Home

HP c8000 Workstation Setup and Install

image

Contents

1. 5069 6357 p Optional hardware kit contents J 1539 63004 The optional hardware kit is required to install the mid weight slide kit into zi HP racks e ss Sem 0515 3019 M flathead screw 5185 6036 Front bracket 5184 2312 ZA Required tools The following tools are required for installation e T 25 Torx driver e Phillips screwdriver e Flathead screwdriver e M10 socket e Mid weight slide mounting alignment tool included with this kit Rack warning Z WARNING To reduce the risk of personal injury or damage to the equipment be sure that e The leveling feet are extended to the floor e The full weight of the rack rests on the leveling feet e The stabilizing feet are attached to the rack if it is a single rack installation e The racks are coupled together in multiple rack installations e Only one component is extended at a time A rack may become unstable if more than one component is extended for any reason Mid weight slides overview Perform one of the following e Install the mid weight slides in a rack Installing the mid weight slides in a rack on page 1 or e Ship a rack with an integrated server Shipping a rack with an integrated server on page 3 Installing the mid weight slides in a rack 1 Install the mid weight inner slides Installing the mid weight inner slides on page 1 2 Mark your rack columns using the mid weight slide mounting alignment
2. tool Marking your rack columns using the mid weight slide mounting alignment tool on page 1 3 Follow the appropriate installation procedure for your rack type o Installing the mid weight slides in round hole or square hole racks on page 2 o Installing the mid weight slides in threaded hole racks on page 2 o Installing the mid weight slides in early HP racks o on page 2 4 Optional Adjust the mid weight outer slide assemblies Optional Adjusting the mid weight outer slide assemblies on page 3 Installing the mid weight inner slides 1 Align the mid weight inner slide holes with the tabs on the server 2 Slide the mid weight inner slides toward the rear of the server until they lock into place Marking your rack columns using the mid weight slide mounting alignment tool 1 Using the height of the mid weight inner slides mark both sides of the mid weight slide mounting alignment tool 2 Using the marked mid weight slide mounting alignment tool mark the front and rear columns of the rack Item Description 1 Mark for HP 5U servers 2 Mark for HP 4U servers Mark for HP 2U and HP 3U servers Installing the mid weight slides in round hole or square hole racks NOTE If the rear slide brackets must adjust to shallower or deeper third party columns see Optional Adjusting the mid weight outer slide assemblie
3. HP Mid Weight Slide Kit 5069 6371 Installation Instructions OF Copyright 2006 2008 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Part Number 416755 003 March 2008 Third Edition About this device The HP Mid Weight Slide Kit 5069 6371 enables you to install HP 2U 3U 4U and 5U servers into HP round hole square hole threaded hole and early HP racks Kit contents If any of the following items are missing or damaged contact your HP authorized reseller The following hardware pieces are included in this kit a E 1 Cable Cable management arm 11539 63003 arm J1539 63003 _ Mid weight inner slides J1539 63001 A Mid weight outer slide assemblies J1539 63002 12 Hookand Hookandloop straps 1400 2030 Hookandloop straps 1400 2030 1400 2030 weight slide mounting alignment tool 5185 6098 Hardware kit contents nity pesoi i M5 x 30 mm screw 0515 2992 M5 x 10 mm screw 5021 2991 far 2 M5 x 16 mm screw 0515 3019 M4 x 8 mm screw 0515 2478 Crs M5 barrel nut 5065 7210 Tie down bracket
4. h the mid weight inner slides extended 1 Slide the server into the mid weight outer slide assemblies 2 Connect the cables to the server 3 Install and secure the cable management arm to the mid weight outer slide assemblies 4 T the cable management arm slide the server Optional Adjusting the mid weight outer slide nara assemblies NOTE These steps apply only if the adjustment of the outer slide assemblies are necessary to fit shallower or deeper third party racks 1 Remove the slide locking clips from the outer slide assemblies 5 Route the cables through the cable management arm N Adjust the slide assemblies for your rack and then install the slide locking clips 6 Shipping a rack with an integrated server c Using two M4 x 8 mm screws secure the mid weight inner slides to an HP 4U server NOTE If the rear slide brackets must adjust to shallower or deeper third party columns see Optional Adjusting the mid weight outer slide assemblies on page 3 NOTE All M4 screws must be torqued to 2 4 Nm 22 lb 1 Install the mid weight inner slides and secure them to the server using the required number of M4 x 8 mm screws a Using two M4 x 8 mm screws secure the mid weight inner slides to an HP 2U server d Using four M4 x 8 mm screws secure the mid weight inner slides to an HP 5U server b Using two M4 x 8 mm screws secure t
5. he mid weight inner slides to an HP 3U server 2 Using the height of the mid weight inner slides mark both sides of the mid weight slide mounting alignment tool eee eal OoD cod Ho 3 Using the marked mid weight slide mounting alignment tool 6 Install the mid weight outer slide assemblies by aligning the mark the front and rear columns of the rack center pin of the mid weight outer slide assemblies with the markings on the front and rear of the rack columns 7 Screw the M5 x 30 mm screws to the mid weight outer slide assemblies to secure it to the rack So e 60 6c ae z I fo Dewi oO O 3 Mark for HP 5U servers 9 a Mare Ia a Usenet Z WARNING Two people are needed to align and install Mark for HP 2U and HP 3U servers 4 Remove the top pin from the mid weight outer slide assemblies the server properly Do not install the server with the mid weight inner slides extended 8 Slide the server into the mid weight outer slide assemblies NOTE All M5 screws must be torqued to 6 2 Nm 55 lb 9 Connect the cables to the server 5 Install the M5 barrel nuts on the rack columns 20 0 00 o 9 9 9 Q Ce EC HEI BP y 2 E S CY CE o o oo e 10 Install and secure the cable management arm to the mid weight 13 outer slide assemblies N JEEE 11 Extending the cable management arm sl
6. ide the server forward 12 Route the cables through the cable management arm 14 15 Install hook and loop straps as needed to secure the cables NOTE The yellow plastic shipping tie is not included in the kit 0684 0860 or equivalent Install a yellow plastic shipping tie NOTE All M5 screws must be torqued to 6 2 Nm 55 lb Use the M5 x 16 mm screws to install and secure the tie down bracket to the mid weight right outer slide assembly If you have a square hole rack insert the M5 x 10 mm screw in hole 1 If you have a round hole rack insert the M5 x 10 mm screw in hole 2
7. king on the front and rear of the rack columns 5 Proceed to Sliding the server into the mid weight outer slide assemblies on page 2 Installing the mid weight slides in early HP racks 1 Install the mid weight inner slides Installing the mid weight inner slides on page 1 2 Mark your rack columns using the mid weight slide mounting alignment tool Marking your rack columns using the mid weight slide mounting alignment tool on page 1 3 Remove the front and rear brackets from the mid weight outer slide assemblies and save the four nuts 4 Align 1 the top hole of the front brackets with the markings on the front of the rack columns Secure the front brackets to the rack using M5 x 16 mm screws 2 5 Transfer the markings from the front of the rack columns to the sides of the rack columns and install the mid weight outer slide assemblies by aligning the threaded side studs with the markings on the rack columns 6 Secure the front of the outer slide assemblies to the rack columns using the nuts from step 3 Secure the rear of the mid weight outer slide assemblies to the rack columns using M6 flathead screws and the nuts from step 3 7 Proceed to Sliding the server into the mid weight outer slide assemblies on page 2 Sliding the server into the mid weight outer slide assemblies AN WARNING Two people are needed to align and install the server properly Do not install the server wit
8. s on page 3 1 Install the mid weight inner slides Installing the mid weight inner slides on page 1 2 Mark your rack columns using the mid weight slide mounting alignment tool Marking your rack columns using the mid weight slide mounting alignment tool on page 1 3 Install the mid weight outer slide assemblies by aligning the center pin of the mid weight outer slide assemblies with the markings on front and rear of the rack columns 4 Proceed to Sliding the server into the mid weight outer slide assemblies on page 2 Installing the mid weight slides in threaded hole racks NOTE If the rear slide brackets must adjust to shallower or deeper third party columns see Optional Adjusting the mid weight outer slide assemblies on page 3 1 Install the mid weight inner slides Installing the mid weight inner slides on page 1 2 Mark your rack columns using the mid weight side mounting alignment tool Marking your rack columns using the mid weight slide mounting alignment tool on page 1 3 Remove the three pins from the front and rear of the mid weight outer slide assemblies NOTE Screws for threaded hole racks are not supplied in the kit These screws are supplied by your rack manufacturer 4 Using the screws supplied by your rack manufacturer install the mid weight outer slide assemblies by aligning the center hole of the mid weight outer slide assemblies with the mar

Download Pdf Manuals

image

Related Search

Related Contents

Samsung HT-TWP32 User Manual  Samsung PL170 Керівництво користувача    User`s Manual  Hand made, 30 watts, Tube Guitar Amplifier    506713 – LogiLink WC0042 Mode d`emploi en Français  

Copyright © All rights reserved.
Failed to retrieve file