1. 3 Insert the line from the wall receptacle into the port lableled LINE See Figure 3 Loading Paper Use the following procedure to load paper into the ICE 5500Plus terminal Note Use only thermal roll paper 1 Squeeze the paper cover tabs and lift open the paper cover See Figure 4 2 Place the paper roll into the holder so the paper feeds from under the roll Pull the end of the paper roll over the printer See Figure 5 3 While holding the end of the paper roll close the paper cover See Figure 5 You will hear the paper cover click when properly latched See Figure 4 4 Tear off the excess paper Attaching the Stylus Paper Roll Use the following procedure to attach the Stylus to the ICE 5500Plus 1 Peel the paper backing from the Stylus holder See Figure 6 Figure 6 2 Press the Stylus holder on the desired position Hypercom recommends placing the Stylus on the side of the paper holder or on the body of the terminal See Figure 7 Note Only use the provided Stylus on the screen display Cleaning the ICE 5500Plus Use the following procedure to clean the casing and the printer mechanism of the ICE 5500 Plus A WARNING DO NOT use undiluted ammonia or abrasive cleaners Apply denatured alcohol or a Windex type product to a clean soft non abrasive low lint cloth Carefully wipe the entire terminal including the touch screen and keypad Paper Backing f Figure 7 As needed use anti
2. 24 VDC power cable from the AC adapter to the three pin terminal power socket on the back panel of the ICE 5500Plus See Figure 1 2 Plug the adapter into a grounded AC power outlet Be sure the connector is firmly seated When the power is properly connected the terminal beeps twice then performs a self test routine Connecting the Telephone Line eae igure Use the following procedure to connect a telephone line to the ICE 5500Plus 1 Insert the telephone cable shipped with the ICE 5500Plus terminal into a dedicated analog telephone outlet WARNING DO NOT insert the telephone line into the PIN pad port 2 Insert the other end of the telephone cable into the port labeled LINE on the back panel of the ICE 5500Plus terminal and make sure it is fully seated PIN See Figure 2 The use of a different cable may result in improper operation Note Ensure that the telephone line cable latches are firmly locked into the jacks on both the ICE 5500Plus terminal and wall receptacle Figure 3 Installing an Optional Line Splitter If connection to an extension telephone is needed use the following procedure to install a Hypercom Line Splitter Note The terminal disconnects the PHONE port when a transaction is being processed 1 Insert the Line Splitter into the terminal port labeled LINE See Figure 2 2 Insert the line from the extension phone into the port labeled PHONE Figure 4 on the Line Splitter See Figure 3
3. Value to Innovation World Headquarters 2851 West Kathleen Road Phoenix AZ 85053 602 504 5000 877 HYPERCOM within USA Fax 602 504 5166 e mail info hypercom com web www hypercom com Hypercom Corporation 2002 Printed in the United States of America 940318 002 Rev D 09 02 ICE 5500Pilus TERMINAL INSTALLATION GUIDE
4. ICE 5500Plus Terminal The Hypercom epic ePOS infocommerce ICE 5500Plus combines the flexibility of a full featured smart card ready HyperSmart integrated POS terminal with the infrastructure to quickly and cost effectively integrate new applications This combination makes ICE Interactive Consumer Enviroment the simplest and most innovative POS solution available today The ICE 5500Plus incorporates the new integrated modem technology Hypercom FastPOS Operating at 9600 bps FastPOS allows for lower transaction costs new data rich applications such as signature capture and faster transactions Installation Procedures Note The following equipment warnings are for your safety and that of your equipment WARNING Do not use an ungrounded adapter power adapter power extender cable or AC outlet Do not disassemble the AC adapter Only qualified technicians may service the adapter The AC adapter is intended for indoor use only do not expose to rain or snow Do not immerse in fluid The reliability of this equipment is significantly reduced when it is powered from an ungrounded AC power outlet Ensure that the telephone line is disconnected when the unit is unplugged from the AC power outlet Do not use a pen on the screen display Pens and other sharp objects will scratch or damage the screen display Powering Up the Terminal Figure 1 Use the following procedure to power up the ICE 5500Plus 1 Connect the
5. static compressed air to clean in and around the printer mechanism Paper Holder Stylus Holder Using a Credit Card A credit card can be swiped bi directionally either toward or away from you 1 When holding the card make sure the magnetic stripe is toward the body of the terminal toward your left and down 2 Slide the card in the long slot on the right side of the terminal starting on either end in one smooth stroke See Figure 8 3 Follow standard operating procedures to complete the transaction Figure 8 i See the ICE 5500Plus HyperWare Retail and Restaurant Software Manual for more information or contact your bank or processor Using a Smart Card Optional Use the following procedure to insert a Smart Card 1 When holding the card make sure the metallic contact is facing upward and toward the body of the terminal Smart Card Slot 2 Insert the card into the Smart Card slot on the right side of the ICE 5500Plus See Figure 8 Remove the Smart Card when the terminal screen instructs you to do so Credit Card Slot Supply Information If you are unable to purchase items such as paper through your bank or processor contact Merchant Supplies at 800 522 8710 Compliance This equipment is compliant with one or more of the following e FCC Part 15 ICES 003 EN60950 e FCC Part 68 CS 03 e CISPR 22 e CTR21 e AS NZS 3260 EN55022 e AS NZS 3548 EN55024 lt HYPERCOM gt Adding