1. SERVICE INSTRUCTIONS __wankeatngotencago com KEATING oenn 7 OF CHICAGO INC DELAYED IGNITION OR FAILED RECTIFICATION INCREDIBLE FRYING MACHINE All installation and service on Keating equipment must be performed by qualified certified licensed and or authorized installation or service personnel m Check gas pressure at the manifold with the fryer operating and all gas equipment in the kitchen turned on and operating Natural gas 7 line 3 water column at the manifold LP gas 11 line 10 water column at the manifold m Check both gaps on spark electrode by removing the burner Pilot tube and electrode 0 125 1 8 Pilot tube and burner 0 125 1 8 SPARK GAP 0 125 TEAR DROP PILOT GROUND ROD TUBING TO BURNER SPACING PROCEDURE 1 Remove the entire burner assembly Only disconnect the spark leads from the spark module Leave the other end connected to the spark electrode Adjust the gap between the electrode and burner 0 125 Adjust the spark between the pilot tube and electrode 0 125 Remount the burner assembly Dr yee ey Th Reconnect the high voltage lead to the spark module 7 05 DlydigntniIFM