1. es sorties de contr le Pour les d tails veuillez vous repor ter au mode d emploi de l amplifica baut wird teur auquel le RCM 810 est associ Part Number RCM 810 Remote Control Module D 170 446 Inhalt Contents Contenu 1 x Technische Informationen RCM 810 1 x RCM 810 2 x Stecker 3 pol Phoenix MC1 5 3 STF 3 81 Nr 1827716 1 x Verbindungskabel 34 polig 60 mm 2 x Schrauben Kombi Torx M3x10 GEN A o 1 x Engineering Data Sheet RCM 810 1 x RCM 810 2 x Connector 3 pole Phoenix MC 1 5 3 STF 3 81 Nr 1827716 1 x Ribbon Cable 34 pole 60 mm 2 x M3x10 Combination Torx Screws Printed in Germany Vs 02 1 x Informations techniques RCM 810 1 x RCM 810 2 x Connecteurs 3 pdles Phoenix MC 1 5 3 STF 3 81 Nr 1827716 1 x Cordon d interconnexion interne 34 pdles 60 mm 2 x Vis Combination Torx M3x10 GmbH Hirschberger Ring 45 94315 Straubing Telefon 09421 706 0 Telefax 09421 706 265 Subject to change without prior notice 10 03 2009 D367600 FO1U108146 Aler RCM 810 Block Diagram Only 2 Channel AMP 45v e Sa SRAM U TEMP _
2. les 2 vis voir illustration ci dessous Remettez en place le fond de I amplifi cateur le cordon d interconnexion ne doit pas tre cras R glez l adresse CAN du module a l aide des switches du s lecteur ADDRESS Connectez les interfaces ad quates CAN Port de Contr le Rebranchez le cordon secteur et met tez sous tension l amplificateur de puissance le module RCM 810 est automatiquement reconnu par l ampli ficateur RCM 810 Printed in Germany Vs 02 GmbH Hirschberger Ring 45 94315 Straubing Telefon 09421 706 0 Telefax 09421 706 265 Subject to change without prior notice 10 03 2009 D367600 F01U108146 Aler CAUTION These installation instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the owners manual unless you are qualified to do so Montage in 2 Kanal Endstufe 1 Endstufe ausschalten und Netzstek 1 ker abziehen 2 Entfernen Sie die 4 Schrauben des 2 Endstufen Deckels 3 L sen Sie den Deckel wie abgebildet 3 und ziehen Sie ihn nach vorne weg 4 Leerblende an R ckwand der End 4 stufe abschrauben 2 Schrauben 5 RCM 810 Modul in Slot einschieben 5 und mit 2 Schrauben an R ckwand befestigen 6 Kabelverbindung mit 34 poligem 6 Flachbandkabel
3. Aler RCM 810 REMOTE CAN ADDRESS CAN BUS IN 1 2 4 HESE CONTROL PORT Beschreibung Das Remote Control Modul RCM 810 ist ein optionales Einbaumodul zur Uberwachung und Fernbedie nung einer Endstufe Uber ein Re mote Control Netzwerk An einem Remote Netzwerk k n nen maximal 100 Endstufen ange schlossen sein IRIS Net kann mehrere Remote Control Netz werke mit bis zu 250 Geraten ver walten Neben der Netzwerk Schnittstelle stellt das RCM 810 zwei Steuereing nge und zwei Steuerausg nge zur Verf gung Weitere RCM 810 Eigenschaften e Steuerung Konfiguration Power ON OFF Einschaltverzogerung Mute Steuerein und ausgange e Uberwachung Anzeigen Angeschlossene Last f r jeden Endstufen Kanal Output VU Protect Limit Pilotton Temperatur Gain Sensitivity Steuerein und ausgange Alle Details hierzu finden Sie in den Bedienungsanleitungen der End stufen in die das RCM 810 einge Description The RCM 810 Remote Control Module is an optional module for supervision and remote control of power amplifiers RCM 810 modules allow the ampli fiers to be integrated into a remote control network with up to 100 devices Up to 250 amplifiers can be used in an IRIS Net project when multiple networks are used Apart from the network port the RCM 810 also offers freely pro grammable control inputs and con trol outputs Additional RCM 810 features e Con
4. e 2 vis Ins rez le module RCM 810 dans le slot et verrouillez le en place sur le panneau arri re a l aide des 2 vis voir illustration ci dessous Faites les branchements suivants a l aide du cordon d interconnexion de 60 mm CN4 du module RCM 810 reli a CN3 de la carte m re de l amplificateur Remettez en place le dessus de amplifi cateur R glez l adresse CAN du module a l aide des switches du s lecteur ADDRESS Connectez les interfaces ad quates CAN Port de Contr le Rebranchez le cordon secteur et mettez sous tension l amplificateur de puissance le module RCM 810 est automatiquement reconnu par l amplificateur RCM 810 smc olele 37 ANI 100 5 LJe Om n GN A o Subject to change without prior notice d i GmbH Hirschberger Ring Ap 94315 Straubing Telefon 09421 706 0 Telefax 09421 706 265 Printed in Germany Vs 02 10 03 2009 D367600 F01U108146
5. gt bea RE et Wola REMOTE le CAN BUS Sis CURRENT A B LC D Laich DEE K A CURRENT AIB DC J CAN LED ne 5V oe aa CH Ss lt 1 le REDUCTION ADDRESS gt A 4 amp gt P S e apc he s INIT 7 Rm gt i Detection 5V p PEA Controller BRIDGED gt MEAE lt q 5V CONTROL 14 Li PORT AGND EE gt Technical Specifications NETWORK AND GENERAL FEATURES Remote Control and Software IRIS Net Multiple PCs possible MS Windows 2000 XP Vista Maximum Configuration 250 Amplifiers in total 100 Amplifiers per CAN bus 1000 meter cable run Amplifier Supervision Operation mode temperature output voltage and current impedance of connected speakers protection mode status pilot tone detection Network Supervision CAN bus failures defective or missing amplifiers bandwidth failure protocol and messaging INTERFACES CAN 10 500 kbaud 2 x RJ 45 IRIS Net Control GPIO Control Port 2 x 3 pole Euro block 2 Control Inputs 2 Control Outputs 2 Reference Outputs 5 V 200 mA GND RCM 810 GENERAL SPECIFICATIONS Supply Voltage Current 5 V DC 320 mA 15 V DC 80 mA 15 V DC 80 mA Power Consumption AW Operating Temperatur Range 0 C 40 C Dimensions W x H x D 103 5 x 37 x 103 mm Weight 115g ACCESSORIES 3 pole Euro block connector For GPIO Control Port J GmbH Hirschberger Ring Ap 94315 Straubing Telefon 09421 706 0 Telefax 09421 706 265 e AUDIO Subject to change wit
6. herstellen CN4 auf RCM 810 Modul mit CN3 auf Endstu fenboard 7 Endstufen Deckel aufschrauben Te 8 CAN Adresse am Modul ber 8 ADDRESS Schalter einstellen 9 AnschlieRen ben tigter Schnittstellen 9 CAN Control Port Netzkabel in Endstufe einstecken und Endstufe einschalten das Modul wird automatisch erkannt 10 10 Abmessungen Dimensions 103 5 Installation 2 channel amp Switch off the power to the amplifier and remove the mains lead Remove the 4 screws from the top cover of the amplifier Loosen the top cover as shown and remove it by pulling it out towards the front panel Remove the cover panel from the rear panel 2 screws Slide the RCM 810 module into the slot and secure in in place using the 2 screws see illustration below Gently push the 60 mm ribbon cable into the connector labelled CN4 on the RCM 810 and the connector labelled CN3 on the amplifier main board Refit the top cover Set the module s CAN address using the ADDRESS selector switches Connect the interfaces required CAN Control Port Reconnect the mains lead and switch the amplifier on the RCM 810 is auto matically detected and is now ready for use Installation ampli a 2 voies 1 2 103 Eteignez l ampli de puissance et d bran chez le du secteur Retirer les 4 vis du capot sup rieur de ampli Retirer le capot comme indiqu en le tirant vers soi Enlevez le panneau arri r
7. hout prior notice Printed in Germany Vs02 10 03 2009 D367600 FO1U108146 Aler CAUTION These installation instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the owners manual unless you are qualified to do so Montage in Mehrkanal Endstufe 1 10 11 12 GEN A o Endstufe ausschalten und Netzstek ker abziehen Entfernen Sie die 4 Schrauben des Endstufen Bodens L sen Sie den Boden wie abgebildet und ziehen Sie ihn nach vorne weg Leerblende an R ckwand der End stufe abschrauben 2 Schrauben Fixierung des 16 poligen Flachband kabels durch Kabelbinder l sen siehe Abbildung RCM 810 Modul in Slot einschieben Kabelverbindung mit RCM 810 her stellen 16 poliges Flachbandkabel in CN3 auf RCM 810 Modul einstecken Modul unter Verwendung der seitli chen F hrung horizontal ausrichten siehe Abbildung und mit 2 Schrau ben an R ckwand befestigen Endstufen Boden aufschrauben das Flachbandkabel darf nicht besch digt eingeklemmt werden CAN Adresse des Moduls ber ADDRESS Wahlschalter einstellen Anschlie en ben tigter Schnittstellen CAN Control Port Netzkabel in Endstufe einste cken und Endstufe einschalten das Modul wird automatisch erkannt Installation multi channel amp 1 10 11 12 Switch off the power to the amplifier and disconnect the mains lead Remove the 4 scre
8. trol Configuration Power ON OFF Power On Delay Mute Control Inputs Outputs e Supervision Status indicators Load supervision for each ampli fier channel Output VU Protect Limit Pilot tone Temperature Gain Sensitivity Control Inputs Outputs For further details please check the owner s manual of the amplifier which the RCM 810 will be used in Technische Informationen Engineering Data Sheet Informations Techniques RCM 810 Remote Control Module Description Le module de t l commande RCM 810 est un module optionnel pour la surveillance et la commande a dis tance d amplificateurs de puissance Les modules RCM 810 permettent d int grer les amplis dans un r seau contr l a distance comprenant un maximum de 100 membres En utili sant des r seaux multiples a l int rieur d un projet IRIS Net il est possible d utiliser un maximum de 250 amplis En plus de son port r seau le RCM 810 propose gale ment des entr es et des sorties de contr le enti rement programma bles Autres caract ristique du RCM 810 e Contr le Configuration Interrupteur Marche Arr t Temporisation la mise sous ten sion Mute Entr es sorties de contr le e T moin de Surveillance et d tat Surveillance de la charge de cha que canal de l ampli VU m tre du niveau de sortie T moin Protect T moin Limit Tonalit Pilote Temp rature Gain Sensibilit Entr
9. ws from the bot tom cover of the amplifier Loosen the bottom cover as shown and remove it by pulling it out towards the front panel Remove the cover panel from the rear panel 2 screws Release the 16 pole ribbon cable by cutting the tie wrap see illustration below Insert the RCM 810 module into the slot Plug the 16 pole ribbon cable into the connector labelled CN3 on the RCM 810 module Slide the module into place locating it into the guide slot on side of the chassis and secure it in place using the 2 screws Refit the bottom cover making sure the ribbon cable will not be damaged Set the module s CAN address using the ADDRESS selector switches Connect the interfaces required CAN Control Port Reconnect the mains lead and switch the amplifier on the RCM 810 is auto matically detected and is now ready for use Installation multi channel amp 1 2 10 11 12 Eteignez l ampli de puissance et d branchez le du secteur Retirer les 4 vis de la plaque situ e a l arri re de l ampli Retirer la plaque comme indiqu en la tirant vers soi Enlevez le panneau arri re 2 vis D tachez le cable 16 points en cou pant le lien voir illustration ci des sous Ins rez le module RCM 810 dans l emplacement Branchez le c ble 16 points en CN3 sur le module RCM 810 Ins rez le module horizontalement en utilisant le guide situ sur le c t du chassis et bloquez le en utilisant