Home
Kenmore 625.34855 User's Manual
Contents
1. NOTE You will have a loss in softening capacity and may get partly hard water if less than 10 inches salt monitor level 2 of saltisin thestoragetank PLEASE SEE PAGE 9 FOR SALT FILLING DIRECTIONS BE SURE TO RESET THE SALT MONITOR PAGE 10 SALT BRIDGE Sometimes a hard crust or salt bridge forms in thesalt storagetank It is usually caused by high humidity or thewrong kind of salt When thesalt bridges an empty space forms between the water and salt Then salt will not dissolve melt in the water to make brine Without brine the resin bed does not regenerate and you will have hard water If thestoragetank isfull of salt itis hard totell if you haveasaltbridge Saltislooseontop butthe bridgeis under it Thefollowing isthe best way to check for a salt bridge Salt should beloose all the way to the bottom of thetank H old a broom handle or liketool up to the softener as shown in FIG 9 Make a pencil mark on thehandle 1xor 2 lt below thetop height of therim Then carefully push it straight down into the salt If a hard object is felt before the pencil mark gets to the top of the tank it s most likely a salt bridge Carefully push into the bridge in a few places to break it Do not try to break the salt bridge by pounding on the outside of the salt tank You may damage it 15 If thewrong kind of salt made the bridge takeit out Then fill the tank with nugget or pellet salt only push t
2. clear water iron See maximum allowed in the specifications on page 19 With clear water iron water from a faucet is clear when first put into a glass After 15 to 30 minutes the water begins to cloud or turn rust colored A water softener WILL NOT remove any iron which makes the water cloudy or rusty as it comes from the faucet called red water iron To take red water iron out of water or over themaximum of clear water iron an iron filter or 16 NOTE Never use cleaners having ammonia or abra sives They may scratch and dull the surface CLEANING THE NOZZLE amp VENTURI NW a Cao f O Ring A Screen ___ Support Flow Screen lug Nozzle amp d DVDC a Venturi Gasket ___ MN Flow Plug Hvo Nozz amp Vent Housing INSTALL WITH NUMBERED SIDE UP CONCAVE SIDE DOWN BE SURE THE FLOW PLUG WITH THE LARGEST CENTER HOLE IS LOCATED IN THE NOZZLE amp VENTURI HOUSING other equipment is needed Your local Sears store has trained people to help you with iron water problems If your water supply has clear water iron even though less than the maxi mum allow ed regular resin bed cleaning is needed Sears has resin bed cleaner Stock No 42 34426 for this Clean the bed at least every 6 months If iron shows up in the soft water before 6 months clean moreoften Printed instructions areon the resin bed deaner bottle SECTION 3 CARE OF YOU
3. On some water supplies the water softener may need pe riodic disinfecting water Salt Hole Brinewell Cover remove and add about 3 4 oz bleach Brinewell Water About 3 Gallons SECTION 1 WATER SOFTENER START UP 1E FILL THE STORAGE TANK WITH SALT Brine salt dissolved in water is needed for each and every regeneration The water for making brineis metered into the salt storagetank by the softener H owever you must keep thetank fill ed with salt Fill the tank with NUGGET or PELLET water softener salt DO NOT use rock salts as they have dirt and sediments that will stop the softener from working Before filling be sure the brinewell cover is in place on the top of the brinewell Salt storage capacity is shown on page 19 Be sure to set the salt monitor system see page 10 NOTES Thesalt monitor system page 10 is calibrated to the density of nugget or pellet water softener salt The monitor will not work as accurately with other types of salt including rock and solar In humid areas it is best to fill the storage tank half full and to refill it more often Salt bridging see page 15 occurs more often when conditions are humid WATER SOFTENING SALT WITH IRON RE MOVING ADDITIVES Some salts have an additive to help the softener handle iron in the water supply Although this additive may help to keep the softener resin clean it may also release corrosive fumes that
4. chips or wear NOTE If replacementis needed be sure to use the current replacement part ASSEMBLY Be sure all parts are in place and in the proper position Lubricate ALL o rings and seals with FDA approved silicone grease To install the rotor seal first place the seal into the valve groove rounded side down see cross section Apply a light coating of silicone grease to the seal s crossing ribs Then carefully center the wear strip on the seal and push it downward onto the seal Install the nozzle and venturi seal and drain seal Assemble 2 o rings and the wave washer onto the rotor and disc Then center the rotor and disc in the valve body on the rotor seal 2A ROTARY VALVE SERVICE Lower the cover onto the valve body and rotor shaft Then install the cover holding screws Before tightening the screws install the valve cam and gear Then turn the rotor clockwise only to service position Tighten the screws using a criss cross pattern If a torque wrench is available torque to 30 40 inch pounds Switch P F valve cam ie o Wis SEE NOZZLE ASSEMBLY SERVICE flow plug backwash PAGE 16 amp and fast rinse flow lt rate control screen support a rotor amp disc ae LF screen o ring nozzle amp venturi gasket c Win CSS rotor seal flow plug 2 gt 2x2 i NS 2 rain seal 77779 nozzle
5. 2 ea of Key No 50 7090705 Screen 0900857 Screw 6 20 x 3 8 2 req 7089893 Screen Support 7117808 Motor Plate 7039068 O Ring 3 8 x 1 3 8 0503288 Bearing 7081188 Cap 7113927 Cam and Gear 7084607 Flow Plug 15 gpm 7142942 Drain 9001006 O Ring 3 3 8 x 3 5 8 0501228 Flow Plug 7103964 Rotor amp Disc 0900041 O Ring 5 8 x 13 16 7082087 Wave Washer 7024160 Drain Hose Adaptor 7064372 O Ring 3 4 x 15 16 0900431 Hose Clamp 6A 7064380 O Ring 7 16 x 5 8 7116713 Clip 2 req 6A 7085263 Valve Cover 0507369 Installation Nut 2 req A 7074123 Screw 10 14 x 2 5 req 0507615 Installation Tube 2 req A 7077472 Expansion Pin 0900570 Washer 2 req A 7030713 Switch 42 3441 Install Kit incl Key Nos 62 63 amp 64 1 7117816 Spacer 0507371 Installation Adaptor 2 req 7070412 Screw 44 24 x 1 1 8 flat head 0900535 O Ring 15 16 x 1 3 16 2 req 7097171 Sensor Housing 7134224 Rotor Seal 2204101 Turbine S upport and Shaft 7092634 O ARing 3 8 x 9 16 7117858 Turbine 7092642 Plug Drain Seal 9000803 O Ring 1219600 Spring 7137507 Nozzle amp Venturi Assy incl Key 7081764 Seal Nozzle amp Venturi Nos 75 and 78 through 84 7082053 Valve Body 7144813 Bag Model 625 3485400 0900064 O Ring 1 4 x 3 8 2 req incl parts marked with a pages 7081201 Retainer Nozzle amp Venturi 28 29 amp 31 order manuals sepa rately
6. RECHARGE NOW Press the ON OFF H OLD button and hold until RECHARGE NOW SERV and FILL begin to flash in the display Upon reaching fill the first cycle of regen eration the flashing SERV goes off and FILL is on steady RECHARGE NOW continues to flash This re generation will last for about 2 hours After the 2 hours you will have soft water again RECHARGE TONIGHT Press and release do not hold the ON OFF HOLD button RECHARGE TO NIGHT flashes in the dis play and the softener be gins regeneration at the next preset recharge time Press and release the ON OFF HOLD button once moreif you decideto cancel the regeneration and RE CHARGE TONIGHT 10 SALT MONITOR SYSTEM The face plate timer has alow salt monitor with an indicator light to remind you to refill the storagetank with salt To setthis monitor system 1 Liftthesalt holecover and level thesaltinthe storage tank 2 The salt level decal on the brinewell inside the tank has numbers from 0 to 8 see drawing on page 9 and below Observe the number the leveled salt is at or closest to NOTE To light the salt storage area press the TANK LIGHT button on the face plate 3 Now presstheSALT LEVEL ADJUST button until black bars display up to the salt level number For example the pictures below show the salt level at 6 4 Finally set the level you want the low salt indicator light to come on Press the SIGNAL LIGHT ADJUST button
7. SERVICE TECH INFORMATION 5C WATER FLOW THROUGH THE SOFTENER VALVE BRINING AND BRINE RINSE CYCLES ROTOR amp DISC VENTURI VALVE INLET HARD WATER BRINE gt POSITION 7 7 UM x e iz e i y SWITCH After fill timer switch action allows the motor to turn the rotor and disc into BRINING position Water flow is directed to the nozzle Suction created by the nozzle and venturi draws brine from the salt storage tank and injects itinto the resin bed via the bottom distributor Flow continues out the top distributor and to the drain Hard water is available at the valve outlet When the brine valve closes to end brine draw water flow continues in the same directions to slowly RINSE brine from the resin bed and to the drain BACKWASH CYCLE FLOW PLUG ROTOR amp DISC Timer switch action again allows the motor to turn the rotor amp disc to place the valve in BACKWASH stopping water flow to the nozzle Water is routed down and out the bottom distributor up through the bed and outthe top distributor to the drain The fast flow controlled by a flow plug in the drain fitting flushes dirt sediments iron deposits remaining brine and hardness to the drain DISTRIBUTOR 26 SECTION 5 SERVICE TECH INFORMATION 5C WATER FLOW THROUGH THE SOFTENER VALVE FAST RINSE CYCLE ROTOR amp DISC POSITION Me E ESI VALVE INLET
8. is needed When starting the softener page 7 you set it for the grains per gallon gpg hardness of the water To find a regeneration pattern best for your needs the computer uses 1 water usage from the meter 2 hardness setting 3 softener capacity and 4 timesincethelast regeneration Thecomputer alwaysadjusts this pattern to your water using habits It works toward providing you with soft water for the longest time and the most efficient salt usage Softening capacity is used as hard water goes through the softener and hardness minerals are removed capacity is used When the computer determines that only enough capacity remainsto provide soft water up to the next regeneration starting time 2 00A M or as otherwiseset it will schedulearegeneration RECHARGE TONIGHT displays until the regeneration begins When the regeneration begins TONIGHT goes off and RECHARGE NOW flashes during the 2 hour regeneration SECTION 3 CARE OF YOUR SOFTENER 3A SALT REFILLING STORAGE TANK BREAKING A SALT BRIDGE WHEN TO REFILL WITH SALT The Salt Monitor System see page 10 will turn on the low saltlightto warn you when to refill with salt Check for a low salt light a few weeks after you install the softener and every week after that Always refill at about the 2 salt monitor level Atthislevel thetank is about 1 3full N ever let the softener use all the salt before refilling Without salt you will soon have hard water
9. number for each 1 ppm of iron In this example you would use25 for your hardness number 15 gpg hardness 2ppmironx5 10 10 times 25 HARDNESS NUMBER Press the JU P DOWN vbuttons to set your water hardness number in the display The DOWN button moves the display to 1 The UP button moves the display to the highest setting see maximum setting for your model in the specifications NOTE Each pressof theU P DOWN button changesthe display by 1 between 1 and 25 Between 25 and the highest number the display changes 5 at a time 25 30 35 etc Holding the UP or DOWN button in changes thedisplay twice each second 3 SET RECHARGE REGENERATION TIME Press the 1 SELECT button to display 2 00 AM flashing and RECHARGE TIME At the 2 00 AM RECHARGE TIME setting the softener be gins regeneration See pages 12 13 at 2 00 A M ending no later than 4 00AM Thisisa good timein most households because water is not being used see AUTOMATIC BY PASS page 14 If a different RECHARGE TIME setting would be better for your household do the following Press the AJUP DOWN v buttons to set the desired RECHARGE starting hour Be sure to observethe A M PM as you did when setting the present ti me of day NOTE Each press of the UP DOWN buttons changes the display 1 hour Holding the buttons in changes the display twice each second Press the 1 SELECT button once again to return the present tim
10. thesoftener s weightto rest on the inlet and outlet fittings or they will break 8 thebottom of thesoftener up afew inches and hold until all water has drained Leave the softener laying like this until you are ready to useit Plug the inlet and outlet with rags to keep dirt bugs etc out SECTION 3 CARE OF YOUR SOFTENER 3D HELPFUL HINTS CHECKLIST TO HELP YOU SAVE MONEY If your water softener failsto work makethefollowing easy checks Often you will find what s wrong yourself and you won t haveto call and wait for service If after making the checks your softener still does not work right call your Sears Service Department NOTE 1 Also read ERROR CODE page 11 2 If an error codeis not displayed press and hold the 1 SELECT button until example 000 shows in the display Then press the 1 SELECT again and hold until a flashing AR code appears It must show AR31 If AR 17 22 39 or 60 shows the face plate computer is working on incorrect input and would probably be the cause of the problem To set R31 press either the UP J or DOWN button When A R31 shows press the 1 SELECT to return aflashing 12 00AM display Reset the present ti me hardness number and recharge time pages 6 and 7 PROBLEM CAUSE CORRECTION NO SOFT WATER WATER HARD SOMETIMES No salt or salt bridged in the storage tank Refill with salt or break the salt bridge page 15 Press ON OFF HOLD RECHARGE N
11. until a shows opposite this number In the example below the light will come one when the stored salt dropsto level 2 Atlevel 2 thestorage tank is about 1 3full Thisisthelowest you should allow the stored salt level to drop to To turn the salt monitor off press the button until OFF shows indicator light N MONITOR O LOW SALT ALT LEVEL TANK LIGHT a black boxes NOTE For accurate salt monitor operation always use nugget or pellet water softener salt See page 9 SECTION 2 HOW YOUR WATER SOFTENER WORKS 2A FACE PLATE TIMER FEATURES TANK LIGHT To light the inside of the salt storage tank press the TAN K LIGHT button on the face plate Press the same button again to turn the light off or it will go off automatically in 4 minutes tank light ON indicator WATER FLOW RATE THROUGH THE SOFTENER To view the gallon per minute water flow rate through the softener if not already displayed press the 2 SELECT button If soft water is being used the flow rate to the closest 1 10 gallon shows If all faucets and water using appliances areoff thedisplay will show 0 flow AVERAGE DAILY GALLONS Press the 2 SELECT button again to show the average number of gallons of soft wa ter the household uses each day This water usagefigureis adjusted daily by the face plate timer To turn this dis play off press the 2 SELECT button once more PROGRAM MEMO
12. will weaken and shorten the life of some softener parts su 40 ou rae 03 a z a Brinewell Cover Brinewell Sodium information Water softeners using so dium chloride for regeneration add sodium to the water Persons who are on sodium restricted diets should consider the added sodium as part of their overall sodium intake For example if your water supply is 15 grains hard you would have to drink 3 quarts of softened water to consume 335 milligrams of sodium That is equivalent to eating 2 1 2 slices of white bread Persons who are concerned about their drinking water should consider a Sears Drinking Water System that will remove or reduce in excess of 9096 of the sodium and other drinking water contaminants You have now finished the water softener start up After the sanitizing recharge on page 8 the softener will be giving you soft water SECTION 2 HOW YOUR WATER SOFTENER WORKS 2A FACE PLATE TIMER FEATURES EXTRA RECHARGE Sometimes a manually started regeneration recharge may be desired or needed Two examples are You have used more water than usual guests visiting and you may run out of soft water before the next timer started regeneration You did not refill thesoftener with salt beforeit was gone You can start a regeneration right away or you can set thetimer toregenerate at the next 2 00 AM or other preset recharge time Do the following
13. 557 Siro lt DISTRIBUTOR pev BOTTOM DISTRIBUTOR During FAST RINSE the rotor amp disc is positioned so water flow enters the resin tank through the top distributor and exits through the bottom distributor to the drain The electronic timer again energizes the motor to return the valve to service Asthe valve rotates the position switch lever dropsto open the circuit The valve remains positioned in service until the electronic timer initiates the next regeneration 27 SECTION 6 REPAIR PARTS SEARS WATER SOFTENERS MODEL NOS 625 3485400 AND 625 3485500 KEY PART DESCRIPTION NO NUMBER 7137604 7137612 7118333 7084330 7144986 7137638 7137688 7141483 7139486 7137727 7143964 7100819 7144619 7143956 0900431 1103200 9003500 7123689 7105047 0502272 7144952 7096183 7077870 0900215 7079092 7141001 7088041 7088033 7084550 7137939 7137913 7141417 7137573 Rating Decal 28 not illustrated Included in parts bags see page 31 Aligns with top of brinwell Cover main Salt Hole Cover Wire Harness switch Power Cord transformer Timer Repl PWA Face Plate order req d decal Face Plate Decal Mod 625 3485400 Face Plate Decal Mod 625 3485500 Rim Brinewell Cover Wing Nut 1 4s Brinewell Salt Storage Tank Plastic Screw 1 4zx 5 8 Hose Clamp 6A Hose Adaptor 6A Grommet 6A Brine Valve Assy also see pg 29 R
14. AIR 1 800 473 7247 REPAIR SER For the location of a Sears Parts and Repair Center in your area Call 24 hours a day 7 days a week l 800 488 1222 For information on purchasing a Sears Maintenance Agreement or to inquire about an existing Agreement Call 9 am 5 pm Monday Saturday 1 800 827 6655 SEARS America s Repair Specialists Sears Roebuck and Co Hoffman Estates IL 60179 U S A 7137573 4 94
15. EP Fill in the blanks below and keep this book in a safe place so you always have these facts Water Softener Model No t Serial Number Date Installed Water Hardness Iron Content Grains Per Gallon Parts Per Million bH Taste And Or Odor Water Pressure Water Flow Rate Pounds S quare Inch Gallons P er Minute t The model number is on the rating decal located on the rim under the salt hole cover TABLE OF CONTENTS SECTION 1 SOFTENER START UP SAFETY GUIDES CHECK LIST OF STEP BY STEP GUIDES TO INSTALL PROGRAM THE TIMER SANITIZING THE WATER SOFTENER FILL THE STORAGE TANK WITH SALT moosr PAGE NO 1 OO SECTION 2 HOW YOUR WATER SOFTENER WORKS A FACE PLATE TIMER FEATURES B SOFT WATER SERVICE AND REGENERATION SECTION 3 CARE OF YOUR SOFTENER SALT REFILLING STORAGE TANK SALT BRIDGE KEEPING THE WATER SOFTENER CLEAN A B C KEEP THE SOFTENER FROM FREEZING D HELPFUL HINTS CHECKLIST SECTION 4 OTHER THINGS TO KNOW A DIMENSIONS SPECIFICATIONS SECTION 5 SERVICE TECH INFORMATION A TROUBLESHOOTING D ROTARY VALVE SERVICE E WATER FLOW THROUGH THE SOFTENER VALVE SECTION 6 REPAIR PARTS 10 11 12 14 15 16 17 18 19 20 23 25 27 28 31 SECTION 1 WATER SOFTENER START UP 1A SAFETY GUIDES A Read all steps guides and rules carefully be fore installing and using your new water softener Follow all steps exactly to correctly install Fail ur
16. ING IN THIS EXAMPLE water meter turbine count position switch indicator closed All of the preceeding displays show what position the valve is in if the turbine is operating and the position switch open or closed status 2 Press the ON OFF HOLD button to advance the valve to the next position To verify component operation or to possibly isolate a defect observe the following POSITION SWITCH STATUS With the valve in service or any of the recharge cycles the switch indicator will show open While the valve is rotating from 1 position to another the indicator will show the switch closed A defect is probable if indications vary from this pattern SECTION 5 SERVICE TECH INFORMATION 5 WATER METER TURBINE With soft water in use the turbine flow rate display continually repeats a 000 to 199 count for each gallon of water passing through the turbine The display will remain a steady2 000 if soft water is not in use open a nearby soft water faucet to check If you don t get a reading in the display with facuet open pull the sensor from the valve outlet port Pass a small magnet back and forth in frontof the sensor You should geta reading in the display If you get a reading unhook the in and out plumbing and check the turbine for binding MOTOR Bn RN S d SWITCH SENSOR HOUSING TURBINE TURBINE SUPPORT AND SHAFT VALVE POSITION INDICATORS Dep
17. OW button and hold for 3 seconds to start a regeneration see page 10 Transfomer unplugged at the wall outlet or power cable leads loose fuse blown circuit breaker popped or circuit switched off Check for loss of power due to any of these and correct With the power back on look at the time display and read PROGRAM MEMORY page 11 Manual bypass valve s in bypass position Look at FIG 12 on page 19 Move the stem in a single valve to service In a 3 valve bypass open the inlet and outlet valves and be sure to fully close the bypass valve Dirty plugged or damaged nozzle amp venturi Take apart and clean or replace damaged parts see page 16 Valve drain hose plugged Hardness number setting too low The drain hose must not have kinks sharp bends or be raised too high above the softener see page 16 in your installation manual Press and release the SELECT button until HARDNESS shows in the display Read the hardness number in the display and be sure the same grains per gallon number is shown on your water analysis report See page 7 to reset Press and release the SELECT button until the present time shows in the display Using hot water when softener is regenerating Avoid using hot water during this time because the water heater refills with hard water see Automatic Bypass page 14 Increase in the grains of hardness in your water supply 18 Ask your Sears retail or cata
18. R SOFTENER 3C KEEP THE SOFTENER FROM FREEZING If the softener is installed where it could freeze summer cabin lake home etc you must drain all water from it to stop possible freeze damage To drain the softener 1 Close the shut off valve on the house main water pipe near the water meter or pressure tank Open a faucet in the soft water pipes to vent pressure in the softener Refer to FIG 12 page 19 Movethestemin a single bypass valve to bypass Close the inlet and outlet valve in a 3 valve bypass system and open the bypass valve If you want water in the house pipes again reopen the shut off valve on the main water pipe Unplug the transformer at the wall outlet Remove the salt hole cover and the main cover Take off both drain hoses Carefully remove the large holding dips at the softener inlet and outlet see Key No 61 on page 30 Separate the softener from the adaptors or bypass valve Remove the brinewell cover and disconnect the brine valve tubing at the nozzle and venturi assembly see page 30 Lift the brine valveout of thebrinewell Tip the brinevalve upside down to drain out water 17 DRAIN WATER FROM THE SOFTENER 7 Looking at FIG 11 lay apieceof 2inch thick board near thefloor drain Movethesoftener close to the drain SLOWLY and CAREFUL LY tip it over until the rim rests on the wood block with theinlet and outlet over thedrain D onotallow
19. RY If electrical power to the softener goes off the time display is blank but the face plate timer keeps the correct time for about 72 hours When electrical power comes on again you have to reset the present time only if the display is flashing The HARDNESS and RECHARGE TIME never require resetting unless a change is desired Even if the timer is incorrect after a long power outage the softener works as it should to keep your water soft However regenerations may occur atthe wrong time of day until you resetthe timer to the correct time of day ERROR CODE Anerror codecould appear in the face plate display if a problem occursin thesoftener electronics If you see an error code instead of the present time of day please call you local Sears Service Depart ment for service SECTION 2 HOW YOUR WATER SOFTENER WORKS 2B SOFT WATER SERVICE AND REGENERATION SERVICE When the softener is giving you soft water itis called Service During service hard water comes from the house main water pipe into the softener Inside the softener resin tank is a bed madeup of thousands of tiny plastic resin beads FIG 4 As hard water passes through the bed each bead attracts and holds the hardness minerals This is called ion exchanging It is much like a magnet attracting and holding metals Water without the hardness minerals soft water flows out of the softener and into the house soft water pipes After a period of ti
20. SEARS OWNER S MANUAL MODEL NOS 625 3485400 Super Capacity Genius 625 3485500 Super Capacity Genius Caution Read and Follow All Safety Rules and Operating Instructions Before First Use of This P roduct If you have questions when installing operating or main taining your softener and when setting the timer call this toll free number 1 800 426 9345 SAVE THIS MANUAL Water Softeners Warranty Start Up Setting Timer How It Works Care Of Specifications Repair Parts Use plastic bag and tie provided to hang manuals nearby the softener for future reference Sears Roebuck and Co Hoffman Estates IL 60179 USA PRINTED IN U S A WARRANTY SEARS RESIDENTIAL WATER SOFTENER FULL TEN YEAR WARRANTY AGAINST LEAKS Forten years from the date of purchase Sears will furnish and installa new current model water softener tank or salt storage drum free of charge if either the tank or drum develop a leak FULL THREE YEAR ELECTRONICS WARRANTY Fora period of three years from date of purchase Sears will replace the BRINE TANK LIGHT ELECTRONIC BOARD SENSOR HOUSING WIRING HARNESS TRANSFORMER MICRO SWITCH DRIVE MOTOR OR POWER CABLE should they be defective in material or work manship FULL ONE YEAR WARRANTY ON WATER SOFTENER For one year from the date of purchase when this water softener is installed and maintained in accordanc
21. and Re venturi Lubricate the gear on the motor and the valve cam gear with Molykote grease or other high quality gear lubricant Be sure to orient switch as shown with lever toward the cam SECTION 5 SERVICE TECH INFORMATION 5C WATER FLOW THROUGH THE SOFTENER VALVE SERVICE CYCLE VALVE OUTLET Gi SOFT WATER 2 4 41 1 h RESIN RESINN BED BED DISTRIBUTOR Hard water enters the valve inlet port Internal valve porting routes the water down and out the top distributor into the resin tank Hard water is softened as it passes through the resin bed then enters the bottom distributor Soft water flows back into the valve and out the valve outlet to the house soft water pipes FILL CYCLE VALVE CAM POSITION ROTOR amp DISC SWITCH i fs VENTURI cef y af 9 VALVE INLET HARD WATER POSITION SWITCH VALVE OUTLET SOFT WATER To begin a regeneration the electroic timer energizes the circuit to the valve motor The valve motor rotates the rotor and disc and the valve cam until the position switch lever drops to open the motor circuit and position the valve in FILL As rotor and disc rotates the portopens for SOFT water fill through the venturi Fill flow continues to the brine valve and into the salt storage tank Soft water is still available to the house lines 2h SECTION 5
22. ardness step 2 the beeper sounds ON OFF HOLD indicator button display 1 SELECT button UP button DOWN button mchnat tom t CONTROL PANEL 2 SELECT button repeatedly when the display reaches 1 using the DOWN button or the highest hardness setting using the UP button 1 SET PRESENT TIME OF DAY NOTE If the words PRESENT TIME do not show in the display press the 1 SELECT button FIG 1 until they do or seethe notes above Press the JUP DOWN V buttons to set the present time Press UP to move the display ahead press DOWN to movetheti mebackward If the present time is between noon and midnight besurePM shows If the present time is between __ midnight and noon be sure AM shows NOTE Each press of the UP DOWN buttons changes the time by 1 minute H olding the buttonsin changes the time 32 minutes each second SECTION 1 WATER SOFTENER START UP 1C PROGRAM THE TIMER 2 SET WATER HARDNESS NUMBER Press the 1 SELECT button once to display 15 flashing and HARDNESS The grains per gallon gpg hardness of your water sup ply is on your water analysis report Be sure to enter water test results on page 2 for future reference NOTE If your water supply contains iron compensate for it by adding to the water hardness number For example assume your water is 15 gpg hard and contains 2 ppm iron dd 5 tothehardness
23. e and RECHARGE TO NIGHT in the display IF YOU NEED HELP PROGRAMMING THE TIMER CALL TOLL FREE NUMBER 1 800 426 9345 SEE PAGES 10AND 11 FOR OTHER FACE PLATE TIM ER FEATURES SECTION 1 WATER SOFTENER START UP 1D SANITIZING THE WATER SOFTENER Care is taken at the factory to keep your water softener clean and sanitary Materials used to make the softener will not infect or contaminate your water supply and will not cause bacteria to form or grow However during shipping stor age installing and operating bacteria could get into the softener For this reason sanitizing as follows is suggested when installing Lift the salt hole cover and use a pail or hose to fill the salt storage tank with at least 3 gallons of water 2 Remove the brinewell cover FIG 3 and pour about 3 4 ounce of common 5 2596 household bleach Clorox Linco BoPeep White Sail Eagle etc in the softener brine well 3 PresstheO N OFF H OLD button and hold for 3 seconds to start a recharge This first re charge does several things t draws the bleach into and through the softener to sanitize it Itfillsthesalttank tothewater level need ed t gets all the air out of the resin tank tmakestheresin bed see page 11 ready for service NOTES This recharge takes about 2 hours You can sanitize the softener with or with out salt in the storage tank Recommended by the Water Quality Association
24. e to follow them could cause personal injury or property damage Reading this book will also help you to get all of the benefits from your water softener A Your water softener will remove hardness min erals and clear water iron from water up to the limits shown on page 19 It will not remove other types of iron acids tastes and odors etc It will not purify polluted water or make it safe to drink A Protect the softener and piping from freezing Damage from freezing voids the softener warran ty See page 17 CAUTIONS PLEASE READAND PLY WITH THE FOL LOWING GUIDES TO PREVENT DAMAGE TO THE SOFTENER OR OTHER PROPERTY PERSONAL INJ URY OR POSSIBLE FATAL SHOCK A THIS SOFTENER WORKS ON 24 VOLTS ONLY BE SURE TO USE THE TRANSFORMER INCLUDED AND PLUG IT INTO A 120V OUT LET A Unplug the transformer right away if the power cable sould become damaged or frayed Make repairs before plugging back into the power outlet A Always unplug the softener from electrical power before removing outer valve covers SECTION 1 WATER SOFTENER START UP 1B CHECK LIST OF ALL STEP BY STEP GUIDES TO INSTALL Refer to the Installation Manual part no 7141417 for step by step guides To be sure you have done all the steps to install the softener read the following list Page num bers referred to the Installation M anual 4X4 Isthehouse water flow going INTO the soft ener valve INLET Trace piping to be s
25. e with our instructions Sears will repair free of charge all other parts which may be defective in material or workmanship TO OBTAIN WARRANTY SERVICE SIMPLY CONTACT THE NEAREST SEARS SERVICE CENTER THROUGHOUT THE UNITED STATES This warranty applies only while this product is in use in the United States This warranty gives you specific legal rights and you may have other rights which vary from State to state Sears Roebuck and Co D 817 WA Hoffman Estates IL 60179 If you want your water softener professionally installed talk to your Sears Salesman H ewill arrange for a prompt quality installation by Sears Authorized Installers SEARS INSTALLATION POLICY All installation labor arranged by Sears shall be performed in a neat workmanlike manner in accordance with generally accepted trade prac tices Further all installations shall comply with all local laws codes regulations and ordi nances Customer shall also be protected during installation by insurance relating to Property Damage Workman s Compensation and Public Liability SEARS INSTALLATION WARRANTY In addition to any warranty extended to you on the Sears merchandise involved which warran ty becomes effecti vethe datethe merchandisein installed should the workmanship of any Sears arranged installation prove faulty within one year Sears will upon notice from you cause such faults to becorrected at no additional costto you FACTS AND FIGURES TO KE
26. ending on the valve position the following indicators show in the display INDICATOR VALVE POSITION Serv service Fill fill Brine brining brine rinse Bkwash backwash Rinse fast rinse When the valve is rotating from 1 cycle to another both indicators flash For example if the valve is in transition between fill and brining both Fill and Brine flash Upon reaching brining position Fill goes off and Brine is on steady The time display shows the minutes of the cycle remaining NOTE If the face pla eft In a diagnostic flashing display when setting times or hardness present time automatically returns if a button is not pressed within 4 minutes To return to the diagnositc display repeat step 2 22 TROUBLESHOOTING OTHER INFORMATION While in this diagnostic screen the following information is available and may be beneficial for various reasons This information is retained by the computer from the first time electrical power is applied to the face plate Press display the number of days this face plate has had electrical power applied Press Ako display the number of regenerations initiated by this face plate since the AR code number was entered 3 Press the 1 SELECT button and hold 3 Sec AR31 shows This code identifies the softener nominal capacity size If the wrong number shows the softener will Operate on incorrect programming Do the following as needed AR31 does sh
27. eplacement Distributor Resin Resin Tank incl Key No 18 O Ring 2 3 4 3s Top Distributor O Ring 13 16 1 1 16 O Ring 2 7 8 lt 3 1 4 Vapor Barrier Clamp Section 2 req Clamp Retainer 2 req Transformer 24V 25VA A Light Salt Level Decal Salt Level Installation Manual Owners Manual SECTION 6 REPAIR PARTS SEARS WATER SOFTENERS MODEL NOS 625 3485400 AND 625 3485500 KEY PART DESCRIPTION NO NUMBER 0505957 Lead Washer 0513860 Float Stop 7092317 Float 0516947 Float Seal 7093216 FloatRod amp Stem 7092278 Guide Cap 0900535 O Ring 15 16 x 1 3 16 0516211 Seal 0516924 Retainer Bottom Seal 7116713 Clip 7092252 Brine Valve Body 7080653 Clip 7131365 Screen 7094979 Insert 7092294 Retaining Ring 7092286 O Ring 5 16 x 9 16 7095470 Brine Tube 7113016 Tubing Assy incl Key Nos 43 44 amp 45 7112997 Ground Clamp Kit 6A Included in parts bags see page 31 INLET OUTLET GROUNDING CLAMPS 29 SECTION 6 REPAIR PARTS SEARS WATER SOFTENERS ese VALVE ASSEMBLY 77 TUBING 30 SECTION 6 REPAIR PARTS SEARS WATER SOFTENERS MODEL NOS 625 3485400 AND 625 3485500 PARTS LIST KEY PART DESCRIPTION KEY PART DESCRIPTION no NUMBER 15 NUMBER 7131755 Screw 6 20 x 7 8 2 req 7113032 Nozzle and Venturi Gasket Kit 7133008 Motor incl
28. how fast the brine goes through the bed The nozzle and venturi FIG 6 make suction to take brine from the salt tank and put it into the resin tank They keep the brine flow down to a very slow rateto get the best resin cleaning with the least salt 3 BRINE RINSE After all of the brine goes into the resin tank the brine valve doses Water keeps flowing the same way it did during brining except the brine flow has stopped Hardness minerals and brine flush from the resin tank to the drain Brining and brine rinse together vary in the length of time they take relative to the fill cycle length WATER FLOW THROUGH THE SOFTENER IN BRINING AND BRINE RINSE Hard Water j Hard Water BYPASS Nozzle amp Venturi Brine Valve Brine BACKWA SH During backwash water flows UP through theresin tank FIG 7 at afast rateto flush iron minerals dirt and sediments from the bed and to the drain The bed lifts and expands for good cleaning 13 al Ce WATER FLOW THROUGH THE SOFTENER IN BACKWASH Hard Water IN Hard Water BYPASS ul resin bed and expa FAST RINSE Backwash is followed by a fast flow of water down through the resin tank The fastflow packstheresin bed and getsit ready for return to service FIG 8 After fast rinse the softener returns to service Hard water goes into the resin tank where the resin bed again takes out the hardness minerals Soft water goes to the house soft water
29. if needed 7081104 Nozzle amp Venturi Housing 1202600 Nut Ferrule 7144821 Parts Bag Model 625 3483500 incl parts marked with a A pages 7089267 Tubing 28 29 amp 31 order nice pa 1148800 Flow Plug 3 gpm rately if needed 2 PARTS INCLUDED WITH MODEL NO 625 3484400 ONLY 7129716 Seal Kit incl Key Nos 67 68 71 85 88 and 89 42 3433 Drain Hose 3 83l D x 204 not illustrated 1 PARTS INCLUDED WITH MODEL NO 625 3484500 ONLY BYPASS INSTALLATION VALVE MODEL NO 625 34372 KEY PART DESCRIPTION NO NUMBER 0502206 Retainer Ring 7129863 Bypass Body 7105013 O Ring 13 16 x 1 4 req 7130911 Stem 0900535 O Ring 15 16 x 1 3 16 2 req 42 3437 Bypass Valve Complete OWNER S MANUAL MODEL NOS 625 3483400 625 3483500 The model number of your water softener is found on the rating de cal This decal is on the rim under the salt cover When requesting service or ordering parts always provide the following in formation Product Type Model Number Part Number Part Description Kenmore Demand Water Softeners For the repair or replacement parts you need delivered directly to your home Call 7 am 7 pm 7 days a week 1 800 366 PART 1 800 366 7278 For in home major brand repair service Call 24 hours a day 7 days a week 1 800 4 REP
30. log store for a new water analysis Then make a new hardness number setting page 7 SECTION 4 sy Pass VALVES SINGLE PLASTIC SINGLE BRASS PULL STEM OUTWARD FOR SERVICE 3 VALVE SERVICE Close Bypass Valve Open Iniet amp Outlet Valves BYPASS Open Bypass Valve Close Inlet amp Outlet Valves OTHER THINGS TO KNOW DIMENSIONS SPECIFICATIONS INCHES CM Salt Tank Height 40 1 4 102 2 Tank Diameter nominal 9 22 7 C Tank Height nominal 40 101 6 D Inlet Outlet Height 41 1 2 105 4 E Overall Height 46 116 8 Length 19 1 2 49 5 F2 Width 16 1 2 41 9 Distance between inlet outlet 3 3 8 8 6 center lines MODEL NO 625 3485400 AND 625 3485500 TIMER AR CODE AR31 NOTE Please see the rating decal for water softener operating capacity salt usage and service flow rate pressure loss performance specifications Performance specifications are validated by the Water Quality Association WQA Therating decal is located on the rim under thesalt hole cover see page 28 WATER SUPPLY TO WATER SOFTENER MINIMUM WATER SYSTEM FLOW gpm 3 MINIMUM MAXIMUM WATER PRESSURE psi 20 120 MAXIMUM WATER TEMPERATURE 120 MAXIMUM WATER HARDNESS gpg 110 MAXMUM CLEAR WATER IRON ppm 8 SALT FOR WATER SOFTENER TYPE OF SALT NEEDED ALTERNATE TYPE OF SALT Nugget P ellet Pure eva
31. mbing bypass valve s must be in Full Service position Theinlet and outlet pipes must connect to the softener inlet and outlet respectively 15 transformer plugged into a live grounded wall outlet and the power cable fastened securely The valve drain hose must be free of kinks and sharp bends and not elevated over 8 ft above the floor 20 hardness setting Be sure it is the correct setting for the household s water supply Make a hardness test of the raw water and compare with the hardness setting Also test a soft water sample to verify if a problem exists Press the 1 SELECT button twice more to return to present time in the display If you do not find the problem after making initial checks do the MANUAL INITIATED ELECTRONIC DIAGNOSTICS and the MANUAL ADVANCE REGENERATION CHECK SECTION 5 SERVICE TECH INFORMATION 5 AUTOMATIC ELECTRONIC DIAGNOSTICS The face plate computer has a self diagnostic function for the electrical system except input power and water meter The computer monitors the elec tronic components and circuits for correct operation malfunction occurs an error code appears in the face plate If a TROUBLESHOOTING The chart below shows the error codes that could appear and the possible defects for each code While an error code appears in the display all face plate buttons are inoperable except the SELECT button SELECT remains operational so the se
32. me the resin beads become coated with hardness minerals and they haveto be cleaned This cleaning is called regeneration or recharge Regeneration is started at 2 00 a m by the electronic timer see page 14 It takes placein 5 stages or cydes These are FILL 4 BACKWASH BRINING 5 FAST RINSE BRINE RINSE WATER FLOW THROUGH THE SOFTENER IN SERVICE Hard Water IN ud Al Resin Tank Resin Bed Salt Storage Tank 12 REGENERATION FILL Salt dissolved in water is called brine Brine is needed to dean the hardness mineralsfromtheresin beads To makethebrine water flows into the salt storage area during the fill stage as shown in FIG 5 Fill cycle length depends on how much soft water making capacity you have used since the last regenera tion Asyou usemore water fill ti meincreases so more brineis made The greater amount of brine deans more hardness minerals from the resin bed WATER FLOW THROUGH THE SOFTENER IN FILL Hard Water nd Tl i Salt Storage Tank salt not shown Fil Water SECTION 2 HOW YOUR WATER SOFTENER WORKS 2B SOFT WATER SERVICE AND REGENERATION 2 BRININ G During brining thebrineismoved from the salt storage area into the resin tank Inside the resin tank brine cleans hardness minerals from the resin beads and they are discharged out the drain How much brine is needed to clean the resin depends on the amount of resin in the softener
33. nto backwash Look for a fast flow of water from the drain hose An obstructed flow indicates a plugged top distributor backwash flow plug or drain hose Press ON OFF HOLD to move the softener into fast rinse Again look for a fast drain flow Allow the softener to rinse for afew minutes to flush out any brine that may remain in the resin tank from the brining cycle test To return the softener to service press ON OFF HOLD BRINE VALVE Float Stop FREEBOARD MEASUREMENT Distance from top of resin tank to top of resin bed Resin Tank FREEBOARD TUM SECTION 5 SERVICE TECH INFORMATION 5B Before working on the valve turn off the water supply and disconnect from electrical power TO RELIEVE PRESSURE 3 VALVE BY PASS Close the inlet valve and open a soft water faucet Then close the outlet valve and open the bypass valve SEARS SPECIAL BY PASS Slide the bypass valve stem to bypass position Loosen the 3 hex head screws see A in drawing toward the back side of the valve to allow pressure water to bleed out Catch water with a rag DISASSEMBLY To remove a part or group of parts refer to the valve drawing A common screwdriver or nut driver Phillips screwdriver and pliers are the only tools needed to completely disassemble SERVICING THE VALVE Inspect all o rings seals and gaskets for wear or defects Inspect the bottom surface of the rotor and disc for scratches
34. ool into salt bridge to break Broom Handle Salt Salt Bridge Water Level SECTION 3 CARE OF YOUR SOFTENER 3B KEEPING THE WATER SOFTENER CLEAN COVERS To keep your new Sears water softener looking nice apply acoat of paste wax and repeat oncea year When dusty wipe it with a damp cloth to keep it sparkling NOZZLE amp VENTURI A clean nozzleand venturi FIG 10 isamustfor thesoftener to work right Thissmall unit moves brine from the salt storage tank to the resin tank during regeneration If it becomes plugged with sand silt dirt etc the softener will not work and you will get hard water To get to the nozzle and venturi remove the softener top cover Be sure the softener is in service cycle no water pressure at nozzle and venturi then turn off the cap from the nozzle and venturi housing Do not lose the large o ring seal Lift out the screen support and screen then the nozzle venturi Wash and rinse the parts in warm water until clean If needed useasmall brush to remove iron or dirt Also check and clean the gasket Carefully replace all parts in the correct order Lubricatetheo ring seal with silicone greaseor Vaseline and place in position Install and tighten thecap by hand only D o notovertigh ten and break the cap or housing IRON FROM THE RESIN BED Your water softener takes hardness minerals calcium and magnesium out of the water Also it can control some
35. ow Press the 1 SELECT button to return the present time display To change AR number press the Abr Mutton until AR31 shows The press the 1 SELECT button and reset the timer page 6 FACE PLATE REPLACEMENT BE SURE THE VALVE IS IN SERVICE POSITION OB SERVE VALVE CYCLE INDICATOR WHEN REPLACING THE FACE PLATE If after installing and programming the re ue SES placement face place the valve is not in ser VO vice position do the fol lowing to assure correct cycle orientation or tim ing between the face plate and valve Use the MANUAL ADVANCE procedures page 23 With the RECHARGE NOW button advance through the recharge cycles until the valve stops in service position and RE CHARGE no longer flashes in the timer NOTE The valve motor may automatically drive through several valve positions while searching for service If an error code occurs unplug the transformer then plug in again Valve Position uae Indicator Cam SECTION 5 SERVICE TECH INFORMATION 5 MANUAL ADVANCE REGENERATION CHECK This check verifies proper operation of the valve motor brine tank fill brine draw regeneration flow rates and other controller functions Always make the initial checks and the manual initiated diagnostics NOTES The face plate display must show a steady time not flashing If an Error code shows first press the 1 SELECT button to enter the diagnostic display 1 Press
36. pipes WATER FLOW THROUGH THE SOFTENER IN FAST RINSE Hard Water Soft Water IN OUT Drain SECTION 2 HOW YOUR WATER SOFTENER WORKS 2B SOFT WATER SERVICE AND REGENERATION AUTOMATIC BYPASS During the brining brine rinse and backwash cycles of regeneration HARD water goes through the softener valve and to the house pipes If a faucet is opened hard water is there for your needs However you should not use water if possible because the water heater will refill with hard water The softener regener ates from 2 00 to about 4 00A M you can set anytime a time when not much water is used If you get up early in the morning and you can hear the softener regenerating change the time setting Set the recharge 12 00AM or 1 00 AM page 7 Then regeneration will start and end that much earlier and your water heater will not refill with hard water if a hot faucet is opened Two main parts of the softener s electronics are 1 a WATER METER and 2 a COMPUTER WATER METER The water meter is in the softener val veoutlet As water flowsthrough the meter it sends electric pulses to the computer Thecomputer changesthe pulsesto a measurein gallons of water 14 2 COMPUTER The computer is part of the circuit board It is programmed to know the softener s capacity how many grains of hard ness mineralsit will takeout of thewater beforea regeneration
37. porated compacted water softener salt STORAGE CAPACITY pounds 200 19 OTHERS TYPE OF ION EXCHANGE MATERIAL resin High Capacity AMOUNT OF RESIN cu ft 1 0 REGENERATION RECHARGE CYCLE TIME min FILL 2 7 10 3 BRINING BRINE RINSE 97 106 BACKWASH 7 FAST RINSE 3 TOTAL REGENERATION TIME 109 7 126 3 gpm gallons per minute gpg grains per gallon psi pounds per square inch ppm parts per million SECTION 5 SERVICE TECH INFORMATION TROUBLESHOOTING Keep this manual with your water softener If repairs are needed the service technician must have the information on the following 8 pages For telephone assistance call toll free 1 800 426 9345 WIRING SCHEMATIC CIRCUIT BOARD TRANSFORMER 24VAC 110 VAC POSITION SWITCH grn NO ALWAYS MAKE THESE INITIAL CHECKS FIRST REMOVE THE TOP COVER AND SALT TANK COVER 1 Does the time display show the correct time of day 6 15 there salt the storage tank If display is blank check power source to the soft 7 15 the brine tubing connected See water flow ener diagrams ftimeisflashing power was off for over 24 hours The softener resumes normal operation but regenerations 8 15 the brine valve float set right See page 23 occur at the wrong time an error code Example Err3 shows the face plate e Press the 1 SELECT button 2 times to display the display go to AUTOMATIC ELECTRONIC DIAGNOS TICS Plu
38. rvice person can make the MANUAL INITIATED ELECTRONIC DIAGNOSTICS below to further isolate the defect and check the water meter display POSSIBLE DEFECT CODE MOST LIKELY e e LESS LIKELY Errl motor inop wiring harness or connection to switch position switch face plate Err2 face plate Err3 motor face plate See face plate replacement on Err4 face plate position switch page 22 Err5 face plate PROCEDURE FOR REMOVING ERROR CODE FROMFACE PLATE 1 Unplug transformer 2 Correct defect 3 Plug in transformer 4 Wait for 6 minutes The error code will return if the defect was not corrected MANUAL INITIATED ELECTRONICS DIAG NOSTICS 1 To enter diagnostics from a error code display press the 1 SELECT button from a time display press and hold the 1 SELECT button for 3 seconds You will see 1 of the following displays valve position indicator number of days since the last regeneration VALVE IN SERVICE POSITION water meter turbine count position switch indicator open valve position indicator minutes of fill cycle remaining VALVE INA RECHARGE POSITION FILL IN THIS water meter EXAMPLE turbine count position switch indicator 21 valve position indicator Fill and Brine flashing minutes of brining time begins to count down VALVE ROTATING brini ition di FROM 1 RECHARGE POSITION TO ANOTHER FROM FILL TO BRIN
39. the ON OFF HOLD button and hold in for 3 seconds RECHARGE NOW and FILL begin to flash as the softener enters the fill cycle of regeneration When FILL is on steady remove the brinewell cover and using a flashlight observe fill water entering the tank If water does not enter the tank look for an obstructed nozzle venturi fill flow plug brine tubing or brine valve riser pipe CYCLE FLOW RATES GALLONS PER MIN FILL flow to salt storage tank 0 3 1 1 liters BRINING 19 7 liters BRINE RINSE 12 45 liters BACKWASH flow to drain 2 0 7 6 liters FAST RINSE 2 0 7 6 liters 2 After observing fill press the ON OFF HOLD button to move the softener into brining A slow flow of water to the drain will begin Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level NOTE Be sure a Salt bridge is not preventing water with salt contact the softener does draw brine 2 nozzle and or venturi dirty or defective nozzle and venturi not seated properly on gasket restricted drain check drain fitting and hose defective nozzle and venturi seal other inner valve defect rotor seal rotor amp disc wave washer etc a IO IO IO IO 23 TROUBLESHOOTING NOTE If water system pressure is low an elevated drain hose may cause back pressure stopping brine draw 3 Again press ON OFF HOLD to move the softener i
40. ure See pages 10 and 11 4 Istheplumbing bypass valve or 3 valves set for SERVICE See FIG 12 page 19 of this manual 4 15 the valve drain hose connected the right way and without sharp bends or kinks that could stop or reducewater flow See page 16 15 softener power cable connected to the transformer Is thetransformer plugged into an inside 120V 60Hz electrical outlet See page 20 X Besureto restart the water heater See page VALVE INLET Q SECTION 1 WATER SOFTENER START UP 1C PROGRAM THE TIMER SALT LEVEL ADJ button low salt SIGNAL LIGHT __ ADJ button TANK LIGHT on off button When the transformer is plugged in the model code AR31 and a test number example A 1 0 show in the face plate display for 4 seconds Then 12 00 AM and PRESENT TIME begin to flash NOTE If AR shows in the display press the UP Jor DOWN vbutton until AR31 shows Then press the 1 SELECT button to set and change to the flashing PRESENT TIME display check themodel code unplug thetransformer at the wall outlet and plugin again if other than AR31 shows see page 18 to reset SOUND BEEPER A beeper sounds while pressing buttons for timer set up One beep signals a change in the face plate display Repeated beeps mean thetimer will not accept a changefromthe button you have pressed telling you to use another button For example while setting the h
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung AE 3TL 40-46 平成23年7月号一括(PDF文書) Libretto Istruzioni Vivanco Laptop screen cleaning fluid Scarica manuale RE.COR.D M-Cab HDMI, 30 m Toshiba Satellite P850/099 サンプル(PDFダウンロード) StarTech.com 2m Multimode 50/125 Duplex Fiber Patch Cable LC - LC MANUAL TECNICO - Repositorio CISC Copyright © All rights reserved.