death Disconnect appliance from electric power before servicing If equipped the fluorescent light bulb contains small amounts of mercury which must be recycled or disposed of according to Local State and Federal Codes COMPONENTS OF PACKAGE Must keep all material for returns or refunds RANGE HOOD BOX ORIGINAL KIT Sold Separately Q KOBE Range Hood 1 Option of Warranty Registration Card 1 Instructions Manual 1 Baffle Filter 2 for 30 36 42 hood Model No CH0030DC 12 for 30 hood KOBE Duct Cover 1 3 for 48 hood 1 Screw Package 1 Bottom Casing 1 for 30 hood Hood Mounting Bracket 2 3 for 36 amp 42 hood 2 for 48 hood No CH0036DC 12 36 hood Screw Package 1 O Hood Mounting Bracket 2 Model No CH0042DC 12 for 42 hood KOBE Duct Cover 1 Screw Package 1 O Hood Mounting Bracket 2 Model No CH0048DC 12 for 48 hood KOBE Duct Cover 1 Q Screw Package 1 O Hood Mounting Bracket 2 OPTIONAL REC
19. peed Control A Speed Control B and the Power Control On Off Refer to Figure 16 Figure 16 Light Control Power Control Speed Control Speed Control B TURN ON e Press Power Control On Off button once Note If any Control button is not pressed within 10 seconds power will be automatically turned off e The KOBE hood will start on Low speed Each press of the Speed Control button will cycle through the various speeds e Press Speed Control A button to cycle from Low Medium High or QuietMode Press Speed Control B button to cycle from Low QuietMode High or Medium Note Speed Control or B will operate both fans These two speed buttons will allow you to change the speed quicker e Press Light Control button to turn halogen light on e Press the back Red button to turn on heating lamp Note Heating lamps are sold separately Heating lamps required 120 volt 250 watt 500 watt TURN OFF e Press Power Control On Off button once panel lights will flash and power will be completely shut off after 30 seconds OR e Press Power Control On Off button twice all power will be shut off immediately e If only the lights are on pressing Power Control On Off button once will turn power off after 30 seconds 11 MAINTENANCE For the optimal level of operation clean the range hood surface and baffles regularly To Clean Hood Surface CAUTION NEVER USE ABRASIVE CLEANERS PADS OR CLO
20. ust be notified in writing of any damages and or missing parts within the allocated days upon receipt of package s Contact your local KOBE dealer or distributor or call KOBE for the time limit CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS NOTE ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR FACTORY Products must be returned in good working condition with ALL original parts and documentation packed in ALL original cartons fillers and shipping cartons restocking fee of 25 will be charged for all approved return s EXCHANGES OR RETURNS MAY NOT BE ACCEPTED IF ANY PACKAGING IS MISSING MAKE SURE TO INSPECT THE HOOD FOR DAMAGES AND DEFECTS BEFORE INSTALLATION Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchanges Service visits not covered under warranty will carry a service charge A Before Installation Return for exchange or refund please see above for acceptable returns B After Installation NO exchange or refund 23 WARRANTY WARRANTY CERTIFICATE KOBE Range Hoods Inc warrants all products manufactured or supplied by it to be free from defects in workmanship and materials Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement at its option and subject to the terms and conditions stated below of any component part which its e
21. work above Use duct tape to make all joints secure and air tight as shown on Figure 4 7 To convert ductwork to 7 round attached 7 round adapter provided to the 6 round plastic exhaust SEPARATE 8 For 48 hood prepare either separate parallel connection or upside down Y connection for proper ductwork installation Refer to Figure 5 Wiring to Power Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK THIS RANGE HOOD MUST BE PROPERLY GROUNDED MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES BEFORE CONNECTING WIRES E waqa gapi SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY 9 Connect the electrical wires Connect three wires black white and green to house wires and cap with wire connectors Connect according to color black to black white to white and green to green as shown on Figure 6 If necessary to hide the electrical wire connections push wires back into the wiring box Access the wire connections underneath the hood Make sure wires do not slip between motor or any moving parts to prevent any damage Install Accessories 10 Refer Figure 7 Slide the baffle filter into the hood Push the baffle filter upward 9 Slide forward Pull downward Fit into place 11 For bottom casing repeat above steps Refer to page 15 UPSIDE DOWN Y CONNECTI
22. xamination shall disclose to be so defective TWO YEAR WARRANTY SERVICE PERIOD Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired or at our option the unit will be replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as applicable Keep proof of purchase or original invoice handy for inspection If the range hood is sold by the original purchaser during the warranty period the new owner is protected until expiration of the original purchaser s warranty CONDITIONS The following conditions apply only in relation to the warranty expressly given in this certificate 1 This warranty applies only a within U S A and Canada b to range hoods used for PRIVATE SINGLE FAMILY USE if used for COMMERCIAL or MULTIPLE FAMILY USE or other purposes warranty will be voided 2 Repair of any fault to be provided under this warranty shall not be provided a if the identification number attached to the range hood has been altered rendered illegible or removed b if notice of the defect has not been given within the period applicable C for failure of light bulbs d for physical damage e for surfaces damaged by use of improper chemical cleaning agents f ifthe appliance has been i subject to misuse abuse negligence accident incorrect installation or failure to follow the operating instructions ii conn

Download Pdf Manuals

image

Related Search

Related Contents

  clicca qui per il Impianto Viale Francia 6  V-Mouse 200 User Manual - Salient Technology  INSTRUCTION MANUAL MANUEL D`UTILISATION  Fellowes SB-89Ci  Z87 Extreme4 - Ingram Micro  TRACTOR AGRÍCOLA - Universidade de Évora  

Copyright © All rights reserved.
Failed to retrieve file