1. M20575 Fig 7 Illustrated Parts List 7 68 0263 2 Honeywell Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley MN 55422 68 0263 2 GH Rev 4 04 Honeywell Limited Honeywell Limit e 35 Dynamic Drive Scarborough Ontario MIV 4Z9 Printed in U S A on recycled amp paper containing at least 10 post consumer paper fibers www honeywell com yourhome
2. STARTUP AND CHECKOUT After the Whole House Light Commercial HEPA System is 4 Verify that the Whole House Light Commercial HEPA installed with the ductwork in place and the unit plugged into Air Cleaner turned on a correctly grounded outlet 1 Be sure filters are installed in correct locations and ori ented correctly Note the air flow direction arrows on TRO U B L E S HO OTING the prefilter and the HEPA filter 2 Turn the On Off switch to the On position 3 If interconnected to the HVAC system blower turn on the system blower See Table 3 for troubleshooting guide Table 3 Troubleshooting Guide Symptom Cause Solution Poor airflow Filters plugged Remove and replace filter s Maintain filters at regular intervals Poor power supply at the site Have electrician check supply voltage at outlet Ductwork is restricting airflow Check duct installation AIRWATCH beeping Battery or filter needs replacing Observe which LCD is flashing and or flashing Replace the battery or filter as indicated 68 0263 2 6 F500 WHOLE HOUSE LIGHT COMMERCIAL HEPA FILTRATION SYSTEM PARTS LIST See Table 4 and Fig 7 for Parts List Table 4 Parts List Illustrated Parts List No Part Number Description 1 3200501 2 001 HEPA AIRWATCH Indicator 2 32006670 001 Blower Motor Assembly 3 32006026 001 Carbon Odor Filter 4 32006027 001 Pleated Prefilter 5 32006028 001 HEPA Filter
3. x 10 in hole in the desired loca tion and block off the old hole Reattach the duct flange over the new hole A transition can be used to connect round ducting to the Whole House Light Commercial HEPA System Keep duct sizes as large as possible throughout the installation 8 in minimum diameter ducting is recom mended Keep intake and exhaust duct runs as short as possi ble with few bends or elbows The F500 can be installed with a heat recovery ventilator See Fig 4 120 VAC 60 HZ SUPPLY WITH GROUND 688A1007 SAIL SWITCH OPTIONAL AIR HANDLER FURNACE HIGH EFFICIENCY AIR CLEANER M20263A Fig 2 Typical F500 bypass installation 120 VAC 60 HZ SUPPLY WITH GROUND A M20579 Fig 3 Typical F500 independent installation 68 0263 2 F500 WHOLE HOUSE LIGHT COMMERCIAL HEPA FILTRATION SYSTEM 120 VAC 60 HZ SUPPLY WITH GROUND S688A1007 ie SWITCH OPTIONAL FRESH AIR RECOVERY VENTILATOR AIR HANDLER FURNACE HIGH EFFICIENCY AIR CLEANER M20264A Fig 4 Typical F500 bypass installation with heat recovery ventilator INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow these instructions could damage the product or cause a haz ardous condition 2 Check the ratings on the product to make sure the prod uct is suitable for your application 3 Installer must be a trained ex
4. HEPA FILTRATION SYSTEM Table 1 Replacement Media Recommendations Replacement Interval Filter in in Part Number Normal Light Duty Carbon Odor Filter 24 x 12 32006026 001 3 months 4 months Pleated Prefilter 24 x 12 x 2 32006027 001 12 months 16 months HEPA Filter 24 x 12 32006028 001 3 years 5 years PLANNING THE INSTALLATION Selecting Mounting Position and Location The F500 can be suspended from exposed ceiling joists or the ceiling surface or it can be floor mounted 1 Install the F500A in a conditioned space or the F500B in an unconditioned space using these guidelines 2 Plan the unit location to minimize duct lengths 3 Locate an existing electrical outlet with the appropriate current rating to plug in the power cord If an outlet is not available have a qualified electrician install one 4 Choose a location that is readily accessible for checking and replacing the filter Allow at least 26 1 2 in 673 mm clearance in front of the unit Planning Ducting The F500 can be mounted to the whole house forced air system using a bypass configuration or can be independently ducted to stand alone See Fig 2 3 and 4 for typical installations e The Whole House Light Commercial HEPA air cleaner has 4 in x 10 in duct flanges to easily attach the external ductwork The intake port can be moved to a more convenient location if necessary Simply cut a new 4 in
5. Honeywell F500 Whole House ht Commercial HEPA Filtration System APPLICATION The F500 Whole House Light Commercial HEPA Air Cleaner connects to the return air duct of a forced air system The HEPA filter captures 99 97percent of the particles from the air that passes through it U S Registered Trademark Copyright 2004 Honeywell All Rights Reserved PRODUCT DATA OWNER S GUIDE FEATURES HEPA media captures at least 99 97 percent of 0 3 micron particles that pass through it Application for forced air systems Power cord plugs into grounded 120 Vac electrical outlet Requires no maintenance except periodic media filter replacement e Quick and easy media filter replacement Wall mounted AIRWATCH Indicator included provides filter change reminders Three filter system Activated carbon filter for odors High efficiency pleated pre filter extends HEPA fil ter life HEPA filter traps at least 99 97 percent of the 0 3 micron particles that pass through it Easy installation Includes four isolation straps Rugged steel cabinet Quiet operation Model available with fully insulated cabinet for installation in unconditioned environments Contents Application and Features eeseeesseseseeeeenereeeeneereneeees 1 Specifications 2 eeeeecececeeeeeeeeeeeeeeeeeeeeeeeeeeeeseneeeseneeeseeeeees 2 Ordering Information cccccccceeesceeeseeeeeneeessseessee
6. eess 2 Planning the Installation eeseeeseeeeeseeeeesseeeeeneeeeeaees 3 istallat aaae aaa aaaea 4 Startup and Checkout cccccccceeeeeeeeseeeeesneeeeseeeeeeneeeeees 6 TrOUDICSNOOTING 0 eee eeeeeeneeeeeneeeeeneeeeeeneeeeeneeeteeeeetenteneaes 6 Parts Listiiirde Acedia eea E EEEE 7 68 0263 2 F500 WHOLE HOUSE LIGHT COMMERCIAL HEPA FILTRATION SYSTEM SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances Therefore this unit may not exactly match the listed specifica tions Also this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed TRADELINE Models available F500 Whole House Light Commercial HEPA Filtration System includes HEPA filter 2 in pleated prefilter carbon odor filter and motor blower Isolation mounting straps and HEPA AIRWATCH Indicator are also included F500A Standard cabinet F500B Insulated cabinet Color White Dimensions See Fig 1 Electrical Ratings Input Power Requirements 120 Vac 60 Hz 1 98A maximum Air Flow F500A B 400 cfm nominal Efficiency Pleated Prefilter MERV 8 at 374 fpm HEPA Filter Media removes 99 97 percent of 0 3 micron parti cles from the air that pass through it Temperature Rating F500A is intended for mounting in conditioned spaces F500B cabinet allows ins
7. ervals Normal Factory Filter Setting Light Duty Carbon odor filter 3 months 4 months Pleated prefilter 12 months 16 months HEPA filter 3 years 5 years 7 Install two AAA alkaline batteries provided in the har ness on the back of the device 8 Observe that the device performs a self test beeping and flashing the LCD display 9 To start the timers press and hold the black reset button on the bottom of the device for five seconds or until the display stops flashing 10 Observe the battery LCD see Fig 5 a On solidly means the unit is correctly powered a Flashing indicates the battery requires replacing 11 Observe the AIRWATCH see Fig 6 a Beep every ten minutes when an LCD is flashing b Beeping indicates need to replace the system part that corresponds with the flashing LCD NOTES When batteries need replacing replace them within 30 seconds of removal to maintain the cor rect indicator time After 30 seconds of replacing the batteries if the LCD is blank remove and install new batteries When replacing other parts press and hold the black button on the bottom of the device to reset the timer after replacing the parts AIRWATCH On Battery Odor Filter Prefilter HEPA Filter Whole House HEPA Filtration System Honeywell com yourhome M20580 Fig 6 HEPA AIRWATCH Indicator 68 0263 2 F500 WHOLE HOUSE LIGHT COMMERCIAL HEPA FILTRATION SYSTEM
8. imply plug the air cleaner into a 120 Vac outlet The unit turns on and operates continuously when the power switch is turned on Torun the air cleaner only when the system blower is on use an optional Honeywell S688A1007 Sail Switch in the return air duct See the S688A product literature for correct installation procedures ON OFF DOOR SWITCH INTERLOCK FAN MOTOR POWER CORD 1 CAPACITOR TERMINAL BLOCK M20265 Fig 5 F500 internal wiring diagram F500 WHOLE HOUSE LIGHT COMMERCIAL HEPA FILTRATION SYSTEM Installing HEPA AIRWATCH Indicator Mount the HEPA AIRWATCH Indicator next to the thermostat or in any other convenient location in the home living area The battery operated device has no external electrical requirements 1 Remove the AIRWATCH Indicator from the base a Press the tab on the bottom edge of the base b Pull off the bottom of the front cover 2 Position the base on the wall in the desired mounting position 3 Using the holes in the base as a template mark the locations for the anchors and screws provided 4 Drill the holes 3 16 in and install the screw anchors provided 5 Position the base over the holes and install the screws to firmly secure the base to the wall NOTE Jumper is factory installed on pins 1 and 2 for normal usage 6 Move the jumper to pins 2 and 3 if desired for light duty filter change intervals as shown in Table 2 Table 2 Filter Change Int
9. perienced service techni cian 4 After installation is complete check out product opera tion as provided in these instructions Unpacking Whole House Light Commercial HEPA Filtration System The Whole House Light Commercial HEPA Filtration System is shipped fully assembled Check that all the components are included The carton contains the following e 500A or F500B Whole House Light Commercial HEPA Filtration System Activated carbon odor filter pleated prefilter HEPA filter HEPA AIRWATCH Indicator Four isolation mounting straps Literature 68 0263 2 4 maong and Ducting Mount four vibration isolation straps to the side of the HEPA System using the mounting screws located on the cabinet 2 Securely fasten the other ends of the straps to the floor joists with wide head nails or screws not supplied be sure the unit is level 3 Connect the HEPA System to the return air duct See Fig 1 and 2 Seal all duct joints with caulk mastic or high quality foil duct tape Installing Whole House Light Commercial HEPA Filtration System Electrical Connections The F500 has a 3 prong 120 Vac connector plug with ground If further wiring is required contact a qualified electrician to make all electrical connections IMPORTANT Be sure the unit is grounded correctly The F500 can be installed either to run continuously or to run only when the HVAC system blower is operating e Torun the air cleaner continuously s
10. tallation outside of conditioned space Approvals CSA Included Accessories HEPA AirWatch Indicator Four isolation mounting straps Replacement Media For optimum system performance replace filters according to Table 1 Use the HEPA AIRWATCH Indicator to deter mine when it is time to change each filter MOUNTING STRAP it 25 1 2 648 Honeywell ri envirac fe Whole House HEPA Fil ystem PROVIDE 26 1 2 673 SERVICE CLEARANCE IN FRONT OF UNIT Mi M20574 Fig 1 F500 dimensions ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor refer to the TRADELINE Catalog or price sheets for complete ordering number If you have additional questions need further information or would like to comment on our products or services please write or phone 1 Your local Automation and Control Solutions Sales Office check white pages of your phone directory 2 Honeywell Customer Relations 1885 Douglas Drive North MN10 1461 Minneapolis Minnesota 55422 4386 In Canada Honeywell Limited Honeywell Limit e 35 Dynamic Drive Scarborough Ontario M1V 429 International Sales and Service Offices in all principal cities of the world Manufacturing in Australia Canada Finland France Germany Japan Mexico Netherlands Spain Taiwan United Kingdom U S A 68 0263 2 2 F500 WHOLE HOUSE LIGHT COMMERCIAL