Home
Kidde KN-COPP-3 User's Manual
Contents
1. Possible Sources of Carbon Monoxide Inside your home appliances used for heating and cooking are the most likely sources of CO Vehicles running in attached garages can also produce dangerous levels of CO CO can be produced when burning any fossil fuel such as gasoline propane natural gas oil and wood It can be produced by any fuel burning appliance that is malfunctioning improperly installed or not ventilated correctly such as e Automobiles furnaces gas ranges stoves gas clothes dryers water heaters portable fuel burning space heaters and generators fireplaces wood burning stoves and certain swimming pool heaters e Blocked chimneys or flues back drafts and changes in air pressure corroded or disconnected vent pipes loose or cracked furnace exchangers e Vehicles and other combustion engines running in an open or closed garage attached or near a home e Burning charcoal or fuel in grills and hibachis in an enclosed area 1 Information About Carbon Monoxide Conditions That Can Produce Carbon Monoxide The following conditions can result in transient CO situations Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as wind direction and or veloci ty including high gusts of wind heavy air in the vent pipes cold humid air with extended periods between cycles e Negative pressure resulting from the use of exhaust fans e Simultaneous oper
2. s SIGNALING r g Kidde Carbon Monoxide Alarm User s Guide Model KN COPP 3 900 0076 LISTED Ag Kidde Carbon Monoxide ALARM KN COPP 3 with Digital Display S R e 120V AC e 9V Battery Backup e Peak Level Memory N A ATTENTION Please take a few minutes to thoroughly read this user s guide which should be saved for future reference and passed on to any subsequent owner Manual P N 820 1388 Rev C 07 12 2507 7229 01 What to do When the Alarm Sounds Carbon Monoxide Alarm Procedure WARNING Activation of the CO Alarm indicates the presence of Carbon Monoxide CO which can kill you Operate the Test Reset button Call your emergency services Fire Department or 911 PHONE NUMBER mmediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for Do not reenter the premises nor move away from the open door window until the emergency services responders have arrived the premises have been aired out and your alarm remains in its normal condition After following steps 1 3 if the alarm reactivates within a 24 hour period repeat steps 1 3 and call a qualified appliance technician to investigate sources of CO from fuel burning equipment and appliances and to inspect for proper operation of equipment PHONE NUMBER If problems are identified during this inspection have the equip ment serviced immedia
3. liability hereunder is limited to replacement of the product repair of the product or replacement of the product with repaired product at the discretion of the manufacturer This warranty is void if the product has been damaged by accident unreasonable use neglect tampering or other causes not arising from defects in material or workmanship This warranty extends to the original consumer purchaser of the product only Warranty Disclaimers Any implied warranties arising out of this sale including but not limited to the implied warranties of description merchantability and fitness for a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liability in tort or otherwise The Manufacturer shall have no liability for any personal injury property damage or any special incidental contingent or consequential damage of any kind resulting from gas leakage fire or explosion Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of consequential or incidental damages so the above limitations or exclusions may not apply to you Legal Reme
4. of the following approved brands e Duracell MN1604 or MX1604 e Energizer 522 e Gold Peak GP1604A These batteries can be purchased where you bought the alarm or at a local hardware store Use of a different battery may have a detrimental effect on the alarm operation The 9 volt battery is not rechargeable If the 9 volt battery is missing disconnected or if the battery s power is low Lb will be displayed alternately with the current CO reading once every second accompanied by an audible beep every 15 seconds If this happens the battery must be replaced To replace battery Remove back door by sliding it down and out Remove battery by unsnapping it from the battery clip Do not disconnect the battery by pulling the battery with one hand and the alarm with the other as this may break the wires connecting the battery to the CO alarm and void the warranty Install a new battery by connecting it to the battery clip and place into the recessed battery cavity Reinstall the back door of the unit IMPORTANT Constant exposures to high or low humidity may reduce battery life A good safety measure is to replace the battery at least once a year or at the same time as you change your clocks for daylight saving time After installing or changing the battery reinstall your alarm Test your alarm by using the Test Reset button and check that the display is on Maintenance Tips To keep your alarm in good working order you mus
5. the wall and insert the plastic anchors provided nstall the two screws provided into the wall or wall WALL anchors until the screw head is approximately 1 8 rom the wall 7 Hook the unit over the screw head and into the key hole in back of the unit 1 8 _ 8 Plug the adapter into an unswitched wall socket Screw Head Distance from Wall You can use your Kidde CO alarm as a table top unit Follow steps 1 thru 3 above Instead of mounting the unit to a wall pull out the slide support and place in a location that is easily visible Be sure the alarm is no more than three feet from the floor The alarm does not have to be within three feet from the floor to detect CO but at this height it is less likely to sustain damage from a fall Table Top Alarm 4 Installation Instructions Important Labels Provided Two labels have been provided that have important information on what to do in case of an alarm Add the phone number of your emergency service provider in the space provided Place one label next to the alarm after it is mounted and one label near a fresh air source such as a door or window 5 Alarm Characteristics Carbon Monoxide Alarm Indicator When the alarm senses a dangerous level of CO the unit will emit a loud alarm pattern The alarm pattern is 4 quick beeps followed by 5 seconds of silence This cycle repeats as long as a dangerous CO condi tions exist The red Alarm LED wi
6. FOR MORE INFORMATION Call our Product Support Line at 1 800 880 6788 or contact us at our website at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302
7. alarm for sideways outlet 4 Rotate the adapter 90 to the right clockwise Snap it firmly back into place v Carefully replace the back door Insure the latches on all four cor ners of the door are lined up then press the door securely into place oO Plug the alarm into an unswitched wall socket 4 Installation Instructions Wall Mounted Alarm Installation tips for power cord models The power cord option provides more flexibility in mounting locations and allows the alarm to be easily installed at eye level For a wall mounted unit you will need to pull out the removable adapter and power cord To install 1 Follow steps 1 through 3 in the previous sec tion under To Rotate the Adapter 2 With the adapter removed pull the power cord out of the cord storage remove the twist tie and extend the power cord 3 With the power cord extended press the last ew inches of the power cord into the cord recess Gently pull the cord at the bottom of the cord recess until the cord becomes taught and ays flat in cord recess 4 Carefully replace the back door Insure the latches on all four corners of the door are Back of alarm when ined up then press the door securely into place used as a wall mount unit 5 Mark the location for the two mounting holes on the wall spaced vertically 2 5 8 apart 6 If you are mounting the alarm in plaster board or drywall drill a 3 16 hole into
8. ation of several fuel burning appliances competing for limited internal air e Vent pipe connections vibrating loose from clothes dryers furnaces or water heaters e Obstructions in or unconventional vent pipe designs which can amplify the above situations e Extended operation of unvented fuel burning devices range oven fireplace etc e Temperature inversions which can trap exhaust gases near the ground e Vehicle idling in an open or closed garage or near a home To be safe know the possible sources of CO in your home Keep fuel burning appliances and their chimneys and vents in good working condi tion Learn the early symptoms of exposure and if you suspect CO poi soning move outside to fresh air and get emergency help Your first line of defense is an annual inspection and regular maintenance of your appliances Contact a licensed contractor or call your local utility compa ny for assistance Information About Carbon Monoxide Alarms What They Can and Cannot Do CO alarms provide early warning of the presence of CO usually before a healthy adult would experience symptoms This early warning is possible however only if your CO alarm is located installed and maintained as described in this guide Because carbon monoxide is a cumulative poison long term exposures to low levels may cause symptoms as well as short term exposures to high levels This Kidde unit has a time weighted alarm the higher the level
9. ay be present in other areas Important Warning Statements A WARNING This product is intended for use in ordinary indoor locations of family living units It is not designed to meas ure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards It is not suitable for installation in hazardous locations as defined in the National Electric Code The installation of this device should not be used as a substitute for proper installation use and maintenance of fuel burning appliances including appropriate ventilation and exhaust sys tems It does not prevent CO from occurring nor can it solve an existing CO problem A WARNING This device is designed to protect individuals from acute effects of carbon monoxide exposure It may not fully safe guard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30 PPM This carbon monoxide alarm requires a continuous supply of elec trical power it will not work without power Models without battery backup will not operate during power failure This alarm has not been investigated for carbon monoxide detec tion below 70 PPM Contents of This User s Guide 1 Information About Carbon Monoxide Product Features and Specifications Installation Locati
10. d begin monitoring the air for CO and will continue to do so as long as it receives power The following table illustrates the possible digital displays describes the audible alarm patterns and the recommended actions to take Operating and Alarm Characteristics LED Display Shows Alarm Sound Unit Status Recommendation 4 quick beeps Alarm condition Dangerous concentrations of CO detected Refer to What to do When the Alarm Sounds inside front cover A display of CO concentration from 5 seconds 30 999 silence repeating alalam Brief 888 along 4 quick beeps mimm with any number 5 seconds between 100 and 300 silence repeated once Self checking when AC powered Test button was pressed or unit was first None CO has not been detected Numbers shown for test purposes only powered mm Steady 0 displayed None Normal AC None u operation sensing no CO and with a good battery me Lb flashes One quick AC powered and Install or replace 9V e alternately with beep every low or missing battery any number 15 seconds battery f Steady Err displayed One quick Unit malfunction Replace battery If Err E beep every continues unit has 30 seconds malfunctioned and must be replaced immediately Unit will not respond to CO Press the Peak Level button while unit is in Err mode to obtain error code and call Product Support Line No display a with disp
11. dies This warranty gives you specific legal rights and you may also have other rights that vary from state to state Warranty Performance During the above warranty period your product will be replaced with a comparable product if the defective product is returned in a postage paid package to the following address Kidde Customer Service Department 1016 Corporate Park Drive Mebane NC 27302 USA together with proof of purchase date Please include a note describing the problem when you return the unit The replacement product will be in warranty for the remainder of the original warranty period or for six months whichever is longer Other than the cost of postage no charge will be made for replacement of the defective product In many cases the quickest way to exchange your alarm is to return it to the original place of purchase If you have questions call Kidde customer service department IMPORTANT Do not remove unit back cover Back cover removal will void warranty Your Kidde Carbon Monoxide Alarm is not a substitute for property disability life or other insurance of any kind Appropriate insurance coverage is your responsibility Consult your insurance agent Also Kidde makes no warranty express or implied written or oral including that of merchantability or fitness for any particular purpose with respect to the battery The above warranty may not be altered except in writing signed by both parties hereto QUESTIONS OR
12. e two distinctly different situations If your smoke alarm were to alarm you would quickly be able to judge the level of danger you were in with your senses You can see and smell the smoke feel the heat see and possibly hear the fire burning You can also readily see if your smoke alarm is alarming in a non emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smoke alarm CO is an invisible odorless tasteless and non irritating gas completely undetectable to your senses That s why it is important to your safety that you have a CO alarm Important Warning Statements IMPORTANT This carbon monoxide alarm is designed to detect carbon monoxide from ANY source of combustion It is NOT designed to detect smoke fire or any other gas A WARNING Carbon monoxide alarms are not smoke alarms This carbon monoxide alarm is not a substitute for installing and maintaining an appropriate number of smoke alarms in your home This carbon monoxide alarm will not sense smoke fire or any poisonous gas other than carbon monoxide even though carbon monoxide can be generated by fire For this reason you must install smoke alarms to provide early warning of fire and to pro tect you and your family from fire and its related hazards CAUTION This alarm will only indicate the presence of carbon monoxide at the sensor Carbon monoxide m
13. ition that may appear today and never reappear Some CO conditions may start out as low level leaks but could develop into CO concentrations that may become harmful Peak Level Memory Reset Press the Peak Level button with the button still pressed press the Test Reset button for two seconds and release The number on the dis play will turn to 0 the memory will be cleared and the alarm will begin monitoring for CO The Peak Level memory is also reset when the unit loses power NOTE This unit is sealed The cover is not removable Due to the loudness of the alarm we suggest that you place your fingers over the sounder opening while testing your alarm Caution Continuous exposure to the high sound level of this alarm over an extended period of time may cause hearing loss Testing To test the alarm press the Test Reset button If the unit is operating properly you will hear 4 quick beeps followed by 5 seconds of silence followed by 4 quick beeps The display will show three eights and then show a number usually around 200 Within several seconds the unit will return to monitor for CO Note You do not need to press the Test button to take a CO read ing Battery Replacement NOTE This CO alarm is not battery operated However these alarms are equipped with 9 volt battery backup the 9 volt battery is to supply short term back up during a power outage When replacing the battery use one
14. lay concentratio mu d f aa seconds ternating of CO 5 seconds n every 60 silence repeating every 60 secs 4 quick beeps Alarm condition powered on battery backup Dangerous concentrations of CO detected Refer to What to do When the Alarm Sounds inside front cover Replace battery ternating None No display al with 0 every 60 seconds Normal operation after first 4 minutes of 9 V battery operation Unit monitoring for CO Verify AC power is restored as soon as possible to conserve battery Replace battery mm End disp m a a jayed Two quick beeps End of unit life every 30 seconds Replace unit immedi ately Unit will not respond to CO 6 Model KN COPP 3 Operating Characteristics Peak Level Memory When the Peak Level button is pressed and held the display shows the highest CO reading taken by the CO alarm since its last reset or power up The Peak Level display feature will display levels between 11 999 PPM Although the Peak Level feature will display levels below 30 PPM these levels will not result in an alarm no matter how long the device is exposed to these levels The Peak Level feature is helpful in identifying if you have had a CO reading since resetting the alarm Concentrations of CO between 1 and 30 PPM can often occur in nor mal everyday conditions Concentrations of CO below 30 PPM may be an indication of a transient cond
15. ll flash the same pattern and the PPM will be displayed on alarms with digital displays N WARNING When powered by battery backup only after four min utes the alarm will sound and flash only once every minute until the alarm is reset or the CO is eliminated If the battery is low or missing or if the unit malfunctions it will display other readings and alarm differently to alert you of specific conditions Please familiarize yourself and other family members to the difference between a CO reading and and indication signifying a problem with the unit itself A WARNING If at any time you test the alarm and it does not perform as described have it replaced immediately 6 Model KN COPP 3 Operating Characteristics Whenever the alarm is operating the digital display will display 0 to indicate the unit is monitoring for CO If the alarm senses dangerous lev els of CO the digital display will indicate the CO concentration in parts per million PPM and the alarm will emit an audible alarm pattern This alarm will display a O if CO concentrations between 0 and 30 PPM have been detected within the last 15 seconds When the unit is first powered up the digital display will show three eights indicating the alarm is in the start up mode The three eights will remain for approximately 20 seconds After 20 seconds 6 Model KN COPP 3 Operating Characteristics the alarm should display O an
16. m Replace the alarm immediately It will not detect CO in this condition To help identify the date to replace the alarm a label has been affixed to the side of the alarm Write the replace by date ten years from power up in a permanent marker on this label 2 Product Features and Specifications Temperature Operating Range 40 F 4 4 C to 100 F 37 8 C Humidity Operating range 10 95 non condensing Audible Alarm 85 dB at 10 3 4 0 5 KHz pulsing alarm Sensor Electrochemical Power 120 volts AC 60 Hz 60 mA max 9 volt battery back up Accuracy of Digital Display 30 999 PPM 30 when measured in conditions of 80 F 10 F atmospheric pressure 10 and 40 3 relative humidity Display readings may vary slightly depending on changes in the ambient condition temperature humidity and the condition of the sensor Alarm Response Times 70 PPM 60 240 min 150 PPM 10 50 min 400 PPM 4 15 min 3 Installation Locations Recommended Installation Locations CO alarms should be mounted in e or near bedrooms and living areas DINING KITCHEN BEDROOM BEDROOM It is recommended that you install a Kidde CO alarm on each level of your home e BEDROOM When choosing your installation locations make sure you can hear Recommended Locations the alarm from all sleeping areas If you install only one CO alarm in your home install it near bedrooms not in the basement o
17. nd not reach a CO alarm installed on a different level For example CO in the basement may not reach an alarm on the second level near the bedrooms For these reasons we recommend you provide complete coverage by placing a CO alarm on every level of the home Please carefully read all information on properly installing this CO alarm CO alarms should not be used to detect the presence of natural gas methane propane butane or other combustible fuels Instruct children never to touch unplug or otherwise interfere with the alarm Warn children of the dangers of CO poisoning 2 Product Features and Specifications Eide Model KN COPP 3 Digital Display Blinking with digital display Red Dot TEB Test Reset Peak Level Button O l j Button Adapter Thumb Release Lm Wt SI S S Alarm bza 4 Sounder Back Bi Removable Door O AC Adapter g L Key 9V Backup Holes Battery shown installed 6 Cord Storage Slide Support for Table Top and Direct Plug Use Power Cord 7 Install Backup Battery Cord as shown Recess IMPORTANT Ten 10 years after the initial power up this alarm will beep two times every 30 seconds to indicate that it is time to replace the alar
18. of CO present the sooner the alarm will be triggered 1 Information About Carbon Monoxide This CO alarm can only warn you of the presence of CO It does not prevent CO from occurring nor can it solve an existing CO problem If your unit has alarmed and you ve provided ventilation by leaving your windows and doors open the CO buildup may have dissipated by the time help responds Although your problem may appear to be temporarily solved it s crucial that the source of the CO is determined and that the appropriate repairs are made This CO alarm is designed to act as a monitor it is not designed for use as a short term testing device to perform a quick check for the presence of CO CO alarms have limitations Like any other electronic device CO alarms are not fool proof CO alarms have a limited operational life You must test your CO alarm weekly because it could fail to operate at any time If your CO alarm fails to test properly or if its self diagnostic test reveals a malfunction immediately have the unit replaced This alarm will not monitor CO levels while in an error condition CO alarms can only sense CO that reaches the unit s sensor It s possible that CO may be present in other areas without reaching the alarm The rate and ability that which CO reaches the alarm may be affected by e Doors or other obstructions e Fresh air from a vent an open window or other source e CO being present on one level of the home a
19. ons Installation Instructions Alarm Characteristics KN COPP 3 Operating Characteristics Maintenance SO Oy OT Bs Gd Limited Warranty 1 Information About Carbon Monoxide General Carbon Monoxide Information Carbon monoxide is a colorless odorless and tasteless poison gas that can be fatal when inhaled CO inhibits the blood s capacity to carry oxy gen Periodically review this user s guide and discuss your CO alarm emer gency procedure with all the members of your family Never ignore a CO alarm A true alarm is an indication of potentially dangerous levels of CO CO alarms are designed to alert you to the presence of CO before an emergency before most people would experience symptoms of CO poisoning giving you time to resolve the problem calmly Determine if anyone in the household is experiencing symptoms of CO poisoning Many cases of reported CO poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and household pets may be the first affected You should take extra precautions to protect high risk persons rom CO exposure because they may experience ill effects from CO at evels that would not ordinarily affect a healthy adult Symptoms of CO Poisoning The following common symptoms are related to CO poisoning and should be discussed with ALL members of the h
20. ousehold Mild Exposure Slight headache nausea vomiting fatigue often described as flu like symptoms Medium Exposure Severe throbbing headache drowsiness confusion fast heart rate Extreme Exposure Unconsciousness convulsions cardio respiratory failure death If you experience even mild symptoms of CO poisoning consult your doctor immediately Carbon Monoxide PPM Levels Model KN COPP 3 is equipped with a digital display that shows levels of CO displayed in PPM parts per million Learn the difference between dangerous high mid and low levels 1 Information About Carbon Monoxide Dangerous Levels When someone is experiencing symptoms of CO poisoning and CO readings are generally above 100 PPM Anytime someone is experiencing the symptoms of CO poisoning this should be treated as an emergency See What to do When the Alarm Sounds inside front cover High Levels Generally above 100 PPM with no one experiencing symptoms This should be treated as an urgent situation See What to do When the Alarm Sounds inside front cover Mid Levels Generally between 50 PPM to 100 PPM This should be cause for concern and should not be ignored or dismissed See What to do When the Alarm Sounds inside front cover Low Levels Generally below 50 PPM Kidde recommends you take action to eliminate the source of CO See What to do When the Alarm Sounds inside front cover
21. r furnace room 3 Installation Locations e When wall mounting place out of reach of children Under no cir cumstances should children be allowed to handle the CO alarm e Placing the alarm at eye level allows for optimum monitoring of the digital display Locations To Avoid IMPORTANT Improper location can affect the sensitive electronic com ponents in this alarm To avoid causing damage to the unit to provide op imum per Do not ins he sensor Do not ins 4 4 C or Do not ins recommen Do not ins ventilation Do not ins Do not ins formance and to prevent unnecessary nuisance alarms all in kitchens garages or furnace rooms that may expose to substances that could damage or contaminate it all in areas where the temperature is colder than 40 F hotter than 100 F 37 8 C such as crawl spaces attics porches and garages within 5 ft of heating or cooking appliances Kidde s 15 ft to prevent nuisance alarms 2o all near vents flues chimneys or any forced unforced air openings all near ceiling fans doors windows or areas directly exposed to the weather all in dead air spaces such as peaks of vaulted ceilings or gabled roofs where CO may not reach the sensor in time to provide all on a switched or dimmer controlled outlet Do not ins alarm whe he vents all this unit near deep cell large batteries Large batteries have emissions that can cau
22. se the alarm to perform at less than opti mum performance Do not obstruct the vents located on the alarm Do not place the re drapes furniture or other objects block the flow of air to 4 Installation Instructions How to Install Your Alarm Your Kidde CO alarm with its removable adapter allows you to install the alarm as a wall mounted unit a direct plug unit or as a table top unit In its as shipped configuration all you need to do is install the 9V backup battery and your Kidde CO alarm is ready to be plugged directly Slide support into a wall socket N Direct Plug Alarm L les To install Back of alarm when 1 Choose a standard 120V unswitched outlet used as direct plug unit to plug the alarm into 2 Pull the slide support out approximately 1 4 until the slide snaps into place This will help support unit in the wall outlet 3 Plug the alarm into the outlet If the outlet is mounted horizontally side ways If you are going to use your alarm as a direct plug and you are going to plug in to an outlet that is mounted horizontally sideways you will need to rotate the adapter 90 To rotate the adapter 1 Remove back door by sliding it down and out 2 Spread adapter thumb releases out and care 2 fully turn alarm over This will allow adapter Back of alarm when to slide out used as direct plug unit 3 Lift the adapter completely out of the
23. t follow these steps e Test the alarm once a week by pressing the Test Reset button e Vacuum the alarm cover once a month to remove accumulated dust e Never use detergents or solvents to clean the alarm Chemicals can permanently damage or temporarily contaminate the sensor e Avoid spraying air fresheners hair spray paint or other aerosols near the alarm e Do not paint the unit Paint will seal the vents and interfere with proper sensor operation Move the CO Alarm to a remote location to prevent possible damage or contamination of the sensor prior to performing any of the following e Staining or stripping floors or furniture painting or wall papering e Using aerosols or adhesives A WARNING Reinstall the CO Alarm as soon as possible to assure continuous protection The following is a list of substances that at high levels can damage the sensor or cause temporary readings that are not CO readings e Ethylene ethanol alcohol iso propanol benzene toluene ethyl acetate hydrogen hydrogen sulfide and sulfur dioxide e Also most aerosol sprays alcohol based products paint thinner sol vent adhesive hair spray after shave perfume auto exhaust cold start and some cleaning agents End of Life Notification Ten 10 years after unit is first powered this alarm will beep two times every 30 seconds to indicate it is time to replace the alarm and End will show in the digital display Once the uni
24. t is in End of Life Notification mode the alarm will no longer detect the presence of CO FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harm ful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help TEN YEAR LIMITED WARRANTY Warranty Coverage The manufacturer warrants to the original consumer purchaser that this product except battery will be free of defects in material and workmanship for a period of ten 10 years from date of purchase The manufacturer s
25. tely Note any combustion equipment not inspected by the technician and consult the manufacturer s instruc tions or contact the manufacturer s directly for more information about CO safety and the equipment Make sure that motor vehicles are not or have not been operating in a garage attached or adja cent to the residence Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the test reset button will terminate the alarm If the CO condition that caused the alert in the first place continues the alarm will reactivate If the unit alarms again within six minutes it is sensing high levels of CO which can quickly become a dangerous situation Note Many times throughout this User s Guide we will refer to Carbon Monoxide as CO This Kidde carbon monoxide CO alarm is an important part of your family s home safety plan This alarm has been designed and tested to detect CO buildup in a residential environment Your alarm is for use specifically in the home As an owner of a CO alarm there are some basic facts you should know about for your protection Many people think that CO alarms operate like smoke alarms Like smoke alarms CO alarms monitor the air in your home and sound a loud alarm to warn you of trouble The way you respond to a CO alarm is quite different than a smoke alarm That s because a house fire and a CO problem ar