Home

Hunter 41554-01 User's Manual

image

Contents

1. location Service Parts To obtain a service part for your humidifier call customer service at 1 800 322 4707 or e mail us customerservice charleysgreenhouse com Please be prepared to tell the operator the model number of your humidifier and the name of the part you need to replace and the part number Refer to Figure 1 for part names Filter Model No 64171 01 000 33203 Frame 92849 01 325 33252 33280A So 64171 01 001 TON 64171 01 000 37203 Ras 67171 01 001 92849 01 325 92851 01 326 _ orzo a E 37352 41554 01 7 12 2002 33203 _ 64101 01 325 92851 01 326 Gah Se 30302 64102 01 325 en a 64171 03 000 92850 01 325 92852 01 326 T a 64101 01 325 74079 01 325 a 74080 ce 64171 03 000 92850 01 325 92852 01 326 64102 01 325 ee Hate Perma wick Filter 74082
2. the unit 2 Lift the main housing and remove the wa ter dispersion tray and the PermaWick Filters The motor is attached to the main housing Do not place the motor near water Do not use a wet towel on the motor or motor housing as electrical shock may occur 3 The PermaWick Filter should be cleaned in a vinegar and water solution to remove any mineral buildup Place in a solution of one 1 gallon of water and eight 8 ounces of undiluted white vinegar Allow the filter to soak for 20 minutes 4 After soaking rinse it several times with clean water Place the PermaWick Filter 41554 01 7 12 2002 in a location where it can drip dry while you clean the other parts of your humidifier Remove the water tank from the base and empty any water that is left in the tank Soak the base in a mixture of one 1 gal lon of water and eight 8 ounces of vin egar for 20 minutes After soaking wipe the base with a soft cloth or sponge to remove any mineral build up Rinse with clean water several times If you are planning on storing the humidifier be sure the base is com pletely dry Fill the water tank with one 1 gallon of water and eight ounces of undiluted white vinegar Replace the tank cap and shake the tank vigorously until all interior sur faces of the tank have been exposed to the water vinegar mixture Empty the tank of the water vinegar mix ture Rinse it several times with clean water and
3. 01 7 12 2002 Desired Humidity Control Figure 3 Using Your Humidifier Remove The Care Free Humidifier Plus Evaporative Humidifier from its packaging Read and Save the Instructions Place the humidifier on a hard flat water resistant surface Always place the humidi fier at least six 6 inches away from walls and sources of heat Lift the main housing to confirm that the PermaWick filters are placed upright in the slots Replace the main housing See Figure 1 Remove the water tank and take it to the sink or tub to fill Turn the tank upside down and unscrew the tank cap by turning it counterclockwise Fill the water tank with cool water and replace the tank cap Never use hot water Be sure not to overfill the tank as water damage may occur to furniture or flooring due to spillage HUNTER WILLNOT ACCEPT RESPONSIBILITY FOR DAMAGE TO PROPERTY CAUSED BY WATER SPILLAGE Carry the tank back to the humidifier Turn the tank upright and place it on the humidi fier Be sure that the tank is seated properly in the base If the tank is properly located on the base you will see air bubbles flowing up into the tank With the power control knob in the OFF po sition plug the humidifier into the wall CAUTION Never plug in the Humidifier while your hands are wet as Electric Shock could occur Use the power control knob to turn the humidifier ON by selecting a speed set ting 41554 01 7
4. 12 2002 Only for models with an Adjustable Humi distat 9 You can choose the desired humidity out put by adjusting the Adjustable Humidis tat knob In a very dry room the i Hli setting should be used to quickly achieve a comfortable level of humidity Once the room is comfortable you can turn the Adjustable Humidistat down Selection of your desired humidity level is a per sonal choice and you may have to adjust the dial to find the level where you feel most comfortable To begin with we sug gest you try a middle location between the lowest and the maximum setting Then adjust the level to suit your needs 10 When the humidity reaches the level you have set the Desired Humidity light will be illuminated The humidifier will not output humidity while the humidity in the room is at the selected humidity level The Desired Humidity light will stay on un til the humidity changes When the hu midity in the room drops below the se lected level the humidifier will cycle on again and the i Desired Humidityi light will go off Only for models with Automatic Shut off 11 When the water tank is empty the humidi fier will automatically shut itself off The red light will be illuminated indicating that the water tank needs to be refilled 12 Follow REFILLING THE WATER TANK di rections Once the water tank is refilled the Refill Light will not be illuminated Only for models witha NiteGlo Night Light 13 Use the c
5. T he Care Free Humidifier Plus Evaporative Humidifier Features V ary By Model NiteGlo d Night Light A djustable H umidistat A utomatic Shut Off Refilling T he Water Tank 1 When the water tank level is low turn the humidifier OFF and unplug 2 Remove the tank and take it to the sink or tub to refill 3 Turn the tank upside down and unscrew the tank cap by turning it counterclockwise Empty the tank refill with fresh cool water never use hot water and replace the tank cap Be sure not to overfill the tank as water damage may occur to furniture or flooring due to spillage HUNTER WILL NOT ACCEPT RESPONSIBIL ITY FOR DAMAGE TO PROPERTY CAUSED BY WATER SPILLAGE Carry the tank back to the humidifier Turn the tank upright and place it on the hu midifier Be sure that the tank is seated properly in the base If the tank is properly located on the base you will see air bubbles flowing up into the tank Cleaning T he Humidifier And T he Water Tank Many regions have hard water with high concentrations of minerals When water evaporates from The Care Free Humidifier Plus Evaporative Humidifier minerals may be left behind These minerals can form a hard white scale which can be removed by following the cleaning instructions The frequency of cleaning due to mineral build up can vary depending upon the quality of water you may have Refer to Figure 1 for part names 1 Turn the humidifier OFF and unplug
6. en light will be illuminated when the humidity in the room has reached the level that you selected with the adjustable humidistat knob Power Speed Control Turns the humidifier ON and OFF The power should always be off before unplugging the humidifier moving the humidifier or refilling the water tank Refill Light The red light will be illuminated to signal you that the humidifier has automatically turned off and the water tank needs to be refilled 41554 01 7 12 2002 Adjustable Desired Humidity Light Speed Control Figure 5 For Models 34302 34352 37302 amp 37352 Adjustable Humidistat Enables you to set a desired maximum humidity level Once this level is reached the unit will shut off until the humidity level drops Note The humidifier may not be running because the humidistat setting may need to be adjusted Desired Humidity Light The green light will be illuminated when the humidity in the room has reached the level that you selected with the adjustable humidistat knob Power Speed Control Turns the humidifier ON and OFF The power should always be off before unplugging the humidifier moving the humidifier or refilling the water tank Refill Light The red light will be illuminated to signal you that the humidifier has automatically turned off and the water tank needs to be refilled NiteGlo6 d Night Light Control Turns the night light ON and OFF The night light can be turned on eve
7. n if the humidifier fan is turned off 41554 01 7 12 2002 Desired Humidity Light Figure 6 Refill Light Power Speed Control NiteGlo Night Light Control READANDSAVETHESEINSTRUCTIONS Important Safety Instructions Read all instructions before using this humidifier This humidifier may not work properly on an uneven surface ALWAYS place this humidifier on a firm level and wa ter resistant surface ALWAYS place the humidifier at least six 6 inches away from walls and heat sources such as stoves radiators or heaters ALWAYS place the humidifier in an area that is out of the reach of children Before using the humidifier extend the cord and inspect for any signs of dam age DO NOT use the product if the cord has been damaged This product has a polarized plug one blade is wider than the other as a safety feature This plug will fit into a polarized outlet only one way If the plug does not fit fully into the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to defeat or override this safety feature ALWAYS UNPLUG AND EMPTY the hu midifier when it is not in operation or while it is being cleaned DO NOT tilt or move the humidifier while it is in operation Never move the hu midifier while there is water in the tank Empty the water tank turn off and un plug the unit before moving In addition to routine main
8. ontrol to turn the night light off and on The night light can be operated even if the humidifier fan is turned OFF For Models 33203 33252 33282 34332 37203 amp 37252 Adjustable Humidistat Enables you to set a desired maximum humidity level Once this level is reached the unit will shut off until the humidity level drops Note The humidifier may not be running because the humidistat setting may need to be adjusted Desired Humidity Light The green light will be illuminated when the humidity in the room has reached the level that you selected with the adjustable humidistat knob Power Speed Control Turns the humidifier ON and OFFi The power should always be off before unplugging the humidifier moving the humidifier or refilling the water tank Power Light The light will be illuminated when the power is on NiteGlo6 d Night Light Control Turns the night light ON and OFF The night light can be turned on even if the humidifier fan is turned off Desired Humidity Power Light Light Adjustable Power Humidistat Speed Control NiteGlo Night Light Control Figure 4 For Models 34301 34351 37301 amp 37351 Adjustable Humidistat Enables you to set a desired maximum humidity level Once this level is reached the unit will shut off until the humidity level drops Note The humidifier may not be running because the humidistat setting may need to be adjusted Desired Humidity Light The gre
9. tenance which may be required this humidifier requires seasonal cleaning Refer to and follow CLEANING THE HUMIDIFIER AND THE WATER TANK instructions Thank you for purchasing The Care Free Humidifier Plus Evaporative Humidifier by Hunter Fan Company Please read and save these instructions to receive the maxi mum benefit and performance from your humidifier How The Care Free Humidifier Plus Evaporative Humidifier Works The Care Free Humidifier Plus Evaporative Humidifier has a unique patented design with several innovative features Low Maintenance Other humidifiers have paper filters that need to be replaced every few months Our exclusive PermaWicki fil ter saves time and money Itis designed to last season after season saving up to 45 a year No wet paper odors either Regulated Release System By dis persing water from the top of the PermaWick filter stagnant water around the PermaWick filter is eliminated and the buildup of mineral residue that can clog the filter and impede performance is eliminated NOTE The filter has a coat 41554 01 7 12 2002 ing on the wick which may make it appear old or used but is actually new Built in Antimicrobial Properties The plastic parts and the PermaWick filter have built in antimicrobial properties to in hibit the growth of bacteria mold and fungi that may affect these parts NOTE This product contains antimicrobial properties which are built in to inhibit
10. the growth of bacteria which may affect the plastic and PermaWick filter in the hu midifier These properties do not extend to the water humidified air or users Conduct routine cleaning and maintenance based upon use and individual conditions No White Dust The Care Free Humidi fier Plus Evaporative Humidifier produces no white dust that can settle on furniture or be inhaled NOTE You may notice mineral deposits accumulating in the tank base or on the PermaWick filter This is normal and does not affect performance If you would like to clean these deposits away please see CLEANING THE HUMIDIFIER AND WATER TANK Humidifier Parts Filter Frame Hooks wl Nis gt SSRIS SSR RRS ASS PENN xtc GTN PermaWick6 Filter PermaWick Filter Frame Insert Guides Into Base Figure 1 41554 01 7 12 2002 Easy Tote Handle Water Tank Tank Cap Main Housing 10 water residue soak it in a mixture of one 1 gallon of water and eight 8 ounces of vinegar for 20 minutes Rinse well and reinstall sponge and diffuser cap in unit Do not expose motor or other electrical components to water Wipe the surfaces of the main housing with a soft cloth 11 Once all the parts are clean reas semble the humidifier and follow the USING YOUR HUMIDIFIER to con tinue use If you are storing the hu midifier make sure the parts are completely dry reassemble and store in a dry
11. then replace the tank cap If you are planning on storing the humidifier dry it inside and out leaving the cap off to allow the tank to completely dry Continue to clean the other parts of your humidifier Remove the water diffuser cap and sponge Rinse the sponge in clean water to remove any debris If the sponge contains hard H umidifier Features For Models 33200A amp 37200A Fan Power Turns the humidifier ON and OFF The power should always be off before unplugging the humidifier moving the humidifier or refilling the water tank Speed Control Enables you to choose HI or 10 speed Power Light The light will be illuminated when the power is on Power Light Speed Control Power Control Figure 2 For Models 33250A 33280A 34331 amp 37250A Adjustable Humidistat Enables you to set a desired maximum humidity level Once this level is reached the unit will shut off until the humidity level drops Note The humidifier may not be running because the humidistat setting may need to be adjusted Desired Humidity Light The green light will be illuminated when the humidity in the room has reached the level that you selected with the adjustable humidistat knob Power Speed Control Turns the humidifier ON and OFF The power should always be off before unplugging the humidifier moving the humidifier or refilling the water tank Power Light The light will be illuminated when the power is on 41554

Download Pdf Manuals

image

Related Search

Related Contents

AudioSonic Rockblaster  Sinclair SMF-C09AI User's Manual  Istruzioni d’uso  KitchenAid KEYE750V User's Manual  User Manual - Quevo Audio  Benq MP511+ DLP SVGA 2100 ANSI  JAN。ME - ジャノメミシン  RT2 Profiler PCR Array System  User`s Manual    

Copyright © All rights reserved.