Home
Hunter CF652BQ01 User's Manual
Contents
1. Pull Chain Ball Chain Coupling Owners Manual BP7316 BP7316 BP7316 BP7316 BP7316 BP7316 BP7316 IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Repair Parts Listing 1 1 1 2 6 6 6 6 4 5 6 3 7 6 6 6 6 6 Part No F40BP73160000 U L Model No CF652 Printed in China 09 07 Form No BP7316 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 Maintenance Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136
2. Safety Instructions 1 Read your owner s manual carefully and keep it for future reference 2 Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 3 Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing 4 Do not put anything into the fan blades while they are turning 5 Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation 1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring must be in accordance with the National Electrical Codes ANSI NFPA 70 1999 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 50 lbs or less and use the mounting screws provided with the outlet box Most
3. turn your fan off and wait for the blades to stop turning then slide the reversing switch to opposite position and turn fan on again The fan blades will turn the opposite direction and reverse the airflow Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows 7 U L Model No CF652 Trouble Shooting WARNING FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1 Fan will not start 1 Reversing switch in neutral position 1 Make sure reversing switch position is all the way to one side 2 Fuse or circuit breaker blown 2 Check main and branch circuit fuses or circuit breakers 3 Loose power line connections to the fan or loose 3 Check line wire connections to fan and switch wire switch wire connections in the switch housing connections in switch housing 2 Fan sounds 1 Blades not attached to fan 1 Attach blades to fan before operating noisy 2 Screws securing fan blade flanges to motor 2 Check to make sure the screws which attach the fan blade are loose flanges to the motor are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing 4 Screws holding flanges to blades are loose 4 Tighten screws securely 3 Fa
4. is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING NOTE If you are using an Emerson light fixture with your fan remove the three screws securing the switch housing cover to the switch housing and remove the cover Remove the screw plug from the bottom of the switch housing cover and install the light in accordance with the light kit Owner s Manual 2 Connect the fan motor white wire to the supply white neutral wire using a wire connector supplied Figure 7 Connect the fan motor black wire and blue wire to the supply black hot wire using a wire connector supplied Figure 7 Your fan is now wired to be turned on and off from the fan switch After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through
5. holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three mounting screws Figure 5 NOTE Do not pinch wires between the switch housing assembly and the switch housing plate SWITCH HOUSING PLATE MOTOR HUB PREASSEMBLED M6 x 14 FLANGE SCREWS WITH LOCKWASHERS 2 BLADE FLANGE 4 Reinstall the two setscrews in the motor coupling While pulling up on the hanger ball securely tighten the setscrews Figure 1 NOTE The setscrews must be properly installed as described above or fan wobble could result 5 The fan comes with blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads IMPORTANT THE SIDE OF THE FAN BLADE HAVING THE RIB LINE MUST BE FACING UPWARDS AS SHOWN IN FIGURE 2 6 Mount blade flanges to fan blades using three M5 x 6 washer head screws per blade Figure 2 NOTE Remove and discard the five shipping spacers and screws from the motor hub 7 Turn the fan assembly upside down in preparation for mounting the fan blade assemblies FAN BLADE BLADE FLANGE 3 16 24 x 5 16 SLOTTED PHILLIPS WASHER HEAD SCREW 3 RIB LINE THIS SIDE UP Figure 2 Figure 3 4 U L Model No CF652 CEILING COVER CLEVIS PIN HAIRPIN CLIP CLEVIS PIN HANGER BALL DO
6. or property damage The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device WARNING SPEED CONTROL SWITCH REVERSIBLE SWITCH THREE SPEED 1st Pull High 2nd Pull Medium 3rd Pull Low 4th Pull Off Service Part No Key 52 Model No Description CF652WW01 CF652BQ01 CF652SCB01 CF652AW01 CF652WB01 CF652CK01 CF652ORB01 1 Hanger Assembly 760750 3 760750 40 760750 36 760750 41 760750 39 760750 43 760750 48 2 Ceiling Canopy 760169 760169 31 760169 24 760169 32 760169 30 760169 34 760169 41 3 Wiring Harness 762569 6 762569 5 762569 5 762569 6 762569 5 762569 6 762569 5 4 Blade Set 5 762445 6 762445 3 762445 4 762445 5 762445 3 762445 1 762445 2 5 Flange Set 5 762898 WW 762898 BQ 762898 SCB 762898 AW 762898 WB 762898 CK 762898 ORB 7 Housing Switch Cup 761935 761935 10 761935 4 761935 13 761935 14 761935 15 761935 17 6 Loose Parts Bag 763118 1 763118 763118 763118 2 763118 763118 1 763118 Containing Blade Hardware Hanging Hardware Threaded Stud 2 Lockwasher 2 Knurled Knob 2
7. outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future us
8. parts a Fan motor assembly b Five fan blades c One ceiling cover d Five blade flanges e One hanger ball downrod assembly f One hanger bracket g One switch housing assembly h One loose parts bag containing 1 Sixteen M5 x 6 washer head blade screws 2 One M6 x 14 flange screw with lockwasher 3 One wood ball 4 Three wire connectors 5 One clevis pin 6 One hairpin clip 7 Two threaded studs 8 Two lockwashers 9 Two knurled knobs 10 One chain coupling NOTE Place the parts from the loose parts bag in a small container to keep them from being lost Unpacking Instructions For your convenience check off boxes are provided next to each assembly step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted How to Put Your Ceiling Fan Together Before assembly your ceiling fan refer to section on proper method of wiring your fan page 5 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only tho
9. the holes in the ceiling cover Figure 10 5 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 10 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch 6 Cut the 3 speed switch pull chain to a desired length optional Connect the wood pendant supplied to the 3 speed switch pull chain by sliding the wooden pendant small hole first onto the pull chain Attach the chain coupler to the end of the chain and allow the wooden pendant to fall down over the coupling CEILING COVER THREADED STUD KNURLED KNOB LOCKWASHERS 2 Figure 10 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the pull chain switch 3 All fans are shipped from the factory with the reversing switch positioned to circulate air downward If airflow is desired in opposite direction To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device WARNING
10. Part No F40BP73160000 Form No BP7316 U L Model No CF652 READ AND SAVE THESE INSTRUCTIONS Model No CF652AW01 CF652ORB01 CF652BQ01 CF652WB01 CF652CK01 CF652WW01 CF652SCB01 SUMMER NIGHT 52 Damp Location Ceiling Fan Owner s Manual Net Weight 16 5 Lbs LIMITED WARRANTY What The Warranty Covers This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is As it applies to the motor this warranty will last for thirty years from the date you purchased your ceiling fan All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Electric Co Do To Correct Problems Emerson Electric Co will replace a defective Emerson Air Comfort Ceiling Fan motor blade component or other accessory at no charge to you If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided Emerson will refund the actual purchase price of your fan We will ship the repaired product or replacement to you at no charge but you are responsible for all costs or removal r
11. WNROD ASSEMBLY SETSCREW MOTOR COUPLING SETSCREW Figure 1 To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING SWITCH HOUSING ASSEMBLY SWITCH HOUSING CONNECTOR MOTOR CONNECTOR SWITCH HOUSING MOUNTING SCREW Figure 4 M5 x 6 WASHER HEAD SCREW 3 12 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan MOUNTING SCREWS 3 SWITCH HOUSING ASSEMBLY Figure 5 Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Electrical Requirements To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electr
12. e Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow Consult your Emerson Retailer for optional mounting accessories Using the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that Energy Efficient Use of Ceiling Fans provides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy 1 Pass the 80 motor leads through the opening in the ceiling cover Be sure the cover is oriented correctly Figure 1 2 Separate
13. e including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when The original purchaser or user ceases to own the product or The fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state ENERGY STAR 2 U L Model No CF652 WARNING To avoid fire shock and serious personal injury follow these instructions
14. einstallation and shipping of the product to Emerson Electric Co How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Electric Co 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your ceiling fan while in your possession or Unreasonable use misuse abus
15. icity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 6 WARNING 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 7 AT LEAST 7 CEILING FLOOR Figure 6 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 7 2 Carefully lift the fan from the foam pad and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 8 Be sure the groove in the ball engages with the tab on the hanger bracket Figure 7 To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The outlet box and joist must be securely anchored and capable of
16. n wobbles 1 Setscrews in motor coupling is loose 1 Tighten the setscrews securely in the motor coupling or shakes 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod excessively loose assembly 3 Screws securing fan blade flanges to motor 3 Check to be sure screws which attach the fan blade are loose flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 6 Fan blades out of balance 6 Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation Accessories 1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury
17. se parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING WARNING WARNING WARNING 8 Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate Attach one blade assembly to the motor hub using two M6 x 14 flange screws with lockwashers preassembled in flange Make sure the screws are NOT tightened Figure 3 Repeat this procedure for the other four blade assemblies 9 The blade flanges have an interlocking feature that must be fully engaged before tightening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again 10 Engage the connector of the switch housing assembly with the motor connector Figure 4 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 11 Remove the three switch housing mounting screws Figure 4 from the switch housing plate Position the switch housing assembly on the switch housing plate and align the
18. supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING 5 U L Model No CF652 OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY Figure 8 NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation GROUND WIRE WIRE CONNECTORS 3 GREEN WIRE GROUND FROM FAN WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 9 NOTE CEILING COVER OMITTED FOR CLARITY 6 U L Model No CF652 To avoid possible electrical shock be sure electricity
19. untwist and unkink the three motor leads Route the motor leads through the hanger ball downrod assembly 3 Remove the two setscrews from the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 1 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed Tools Needed for Assembly One Phillips head screwdriver One stepladder One wire stripper Three wire connectors supplied MATERIALS Wiring electrical box and box connectors must be of type required by the local code The minimum wiring would be a 3 conductor 2 wire with ground of following sizes Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 THIS FAN IS SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES COVERED PATIOS AND COVERED DECKS ANYWHERE THERE IS A ROOF OVERHEAD This Manual is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan 3 U L Model No CF652 Check to see that you have received the following
Download Pdf Manuals
Related Search
Related Contents
SP: manual técnico do pré natal e puerpério dichiara - Policlinico Brother PT2030AD User's Manual Kocioł ścienny gazowy o wysokiej sprawności Plynové FINAL REPORT: AN OPEN SOURCE 6DOF ROBOTIC ARM descargar ficha técnica Copyright © All rights reserved.
Failed to retrieve file