Home

HP FSPCI64S User's Manual

image

Contents

1. 16 16 16 17 How to reach us FuturePlus Systems can be reached at FuturePlus Systems Corporation 36 Olde English Road Bedford NH 03110 TEL 603 471 2734 FAX 603 471 2738 Internet 71035 3052 compuserve com WEB www futureplus com FuturePlus Systems is represented in Japan by ANDOR Systems Support Co LTD 15 8 Minami Shinagawa 2 chome Shinagawa ku Tokyo 140 TEL 03 450 8101 FAX 03 450 8410 Contact Mr Takashi Ugajin Outside of Japan FuturePlus Systems is represented world wide by Hewlett Packard Co Please contact your nearest Hewlett Packard sales office Product Warranty Limitation of warranty Exclusive Remedies This FuturePlus Systems product has a warranty against defects in material and workmanship for a period of 1 year from the date of shipment During the warranty period FuturePlus Systems will at its option either replace or repair products proven to be defective For warranty service or repair this product must be returned to the factory For products returned to FuturePlus Systems for warranty service the Buyer shall prepay shipping charges to FuturePlus Systems and FuturePlus Systems shall pay shipping charges to return the product to the Buyer However the Buyer shall pay all shipping charges duties and taxes for products returned to FuturePlus Systems from another country FuturePlus Systems warrants that its software and hardware designated by FuturePlus Systems for use
2. 2 AD62 2 AD63 2 INTA 5 INTB 5 INTC 5 INTD 59 RST 61 CLK 63 AD31 65 AD30 67 AD29 AD28 71 AD27 17 AD26 AD25 AD24 C BE3 AD23 AD22 AD21 AD20 AD19 AD18 AD17 AD16 C BE2 FRAME IRDY TRDY DEVSEL STOP LOCK SDONE PERR SBO SERR A C BE1 AD15 AD14 AD13 AD12 AD11 AD10 18 75 CONS ADO9 137 19 20
3. Us HEWLETT PACKARD Premier a solution FuturePlus Systems Corporation Partner gt LOCAL BUS PCI Scope Preprocessor Users Manual FSPCI64S For Hewlett Packard Logic Analysis Systems Revision 1 0 FuturePlus Systems and PCI Scope is a trademark of FuturePlus Systems Corporation Copyright 1995 FuturePlus Systems Corporation HOW TO REACH US PRODUCT WARRANTY Limitation of warranty Exclusive Remedies Assistance INTRODUCTION How to Use This Manual ANALYZING THE PCI LOCAL BUS Duplicating the Master Diskette Accessories Supplied Minimum Equipment Required Signal Naming Conventions Connecting the 208 pin MultiProbe Pod to the PCI Scope Preprocessor Installing the PCI Scope Preprocessor Setting up the MultiProbe control card for PCI Analysis Connecting the MultiProbe Control Card to an Oscilloscope ANALOG ANALYSIS Installation Quick Reference Selecting the PCI signals to acquire Acquiring signals with an Oscilloscope The PCI Personality Adapter option 101 GENERAL INFORMATION Characteristics Preprocessor Interface Compatibility JTAG Boundary Scan The PCI Present Pins 11 11 12 13 14 15 15 15 15 15 Standards Supported Power Requirements MultiProbe Pods required Signal loading Operations Environmental Temperature Altitude Humidity Testing and Troubleshooting Servicing Signal Connections for the MultiProbe POD 15 15 15 15 16 16 16
4. al load on each PCI bus signal The PCI Scope Preprocessor is designed to present a worst case load 10pf at the maximum stub length For 15 Operations Environmental Temperature Altitude Humidity Testing and Troubleshooting Servicing information on the electrical loading of the MultiProbe Pod refer to your Hewlett Packard MultiProbe specification All PCI Local Bus operations supported Operating 0 to 55 degrees C 32 to 131 degrees F Non operating 40 to 75 degrees C 40 to 167 degrees F Operating 4 6000m 15 000 ft Non operating 15 3000m 50 000 ft Up to 90 non condensing Avoid sudden extreme temperature changes which would cause condensation on the preprocessor module There are no automatic performance tests or adjustments for the PCI Scope Preprocessor module If a failure is suspected in the PCI Scope Preprocessor module contact the factory or your FuturePlus Systems authorized distributor The repair strategy for the PCI Scope Preprocessor is module replacement However if parts of the PCI Scope Preprocessor module are damaged or lost contact the factory for a list of replacement parts 16 The below table shows the connection from the PCI Local Bus to Nils ee the PQFP package that acts as the MultiProbe Contact point or ine Mulurrope POD If the pin is not listed it is Grounded PCI Signal PQFP pin AD50 AD51 AD52 AD53 AD54 AD55 AD56 AD57 15 AD58 17 AD59 19 AD60 2 AD61
5. g Analysis Since the PCI Scope Preprocessor interface contains only passive matching terminators it introduces negligible skew to the PCI Local Bus signals Installation Quick The following procedure describes the major steps required to perform analog analysis measurements with the PCI Scope Reference Preprocessor module 1 Install the PCI Scope Preprocessor module into a slot in the target PCI Local bus 2 Load the PCI MultiProbe configuration file PCI_MUL DUT from the MULTIPRB directory on the hard disk See page 9 for details on how to load this file Once the file is loaded the POD that is connected to the PCI Scope Preprocessor will be assigned the name PCI LogicScope as shown below MultiProbe E Configuration Pod 1 PCI LogicScope Pod 2 Not Connected Pod Assign Setup Signal Names Rear View Rear View Pod 3 Not Connected Pod 4 Not Connected Rear View Rear View 11 Selecting the PCI signals to acquire Select the oscilloscope for each MultiProbe output using the Select Signals menu of the MultiProbe control module 1 Access the Select Signals menu 2 Select the scope for each output a Choose the output Output 1 or Output 2 of the control module that is connected to the pod that is attached to the PCI Scope Preprocessor In the Select Signal menu select the Output field to choose Output 1 or Output 2 of the control module For example Output D1 would be output 1 from the control module in sl
6. n Selected Signal Pod Pin Signal Name Pin MORE 32 1 28 INTB 1 29 INTC 1 30 INTD Find Signal Name A RE 1 33 AD31 CLK 1 34 AD3O 1 1 Input Range Probe Attenuation Factor 27 04 3 to 48 V Using an HP16534A oscilloscope If you are using an HP 165344 oscilloscope then follow this procedure 1 Access the oscilloscope menus To view your measurements with an HP16534A oscilloscope you need to exit the MultiProbe Control menus then enter the oscilloscope menus Select the MultiProbe field then select the oscilloscope module 2 Use the oscilloscope controls to run and adjust the measurement If you need help refer to the documentation on your oscilloscope 3 Select new signals You can select signals from the oscilloscope Select Signals field the oscilloscope Scroll Signal field or the MultiProbe Select Signal menu Selecting signals from the oscilloscope menus is possible only with the HP16534A Oscilloscope A scope picture taken with the PCI Scope Preprocessor of a glitch with FRAME and the PCI clock appears below 13 Center Screen Tx to To Trig to X MTrig to o 1 00 ns 35 90 ns 34 90 ns The PCI Personality When the PCI Personality Adapter 101 is not in use keep it in i its original container The file PCI ADP matches the Adapter option 101 configuration of the PCI Personality Adapter and configures the MultiProbe for PCI Analysis If you wish to configure your own Pe
7. ot D b Select the scope that you will use In the Select Signal menu select the scope field then choose the scope You are selecting the scope that is connected to the outputs that you chose in the previous step 3 Select the PCI signal for each output a Access the menu If you are using an HP1634A Oscilloscope you can select signals in either the MultiProbe menu or the Scope menu Using the Scope menu means that you do not need to change back to the MultiProbe menu every time you want to choose a different signal If you are using any other scope access the MultiProbe Select Signal menu b Select the signals in one of the following ways e Choose the PCI LogicScope Pod and the pin number of the PCI signal that you wish to see Select the Pin Field then use the keypad e Choose the PCI LogicScope Pod and pin number of the PCI signal With the Pin field highlighted use the knob HP16500B mainframe only to scroll through the Selected Signal list e Go directly to a signal name Select the Find Signal Name field use the keypad to insert the signal name then select Done to close the keypad Select Find Next The below picture shows the Select Signal menu after loading the PCI_MUL file into the MultiProbe Control module 12 Acquiring signals with an Oscilloscope MultiProbe E Select signal for output El a ida 35 AD29 36 AD25 Find Next MORE Pod 1 PCI Local Bus Select Pod and Pi
8. p prevent the possibility of losing or destroying the original files in the event the diskette wears out is damaged or a file is accidentally deleted To make a duplicate copy use the Duplicate Diskette operation in the disk menu of your logic analyzer For more information refer to the reference manual for the HP16500B mainframe The PCI Scope Preprocessor product consists of the following accessories e The PCI Scope interface hardware which includes the interface circuit module e The MultiProbe configuration software on a 3 5 inch diskette e This operating manual The minimum equipment required for complete analysis of a PCI Local Bus consists of the following equipment e An HP16500B based Logic Analyzer e An HP 16535A MultiProbe Control Module e A208 pin MultiProbe Pod HP part number E5322A 8 Signal Naming Conventions Connecting the 208 pin MultiProbe Pod to the PCI Scope Preprocessor Installing the PCI Scope Preprocessor Setting up the MultiProbe control card for PCI Analysis e An Oscilloscope e The PCI Scope Preprocessor Product e A PCI target bus This operating manual uses the same signal notation as the PCI LOCAL BUS SPECIFICATION REVISION 2 1 That is a symbol at the end of a signal name indicates that the signal s active state occurs when it is at a low voltage The absence of a symbol indicates that the signal is active at a high voltage To use the MultiProbe Pod two steps are nece
9. passive bus monitor which does not assert any signals on the PCI bus The PCI bus signals are terminated with 10pf terminators at the maximum allowed stub length so that they provide the worst case PCI load Since the PCI Scope Preprocessor does not actively buffer the PCI bus signals no skew is introduced The MultiProbe configuration software on the diskette sets up the MultiProbe control module for analog analysis of the PCI Local Bus This manual is organized to help you quickly find the information you need e The Analyzing the PCI Local Bus chapter introduces you to the PCI Scope Preprocessor and lists the minimum equipment required and accessories supplied for PCI bus analysis e The Analog Analysis chapter explains how to configure the PCI Scope Preprocessor to perform analog analysis on your PCI bus e The General Information chapter provides some general information including the operating characteristics for the PCI Scope Preprocessor module and the pinout Analyzing the PCI Local Bus Duplicating the Master Diskette Accessories Supplied Minimum Equipment Required This chapter introduces you to the PCI Scope Preprocessor and lists the minimum equipment required and accessories supplied for PCI Local Bus analysis Before you use the PCI Preprocessor software make a duplicate copy of the master diskette Then store the master diskette and use the back up copy to configure your logic analysis system This will hel
10. rectory MULTIPRB on your hard disk and copy the files Connecting the MultiProbe Control Card to an Oscilloscope PCI_MUL DUT and PCI ADP from your PCI Scope Preprocessor diskette to that directory 3 Access the configuration menu of the MultiProbe Control card 4 Select POD setup for the POD that will be connected to the Scope Preprocessor 5 On the next menu select 2 Specify POD adapter and then select the file PCI ADP and select proceed 6 Return to the MultiProbe Configuration menu and Select Assign Signal Names 7 From the File selection menu select the MULTIPRB directory on the hard disk 6 Select the field next to File Select the file PCI MUL DUT 7 Load the file With PCI_MUL displayed in the File field select Load File Once you have completed loading these two files the PCI Scope Preprocessor is ready for PCI analog analysis and the configured POD in the MultiProbe configuration menu will appear as below MultiProbe E Configuration Pod EN PCI LogicScope Pod Assign Setup Signal Names mm C coco Rear View For further information on the operation of the MultiProbe Control Card refer to the HP 16535A MultiProbe Users Guide The operation of the PCI Scope Preprocessor is independent of the Oscilloscope that is attached to the MultiProbe Control Card Refer to the HP 16535A MultiProbe Control Users Guide for information on how to attach to the Oscilloscope 10 Analo
11. rsonality adapter follow the instructions for Programming the ground connections in your 208 MultiProbe High Density Pod Installation guide and program all the even numbered connections to ground 14 General Information This chapter provides additional reference information including the characteristics and signal connections for the PCI Scope Preprocessor module Characteristics The following operating characteristics are not specifications but are typical operating characteristics for the PCI Scope Preprocessor module Preprocessor Interface 32 64 bit PCI Local bus accepting the short card length and Compatibility universal connector pinout All PCI local bus ground pins of the universal board pinout are connected to the ground plane of the PCI Scope Preprocessor module JTAG Boundary Scan The PCI Scope Preprocessor does not implement JTAG Boundary SCAN Pins TDI and TBO pins 4a and 4b are connected together so the scan chain is not broken The PCI Present Pins No connection is made to the PCI signals PRSNT1 and PRSNT2 Standards Supported The PCI Local Bus Specification Revision 2 1 Power Requirements The PCI Scope Preprocessor contains no active components and therefore requires no power MultiProbe Pods The PCI Scope Preprocessor requires one 208 pin MultiProbe required Pod with the option 101 personality adapter Signal loading Per the PCI Local Bus Specification the PCI Scope Preprocessor presents only one electric
12. ssary 1 Install the PCI Scope Personality adapter option 101 to the 208 pin MultiProbe pod For information on how to configure the personality adapter from a blank personality adapter using the calibration fixture refer to the chapter on Analog Analysis in this users manual Do not touch the contact are on the MultiProbe Pod conductive elastomer which is on the bottom of the probe adapter If foreign material sticks to the contact area remove it using adhesive tape 2 Align the 208 Pin MultiProbe Pod with the retainer that is mounted on the top of the 208 pin package that is on the PCI Scope Preprocessor Attach the pod tightly using the knurled nut The pod will not lie flat against the board The PCI Scope Preprocessor can be installed in any slot of the PCI Local bus 1 Install the MultiProbe pod as described in the previous section 2 Align the PCI module with the appropriate slot on the target system and plug the module into the PCI connector If your PCI Local bus is 32 bits the upper portion of the edge connector will not be inserted into any connector This will not affect the modules operation on a 32 bit PCI Local bus The PCI Scope Preprocessor comes with MultiProbe compatible configuration files that assigns all the PCI signals to their proper pins To load the files 1 Install the PCI Scope Preprocessor software diskette in the HP16500B mainframe floppy drive 2 If you have not already done so create the di
13. with an instrument will execute its programming instructions when properly installed on that instrument FuturePlus Systems does not warrant that the operation of the hardware or software will be uninterrupted or error free The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Buyer Buyer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance NO OTHER WARRANTY IS EXPRESSED OR IMPLIED FUTUREPLUS SYSTEMS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE REMEDIES PROVIDED HEREIN ARE BUYER S SOLE AND EXCLUSIVE REMEDIES FUTUREPLUS SYSTEMS 5 Assistance SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER BASED ON CONTRACT TORT OR ANY OTHER LEGAL THEORY Product maintenance agreements and other customer assistance agreements are available for FuturePlus Systems products For assistance contact the factory Introduction How to Use This Manual The PCI Scope Preprocessor module provides a complete interface between any PCI add in slot and the HP MultiProbe system The Preprocessor interface connects the signals from the PCI Local bus to the inputs of a 208 PQFP package used as the MultiProbe connection point The PCI Scope Preprocessor is a

Download Pdf Manuals

image

Related Search

Related Contents

Mise en page 1  AL20081124  VirtualDJ 6 LE TC  Mode d`emploi vidéo 56,71 kB  Philips HQ4 microgroove 3 shaving heads Shaving heads  Panasonic SC-AK520 Stereo System User Manual  Philips widescreen flat TV 26PFL5522D  4″ Badger Tool Manual  Nous recherchons pour notre Département Scientifique  rimetal - Trimetal Máquinas para Baterias  