1. utoScan Mode Specification PC Connections Direct PC Selection PC with plugs at the 1x USB Type A end of the cables 2 x HDB 15 M Blue Connector 1 x Mini DIN 6 F Green 1 x HDB 15 F Blu Specification Con d aeo Keybearfouse Emulation CEN Meme iw Mum ww emm Dimensions LxWxH 2 5 x 2 25 x 0 875 with 6 cables Resolution Enclosure Troubleshooting Possible Cause Action Symptom Check all keyboard cable connections to make sure they are completely seated in the sockets Loose cables Keyboard needs to be Unplug the keyboard from the Console Keyboard Port then plug it Keyboard Not reset back in Responding MiniView Micro Turn off computers Unplug the cables from the unit Wait five needs to be reset seconds then plug the cables back in and tum the computers on RAPERE HER EE Miiview Miro iei Press the Spacebar to exit AutoScan mode AutoScan mode Fosse nds Resend the Hot Key command selecting a port that has a red off computer powered on computer attached ieu ed A Hot Key sequence Resend the Hot Key command press and release each key in po input incorrectly the sequence individually Micro isin Press the Spacebar to exit AutoScan mode Troubleshooting Con d Symptom Possible Cause Action Check all mouse cable co
2. IOGEAR Table of Contents lt 02 x hat ee Bo Rw UR 03 Features ss ek See TT 04 Requirements Sr a a ae Sa eh Sw 05 Introduction so RR Roos 06 Installation s oos 07 Operation Jw dad op m de dE om UP Rl 10 Appendix Hotkey 13 Specification lt s s so s s moa ww cea Coro e 14 Troubleshooting o 2 16 Tech Support VI 18 Radio amp TV Interference Statement sse 19 Limited Warranty o t t ne 20 Package Contents This package contains 1 MiniView Micro USB 2 port KVM switch 1 User Manual 1 Quick Start Guide 1 Warranty Registration Card If any items are damaged or missing please contact your dealer The MiniView Micro USB GCS52U KVM switch allows access to two USB computers from a single console keyboard monitor and mouse This cost effective way to access two computers without extra hardware is highly efficient and easy to use By allowing a single console to manage both computers the MiniView Micro eliminates the expense of purchasing extra keyboards monitors mice and the MiniView Micro eliminates the extra space they would take up The MiniView Micro USB KVM is small portable and fits right on or under your desktop It also comes with a built in KVM cabl
3. Miniview see Micro USB 2 Port KVM Switch with Built in KVM Cables Installation Manual GCS52U 2003 IOGEAR All Rights Reserved PKG M0073 IOGEAR the IOGEAR logo MiniView VSE are trademarks or registered trademarks of IOGEAR Inc Microsoft and Windows are registered trademarks of Microsoft Corporation IBM is a registered trademark of International Business Machines Inc Macintosh G3 G4 and iMac are registered trademarks of Apple Computer Inc IOGEAR makes no warranty of any kind with regards to the information presented in this document All information furnished here is for informational purposes only and is subject to change without notice IOGEAR Inc assumes no responsibility for any inaccuracies or errors that may appear in this document Thank you for purchasing one of the most feature rich keyboard video and mouse switches on the market IOGEAR s MiniView Micro switches are first rate connectivity accessories designed to help reduce the frustration of managing multiple computer systems With the MiniView Micro by IOGEAR you can access two computers from a single console keyboard mouse and monitor MiniView Micro allows you to change ports easily by entering Hot Key combinations from the keyboard Setup is fast and easy plugging cables into their appropriate ports is all that is entailed We hope you enjoy using your MiniView Micro USB KVM yet another first rate connectivity solution from
4. S 2 port for the console mouse 4 VGA connector to the computer 5 USB connector to the computer 6 Port selected LEDs Installation Step 1 Before you begin please turn off the computers you are going to connect to the MiniView Micro USB KVM If you have never installed a USB mouse and Keyboard on your computer before you may need to leave your PS 2 mouse and keyboard attached during the first boot up after installing the GCS52U After you have installed the KVM shutdown your computer and move the PS 2 mouse and keyboard to the GCS52U console port You have now installed the unit 1 Connect your monitor VGA cable to the female VGA port item 1 on your MiniView Micro 2 Connect your PS 2 keyboard directly into the PS 2 keyboard port item 2 on your MiniView Micro 3 Connect your PS 2 mouse directly into the PS 2 mouse port item 3 on your MiniView Micro Installation Step 2 4 Connect the VGA cable item 4 that is built into the KVM cable of your MiniView Micro to the VGA port on your computer 5 Connect the USB cable item 5 that is built into the KVM cable of your MiniView Micro to the USB port on your computer Installation Step 3 Repeat Step 2 for your second computer Step 4 Turn the power of your computers on To switch between computers tap the Scroll Lock key twice Operations MiniView Micro allows you to access the computers through Hot Key comb
5. e set to simplify the installation Setup is fast and easy plugging cables into the appropriate ports is all that is entailed There is no software to configure and no imcompatibility problems Since the MiniView Micro intercepts keyboard input directly it works on virtually any hardware platform and with virtually all operating system The MiniView Micro USB KVM provides a convenient method to access the computers by simple Hot Key combinations from the keyboard e Use one keyboard monitor and mouse to control two computers Very compact KVM switch with molded cables for computer connections Supports Microsoft IntelliMouse and the scrolling wheel on most mice Easy to install No Software Required Easy to operate PC selection via convenient Hot Keys AutoScan function to monitor computer operation LED display for easy status monitoring Caps Lock Num Lock and Scroll Lock states are saved and restored when switching Hot pluggable add or remove computers without powering down the switch Keyboard and mouse emulation for error free PC booting Self Powered No need for external power supply Superior video quality up to 1920x1440 DDC DDC2 DDC2B Computers with a PS 2 mouse and keyboard connection VGA connection and an available USB port PS 2 connection USB port VGA connection Introduction 1 VGA port for the console monitor 2 PS 2 port for the console keyboard 3 P
6. inations from the keyboard 1 Selecting computers You can toggle between the two computers by pressing and releasing the Scroll Lock key twice Scroll Lock Scroll Lock 2 AutoScan Mode The MiniView Micro USB KVM offers AutoScan feature and allows you to monitor the activity of the connected computers without taking the trouble of switching yourself Operations con d To initiate the AutoScan mode press and release the left Shift key then press and release the right Shift key Left Shift Right Shift NOTE The interval between these two keys should be no more than 0 5 seconds Once the scanning begins it continues until you press the Space Bar to exit AutoScan Mode The port that was active at the time the scanning stopped would remain active Note While AutoScan Mode is in effect none of the keyboard keys except Space Bar will function You must exit AutoScan Mode by pressing the Space Bar in order to use the keyboard for other purposes d Operations con You can customize the scan interval time with the following Hot Key combination Left Shift Right Shift S n n represents a number from 1 to 4 which sets the desired scan interval as shown in the table below 3 seconds om Appendix LED Display Off Port is not selected On Steady Port is connected to an active computer Flashing is connected to an active computer and is being accessed in
7. nnections to make sure they are Fosse completely seated in the sockets Mouse needs to be Unplug the mouse from the Console Keyboard Port then plug it Mouse not detected reset back in or does not respond MiniView Micro Turn off computers Unplug the cables from the unit Wait five correctly needs to be reset seconds then plug the cables back in and turn the computers on ct M Check your Device Manager to be sure that the correct driver for rue ouse your mouse obtained from the manufacturer or supplied by the operating system has been installed Resolution and or Video Problems bandwidth settoo Select a lower resolution and or bandwidth high Technical Support If you need technical support please check out our IOGEAR Tech Info Library T I L at www iogear com support for the latest tips tricks and troubleshoot ing The IOGEAR T I L was designed to provide you with the latest technical information about our products Most of the answers to your questions can be found here so please try it out before contacting technical support Technical support is available Monday through Friday from 8 00 am to 5 00 pm PST and can be reached at 949 453 8782 or by email support iogear com Radio amp TV Interference Statement WARNING This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual ma
8. y cause interference to radio communications This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT DISK OR ITS DOCUMEN TATION EXCEED THE PRICE PAID FOR THE PRODUCT The direct vendor makes no warranty or representation expressed implied or statutory with respect to the contents or use of this documentation and especially disclaims its quality performance merchantability or fitness for any particular purpose The direct vendor also reserves the right to revise or update the device or documentation without obligation to notify any individual or entity of such revisions or updates For further inquires please contact your direct vendor e LJ Q 1E Am 23 Hubble Irvine CA 92618

Download Pdf Manuals

image

Related Search

Related Contents

  ppS® Flow+ ppS® Flow+ ppS® Flow+ ppS® Flow+  Version 3.3 User Manual  BCW710J取扱説明書  KING II / ATS / LS  Manuale di Installazione  Download(EN410)  Operating Instructions Model 270 Pressure Transducer  Betriebsanleitung - Indel - Elektronische Industriegeräte  BCT-2000 Software and BCT-128 and BCT  