Honeywell Thermostat TH8000 User's Manual
Contents
1. 0690 0700 0710 Furnace filter change reminder Humidifier pad change reminder UV lamp change reminder Adaptive Intelligent Recovery Program periods Compressor protection Heat temperature range stop Cool temperature range stop Clock format Extended fan timer heat Extended fan timer cool Keypad lock Heat temperature control Cool temperature control Temperature display offset RESET a NA Ox O WHO OIRAO0ODN 0 O WAN OAN N 0 0 off 10 day run time about 1 month 30 day run time about 3 months 60 day run time about 6 months 90 day run time about 9 months 120 day run time about 1 year 365 day run time about 3 years off 90 calendar days 180 calendar days 365 calendar days off 365 calendar days On See page 11 Off 4 program periods Wake Leave Return Sleep 2 program periods Wake Sleep 5 minute compressor off time See page 11 Other options 0 1 2 3 or 4 minute off time Max heat temperature setting is 90 F 32 C Other options 40 89 F 4 C to 32 C Min cool temperature setting is 50 F 10 C Other options 51 99 F 11 C to 37 C 12 hour time i e 3 30 pm 24 hour time i e 15 30 Off Fan runs for 90 seconds after call for heat ends Off Fan runs for 90 seconds after call for cooling ends Keypad unlocked fully functional Partially locked access to temperature settings only Fully locke
2. Cableado S lo retire el empalme de f brica para Empuje el exceso de cable de vuelta en la abertura los sistemas de dos transformadores de la pared Tapone la abertura de la pared con aislamiento no inflamable HEAT PUMP Ny CONVENTIONAL Al a El Bl El 11 Designaciones de terminales Las reas sombreadas corresponden nicamente al modelo TH8320 TH8321 Letras convencionales Letras de la bomba de calefacci n R Alimentaci n de energ a de calefacci n R Alimentaci n de energ a de calefacci n Conecte al lado secundario del Conecte al lado secundario del transformador del sistema de calefacci n transformador del sistema de calefacci n Re Alimentaci n de energ a de refrigeraci n Re Alimentaci n de energ a de refrigeraci n Conecte al lado secundario del Conecte al lado secundario del transformador del sistema de refrigeraci n transformador del sistema de refrigeraci n C Cable com n del lado secundario del C Cable com n del lado secundario del transformador del sistema de refrigeraci n transformador del sistema de refrigeraci n si hay 2 transformadores Y Contactor del compresor de 1 etapa W Retransmisor de calefacci n de 1 etapa Y2 Contactor del compresor de 2 etapa W2 Retransmisor de calefacci n de 2 etapa Aux Retransmisor auxiliar de calefacci n Y Contactor del compresor de 1 etapa G Retransmisor del ventilador Y2 Contactor del compresor de 2 etapa E Retransmisor de calefacci n de emerg
3. el termostato se ajusta en Em Heat monitor del sistema cuando se ajusta en Heat Cool u Off 8 Instale el empalme de campo entre los terminales Aux y E si no hay un retransmisor de calefacci n de emergencia 2H 2C Bomba de calefacci n sin calefacci n auxiliar Y2 Retransmisor del compressor 2 Re Alimentaci n de energ a 1 R R Rc unidos por empalme O B_ V lvula de cambio 5 Y Retransmisor del compresor 1 G Retransmisor del ventilador Cc 24 VCA Com n 3 S1 Sensor opcional S2 Sensor opcional 3H 2C Bomba de calefacci n con calefacci n auxiliar Y2 Retransmisor del compressor 2 L Monitor del equipo 6 7 E Retransmisor de calefacci n de emergencia 8 Aux Retransmisor auxiliar de calefacci n 8 Re Alimentaci n de energ a 1 R R Rc unidos por empalme O B_ V lvula de cambio 5 Y Retransmisor del compresor 1 G Retransmisor del ventilador Cc 24 VCA Com n 3 S1 Sensor opcional S2 Sensor opcional Gu a de instalaci n Retire la leng eta y arme el termostato Retire la leng eta Alinee las espigas de la parte de atr s del termostato con las ranuras de la placa de montaje luego presione suavemente hasta que el termostato calce en su lugar Ajuste de fecha y hora Oprima Aw f ae Y Oprima AW para ajustar para ajustar la fecha ME A la hora Oprima AY para ajustar el mes Ly ri
4. modelos e TH8110U Para sistemas 1 de calefacci n 1 de refrigeraci n e TH8320U Para hasta 3 sistemas de calefacci n 2 de refrigeraci n e TH8321U Para hasta 3 sistemas de calefacci n 2 de refrigeraci n con deshumidificaci n Retire el termostato de la placa de montaje y g relo para ver el n mero de modelo Tipos de sistemas e S lo calefacci n sistemas de doble cableado alimentaci n de energ a para abrir y cerrar v lvulas de zona serie 20 y abrir e Aire caliente agua caliente estufas normalmente v lvulas de zona de alta eficiencia bombas de calefacci n vapor gravedad e Calefacci n a gas petr leo o el ctrica con aire acondicionado e S lo calefacci n con ventilador e S lo refrigeraci n e Sistemas de calefacci n de 750 mV Este termostato tiene una bater a de litio que puede contener perclorato Perclorato puede ser necesario manipularlo con m todos especiales Visite www dtsc ca gov hazardouswaste perchlorate Necesita ayuda Para recibir asistencia con este producto visite http yourhome honeywell com o llame gratis al Servicio de Atenci n al Cliente Honeywell al 1 800 468 1502 Marca registrada en EE UU Patente en EE UU N 6595430 D509151 y otras patentes pendientes Copyright O 2007 Honeywell International Inc Todos los derechos reservados 69 1896ES 1 Gu a de instalaci n Instalaci n de la placa de montaje 1 Separe la placa de montaje del Sujete la parte superi
5. setting Press DONE to exit 8 save settings Shaded areas below apply only to TH8320 TH8321 0120 0130 0140 0150 0160 0170 0180 0190 0200 0210 0220 0230 Year first two digits Year second two digits Month Date Schedule format System type Fan control heating Changeover valve O B terminal Auxiliary heat External fossil fuel kit 1st stage com pressor cycle rate 2nd stage com pressor cycle rate 20 21 06 6 a ahon s Of U om 20O O 0 a 2000 2078 2101 2178 2006 Other options 00 99 Other options 1 12 Other options 1 31 7 day programming Non programmable 1 heat 1 cool conventional 1 heat 1 cool heat pump no aux heat Heat only 2 wire systems Heat only with fan Hot water Series 20 system power to open amp close zone valves normally open zone valves Cool only 2 heat 1 cool heat pump with aux heat 2 heat 2 cool multistage conventional 2 heat 1 cool multistage conventional 1 heat 2 cool multistage conventional 2 heat 2 cool heat pump no aux heat 3 heat 2 cool heat pump with aux heat Gas Oil heat equipment controls heating fan Electric furnace thermostat controls heating fan O B terminal controls valve in cooling O B terminal controls valve in heating Electric backup heat Fossil fuel backup heat External fossil fuel kit controls backup heat Thermostat controls backup heat outd
6. temperatura exterior cceeeeeeeeee N mero de pieza C7089U1006 Sensor remoto de temperatura interior N mero de pieza C7189U1005 Cubierta N mero de pieza 32003796 001 Para cubrir marcas dejadas por otros termostatos 11 Gu a de instalaci n Especificaciones Rangos de temperatura Reg menes el ctricos e Calefacci n 40 a 90 F 4 5 a 32 C e Refrigeraci n 50 a 99 F 10 a 37 C Terminal Tension 50 60Hz Corriente W Calefacci n 20 30 VCA 0 02 1 0 A Temperatura ambiental de Pila 750 mV DC 100 mA DC funcionamiento e 0 a120 F 18 a 49 C W2 Calefacci n 20 30 VCA 0 02 0 6 A n Y Refrigeraci n 20 30 VCA 0 02 1 0 A Temperatura de env o D e 30 a 150 F 34 a 66 C Y2 Refrigeraci n 20 30 VCA 0 02 1 0 A Humedad relativa de funcionamiento Aux Calefacci n ee auxiliar 20 30 VCA 0 02 0 6 A e 5 a 90 sin condensaci n O B Cambio 20 30 VCA 0 02 0 6 A Dimensiones fisicas E Calefacci n 4 9 16 H x 6 A x 1 3 8 P de emergencia 20 30 VCA 0 02 1 0 A 116 mm H x 152 mm A x 35 mm P L Reconfiguraci n de bomba de calefacci n 20 30 VCA 0 02 0 6 A Necesita ayuda Para recibir asistencia con este producto visite http yourhome honeywell com o llame gratis al Servicio de Atenci n al Cliente Honeywell al 1 800 468 1502 Soluciones para automatizaci n y control Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive
7. 12 CPH Electric emergency heat Steam or gravity systems Hot water systems amp furnaces of 90 efficiency Gas or oil furnaces of less than 90 efficiency Other options 2 4 6 7 8 10 11 12 CPH Backlight on for approx 8 seconds after keypress Backlight always on low intensity full bright after key press requires 24VAC connection Manual changeover Heat Cool Off Automatic changeover Heat Cool Auto Off Heat cool temperature 3 F apart 1 5 C See page 11 Other options 2 9 2 F to 9 F 1 C to 5 C Fahrenheit Celsius Auto change to daylight savings time 2007 and be yond for areas that use the new 2007 DST calendar Auto change to daylight savings time through 2006 and for areas that do not use the new 2007 DST calendar Daylight savings time is turned off No remote sensor Outdoor sensor display only Outdoor control sensor select heat pumps See page 11 Indoor sensor No heat pump compressor lockout Other options 15 20 25 30 35 40 F 9 5 C to 7 C No heat pump auxiliary lockout Other options 40 45 50 55 60 F 4 5 C to 15 5 C No dehumidification control Thermostat controls dehumidification with air conditioner See page 11 Continued on next page VisionPRO TH8000 Series Installer setup Setup functions Settings amp Options factory default in bold 0500 0510 0520 0530 0540 0580 0600 0610 0640 0650 0660 0670 0680
8. Honeywell Installation Guide TAR VisionPRO TH8000 Series AS Touch screen Programmable Thermostat This manual covers the following models e TH8110U For 1 Heat 1 Cool systems e TH8320U For up to 3 Heat 2 Cool systems e TH8321U For up to 3 Heat 2 Cool systems with dehumidification Pull thermostat from wallplate and turn over to find model number System Types e Heat only two wire systems power to open and close zone valves Series 20 and normallyopen zone valves e Gas oil or electric heat with air conditioning e Warm air hot water highefficiency furnaces heat pumps steam gravity e Cool only e 750 mV heating systems e Heat only with fan This thermostat contains a Lithium battery which may contain Perchlorate material Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate Need Help For assistance with this product please visit http yourhome honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 U S Registered Trademark US Patent No 6595430 D509151 and other patents pending Copyright 2007 Honeywell International Inc 69 1896ES 1 All rights reserved Installation Guide Waliplate installation 1 Separate wallplate from thermostat Grasp top and bottom of wallplate and pull to remove from thermostat 2 Mount wallplate as shown below Drill 3 16 holes for drywall Drill 7 32 holes for pl
9. North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V4Z9 http yourhome honeywell com Impreso en los EE UU en papel H li amp reciclado que contiene por lo menos oneywe un 10 de fibras de papel reciclable Marca registrada de los EE UU Patente en EE UU N 6595430 D509151 y otras patentes pendientes 2007 Honeywell Internacional Inc 69 1896ES 1 M S Rev 02 07
10. Power supply Provide disconnect means and overload protection as required 2 Remove jumper for 2 transformer systems 8 Optional 24VAC common connection 4 Common connection must come from cooling transformer VisionPRO TH8000 Series Wiring guide heat pump systems Shaded areas below apply only to TH8320 TH8321 1H 1C Heat Pump no auxiliary heat 2H 2C Heat Pump no auxiliary heat Re Power 1 Y2 Compressor 2 relay R R Rc joined by jumper Re Power 1 O B Changeover valve 5 R R Rc joined by jumper Y Compressor relay O B Changeover valve 5 G Fan relay Y Compressor 1 relay Cc 24VAC common 3 G Fan relay 1 Optional outdoor remote sensor Cc 24VAC common 3 s2 Optional outdoor remote sensor S1 Optional outdoor remote sensor S2 Optional outdoor remote sensor 2H 1C Heat Pump with auxiliary heat L Equipment monitor 6 7 3H 2C Heat Pump with auxiliary heat E Emergency heat relay 8 Y2 Compressor 2 relay Aux Auxiliary heat relay Heat 2 8 L Equipment monitor 6 7 Re Power 1 E Emergency heat relay 8 R R Rc joined by jumper Aux Auxiliary heat relay Heat 2 8 O B Changeover valve 5 Re Power 1 Y Compressor relay R R Rc joined by jumper G Fan relay O B _ Changeover valve 5 Cc 24VAC common 3 Y Compressor 1 relay S1 Optional outdoor remote sensor G Fan rel
11. ador S1 Sensor opcional Cc 24 VCA Com n 3 s2 Sensor opcional S1 Sensor opcional S2 Sensor opcional Sistema s lo de calefacci n Serie 20 Re R Rc unidos por empalme Sistema de s lo refrigeraci n R V lvula terminal R Serie 20 1 Re Alimentaci n de energ a 1 w V lvula terminal B Serie 20 R R Rc unidos por empalme Y V lvula terminal W Serie 20 Y Contactor del compresor Cc 24 VCA Com n 3 G Retransmisor del ventilador S1 Sensor opcional c 24 VCA Com n 3 s2 Sensor opcional S1 Sensor opcional S2 Sensor opcional Sistema 2H 2C 1 transformador Y2 Retransmisor de refrigeraci n Sistema 2H 2C 2 transformadores w2 Retransmisor de calefacci n 2 Y2 Retransmisor de refrigeraci n 2 Reg Alimentaci n de energ a 1 W2 Retransmisor de calefacci n 2 R R Rc unidos por empalme Re Energ a de refrigeraci n 1 2 w Retransmisor de calefacci n R Energ a de calefacci n 1 2 Y Retransmisor de refrigeraci n 1 wW Retransmisor de calefacci n 1 G Retransmisor del ventilador Y Retransmisor de refrigeraci n 1 c 24 VCA Com n 3 G Retransmisor del ventilador S1 Sensor opcional c 24 VCA Com n 3 4 S2 Sensor opcional S1 Sensor opcional S2 Sensor opcional Ver notas a continuaci n 1 Alimentaci n de energ a Provee medios de desconexi n y protecci n contra sobrecarga seg n se requiera 2 Retirar el empalme en sistemas de 2 transform
12. adores 8 Conexi n com n de 24 VCA opcional 4 Conexi n com n debe provenir del transformador de refrigeraci n VisionPRO TH8000 Serie Cableado Gu a para el cableado sistemas de bombeo de calefacci n Las reas sombreadas corresponden nicamente al modelo TH8320 TH8321 1H 1C Bomba de calefacci n sin calefacci n auxiliar Re Alimentaci n de energ a 1 R R Rc unidos por empalme O B V lvula de cambio 5 Y Retransmisor del compresor G Retransmisor del ventilador Cc 24 VCA Com n 3 S1 Sensor opcional s2 Sensor opcional 2H 1C Bomba de calefacci n con calefacci n auxiliar L Monitor del equipo 6 7 E Retransmisor de calefacci n de emergencia 8 Aux Retransmisor auxiliar de calefacci n 8 Re Alimentaci n de energ a 1 R R Re unidos por empalme O B_ V lvula de cambio 5 Y Retransmisor del compresor G Retransmisor del ventilador Cc 24 VCA Com n 3 S1 Sensor opcional s2 Sensor opcional Ver notas a continuaci n 1 Alimentaci n de energ a Provee medios de desconexi n y protecci n contra sobrecarga seg n se requiera 8 Conexi n com n de 24 VCA opcional 5 O B ajustado para controlar ya sea O o B en configuraci n del instalador 6 Si se usa el terminal L se debe conectar el com n de 24 VCA terminal C 7 Reajuste de la bomba de calefacci n recibe alimentaci n de energ a cuando
13. ama del instalador al original de f brica s lo se conservan los ajustes de fecha y hora 9 Gu a de instalaci n Prueba del sistema del instalador Durante la configuraci n del instalador oprima y N mero Estado del repetidamente hasta que aparezca Test en pantalla de prueba sistema DONE Oprima AW Oprima AY para seleccionar para cambiar la prueba el estado Oprima DONE para terminar la prueba Las reas sombreadas corresponden nicamente al modelo TH8320 TH8321 Prueba del sistema Estado del sistema 1 Sistema de 0 Compresor y ventilador apagados refrigeraci n 1 Compresor y ventilador encendidos 2 Compresor de segunda etapa encendido 2 Sistema de O Ventilador apagado ventilador 1 Ventilador encendido 3 Sistema de O Calefacci n y ventilador apagados calefacci n 1 Calefacci n encendida ventilador encendido si la funci n 0170 se fija en bomba de calefacci n o si la funci n 0180 se fija en 1 Ver pagina 6 2 Compresor de segunda etapa encendido 3 Compresor de tercera etapa encendido 4 Sistema de 0 Calefacci n y ventilador apagados calefacci n de 1 Calefacci n y ventilador encendidos emergencia 2 Calefacci n de segunda etapa encendido Calefacci n auxiliar la protecci n del compresor Para evitar da os al equipo evite ciclar el compresor 1 PRECAUCI N RIESGO DE DA OS AL EQUIPO Durante las pruebas se suspende demasiado r pido 10 VisionPRO TH8000 Se
14. an autom ticamente el sistema de refrigeraci n para reducir la humedad al bajar la temperatura hasta 3 grados por debajo del ajuste actual de refrigeraci n Cierre de temperatura de la bomba de calefacci n con combustible f sil de respaldo Si el termostato est instalado con un sensor exterior opcional usted puede seleccionar una temperatura de cierre del compresor Funci n 0350 Cuando la temperatura del exterior es inferior a la temperatura de corte s lo funciona la calefacci n auxiliar Cuando la temperatura del exterior es superior a la temperatura de corte s lo funciona el compresor Cierres de temperatura de la bomba de calefacci n con calefacci n el ctrica de respaldo Si el termostato est instalado con un sensor exterior opcional usted puede seleccionar una temperatura de cierre del compresor Funci n 0350 y o una temperatura de corte de la calefacci n auxiliar Funci n 0360 Cuando la temperatura del exterior es inferior a la temperatura de corte del compresor s lo funciona la calefacci n auxiliar Cuando la temperatura del exterior es superior a la temperatura de corte de la calefacci n auxiliar s lo funciona el compresor Si la temperatura exterior se encuentra entre las temperaturas de corte del compresor y la calefacci n auxiliar pueden funcionar tanto el compresor como la calefacci n auxiliar Accesorios y piezas de recambio Comun quese con su distribuidor para encargar piezas de repuesto Sensor de
15. aster Wire hole Mounting screws Wall anchors Must be installed by a trained experienced technician e Read these instructions carefully Failure to follow these instructions can damage the product or cause a hazardous condition f CAUTION ELECTRICAL HAZARD Can cause electrical shock or equipment damage Disconnect power before beginning installation MERCURY NOTICE A If this product is replacing a control that contains mercury in a sealed tube do not place the old control in the trash Contact your local waste management authority for instructions regarding recycling and proper disposal 2 VisionPRO TH8000 Series Power options HEAT PUMP CONVENTIONA For 24VAC primary power connect common Insert supplied batteries for side of transformer to C terminal primary or backup power Remove factory installed jumper Push excess wire back into the wall opening Plug only for two transformer systems wall opening with non flammable insulation HEAT PUMP gt CONVENTIONA ai A El El E Terminal Designations shaded areas below apply only to TH8320 TH8321 Conventional Terminal Letters Heat Pump Terminal Letters R Heating power Connect to secondary R Heating power Connect to secondary side of heating syste
16. ay S2 Optional outdoor remote sensor Cc 24VAC common 3 S1 Optional outdoor remote sensor S2 Optional outdoor remote sensor See notes below 1 Power supply Provide disconnect means and overload protection as required 3 Optional 24VAC common connection 5 O B set to control as either O or B in installer setup 6 If L terminal is used 24VAC common terminal C must be connected 7 Heat pump reset powered continuously when thermostat is set to Em Heat system monitor when set to Heat Cool or Off 8 Install field jumper between Aux and E terminals if there is no emergency heat relay Installation Guide Remove tab and mount thermostat Remove tab Align pins on back of thermostat with slots in wallplate then push gently until thermostat snaps into place Set date and time Press AW Press AW to set date to set time TUE Press AW 15 a to set month Press AW Ea Ly to set year A a A Press DONE to save changes Press DONE to save and exit Installer setup 1 Press SYSTEM 2 Press and hold these two buttons until the display changes TUE ersen E 3 Change settings E oer OleO Ea SCHED HOLD VisionPRO TH8000 Series Installer setup Function Setting Press AV to select function Setup functions Settings Options factory default in bold Press AW to change
17. d Standard temperature control recommended Choose if room is warmer than set temperature Choose if room does not reach set temperature Standard temperature control recommended Choose if room is cooler than set temperature Choose if room does not reach set temperature Thermostat displays actual room temperature Other options 3 2 1 1 2 3 F offset 1 5 C to 1 5 C No reset Reset installer options amp program schedule to factory default only date and time settings are retained Installation Guide Installer system test During installer setup press Y Test System repeatedly until Test appears number e status a a DICO cu Lv P resp G fel ail 74 05 Press AW to Press AW to select test change status Press DONE to terminate testing Shaded areas below apply only to TH8320 TH8321 System test System status 1 Cooling system Compressor and fan turn off Compressor and fan turn on Second stage compressor turns on Fan turns off Fan turns on 2 Fan system Heat and fan turn off Heat turns on fan on if Function 0170 is set for heat pump or if Function 0180 is set to 1 See page 6 Second stage heat turns on Third stage heat turns on 3 Heating system O 0 NaO Heat and fan turn off Heat and fan turn on Second stage heat turns on Auxiliary heat 4 Emergency heating system N0 WN CAUTION EQUIPMENT DAMAGE HAZARD Compressor pro
18. d as calendarios 365 d as calendarios off 365 d as calendarios On Ver pagina 11 Off 4 periodos del programa Wake Leave Return Sleep 2 periodos del programa Wake Sleep Cinco minutos de compresor apagado Ver p gina 11 Otras opciones 0 1 2 3 o 4 minutos apagado Temperatura de calefacci n m xima es 90 F 32 C Otras opciones 40 89 F 4 C a 32 C Temperatura de refrigeraci n m nima es 50 F 10 C Otras opciones 51 99 F 11 C a 37 C Horario de 12 horas ej 3 30 pm Horario de 24 horas ej 15 30 pm off El ventilador funciona durante 90 segundos despu s de terminada la demanda de calor off El ventilador funciona durante 90 segundos despu s de terminada la demanda de fr o Teclado desbloqueado totalmente funcional Parcialmente bloqueado s lo acceso a ajustes de temperatura Completamente bloqueado Control est ndar de la temperatura recomendado Elija si la temperatura ambiente es m s c lida que la establecida Elija si la temperatura ambiente no alcanza la temperatura establecida Control est ndar de la temperatura recomendado Elija si la temperatura ambiente es m s fr a que la establecida Elija si la temperatura ambiente no alcanza la temperatura establecida El termostato muestra la temperatura real de la habitaci n Otras opciones 3 2 1 1 2 3 F 1 5 C to 1 5 C Sin reconfiguraci n Reconfigure las opciones y el horario de progr
19. de eficiencia Para estufas de gas o petr leo con menos de 90 de eficiencia Otras opciones 2 4 6 7 8 10 11 12 CPH Calefacci n el ctrica de emergencia Sistemas de vapor o gravedad Sistemas de agua caliente y estufas de 90 de eficiencia Para estufas de gas o petr leo con menos de 90 de eficiencia Otras opciones 2 4 6 7 8 10 11 12 CPH Iluminaci n encendida por aprox 8 seg despu s de oprimir tecla Iluminaci n siempre encendida en baja intensidad brillo total despu s de oprimir tecla requiere conexi n de 24 VCA Cambio manual Heat Cool Off Cambio autom tico Heat Cool Auto Off Temp Cal Ref con 3 F de diferencia 1 5 C Ver p 11 Otras opciones 2 9 2 F a 9 F 1 C a 5 C Fahrenheit Celsius Cambio autom tico a horario de ahorro de energ a diurno 2007 y posterior para reas que usan el nuevo calendario 2007 DST Cambio autom tico a horario de ahorro de energ a diurno 2006 y para reas que no usan el nuevo calendario 2007 DST El horario de ahorro de energ a diurno est desactivado No hay sensor remoto Sensor exterior s lo pantalla Sensor de control exterior bombas de calefacci n Ver p 11 Sensor de interior Sin cierre de compresor de bomba de calefacci n Otras opciones 15 20 25 30 35 40 F 9 5 C a 7 C Sin cierre de auxiliar de bomba de calefacci n Otras opciones 40 45 50 55 60 F 4 5 C a 15 5 C Sin control de deshumidificaci n E
20. encia G Retransmisor del ventilador L Reajuste de la bomba de calefacci n recibe S1 Sensor opcional para exteriores o remoto alimentaci n de energ a cuando el sistema S2 Sensor opcional para exteriores o remoto se ajusta en Em Heat monitor del sistema cuando se ajusta en Heat Cool u Off O B V lvula de cambio para bombas de calefacci n S1 Sensor opcional para exteriores o remoto S2 Sensor opcional para exteriores o remoto Gu a de instalaci n Cableado Gu a para el cableado sistemas convencionales Las reas sombreadas corresponden nicamente al modelo TH8320 TH8321 Sistema 1H 1C 1 transformador Sistema 1H 1C 2 transformadores Re Alimentaci n de energ a 1 Re Energ a de refrigeraci n 1 2 R R Rc unidos por empalme R Energ a de calefacci n 1 2 w Retransmisor de calefacci n Ww Retransmisor de calefacci n Y Contactor del compresor Y Contactor del compresor G Retransmisor del ventilador G Retransmisor del ventilador Cc 24 VCA Com n 3 Cc 24 VCA Com n 3 4 S1 Sensor opcional S1 Sensor opcional s2 Sensor opcional s2 Sensor opcional Sistema s lo calefacci n Sistema de s lo calefacci n con ventilador Re Alimentaci n de energ a 1 Re Alimentaci n de energ a 1 R R Rc unidos por empalme R R Rc unidos por empalme w Retransmisor de calefacci n Ww Retransmisor de calefacci n Cc 24 VCA Com n 3 G Retransmisor del ventil
21. ente abiertas 6 S lo refrigeraci n 7 Bomba de calefacci n 2 calefacci n 1 refrigeraci n sin calefacci n aux 8 2calefacci n 2 refrigeraci n de etapas m ltiples convencional 9 2calefacci n 1 refrigeraci n de etapas m ltiples convencional 10 1 calefacci n 2 refrigeraci n de etapas m ltiples convencional 11 2calefacci n 2 bomba de refrigeraci n sin calefacci n aux 12 3 calefacci n 2 bomba de refrigeraci n sin calefacci n aux 0180 Ventilador O Calefacci n a gas petr leo el equipo controla el calefacci n ventilador de calefacci n 1 Estufa el ctrica el termostato controla el ventilador de la calefacci n Terminal O B controla la v lvula en refrigeraci n Terminal O B controla la v lvula en calefacci n 0190 V lvula de cambio terminal O B 0200 Calefacci n auxiliar Calefacci n el ctrica de respaldo Calefacci n de combustible f sil de respaldo 0210 Juego para Juego de combustible f sil externo controla la combustible f sil calefacci n de respaldo 0 0 externo 0 Termostato controla la calefacci n de respaldo necesita sensor exterior 0220 Frecuencia del ciclo 3 Recomendada para la mayor a de los compresores del compresor de 1 Otras opciones 1 2 4 5 o 6 CPH etapa 0230 Frecuencia del ciclo 3 Recomendada para la mayor a de los compresores del compresor de 2 Otras opciones 1 2 4 5 o 6 CPH etapa Contin a en la p gina siguiente Gu a de instalaci n Configu
22. l setting Heat Pump Temperature Lockout with fossil fuel backup If the thermostat is installed with an optional outdoor sensor you can select a compressor lockout temperature Function 0350 When the outdoor temperature is below the lockout temperature only the auxiliary heat operates When the outdoor temperature is above the lockout temperature only the compressor operates Heat Pump Temperature Lockouts with electric heat backup If the thermostat is installed with an optional outdoor sensor you can select a compressor lockout temperature Function 0350 and or an auxiliary heat lockout temperature Function 0360 When the outdoor temperature is below the compressor lockout temperature only the auxiliary heat operates When the outdoor temperature is above the auxiliary lockout temperature only the compressor operates If the outdoor temperature is between the compressor and auxiliary lockout temperatures both the compressor and auxiliary heat can operate Accessories amp replacement parts Please contact your distributor to order replacement parts Outdoor temperature sensor Part Number C7089U1006 Remote indoor temperature sensor Part Number C7189U1005 Cover plate A Part Number 32003796 001 Use to cover marks left by old thermostats 11 Installation Guide Specifications Temperature Ranges e Heat 40 to 90 F 4 5 to 32 C e Cool 50 to 99 F 10 to 37 C Operating Ambient Tem
23. l termostato controla la deshumidificaci n con el acondi cionador de aire Ver p 11 Suite la page suivante VisionPRO TH8000 Serie Configuraci n del instalador Funci n 0500 0510 0520 0530 0540 0580 0600 0610 0640 0650 0660 0670 0680 0690 0700 0710 Recordatorio de cambio del filtro de la estufa Recordatorio de cambio del pa o del humidificador Recordatorio de cambio de l mpara Uv Adaptive Intelligent Recovery Per odos del programa Protecci n del compresor Tope de rango de temp de calefacci n Tope de rango de temp de refrigeraci n Formato de reloj Temporizador de ventilador extendido calefacci n Temporizador de ventilador extendido refrigeraci n Bloqueo del teclado Control de temp de calefacci n Control de temp de refrigeraci n Compensaci n de la pantalla de temp RESET Ajustes y opciones configuraci n de f brica en negritas 0 1 2 3 4 5 6 0 1 2 3 0 1 anh Om 50 12 24 90 oo NN Nago _ Off Tiempo de funcionamiento de 10 dias alrededor de 1 mes Tiempo de funcionamiento de 30 dias alrededor de 3 meses Tiempo de funcionamiento de 60 dias alrededor de 6 meses Tiempo de funcionamiento de 90 dias alrededor de 9 meses Tiempo de funcionamiento de 120 dias alrededor de 1 a o Tiempo de funcionamiento de 365 d as alrededor de 3 a os off 90 d as calendarios 180
24. m transformer side of heating system transformer Re Cooling power Connect to secondary Rc Cooling power Connect to secondary side of cooling system transformer side of cooling system transformer C Common wire from secondary side of C Common wire from secondary side of cooling transformer if 2 transformers cooling system transformer W 1st stage heat relay Y 1st stage compressor contactor W2 2nd stage heat relay Y2 2nd stage compressor contactor Y 1st stage compressor contactor Aux Auxiliary heat relay Y2 2nd stage compressor contactor G Fan relay G Fan relay E Emergency heat relay S1 Optional outdoor or remote sensor L Heat pump reset powered continuously 2 Optional outdoor or remote sensor when System is set to Em Heat system monitor when set to Heat Cool or Off O B Changeover valve for heat pumps S1 Optional outdoor or remote sensor S2 Optional outdoor or remote sensor Installation Guide Wiring guide conventional systems Shaded areas below apply only to TH8320 TH8321 1H 1C System 1 transformer 1H 1C System 2 transformers Re Power 1 Re Power cooling transformer 1 2 R R Rc joined by jumper R Power heating transformer 1 2 WwW Heat relay Ww Heat relay Y Compressor contactor Y Compressor contactor G Fan relay G Fan relay Cc 24VAC common 3 Cc 24VAC common 3 4 S1 Optional outdoor remote sensor S1 Optional outdoor remote sensor s2 Optional outdoor remote se
25. ma w ES para saa m cundo y 5 v iii aaa a d Oprima DONE para guardar los cambios Oprima DONE para salir y guardar los ajustes Configuraci n del instalador 1 Oprima SYSTEM 2 Mantenga oprimi dos estos dos botones hasta que z cambie la pantalla Lal TJ Ipside AUTO cm 3 Cambie los PR a ajustes seg n sea 0 120 cu LILIAN necesario ver v v p ginas 7 9 E a J VisionPRO TH8000 Serie Configuraci n del instalador Funci n Ajuste DONE Oprima AW para Oprima AW para Oprima DONE para salir y guardar seleccionar la funci n cambiar los ajustes los ajustes Funci n Ajustes y opciones configuraci n de f brica en negritas Las reas sombreadas corresponden nicamente al modelo TH8320 TH8321 0120 A o 20 2000 2078 primeros 2 d gitos 21 2101 2178 0130 A o 06 2006 segundos 2 d gitos Otras opciones 00 99 0140 Mes 6 Otras opciones 1 12 0150 Fecha 15 Otras opciones 1 31 0160 Formato de horario programaci n de 7 d as No programable 4 0 0170 Tipos de sistemas 1 1calefacci n 1 refrigeraci n convencional 2 Bomba de calefacci n 1 calefacci n 1 refrigeraci n sin calefacci n aux 3 S lo calefacci n sistema de doble cableado 4 S lo calefacci n con ventilador 5 S lo calefacci n sistema Serie 20 alimentaci n de v lvulas de zona para abrir y cerrar v lvulas de zona normalm
26. nsor s2 Optional outdoor remote sensor Heat Only System Re Power 1 Heat Only System With Fan Re Power 1 R R Rc joined by jumper R R Rc joined by jumper WwW Heat relay Ww Heat relay Cc 24VAC common 3 G Fan relay S1 Optional outdoor remote sensor c 24VAC common 3 s2 Optional outdoor remote sensor S1 Optional outdoor remote sensor Heat Only System Series 20 Re R Rc joined by jumper s2 Optional outdoor remote sensor Cool Only System R Series 20 valve terminal R 1 Re Power 1 w Series 20 valve terminal B R R Rc joined by jumper Y Series 20 valve terminal W Y Compressor contactor Cc 24VAC common 3 G Fan relay S1 Optional outdoor remote sensor Cc 24VAC common 3 s2 Optional outdoor remote sensor S1 Optional outdoor remote sensor 2H 2C System 1 transformer Y2 Cool relay 2 s2 Optional outdoor remote sensor w2 Heat relay 2 2H 2C System 2 transformers Y2 Cool relay 2 Re Power 1 w2 Heat relay 2 R R Rc joined by jumper Re Power cooling transformer 1 2 w Heat relay 1 R Power heating transformer 1 2 Y Cool relay 1 wW Heat relay 1 G Fan relay Y Cool relay 1 Cc 24VAC common 3 G Fan relay S1 Optional outdoor remote sensor Cc 24VAC common 3 4 s2 Optional outdoor remote sensor S1 Optional outdoor remote sensor S2 Optional outdoor remote sensor See notes below 1
27. oor sensor required Recommended for most compressors Other options 1 2 4 5 or 6 CPH Recommended for most compressors Other options 1 2 4 5 or 6 CPH Continued on next page Installation Guide Installer setup Setup functions Settings Options factory default in bold Shaded areas below apply only to TH8320 TH8321 0240 0250 0260 0270 0280 0300 0310 0320 0330 0340 0350 0360 0380 First stage heat cycle rate CPH cycles per hour Second stage heat cycle rate CPH Third stage heat cycle rate CPH Emergency heat cycle rate CPH Backlight Manual Auto changeover Auto changeover deadband Temperature display Daylight savings Remote sensor Heat pump compressor lockout Heat pump auxiliary lockout Dehumidification control au 0 ow a ou 0 auw o 20 Gas or oil furnaces of less than 90 efficiency Steam or gravity systems Hot water systems amp furnaces of 90 efficiency Electric furnaces Other options 2 4 6 7 8 10 11 12 CPH Gas or oil furnaces of less than 90 efficiency Steam or gravity systems Hot water systems amp furnaces of 90 efficiency Electric furnaces Other options 2 4 6 7 8 10 11 12 CPH Electric auxiliary heat or electric furnaces Steam or gravity systems Hot water systems amp furnaces of 90 efficiency Gas or oil furnaces of less than 90 efficiency Other options 2 4 6 7 8 10 11
28. or y la inferior de la placa termostato de montaje y hale para separarla del termostato 2 Monte el termostato como se muestra a continuaci n Orificios de taladro de 3 16 para mamposter a en seco Orificios de taladro de 7 32 para yeso Tornillos de montaje Soportes de pared SD0O00VS0 Mes b Debe instalarlo un t cnico capacitado y con experiencia e Lea atentamente estas instrucciones Si las ignora podr a da arse el producto o generarse condiciones de peligro PRECAUCI N PELIGRO EL CTRICO A Puede causar descarga el ctrica o da o del equipo Desconecte la alimentaci n de energ a antes de iniciar la instalaci n AVISO DE MERCURIO Si este producto reemplaza a un control que contiene mercurio en un tubo sellado no arroje el control viejo a la basura Comun quese con la autoridad local de disposici n de desechos para recibir instrucciones sobre reciclado y eliminaci n correcta 2 VisionPRO TH8000 Serie Opciones de alimentaci n de energ a HEAT PUMP CONVENTIONAL Para la alimentaci n de energ a primaria 24VCA Conectar el lado com n del Inserte las bater as provistas para alimentaci n transformador al terminal C de energ a primaria o de respaldo
29. perature e 0 to 120 F 18 to 48 9 C Shipping Temperature e 30 to 150 F 34 to 66 C Operating Relative Humidity e 5 to 90 non condensing Physical Dimensions e 4 9 16 H x 6 W x 1 3 8 D e 116mm H x 152 mm W x 35 mm D Electrical Ratings Terminal Voltage 50 60Hz W Heating 20 30 Vac Powerpile 750 mV DC W2 Heating 20 30 Vac Y Cooling 20 30 Vac Y2 Cooling 20 30 Vac Aux Auxiliary heat 20 30 Vac O B Changeover 20 30 Vac E Emergency heat 20 30 Vac L Heat pump reset 20 30 Vac Need Help For assistance with this product please visit http yourhome honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Running Current 0 02 1 0A 100 mA DC 0 02 0 6 A 0 02 1 0A 0 02 0 6 A 0 02 1 0A 0 02 0 6 A 0 02 1 0A 0 02 0 6 A Honeywell Limited Honeywell Limit e 35 Dynamic Drive Toronto Ontario M1V 4Z9 http yourhome honeywell com Printed in U S A on recycled paper containing at least 10 post consumer paper fibers U S Registered Trademark Honeywell US Patent No 6595430 D509151 and other patents pending 2007 Honeywell International Inc 69 1896ES 1 M S Rev 02 07 mre Honeywell Guia de instalacion VisionPRO TH8000 Serie Termostato programable con pantalla activada por tacto ENERGY STAR Este manual cubre los siguientes
30. raci n del instalador Funci n Ajustes y opciones configuraci n de f brica en negritas Las reas sombreadas corresponden nicamente al modelo TH8320 TH8321 0240 0250 0260 0270 0280 0300 0310 0320 0330 0340 0350 0360 0380 Frecuencia del ciclo de calefacci n de primera etapa CPH ciclos por hora Frecuencia del ciclo de calefacci n de segunda etapa CPH Frecuencia del ciclo de calefacci n de tercera etapa CPH Frecuencia del ciclo de calefacci n de emergencia CPH luminaci n posterior Cambio Manual Auto Banda muerta del cambio autom tico Pantalla de temperatura Ahorro diurno Sensor remoto Cierre del compresor de la bomba de calefacci n Cierre de la bomba de calefacci n auxiliar Control de deshumidificaci n 5 1 3 9 awo ono w o O 0N0 O Para estufas de gas o petr leo con menos de 90 de eficiencia Para sistemas de vapor o gravedad Sistemas de agua caliente y estufas de 90 de eficiencia Estufas el ctricas Otras opciones 2 4 6 7 8 10 11 12 CPH Para estufas de gas o petr leo con menos de 90 de eficiencia Para sistemas de vapor o gravedad Sistemas de agua caliente y estufas de 90 de eficiencia Estufas el ctricas Otras opciones 2 4 6 7 8 10 11 12 CPH Calefacci n el ctrica auxiliar o estufas el ctricas Sistemas de vapor o gravedad Sistemas de agua caliente y estufas de 90
31. rie Funciones especiales Las reas sombreadas corresponden nicamente al modelo TH8320 TH8321 Cambio autom tico Funci n de configuraci n 0300 Cuando el sistema se fija en Auto el termostato selecciona autom ticamente calefacci n o refrigeraci n de acuerdo a la temperatura del interior Los ajustes de calor y fr o deben tener un m nimo de separaci n de 2 grados Si la funci n 0380 se fija en On los ajustes de calefacci n y refrigeraci n deber n tener un m nimo de separaci n de 5 grados Sensor remoto Funci n de configuraci n 0340 Si hay un sensor exterior opcional instalado el termostato puede mostrar la temperatura del exterior Si hay un sensor interior opcional instalado el termostato mostrar la temperatura que se registra en la ubicaci n del sensor no se utiliza el sensor interno del termostato Adaptive Intelligent Recovery Funci n de configuraci n 0530 Permite que el termostato aprenda cu nto tiempo les lleva a la estufa y al acondicionador de aire alcanzar la temperatura programada de modo que se alcance la temperatura a la hora fijada Protecci n del compresor Funci n de configuraci n 0580 Fuerza al compresor a esperar unos minutos antes de volver a encenderse para prevenir da os Durante este tiempo el mensaje Wait titila en la pantalla Control de deshumidificaci n Funci n de configuraci n 0380 Los modelos TH8321 controlan el nivel de humedad del interior y activ
32. tection is bypassed A during testing To prevent equipment damage avoid cycling the compressor quickly 10 VisionPRO TH8000 Series Special functions Shaded areas below apply only to TH8320 TH8321 Auto Changeover Setup Function 0300 When set to Auto the thermostat automatically selects heating or cooling depending on the indoor temperature Heat and cool settings must be at least 2 de grees apart If function 0380 is set to On the heat and cool settings must be at least 5 degrees apart Remote Sensor Setup Function 0340 If an optional outdoor sensor is installed the thermostat can display the outside temperature If an optional remote indoor sensor is installed the thermostat will display the temperature at the sensor location the internal sensor in the thermostat is not used Adaptive Intelligent Recovery Setup Function 0530 Allows the thermostat to learn how long the furnace and air conditioner take to reach programmed temperature settings so the temperature is reached at the scheduled time Compressor Protection Setup Function 0580 Forces the compressor to wait a few minutes before restarting to prevent damage During this time the message Wait flashes on the display Dehumidification control Setup Function 0380 TH8321 models monitor the indoor humidity level and automatically activate the cooling system to reduce humidity by lowering the temperature by up to 3 degrees below the current coo