Home
Hunter ASHBURY 81003 User's Manual
Contents
1. Secure the motor by tightening the 2 screws A21 Go to step ON G IA OFF on page 10 to attach grille Test the motor If the motor does not run check the plug connection 41937 01 10 26 2010 Existing Construction EXISTING FAN Remove an existing fan and check to make sure the Move the housing into position above the ceiling opening is large enough to accommodate the new motor housing 7 1 4 x 7 3 4 Route wires through the strain relief For supply connec Attach existing ducting to duct connector Tape joints tion use wires suitable for at least 90 C 194 F If ducting does not fit securely an adapter may need to be purchased Install the housing flush with the sheetrock and secure by tightening the pre loaded screws into the joist 41937 01 10 26 2010 Ground J Green D Bare Copper Black Main Switch 1 AC In XAN Black Switch 2 AC In Connect wires as shown Install the wiring cover plate Connect wiring harness DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS B 52U a ae Reinstall the motor by inserting the tabs and pushing Secure the motor by tightening the 2 screws up into position Make sure the wires are not pinched between the motor and the housing 9 41937 01 10 26 2010 B22 ON Q OF
2. Back out the pre loaded screw tips until flush with the side of the housing Remove the wiring cover 41937 01 10 26 2010 Pop out the first wiring access slug Use second if needed Insert the strain relief not included into the housing and secure with washer Choose Installation Option For New Construction go to step A11 page 5 For Existing Construction go to step B11 page 8 New Construction 3 0 TOO Aa ye Position the correct depth mark at the bottom edge of the Screw pre loaded screws into joist or framing joist based on the thickness of your sheetrock 41937 01 10 26 2010 Route wires through the strain relief For supply connection use wires suitable for at least 90 C 194 F Ground Green Bare Copper Fan Motor Black Main Switch 1 AC In Black Light Black Switch 2 AC In Connect wires as shown Install the wiring cover plate Make sure all Connect 4 duct and vent to the outside Tape joints wiring connections are inside the box or under If ducting does not fit securely an adapter may need to be purchased the wiring cover plate 6 41937 01 10 26 2010 ga Connect wiring harness DO NOT ALLOW THE MOTOR TO Reinstall the motor by inserting the tabs and pushing up HANG FROM THE WIRING HARNESS into position Make sure the wires are not pinched between the motor and the housing
3. A sh buny Bath Ventilator with Light TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in a manner intended by the manufacturer Engineers ASHRAE and the local code authorities If you have questions contact the manufacturer When cutting or drilling into wall s or ceiling do not damage Before servicing or cleaning the unit switch power off at ser electrical wiring or other hidden utilities vice panel and lock the service disconnecting means to prevent Ducted fans must always be vented to the outdoors power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 7 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit Installation work and electrical wiring must be done by quali fied person s in accordance with all applicable codes and standards including fire rated construction Never place a switch where it can be reached from a tub or shower 9 Install fan at least 5 feet 1 52 m above the floor Sufficient air is needed for proper combustion and exhausting eg of gasses through the flue chimney of fuel burning equipment 10 This unit must be grounded to prevent backdra
4. Turn on the power source Test the motor If the motor does not run check the plug connection Go to step Q on page 10 to attach grille Attaching the Grille i ec Sct i Se apt hi Totnes ews L H Pg r NAi Pee S gt o Remove the thumbscrews Remove glass dome 41937 01 10 26 2010 Connect wiring harness DO NOT ALLOW THE FIXTURE Remove the strain relief bracket screw TO HANG FROM THE WIRING HARNESS Position the strain relief bracket under the Insert the strain relief bracket s dog leg tab so that motor as shown it hooks over the lip of the motor Reinstall the strain relief bracket screw 6 Sy LII SE a 8 D Align posts 1 2 and 3 stamped into motor housing with Attach thumbscrews posts 1 2 and 3 stamped into light fixture Slide light WARNING To reduce the risk of electrical shock fixture over posts all 3 thumbscrews MUST be properly installed 41937 01 10 26 2010 Install 2 Max 60 Watt A15 bulbs Not Included Screw glass dome into position 41937 01 10 26 2010 Align glass dome and push up Trouble Shooting Problem Fan does not come on Solution e Hunter Fan Bath Ventilators are extremely quiet To confirm that the fan is running place your hand near the vents to feel the air movement e Turn power on replace fuse or reset
5. breaker e Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Light does not come on Solution e Replace the light bulb with a new bulb e Turn power on replace fuse or reset breaker e Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Fan is noisy Solution e Check and tighten all fasteners e Check the glass to make sure it is secure e Check the flapper to make sure it moves freely If you need parts or service assistance please call 888 830 1326 or visit us at our WEB site at http Awww hunterfan com 41937 01 10 26 2010 Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan If any part of your Hunter bath exhaust fan except for glass fixtures and light bulbs fails at any time within one year after the date of sale to you due to a defect in material or workmanship we will repair or at our option replace the defective part free of charge for parts and labor performed at our nearest service center or at our Service Department in Memphis Tennessee After this one year period you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as provided below If your Hunter bath exhaust fan mo
6. MITATION OR EXCLUSIONS MAY NOT APPLY TO YOU THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE 7130 Goodlett Farms Pkwy Suite 400 Memphis Tennessee 38016 Printed in China 41937 01 10 26 2010 2010 Hunter Fan Company
7. an is not purchased and installed in the U S A This warranty excludes and does not cover defects malfunctions or failures of any Hunter bath exhaust fan which were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling improper installation modifications or damage to the Hunter bath exhaust fan while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance To obtain servicing contact the nearest Hunter authorized service center of the Hunter Fan Company Service Department 7130 Goodlett Farms Pkwy Suite 400 Memphis Tennessee 38016 Please contact us before shipping your bath exhaust fan to us If we authorize you to ship it to us you will be responsible for all insurance and freight or other transportation charges to our factory or service center We will return your Hunter bath exhaust fan freight prepaid Your Hunter bath exhaust fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Proof of purchase is required when requesting warranty service The purchaser must present the sales receipt or other document that establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LI
8. e located next to the receptacle Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing next to tab and twist screwdriver Gently vacuum fan motor and interior of housing METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER MAINTENANCE Cooking The motor is permanently lubricated and never needs oiling If the Equipment motor bearings are making excessive or unusual noises replace the motor with the exact service motor You should replace the impeller at the same time 41937 01 10 26 2010 COOKING AREA Check all the parts gt 95047 03 000 If damaged call 1 888 830 1326 gt 77481 01 000 gt 03242 07 133 gt 95261 02 000 gt 74508 03 133 x2 gt 71522 01 for replacements D gt 65219 96397 01 214 for model 81001 96397 02 444 for model 81003 x2 gt D pea NOTE Strain relief cable gt 86812 01 000 connector must be installed Not Included 75733 01 214 for model 81001 75733 01 444 for model 81003 Included Tools Needed Not supplied Estimated assembly time 30 to 60 minutes Before Installation NOTE Remove all packing materials before installation EZ G C U Se Ci Turn off the power source Loosen screws 41937 01 10 26 2010 Remove the wiring cover screw
9. fting Follow the heating equipment manufac 11 Unit must not be installed in a ceiling thermally insulated to a turer s guideline and safety standards such as those published value greater than R40 by the National Fire Prevention Association NFPA and the 12 For supply connection use wires suitable for at least American Society for Heating Refrigeration and Air Conditioning 90 C 194 F ACAUTION AWARNING For general ventilating use only Do not use to exhaust hazard ous or explosive materials and vapors D S C O N N ECT E L ECT RI C To avoid motor bearing damage and noisy unbalanced impellers POWE R S U P P LY keep drywall spray construction dust etc off power unit DO NOT install this product in a wall This product is designed AN D LOC K OUT for installation in ceilings up to a 12 12 pitch 45 degrees S E RVI C E PAN E L B E FO RE Ductwork must point upward Please read specification label on product for further information S E RVI C l N G U N IT and requirements PREVENTATIVE MAINTENANCE A clean fan provides better service Disconnect the power supply and clean the fan as listed below TO CLEAN GRILLE Use a mild detergent such as dishwashing Do Not Install Above liquid and a soft cloth DO NOT use abrasive cloths steel wool pads Or Inside This Area or scouring powders TO CLEAN FAN ASSEMBLY Unplug motor cord from receptacle To remove motor plate find the single tab on the motor plat
10. tor fails at any time within five years after the date of sale to you due to a defect in material or workmanship labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service Department in Memphis Tennessee If no replacement part can be provided we will at our option either refund the actual purchase price of your bath exhaust fan or provide a replacement free of charge After this five year period you will be responsible for all parts and labor costs for repairs on all parts of the bath exhaust fan IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTORS OR OTHER PARTS This warranty is voided if your Hunter bath exhaust f