1. SERVICE INSTRUCTIONS KEATING OF CHICAGO INC www keatingofchicago com REPLACEMENT MOUNTING AND WIRING INSTRUCTIONS KEATING ELECTRONIC TIMER HEX NUT 7 MOUNTING CLIP aS REPLACEMENT TIMER MOUNTING Remove old timer and mount new Keating digital timer as shown NOTE When removing the wires from the old timer mark the terminal number for reference when re wiring FRONT OF CONTROL PANEL IOP VIEW FRONT REPLACEMENT TIMER WIRING Wire the new Keating digital timer using the old timer to new timer terminal reference shown NOTE On fryers that use the output terminals e g IFM s or units with basket lift use the wire extension that is included with the kit on COM terminal or power input terminal where necessary OUTPUT RELAY COM amp NO POWER ie SAME AS neur SAME AS TERMINAL TERMINAL 5 6 SAME AS TERMINAL 2 OUTPUT RELAY SAME AS TERMINAL 3 SEE NOTE OLD TIMER BELOW NEW TIMER 011193 023709 1 800 KEATING 4 2 TmrRpicmntWireM ount