Home

Kenmore 30'' Electric Cooktop - Black Installation Guide

image

Contents

1. inches cm Allow 2 5 cm space below cooktop to clear the electric cable and allow for installation of the junction box on the wall at the back of the cooktop Printed in China P N 318205431 1311 Rev A English pages 1 8 Espafiol pages 9 16 Frangais pages 17 24 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximym Depth of 13 33 cm 30 76 2 cm Min Clearance Between 2 5 1 cm Min the Top of the Cooking Recommended Platform and the Bottom Distance Between of an Unprotected Rear Edge of i Wood or Metal Cabinet N Cutout and Nearest 10 Combustible Surface 129 4 cm Above Countertop 18 E lii b 45 7 cm 24 61 cm Min when Bottom of Wood or Metal Cabinet is Protected bv Not Less Than 1 8 Flame Retardant Millboard Covered With Not Less Than No 28 MGS Sheet Steel 0 015 0 4 mm Stainless Steel 0 024 0 6 mm Aluminum or 0 020 0 5 mm Copper 72 19 1 cm Min From Edge of Cooktop to Nearest Combustible Wall Either Side of Unit lt is not recommended to use drawer underneath cooktop Empty space is needed for 61 cm Approximate Location of Junction Box 272 6 4 cm Min From Edge of installation purpose Cutout to Front Edge of Countertop Letters on this figure refer to chart on front page except for I F TA WUXI To eliminate the risk of burns or fire by re
2. the neutral white wire the appliance frame MUST NOT be connected to the neutral wire of the 4 wire electrical system If your cooktop has a 3 wire cable see figure 6 1 2 3 Disconnect the power supply Separate the green or bare copper and white appliance cable wires Cap the white wire from the power supply cable if a 3 wire appliance cable is supplied In the circuit breaker fuse box or junction box connect appliance and power supply cable wires as shown in figure 6 Cable from Power Supplv White Wire Ground Wire Bare or Green Wire x en U L Listed Conduit n Connector or CSA listed Cable from appliance Figure 6 4 WIRE GROUNDED JUNCTION BOX If your cooktop has a 4 wire cable see figure 7 1 Disconnect the power supply 2 Separate the green or bare copper and white appliance cable wires 3 In the circuit breaker fuse box or junction box connect appliance and power supply cable wires as shown in figure 7 Cable from Power Supply Ground Wire Ground Wire Bare or Green Wire 7 UDisted Conduit Junction Box Connector or CSA listed Cable from appliance Figure 7 Models 36 with Warmer Zone 4 WIRE GROUNDED JUNCTION BOX If connecting to a 4 wire power supply cable electrical system the appliance frame connected ground wire MUST NOT be connected to the neutral wire of the 4 wire electrical system ELECTRIC COOKTOP INSTA
3. ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE U READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE GAS L US FOR VOUR SAFETV Do not store or use gasoline or other flammable vapors LISTED and liquids in the vicinity of this or any other appliance IMPORTANT INSTALLATION 30 76 2 cm min for unprotected cabinet INFORMATION 24 61 cm min for protected surface e All electric cooktops run off a single phase three wire or four wire cable 240 208 volt 60 hertz AC only electrical supply with ground e Please note minimum distance between cooktop and adjacent and overhead unprotected cabinetry is 30 76 2 cm a i _ Cooktop Dimensions 30 Min The corners A 76 2 cm of this unit are fragile Carefully install the cooktop by its sides When installing lo never let the weight of the 4 X 8 unit rest on any one corner se 10 2 cm x 20 3 cm opening at the right rear to route armored cable if a panel is present Cooktop Cutout Dimensions Figure 1 PRODUCT DIMENSIONS MODEL A WIDTH B DEPTH C HEIGHT C2 HEIGHT D BOX WIDTH E BOX DEPTH CUT OUT DIMENSIONS F WIDTH G DEPTH H HEIGHT BELOW MINIMUM MAXIMUM MINIMUM MAXIMUM COOKTOP 30 Ceramic Model 29 75 6 30 1 8 76 5 20 3 8 51 8 20 52 7 6 15 2 AII dimensions are in
4. LLATION INSTRUCTIONS Cooktop Installation 1 Visuallv inspect the cooktop for damage Also make sure all cooktop screws are tight see Figure 8 2 Install the retainer brackets See Figure 9 GP DD Figure 8 Screws The retainer brackets MUST be installed to meet local codes or in their absence with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA Standard C22 1 Canadian Electrical Code Part 1 see Figure 9 Cooktop Nylon spacer 8 18 x 3 8 Retainer bracket Figure 9 3 Set the cooktop into the countertop cutout NOTE Do not use caulking compound cooktop should be removable for service when needed F NZIIMEN Do not remove the nylon spacers on the edges of the cooktop These spacers center the cooktop in the space provided The cooktop must be centered to prevent excess heat buildup that may result in heat damage or fire see Figure 10 2 Nylon spacers I 2 Retainer brackets Figure 10 WARNING The corners of this unit are fragile Carefully install the cooktop by its sides When installing never let the weight of the unit rest on any one corner ni a Figure 11 Checking Operation Refer to the Use and Care Guide for operation NA UU Do not touch cooktop glass or elements They may be hot enough to burn you Model and Serial Number Location The serial plate is located under the cooktop When
5. aching over heated surfaces cabinet storage space 30 Model 30 76 2 cm located above the cooktop should be avoided If cabinet 36 Model 36 91 4 cm storage is provided risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Figure 2 COUNTERTOP CUTOUT OPENING ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Important Notes to the Installer 1 Read all instructions contained in these installation instructions before installing the cooktop 2 Remove all packing material before connecting the electrical supply to the cooktop 3 Observe all governing codes and ordinances 4 Be sure to leave these instructions with the consumer Important Note to the Consumer Keep these instructions with your Use and Care Guide for future reference IMPORTANT SAFETY INSTRUCTIONS e Be sure your cooktop is installed and grounded properly by a qualified installer or service technician e These cooktops must be electrically grounded in accordance with local codes or in their absence with the National Electrical Code ANSI NFPA No 70 latest edition in the United States or with CSA Standard C22 1 Canadian Electrical Code Part 1 in Canada PNIZGININE The electrical power to the cooktop must be shut off while line connections are being made Failure to do so could result in serious injury or death Provide Electrical Connection Install the junctio
6. e conductor is governed by the temperature rating of the insulation around the wire rather than the wire gauge alone Where local codes permit connecting the appliance grounding conductor to the neutral white wire If your cooktop has a 3 wire cable to be connected to a l 3 wire grounded junction box see figure 4 Disconnect the power supply 2 In the circuit breaker fuse box or junction box connect appliance and power supplv cable wires as shown in figure 4 Cable from Power Supplv White Wire Neutral Red Ground Wire E U L Listed Conduit Bare or Green Wire Connector or CSA listed Cable from appliance Figure 4 3 WIRE GROUNDED JUNCTION BOX If your cooktop has a 4 wire cable to be connected to 1 2 3 wire grounded junction box see figure 5 Disconnect the power supplv In the circuit breaker fuse box or junction box connect appliance and power supplv cable wires as shown in figure 5 Cable from Power Supplv White Wire Neutral f 4 Junction Box White Wire Neutral Ground Wire U L Listed Conduit Bare or Green Wire Connector or CSA listed Cable from appliance Figure 5 3 WIRE GROUNDED JUNCTION BOX 36 Models with Warmer Zone ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS If the appliance is used in a new branch circuit installation 1996 NEC mobile home recreational vehicle or where local codes DO NOT permit grounding through
7. e conduit Do not over bend or excessively distort flexible conduit to avoid separation of convolutions en exposure of internal wires DO NOT ground to a gas supply pipe DO NOT connect to electrical power supply until appliance is permanently grounded Connect the ground wire before turning on the power A WARNINGEG your appliance is equipped with a white neutral conductor This appliance is manufactured with a white neutral power supply and a frame connected copper wire The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit if used in USA in a new branch circuit installation 1996 NEC mobile home recreational vehicles where local code do not permit grounding trough the neutral white wire or in Canada disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch circuit neutral conductor in usual manner see Figure 6 or 7 If your appliance is to be connected to a 3 wire grounded junction box US only where local code permit connecting the appliance grounding conductor to the neutral white see Figure 4 or 5 NOTE TO ELECTRICIAN The armored cable leads supplied with the appliance are UL recognized for connection to larger gauge household wiring The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring The current carrying capacity of th
8. he flexible armored cable to the junction box Observe all governing codes and local ordinances Unpacking Instructions 1 Leave corner supports on cooktop until completion of Electrical Connection 2 Be sure the bottle of cleaner conditioner packed in the literature bag is left where the user can find it easily It is important that the ceramic glass smoothtop be pretreated before use See Ceramic Glass Cooktop Cleaning and Maintenance section in the Use and Care Guide Model and Serial Plate Under Cooktop Figure 3 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Electrical connection It is the responsibilitv and obligation of the consumer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA Standard C22 1 Canadian Electrical Code Part 1 and local codes and ordinances Risk of electrical shock Failure to heed this warning may result in electrocution or other serious injury This appliance is equipped with copper lead wire If connection is made to aluminum house wiring use only connectors that are approved for joining copper and aluminum wire in accordance with the National Electrical Code and local code and ordinances When installing connectors having screws which bear directly on the steel and or aluminum flexible conduit do no tighten screws sufficiently to damage the flexibl
9. n box under the cabinet and run 120 240 or 120 208 Volt AC wire from the main circuit panel NOTE DO NOT connect the wire to the circuit panel at this time Wait until all wires have been connected in the junction box Electrical Requirements Observe all governing codes and local ordinances 1 A 3 wire or 4 wire single phase 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line a 40A time delay fuse or circuit breaker is recommended DO NOT fuse neutral NOTE Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA standard C22 1 Canadian Electrical Code Part 1 and local local codes and ordinances PINEN An extension cord must not be used with this appliance Such use may result in a fire electrical shock or other personal injury 2 The appliance should be connected to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed cable The flexible armored cable extending from this appliance should be connected directly to the grounded junction box The junction box should be located as shown in Figure 2 with as much slack as possible remaining in the cable between the box and the appliance so it can be moved if servicing is ever necessary 3 A suitable strain relief must be provided to attach t
10. net s by mounting brackets 36 Min 91 4 cm Min sos A L A 208 240 Volt junction box for built in oven N x N Ni Da e y La I Pa PA Fa Pa Pa r Pa Use 34 1 9 cm plywood installed on two runners flush with toe plate Base must be capable of YI f supporting 150 pounds Unit will overlap cutout 68kg for 27 models and Cut an opening in wood base minimum 4 x 4 minimum 200 pounds 90kg for 10 2 cm X 10 2 cm 2 5 cm from left side edges by 1 AV 11 5 30 models filler panel to route armored cable to junction 2 5 cm l K a box cm Max If no cooktop is installed CUTOUT DIMENSIONS directly over the oven unit 5 12 7cm maximum is n WIDTH G DEPTH H HEIGHT allowed above the floor 27 68 6cm 247 s 63 2cm Min i 274 69 2cm Min Wall Oven 2514 64 1cm Max e a Oe 2814 71 8cm Max 30 76 2cm 282 72 4cm Min i 274 69 2cm Min Wall Oven 29 73 7cm Max PARATI 281 71 8cm Max Figure 12 TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Notes
11. ordering parts for or making inquiries about your cooktop always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your cooktop Before You Call for Service Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to your Use and Care Guide for Sears service phone numbers or call 1 800 4 MY HOME ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS For typical under counter installation of an electric built in oven see Figure below Only certain cooktop models may be installed Note 1 4 x 4 10 2 cm X 10 2 cm opening to route over certain built in electric oven models armored cable from cooktop to junction box Approved cooktops and built in ovens are listed by the MFG ID number and product code see the Cabinet side filler panels insert sheet included in the literature package and Approx 3 208 240Volt are necessary to isolate cooktop installation instructions for dimensions 7 5 cm junction box the unit from adjoining for cooktop cabinets Cabinet side filler height should allow for installation of approved cooktop models MA WARNING To reduce the risk of personal injurv and Approx 3 tipping of the wall 75 cm oven the wall oven must be secured to the cabi

Download Pdf Manuals

image

Related Search

Related Contents

Content - RCC ITALY  4Way Midi  CUID – INGLES ELEMENTAL (A1) Curso 2010 / 11  Toshiba M300 Personal Computer User Manual  Descargar manual  France - CRC Industries Europe  KitchenAid 9763388 User's Manual  (rus) инструкция по эксплутации.................2  Installation manual - VITRAL SkyVision Comfort  Istruzioni d`uso  