Home
Intel SR2500AL User's Manual
Contents
1. TP02079 Figure 73 Replacing the Backup Battery 7 Dispose of the battery according to local ordinance 8 Remove the new lithium battery from its package and being careful to observe the correct polarity insert it in the battery socket 9 Close the chassis 10 Run Setup to restore the configuration settings to the RTC Intel Server System SR2500AL User s Guide 85 Replacing the Power Supply Caution The power supply is only hot swappable if you have a redundant system with two power supplies installed If you only have one power supply installed before removing or replacing the power supply you must first take the server out of service turn off all peripheral devices connected to the system turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet The power supply can be replaced if it fails or if one of the fans that is integrated into it fails To replace the power supply use the following instructions l Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all perip
2. B C D E F G H TP02081 A Mouse B Keyboard C Serial Port B RJ45 D NIC 1 10 100 1000 Mb E NIC 2 10 100 1000 Mb F Video G USB Port 6 H USB Port 5 Figure 7 Back Panel Connectors 12 Intel Server System SR2500AL User s Guide The NIC LEDs at the right and left of each NIC provide the following information Table 3 NIC LED Descriptions LED LED State Description Left Off No network connection Solid Amber Network connection in place Blinking Amber Transmit receive activity Right Off 10 Mbps connection if left LED is on or blinking Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection RAID Support The server system provides an embedded SATA controller that supports both 1 5 and 3 0 Gbps data transfer rates The BIOS Setup utility provides multiple drive configuration options on the Advanced ATA Controller setup page some of which affect the ability to configure RAID The Onboard SATA Controller option is enabled by default When this option is enabled the SATA Mode option can be set to either Legacy or Enhanced The Legacy and Enhanced modes affect the RAID configuration as follows Legacy supports four disk drives and does not provide RAID support Enhanced supports six disk drives and is required for RAID configurations Wh
3. Management Information On Board Platform Instrumentation only Intel Remote Management Module Control Panel Information Standard Control Panel Intel Local Control Panel Intel Server System SR2500AL User s Guide 125 Complete Problem Description In the space below provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found Please also include any details on troubleshooting already done 126 Intel Server System SR2500AL User s Guide Appendix D LED Decoder During the system boot process BIOS executes a number of platform configuration processes each of which is assigned a specific hex POST code number As each configuration routine is started BIOS will display the given POST code to the POST Code Diagnostic LEDs found on the back edge of the server board To assist in troubleshooting a system hang during the POST process the Diagnostic LEDs can be used to identify the last POST process to be executed Each POST code will be represented by a combination of colors from the four LEDs The LEDs are capable of displaying three colors green red and amber The POST codes are divided into two nibbles an upper nibble and a lower nibble Each bit in the upper nibble is represented by a red LED and each bit in the lower nibble is represented by a green
4. O I 9 I ae eE Ex O O Y X WV UTS R TP02071 Intel Server System SR2500AL User s Guide A BIOS Bank Select Jumper B Intel 6321ESB IO Controller C I O Expansion Module Hub Connector D POST Code Diagnostic LEDs E Intel Adaptive Slot Full F PCI Express Riser Slot Low Height Profile G System Identification LED H Back Panel I O Ports l Status LED Green Amber Blue J Serial B Configuration Jumper K System Fan 4 Header System Fan 3Header M DIMM Sockets N Intel 5000P MCH or Intel O Processor 1 Socket 5000X MCH P Processor 2 Socket Q Processor Fan 1 Header R Voltage Regulator Heat Sink S Processor Fan 2 Header T Bridge Board Connector U ATA 100 Optical Drive Connector Power IO V System Fan 2 Header W CPU Power Connector X Main Power Connector Y Battery Z Power Supply Management AA Dual Port USB 2 0 Header Connector BB System Fan 1 Header CC 24 pin SSI Control Panel DD SATA Port 0 Connector EE SATA Port 1 FF SATA Port 2 G
5. non 00000000 B c m E l g 200008 P Ir oo D a A D el 1 l j J HE jJ N A Power to Server Board Aux n n J e Power to Server Board Main AF000328 Power to Server Board CPU Power to Midplane Board 6 Power to Backplane Board Q RAID Battery to Active Midplane Board Figure 93 Cable Routing Fan Connections Use the figures below to determine the proper fan connections 7 N VAM i KG YA AQ AF000145 Figure 94 Connecting the Non redundant Fan Power Cables to the Passive Mid plane Board X A WAN ZA v Wi PS N N N NE TP02140 Intel Server System SR2500AL User s Guide Figure 95 Connecting the Redundant Fan Power Cables to the Active Mid plane Board 108 750W Single Power Supply Input Voltages 100 127V at 50 60 Hz 12 A max e 200 240V at 50 60 Hz 6 A max 750W Single Power Supply Output Voltages The table below lists the total wattage available from the power subsystem for each voltage Ensure that your loads do not exceed the combined total wattage of 750 Watts For information about calculating the power usage for your configuration see Calculating Power Usage Table 5 Power Supp
6. Note SATA connectors 6 a A Mid plane Power F Fan 4 Power B Fan 6 Power G Fan 3 Power C Fan 5 Power H Fan 1 Power D SATA 0 7 Connectors I Fan 2 Power E Bridge Board Connector J Backplane Connectors Figure 8 Passive Mid Plane Components nd 7 are not used in the Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP Intel Server System SR2500AL User s Guide AF000046 A RAID Battery Connector F Fan 4 Power B Mid plane Power Connector G FangPowr C Fan 6 Power H Fan 2 Power D Fan 5 Power Fan 1 Power E Bridge Board Connector J Backplane Connectors Figure 9 Active SAS SATA Mid Plane Components Intel Server System SR2500AL User s Guide 15 Hot Swap SAS SATA Backplane The backplane serves as an interface between the mid plane board and the system drives The following diagrams show the location for each connector found on the backplane AF000045 A Optical Drive Connector C Control Panel Connector B USB Floppy Connector D SAS SATA Connectors Figure 10 Hot Swap SAS SATA Backplane Components Front View 16 Intel Server System SR2500AL User s Guide AF000044 A Flex Bay Power D Backplane Power B Flex Bay Data C IDE Connector E Data Connectors one for the flex bay and one for the mid plane Figure 11 Hot Swap SAS SATA Backplane Components Rear View Intel Server Sy
7. Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide 67 Installing and Removing the Intel Remote Management Module and the Intel RMM NIC Installing the Intel RMM and Intel RMM NIC 68 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Squeeze the sides of the Intel RMM NIC module cover to disengage it from the server system back panel and remove it See letter A in the following figure A self adhesive foam gasket is required to protect the underside ofthe NIC module Remove the backing paper from the spacer and install as illustrated see letter B in the following figure Attach the standoffs to the server board see letter C in the following figure and attach the Intel RMM NIC module to the server board see letter D in the following figure Insert the standoff into the hole labeled TH4 on the Intel RMM board see letter E in the following figure The standoff installs on the bottom side of the Intel R
8. Intel Server System SR2500AL User s Guide Si el sistema ha estado en funcionamiento el microprocesador y el disipador de calor pueden estar a n calientes Tambi n conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores Existe peligro de explosi n si la pila no se cambia de forma adecuada Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo Para deshacerse de las pilas usadas siga igualmente las instrucciones del fabricante El sistema est dise ado para funcionar en un entorno de trabajo normal Escoja un lugar Limpio y libre de part culas en suspensi n salvo el polvo normal Bien ventilado y alejado de fuentes de calor incluida la luz solar directa e Alejado de fuentes de vibraci n e Aislado de campos electromagn ticos fuertes producidos por dispositivos el ctricos e En regiones con frecuentes tormentas el ctricas se recomienda conectar su sistema a un eliminador de sobrevoltage y desconectar el m dem de las l neas de telecomunicaci n durante las tormentas e Provisto de una toma de tierra correctamente instalada e Provisto de espacio suficiente como para acceder a los cables de alimentaci n ya que stos hacen de medio principal de desconexi n del sistema Chinese Intel Server System SR2500AL User s Guide
9. 4 AF000017 Figure 66 Installing the Backplane into the Server System Install hot swap drive carriers For instructions see Installing a SAS or SATA Hot swap Hard Disk Drive Install the mid plane board For instructions see Installing the Mid plane Board Intel Server System SR2500AL User s Guide 10 Connect necessary cables to the backplane 11 Install the server system cover For instructions see Installing the Server System Cover 12 Plug all peripheral devices and the AC power cable s into the server Installing and Removing the RAID Activation Key and the RAID Mini DIMM Installing the RAID Activation Key and the RAID Mini DIMM 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the server system cover For instructions see Removing the System Cover 4 Remove the large air baffle For instructions see Removing the Large Air Baffle Install the RAID activation key by pushing straight down see letter A in the figure below 6 Install the RAID mini DIMM by releasing the retention mechanism see letter B in the figure below and inserting the DIMM into the socket see letter C in the figure below AF000742 Figure 67 Installing the RAID Activation Key and the RAID Mini DIMM Intel Server Sys
10. Dopo aver seguito i sei passi di SICUREZZA sopracitati togliere le coperture del telaio del sistema come seque 1 Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture 162 Intel Server System SR2500AL User s Guide Per il giusto flusso dell aria e raffreddamento del sistema rimettere sempre le coperture del telaio prima di riaccendere il sistema Operare il sistema senza le coperture al loro proprio posto potrebbe danneggiare i componenti del sistema Per rimettere le coperture del telaio 1 Controllare prima che non si siano lasciati degli attrezzi o dei componenti dentro il sistema 2 Controllare che cavi dei supporti aggiuntivi ed altri componenti siano stati installati appropriatamente 3 Attaccare le coperture al telaio con le viti tolte in precedenza e avvitarle strettamente 4 Inserire e chiudere a chiave il lucchetto sul retro del sistema per impedire l accesso non autorizzato al sistema 5 Ricollegare tutti i cavi esterni e le prolunghe AC del sistema Se il sistema stato a lungo in funzione il microprocessore e il dissipatore di calore potrebbero essere surriscaldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio E consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se
11. Table 2 Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP Feature Summary Feature Description Dimensions 3 44 inches 87 30 mm high 16 93 inches 430 mm wide 27 75 inches 704 8 mm deep 65 pounds 29 5 kg max chassis weight Server Board Intel Server Board S5000PAL Processor See the nte Server Board S5000PAL S5000XAL Technical Product Specification for information on processor support Memory Eight DIMM slots supporting stacked DDR2 533 667 MHz FBDIMM memory Support for up to 32 GB DDR2 533 667 MHz FBDIMM memory Chipset Intel 5000P chipset consisting of Intel 5000P Memory Controller Hub MCH Intel 6321ESB I O Controller Hub Peripheral Interfaces External connections Stacked PS 2 ports for keyboard and mouse e RJ45 Serial B port Two RJ45 NIC connectors for 10 100 1000 Mb connections Two USB 2 0 ports Internal connections One USB port header which supports two USB 2 0 ports One DH10 Serial A header Six Serial ATA 150 connectors with integrated RAID 0 1 support One ATA 100 44 pin connector for optical drive support e SSI compliant 24 pin control panel header e SSI compliant 24 pin main power connector supporting the ATX 12V standard on the first 20 pins 1 O Controll National Semiconductor PC87427 controller Video On board ATI ES1000 video controller with 16 MB DDR SDRAM LAN Intel 82563EB dual port con
12. 161 Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell alimentazione di questo prodotto E possibile che il prodotto disponga di pi fonti di alimentazione Non modificare o utilizzare il cavo di alimentazione in c a fornito dal produttore se non corrisponde esattamente al tipo richiesto Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c a separato L interruttore attivato disattivato nel pannello anteriore non interrompe l alimentazione in c a del sistema Per interromperla necessario scollegare tutti i cavi di alimentazione in c a dalle prese a muro o dall alimentazione di corrente PASSI DI SICUREZZA Qualora si rimuovano le coperture del telaio per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del sistema 3 Togliere tutte le spine dei cavi del sistema dalle prese elettriche 4 Identificare e sconnettere tutti i cavi attaccati ai collegamenti I O od alle prese installate sul retro del sistema 5 Qualora si tocchino i componenti proteggersi dallo scarico elettrostatico SES portando un cinghia anti statica da polso che attaccata alla presa a terra del telaio del sistema qualsiasi superficie non dipinta 6 Non far operare il sistema quando il telaio senza le coperture
13. uL Ek nn nn nro 28 Intel Server System SR2500AL User s Guide xi xii Removing the Front Bezel eii eee uicina cte Print eee a 29 installing the Front B Z oa 30 Removing and Installing the System Cover nn 30 Removing the System Cover ete i theta rte tu endende 30 Installing the Server System Cover esses eene 31 Removing and Installing the Processor Air Duct nennen 32 Removing the Processor Air DUCL iet ee ie 32 Installing the Processor Air Duct sisi 34 Installing and Removing Memory estate mienne 35 Installing DIMMS T 35 Removing DIMMS d C k k n BA A 37 Installing the Processor zn 37 Installing the Heat S nk S ans AR 39 Removing a Processor unse ee 40 Removing and Installing the Small Air Baffle E Eek k 40 Removing the Small Air Baffle aussen 41 Installing the Small Air Baffle na ic 41 Removing and Installing the Large Air Baffle u Ek 42 Removing the Large Air Baffle EEE kk kK KK KK KA 42 Installing the Large Air Baffle u een 43 Installing and Removing a Hot swap Hard Drive EE Ek kk 44 Installing a SAS or SATA Hot swap Hard Disk Drive EE ene 44 Removing a SAS or SATA Hot swap Hard Disk Drive ELE eee 47 Installing or Removing a Slimline Optical Drive or Internal USB Floppy 47 Installing a Slimlin
14. Installing or removing jumpers A jumper is a small plastic encased conductor that slips over two jumper pins Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers If your jumpers do not have such a tab take care when using needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can damage the contacts inside the jumper causing intermittent problems with the function controlled by that jumper Take care to grip with but not squeeze the pliers or other tool you use to remove a jumper or you may bend or break the pins on the board Intel Server System SR2500AL User s Guide V vi Intel Server System SR2500AL User s Guide Preface About this Manual Thank you for purchasing and using the Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP This manual is written for system technicians who are responsible for troubleshooting upgrading and repairing this server system This document provides reference information feature information and step by step instructions on how to add and replace components on the server system For the latest version of this manual see http support intel com support motherboards server chassis SR2500 Manual Organization Chapter 1 provides a list of reference resources In this chapter you will find a list of techni
15. Intel Server System SR2500AL User s Guide 61 Installing a PCI Riser Card 1 8 9 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the processor air duct For instructions see Removing the Processor Air Duct Disconnect any cables attached to any add in cards Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Remove any add in cards from the PCI riser connector For instructions see Removing a PCI Add in Card Press the hold the blue riser locking lever see letter A in the figure below Place riser connector onto retention pins 10 Slide the riser connector to the left of the riser module to lock it into place see letter B in the figure below AF000147 Figure 54 Installing PCI Riser Card into the Server System 11 Release the blue locking lever 62 Intel Server System SR2500AL User s Guide 12 13 14 15 16 17 Installing Install the PCI add in card s if desired For instructions see Installing a PCI Add in Card Install the PCI riser assembly into the server system For instructions see Installing the PCI Riser Assembly Connect any cables to add in card
16. Note Make sure that all empty add in card slots have filler panels installed 10 11 12 13 Install the PCI riser assembly into the server system For instructions see Installing the PCI Riser Assembly Install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide 65 Installing and Removing the 1 0 Expansion Module s Installing the 1 0 Expansion Module s 66 1 10 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Squeeze the sides of the I O expansion module cover s to disengage it from the server system back panel and remove it See letter A in the figure below Attach the standoffs to the server board see letter B in the figure below and attach the I O expansion module s to the server board see letter C in the figure below BU Dual Gigabit AF000740 Figure 57 Installing the I O Expansion Module to the Serv
17. Remove any add in cards from the PCI riser connector For instructions see Removing a PCI Add in Card Push back on the blue release lever at the end of the riser connector see letter A in the figure below While holding the lever back push firmly on the edge of the board sliding it toward the right of the riser module to disengage the connector from the riser pins see letter B in the figure below and remove from the server system see letter C in the figure below Intel Server System SR2500AL User s Guide AF000326 Figure 53 Removing the PCI Riser Card from the Server System Full Height 10 1 m 12 13 14 15 16 Side Install the replacement riser connector if desired For instructions see Installing PCI Riser Card into the Server System Install the PCI add in card s if desired For instructions see Installing a PCI Add in Card Install the PCI riser assembly into the server system For instructions see Installing the PCI Riser Assembly Connect any cables to add in cards that require them See your add in card documentation for information and add in card requirements Re install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server
18. Ziehen Sie alle Kabel und alle an das System angeschlossenen Telekommunikationsleitungen ab Bewahren Sie alle Schrauben und anderen Befestigungselemente gut auf nachdem Sie die Geh useabdeckung entfernt haben Wenn Sie Ihre Arbeiten im Systeminneren beendet haben befestigen Sie die Geh useabdeckung mit den Originalschrauben bzw befestigungselementen F hren Sie keine Arbeiten im Netzteil aus Das Netzteil enth lt keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Schalten Sie den Server aus und ziehen Sie alle Netzkabel ab bevor Sie Komponenten ein oder ausbauen die nicht hot plug f hig sind Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netzkabel ab bevor Sie es aus dem Server ausbauen War Ihr Server in Betrieb k nnen die installierten Prozessoren und K hlk rper hei sein Sofern Sie keine Hot Plug Komponenten ein oder ausbauen warten Sie mit dem Abnehmen der Abdeckungen bis das System abgek hlt ist Gehen Sie beim Aus oder Einbauen von Hot Plug Komponenten sorgf ltig vor um nicht mit hei en Komponenten in Ber hrung zu kommen Ber hren Sie nicht die rotierenden L fterfl gel um Verletzungen zu vermeiden Falls Ihr System mit eine L fterabdeckung besitzt darf es nicht ohne diese Abdeckung betrieben werden Warnhinweise f r Racks Das Ger te Rack mu auf einer geeigneten festen Unterlage veranke
19. branchez tous les cordons d alimentation c a du syst me et des prises murales 4 Identifiez et d branchez tous les c bles reli s aux connecteurs d E S ou aux acc s derri re le syst me 5 Pour pr venir les d charges lectrostatiques lorsque vous touchez aux composants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Une fois TOUTES les tapes pr c dentes accomplies vous pouvez retirer les panneaux du syst me Proc dez comme suit 1 Si un cadenas a t install sur l arri re du syst me d verrouillez le et retirez le 2 Retirez toutes les vis des panneaux et mettez les dans un endroit s r 3 Retirez les panneaux Afin de permettre le refroidissement et l a ration du syst me r installez toujours les panneaux du bo tier avant de mettre le syst me sous tension Le fonctionnement du syst me en l absence des panneaux risque d endommager ses pi ces Pour installer les panneaux proc dez comme suit 1 Assurez vous de ne pas avoir oubli d outils ou de pi ces d mont es dans le syst me 2 Assurez vous que les c bles les cartes d extension et les autres composants sont bien install s 3 Revissez solidement les panneaux du bo tier avec les vis retir es plus t t 4 Remettez le cadenas en place et verrouillez le afin d
20. l een 101 Setup Menus ea ee eigener 101 Upgrading the BIOS cec T 103 Preparing for the Upgrade eU 103 Upgrading Me BIOS anna aeg 104 Clearing the Password una ee 104 Clearing the CMOS uu222220n4nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnennnn nen 105 Appendix A Technical Reference ss ssssssnnnnrsseeeeeeeennes 107 Cable Routing sua A des 107 Fan Connections E E ee re uen 108 750W Single Power Supply Input Voltages oooooccccnnncccccnnococcncnnnaccnnnannn cono kk kk kek nana 109 750W Single Power Supply Output Voltages E Ek kk k k kk k k kk 109 System Environmental Specifications kek kk ke kk K k kk 110 Appendix B Troubleshooting ine ee 111 Intel Server System SR2500AL User s Guide xiii Resetting the System nn nn 111 Problems following Initial System Installation esses 112 First Steps Checklist KHK neren 112 Hardware Diagnostic Testing senken en 112 Verifying Proper Operation of Key System Lights nn nnnnnnnnnnnnnnnnn nen 113 Confirming Loading of the Operating System uusssssnsenennsnnnnnnnnnnnnnnnnennnnennn nn 113 Specific Problems and Corrective Actions nn 113 Power Light Does Not Light ze aan 114 No Characters Appear On Screen ana 114 Characters Are Distorted or Incorrect LL LuE Ek ek
21. saved and Setup is exited If No is selected and the Enter key is pressed or the Esc key is pressed the user is returned to where they were before F10 was pressed without affecting any existing values Upgrading the BIOS The upgrade utility allows you to upgrade the BIOS in flash memory The code and data in the upgrade file include the following e On board system BIOS including the recovery code BIOS Setup Utility and strings e On board video BIOS and other option ROMs for devices embedded on the server board e OEM binary area Microcode A way to change the BIOS language Preparing for the Upgrade The steps below explain how to prepare to upgrade the BIOS including how to record the current BIOS settings and how to obtain the upgrade utility Note In the unlikely event that a BIOS error occurs during the BIOS update process a recovery process may need to be followed to return the system to service See Server System References for a link to necessary software and instrutions Recording the Current BIOS Settings 1 Boot the computer and press F2 when you see the message Press F2 Key if you want to run SETUP 2 Write down the current settings in the BIOS Setup program Note Do not skip step 2 You will need these settings to configure your server at the end of the procedure Intel Server System SR2500AL User s Guide 103 Obtaining the Upgrade Download the BIOS image
22. 73 23 EEC and EMC Directive 89 336 EEC The product has been marked with the CE Mark to illustrate its compliance VCCI Japan CORB HIRE EE EYANE j 23IN N VCCI DEM KEI lt SYIFSRANHENEETT lt O BE 2 RRERI CERT S CUN xi z 31 kn n 3 2 42800 3 31 C J3 kil N 25398 ARCET 245 ER d15 2 20180 21 English translation of the preceding notice This is a Class A product based on the standard of the Voluntary Control Council for Interference VCCI from Information Technology Equipment If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment according to the instruction manual BSMI END SRE FE ER ERAN HEEE HRH TRESERHATE TEA THEN ARAS He R L IK teji IM OR The BSMI Certification Marking and EMC warning is located on the outside rear area of the product 142 Intel Server System SR2500AL User s Guide Korean Compliance RRL Following is the RRL certification information for Korea Pj 24 ZH SZS Hays MERO MAA AEST o OA O N ror English translation of the notice above 1 Type of Equipment Model Name On License and Product 2 Certification No On RRL certificate Obtain certificate from local Intel representative Name of Certification Recipient Intel Corporation B Date of Manufacturer Refer to date code on product Manufacturer Nation Intel Corporation Refe
23. CIE Indica que no se deben tocar las aspas de los ventiladores ya que de lo contrario se podr an producir lesiones atra Indica que es necesario desenchufar los cables de alimentaci n de CA para ur ana desconectar la alimentaci n de CA Gra Recicle por favor la bater a P Aplicaciones y usos previstos Este producto ha sido evaluado como equipo de tecnolog a inform tica ITE que puede instalarse en oficinas escuelas salas de equipos inform ticos o lugares de mbito comercial similares Es posible que sea necesario llevar a cabo una evaluaci n adicional para comprobar si este producto es apropiado para otras categor as de productos y entornos adem s de las aplicaciones inform ticas por ejemplo soluciones m dicas industriales residenciales sistemas de alarma y equipos de pruebas Selecci n de la ubicaci n 182 El sistema se ha dise ado para funcionar en un entorno normal de oficinas Seleccione una ubicaci n que est Limpia seca y libre de macropart culas en suspensi n en el aire que no sean el polvo habitual de la habitaci n Bien ventilada y alejada de fuentes de calor incluida la luz solar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por dispositivos el ctricos En zonas propensas a tormentas el ctricas se recomienda que conecte el servidor a un supresor de sobretensiones y desconecte las l neas d
24. Carrier Note The slimline optical drive carrier can be used with an optional optical drive One slimline carrier is included with your server system the optical drive must be purchased separately You cannot install both an optical drive and a USB floppy drive The slimline optical drive carrier can be inserted or removed only when system power 1s turned off Drives in the optical drive carrier are NOT hot swappable For installation instructions on installing an optical drive see Installing or Removing a Slimline Optical Drive or Internal USB Floppy To use one of the drives provided by Intel use the following order codes Slimline CD ROM Drive AXXSCD Slimline DVD CDR Drive AXXDVDCDR The Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP does not support all slimline optical drives See Server System References for an Internet link to a list of supported hardware Intel provides accessory kits for these drives Advanced Management Options Intel Remote Management Module The Intel Remote Management Module is available to provide advanced server management features For installation instructions on installing the Intel Remote Management Module see the instructions provided with the management module Rack Mounted Systems Your Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP can be mounted into a rack Intel provides three options to mount this server into
25. Lisez attention toutes les consignes de s curit et les mises en garde indiqu es dans ce document avant de suivre toute instruction Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel Deployment Assistant CD ou bien rendez vous sur le site http support intel com support motherboards server sb cs 010770 htm Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precauci n de este documento antes de realizar cualquiera de las instrucciones Vea Intel Server Boards and Server Chassis Safety Information en el Intel Deployment Assistant CD y o en http support intel com support motherboards server sb cs 010770 htm HRS EPATIENITE EE HI TERRE PHU RER FIR RP ME http support intel com support motherboards server sb CS 010770 htm _ 4 Intel Server Boards and Server Chassis Safety Information Intel IC IE EK TIRE OGRE GEL o Intel Server System SR2500AL User s Guide Warnings Heed safety instructions Before working with your server product whether you are using this guide or any other resource as a reference pay close attention to the safety instructions You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL listing and other regulatory approvals of the p
26. No light indicates system identification is not activated H Power Sleep LED Continuous green light indicates the system has power applied to it Blinking green indicates the system is in S1 sleep state No light indicates the power is off is in ACPI S4 or S5 state Intel Server System SR2500AL User s Guide 19 Callout Feature Function l Power Sleep Button Continuous green light indicates a link between the system and the network to which it is connected Blinking green light indicates network activity J System Status LED Solid green indicates normal operation Blinking green indicates degraded performance Solid amber indicates a critical or non recoverable condition Blinking amber indicates a non critical condition No light indicates POST is running or the system is off K NIC 2 Activity LED Continuous green light indicates a link between the system and L NIC 1 Activity LED the network to which it is connected Blinking green light indicates network activity M Hard Disk Activity Random blinking green light indicates hard disk drive activity LED SAS or SATA No light indicates no hard disk drive activity N Reset Button Reboots and initializes the system O USB 2 0 Port Allows you to attach a USB component to the front of the system Figure 13 Intel Local Control Panel Bezels The optional front bezels provide a snap on design that allows for maximum airflow through the server chas
27. Table 9 POST Error Beep Code S usina is 120 Table 10 Error Beep Codes Generated by Intel Remote Management Module 121 Table 11 POST Progress Code LED Example essen 127 Table 12 Diagnostic LED POST Code Decoder lh h ddld kk kk kak kk kK K kak 128 Table 13 Product Regulatory Compliance Markings E kk kk kk 138 Table 14 Product Ecology Compliance Markings uuEEE kk kk kk k 144 Table 15 Other Markings sidad 146 Intel Server System SR2500AL User s Guide xxi xxii Intel Server System SR2500AL User s Guide Server System References Four product codes are associated with the Intel Server System SR2500AL SR2500ALLX SR2500ALBRP SR2500ALLXR SR2500ALBRPR Unless noted otherwise all references to the Intel Server System SR2500AL refer to all four product codes If you need more information about this product or information about the accessories that can be used with this server chassis use the following resources Table 1 Server System References For this information or software Use this Document or Software For in depth technical information about the server system including sub system overviews and mechanical drawings Inte Server Chassis SR2500 Technical Product Specification Found at http support intel com support motherboards server chassis SR2500 Inte Server Board S5000PAL Technical Product Specificat
28. a rack When installing the chassis into a rack Intel recommends you install systems from the bottom of the rack to the top In other words install the first system in the rack into the bottom position of the rack the second system in the second position from the bottom and so on Instructions for installing your chassis into a rack are included in the rail kit Intel Server System SR2500AL User s Guide 23 24 Intel Server System SR2500AL User s Guide 3 Hardware Installations and Upgrades Before You Begin Before working with your server product pay close attention to the Safety Information at the beginning of this manual Tools and Supplies Needed Phillips cross head screwdrivers 1 bit and 2 bit e Needle nosed pliers Antistatic wrist strap and conductive foam pad recommended System References All references to left right front top and bottom assume the reader is facing the front of the server system as it would be positioned for normal operation Removing and Installing from a Rack Three Intel rack options are available to install the Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP in a rack The options are the fixed bracket kit the basic rail kit and the tool less rail kit Only the tool less rail kit allows you to service the server system while installed in a rack The other rack options require the system to be removed from the rack before servicing Note
29. bles d alimentation ceux ci tant le seul moyen de mettre le systeme hors tension Espa ol El usuario debe abstenerse de manipular los componentes de la fuente de alimentaci n de este producto cuya reparaci n debe dejarse exclusivamente en manos de personal t cnico especializado Puede que este producto disponga de m s de una fuente de alimentaci n No intente modificar ni usar el cable de alimentaci n de corriente alterna si no corresponde exactamente con el tipo requerido El n mero de cables suministrados se corresponden con el n mero de fuentes de alimentaci n de corriente alterna que tenga el producto Intel Server System SR2500AL User s Guide 159 160 N tese que el interruptor activado desactivado en el panel frontal no desconecta la corriente alterna del sistema Para desconectarla deber desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentaci n INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el sistema presionando el interruptor encendido apagado 3 Desconecte todos los cables de alimentaci n CA del sistema o de las tomas de corriente alterna 4 Identifique y desconecte todos los cables enchufados a los conectores E S o a los puertos situados en la parte
30. cable s into the server Replacing the Control Panel The steps for replacing the standard control panel and the Intel Local Control Panel are nearly identical Use the steps below for both varieties of the control panel Where necessary differences between the two control panels are noted Your server must be operated with a control panel installed Caution The control panel is NOT hot swappable Before removing or replacing the control panel you must first take the server out of service turn off all peripheral devices connected to the system turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the front bezel if it is installed For instructions see Removing the Front Bezel 4 Remove the server system cover For instructions see Removing the System Cover Intel Server System SR2500AL User s Guide 89 5 Press the latch at the back of the control panel see letter A in the figure below 6 Slide the control panel out through the front of the server system see letter B in the figure below AF000005 Figure 79 Removing Standard Control Panel Module from the Server System 7 Slide the replacement control panel into the server system se
31. connect s au systeme 178 Intel Server System SR2500AL User s Guide Mettez toutes les vis ou autres attaches de c t lorsque vous retirez les panneaux d acc s Une fois que vous avez termin d acc der l int rieur du produit refixez le panneau d acc s avec les vis ou attaches d origine N essayez pas d acc der l int rieur du bloc d alimentation Il ne contient aucune piece reparable Renvoyez le au fabricant en cas de probl me Mettez le serveur hors tension et d branchez tous les cordons d alimentation avant d ajouter ou de remplacer tout composant non connectable chaud Lorsque vous remplacez le bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de retirer le bloc du serveur AA Attention Si le serveur a t utilis les processeurs et dissipateurs de chaleur install s peuvent tre chauds moins que vous n ajoutiez ou ne retiriez un composant connectable chaud laissez le syst me refroidir avant d ouvrir les panneaux Pour viter tout risque d entrer en contact avec un composant chaud lors d une installation chaud prenez toutes les pr cautions n cessaires lorsque vous retirez ou installez des composants connectables chaud AS Attention Pour viter de vous blesser ne touchez pas les pales de ventilateur en mouvement Si votre systeme est fourni avec une protection sur le ventilateur ne mettez pas le systeme en route sans
32. controller 0x79h G R A Disabling the console controller Ox7Ah G R A Enabling the console controller Keyboard PS2 or USB Ox90h R OFF OFF R Resetting the keyboard 0x91h R OFF OFF A Disabling the keyboard 0x92h R OFF G Detecting the presence of the keyboard Intel Server System SR2500AL User s Guide 129 130 Table 12 Diagnostic LED POST Code Decoder 0x93h R OFF G A Enabling the keyboard 0x94h R G OFF R Clearing keyboard input buffer 0x95h R G OFF A Instructing keyboard controller to run Self Test PS2 only Mouse PS2 or USB 0x98h A OFF OFF R Resetting the mouse Ox99h A OFF OFF A Detecting the mouse Ox9Ah A OFF G R Detecting the presence of mouse Ox9Bh A OFF G A Enabling the mouse Fixed Media OxBOh R OFF R R Resetting fixed media device OxBth R OFF A Disabling fixed media device OxB2h R OFF A Detecting presence of a fixed media device IDE hard drive detection etc OxB3h R OFF A A Enabling configuring a fixed media device Removable Media OxB8h A OFF R Resetting removable media device OxB9h A OFF R A Disabling removable media device OxBAh A OFF A R Detecting presence of a removable media device IDE CDROM detection etc OxBCh A G R R Enabling configuring a removable media device Boot Device Selection OxDO R R OFF R Trying boot
33. current and energy levels are present inside the power supply Return to manufacturer for servicing When replacing a hot plug power supply unplug the power cord to the power supply being replaced before removing it from the server To avoid risk of electric shock turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Power Cord Warnings Ifan AC power cord was not provided with your product purchase one that is approved for use in your country Caution To avoid electrical shock or fire check the power cord s that will be used with the product as follows Do not attempt to modify or use the AC power cord s if they are not the exact type required to fit into the grounded electrical outlets The power cord s must meet the following criteria The power cord must have an electrical rating that is greater than that of the electrical current rating marked on the product The power cord must have safety ground pin or contact that is suitable for the electrical outlet The power supply cord s is are the main disconnect device to AC power The socket outlet s must be near the equipment and readily accessible for disconnection The power supply cord s must be plugged into socket outlet s that is are provided with a suitable earth ground Intel Server System SR2500AL User s Guide 167 System Access Warnings Caution Cauti
34. de aire adecuadas compruebe que cuando sistema est funcionando las cubiertas de la carcasa est n instaladas Si utiliza el sistema sin las cubiertas podr a da ar sus componentes Para instalar las cubiertas Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema e Compruebe que los cables tarjetas adicionales y otros componentes est n instalados correctamente Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto 186 Intel Server System SR2500AL User s Guide Perif ricos o dispositivos l ser N Precauci n Para evitar el riesgo de la exposici n a radiaciones o de da os personales No abra la caja de ning n perif rico o dispositivo laser Los perif ricos o dispositivos l ser no pueden ser reparados por el usuario Haga que el fabricante los repare Intel Server System SR2500AL User s Guide 187 188 Intel Server System SR2500AL User s Guide
35. documentation that came with your tape drive for data cable connection information Comnect the 4 pin tape power cable to the tape drive Install the server system cover For instructions see Installing the Server System Cover Optional Install the front bezel For instructions see Installing the Front Bezel Plug all peripheral devices and the AC power cable s into the server Installing a Sixth Hard Drive Use the instructions below to install a hard drive in the sixth hard drive bay 1 54 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the front bezel if it is installed For instructions see Removing the Front Bezel Remove the server system cover For instructions see Removing the System Cover Slide the sixth HDD bracket into the backplane as shown in the figure below AF000012 Figure 47 Installing Sixth HDD Bracket Intel Server System SR2500AL User s Guide 6 The sixth hard drive kit comes with a power cable and two SATA cables Cabling for the sixth hard drive varies depending on which mid plane you have in your system If you have an active mid plane in your system go to step 7 for cabling instructions If you have a passive mid plane in your system go to step 8 for cabling instructions 7 If you have an active mi
36. drive CD ROM drive or DVD ROM drive The drives must be purchased separately The following figure shows the available options A oo0000 imimimimimimimim TP02126 Slimline Optical Drive Bay Tape Drive Filler Panel 6th HDD or Tape Drive Bay Optional Hard Disk Drive Bays HDD to Floppy Drive Conversion Optional m ojoj w gt Figure 15 Optional Peripherals Hard Disk Drives The server system ships with five drive carriers for installing five SAS or Serial ATA SATA hot swap drives Note SAS drives are supported on the Intel Server System SR2500ALLX SR2500ALLXR only One left drive bay can be converted to be used as a floppy bay To use the bay for a floppy drive the AXXFLOPHDDTRAY accessory kit must be used For instructions on installing hard drives see Installing and Removing a Hot swap Hard Drive Note Drives can consume up to 17 watts of power each Drives must be specified to run at a maximum ambient temperature of 45C Note The Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP does not support all SAS or Serial ATA SATA hard drives See Server System References for an Internet link to a list of supported hardware 22 Intel Server System SR2500AL User s Guide Slimline Optical Drive
37. identification is active ma No light indicates system identification is not activated H System Identification Solid blue indicates system identification is active Button No light indicates system identification is not activated Intel Server System SR2500AL User s Guide Callout Feature Function Reset Button Reboots and initializes the system J USB 2 0 Port Allows you to attach a USB component to the front of the chassis K NMI Button Puts the server in a halt state for diagnostic purposes L Video Port Allows you to attach a video monitor to the front of the chassis The front and rear video ports cannot be used at the same time Figure 12 Standard Control Panel Intel Local Control Panel The diagram below shows the features available on the Intel Local Control Panel B A C Ce 0D a An O l M L K J H G AF000031 Callout Feature Function A USB 2 0 Port Allows you to attach a USB component to the front of the chassis B LCD Display Screen on which system information is displayed C Menu Control Button Scroll up one option at a time Scroll Up D Menu Control Button Scroll down one option at a time Scroll Down E Menu Control Button Move to the previous option Scroll Left F Menu Control Button Select option Enter G System Identification Solid blue indicates system identification is active LED
38. if you install a processor that is inappropriate for your server See Server System References for a link to the list of compatible processor s Caution ESD and handling processors Reduce the risk of electrostatic discharge ESD damage to the processor by doing the following 1 Touch the metal chassis before touching the processor or server board Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor 2 Avoid moving around unnecessarily Caution Protective socket cover needs to be removed for proper cooling of the processor failure to remove the cover could result in damage to the system Installing the Processor To install a processor follow these instructions 1 2 Observe the safety and ESD precautions in Safety Information Turn off all peripheral devices connected to the server Turn off the server Intel Server System SR2500AL User s Guide 37 3 Disconnect the AC power cord s from the server 4 Remove the server s cover See the documentation that came with your server chassis for instructions on removing the server s cover 5 Locate the processor socket and raise the socket handle completely see Figure 26 TP02074 Figure 26 Lifting the Processor Socket Handle 6 Raise the CPU load plate see Figure 27 TP02075 Figure 27 Installing the Processor Note Do not touch the socket pins they are very sensitive and easi
39. la pila non viene sostituita in modo corretto Utilizzare solo pile uguali o di tipo equivalente a quelle consigliate dal produttore Per disfarsi delle pile usate seguire le istruzioni del produttore Il sistema amp progettato per funzionare in un ambiente di lavoro tipo Scegliere una postazione che sia Pulita e libera da particelle in sospensione a parte la normale polvere presente nell ambiente No Ben ventilata e lontana da fonti di calore compresa la luce solare diretta Al riparo da urti e lontana da fonti di vibrazione e Isolata dai forti campi magnetici prodotti da dispositivi elettrici In aree soggette a temporali consigliabile collegare il sistema ad un limitatore di corrente In caso di temporali scollegare le linee di comunicazione dal modem Dotata di una presa a muro correttamente installata Dotata di spazio sufficiente ad accedere ai cavi di alimentazione i quali rappresentano il mezzo principale di scollegamento del sistema Intel Server System SR2500AL User s Guide 163 164 Intel Server System SR2500AL User s Guide Appendix I Safety Information English Server Safety Information This document applies to Intel server boards Intel server chassis pedestal and rack mount and installed peripherals To reduce the risk of bodily injury electrical shock fire and equipment damage read this document and observe all warnings and precautions in this guide
40. la protection en place Avertissements sur le montage en rack Le rack doit tre fix a un support inamovible pour viter qu il ne bascule lors de Pextension d un serveur ou d un l ment de l quipement Le rack doit tre install conform ment aux instructions du fabricant Installez les quipements dans le rack en partant du bas en pla ant le plus lourd en bas du rack N tendez qu un seul l ment de l quipement partir du rack la fois Vous tes responsable de l installation d un disjoncteur principal d alimentation pour la totalit du rack Ce disjoncteur principal doit tre rapidement accessible et doit tre tiquet comme contr lant toute l unit et pas uniquement le ou les serveurs Pour viter tout risque d lectrocution le rack et chaque l ment de l quipement install dans le rack doivent tre correctement reli s la terre Intel Server System SR2500AL User s Guide 179 D charges lectrostatiques ESD Attention Les decharges lectrostatiques ESD peuvent endommager les lecteurs de disque dur les cartes et d autres pi ces Il est fortement conseill d effectuer l ensemble des procedures decrites a un poste de travail prot g contre les ESD Au cas ou aucun poste de ce type ne serait disponible prot gez vous contre les ESD en portant un bracelet antistatique reli la masse du ch ssis n importe quelle surface m tallique non peinte de votre serveur lorsq
41. of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation For questions related to the EMC performance of this product contact Intel Corporation 5200 N E Elam Young Parkway Hillsboro OR 97124 6497 1 800 628 8686 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and ifnot installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna ncrease the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected Consult the dealer or an experienced radio TV technicia
42. posterior del sistema 5 Cuando manipule los componentes es importante protegerse contra la descarga electrost tica ESD Puede hacerlo si utiliza una mu equera antiest tica sujetada a la toma de tierra del chasis o a cualquier tipo de superficie de metal sin pintar 6 No ponga en marcha el sistema si se han extra do las tapas del chasis Despu s de completar las seis instrucciones de SEGURIDAD mencionadas ya puede extraer las tapas del sistema Para ello 1 Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema si se ha instalado uno 2 Extraiga y guarde todos los tornillos de las tapas Extraiga las tapas Para obtener un enfriamiento y un flujo de aire adecuados reinstale siempre las tapas del chasis antes de poner en marcha el sistema Si pone en funcionamiento el sistema sin las tapas bien colocadas puede da ar los componentes del sistema Para instalar las tapas 1 Aseg rese primero de no haber dejado herramientas o componentes sueltos dentro del sistema 2 Compruebe que los cables las placas adicionales y otros componentes se hayan instalado correctamente 3 Incorpore las tapas al chasis mediante los tornillos extra dos anteriormente tens ndolos firmemente 4 Inserte el bloqueo de seguridad en el sistema y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema
43. rifier et maintenir la conformit avec les certifications et approbations de produit existantes Utilisez uniquement les composants d crits et r glement s sp cifi s dans ce guide L utilisation d autres produits composants annulera la liste UL et les autres approbations r glementaires du produit et le produit peut ne pas tre conforme aux autres lois et r glementations locales applicables au produit S urit avertissements et mises en garde Pour viter de vous blesser ou d endommager votre quipement lisez et respectez toutes les informations et consignes de s curit avant de commencer l installation du produit Les symboles de s curit suivants peuvent tre utilis s tout au long de cette documentation et peuvent figurer sur le produit ou sur son emballage Intel Server System SR2500AL User s Guide 175 ATTENTION Indique la pr sence d un risque pouvant entra ner des blessures physiques mineures ou endommager l g rement le mat riel si la mise en garde n est pas prise en compte AVERTISSEMEN Indique la pr sence d un risque pouvant entrainer des blessures corporelles graves si l avertissement n est pas pris en compte Indique un risque potentiel si les informations signal es ne sont pas prises en compte Indique des risques d lectrocution pouvant entra ner des blessures corporelles graves ou mortelles si les consignes de s curit ne sont pas respect es Signale des composants ou
44. see letter A If two processors are installed remove air dam see letter B by sliding slotted holes off duct pins Notes Do not remove the air dam if only one processor is installed Do not remove memory air deflector 34 TP02133 Figure 23 Removing the Processor 2 Air Dam Optional only if two processors are installed Place the processor air duct over the processor socket s See the figure below The front edge of the air duct should contact the fan module Use caution not to pinch or disengage cables that may be near or under the air duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide TP02132 Figure 24 Installing the Processor Air Duct Installing and Removing Memory The silkscreen on the board for the DIMMs displays DIMM Al DIMM A2 DIMM BI DIMM B2 DIMM C1 DIMM C2 DIMM D1 and DIMM D2 starting from the center of the board See Memory for a discussion of the memory requirements and options See Server System References for a link to the list of tested DIMMs Installing DIMMs To install DIMMs follow these steps 1 2 3 4 Observe the safety and ESD precautions in Safety Information Turn off all peripheral devices connected to the server Turn off the server Disconnect the AC power cord s from the server R
45. software Make sure all necessary files are installed Ifthe problems are intermittent there may be a loose cable dirt in the keyboard if keyboard input is incorrect a marginal power supply or other random component failures Ifyou suspect that a transient voltage spike power outage or brownout might have occurred reload the software and try running it again Symptoms of voltage spikes Intel Server System SR2500AL User s Guide include a flickering video display unexpected system reboots and the system not responding to user commands Note Random errors in data files Ifyou are getting random errors in your data files they may be getting corrupted by voltage spikes on your power line If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line you may want to install a surge suppressor between the power outlet and the system power cord Devices are not Recognized under Device Manager Microsoft Windows Operating System The Microsoft Windows operating systems do not include all of the drivers for the Intel chipsets onboard NICs and other components See Server System References for a link to the current drivers and chipset files Hard Drive s are not Recognized Check the following Make sure the drive is not disabled in BIOS Setup Make sure the drive is connected correctly and that is plugged into the power supply Make sure the drive is compatible
46. t verbunden sein w hrend eines elektrischen Sturms sollte keine Verbindung der Telekommunikationsleitungen mit dem Modem bestehen mit einer geerdeten Wechselstromsteckdose ausger stet sein ber ausreichend Platz verf gen um Zugang zu den Netzkabeln zu gew hrleisten da der Stromanschlu des Produkts haupts chlich ber die Kabel unterbrochen wird Francais Le bloc d alimentation de ce produit ne contient aucune piece pouvant tre r par e par l utilisateur Ce produit peut contenir plus d un bloc d alimentation Veuillez contacter un technicien qualifi en cas de probl me Ne pas essayer d utiliser ni modifier le c ble d alimentation CA fourni s il ne correspond pas exactement au type requis Le nombre de c bles d alimentation CA fournis correspond au nombre de blocs d alimentation du produit Notez que le commutateur CC de mise sous tension hors tension du panneau avant n teint pas l alimentation CA du syst me Pour mettre le syst me hors tension vous devez d brancher chaque c ble d alimentation de sa prise Intel Server System SR2500AL User s Guide 157 158 CONSIGNES DE S CURIT Lorsque vous ouvrez le boitier pour acc der l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s au syst me 2 Mettez le syst me hors tension en mettant l interrupteur g n ral en position OFF bouton poussoir 3 D
47. the Redundant Fan Module 96 Installing a Fan into the Redundant Fan Module nennen 96 Removing a Fan from the Fixed Fan Module EE 97 Intel Server System SR2500AL User s Guide Figure 88 Figure 89 Figure 90 Figure 91 Figure 92 Figure 93 Figure 94 108 Figure 95 Figure 96 Installing a Fan into the Fixed Fan Module ee 98 Installng The Rack Handle messen en 99 Removing the Rack Handle nennen 100 Clear Password Jumper serien 105 Clear CMOS JUMP r hr meet ennemie KK KAK KAK KK A dits 106 Cable no he r _oggb entente 107 Connecting the Non redundant Fan Power Cables to the Passive Mid plane Board Connecting the Redundant Fan Power Cables to the Active Mid plane Board 108 Diagnostic LED Placement Diagram m 128 Intel Server System SR2500AL User s Guide xix xx Intel Server System SR2500AL User s Guide List of Tables Table 1 Server System References ss 1 Table 2 Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP Feature SUMMA ee een ais 4 Table 3 NIC LED Descriptions SSL 13 Table 4 Setup Menu Key Use seen ca EXER 102 Table 5 Power Supply Output Capability ss 109 Table 6 System Environmental Specifications oonococccnnnccccnnnaccccnnnnccccnnnnnannncnnnn cnn nnnnnnccnnnns 110 Table 7 Resetting the System iue ceste ad ranger tunes 111 Table 8 LED Information seele 120
48. the backplane see letter B Verify that the blue release lever on the tray locks into place Optional For installing the optional USB floppy drive note the location of the backplane USB connector in Figure 39 see letter C and refer to the documentation that came with the device Intel Server System SR2500AL User s Guide TP02149 Figure 39 Installing an Optical Drive Assembly into the Server System 14 Install the server system cover For instructions see Installing the Server System Cover 15 Optional Install the front bezel For instructions see Installing the Front Bezel 16 Plug all peripheral devices and the AC power cable s into the server Removing a Slimline Optical Drive or Internal USB Floppy l Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the front bezel if it is installed For instructions see Removing the Front Bezel Remove the server system cover For instructions see Removing the System Cover If removing an internal USB floppy drive unplug it from the backplane Press the blue release lever see letter A to unlock the optical drive tray and remove the slimline optical drive tray assembly from the server system as shown in Figure 40 Intel Server System SR2500AL User s Guide 49 AF000151 Figure 40
49. to command the system to boot Before installing a PCI card you should always Turn off the server power by using the power button on the front of the system Unplug the AC power cord s from the server Problems with Newly Installed Application Software Problems that occur when you run new application software are usually related to the software not the server hardware Faulty equipment is unlikely especially 1f other software runs correctly Check the following Make sure the system meets the minimum hardware requirements for the software See the software documentation Make sure the software is properly installed and configured for the system See the software documentation Use only an authorized copy Unauthorized copies often do not work Ifyou are running the software from a CD ROM or DVD ROM try a different disk Make sure the correct device drivers installed Ifthe problems persist contact the software vendor s customer service representative Problems with Application Software that Ran Correctly Earlier 118 Problems that occur after the system hardware and software have been running correctly sometimes indicate equipment failure However they can also be caused by file corruption or changes to the software configuration Check the following Ifyou are running the software from a CD ROM or DVD ROM try a different disk Check your system for a virus infection Uninstall and reinstall the
50. to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region s in which the product is sold To help ensure EMC compliance with your local regional rules and regulations before computer integration make sure that the server system power supply and other modules have passed EMC testing using a server board with a microprocessor from the same family or higher and operating at the same or higher speed as the microprocessor used on this server board The final configuration of your end system product may require additional EMC compliance testing For more information please contact your local Intel representative This is an FCC Class A device Integration of it into a Class B system does not result in a Class B device Product Safety Compliance This server chassis product when correctly integrated per this guide complies with the following safety and electromagnetic compatibility EMC regulations Intended Application This product was evaluated as Information Technology Equipment ITE which may be installed in offices schools computer rooms and similar commercial type locations The suitability of this produ
51. 02128 Figure 21 Installing the Server System Cover Removing and Installing the Processor Air Duct Always operate your server system with the processor air duct in place The air duct is required for proper airflow within the server system For instructions on adding or replacing a processor first remove the processor air duct and then see your server board user guide for instructions on processor installations and removals Return to these instructions to reinstall the processor air duct after installing your processor and heat sink Removing the Processor Air Duct 32 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable Remove the server system cover For instructions see Removing the System Cover 4 Lift the processor air duct from its location over the two processor sockets Intel Server System SR2500AL User s Guide TP02131 Figure 22 Removing the Processor Air Duct 33 Intel Server System SR2500AL User s Guide Installing the Processor Air Duct 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Turn processor air duct over to reveal underside
52. 03 u nde Meu n C rrRD RUE R RUE RE DM ule MR nnne 142 Europe CE Declaration of Conformity u Eke ke 142 a APP din 142 IEEE e C 142 Korean Compliance RRL scende nee 143 i erwies c P TET 143 Product Ecology Compliance si 143 xiv Intel Server System SR2500AL User s Guide Regulated Specified Components oooocconnocccononaccccnononncnnnonnnnnnnnnannn kk ke kk K k kk 147 End of Life Product Recycling aussen 148 Appendix G Warianty une anne 149 Limited Warranty for Intel Chassis Subassembly Products sn nnnnn san 149 Appendix H Installation Assembly Safety Instructions 153 sire mr 153 DI US eT c a 155 FINE e O 157 R o AP re ee ee 159 AA E Ce nt ee Dee 161 Llc Wer rrr 162 Appendix l Safety Information sin 165 ENONSA e A n 165 Server Safety Information se ae a eR ss 165 Safety Warnings and Cautions sse 165 Intended Application USES isc 166 apo mete ee a ee 166 Equipment Handling Practices use eiii ete aea kK AA 166 Power and Electrical Warnings zes a 167 System ACCESS Warnings unseren nennen daran dede 168 Rack Mount Warnings aan 168 Electrostatic Discharge ESD si 169 Other HARAS nn oia 169 y ee 170 Sicherheitshinweise f r den Server uuuunssnsnsnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnannn 170 Sicherheitshinweis
53. 05 o Sen as r inl o O BMC Force na j li dl li j li al har ia Update Mode o o O gt O B Disable o O Password 29 1 B Reset Enable 310 310 T L J1D2 J1D1 i B o gt O Im 2 Clear al o CMOS i I ZT D J1D3 i O O O O TP02080 Figure 92 Clear CMOS Jumper 4 Wait five seconds 5 Return the CMOS Clear jumper to the CMOS Clear by BMC location covering pins l and 2 Close the server chassis 7 Reconnect the AC power and power up the system 8 The CMOS is now cleared and can be reset by going into the BIOS setup 106 Intel Server System SR2500AL User s Guide Appendix A Technical Reference Cable Routing When you add or remove components from your server system make sure your cables are routed correctly before reinstalling the server system cover Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked Use the figures below to determine the correct cable routing
54. 1 Mark requires to be applied to be retail product only Marking applied to bulk packaging and single packages Not applied to internal packaging such as plastics foams etc Intel Internal Specification All materials parts and subassemblies must not contain restricted materials as defined in Intel s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers http supplier intel com ehs environmental htm None Required Europe 144 Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC Mark applied to system level products only Intel Server System SR2500AL User s Guide Compliance Regional Description Europe Compliance Reference European Directive 2002 95 EC Restriction of Hazardous Substances RoHS Threshold limits and banned substances are noted below Quantity limit of 0 1 by mass 1000 PPM for Lead Mercury Hexavalent Chromium Polybrominated Biphenyls Diphenyl Ethers PBB PBDE Quantity limit of 0 01 by mass 100 PPM for Cadmium Compliance Reference Marking Example None Required Germany German Green Dot Applied to Retail Packaging Only for Boxed Boards Intel Internal Specification All materials parts and subassemblies must not contain restricted materials as defined in Intel s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers http supplie
55. 1 2 are jumpered the BIOS in the lower bank will be selected on the next reset These pins should be jumpered on 2 3 for normal operation Figure 4 BIOS Select Jumper Intel Server System SR2500AL User s Guide 10 BMC Force Update Mode Password Reset Jumper Name CMOS Clear o EE o y O Er a E er o E TP02080 Jumper Purpose If pins 2 3 are jumpered the CMOS settings will be cleared on the next reset These pins should be jumpered on 1 2 for normal operation Password Clear If pins 2 3 are jumpered administrator and user passwords will be cleared on the next reset These pins should be jumpered on 1 2 for normal operation BMC Force Update Mode If pins 2 3 are jumpered BMC Force Update Mode is enabled These pins should be jumpered on 1 2 for normal operation Figure 5 Recovery Jumpers Intel Server System SR2500AL User s Guide Intel Light Guided Diagnostics The server board contains diagnostic LEDs to help you identify failed and failing comp
56. 6 Intel Server System SR2500AL User s Guide Compliance Description Compliance Reference Compliance Reference Marking Example Ground Ground Connection Warnings Line1 Connection WARNING Swedish on line2 Apparaten skall anslutas till jordat uttag n r den ansluts till ett n tverk Finnish on line 3 Laite on liitettava suojamaadoituskoskettimilla varustettuun pistorasiaan English on line 4 Connect only to a properly earth grounded outlet Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and or declarations the following regulated components must be used and conditions adhered to Interchanging or use of other components will void the UL listing and other product certifications and approvals Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL http channel intel com go serverbuilder If you do not have access to Intel s Web address please contact your local Intel representative Server Chassis base chassis is provided with power supply and fans UL listed Server board you must use an Intel server board UL recognized Add in boards must have a printed wiring board flammability rating of minimum UL94V 1 Add in boards containing external power connectors and or lithium batteries must be UL recognized or UL listed Any add in board containi
57. Air Baffle sese 43 Figure 33 Installing the Large Air Baffle ss 44 Figure 34 Removing Hot swap Disk Carrier from the Server System 45 Figure 35 Removing Retention Device from Drive Carrier 45 Figure 36 Installing Hard Drive into Carrier 46 Figure 37 Install Drive Assembly into the Server System ooooooccccnncocccccooccccnnonncnccccnnnnncncnnnnco 46 Figure 38 Installing an Optical Drive into the Drive Tray 48 Figure 39 Installing an Optical Drive Assembly into the Server System 49 Figure 40 Removing the Slimline Optical Drive Assembly from the Server System 50 Figure 41 Removing the Slimline Optical Drive from the Tray E EEE UUUE 50 Intel Server System SR2500AL User s Guide xvii Figure 42 Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 57 Figure 58 Figure 59 Figure 60 70 Figure 61 Figure 62 Figure 63 Figure 64 Figure 65 Figure 66 Figure 67 Figure 68 Figure 69 Figure 70 Figure 71 Figure 72 Figure 73 Figure 74 Figure 75 Figure 76 Figure 77 Figure 78 Figure 79 Figure 80 Figure 81 Figure 82 Figure 83 Figure 84 Figure 85 Figure 86 Figure 87 xviii Installing Filler Blank into the
58. Check first to make sure you have not left loose tools or parts inside the system 2 Check that cables add in boards and other components are properly installed 3 Attach the covers to the chassis with the screws removed earlier and tighten them firmly 4 Insert and lock the padlock to the system to prevent unauthorized access inside the system 5 Connect all external cables and the AC power cord s to the system A microprocessor and heat sink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective gloves Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Dispose of used batteries according to manufacturer s instructions The system is designed to operate in a typical office environment Choose a site that is e Clean and free of airborne particles other than normal room dust Well ventilated and away from sources of heat including direct sunlight Away from sources of vibration or physical shock solated from strong electromagnetic fields produced by electrical devices n regions that are susceptible to electrical storms we recommend you plug your system into a surge suppresser and disconnect telecommunication lines to your modem during an electrical storm Provided with a p
59. Das vorliegende Dokument bezieht sich auf Intel Serverplatinen Intel Servergeh use Standfu und Rack sowie installierte Peripherieger te Es enth lt Warnungen und Vorsichtsma nahmen zur Vermeidung von Gefahren durch Verletzung Stromschlag Feuer und Besch digungen von Ger ten Lesen Sie diese Dokument daher sorgf ltig bevor Sie Ihr Intel Serverprodukt installieren oder warten Bei Widerspr chen zwischen den hier vorliegenden Angaben und den Informationen im Lieferumfang des Produkts oder auf der Website des betreffenden Produkts hat die Produktdokumentation Vorrang Die Integration und Wartung des Servers darf nur durch technisch qualifizierte Personen erfolgen Um die Einhaltung der vorhandenen Zulassungen und Genehmigungen f r das Produkt zu gew hrleisten sind die Richtlinien in diesem Handbuch sowie die Montageanleitungen in den Serverhandb chern zu beachten Verwenden Sie nur die beschriebenen zugelassenen Komponenten die im vorliegenden Handbuch angegeben werden Die Verwendung anderer Produkte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt Dadurch kann das Produkt gegen Produktbestimmungen versto en die im Verkaufsland gelten Sicherheitshinweise und Vorsichtsma nahmen 170 Um Verletzungen und Besch digungen zu vermeiden sollten Sie vor dem Beginn der Produktinstallation die nachfolgend aufgef hrten Sicherheitshinweise und informationen sorgf ltig lese
60. Follow all safety guidelines while removing a system from a rack to avoid injury Fixed Bracket Rack Mount Removal 1 Disconnect all cables from the back of the system Note Remember to use the system LED to properly identify the system you are servicing 2 Remove screws from the brackets and remove the system from the rack Fixed Bracket Rack Mount Installation 26 1 2 Fully extend a rail assembly the finger tab for the extension lock is revealed Press the finger tab and slide the inside rail from the middle rail until it completely separates Note The middle rail and outer rail cannot be separated 3 20 El Ne MA 10 11 12 13 14 15 16 17 18 19 20 21 Position an inside rail along one side of the chassis with the finger tab facing outward and located closer to the rear of the chassis Align the holes in the rail with the tabs on the chassis and place the rail against the chassis Slide the rail as far as it will go toward the front of the chassis to engage the tabs Fasten the rail to the chassis using one screw at the front of the chassis In the same manner attach the other inside rail to the other side of the chassis Using two screws attach one nut bar to the inside of the rack post Do not completely tighten the screws leave them loose enough to allow insertion of the brackets in the next step Insert the slotted foot of a rail bracket between each nut bar and
61. G SATA Port 3 HH SATA Port 4 lI SATA Port 5 JJ SATA SW RAID 5 Activation Key Connector KK Intel Remote Management LL System Recovery Jumpers MM Chassis Intrusion Switch Module RMM Connector Header NN 3 pin IPMB Header OO Intel Local Control Panel PP Serial A Header Header QQ Intel RMM NIC Connector Figure 3 Server Board Connector and Component Locations 8 Intel Server System SR2500AL User s Guide Configuration Jumpers o OA o A O m n i E 9 o o la o Q o mu BIOS Select m O O O O J3H1 j U 1 2 Force me O O_O Lower Bank E 3 A 2 3 Normal A O O O Operation Default a j N O O al O O O O TP02087 Jumper Name Jumper Purpose BIOS Select If pins
62. IMM 77 Installing the RAID Activation Key and the RAID Mini DIMM 77 Removing the RAID Activation Key and the RAID Mini DIMM j j 78 Installing and Removing the RAID Battery Backup Unit BBU UUEEEEEEUEUUU UUEUEUEUEE 79 Installing the RAID Battery Backup Unit kk kk kK 79 Removing the RAID Battery Backup Unit kk kk Kek 80 Installing and Removing the Server Board sse 81 Installing the Server Board ante en 81 Removing the Server Board is 82 Replacing the Backup Battery aussen ein kk kk aka kak kk kak kk KA KA kk kk kK kK KA A 84 Replacing the Power Supply iii 86 Replacing the Power Distribution Module kK KAYA 88 Replacing The Control Panel au a ee 89 Replacing a Fan Module met 91 Replacing a Redundant Fan Module 91 Replacing a Fixed Fan Module un eine biu iine EE 93 Replacing a Redundant System Fan iii 95 Replacing a Fixed Fall RC 97 Installing and Removing the Rack Handles nn 98 Installing the Rack Handles a essen 98 Removing the Rack Handles nee 99 Chapter 4 Server Utilities nina 101 Using the BIOS Setup Utility aan e banka b k NERA Muz BK DE 101 e ie 101 If You Cannot Access Setup xi si
63. Installing the Mid plane into the Server System EEE EEE 73 Installing the Bridge Board into the Server System ssessssssss 73 Removing the Backplane from the Server System 75 Installing the Backplane into the Server System ssssssssessss 76 Installing the RAID Activation Key and the RAID Mini DIMM 77 Removing the RAID Activation Key and the RAID Mini DIMM 78 Installing the RAID Battery Backup Unit 79 Removing the RAID Battery Backup Unit 80 Installing the Server Board nee ante kk kk kek kk Kek kK kK kk KHK 81 Removing the Server Board ener misiones 83 Replacing the Backup Battery siii rad 85 Removing Power Supply Filler Panel from the Server System 86 Removing Power Supply Module from the Server System 87 Installing Power Supply Module into the Server System 87 Installing Power Supply Filler Panel into the Server System 87 Removing the Power Distribution Module 88 Removing Standard Control Panel Module from the Server System 90 Installing Control Panel Module into the Server System 90 Removing the Redundant Fan Module KK 92 Installing the Redundant Fan Module 92 Removing the Fixed Fan Module 94 Installing the Fixed Fan Module 94 Removing a Fan from
64. Intel Server System SR2500AL User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number D31969 004 Disclaimer Information in this document is provided in connection with Intel products No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document Except as provided in Intel s Terms and Conditions of Sale for such products Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not designed intended or authorized for use in any medical life saving or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur Intel may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together It is the responsibility of the system integrator that choos
65. Kabel Erweiterungskarten sowie weitere Komponenten ordnungsgem angebracht sind Befestigen Sie die Abdeckungen am Geh use des Produkts wie in dessen Anleitung beschrieben Laser Peripherieger te oder Komponenten Caution Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hinweise e ffnen Sie keinesfalls das Geh use von Laser Peripherieger ten oder Laser Komponenten e Laser Peripherieger te oder Komponenten besitzen keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Francais Consignes de securite sur le serveur Ce document s applique aux cartes serveur Intel au ch ssis de serveur Intel sur pieds et sur rack et aux p riph riques install s Pour r duire les risques de dommages corporels d lectrocution d incendie et de dommages mat riels lisez ce document et respectez tous les avertissements et pr cautions mentionn s dans ce guide avant d installer ou de mettre jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livr es avec le produit ou publi es sur le site Web pour un produit particulier la documentation du produit prime Votre serveur doit tre int gr et entretenu uniquement par des techniciens qualifi s Vous devez suivre les informations de ce guide et les instructions d assemblage des manuels de serveur pour v
66. LED If both bits are set in the upper and lower nibbles then both red and green LEDs are lit resulting in an amber color If both bits are clear then the LED is off In the below example BIOS sends a value of ACh to the diagnostic LED decoder The LEDs are decoded as follows red bits 1010b Ah green bits 1100b Ch Since the red bits correspond to the upper nibble and the green bits correspond to the lower nibble the two are concatenated to be ACh Table 11 POST Progress Code LED Example 8h 4h 2h 1h LEDs Red Green Red Green Red Green Red Green ACh 1 1 0 1 1 0 0 0 Result Amber Green Red Off MSB LSB em ue Back edge of server board Diagnostic LEDs ZU UU MSB LSB Figure 96 Diagnostic LED Placement Diagram Table 12 Diagnostic LED POST Code Decoder Checkpoint Diagnostic LED Decoder Description GzGreen R Red A Amber MSB LSB Host Processor Ox10h OFF OFF OFF R Power on initialization of the host processor bootstrap processor 0x11h OFF OFF OFF A Host processor cache initialization including AP 0x12h OFF OFF G Starting application processor initialization 0x13h OFF OFF G A SMM initialization Chipset 0x21h OFF OFF R G Initializing a chipset component Memory 0x22h OFF OFF A OFF Reading configurati
67. MM board Intel Server System SR2500AL User s Guide 1 Attach the Intel RMM board to the server board connector and snap the standoff into the matching hole on the server board see letter F in the following figure AF000741 Figure 59 Installing the Intel RMM and the Intel RMM NIC Module to the Server System 2 Install the PCI riser assembly into the server system For instructions see Installing the PCI Riser Assembly 3 Install the processor air duct For instructions see Installing the Processor Air Duct 4 Install the server system cover For instructions see Installing the Server System Cover 5 Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide 69 Removing the Intel RMM and Intel RMM NIC 1 70 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Remove the Intel RMM board from the server board see letter A in the figure below Remove the Intel RMM NIC module from the server board see letter B in the figure below Remove t
68. OxEAh A R A OFF Flash Update OxEEh A A A OFF Calling Int 19 One beep unless silent boot is enabled OxEFh A A A G Unrecoverable boot failure S3 resume failure Runtime Phase EFI Operating System Boot OxF4h R A R R Entering Sleep state OxF5h R A R A Exiting Sleep state OxF8h A R R Operating system has requested EFI to close boot services ExitBootServices has been called OxF9h A R R A Operating system has switched to virtual address mode SetVirtualAddressMap has been called Intel Server System SR2500AL User s Guide 131 132 Table 12 Diagnostic LED POST Code Decoder OxFAh A R A R Operating system has requested the system to reset ResetSystem has been called Pre EFI Initialization Module PEIM Recovery 0x30h OFF OFF R R Crisis recovery has been initiated because of a user request Ox31h OFF OFF R A Crisis recovery has been initiated by software corrupt flash Ox34h OFF R Loading crisis recovery capsule 0x35h OFF Handing off control to the crisis recovery capsule Ox3Fh G A Unable to complete crisis recovery Intel Server System SR2500AL User s Guide Appendix E Getting Help World Wide Web http support intel com support motherboards server chassis SR2500 Telephone All calls are billed per incident levied in local currency at the applicable credit card exchange rate plus appl
69. Removing the Slimline Optical Drive Assembly from the Server System 7 Press downward on the side of the tray see letter A and disengage the drive from the two metal tabs on the opposite side of the tray see letter B 8 Lift up on the optical drive see letter C to remove it from the tray AF000152 Figure 41 Removing the Slimline Optical Drive from the Tray 50 Intel Server System SR2500AL User s Guide 9 Ifno device will be installed in this location install a filler blank as shown in Figure 42 AF000155 Figure 42 Installing Filler Blank into the Server System 10 Install the server system cover For instructions see Installing the Server System Cover 11 Optional Install the front bezel For instructions see Installing the Front Bezel 12 Plug all peripheral devices and the AC power cable s into the server Installing a Tape Drive To install a tape drive into your server system your system must meet the following requirements You must purchase the tape drive kit order number ADRTAPEKIT You must purchase a 3 5 inch tape drive You must have an add in card that supports a tape drive After purchasing the tape drive kit and the tape drive use the instructions below to install them In addition to these instructions refer to the instructions that came with your tape drive for additional requirements 1 Observe the safety and ESD precautions at the begin
70. S SATA Backplane Components Rear Viev 17 Figure 12 Standard Control Panel a a ee 19 Figure 13 Intel Local Control Panel 20 Figure 14 Server System Back se 21 Figure 15 Optional Peripherals iios iso Pre EcL gioi oo 22 Figure 16 Front Bezel Supporting the Standard Control Panel 28 Figure 17 Front Bezel Supporting the Intel Local Control Panel 28 Figure 18 Removing the Front Bezel si 29 Figure 19 Installing the Front Bezel an sn ar 30 Figure 20 Removing the Server System Cover 31 Figure 21 Installing the Server System Cover 32 Figure 22 Removing the Processor Air Duct en 33 Figure 23 Removing the Processor 2 Air Dam Optional only if two processors are installed 34 Figure 24 Installing the Processor Air Duct nr nccnnnnnnns 35 Figure 25 Installing the Memory scsi 36 Figure 26 Lifting the Processor Socket Handle E Ek kk keke 38 Figure 27 Installing the Process 38 Figure 28 Removing the Socket Cover sis 39 Figure 29 Installing the Heat Sink 2U Passive Heat Sink Shown sssss 39 Figure 30 Removing the Small Air Baffle ssseeeeenmmm e 41 Figure 31 Installing the Small Air Baffle nn ne 42 Figure 32 Removing the Large
71. See Server System References for a link to the tested drives Make sure you have not exceeded the power budget for the server See Server System References for a link to software to check your power budget Ifusing SCSI drives verify that each SCSI ID number is unique on the SCSI bus See your drive documentation for details on setting the SCSI ID for your drives Ifusing ATA drives verify that the master slave settings are set correctly See your drive documentation for details on setting the master slave settings e Ifusing a RAID configuration with SCSI or SATA drives make sure the RAID card is installed correctly Bootable CD ROM Disk Is Not Detected Check the following Make sure the BIOS is configured to allow the CD ROM to be the first bootable device Intel Server System SR2500AL User s Guide 119 LED Information The Intel Server Board S5000PAL includes LEDs that can aid in troubleshooting your system A table of these LEDs with a description of their use is listed below Table 8 LED Information LED Name Function Location LED Color Notes Power Indicates system power Front control Green Off Power is off or in sleep is on or off panel state S5 On Power is on or in sleep stats SO ID Aid in server Front control Blue Press ID LED button or use identification from the panel and Server Management software back panel board rear left to turn the LED on and off corner System Visible fa
72. Server System ssseessseeeeee 51 Removing Tape Drive Filler Panel from the Server System 52 Removing Sixth Drive Filler Panel from the Server System 52 Inserting a Tape Drive into the Carrier en 53 Installing Tape Drive Assembly into the Server System 53 Installing Sixth HDD Bracket E arcaica 54 Installing Power and SATA Cables Active Mid Plane Installed 55 Installing Power and SATA Cables Passive Mid Plane Installed 56 Installing the Filler Panels ur e a Ec a 57 Removing PCI Riser Assembly from the Server System 58 Installing PCI Riser Assembly into the Server System 59 Removing the PCI Riser Card from the Server System Full Height Side 61 Installing PCI Riser Card into the Server System 62 Installing a Full Height Add In Card 64 Removing a Full Height Add In Card kk kk KS 65 Installing the I O Expansion Module to the Server Board 66 Removing the I O Expansion Module s from the Server Board 67 Installing the Intel RMM and the Intel RMM NIC Module to the Server System 69 Removing the Inte RMM and the Intel RMM NIC Module from the Server System Removing the Bridge Board from the Server System 71 Removing the Mid plane from the Server System 72
73. TE 181 Informaci n de seguridad del servidor LLEE kk kk kek 181 Advertencias y precauciones sobre seguridad EL Ek 181 Aplicaciones y USOS previstos sais kn 182 Selecci n de la ubicaci n iii 182 Manipulaci n del equipo isses o auk oM x kk k k kk K k A K KA KK 183 Advertencias de alimentaci n y el ctricas EEE e 183 Advertencias sobre el cable de alimentaci n E e 183 Advertencias el acceso al sistema E EEE kk KK KK KAKA 184 Advertencias sobre el montaje en bastidor E u Ek 185 Descarga electrost tica ESD asie da 185 a c 186 Intel Server System SR2500AL User s Guide List of Figures Figure 1 Intel Integrated Server System SR2500AL E kk kk kk kek kek kk 3 Figure 2 ChassisComponents anne elek 6 Figure 3 Server Board Connector and Component Locations EE EEE 8 Figure 4 BIOS Select Jumper a ee 9 Figure 5 Recovery JUMpers sust kk lt AA KA kk KIR AK A A 10 Figure 6 Light Guided Diagnostic LEDS EE kk kk kek kk nennen 11 Figure 7 Back Panel COnleolOES cuesta een ernennen kk kek Ka KK tete KK KRA 12 Figure 8 Passive Mid Plane Components 14 Figure 9 Active SAS SATA Mid Plane Components ooocccocccococcccconnccnnonancccnnnnnn cnc kk kek k k k 15 Figure 10 Hot Swap SAS SATA Backplane Components Front Viev 16 Figure 11 Hot Swap SA
74. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt batteri returneres apparatleveranderen Explosionsfara vid felaktigt batteribyte Anv nd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera anv nt batteri enligt fabrikantens instruktion Paristo vol r j ht jos se on virheellisesti asennettu Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin H vit k ytetty paristo valmistajan ohjeiden mukaisesti Intel Server System SR2500AL User s Guide Observe the safety and ESD precautions in Safety Information Turn off all peripheral devices connected to the server Turn off the server Disconnect the AC power cord s from the server S D Dr 5 Remove the server s cover and locate the battery See the documentation that came with your server chassis for instructions on removing the server s cover 5 Insert the tip of a small flat bladed screwdriver or an equivalent under the tab in the plastic retainer Gently push down on the screwdriver to lift the battery 6 Remove the battery from its socket
75. a 134 Argentina Contact AT amp T USA at 0 800 222 1288 Once connected dial 800 843 4481 Brazil 001 916 377 0180 Chile Easter Island Contact AT amp T USA at 800 800 311 Once connected dial 800 843 4481 Mainland and Juan Contact AT amp T USA at 800 225 288 Once connected dial 800 843 4481 Intel Server System SR2500AL User s Guide Colombia Contact AT amp T USA at 01 800 911 0010 Once connected dial 800 843 4481 Costa Rica Contact AT amp T USA at 0 800 0 114 114 Once connected dial 800 843 4481 Ecuador Andimate Contact AT amp T USA at 1 999 119 Once connected dial 800 843 4481 Pacifictel Contact AT amp T USA at 1 800 225 528 Once connected dial 800 843 4481 Guatemala Contact AT amp T USA at 99 99 190 Once connected dial 800 843 4481 Mexico Contact AT amp T USA at 001 800 462 628 4240 Once connected dial 800 843 4481 Miami 1 800 621 8423 Panama Contact AT amp T USA at 00 800 001 0109 Once connected dial 800 843 4481 Paraguay 001 916 377 0114 Peru 001 916 377 0114 Uruguay 001 916 377 0114 Venezuela Contact AT amp T USA at 0 800 2255 288 Once connected dial 800 843 4481 Intel Server System SR2500AL User s Guide 135 136 Intel Server System SR2500AL User s Guide Appendix F Regulatory and Compliance Information Product Regulatory Compliance Warning To ensure regulatory compliance you must adhere
76. a una Intel Server System SR2500AL User s Guide 185 disponible prot jase de alguna forma contras las descargas llevando un brazalete antiest tico conectado a la toma de tierra de la carcasa cualquier superficie de metal que no est pintada del servidor cuando manipule las piezas Manipule siempre las tarjetas con el m ximo cuidado Pueden ser sumamente sensibles a las descargas electrost ticas Suj telas s lo por los bordes Una vez extraida la tarjeta de su envoltorio de protecci n o del servidor col quela con el lado de los componentes hacia arriba sobre una superficie con toma de tierra y sin carga est tica Utilice una almohadilla de espuma conductora si dispone de ella pero nunca el envoltorio de la tarjeta No deslice la tarjeta sobre ninguna superficie Otros riesgos Sustituci n de la bater a A Precauci n Existe el peligro de explosi n si la bater a no se reemplaza correctamente Al reemplazar la bater a utilice s lo la bater a recomendada por el fabricante del equipo Deseche las bater as respetando la normativa local No intente recargar la bater a No intente desmontar pinchar o causar cualquier otro desperfecto a una bater a Enfriamiento y circulaci n de aire Precauci n El tendido de los cables debe realizarse cuidadosamente tal y como se le indica para reducir al m nimo los problemas de obstrucci n de la ventilaci n y de refrigeraci n Para conseguir una refrigeraci n y corriente
77. able s into the server Installing and Removing a Hot swap Hard Drive Up to six hot swap SAS or SATA drives can be installed Cautions If you install less than six drives or devices empty drive bays must be occupied by carriers with baffles to maintain proper system cooling To avoid possible damage to your server system do not use older style drive carriers Note The server system does not support all hard drives See Server System References for an Internet link to a list of supported hardware Installing a SAS or SATA Hot swap Hard Disk Drive 1 Remove the front bezel if it is installed For instructions see Removing the Front Bezel 2 Open the latch at the front of the hard drive carrier See letter A in the figure below 44 Intel Server System SR2500AL User s Guide 3 Pull out on the black lever and slide the carrier from the server system See letter B in the figure below TPO2141 Figure 34 Removing Hot swap Disk Carrier from the Server System 4 Remove the four screws that attach the plastic retention device or the previously installed hard drive to the drive carrier Two screws are at each side of the retention device or the hard drive Store the plastic retention device for future use TP02142 Figure 35 Removing Retention Device from Drive Carrier Remove the hard drive from its wrapper and place it on an antistatic surface 6 Set any jumpers and or switches on the drive a
78. are not shared with other PCI drivers For these drivers it may be necessary to alter settings so that interrupts are not shared See the documentation that came with your PCI card s for information on changing interrupts Diagnostics pass but the connection fails Make sure the network cable is securely attached Make sure you specify the correct frame type in your NET CFG file The controller stopped working when an add in adapter was installed Make sure the cable is connected to the port from the onboard network controller Make sure your BIOS is current See Server System References for a link to the current version Make sure the other adapter supports shared interrupts Make sure your operating system supports shared interrupts Try reseating the add in adapter The add in adapter stopped working without apparent cause Reseat the adater Put the adapter in a different slot The network driver files may be corrupt or deleted Delete and then reinstall the drivers e Run diagnostics Intel Server System SR2500AL User s Guide 117 System Boots when Installing PCI Card System Management features require full time standby power This means some parts of the system have power going to them whenever the power cord is plugged in even 1f you have turned the system power off with the power button on the front panel If you install a PCI card with the AC power cord plugged in a signal may be sent
79. arge Air Baffle Install the bridge board For instructions see Figure 64 Installing the Bridge Board into the Server System on page 73 Install the optical drive cable optional Install the PCI riser assembly For instructions see Installing the PCI Riser Assembly Install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide 83 Replacing the Backup Battery 84 Warning Advarsel Advarsel Varning Varoitus The lithium battery on the server board powers the RTC for up to 10 years in the absence of power When the battery starts to weaken it loses voltage and the server settings stored in CMOS RAM in the RTC for example the date and time may be wrong Contact your customer service representative or dealer for a list of approved devices Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Discard used batteries according to manufacturer s instructions Lithiumbatteri Eksplosionsfare ved fejlagtig h ndtering Udskiftning m kun ske med batteri af samme fabrikat og type Lev r det brugte batteri tilbage til leveranderen Lithiumbatteri Eksplosjonsfare
80. arrier Pull out on the black lever to slide the carrier from the server system 4 Remove the four screws that attach the hard drive to the drive carrier Lift the drive from the carrier Store the drive in an anti static bag 5 If you are not installing a new drive place the plastic retention device into the drive carrier using the four screws you removed from the hard drive 6 Insert the screws that held the drive in the carrier into the screw locations on the carrier for future use 7 With the black lever in the fully open position slide the drive carrier into the server system The green latch must be to the right Do not push on the black lever until the lever begins to close by itself Note For proper airflow the hard drive carrier must be replaced in the server system even ifno hard drive is installed in it 8 When the black lever begins to close by itself push on it to lock the drive carrier into place 9 Install the server system cover For instructions see Installing the Server System Cover 10 Optional Install the front bezel For instructions see Installing the Front Bezel 11 Plug all peripheral devices and the AC power cable s into the server Installing or Removing a Slimline Optical Drive or Internal USB Floppy Cautions Slimline optical drives are NOT hot swappable Before removing or replacing the drive you must first take the server out of service turn off all peripheral devices c
81. as fuentes de alimentaci n de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje Para evitar riesgos de choques electricos use precauci nes al trabajar con las fuentes de alimentaci n que utilizan el polo neutral de fuselaje No intente modificar ni utilizar un cable de alimentaci n de CA si no es del tipo exacto requerido Se necesita un cable de CA para cada fuente de alimentaci n del sistema La fuente de alimentaci n de este producto no contiene piezas que puedan ser reparadas por el usuario No abra la fuente de alimentaci n Dentro de la fuente de alimentaci n puede haber niveles de tensi n corriente y energ a peligrosos Devu lvala al fabricante para repararla Al reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de la fuente de alimentaci n que va a reemplazar antes de extraerla del servidor Para evitar el riesgo de descargas el ctricas antes de abrir el servidor ap guelo desconecte el cable de alimentaci n los sistemas de telecomunicaciones las redes y los m dems conectados al mismo Advertencias sobre el cable de alimentaci n Si no se ha proporcionado con el producto ning n cable de alimentaci n de CA adquiera alguno cuyo uso est aprobado en su pa s Intel Server System SR2500AL User s Guide 183 AA Precauci n Para evitar descargas el ctricas o fuego revise los cables de alimentaci n que usar con el produc
82. before installing or maintaining your Intel server product In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product the product documentation takes precedence Your server should be integrated and serviced only by technically qualified persons You must adhere to the guidelines in this guide and the assembly instructions in your server manuals to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s in which the product is sold Safety Warnings and Cautions To avoid personal injury or property damage before you begin installing the product read observe and adhere to all ofthe following safety instructions and information The following safety symbols may be used throughout the documentation and may be marked on the product and or the product packaging CAUTION Indicates the presence of a hazard that may cause minor personal injury or property damage if the CAUTION is ignored WARNING Indicates the presence of a hazard that may result in serious personal injury if the WARNING is ignored Indicates potential hazard if indicated information is ignored I
83. ber blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Intel Server System SR2500AL User s Guide 155 SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripherieger te aus 2 Schalten Sie das System mit dem Hauptschalter aus 3 Ziehen Sie den Stromanschlu stecker Ihres Systems aus der Steckdose 4 Auf der R ckseite des Systems beschriften und ziehen Sie alle Anschlu kabel von den I O Anschl ssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD ber blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten installiert werden Ein Betrieb des Systems ohne angebrachte Abdeckung kann Ihrem System oder Teile darin besch digen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten auf ordnungsgem en Sitz und Installation 3 Bringen Sie die Abdeckungen wieder am Ge
84. box is it switched to the correct system Intel Server System SR2500AL User s Guide Are the brightness and contrast controls on the video monitor properly adjusted Is the video monitor signal cable properly installed Does this video monitor work correctly if plugged into a different system Is the onboard video controller enabled in the BIOS Remove all add in cards and see if the video returns If successful add the cards back in one at a time with a reboot between each addition Make sure the memory DIMMs comply with the system requirements Make sure the memory DIMMs have been populated according to the system requirements Remove the memory DIMMs and re seat them Make sure the processor s comply with the system requirements Make sure the processor s have been populated according to the system requirements Remove the processor s and re seat them If you are using an add in video controller board do the following 1 2 3 4 Verify that the video works using the onboard video controller Verify that the video controller board is fully seated in the server board connector Reboot the system for changes to take effect If there are still no characters on the screen after you reboot the system and POST emits a beep code write down the beep code you hear This information is useful for your service representative If you do not receive a beep code and characters do not appear the video display monitor or
85. cal documents that give additional details on the Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP and the location where they can be found Chapter 2 provides a brief overview of the server system In this chapter you will find a list ofthe server system features illustrations of the product and product diagrams to help you identify components and their locations Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system This includes how to navigate through the BIOS Setup screens how to perform a BIOS update and how to reset the password or CMOS Information about the specific BIOS settings and screens is available in the Intel 5000 Series Chipsets Server Board Family Datasheet See Server System References for a link to the Intel 5000 Series Chipsets Server Board Family Datasheet Chapter 4 provides instructions on adding and replacing components Use this chapter for step by step instructions and diagrams for installing or replacing components such as the fans power supply drives and other components At the back of this manual you will find technical specifications regulatory information getting help information and the warranty Product Contents The Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP ships with the Intel Server Board SSOOOPAL For further information see the Intel Ser
86. ccording to the drive manufacturer s instructions 7 With the drive circuit side down position the connector end of the drive so that it is facing the rear of the drive carrier 8 Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the plastic retention device Intel Server System SR2500AL User s Guide 45 10 11 12 13 46 TP02143 Figure 36 Installing Hard Drive into Carrier With the black lever in the fully open position slide the drive assembly into the server system The green latch at the front of the drive carrier must be to the right Do not push on the black drive carrier lever until the lever begins to close by itself When the black drive carrier lever begins to close by itself push on it to lock the drive assembly into place TP02144 Figure 37 Install Drive Assembly into the Server System Install the server system cover For instructions see Installing the Server System Cover Optional Install the front bezel For instructions see Installing the Front Bezel Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide Removing a SAS or SATA Hot swap Hard Disk Drive 1 Remove the front bezel if it is installed For instructions see Removing the Front Bezel 2 Press in on the green latch at the front of the hard drive c
87. ckup Unit BBU Installing the RAID Battery Backup Unit 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the server system cover For instructions see Removing the System Cover 4 Remove the large air baffle For instructions see Removing the Large Air Baffle Insert the RAID battery backup unit into the server system and slide back until it locks into place as shown in the figure below see letter A 6 Attach the cable from the rear of the RAID battery backup unit to the mid plane board as shown see letter B AF000149 Figure 69 Installing the RAID Battery Backup Unit 7 Install the large air baffle For instructions see Installing the Large Air Baffle 8 Install the server system cover For instructions see Installing the Server System Cover Intel Server System SR2500AL User s Guide 79 9 Plug all peripheral devices and the AC power cable s into the server Removing the RAID Battery Backup Unit l 80 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the large air baffle For instructions
88. ct for other product categories and environments such as medical industrial telecommunications NEBS residential alarm systems test equipment etc other than an ITE application may require further evaluation Product Regulatory Compliance References The following table references Server Chassis Compliance and markings that may appear on the product Markings below are typical markings however may vary or be different based on how certification is obtained Note Certifications Emissions requirements are to Class A Table 13 Product Regulatory Compliance Markings Compliance Regional Compliance y Description Relaconce Compliance Reference Marking Example Australia New Zealand AS NZS 3548 Emissions v N232 Argentina IRAM Certification Safety W Belarus Belarus None Required Certification Canada USA CSA 60950 UL 60950 Safety d Canada USA Industry Canada CANADA ICES 003 CLASS A ICES 003 Emissions CANADA NMB 003 CLASSE A FCC This device complies with Part 15 ofthe FCC Rules Operation f this device is subject to the following tw ditions CFR 47 Part 15 1 This device may not cause harmful interference and Emissions 2 This device must accept any interference received including interference that may cause undesired operation Manufactured by Intel Corporation China CNCA CB4943 Safety GB 9254 Emissions GB17625 Harmonics Intel Ser
89. ctor sockets the wrong way Drive Activity Light Does Not Light Check the following e Are the drive s power and signal cables properly installed Are all relevant switches and jumpers on the drive set correctly Is the drive properly configured e Is the drive activity light always on If so the signal cable may be plugged in incorrectly CD ROM Drive or DVD ROM Drive Activity Light Does Not Light Check the following Are the CD ROM DVD ROM drive s power and signal cables properly installed Are all relevant switches and jumpers on the drive set correctly Is the drive properly configured Cannot Connect to a Server Make sure the network cable is securely attached to the correct connector at the system back panel Try a different network cable Make sure you are using the correct and the current drivers See Server System References for a link to the current drivers 116 Intel Server System SR2500AL User s Guide Make sure the driver is loaded and the protocols are bound Make sure the hub port is configured for the same duplex mode as the network controller Make sure the correct networking software is installed Ifyou are directly connecting two servers without a hub you will need a crossover cable Check the network controller LEDs next to the NIC connectors Problems with Network The server hangs when the drivers are loaded Certain drivers may require interrupts that
90. d 10 Close both retention clips Note Make sure that all empty add in card slots have filler panels installed 11 Install the PCI riser assembly into the server system For instructions see Installing the PCI Riser Assembly 12 Install the processor air duct For instructions see Installing the Processor Air Duct 13 Install the server system cover For instructions see Installing the Server System Cover 14 Plug all peripheral devices and the AC power cable s into the server Removing a PCI Add in Card 1 64 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the processor air duct For instructions see Removing the Processor Air Duct Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Intel Server System SR2500AL User s Guide 9 Open the rear retention clip by pushing the blue slide upward and rotating clip to the fully open position see letter A Open the front retention clip by rotating 90 degrees outward see letter B Remove the PCI add in card from the riser card connector see letter C AF000327 Figure 56 Removing a Full Height Add In Card Close both retention clips
91. d by opening the retention mechanism see letter A in the figure below sliding the board through the fan assembly see letter B in the figure below and inserting it into the connector on the server board see letter C in the figure below Close the retention mechanism to hold the bridge board in place AF000163 Figure 64 Installing the Bridge Board into the Server System Intel Server System SR2500AL User s Guide 73 9 Install the server system cover For instructions see Installing the Server System Cover 10 Plug all peripheral devices and the AC power cable s into the server Replacing the Backplane The instructions below describe how to replace the backplane Removing the Backplane 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the mid plane board For instructions see Removing the Mid plane Board Note To prevent damage to your system you must ensure the mid plane is completely removed before attempting to remove the backplane 5 74 Remove all hot swap drive carriers regardless of whether a drive is installed in the carrier For instructions see Removing a SAS or SATA Hot swap Hard Disk Drive Disconnect all cables from t
92. d component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide board over any surface Other Hazards Battery Replacement Caution There is the danger of explosion if the battery is incorrectly replaced When replacing the battery use only the battery recommended by the equipment manufacturer Dispose of batteries according to local ordinances and regulations Do not attempt to recharge a battery Do not attempt to disassemble puncture or otherwise damage a battery Cooling and Airflow Caution Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with the chassis covers installed Operating the system without the covers in place can damage system parts To install the covers Check first to make sure you have not left loose tools or parts inside the system Check that cables add in boards and other components are properly installed Attach the covers to the chassis according to the product instructions Laser Peripherals or Devices Caution To avoid risk of radiation exposure and or personal injury Do not open the enclosure of any laser peripheral or device Laser peripherals or devices have are not user serviceable Return to manufacturer for servicing Intel Server System SR2500AL User s Guide 169 Deutsch Sicherheitshinweise f r den Server
93. d plane in your system install the power cable to the backplane and the sixth HDD board see letter A Install the short SATA cable to the backplane and the sixth HDD board see letter B Proceed to step 9 AF002122 Figure 48 Installing Power and SATA Cables Active Mid Plane Installed Note You will not use the long SATA cable from the 6th HDD kit in a system with an active mid plane Intel Server System SR2500AL User s Guide 55 56 If you have a passive mid plane installed in your system install the power cable to the backplane and the sixth HDD board see letter A Install one end of the long SATA cable labeled HSBP TAPE to the sixth HDD board see letter B and route the cable through the air baffle as shown see letter C Connect the other end of the cable labeled SERVER BOARD to the SATAS connector on the server board see letter D in the figure below Continue with step 9 AF002122 Figure 49 Installing Power and SATA Cables Passive Mid Plane Installed Note You will not use the short SATA cable from the 6th HDD kit in a system with a passive mid plane 10 11 12 Install a hard drive into the sixth hard drive bay For instructions see Installing a SAS or SATA Hot swap Hard Disk Drive Install the server system cover For instructions see Installing the Server System Cover Optional Install the front bezel For instructions see Installi
94. de composants d tach s l int rieur du syst me V rifiez que les c bles les cartes d extension et les autres composants sont correctement install s Fixez les panneaux au ch ssis en suivant les instructions du produit Intel Server System SR2500AL User s Guide P riph riques laser A Attention Pour viter tout risque d exposition aux rayonnements et ou de dommage personnel N ouvrez pas l enceinte d un p riph rique laser Les p riph riques laser ne sont pas r parables par l utilisateur Retournez les au fabricant en cas de probleme Espa ol Informaci n de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel las carcasas de servidor de Intel montaje en bastidor y en pedestal y los dispositivos perif ricos Para reducir el riesgo de da os corporales descargas el ctricas fuego y en el equipo lea este documento y preste atenci n a todos las advertencias y precauciones de esta gu a antes de instalar o mantener el producto de servidor de Intel En el caso de que haya diferencias entre la informaci n para un producto en particular contenida en este documento y la informaci n proporcionada con dicho producto o en el sitio Web la documentaci n del producto es la que prevalece S lo personal t cnico cualificado debe montar y prestar los servicios para el servidor Debe ce irse a las directrices de esta gu a y a las instrucciones de montaje de los ma
95. des surfaces soumis des temp ratures lev es Indique de ne pas toucher aux pales de ventilateur car cela peut entrainer des blessures Bep bI To Indique de d brancher tous les cordons d alimentation secteur pour d connecter l alimentation ES Veuillez r utiliser la batterie Domaines d utilisation pr vus Ce produit a t test comme quipement informatique ITE et peut tre install dans des bureaux des coles des salles informatiques et des endroits commerciaux similaires L utilisation du pr sent produit dans des cat gories et environnements de produits et domaines d application par exemple le domaine medical industriel r sidentiel les syst mes d alarme et les appareils de contr le autres qu ITE doit faire l objet d valuations suppl mentaires S lection d un emplacement 176 Le syst me est concu pour fonctionner dans un environnement standard de bureau Choisissez un emplacement respectant les conditions suivantes Propre sec et exempt de particules en suspension autres que la poussi re normale d une pi ce Bien ventil et l cart des sources de chaleur telles que la lumi re directe du soleil et les radiateurs l cart des sources de vibration ou des chocs physiques Isol amp des champs lectromagn tiques importants produits par des appareils lectriques Intel Server System SR2500AL User s Guide Dans les r gions suje
96. device selection OxD1 R R OFF A Trying boot device selection OxD2 R R G R Trying boot device selection OxD3 R R G A Trying boot device selection OxD4 R A OFF R Trying boot device selection OxD5 R A OFF A Trying boot device selection OxD6 R A G R Trying boot device selection OxD7 R A G A Trying boot device selection OxD8 A R OFF R Trying boot device selection OxD9 A R OFF A Trying boot device selection Intel Server System SR2500AL User s Guide Table 12 Diagnostic LED POST Code Decoder OXDA A R G R Trying boot device selection OxDB A R G A Trying boot device selection OxDC A A OFF R Trying boot device selection OxDE A A G R Trying boot device selection OxDF A A G A Trying boot device selection Pre EFI Initialization PEI Core OxEOh R R R OFF Started dispatching early initialization modules PEIM OxE2h R R A OFF Initial memory found configured and installed correctly OxE1h R R R G Reserved for initialization module use PEIM OxE3h R R A G Reserved for initialization module use PEIM Driver Execution Environment DXE Core OxE4h R A R OFF Entered EFI driver execution phase DXE OxE5h R A R G Started dispatching drivers OxE6h R A A OFF Started connecting drivers DXE Drivers OxE7h R A A G Waiting for user input OxE8h A R R OFF Checking password OxE9h A R R G Entering BIOS setup
97. e pr venir tout acc s non autoris l int rieur du syst me 5 Rebranchez tous les cordons d alimentation c a et c bles externes au syst me Le microprocesseur et le dissipateur de chaleur peuvent tre chauds si le systeme a t sous tension Faites galement attention aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Intel Server System SR2500AL User s Guide Danger d explosion si la batterie n est pas remont e correctement Remplacer uniquement avec une batterie du m me type ou d un type quivalent recommand par le fabricant Disposez des piles us es selon les instructions du fabricant Le systeme a t concu pour fonctionner dans un cadre de travail normal L emplacement choisi doit tre Propre et d pourvu de poussi re en suspension sauf la poussiere normale Bien a r et loin des sources de chaleur y compris du soleil direct e A l abri des chocs et des sources de vibrations e sol de forts champs lectromagn tiques g en r s par des appareils lectriques Dans les r gions sujettes aux orages magn tiques il est recomand de brancher votre syst me un supresseur de surtension et de d brancher toutes les lignes de t l communications de votre modem durant un orage Muni d une prise murale correctement mise la terre e Suffisamment spacieux pour vous permettre d acc der aux c
98. e Optical Drive or Internal USB Floppy eene 48 Removing a Slimline Optical Drive or Internal USB Floppy U U EUUEEUUEU UU 49 Installing a Tape Drive pcm 51 installing a Sixth Hard Drive en ere tie 54 Filing Empty Server System Bays use ea 57 Installing and Removing the PCI Riser Assembly EE keke 57 Removing the PCI Riser Assembly sessssssssesesseseeeeeenneee nennen nennen 57 Installing the PCI Riser Assembly EEE kk emen 59 Replacing a PCI Riser Card cm 60 Removing a PCI Riser Card iii 60 Installing a PCI Riser Card u eine 62 Installing and Removing a PCI Add in Card EE kk kk kk k kek 63 Installing a PCI Add in Card ensure 63 Removing a PCI Add in Card use 64 Installing the I O Expansion Module s E kk kk kk kk K k kk 66 Removing the I O Expansion Module S E kk kk kek k kek 67 Installing the Intel RMM and Intel RMM NIC ns 68 Removing the Intel RMM and Intel RMM NIC see 70 Replacing th Mid plane Board eere sn 71 Removing the Mid plane Board cccccceceeeeeeceeeeeeeeeeeeeeeeeeeeeeeesneeeaeeeeeeseeeneeseneeeees 71 Intel Server System SR2500AL User s Guide Installing the Mid plane Board nissan aa 72 Replacing the Backplane nennen DC 74 Removing the Backplane ans ae 74 installing the Backplane sin a a 76 Installing and Removing the RAID Activation Key and the RAID Mini D
99. e aeaaee ATE E ERa ee viii Intel Server System SR2500ALLX SR2500ALLXR Contents ees viii Intel Server System SR2500ALBRP SR2500ALBRPR Contents ss ix Chapter 1 Server System References ns 1 Chapter 2 Server System Features nn 3 Chassis Component Identification eco rein tad elsa 6 Internal Components estandar ce 6 Configuration JUMPETS u m o o ETT 9 A o ee 13 standard Control Panel sra ea aan 18 Intel Local Control Panel enr 19 A o 20 leg rgE qr 22 Hard Disk Drives t ON 22 Slimline Optical Drive Carrier ea 23 Advanced Management Options a nu ee 23 Intel Remote Management Module sss eee 23 Rack Maunted Sy Stem S454 xa kila salla l si s n an ii 23 Chapter 3 Hardware Installations and Upgrades 25 A 25 Tools and Supplies Need rtr tte an 25 System References una een 25 Removing and Installing from a Rack i kk kk kk KAK KAK KK KA KIR KA 25 Fixed Bracket Rack Mount Removal E iuE EEE kk kk kK AKA KK 25 Fixed Bracket Rack Mount Installation ooonoooccccccnnnnonnnncononcccncnonnnnnnnrn Ek 26 Basic Rail Back Mount Removal sir 27 Basic Rail Rack Mount Installation nenne nnnnnnnnnnnnnnnnn nenn e 27 Tool less Rail Rack Mount Servicing Ek kk kk kk kk k kk kK KH 28 Removing and Installing the Front Bezel
100. e letter A in the figure below Figure 87 Removing a Fan from the Fixed Fan Module Position the replacement fan so the connector on the fan is at the right and pointing down With the fan oriented correctly insert the fan into the fan module see letter A in the figure below and snap in place Intel Server System SR2500AL User s Guide 97 10 Figure 88 Installing a Fan into the Fixed Fan Module Install the fan module assembly For instructions see Replacing a Fan Module Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Installing and Removing the Rack Handles Installing the Rack Handles 1 98 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Align the rack handle with the two holes on the side of the server system as shown in the figure below Attach the rack handle to the server system with two screws as shown in the figure below Intel Server System SR2500AL User s Guide al wq E S Un Figure 89 Installing the Rack Handle AF000019 6 Install the server system cover For instructions see Installing the Server Syste
101. e letter A until it clicks into place see letter B AF000006 Figure 80 Installing Control Panel Module into the Server System 90 Intel Server System SR2500AL User s Guide 10 Install the server system cover For instructions see Installing the Server System Cover Optional Install the front bezel For instructions see Installing the Front Bezel Plug all peripheral devices and the AC power cable s into the server Replacing a Fan Module Replacing a Redundant Fan Module 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the processor air duct For instructions see Removing the Processor Air Duct Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Remove the optical drive cable if installed Remove the bridge board For instructions see Figure 61 Removing the Bridge Board from the Server System on page 71 37 Remove the large air baffle For instructions see Removing the Large Air Baffle Disconnect the fan cables from the mid plane Intel Server System SR2500AL User s Guide 91 10 Remove the fan module assembly by releasing the blue retention mechanism see letter A in the fi
102. e position covering pins 2 and 3 104 Intel Server System SR2500AL User s Guide E J UU BMC Force ma Update Mode m x o0 o O El Disable 9 2 en J Enable 3 Jll 310 gt J1D2 J1D1 o nO 0 2 Clear 30 CMOS c rm y O e a O O gt O TP02080 Figure 91 Clear Password Jumper Wait five seconds Return the Password Clear jumper to the Password Clear Protect position covering pins 1 and 2 Close the server chassis 7 Reconnect the AC power and power up the server 8 The password is now cleared and can be reset by going into BIOS setup Clearing the CMOS If you are not able to access the BIOS setup screens the CMOS Clear jumper will need to be used to reset the configuration RAM 1 Power down the system and disconnect the AC power 2 Open the server 3 Move the jumper from the normal operation position CMOS Clear by BMC at pins 1 and 2 to the CMOS Clear Force Erase position covering pins 2 and 3 Intel Server System SR2500AL User s Guide 1
103. e proper cooling You will need to remove the top cover to add or replace components inside of the server Before removing the chassis cover power down the server and unplug all peripheral devices and the AC power cable s Note A nonskid surface or a stop behind the server system may be needed to prevent the server system from sliding on your work surface 30 Intel Server System SR2500AL User s Guide A cm p qo Observe the safety and ESD precautions at the beginning of this book See Safety Information Turn off all peripheral devices connected to the server Turn off the server Disconnect the AC power cord s Remove the safety screw if it is installed See letter A in the figure below While holding in the blue button at the top of the server system in see letter B slide the top cover back until it stops see letter C Insert your finger in the notch see letter D and lift the cover upward to remove it TP02127 Figure 20 Removing the Server System Cover Installing the Server System Cover 1 Place the cover over the server system so that the side edges of the cover sit just inside the server system sidewalls Slide the cover forward until it clicks into place see letter A Optional Insert the safety screw at the center of the top cover see letter B 1f required Reconnect all peripheral devices and the AC power cord s Intel Server System SR2500AL User s Guide 31 TP
104. e telecomunicaciones al m dem durante una tormenta el ctrica Provista de una toma de corriente alterna correctamente conectada a tierra Provista de espacio suficiente para acceder a los cables de la fuente de alimentaci n ya que constituyen la desconexi n principal de la alimentaci n Intel Server System SR2500AL User s Guide Manipulaci n del equipo Reduzca el riesgo de da os personales o en el equipo e Respete los requisitos de sanidad y seguridad laborales de su pa s cuando traslade y levante el equipo Utilice medios mec nicos u otros que sean adecuados al trasladar o levantar el equipo e Para que el peso sea menor para manipularlo con m s facilidad extraiga los componentes que sean de f cil extracci n Advertencias de alimentaci n y el ctricas AA Precauci n El bot n de encendido indicado con la marca del modo de reposo o stand by NO DESCONECTA completamente la alimentaci n de CA del sistema ya que el modo de reposo de 5 V sigue activo mientras el sistema est enchufado Para desconectar el sistema debe desenchufar el cable de alimentaci n de CA de la toma de la pared Puede usar m s de un cable de alimentaci n de CA con el sistema Aseg rese de que todos los cables de alimentaci n de CA est n desenchufados Aseg rese de que los cables de alimentaci n de CA est n desenchufado antes de abrir la carcasa agregar o extraer cualquier componente que no es de conexi n en funcionamiento Algun
105. e und VorsichtsmaBnahmen nenn 170 Zielbenutzer der Anwendung irracionalidad share 171 siandortauswahl arista 171 Handhabung von Ger ten ua 171 Warnungen zu Netzspannung und Elektrizit t kk 172 Warnhinweise f r den Systemzugang nn 173 Warnhinweise f r Racks u e 173 Elektrostatische Entladungen ESD su 174 Andere Gefahren E D t ooo 0 174 gcc qe rr 175 Consignes de securite sur le serveur oooccccnoccccnononcconononnncnnnnnnncnnnnannn kk nn cnn kk Kek KA 175 S urit avertissements et mises en garde L Eke ken 175 Domaines d utilisation pr vus cn is 176 S lection d un emplacement iii 176 Pratiques de manipulation de l quipement uE Eke 177 Alimentation et avertissements en mati re d lectricit 177 Avertissements sur le cordon d alimentation ssse 178 Intel Server System SR2500AL User s Guide XV xvi Avertissements sur l acc s au systeme E sss 178 Avertissements sur le montage en rack nn 179 D charges lectrostatiques ESD 00oocconoccccnnccccccnonocnccccnnannnnnnnnnncnn cnn nc nn nn n e 180 Autres MISQUES qe 180 P riph riques laser mc P He 181 ESPA OL e E ER
106. eck the tested memory and chassis lists as well as the supported hardware and operating system list See Server System References for links to the tested component lists Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source 112 Intel Server System SR2500AL User s Guide Caution Turn off devices before disconnecting cables Before disconnecting any peripheral cables from the system turn off the system and any external peripheral devices Failure to do so can cause permanent damage to the system and or the peripheral devices 1 Turn off the system and all external peripheral devices Disconnect each device from the system except for the keyboard and the video monitor 2 Make sure the system power cord is plugged into a properly grounded AC outlet Make sure your video display monitor and keyboard are correctly connected to the system Turn on the video monitor Set its brightness and contrast controls to at least two thirds of their maximum ranges see the documentation supplied with your video display monitor 4 If the operating system normally loads from the hard disk drive make sure there is no CD ROM DVD disk in the optical drive 5 If the power LED does light attempt to boot from a USB floppy or from a CD ROM disk 6 Turn on the system Ifthe power LED does not light see Power Light Does Not Light Verifying Proper Opera
107. eens Starting Setup You can enter and start BIOS Setup under several conditions e When you turn on the server after POST completes the memory test When you have moved the CMOS jumper on the server board to the Clear CMOS position enabled In the two conditions listed above during the Power On Self Test POST you will see this prompt Press lt F2 gt to enter SETUP In a third condition when CMOS NVRAM has been corrupted you will see other prompts but not the lt F2 gt prompt Warning CMOS checksum invalid Warning CMOS time and date not set In this condition the BIOS will load default values for CMOS and attempt to boot If You Cannot Access Setup If you are not able to access BIOS Setup you might need to clear the CMOS memory For instructions on clearing the CMOS see Clearing the CMOS Setup Menus Each BIOS Setup menu page contains a number of features Except for those features that are provided only to display automatically configured information each feature is associated with a value field that contains user selectable parameters These parameters can be changed if the user has adequate security rights If a value cannot be changed for any reason the feature s value field is inaccessible Setup Menu Key Use describes the keyboard commands you can use in the BIOS Setup menus Table 4 Setup Menu Key Use Key to Press Description lt F1 gt Pressing lt F1 gt on any menu
108. emove the server s cover See the documentation that came with your server chassis for instructions on removing the server s cover Locate the DIMM sockets see Figure 25 Intel Server System SR2500AL User s Guide 35 36 10 DIMM B2 DIMM C1 Socket Socket DIMM B1 DIMM C2 Socket Socket DIMM A2 DIMM D1 Socket Socket DIMM A1 DIMM D2 Socket Socket Li Mn JE mi CM cum JEN CM m mo TP02072 Figure 25 Installing the Memory Make sure the clips at either end of the DIMM socket s are pushed outward to the open position see letter A in the figure above Holding the DIMM by the edges remove it from its anti static package Position the DIMM above the socket Align the notch on the bottom edge of the DIMM with the key in the DIMM socket The arrow in the inset in Figure 7 is pointing to the key in the socket see letter B in the figure above Inser
109. en the enhanced mode is selected you can choose to enable or disable AHCI Mode or Configure SATA as RAID Intel Embedded Server RAID Technology II is enabled by the option Configure SATA as RAID The Intel Embedded Server RAID Technology II feature provides RAID modes 0 1 and 10 For RAID 0 1 and 10 enclosure management is provided through the SATA_SGPIO connector on the server board when a cable is attached between this connector on the server board and to the backplane or C interface IFRAID 5 is desired the optional Intel RAID Activation Key AXXRAKSWS can be installed To enable RAID 5 this activation key is placed on the SATA Key connector that is located at the left side ofthe server board For information on how to install the Intel RAID Activation Key AXXRAKSWS accessory to enable RAID 5 see the documentation that is included with the accessory kit For information on configuring RAID see the RAID software user s guide that is included on the Intel Server Deployment Toolkit 2 0 CD Intel Server System SR2500AL User s Guide 13 SAS SATA Mid Planes The mid plane serves as the primary interface between the server board hot swap backplane and control panel Two midplanes are offered for this system a passive SATA data cables required and an active SAS SATA RAID no data cables required The following diagrams show the location for each connector found on the mid planes AF000047
110. epresentative or authorized dealer for help Power Light Does Not Light Check the following Did you press the power on button Is the system operating normally If so the power LED might be defective or the connection from the control panel to the server board might be loose Have you securely plugged the server AC power cord into the power supply Some ATX power supplies have a power switch on the back of the power supply next to the fan If your system has one is it turned on Remove all add in cards and see if the system boots If successful add the cards back in one at a time with a reboot between each addition Make sure the memory DIMMs comply with the system requirements Make sure the memory DIMMs have been populated according to the system requirements Remove the memory DIMMs and re seat them Make sure the processor s comply with the system requirements Make sure the processor s have been populated according to the system requirements Remove the processor s and re seat them Make sure the chassis standoffs are installed only below mounting holes Misplaced standoffs can contact the pins on the bottom of the server board and cause a short No Characters Appear on Screen 114 Check the following Is the keyboard functioning Test 1t by turning the Num Lock function on and off to make sure the Num Lock light is functioning Is the video monitor plugged in and turned on If you are using a switch
111. er Board Install the PCI riser assembly into the server system For instructions see Installing the PCI Riser Assembly Install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide Removing the 1 0 Expansion Module s 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Remove the I O expansion module s from the server board see letter A in the figure below Remove the standoffs from the server board see letter B in the figure below Install the I O expansion module cover s into the system back panel see letter C in the figure below AF000743 Figure 58 Removing the I O Expansion Module s from the Server Board 10 11 Install the PCI riser assembly into the server system For instructions see Installing the PCI Riser Assembly Install the processor air duct For instructions see Installing the Processor Air Duct
112. er system with the small air baffle in place The small air baffle 1s required for proper airflow within the server system 40 Intel Server System SR2500AL User s Guide Removing the Small Air Baffle 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the server system cover For instructions see Removing the System Cover 4 Pull up and out on the air baffle to remove it See the figure below TP02136 Figure 30 Removing the Small Air Baffle Installing the Small Air Baffle 1 Lower the baffle into the server system 2 Snap the baffle into place as shown in the figure below Intel Server System SR2500AL User s Guide 41 TP02137 Figure 31 Installing the Small Air Baffle 3 Install the server system cover For instructions see Installing the Server System Cover 4 Plug all peripheral devices and the AC power cable s into the server Removing and Installing the Large Air Baffle Some installation processes will require that you remove the large air baffle that is placed behind the hard drive bays next to the fan module near the front of your server The steps below describe how to remove and then install the large air baffle Use these steps only when it is indicated as necessary for a component insta
113. es not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non operating limits Intel Intel Pentium and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright O 2006 2007 Intel Corporation All Rights Reserved ii Intel Server System SR2500AL User s Guide Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions See also Intel Server Boards and Server Chassis Safety Information on the Intel Deployment Assistant CD and or at http support intel com support motherboards server sb cs 010770 htm Wichtige Sicherheitshinweise Lesen Sie zun chst s mtliche Warnund Sicherheitshinweise in diesem Dokument bevor Sie eine der Anweisungen ausf hren Beachten Sie hierzu auch die Sicherheitshinweise zu Intel Serverplatinen und Servergeh usen auf der Intel Deployment Assistant CD oder unter http support intel com support motherboards server sb cs 010770 htm Consignes de securite
114. ety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the large air baffle For instructions see Removing the Large Air Baffle Remove the fan module assembly For instructions see Replacing a Fan Module Disconnect all power cables from the server board backplane and mid plane Remove the hot swap power supply supplies For instructions see Replacing the Power Supply Remove the two screws to release the module see letter A Lift the module from the server system see letter B AF000146 Figure 78 Removing the Power Distribution Module 10 Set the replacement power supply distribution module into the server system and screw the module into place 11 Install the hot swap power supply supplies For instructions see Replacing the 88 Power Supply Intel Server System SR2500AL User s Guide 12 Connect all power cables to the server board 13 Install the fan module assembly For instructions see Replacing a Fan Module 14 Install the large air baffle For instructions see Installing the Large Air Baffle 15 Install the server system cover For instructions see Installing the Server System Cover 16 Plug all peripheral devices and the AC power
115. f the screen at http support intel com support motherboards server chassis SR2500 Accessories or other Intel server products Hardware peripheral boards adapter cards and operating systems that have been tested with this product Spares and Configuration Guide Found available from your Intel field representative or on the Server Configurator Tool at http indigo intel com serverconfiguratortool default aspx Tested HardwareOperating Systems List Found at http support intel com support motherboards server S5000PAL To make sure your system falls within the allowed power budget Power Budget Tool Found at http support intel com support motherboards server S5000PAL For software to manage your Intel server Intel System Management Software Found at http support intel com support motherboards server sysmgmt index htm For diagnostics test software Diagnostics Found at http support intel com support motherboards server S5000PAL Intel Server System SR2500AL User s Guide Server System Features This chapter briefly describes the main features of the server system This chapter provides illustrations of the product a list of the server system features and diagrams showing the location of important components and connections on the server system AF000027 Figure 1 Intel Integrated Server System SR2500AL Table 2 summarizes the features of the server system
116. file to a temporary folder on your hard drive See Server System References for a link to the update software Note Review the instructions and release notes that are provided in the readme file distributed with the BIOS image file before attempting a BIOS upgrade The release notes contain critical information regarding jumper settings specific fixes or other information to complete the upgrade Upgrading the BIOS Follow the instructions in the readme file that came with the BIOS upgrade When the update completes remove the bootable media from which you performed the upgrade Caution Do not power down the system during the BIOS update process The system will reset automatically when the BIOS update process is completed Note You may encounter a CMOS Checksum error or other problem after reboot If this happens shut down the system and boot it again CMOS checksum errors require that you enter Setup check your settings save your settings and exit Setup Clearing the Password If the user or administrator password s is lost or forgotten moving the password clear jumper into the clear position clears both passwords The password clear jumper must be restored to its original position before a new password s can be set 1 Power down the system and disconnect the AC power 2 Open the server chassis 3 Move the jumper from the normal operation position Password Clear Protect at pins 1 and 2 to the Password Clear Eras
117. gure below sliding the assembly to the left see letter B and lifting the assembly off of the standoff and out of the system see letter C Figure 81 Removing the Redundant Fan Module 11 Install the replacement fan module assembly by lowering it over the standoff see letter A in the figure below and sliding the assembly to the right see letter B Figure 82 Installing the Redundant Fan Module 12 Connect the fan cables to the mid plane 13 Install the large air baffle For instructions see Installing the Large Air Baffle Re route cables through the air baffle as necessary 92 Intel Server System SR2500AL User s Guide 14 15 16 17 18 19 Install the bridge board For instructions see Figure 64 Installing the Bridge Board into the Server System on page 73 Install the optical drive cable optional Install the PCI riser assembly For instructions see Installing the PCI Riser Assembly Install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Replacing a Fixed Fan Module 1 Intel Server System Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server a
118. h use an indem Sie die zuvor gel sten Schrauben wieder anbringen Ziehen Sie diese gut an 4 Bringen Sie die Verschlu einrichtung Padlock wieder an und schlie en Sie diese um ein unerlaubtes Offnen des Systems zu verhindern 5 Schlie en Sie alle externen Kabel und den AC Stromanschlu stecker Ihres Systems wieder an Der Mikroprozessor und der K hler sind m glicherweise erhitzt wenn das System in Betrieb ist Au erdem k nnen einige Platinen und Geh useteile scharfe Spitzen und Kanten aufweisen Arbeiten an Platinen und Geh use sollten vorsichtig ausgef hrt werden Sie sollten Schutzhandschuhe tragen Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr Die Batterie darf nur durch denselben oder einen entsprechenden vom Hersteller empfohlenen Batterietyp ersetzt werden Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend 156 Intel Server System SR2500AL User s Guide Das System wurde f r den Betrieb in einer normalen B roumgebung entwickelt Der Standort sollte sauber und staubfrei sein Hausstaub ausgenommen gut gel ftet und keinen Heizquellen ausgesetzt sein einschlieBlich direkter Sonneneinstrahlung keinen Ersch tterungen ausgesetzt sein keine starken von elektrischen Ger ten erzeugten elektromagnetischen Felder aufweisen in Regionen in denen elektrische St rme auftreten mit einem Uberspannungsschutzger
119. he backplane Firmly grasp the top of the backplane and remove the backplane from the server system by pulling straight up as shown in the figure below Intel Server System SR2500AL User s Guide AF000016 Figure 65 Removing the Backplane from the Server System Intel Server System SR2500AL User s Guide 75 Installing the Backplane 1 2 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the mid plane board For instructions see Removing the Mid plane Board Remove all hot swap drive carriers regardless of whether a drive is installed in the carrier For instructions see Removing a SAS or SATA Hot swap Hard Disk Drive Hold the backplane only by the edges Do not push or pull on any components on the backplane set the backplane in place at the front of the server system with the sides of the board resting in the guides at the left and right sides of the server system Slide the backplane into the server system guides at the left and right sides of the server system until the pins at the left and right sides of the backplane bracket are fully inserted into the matching holes in the server system see letters A and B 8 9 76 Soe
120. he standoffs from the server board see letter C in the figure below Install the Intel RMM NIC module cover into the system back panel see letter D in the figure below AF000744 Figure 60 Removing the Intel RMM and the Intel RMM NIC Module from 10 11 12 the Server System Install the PCI riser assembly into the server system For instructions see Installing the PCI Riser Assembly Install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide Replacing the Mid plane Board The instructions below describe how to replace the mid plane board Removing the Mid plane Board 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the server system cover For instructions see Removing the System Cover 4 Disconnect all cables from the mid plane board Remove the bridge board by lifting the retention mechanism from the mid plane and the server board see letter A in the figure below and lifting straight up see letter B in the figure below and sliding the board ou
121. heral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover If a filler panel is installed press the release lever see letter A and use the finger hole see letter B to remove the filler panel as shown in the figure below AF000021 Figure 74 Removing Power Supply Filler Panel from the Server System 5 86 If a power supply is installed release the latch see letter A and remove the power supply by pulling on the handle see letter B as shown in the figure below Intel Server System SR2500AL User s Guide AF000022 Figure 75 Removing Power Supply Module from the Server System 6 Insert the replacement power supply module into the power supply cage until it clicks into place AF000024 Figure 76 Installing Power Supply Module into the Server System 7 If no power supply is to be installed insert a power supply filler panel as shown in the figure below AF000023 Figure 77 Installing Power Supply Filler Panel into the Server System 8 Install the server system cover For instructions see Installing the Server System Cover 9 Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide 87 Replacing the Power Distribution Module To replace the power distribution module use the following instructions 1 N ey cpm 9o ul Observe the saf
122. icable taxes Intel reserves the right to change the pricing for telephone support at any time without notice Before calling fill out an Intel Server Issue Report Form A sample form is provided on the following pages However for the fastest service please submit your form via the Internet For an updated support contact list see http www intel com support 9089 htm U S and Canada 916 377 7000 Europe Belgium 02 714 3182 Denmark 38 487077 Finland 9 693 79297 France 01 41 918529 Germany 069 9509 6099 Holland 020 487 4562 Italy 02 696 33276 Norway 23 1620 50 Spain 91 377 8166 Sweden 08 445 1251 UK 870 6072439 In Asia Pacific region Japan Australia 1800 649931 Cambodia 63 2 636 9797 via Philippines China 800 820 1100 toll free ici 8 621 33104691 not toll free Hong Kong 852 2 844 4456 India 0006517 2 68303634 manual toll free You need an IDD equipped telephone Indonesia 803 65 7249 Korea 822 767 2595 Malaysia 1 800 80 1390 Myanmar 63 2 636 9796 via Philippines New Zealand 0800 444 365 Pakistan 632 63684 15 IDD via Philippines Philippines 1 800 1 651 0117 Singapore 65 6213 1311 Taiwan 2 2545 1640 Thailand 1 800 631 0003 Vietnam 632 6368416 IDD via Philippines Domestic 0120 868686 Outside country 81298 47 0800 Latin Americ
123. indlich gegen ber elektrostatischer Entladung sein Halten Sie Platinen nur an den Kanten fest Legen Sie die Platinen nach dem Auspacken aus der Schutzh lle oder nach dem Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete statisch entladene Unterlage Verwenden Sie dazu sofern verf gbar eine leitf hige Schaumstoffunterlage aber nicht die Schutzh lle der Platine Ziehen Sie die Platine nicht ber eine Fl che Andere Gefahren Batterieaustausch Caution Wird die Batterie unsachgem ausgetauscht besteht Explosionsgefahr Verwenden Sie als Ersatz nur die vom Ger tehersteller empfohlene Batterie Beachten Sie bei der Entsorgung von Batterien die g ltigen Bestimmungen Versuchen Sie nicht eine Batterie aufzuladen Versuchen Sie nicht eine Batterie zu ffnen oder sonstwie zu besch digen K hlung und Luftstrom 174 Caution Verlegen Sie Kabel sorgf ltig entsprechend der Anleitung um St rungen des Luftstroms und K hlungsprobleme zu vermeiden Zur Gew hrleistung des ordnungsgem en K hlungs und Luftstromverhaltens darf das System nur mit angebrachten Geh useabdeckungen betrieben werden Die Inbetriebnahme des Systems ohne Abdeckung kann zur Besch digung von Systemkomponenten f hren So bringen Sie die Abdeckung wieder an e Vergewissern Sie sich zun chst da Sie keine Werkzeuge oder Teile im Geh use vergessen haben Intel Server System SR2500AL User s Guide Pr fen Sie ob
124. invokes the general help window Left and right arrows The left and right arrow keys are used to move between the major menu pages The keys have no affect if a submenu or pick list is displayed Up arrow Select Item up The up arrow is used to select the previous value in a menu item s option list or a value field pick list Pressing the lt Enter gt key activates the selected item Down arrow Select Item down The down arrow is used to select the next value in a menu item s option list or a value field pick list Pressing the lt Enter gt key activates the selected item lt F5 gt or lt gt Change Value The minus key or the lt F5 gt function key is used to change the value of the current item to the previous value This key scrolls through the values in the associated pick list without displaying the full list lt F6 gt or lt gt Change Value The plus key or the lt F6 gt function key is used to change the value of the current menu item to the next value This key scrolls through the values in the associated pick list without displaying the full list On 106 key Japanese keyboards the plus key has a different scan code than the plus key on the other keyboard but it has the same effect lt Enter gt Execute Command The lt Enter gt key is used to activate submenus when the selected feature is a submenu or to display a pick list if a selected feature has a value field or to selec
125. ion Found at http support intel com support motherboards server S5000PAL For basic BIOS settings and chipset information Intel 5000 Series Chipsets Server Board Family Datasheet Found at http support intel com support motherboards server S5000PAL For in depth BIOS information Inte S5000 Server Board Family Server BIOS External Product Specification Found available to order by contacting your Intel field representative Intel reference number 19953 For in depth firmware information on the Baseboard Management Controller BMC ESB2 Baseboard Management Controller Core External Product Specification for the Intel S5000 Server Board Family Found available to order by contacting your Intel field representative Intel reference number 19692 For in depth information on Intel I O Acceleration Technology Inte 1 0 Acceleration Technology Improves Intel Server Platform Network Performance Reliability and Efficiency whitepaper Found available from your Intel field representative Table 1 Server System References For this information or software Use this Document or Software If you just received this product and need to install it Intel Integrated Server System SR2500AL Quick Start User s Guide Found in the product box For virtual system tours and interactive repair information A link to the SMaRT Tool is available under Other Resources at the right side o
126. kk kek 115 System Cooling Fans Do Not Rotate Properly EEEE eke 115 Drive Activity Light Does Not Light sea aa 116 CD ROM Drive or DVD ROM Drive Activity Light Does Not Light 116 Cannot Connect to a Server 116 Problems with Network RUE E TT 117 System Boots when Installing PCI Card E Ek kk kek 118 Problems with Newly Installed Application Software oooooccccnnnccccinnnccccccnccnccnnnnnnncnnns 118 Problems with Application Software that Ran Correctly Earlier 118 Devices are not Recognized under Device Manager Microsoft Windows Operating o ee ee ee 119 Hard Drive s are not Recognized u a en 119 Bootable CD ROM Disk Is Not Detected iuEE kk kk eks 119 LED eg cule EE n a n ica 120 BIOS POST Beep Codes oni ioni A oa sisi 120 Appendix C Intel Server Issue Report Form sico ee 123 Appendix D LED Decoder c cocina 127 Appendix E Getting Heli aida 133 World Wide Web auch 133 AP te ehe 133 Appendix F Regulatory and Compliance Information 137 Product Regulatory Compliance sise 137 Product Safety Compliance si 137 Product Regulatory Compliance References ococcccooccccccconcccnonoccnnncnnnnncncnnnnccnnnnnnccnnns 138 Electromagnetic Compatibility Notices E LEEEE kk kk k Kek ke 141 FCC Verification Statement USA EEE kk enne 141 Industry Canada ICES 0
127. known as errata Current characterized errata are available upon request This Limited Warranty does not cover damages due to external causes including accident problems with electrical power usage not in accordance with product instructions misuse neglect alteration repair improper installation or improper testing Warranty Limitations and Exclusions These warranties replace all other warranties expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Intel makes no expressed warranties beyond those stated here Intel disclaims all other warranties expressed or implied including without limitation implied warranties of merchantability and fitness for a particular purpose Some jurisdictions do not allow the exclusion of implied warranties so this limitation may not apply All expressed and implied warranties are limited in duration to the limited warranty period No warranties apply after that period Some jurisdictions do not allow limitations on how long an implied warranty lasts so this limitation may not apply to you Limitations of Liability Intel s responsibility under this or any other warranty implied or expressed is limited to repair replacement or refund as set forth above These remedies are the sole and exclusive remedies for any breach of warranty Intel is not responsible for direct special incidental or consequential damages resul
128. l the processor air duct For instructions see Installing the Processor Air Duct 6 Install the server system cover For instructions see Installing the Server System Cover 7 Optional Install the front bezel For instructions see Installing the Front Bezel 8 Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide 59 Replacing a PCI Riser Card Caution PCI riser connectors are NOT hot swappable Before removing or replacing the riser connector you must first take the server out of service turn off all peripheral devices connected to the system turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet Note To eliminate the possibility of installing the replacement connector on the wrong side of the PCI riser assembly replace one connector at a time Removing a PCI Riser Card 1 60 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the processor air duct For instructions see Removing the Processor Air Duct Disconnect any cables attached to any add in cards Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly
129. ladores Si el sistema se le ha suministrado con una protecci n para el ventilador aseg rese de que cuando est funcionando el sistema la protecci n est en su sitio Advertencias sobre el montaje en bastidor El bastidor del equipo se debe sujetar con un soporte fijo para evitar que se caiga cuando se extraiga un servidor o una pieza del mismo El bastidor del equipo debe instalarse siguiendo las instrucciones del fabricante del bastidor Instale el equipo en el bastidor comenzando desde la parte de abajo con el equipo m s pesado en la parte inferior del bastidor Extraiga las piezas del equipo del bastidor de una a una El usuario es el responsable de la instalaci n de un dispositivo de desconexi n de la alimentaci n principal para toda la unidad del bastidor El acceso a este dispositivo de desconexi n deber ser de f cil acceso y deber n incluirse indicaciones que lo identifiquen como el control de alimentaci n el ctrica de toda la unidad no s lo de los servidores Para evitar el riesgo de descargas el ctricas deber instalar una conexi n a tierra apropiada para el bastidor y para cada pieza del equipo instalada en el mismo Descarga electrost tica ESD A Precauci n Las descargas electrost ticas pueden da ar las unidades de disco las tarjetas y otros componentes Recomendamos que realice todos los procedimientos en una estaci n de trabajo protegida contra descargas electrost ticas En caso de que no hay
130. llation process Always operate your server system with the large air baffle in place The large air baffle is required for proper airflow within the server system Removing the Large Air Baffle 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the server system cover For instructions see Removing the System Cover 4 Note how the cables are routed over and under the air baffle if any You will need to re route these cables 42 Intel Server System SR2500AL User s Guide 5 Pull up on the air baffle to remove it See the figure below You may need to remove or hold cables out of the way TP02134 Figure 32 Removing the Large Air Baffle Installing the Large Air Baffle 1 Lower the baffle into the server system and snap into the server board standoff as shown in the figure below 2 While setting the baffle into place route the cables beneath it appropriately See Appendix Cable Routing or the Quick Reference Label that came with your system for help in determining where the cables should be routed Intel Server System SR2500AL User s Guide 43 TP02134 Figure 33 Installing the Large Air Baffle 3 Install the server system cover For instructions see Installing the Server System Cover 4 Plug all peripheral devices and the AC power c
131. ly Output Capability Voltage Maximum Current 3 3 V 36 A 5 0 V 45 A 5 V Standby 12 0 20A 120V 20A Warning Do not exceed a combined power output of 90 Watts for the 5 V and 3 3 V outputs Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supplies to overheat and malfunction Intel Server System SR2500AL User s Guide 109 System Environmental Specifications Table 6 System Environmental Specifications Temperature Non operating 40 to 70 C Operating 10 to 35 C derated 0 5 C for every 1000 ft 305 m to a maximum of 10 000 ft Humidity Non operating 90 relative humidity non condensing at 30 C Shock Operating 2 0 g 11 msec 1 2 sine Packaged Operational after an 18 free fall Acoustic noise 7 Bels in sound power for a typical office ambient temperature 65 75 F Your selection of peripherals may change the noise level Electrostatic Tested to 15 kilovolts kV no component damage discharge ESD 110 Intel Server System SR2500AL User s Guide Appendix B Troubleshooting This chapter helps you identify and solve problems that might occur while you are using the system For any issue first ensure you are using the latest firmware and files Firmware upgrades include updates for BIOS the Baseboard Management Controller BMC and the hot swap controller HSC See Server System References for a link t
132. ly damaged 7 Lineup the alignment marks on the processor and the socket and insert the processor into the socket Note Make sure the alignment triangle mark and the alignment triangle cutout align correctly 8 Remove the protective socket cover see Figure 28 Note Retain the protective socket cover for use when removing a processor that will not be replaced 38 Intel Server System SR2500AL User s Guide TP02076 Figure 28 Removing the Socket Cover 9 Lower the CPU load plate and lower the socket lever completely Installing the Heat Sink s The heat sink has Thermal Interface Material TIM located on the bottom of it Use caution when you unpack the heat sink so you do not damage the TIM 1 Set the heat sink over the processor lining up the four captive screws with the four posts surrounding the processor 2 Loosely screw in the captive screws on the heat sink corners in a diagonal manner Do no fully tighten one screw before tightening another 3 Gradually and equally tighten each captive screw until each is firmly tightened TP02077 Figure 29 Installing the Heat Sink 2U Passive Heat Sink Shown Intel Server System SR2500AL User s Guide 39 4 Reinstall and reconnect any parts you removed or disconnected to reach the processor sockets 5 Replace the server s cover and reconnect the AC power cord s See the documentation that came with your server chassis for instructio
133. m Cover 7 Install the front bezel For instructions see Installing the Front Bezel 8 Plug all peripheral devices and the AC power cable s into the server Removing the Rack Handles 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the front bezel if it is installed For instructions see Removing the Front Bezel 4 Remove the server system cover For instructions see Removing the System Cover 5 Remove the two screws holding the rack handle in place and remove the rack handle from the server system as shown in the figure below Intel Server System SR2500AL User s Guide 99 ol Figure 90 Removing the Rack Handle AF000020 6 Install the server system cover For instructions see Installing the Server System Cover 7 Plug all peripheral devices and the AC power cable s into the server 100 Intel Server System SR2500AL User s Guide 4 Server Utilities Using the BIOS Setup Utility This section describes the BIOS Setup Utility options which is used to change server configuration defaults You can run BIOS Setup with or without an operating system being present See Server System References for a link to the Intel 5000 Series Chipsets Server Board Family Datasheet where you will find details about specific BIOS setup scr
134. m SR2500AL User s Guide Chassis Component Identification This section helps you identify the components of your server system If you are near the system you can also use the Quick Reference Label provided on the inside of the chassis cover to assist in identifying components Internal Components AF000028 Rack Handles l Processor Air Duct B SAS SATA Backplane J System Fan Assembly redundant option shown C Air Baffles K Bridge Board D Power Distribution Module L Control Panel standard control panel shown E Power Supply Module Housing supports M Flex Bay 6th HDD or Tape Drive optional up to two power supply modules F Riser Card Assembly N Hard Drive Bays Integrated Chassis Intrusion Switch O Slimline Optical Drive Bay H System Memory below duct in illustration Figure 2 ChassisComponents 6 Intel Server System SR2500AL User s Guide Server Board Connector and Component Locations 2 o o K
135. n den Server angeschlossene Telekommunikationssysteme Netzwerke und Modems Hinweis f r Netzkabel Wenn kein Netzkabel mit dem Produkt geliefert wurde kaufen Sie ein Kabel das f r die Caution Pr fen Sie zur Vermeidung von Stromschlag oder Feuergefahr die mit dem Produkt zu verwendenden Netzkabel wie folgt Nehmen Sie keine nderungen an einem Netzkabel vor und benutzen sie es nicht wenn es nicht genau in die geerdeten Netzsteckdosen pa t e Netzkabel m ssen die folgenden Anforderungen erf llen Die Nennbelastbarkeit des Netzkabels mu mindestens so hoch sein wie die am Produkt angegebenen Nennstromaufnahme Das Netzkabel mu einen zur Netzsteckdose passenden Schutzkontakt besitzen Die Netzkabel sind die Hauptvorrichtung zum Trennen des Ger ts vom Stromnetz Die Steckdose mu in der N he der Anlage angebracht und gut erreichbar sein e Netzkabel m ssen an eine ordnungsgem geerdete Steckdose angeschlossen sein 172 Intel Server System SR2500AL User s Guide Warnhinweise f r den Systemzugang Caution Caution Caution Um Verletzungen und Besch digungen zu vermeiden sollten Sie vor Arbeiten im Produktinneren folgende Sicherheitsanweisungen beachten Schalten Sie alle am Produkt angeschlossenen Peripherieger te aus Schalten Sie das System mit dem Netzschalter aus Trennen Sie das Ger t von der Stromquelle indem Sie alle Netzkabel vom System bzw aus der Steckdose ziehen
136. n for help Any changes or modifications not expressly approved by the grantee of this device could vold the user s authority to operate the equipment The customer is responsible for ensuring compliance of the modified product Only peripherals computer input output devices terminals printers etc that comply with FCC Class A or B limits may be attached to this computer product Operation with noncompliant peripherals is likely to result in interference to radio and TV reception All cables used to connect to peripherals must be shielded and grounded Operation with cables connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception Intel Server System SR2500AL User s Guide 141 Industry Canada ICES 003 Cet appareil num rique respecte les limites bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Apparelis Num riques NMB 003 dictee par le Ministre Canadian des Communications English translation of the notice above This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Europe CE Declaration of Conformity This product has been tested in accordance to and complies with the Low Voltage Directive
137. n und befolgen In dem vorliegenden Handbuch sowie auf dem Produkt und auf der Verpackung werden folgende Sicherheitssymbole verwendet VORSICHT Weist auf eine Gefahrenquelle hin die bei Nichtbeachtung des VORSICHTSHINWEISES zu leichteren Verletzungen bzw Sachbesch digungen f hren kann WARNUNG Weist auf eine Gefahrenquelle hin die bei Nichtbeachtung der WARNUNG zu ernsten Verletzungen f hren kann A Weist auf potentielle Gefahr bei Nichtbeachtung der angezeigten Informationen hin A Weist auf die Gefahr eines Stromschlags hin der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder t dlichen Verletzungen f hren kann A Weist auf Verbrennungsgefahr an hei en Bauteilen bzw Oberfl chen hin Intel Server System SR2500AL User s Guide amp Weist darauf hin da das Anfassen des Geblases zu Verletzungen f hren kann Sata Bedeutet alle Netzkabel abzuziehen und das Ger t von der Netzspannung Buna dkan zu trennen Cra Bereiten Sie bitte Batterie auf UJ Zielbenutzer der Anwendung Dieses Produkt wurde in seiner Eigenschaft als IT Ger t getestet das in B ros Schulen Computerr umen und hnlichen ffentlichen R umlichkeiten installiert werden kann Die Eignung dieses Produkts f r andere Einsatzbereiche als IT z B Medizin Industrie Alarmsysteme oder Pr fger te kann u U weitere Tests erfordern Standortauswahl Das System ist f r den Betrieb innerhalb normaler B
138. nd unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the processor air duct For instructions see Removing the Processor Air Duct Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Remove the optical drive cable if installed Remove the bridge board For instructions see Figure 61 Removing the Bridge Board from the Server System on page 71 Remove the large air baffle For instructions see Removing the Large Air Baffle Disconnect the fan cables from the mid plane SR2500AL User s Guide 93 10 Remove the fan module assembly by pulling the blue retention mechanism towards the middle fan see letter A in the figure below and sliding the assembly to the left see letter B in and lifting the assembly off of the standoff and out of the system see letter C Figure 83 Removing the Fixed Fan Module 11 Install the replacement fan module assembly by lowering it over the standoff see letter A in the figure below and sliding the assembly to the right see letter B Figure 84 Installing the Fixed Fan Module 94 Intel Server System SR2500AL User s Guide 12 13 14 15 16 17 18 19 Connect the fan cables to the mid plane Install the large air baffle For instructions see Installing the La
139. ndicates shock hazards that result in serious injury or death if safety instructions are not followed A Indicates hot components or surfaces Intel Server System SR2500AL User s Guide 165 gt Indicates do not touch fan blades may result in injury atra Indicates to unplug all AC power cord s to disconnect AC power n cn Please recycle battery Us Intended Application Uses This product was evaluated as Information Technology Equipment ITE which may be installed in offices schools computer rooms and similar commercial type locations The suitability of this product for other product categories and environments such as medical industrial residential alarm systems and test equipment other than an ITE application may require further evaluation Site Selection The system is designed to operate in a typical office environment Choose a site that is Clean dry and free of airborne particles other than normal room dust Well ventilated and away from sources of heat including direct sunlight and radiators Away from sources of vibration or physical shock Isolated from strong electromagnetic fields produced by electrical devices In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppresser and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with
140. neas de telecomunicaci n que est n conectados al sistema Guarde todos los tornillos o elementos de fijaci n cuando retire las cubiertas de acceso Cuando termine de operar en el interior del producto vuelva a colocar los tornillos o los elementos de fijaci n originales de la cubierta de acceso No acceda al interior de la fuente de alimentaci n No hay elementos en la fuente de alimentaci n que usted pueda reparar y utilizar Devu lvala al fabricante para repararla Apague el servidor y desconecte todos los cables de alimentaci n antes de agregar o reemplazar cualquier componente que no es de conexi n en funcionamiento Intel Server System SR2500AL User s Guide ZI reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de la fuente de alimentaci n que va a reemplazar antes de extraerla del servidor AA Precauci n Si el servidor se ha estado ejecutando los procesadores y disipadores de calor estar n recalentados A no ser que est instalando o extrayendo un componente de conexi n en funcionamiento deje que el sistema se enfr e antes de abrir las cubiertas Para que no llegue a tocar los componentes que est n calientes cuando est realizando una instalaci n de conexi n en funcionamiento tenga cuidado al extraer o instalar los componentes de conexi n en funcionamiento ASD Precauci n Para evitar posibles da os no toque las aspas en movimiento de los venti
141. ng modem telecommunication circuitry must be UL listed In addition the modem must have the appropriate telecommunications safety and EMC approvals for the region in which it is sold Peripheral Storage Devices must be a UL recognized or UL listed accessory and TUV or VDE licensed Total server configuration is not to exceed the maximum loading conditions of the power supply Intel Server System SR2500AL User s Guide 147 End of Life Product Recycling Product recycling and end of life take back systems and requirements vary by country Contact the retailer or distributor of this product for information about product recycling and or take back 148 Intel Server System SR2500AL User s Guide Appendix G Warranty Limited Warranty for Intel Chassis Subassembly Products Intel warrants that the Products defined herein as the Intel chassis subassembly and all of its various components and software delivered with or as part of the Products to be delivered hereunder if properly used and installed will be free from defects in material and workmanship and will substantially conform to Intel s publicly available specifications for a period of three 3 years after the date the Product was purchased from an Intel authorized distributor Software of any kind delivered with or as part of products is expressly provided as is unless specifically provided for otherwise in any software license accompanying the software If any Prod
142. ng the Front Bezel Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide Filling Empty Server System Bays A filler panel drive blank or empty drive carrier must be installed into an empty drive bay To access the drive bays remove the front bezel if it is installed For instructions see Removing the Front Bezel With the bezel removed install the appropriate panel s blank or empty hard drive bay s as described below If you do not have an optical drive installed in the slimline bay install the slimline filler panel See letter A in the figure below If you do not have a tape drive installed install a filler panel into the empty slot above the sixth drive bay See letter B in the figure below If you do not have a sixth drive or a tape drive installed install the drive bay blank into the sixth drive bay See letter C in the figure below Install empty hard drive carriers into any remaining empty hard drive bays AF000011 Figure 50 Installing the Filler Panels Installing and Removing the PCI Riser Assembly Removing the PCI Riser Assembly To remove the PCI riser assembly use the following instructions 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Intel Server System SR2500AL U
143. ning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the front bezel if it is installed For instructions see Removing the Front Bezel Intel Server System SR2500AL User s Guide 51 4 Remove the server system cover For instructions see Removing the System Cover 5 Remove the tape drive filler panel from the server system by using a long screwdriver to push it out from the inside of the server system See the figure below to locate the tape drive filler panel AF000036 Figure 43 Removing Tape Drive Filler Panel from the Server System 6 Remove the hard drive blank that is installed in the sixth drive bay See the figure below to locate the sixth drive filler panel AF000035 Figure 44 Removing Sixth Drive Filler Panel from the Server System Intel Server System SR2500AL User s Guide 52 7 Attach the tape drive to the tape drive carrier kit using the four screws that were included with the tape drive kit See the figure below AF000032 Figure 45 Inserting a Tape Drive into the Carrier 8 Slide the tape drive carrier with the installed tape drive into the combined tape drive bay sixth drive bay until the carrier clicks into place AF000033 Figure 46 Installing Tape Drive Assembly into the Server System Intel Server System SR2500AL User s Guide 53 10 11 12 13 See the
144. nnzeichneten Netztaste wird das System NICHT vollst ndig vom Netz getrennt Es sind weiterhin 5 V aktiv solange das System eingesteckt ist Um das System vollst ndig vom Strom zu trennen mu das Netzkabel aus der Steckdose abgezogen werden Das System verf gt m glicherweise ber mehrere Netzkabel Vergewissern Sie sich in diesem Fall da alle Netzkabel abgezogen sind Wenn Sie Komponenten ein oder ausbauen m chten die nicht hot plug f hig sind stellen Sie sicher da zuvor alle Netzkabel abgezogen sind Nehmen Sie keine nderungen am Netzkabel vor und verwenden Sie kein Kabel das nicht genau dem geforderten Typ entspricht Jedes Netzteil im System mu ber ein eigenes Netzkabel angeschlossen werden Einige Netzteile von Intel Servern verwenden Nullleitersicherungen Vorsicht ist geboten im Umgang mit Netzteilen welche Nullleitersicherungen verwenden um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enth lt keine Teile die vom Benutzer gewartet werden k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netzkabel ab bevor Sie es aus dem Server ausbauen Zur Vermeidung von Stromschl gen schalten Sie den Server aus und trennen Sie vor dem ffnen des Ger ts das Netzkabel sowie alle a
145. ns on installing the server s cover Removing a Processor 1 Observe the safety and ESD precautions in Safety Information 2 Turn off all peripheral devices connected to the server Turn off the server 3 Remove the AC power cord s from the server 4 Remove the server s cover See the documentation that came with your server chassis for instructions on removing the server s cover 5 Unplug the processor fan cable from the server board Loosen the four captive screws on the corners of the heat sink Twist the heat sink slightly to break the seal between the heat sink and the processor 8 Liftthe heat sink from the processor If it does not pull up easily twist the heat sink again Do not force the heat sink from the processor Doing so could damage the processor 9 Lift the processor lever 10 Raise the CPU load plate 11 Remove the processor 12 If installing a replacement processor see Installing the Processor Otherwise install the protective socket cover over the empty processor socket and reinstall the chassis cover Removing and Installing the Small Air Baffle Some installation processes will require that you remove the small air baffle that is placed behind the hard drive bays near the front of your server The steps below describe how to remove and then install the small air baffle Use these steps only when it is indicated as necessary for a component installation process Always operate your serv
146. nuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de los productos Utilice s lo los componentes descritos y homologados que se especifican en esta gu a El uso de otros productos o componentes anular la homologaci n UL y otras certificaciones oficiales del producto pudiendo dejar de ser compatible con las normativas locales de los pa ses en los que se comercializa Advertencias y precauciones sobre seguridad Para reducir la posibilidad de que se produzcan lesiones personales o da os en la propiedad antes de empezar a instalar el producto lea observe y cumpla toda la informaci n e instrucciones de seguridad siguientes Puede que se utilicen los siguientes s mbolos de seguridad en la documentaci n y es posible que aparezcan en el producto o en su embalaje Indica la existencia de un riesgo que podr a causar lesiones personales o PRECAUCION da os en la propiedad leves si no se tiene en cuenta la PRECAUCI N Indica la existencia de un riesgo que podr a causar lesiones personales ADVERTENCIA graves si no se tiene en cuenta la ADVERTENCIA Intel Server System SR2500AL User s Guide 181 Indica un riesgo potencial si no se tiene en cuenta la informaci n indicada Indica riesgo de descargas el ctricas que podr an causar lesiones graves o la muerte si no se siguen las instrucciones de seguridad Indica componentes o superficies calientes
147. o the software updates In addition to the server firmware and files also update any drivers used for components you have installed in your system such as video drivers network drivers and SATA drivers Intel provides a package called the Platform Confidence Test that may help with your diagnostics See Server System References for a link to this software If you are unable to resolve your server problems on your own see Getting Help for assistance Resetting the System Before going through in depth troubleshooting attempt first to reset your system using one of the methods below Table 7 Resetting the System To do this Press Soft boot reset to clear the system memory and reload the operating lt Ctrl Alt Del gt system Clear system memory restart POST and reload the operating system Reset button Cold boot reset Turn the system power off and then on This clears Power off on system memory restarts POST reloads the operating system and halts button power to all peripherals Reset the BMC and get it back to a stable state Remove AC power from the server for one minute Problems following Initial System Installation Problems that occur at initial system startup are usually caused by an incorrect installation or configuration Hardware failure is a less frequent cause If the problem you are experiencing is with a specific software application see Problems with Newly Installed Applica
148. odule assembly For instructions see Replacing a Fan Module Place the server board into the server system as shown in the figure below see letter A and attach the server board with six screws see letter B AF000025 Figure 71 Installing the Server Board Intel Server System SR2500AL User s Guide 81 11 12 13 14 15 16 17 18 19 20 21 Removing t 1 10 11 12 82 Connect all power cables to the server board Install memory For instructions see Installing DIMMs Install processor s For instructions see Installing the Processor Install the fan module assembly For instructions see Replacing a Fan Module Install the large air baffle For instructions see Installing the Large Air Baffle Install the bridge board For instructions see Figure 64 Installing the Bridge Board into the Server System on page 73 Install the optical drive cable optional Install the PCI riser assembly For instructions see Installing the PCI Riser Assembly Install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server he Server Board Observe the safety and ESD precautions at the beginning of this book See Safety Information Po
149. on Caution To avoid personal injury or property damage the following safety instructions apply whenever accessing the inside of the product Turn off all peripheral devices connected to this product Turn off the system by pressing the power button to off Disconnect the AC power by unplugging all AC power cords from the system or wall outlet e Disconnect all cables and telecommunication lines that are connected to the system Retain all screws or other fasteners when removing access cover s Upon completion of accessing inside the product refasten access cover with original screws or fasteners Do not access the inside of the power supply There are no serviceable parts in the power supply Return to manufacturer for servicing e Power down the server and disconnect all power cords before adding or replacing any non hot plug component When replacing a hot plug power supply unplug the power cord to the power supply being replaced before removing the power supply from the server If the server has been running any installed processor s and heat sink s may be hot Unless you are adding or removing a hot plug component allow the system to cool before opening the covers To avoid the possibility of coming into contact with hot component s during a hot plug installation be careful when removing or installing the hot plug component s To avoid injury do not contact moving fan blades If your system is supplied
150. on data from memory SPD on DIMM 0x23h OFF OFF A G Detecting presence of memory 0x24h OFF G OFF Programming timing parameters in the memory controller 0x25h OFF G R G Configuring memory parameters in the memory controller 0x26h OFF G OFF Optimizing memory controller settings 0x27h OFF G G Initializing memory such as ECC init 0x28h G OFF OFF Testing memory 128 Intel Server System SR2500AL User s Guide Table 12 Diagnostic LED POST Code Decoder PCI Bus 0x50h OFF R OFF R Enumerating PCI busses 0x51h OFF R OFF A Allocating resources to PCI busses 0x52h OFF R G R Hot Plug PCI controller initialization 0x53h OFF R G A Reserved for PCI bus 0x54h OFF A OFF R Reserved for PCI bus 0x55h OFF A OFF A Reserved for PCI bus 0x56h OFF A G R Reserved for PCI bus 0x57h OFF A G A Reserved for PCI bus USB 0x58h G R OFF Resetting USB bus 0x59h G R OFF A Reserved for USB devices ATA ATAPI SATA Ox5Ah G R Resetting PATA SATA bus and all devices 0x5Bh G R A Reserved for ATA SMBUS 0x5Ch G A OFF R Resetting SMBUS 0x5Dh G A OFF A Reserved for SMBUS Local Console 0x70h OFF R R Resetting the video controller VGA 0x71h OFF R R A Disabling the video controller VGA 0x72h OFF R A R Enabling the video controller VGA Remote Console 0x78h G R R R Resetting the console
151. onents and to help you identify the server from among several servers Except for the ID LED the status LED and the 5V standby LED the LEDs turn on amber only ifa failure occurs cavi Light Gulded Diagnostics ae n RED il 5 rae n Legend a Bs iu nue A POST Code LEDs 9 B ID LED C Status LED D DIMM A1 Fault E DIMM A2 Fault F DIMM B1 Fault G DIMM B2 Fault H DIMM C1 Fault I DIMM C2 Fault P J DIMM D1 Fault M K DIMM D2 Fault 18 L CPU 1 Fault M CPU 2 Fault zo Se DIMM B2 DIMM C2 D DIMM D2 N 5V Standby O O o AF000644 Figure 6 Light Guided Diagnostic LEDs Intel Server System SR2500AL User s Guide 11 Back Panel Connectors
152. onnected to the system turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet To maintain proper system cooling a filler blank must be installed if you do not install a device at this location Intel Server System SR2500AL User s Guide 47 Installing a Slimline Optical Drive or Internal USB Floppy 48 1 10 11 12 13 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the front bezel if it is installed For instructions see Removing the Front Bezel Remove the server system cover For instructions see Removing the System Cover Insert the interposer board into the optical drive Obtain the optical drive and the drive tray Align the two holes on the left edge of the optical drive and interposer board with the two metal tabs in the tray as shown in Figure 38 see letter A Lower the opposite side of the optical drive into the tray until it clicks into place see letter B TP02147 Figure 38 Installing an Optical Drive into the Drive Tray Screw the interposer board into the carrier Insert the optical drive tray assembly into the server system as shown in Figure 39 see letter A Make sure that the back end of the interposer board plugs into the matching socket on
153. ontrol Panel See the diagrams below to identify your front bezel Note the orientation in the figures below the control panel is at the right If you are installing a bezel on your server system make sure you position it as shown AF000154 Figure 16 Front Bezel Supporting the Standard Control Panel AF000153 Figure 17 Front Bezel Supporting the Intel Local Control Panel 28 Intel Server System SR2500AL User s Guide Removing the Front Bezel Use the steps below if your system includes a front bezel 1 Unlock the bezel 2 Disconnect any cables attached to the control panel 3 Pull the bezel from the server system TP02129 Figure 18 Removing the Front Bezel Intel Server System SR2500AL User s Guide 29 Installing the Front Bezel Use the steps below if your system includes either the standard front bezel or the front bezel for the Intel Local Control Panel The front bezel is optional 1 Ateach end of the bezel line up the center notch on the bezel with the center guide on the rack handles 2 Push the bezel onto the front of the server system until it clicks into place 3 Connect any necessary cables to the front control panel area at the right side of the server system TP02130 Figure 19 Installing the Front Bezel Removing and Installing the System Cover Removing the System Cover The server system must be operated with the chassis cover in place to ensur
154. p Codes Generated by Intel Remote Management Module erg Reason for Beeps and Action to Take 1 Control panel CMOS clear has been initiated 1 5 1 1 Processor failure Reseat or replace the failed processor 1 5 2 1 No processor is installed or the CPU 1 socket is empty Reseat or replace the failed processor 1 5 2 3 Processor configuration error or CPU 1 socket is empty Reseat or replace the failed processor In a two processor system make sure the processors are identical 1 5 2 4 Front side bus select configuration error 1 5 4 2 DC power unexpectedly lost 1 5 4 3 Chipset control failure 1 5 4 4 Power control failure Intel Server System SR2500AL User s Guide 121 122 Intel Server System SR2500AL User s Guide Appendix C Intel Server Issue Report Form Note An on line automatic submission version of this form is available at http support intel com support motherboards server chassis SR2500 For the fastest service please submit your form via the Internet Date Submitted Company Name Contact Name Email Address Intel Server Product Priority Critical Hot High Low Brief Problem Description Provide a brief description below See the last page for space to include a detailed problem description Board Chassis Information Baseboard Revision PBA Baseboard Serial Number Chassis Model CPUI Speed Ste
155. post Align the face of the bracket foot with the inside edge of the rack post and firmly tighten the screws Repeat steps 8 to 10 above to install the other 3 brackets 2 front amp 2 back Ensure all brackets are at the same height on the rack Position a rail assembly middle and outer rails with its black plastic end caps toward the rear of the rack and its outer rail closest to the brackets Align the front screw hole in the outer rail with the threaded hole nearest the front of the front bracket and fit the rail assembly into the front and rear brackets Slide the middle rail toward the front until the access hole in the middle rail is aligned with the front screw hole in the outer rail Insert screw through the access hole and loosely attach the outer rail to the front bracket In a similar manner to steps 13 through 15 install a screw through a slot in the outer rail and into the rear most threaded hole in the front bracket Firmly tighten this Screw Firmly tighten the front screw installed loosely in step 15 In the same manner attach the other rail assembly to the other side Slide the middle rail toward the front until the rear bracket area 1s accessible Attach the rear end of the outer rail to the rear bracket with at least one screw If possible attach at two places In the same manner attach the other rail assembly to the other side Intel Server System SR2500AL User s Guide 22 Fully extend the left and
156. pping Spec CPU2 Speed Stepping Spec System BIOS Version HSC Firmware Version DIMM Configuration DIMM A1 MB and Vendor part number DIMM A2 MB and Vendor part number DIMM B1 MB and Vendor part number DIMM B2 MB and Vendor part number DIMM C1 MB and Vendor part number DIMM C2 MB and Vendor part number DIMM D1 MB and Vendor part number DIMM D2 MB and Vendor part number Operating System Information Operating System Version Service Pack Add in Card Peripheral Video NIC Check each box below as applicable and provide the requested information Peripheral Card or Peripheral Description Driver Revision IRQ VO Base Address NIC 1 0 Base FW Address Revision Driver Revision IRQ Peripheral Description PCI X Top PCI Slot Middle PCI Slot Bottom PCI Slot PCle x4 Top PCI Slot Middle PCI Slot Bottom PCI Slot PCle x8 Top PCI Slot Middle PCI Slot Bottom PCI Slot 124 Intel Server System SR2500AL User s Guide Peripheral Description Driver Revision IRQ 1 0 Base Address FW Revision Video On board Video Add in Video NIC On Board NIC1 On Board NIC2 Hard Drive Information Drive Type SCSI SATA etc Make Model Hot swap or Fixed IRQ FW Revision
157. r intel com ehs environmental htm None Required International 15011469 Plastic parts weighing gt 25gm are intended to be marked with per 15011469 gt PC ABS lt Recycling Markings Fiberboard FB and Cardboard CB are marked with international recycling marks Applied to outer bulk packaging and single package 2 ou Corrugated Recycles Japan Japan Recycling Applied to Retail Packaging Only for Boxed Boards Intel Server System SR2500AL User s Guide 145 Other Markings Table 15 Other Markings Compliance Compliance Reference Description Compliance Relerohige Marking Example Stand by Stand by Power Warnings Power Applied to product if stand by power switch is used O Multiple Power Cords Multiple Power Cords Warnings Applied to product if more than one power cord is used English This unit has more than one power supply cord To reduce the risk of electrical shock disconnect 2 two power supply cords before servicing Simplified Chinese OF ADA HEQI EA HI FE Z Akt ei SE Rb TrxttT AEE 2 BI ITPA C2 j SHIA EB Traditional Chinese 6F B Y of OSH O L Ais f E Weed y m ODE 2LO e s German Dieses Ger te hat mehr als ein Stromkabel Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide 2 Stromkabeln bevor Instandhaltung 14
158. r to country of origin marked on product CNCA CCC China The CCC Certification Marking and EMC warning is located on the outside rear area of the product AE HOA ABR Wh TEAR a TRE TX REX Hund CEREAL DEN ERA AAA HN of f 01485 ME Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements The following is Intel s product ecology compliance criteria Intel Server System SR2500AL User s Guide 143 Table 14 Product Ecology Compliance Markings Compliance Regional Description Compliance Reference Compliance Reference Marking Example California California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials Special handling may apply See www dtsc ca gov hazardouswaste perchlorate This notice is required by California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials This product part includes a battery which contains Perchlorate material China China RoHS Administrative Measures on the Control of Pollution Caused by Electronic Information Products ElP 39 Referred to as China RoHS Mark requires to be applied to retail products only Mark used is the Environmental Friendly Use Period EFUP Number represents years G China Recycling GB18455 200
159. r un composant non connectable chaud Les alimentations de certains serveurs Intel sont munies de doubles fusibles p le neutre veuillez observer les pr cautions d usage afin d viter tout risque d el ctrocution N essayez pas de modifier ou d utiliser un cordon d alimentation secteur s il ne s agit pas du type exact requis Un cordon secteur est requis pour chaque alimentation syst me Le bloc d alimentation de ce produit ne contient aucun composant r parable par l utilisateur N ouvrez pas le bloc d alimentation L int rieur de celui ci est soumis des Intel Server System SR2500AL User s Guide 177 niveaux dangereux de tension de courant et d nergie Renvoyez le au fabricant en cas de probl me Lorsque vous remplacez un bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de le retirer du serveur Pour viter tout risque d lectrocution mettez le syst me hors tension et d branchez les cordons d alimentation ainsi que les syst mes de t l communication r seaux et modems reli s au syst me avant d ouvrir ce dernier Avertissements sur le cordon d alimentation Si aucun cordon d alimentation secteur n a t fourni avec votre produit vous devez vous en procurer un qui soit approuv pour une utilisation dans votre pays Attention Pour viter tout risque d lectrocution ou d incendie v rifiez les cordons d alimentation qui seront utilis s avec le produi
160. rge Air Baffle Install the bridge board For instructions see Figure 64 Installing the Bridge Board into the Server System on page 73 Install the optical drive cable optional Install the PCI riser assembly For instructions see Installing the PCI Riser Assembly Install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Replacing a Redundant System Fan Note The fans that are integrated into the power supply cannot be replaced separately Ifone of the fans in the power supply fails the power supply must be replaced The system fans at the front of the server system can be individually replaced if one of them fails Use the steps below to replace a system fan 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Remove the server system cover For instructions see Removing the System Cover There are no screws to loosen Lift the failed fan from the module Intel Server System SR2500AL User s Guide 95 AF000004 Figure 85 Removing a Fan from the Redundant Fan Module 4 Position the replacement fan so the connector on the fan is at the right and pointing down Note Fan locations 1 2 3 and 4 use 80mm fans Fan locations 5 and 6 u
161. right rails until the extension locks have engaged and the rails will not push back in The rail system is now ready to receive the chassis Caution Lifting and placing the chassis in the rails is a two person job If needed use an appropriate lifting device 23 With the chassis front facing you lift the chassis and carefully insert the rails attached to the chassis in the extended rails 24 Slide the chassis toward the rear of the cabinet until the rails lock together 25 Depress and hold down the finger tabs on both extension locks while sliding the chassis toward the rear 26 Slide the chassis all the way into the rack until the chassis handles are against the front posts Basic Rail Rack Mount Removal 1 Disconnect all cables from the back of the system Note Remember to use the system LED to properly identify the system you are servicing 2 Pull system from rack until brackets are fully extended 3 Push in both clips on the brackets and slide the system forward until the inner rail separates from the outer rail 4 Remove and service the system Basic Rail Rack Mount Installation 1 Extend the inner rail until it locks 2 Depress the spring safety lock to release the inner rail 3 Remove the inner rail from the rail assembly 4 Attach the outer rail slides to the rack posts using two 10 32 x 1 2 screws at the front posts and two 10 32 x 1 2 screws at the rear posts Note The rail flanges mount to the in
162. rized distributor 150 Intel Server System SR2500AL User s Guide North America and Latin America To obtain warranty repair for the product please go to the following Web site to obtain instructions http support intel com support motherboards draform htm n Europe and in Asia Contact your original authorized distributor for warranty service Any replacement Product is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period Telephone Support If you cannot find the information you need on Intel s World Wide Web site http www intel com call your local distributor or an Intel Customer Support representative See Getting Help for telephone numbers Returning a Defective Product Before returning any product call your authorized dealer distribution authority Intel Server System SR2500AL User s Guide 151 152 Intel Server System SR2500AL User s Guide Appendix H Installation Assembly Safety Instructions English The power supply in this product contains no user serviceable parts Refer servicing only to qualified personnel Do not attempt to modify or use the supplied AC power cord if it is not the exact type required A product with more than one power supply will have a separate AC power cord for each supply The power button on the system does not turn off system AC power To remove AC power from the sy
163. roduct and will most likely result in noncompliance with product regulations in the region s in which the product is sold System power on off The power button DOES NOT turn off the system AC power To remove power from system you must unplug the AC power cord from the wall outlet Make sure the AC power cord is unplugged before you open the chassis add or remove any components Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts ESD and handling boards Always handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide board over any surface
164. roperly grounded wall outlet Provided with sufficient space to access the power supply cord s because they serve as the product s main power disconnect Intel Server System SR2500AL User s Guide Deutsch Benutzer k nnen am Netzger t dieses Produkts keine Reparaturen vornehmen Das Produkt enth lt m glicherweise mehrere Netzger te Wartungsarbeiten m ssen von qualifizierten Technikern ausgef hrt werden Versuchen Sie nicht das mitgelieferte Netzkabel zu ndern oder zu verwenden wenn es sich nicht genau um den erforderlichen Typ handelt Ein Produkt mit mehreren Netzger ten hat f r jedes Netzger t ein eigenes Netzkabel Der Wechselstrom des Systems wird durch den Ein Aus Schalter f r Gleichstrom nicht ausgeschaltet Ziehen Sie jedes Wechselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripherieger te aus 2 Schalten Sie das System mit dem Hauptschalter aus 3 Ziehen Sie den Stromanschlu stecker Ihres Systems aus der Steckdose 4 Auf der R ckseite des Systems beschriften und ziehen Sie alle Anschlu kabel von den I O Anschl ssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD
165. roumgebungen geeignet W hlen Sie einen Standort der folgenden Kriterien entspricht Sauber trocken und frei von Partikeln in der Luft au er dem normalen Raumstaub Gut bel ftet nicht in der N he von W rmequellen und keiner direkten Sonnenbestrahlung ausgesetzt Nicht in der N he von Vibrations oder Ersch tterungsquellen Abgeschirmt von starken elektromagnetischen Feldern die durch elektrische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspannungsschutz anschlie en und bei einem Gewitter die Telekommunikationskabel zum Modem abziehen Eine ordnungsgem geerdete Wandsteckdose mu vorhanden sein Ausreichender Freiraum f r den Zugang zu den Netzkabeln da diese die Hauptvorrichtung zum Trennen des Produkts von der Stromversorgung sind Handhabung von Ger ten Beachten Sie zur Vermeidung von Verletzungen oder Besch digungen an den Ger ten die folgenden Hinweise Halten Sie beim Transportieren und Anheben von Ger ten die rtlichen Gesundheits und Sicherheitsvorschriften ein Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Ger ten Entfernen Sie alle Komponenten die sich leicht abnehmen lassen um das Gewicht zu reduzieren und die Handhabung zu erleichtern Intel Server System SR2500AL User s Guide 171 Warnungen zu Netzspannung und Elektrizit t Caution Durch Bet tigen der mit dem Standby Symbol geke
166. rt werden um ein Umkippen zu vermeiden wenn ein Server oder andere Ger te herausgezogen werden Bei der Installation des Racks m ssen die Anweisungen des Rack Herstellers beachtet werden Gehen Sie bei der Installation von Ger ten im Rack immer von unten nach oben vor und bauen Sie das schwerste Ger t an der untersten Position im Rack ein Ziehen Sie jeweils immer nur ein Ger t aus dem Rack heraus Intel Server System SR2500AL User s Guide 173 Sie m ssen f r die gesamte Rack Einheit einen Netztrennschalter einrichten Dieser Netztrennschalter mu leicht zug nglich sein und ber eine Kennzeichnung verf gen die besagt da er die Stromzufuhr zur gesamten Einheit steuert und nicht nur zu den Servern Zur Vermeidung von Stromschlaggefahr m ssen das Rack selbst und alle darin eingebauten Ger te ordnungsgem geerdet sein Elektrostatische Entladungen ESD Caution Elektrostatische Entladungen k nnen zur Besch digung von Festplatten Platinen und anderen Komponenten f hren Daher sollten Sie alle Arbeiten an einer ESD Workstation ausf hren Steht ein solcher Arbeitsplatz nicht zur Verf gung erzielen Sie einen gewissen Schutz vor elektrostatischen Entladungen durch Tragen einer Antistatik Manschette die Sie w hrend der Arbeit zur Erdung an einem beliebigen unlackierten Metallteil des Computergeh uses befestigen Gehen Sie bei der Handhabung von Platinen immer mit gr ter Vorsicht vor Sie k nnen u erst empf
167. s that require them See your add in card documentation for information and add in card requirements Re install the processor air duct For instructions see Installing the Processor Air Duct Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server and Removing a PCI Add in Card The instructions below describe how to install and remove a PCI add in card Installing a PCI Add in Card 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the processor air duct For instructions see Removing the Processor Air Duct Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Open the rear retention clip by pushing the blue slide upward and rotating clip to the fully open position see letter A Open the front retention clip by rotating 90 degrees outward see letter B Remove the filler panel from the selected add in card slot see letter C Insert add in card until it seats in riser card connector see letter D Intel Server System SR2500AL User s Guide 63 AF000148 Figure 55 Installing a Full Height Add In Car
168. se 60mm fans 5 With the fan oriented correctly insert the fan into the fan module engaging the connector on the fan into the matching connector on the fan module AF000009 Figure 86 Installing a Fan into the Redundant Fan Module 96 Intel Server System SR2500AL User s Guide 6 Install the server system cover For instructions see Installing the Server System Cover Replacing a Fixed Fan Caution The system fans are NOT hot swappable Before removing or replacing a fan you must first take the server out of service turn off all peripheral devices connected to the system turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet Note The fans that are integrated into the power supply cannot be replaced separately Ifone of the fans in the power supply fails the power supply must be replaced The system fans at the front of the server system can be individually replaced if one of them fails Use the steps below to replace a fan 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the fan module assembly For instructions see Replacing a Fan Module There are no screws to loosen Remove the fan from the fan module se
169. see Removing the Large Air Baffle Remove the cable from the rear of the RAID battery backup unit and the mid plane board as shown in the figure below see letter A Slide the RAID battery backup unit forward and lift from the server system see letter B AF000150 Figure 70 Removing the RAID Battery Backup Unit Install the large air baffle For instructions see Installing the Large Air Baffle Install the server system cover For instructions see Installing the Server System Cover Plug all peripheral devices and the AC power cable s into the server Intel Server System SR2500AL User s Guide Installing and Removing the Server Board Installing the Server Board 1 10 Observe the safety and ESD precautions at the beginning of this book See Safety Information Power down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the processor air duct For instructions see Removing the Processor Air Duct Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Remove the optical drive cable if installed Remove the bridge board For instructions see Figure 61 Removing the Bridge Board from the Server System on page 71 Remove the large air baffle For instructions see Removing the Large Air Baffle Remove the fan m
170. ser s Guide 57 3 Remove the server system cover For instructions see Removing the System Cover 4 Remove the processor air duct by lifting straight up Disconnect any cables attached to any add in cards 6 Grasp both riser latches with thumb and forefinger see letter A and pull up to release riser assembly 7 Lift riser assembly straight up see letter B TP02145 Figure 51 Removing PCI Riser Assembly from the Server System 8 Ifyou need to add or replace a PCI add in card see Installing and Removing a PCI Add in Card 9 Ifyou need to add or replace a PCI riser connector see Replacing a PCI Riser Card 10 If you removed the PCI riser assembly for another procedure continue with that procedure 58 Intel Server System SR2500AL User s Guide Installing the PCI Riser Assembly 1 Lower the riser assembly into place see letter A 2 Align the three hooks in the riser assembly with the matching slots at the back of the server system see letter B TP02146 Figure 52 Installing PCI Riser Assembly into the Server System 3 Press down uniformly until the three hooks on the rear of the PCI riser assembly engage the server system back panel slots The riser cards will seat into the matching sockets on the server board 4 Connect any cables to add in cards that require them See your add in card documentation for information and add in card requirements 5 Re instal
171. side of each post 5 Insert the inner rails over the server chassis sidewall studs 6 Slide the inner rails toward the front of the server chassis 7 Secure the inner rails with one 6 32 x 1 4 screw for each rail 8 Align the inner rails attached to the server chassis with the outer rail assemblies attached to the rack 9 Engage the matching rails and slide the server chassis into the rack until the two safety stops lock into position 10 Depress the two safety locks one on each side Intel Server System SR2500AL User s Guide 27 11 Slide the server chassis all the way into the rack 12 Use the rack screws 10 32 x 3 4 to secure the chassis and rack handles into the rack Tool less Rail Rack Mount Servicing To service the system pull the system out from the rack Disconnect the power cable s and proceed with servicing the system When the servicing is completed re connect the power cable s SO e gt Pull up on the green tabs on each rail and slide the system back into the rack Note Beware of cables when re installing the system into the rack so that the cables do not get pulled or interfered with Removing and Installing the Front Bezel The front bezels are available as optional accessories for the Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP Two front bezel options are available One is used for the standard control panel and the other 1s used with the Intel Local C
172. sis Two bezels are available One fits a system that has the standard control panel installed The other is used for a chassis with the other Intel Local Control Panel Each bezel provides a lock to secure the hard drive and optical drive area For instructions on installing either of the front bezels see Installing the Front Bezel The order numbers for the bezels are e ADWBEZBLACK Black bezel for use with the standard control panel ADWLCDBEZEL Black bezel for use with the Intel Local Control Panel 20 Intel Server System SR2500AL User s Guide Rear of Server System ouuu BE JU DO DOU800800n nnmnimmu TP02125 Server Management NIC Optional RJ45 Serial B Connector 1 0 Module Optional A Low Profile Add in Card Slots USB6 B Full Height PCI Add in Card Slots J USB5 C Upper Power Supply Module K Video D Upper Power Receptacle L DB 9 Serial A Connector Knockout E Lower Power Receptacle M NIC2 F Lower Power Supply Module N NIC 1 G O H P PS2 Keyboard and Mouse Connectors Figure 14 Server System Back Intel Server System SR2500AL User s Guide 21 Peripheral Devices The server system provides locations and hardware for installing hard drives a USB floppy
173. stem you must unplug each AC power cord from the wall outlet or power supply The power cord s is considered the disconnect device to the main AC power The socket outlet that the system plugs into shall be installed near the equipment and shall be easily accessible SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connected to the system 2 Turn off the system by pressing the power button 3 Unplug all AC power cords from the system or from wall outlets 4 Label and disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components 6 Do not operate the system with the chassis covers removed Intel Server System SR2500AL User s Guide 153 154 After you have completed the six SAFETY steps above you can remove the system covers To do this 1 Unlock and remove the padlock from the back of the system if a padlock has been installed 2 Remove and save all screws from the covers 3 Remove the cover s For proper cooling and airflow always reinstall the chassis covers before turning on the system Operating the system without the covers in place can damage system parts To install the covers 1
174. stem SR2500AL User s Guide Front of Server System Standard Control Panel 18 The diagram below shows the features available on the standard control panel Another option is the Intel Local Control Panel which is discussed next E O A i e Or o gt B CD E tes BEA gt gt O O O O J AF000030 Callout Feature Function A NIC 2 Activity LED Continuous green light indicates a link between the system and B NIC 1 Activity LED the network to which it is connected Blinking green light indicates network activity C Power Sleep Button Continuous green light indicates a link between the system and the network to which it is connected Blinking green light indicates network activity D Power Sleep LED owe green light indicates the system has power applied to it Blinking green indicates the system is in S1 sleep state No light indicates the power is off is in ACPI S4 or S5 state E Hard Disk Drive Random blinking green light indicates hard disk drive activity SAS Activity LED or SATA No light indicates no hard disk drive activity F System Status LED Solid green indicates normal operation Blinking green indicates degraded performance Solid amber indicates a critical or non recoverable condition Blinking amber indicates a non critical condition No light indicates POST is running or the system is off G System Identification Solid blue indicates system
175. stem SR2500ALBRP SR2500ALBRPR ships with the following items Intel Server Board S5000PAL installed in the server system One 750 W power supply module installed in the server system A box of hardware components referred to below as the hardware box Low profile riser installed in the server system Full height profile riser installed in the server system Optical drive tray assembly in the hardware box Bridge board installed in the server system Optical drive cable installed in the server system Chassis intrusion switch integrated into the server system riser Attention document in the server system product box Quick Start User s Guide in the server system product box One 32 6mm flat screw for installing the optical drive component in the hardware box Rack handles in the hardware box Peripheral bay filler panel in the hardware box Standard control panel installed in the server system Passive mid plane installed in the server system Intel Server System SR2500AL User s Guide Intel Server System SR2500AL User s Guide Table of Contents Safety Information aro iii Important Safety Instructions unten di caber iii Wichtige Sicherheitshinweise issus iii Consignes de sesunte ana A REAREN iii Instrucciones de seguridad importantes nenn iii inre m vii ABOUL this Manual aci ee ee ee vii Manual Organization paso ias vii Produc OMS epscop ankaka aar
176. sufficient space to access the power supply cord s because they serve as the product s main power disconnect Equipment Handling Practices 166 Reduce the risk of personal injury or equipment damage Conform to local occupational health and safety requirements when moving and lifting equipment Use mechanical assistance or other suitable assistance when moving and lifting equipment To reduce the weight for easier handling remove any easily detachable components Intel Server System SR2500AL User s Guide Power and Electrical Warnings Caution The power button indicated by the stand by power marking DOES NOT completely turn off the system AC power 5V standby power is active whenever the system is plugged in To remove power from system you must unplug the AC power cord from the wall outlet Your system may use more than one AC power cord Make sure all AC power cords are unplugged Make sure the AC power cord s is are unplugged before you open the chassis or add or remove any non hot plug components Do not attempt to modify or use an AC power cord if it is not the exact type required A separate AC cord is required for each system power supply Some power supplies in Intel servers use Neutral Pole F using To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing The power supply in this product contains no user serviceable parts Do not open the power supply Hazardous voltage
177. t a sub field for multi valued features like time and date If a pick list is displayed the Enter key will undo the pick list and allow another selection in the parent menu Esc Exit The Esc key provides a mechanism for backing out of any field This key will undo the pressing of the Enter key When the Esc key is pressed while editing any field or selecting features of a menu the parent menu is re entered When the Esc key is pressed in any submenu the parent menu is re entered When the Esc key is pressed in any major menu the exit confirmation window is displayed and the user is asked whether changes can be discarded F9 102 Setup Defaults Pressing F9 causes the following to appear Setup Confirmation Load default configuration now Yes No If Yes is selected and the Enter key is pressed all Setup fields are set to their default values If No is selected and the Enter key is pressed or if the Esc key is pressed the user is returned to where they were before F9 was pressed without affecting any existing field values Intel Server System SR2500AL User s Guide Table 4 Setup Menu Key Use Key to Press Description lt F10 gt Save and Exit Pressing lt F10 gt causes the following message to appear Setup Confirmation Save Configuration changes and exit now Yes No If Yes is selected and the Enter key is pressed all changes are
178. t comme suit e N essayez pas d utiliser ou de modifier les cordons d alimentation en CA s ils ne correspondent pas exactement au type requis pour les prises lectriques reli es la terre Les cordons d alimentation doivent r pondre aux crit res suivants Le cordon d alimentation doit supporter une intensit sup rieure celle indiqu e sur le produit Le cordon d alimentation doit poss der une broche ou un contact de mise la terre appropri la prise lectrique Les cordons d alimentation lectrique repr sentent le principal dispositif de d connexion raccord l alimentation secteur Les prises de courant doivent se trouver proximit de l quipement et tre facilement accessibles pour une d connexion Les cordons d alimentation doivent tre branch s sur des prises lectriques correctement reli es la terre Avertissements sur l acc s au syst me AA Attention Pour viter de vous blesser ou d endommager votre quipement les consignes de s curit suivantes s appliquent chaque fois que vous acc dez l int rieur du produit Mettez hors tension tous les p riph riques connect s ce produit e teignez le systeme en appuyant sur le bouton d alimentation D connectez l alimentation secteur en d branchant tous les cordons d alimentation secteur du syst me ou de la prise murale D connectez l ensemble des c bles et lignes de t l communication qui sont
179. t of the fan assembly see letter C in the figure below AF000164 Figure 61 Removing the Bridge Board from the Server System 6 Remove the fan module For instructions see Replacing a Fan Module 7 Hold the mid plane board only by the edges Slide the mid plane board back to release it from the backplane see letter A in the figure below Intel Server System SR2500AL User s Guide 71 8 Lift the mid plane board over the retention pins see letter B in the figure below and out of the server system AF000014 Figure 62 Removing the Mid plane from the Server System Installing the Mid plane Board 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the server system cover For instructions see Removing the System Cover 4 Position the mid plane board over the retention pins as shown in the figure below see letter A 5 Slide the mid plane board forward see letter B and insert the mid plane into the backplane connector as shown 72 Intel Server System SR2500AL User s Guide AF000015 Figure 63 Installing the Mid plane into the Server System 6 Connect cables as necessary to the mid plane board 7 Install the fan module For instructions see Replacing a Fan Module 8 Install the bridge boar
180. t the bottom edge of the DIMM into the socket When the DIMM is inserted push down on the top edge of the DIMM until the retaining clips snap into place see letter C in the figure above Make sure the clips are firmly in place see letter D in the figure above Intel Server System SR2500AL User s Guide 11 Replace the server s cover and reconnect the AC power cord s See the documentation that came with your server chassis for instructions on installing the server s cover Removing DIMMs To remove a DIMM follow these steps 1 2 3 4 Observe the safety and ESD precautions in Safety Information Turn off all peripheral devices connected to the server Turn off the server Remove the AC power cord s from the server Remove the server s cover See the documentation that came with your server chassis for instructions on removing the server s cover Gently spread the retaining clips at each end of the socket The DIMM lifts from the socket Holding the DIMM by the edges lift it from the socket and store it in an anti static package Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets Replace the server s cover and reconnect the AC power cord s See the documentation that came with your server chassis for instructions on installing the server s cover Installing or Replacing the Processor Caution Processor must be appropriate You may damage the server board
181. tem SR2500AL User s Guide 77 7 Install the large air baffle For instructions see Installing the Large Air Baffle 8 Install the server system cover For instructions see Installing the Server System Cover 9 Plug all peripheral devices and the AC power cable s into the server Removing the RAID Activation Key and the RAID Mini DIMM 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information 2 Power down the server and unplug all peripheral devices and the AC power cable s 3 Remove the server system cover For instructions see Removing the System Cover 4 Remove the large air baffle For instructions see Removing the Large Air Baffle 5 Remove the RAID activation key by lifting straight up see letter A in the figure below 6 Remove the RAID mini DIMM by releasing the retention mechanism see letter B in the figure below and pulling the DIMM out of the socket see letter C in the figure below AF000745 Figure 68 Removing the RAID Activation Key and the RAID Mini DIMM 7 Install the large air baffle For instructions see Installing the Large Air Baffle 8 Install the server system cover For instructions see Installing the Server System Cover 9 Plug all peripheral devices and the AC power cable s into the server 78 Intel Server System SR2500AL User s Guide Installing and Removing the RAID Battery Ba
182. ting from any breach of warranty under another legal theory including but not limited to lost profits downtime goodwill damage to or replacement of equipment and property and any costs of recovering reprogramming or reproducing any program or data stored in or used with a system containing this product Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This limited warranty gives you specific legal rights and you may also have other rights that vary from jurisdiction to jurisdiction Any and all disputes arising under or related to this Limited Warranty shall be adjudicated in the following forums and governed by the following laws for the United States of America Canada North America and South America the forum shall be Santa Clara California USA and the applicable law shall be that of the State of California USA for the Asia Pacific region the forum shall be Singapore and the applicable law shall be that of Singapore for Europe and the rest of the world the forum shall be London and the applicable law shall be that of the United Kingdom In the event of any conflict between the English language version and any other translated version s of this Limited Warranty the English language version shall control How to Obtain Warranty Service To obtain warranty service for this Product you may contact Intel or your autho
183. tion Software First Steps Checklist Is AC power available at the wall outlet Are the power supplies plugged in Check the AC cable s on the back of the chassis and at the AC source Are all cables correctly connected and secured Are the processors fully seated in their sockets on the server board Are all standoffs in the proper location and not touching any components causing a potential short Are all add in PCI boards fully seated in their slots on the server board Are all jumper settings on the server board correct Are all jumper and switch settings on add in boards and peripheral devices correct To check these settings refer to the manufacturer s documentation that comes with them If applicable ensure that there are no conflicts for example two add in boards sharing the same interrupt Are all peripheral devices installed correctly If the system has a hard disk drive is it properly formatted or configured Are all device drivers properly installed Are the configuration settings made in Setup correct Is the operating system properly loaded See the operating system documentation Did you press the system power on off switch on the front panel to turn the server on power on light should be lit Is the system power cord properly connected to the system and plugged into a NEMA 5 15R outlet for 100 120V or a NEMA 6 15R outlet for 200 240V Are all integrated components from the tested components lists Ch
184. tion of Key System Lights As POST determines the system configuration it tests for the presence of each mass storage device installed in the system As each device is checked its activity light should turn on briefly Check for the following Does the drive activity light turn on briefly If not see Drive Activity Light Does Not Light If system LEDs are illuminated see Make sure the BIOS is configured to allow the CD ROM to be the first bootable device for a description of the light and steps to take to correct the problem Confirming Loading of the Operating System Once the system boots up the operating system prompt appears on the screen The prompt varies according to the operating system Ifthe operating system prompt does not appear see No Characters Appear on Screen Specific Problems and Corrective Actions This section provides possible solutions for these specific problems Power light does not light No characters appear on screen Characters on the screen appear distorted or incorrect Intel Server System SR2500AL User s Guide 113 System cooling fans do not rotate Diskette drive activity light does not light Hard disk drive activity light does not light CD ROM drive activity light does not light There are problems with application software The bootable CD ROM is not detected Try the solutions below in the order given If you cannot correct the problem contact your service r
185. to tal y como se describe a continuaci n No intente modificar ni utilizar los cables de alimentaci n de CA si no son exactamente del modelo especificado para ajustarse a las tomas de corriente conectadas a tierra Los cables de alimentaci n deben reunir los siguientes requisitos El cable de alimentaci n debe disponer de una capacidad nominal de corriente el ctrica mayor que la capacidad especificada en el producto El cable de alimentaci n debe disponer de una patilla o contacto de conexi n a tierra que sea apto para la toma de corriente Los cables de la fuente de alimentaci n son los dispositivos de desconexi n principales a la corriente alterna El enchufe o enchufes de z calo deben encontrarse cerca del equipo y el acceso a ellos debe poderse efectuar de forma inmediata con el fin de desconectarlos Los cables de la fuente de alimentaci n deben estar conectados a los enchufes con una toma de tierra adecuada Advertencias el acceso al sistema AM Precauci n Para evitar lesiones personales o da os en la propiedad se aplican las siguientes instrucciones de seguridad siempre que se acceda al interior del producto 184 Apague todos los dispositivos perif ricos conectados a este producto Pulse el bot n de alimentaci n para apagar el sistema Desconecte la alimentaci n de CA desenchufando los cables de alimentaci n de CA del sistema o de la toma de corriente alterna Desconecte todos los cables y l
186. troller for 10 100 1000 Mbit sec Ethernet LAN connectivity Expansion Capabilities One low profile riser slot supporting 1U or 2U PCI Express riser cards One full height riser slot supporting 1U or 2U PCI X and PCI Express riser cards Intel Server System SR2500AL User s Guide Table 2 Intel Server System SR2500ALLX and or the Intel Server System SR2500ALBRP Feature Summary Feature Description Hard Drives Five hot swap SATA SAS drives Drive bay for sixth hot swap SATA SAS drive or a 3 5 inch tape drive Peripherals Slimline bay for IDE optical drive PCI riser card bracket Control Panel dependent on option selected Standard control panel e Intel Local Control Panel LEDs and displays dependent on option selected With standard control panel NIC1 Activity NIC2 Activity Power Sleep System Status System Identification Hard Drive Activity With Intel Local Control Panel NIC1 Activity NIC2 Activity Power Sleep System Status System Identification Hard Drive Activity LCD Display Power Supply Up to two 750W power supply modules Fans Non redundant three fan option BRP Redundant fan module option containing six system fans LX Two non redundant fans in power supply USB Two front panel USB ports One internal USB header providing two USB ports System Management Intel System Management Software Intel Server Syste
187. ttes aux orages magn tiques nous vous recommandons de brancher votre syst me un suppresseur de surtension et de d connecter les lignes de t l communication de votre modem pendant les orages e Equip d une prise murale reli e la terre e quip d un espace suffisant pour acc der aux cordons d alimentation secteur car ils servent de disjoncteur principal d alimentation du produit Pratiques de manipulation de l quipement R duisez le risque de dommages personnels ou mat riels Conformez vous aux exigences de m decine du travail et de s curit lorsque vous d placez et soulevez le mat riel Utilisez l assistance m canique ou toute autre assistance appropri e lorsque vous d placez et soulevez le mat riel Pour r duire le poids en vue de faciliter la manipulation retirez tout composant amovible Alimentation et avertissements en mati re d lectricit AA Attention Le bouton d alimentation indiqu par le symbole de mise en veille NE COUPE PAS compl tement l alimentation secteur du syst me car le courant de veille 5 V reste actif lorsque le syst me est sous tension Pour couper l alimentation du syst me vous devez d brancher le cordon d alimentation secteur de la prise murale Votre syst me peut utiliser plusieurs cordons d alimentation secteur Assurez vous que tous les cordons d alimentation sont d branch s Vous devez les d brancher avant d ouvrir le ch ssis d ajouter ou de supprime
188. uct furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty Intel at 1ts option will REPAIR the Product by means of hardware and or software OR e REPLACE the Product with another Product OR REFUND the then current value of the Product if Intel is unable to repair or replace the Product If such Product is defective transportation charges for the return of Product to buyer within the USA will be paid by Intel For all other locations the warranty excludes all costs of shipping customs clearance and other related charges Intel will have a reasonable time to make repairs or to replace Product or to refund the then current value of the Product In no event will Intel be liable for any other costs associated with the replacement or repair of Product including labor installation or other costs incurred by buyer and in particular any costs relating to the removal or replacement of any product soldered or otherwise permanently affixed to any printed circuit board This Limited Warranty and any implied warranties that may exist under state law apply only to the original purchaser of the Product Extent of Limited Warranty Intel does not warrant that Products to be delivered hereunder whether delivered stand alone or integrated with other Products including without limitation semiconductor components will be free from design defects or errors
189. ue que vous manipulez les pieces Manipulez toujours les cartes avec precaution Elles peuvent tre extr mement sensibles aux ESD Ne tenez les cartes que par leurs bords Apres avoir retir une carte de son emballage de protection ou du serveur placez la sur une surface reliee a la terre exempte de charge statique composants orient s vers le haut Utilisez si possible un tapis de mousse conducteur mais pas l emballage de la carte Veillez ce que la carte ne glisse sur aucune surface Autres risques Remplacement de la pile Attention Il existe un risque d explosion si la pile n est pas correctement remplac e Lors du remplacement de la pile utilisez uniquement celle recommandee par le fabricant du mat riel Mettez la pile au rebut en vous conformant aux r glementations locales N essayez pas de recharger une pile N essayez pas de d monter de percer ou d endommager la pile d une quelconque fa on Refroidissement et ventilation 180 A Attention Routez les c bles avec pr caution comme indiqu pour minimiser les blocages de circulation d air et les problemes de refroidissement Afin de permettre une ventilation et un refroidissement corrects ne mettez le systeme en marche que lorsque les panneaux du ch ssis sont en place L utilisation du syst me sans les panneaux peut endommager les composants syst me Pour installer les panneaux V rifiez tout d abord que vous n avez pas oubli d outils ou
190. ult warning Control panel Green or Green No Fault Status and board rear Amber e left corner Green blinking degraded condition Amber blinking non critical error Amber critical or non recoverable error BIOS POST Beep Codes The table below lists the POST error beep codes Prior to system video initialization the BIOS uses these beep codes to inform users of error conditions Please note that not all error conditions are supported by BIOS beep codes Table 9 POST Error Beep Codes Number of Beeps Reason for Beeps and Action to Take 1 2 or 3 Memory error Reseat the memory or replace the DIMMs with known good modules 4 7or9 11 Fatal error indicating a possible serious system problem Remove all add in cards and re start the system If the error still occurs contact your system manufacturer If the beep codes are not generated after the add in cards are removed insert the cards one at a time booting the system between each card addition until the beeps again occur to reveal the malfunctioning card Replace or reseat the system video add in card If on board video is bing used the server board may be faulty 120 Intel Server System SR2500AL User s Guide In addition to the beep codes above additional beep codes are provided if an Intel Remote Management Module is installed The Intel Remote Management Module provides the following additional beep codes Table 10 Error Bee
191. ver Board S5000PAL User s Guide There are two versions of this server system the Intel Server System SR2500ALLX SR2500ALLXR SAS SATA version and the Intel Server System SR2500ALBRP SR2500ALBRPR SATA only version The contents of each server system are listed below Intel Server System SR2500ALLX SR2500ALLXR Contents Your Intel Server System SR2500ALLX SR2500ALLXR ships with the following items viii Intel Server Board S5000PAL installed in the server system One 750 W power supply module installed in the server system A box of hardware components referred to below as the hardware box Low profile riser installed in the server system Full height profile riser installed in the server system Optical drive tray assembly in hardware box Bridge board installed in the server system Optical drive cable installed in the server system Chassis intrusion switch integrated into the server system riser Attention document in the server system product box Quick Start User s Guide in the server system product box One 32 6mm flat screw for installing the optical drive component in the hardware box Rack handles in the hardware box Peripheral bay filler panel in the hardware box Standard control panel installed in the server system Active SAS SATA mid plane installed in the server system Intel Server System SR2500AL User s Guide Intel Server System SR2500ALBRP SR2500ALBRPR Contents Your Intel Server Sy
192. ver System SR2500AL User s Guide Table 13 Product Regulatory Compliance Markings Compliance Regional Compliance i z Description Reference Compliance Reference Marking Example CENELEC Europe Low Voltage Directive 93 68 EEC EMC Directive 89 336 EEC EN55022 Emissions EN55024 Immunity EN61000 3 2 Harmonics EN61000 3 3 Voltage Flicker CE Declaration of CE Conformity Germany GS Certification EN60950 j S International CB Certification None Required IEC60950 CISPR 22 CISPR 24 Japan VCCI Certification LH MIS 50377 a Matti HECTOR R TC MOS 2 A 2 31 T ZEDO RS LGDUBTICOGu r FI aM 5538 49J PE EDS gi MELO EDO ET VOCIA Korea RRL Certification MIC Notice No 1997 41 EMC amp 1997 42 EMI c2 PACA CPU Intel Server System SR2500AL User s Guide 139 140 Table 13 Product Regulatory Compliance Markings Compliance Regional Description Compliance Reference Compliance Reference Marking Example Russia GOST R Certification GOST R 29216 91 Emissions GOST R 50628 95 Immunity es Ukraine Ukraine Certification None Required Taiwan BSMI CNS13438 O R33025 FERAS i 2 RRA IRA RENTERS gt TENA TR GLARE gt EEE WR RM ws RI Intel Server System SR2500AL User s Guide Electromagnetic Compatibility Notices FCC Verification Statement USA This device complies with Part 15
193. video controller may have failed Contact your service representative or authorized dealer for help Characters Are Distorted or Incorrect Check the following Are the brightness and contrast controls properly adjusted on the video monitor See the manufacturer s documentation Are the video monitor s signal and power cables properly installed Does this video monitor work correctly if plugged into a different system System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly it is an indication of possible system component failure Check the following Intel Server System SR2500AL User s Guide 115 Is the power on light lit If not see Power Light Does Not Light If your system has LED lights for the fans is one or more of these LEDs lit Are any other control panel LEDs lit Have any of the fan motors stopped Use the server management subsystem to check the fan status Have your fans speeded up in response to an overheating situation Have your fans speeded up in response to a fan that has failed Are the fan power connectors properly connected to the server board e Is the cable from the control panel board connected to the both the control panel board and to the server board Are the power supply cables properly connected to the server board e Are there any shorted wires caused by pinched cables or have power connector plugs been forced into power conne
194. wer down the server and unplug all peripheral devices and the AC power cable s Remove the server system cover For instructions see Removing the System Cover Remove the processor air duct For instructions see Removing the Processor Air Duct Remove the PCI riser assembly For instructions see Removing the PCI Riser Assembly Remove the optical drive cable if installed Remove the bridge board For instructions see Figure 61 Removing the Bridge Board from the Server System on page 71 Remove the large air baffle For instructions see Removing the Large Air Baffle Remove the fan module assembly For instructions see Replacing a Fan Module Disconnect all cables from the server board Remove memory For instructions see Removing DIMMs Remove the processor s For instructions see Removing a Processor Intel Server System SR2500AL User s Guide 13 14 15 16 17 18 19 20 21 22 23 Remove the six screws from the server board see letter A and lift the server board from the server system see letter B AF000026 Figure 72 Removing the Server Board Replace the server board For instructions see Installing the Server Board Connect all power cables to the server board Install the fan module assembly For instructions see Replacing a Fan Module Install the large air baffle For instructions see Installing the L
195. with a guard over the fan do not operate the system without the fan guard in place Rack Mount Warnings 168 The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it The equipment rack must be installed according to the rack manufacturer s instructions Install equipment in the rack from the bottom up with the heaviest equipment at the bottom of the rack Extend only one piece of equipment from the rack at a time You are responsible for installing a main power disconnect for the entire rack unit This main disconnect must be readily accessible and it must be labeled as controlling power to the entire unit not just to the server s To avoid risk of potential electric shock a proper safety ground must be implemented for the rack and each piece of equipment installed in it Intel Server System SR2500AL User s Guide Electrostatic Discharge ESD Caution ESD can damage disk drives boards and other parts We recommend that you perform all procedures at an ESD workstation Ifone is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts Always handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the boar
Download Pdf Manuals
Related Search
Related Contents
WARNING - Cornerstone Mantels User manual D-2/16 仕様書 (カスタム TAL Nuclease 作製) 2.4 GHz Cordless Telephone DT 9812 Waveform Generator Operating Manual V2.0 BGS460SS 46 cm Steam oven with grill Elixir 4GB PC3-12800 La narrative des Stinger en Afghanistan Cette présentation vient en Copyright © All rights reserved.