Heath Zenith 52-4076 User's Manual
Contents
1. Move PTE on wait 1 minutes the sensor head up down or O Turnthe SENSITIVITY SENS control to the mid posi sideways to change the cover tion and the ON TIME control to the TEST position age area Keep the sensor at least 1 2 5 cm away from Aim Sensor the lamps Down for Short O Adjust the SENSITIVITY Coverage SENS as needed Too much ON TIME j sensitivity may increase false 4m i triggering O Secure the sensor head Aim Sensor 10 5 1 TEST MIN MAX by tightening the clamp Higher for Long screw Do not overtighten the Coverage screw Bottom of Sensor O Set the amount of TIME you want the lights to stay on after motion is detected 1 5 or 10 minutes Avoid aiming the control at Warning Risk of fire Do not aim the lamps at a combustible surface within 3 ft 1 m Objects that change temperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light S P ECI FI CATIO N S e may trigger the shut off feature Do not point other Range Up to 60 ft 18 3 m varies with lights at the sensor surrounding temperature Sensing Angle Up to 110 Electrical Load Up to 300 Watt Maximum In candescent Up to 150 Watt 110 maximum each lamp holder e
2. joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done WIRE THE LIGHT CONTROL O Turn power off at the fuse or circuit breaker O Remove the existing light fixture O Route the Light Control s wires through the large gasket hole O Connect the junction box wires to the Light Control wires Twist together and secure with a wire connector White to White Gasket Mount THE LIGHT CONTROL El Align the Light Control cover plate and the junction box holes Secure with the mounting screws O Ifnotinstalled on a weatherproof box or if an adaptor plate not included was used caulk the wall plate and mounting surface with silicone Avoid water damage and electrical shock keep lamp holders below horizontal Lock nuts CY LL Keep lamps at least 1 25 mm from the sensor O Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180 from the factory setting When screwing in the flood lamps do not overtighten 598 1284 00 TEST AND ADJUSTMENT 2 Loosentheclampscrewin the Clamp sensor ball joint and gently Screw O Turn on the circuit breaker and light switch rotate the sensor s4 NOTE Sensor has a 1 2 minute warm up period Re a Bal t before it will detect motion When first turned g y om when the lights turn on
3. les porte lampes 598 1284 00 ESSAIS ET REGLAGES O Mettre en circuit le disjoncteur et l interrupteur d clairage NOTE Lecapteurdoitse r chauffer 1 2minute avant de pouvoir d tecter le mouvement Lorsque l appareil est mis en circuit attendre 1 2 minute O Tourner la commande de sensibilit SENS la position interm diaire et la commande de temps en circuit ON TIME a TEST ON TIME SENS i to MIN MAX 10 51TEST Bas du d tecteur viter de pointer l appareil en direction d objets dontla temp rature change rapidement tels que des bouches d air chaud et des climatiseurs De telles sources de chaleur peuvent provoquer des d clenche ments intempestifs vers des endroits o des animaux des v hicules ou des passants peuvent d clencher la commande sur de grands objets clairs a proximit qui r fl chissent la lumi re du jour et risquent de d clencher le dispositif d arr t Ne pas pointer d autres appareils d clairage vers le d tecteur 10 2 4m 18 3 m Port e maximale Angle de couverture maximale Le d tecteur est moins sensible au mouvement dans sa direction Mouvement Mouvement D tecteur Le moins sensible Le plus sensible 598 1284 00 O Desserrer la vis de blocage Vis de de la rotule et faire pivoter le E blocage d tecteur pour pointer C a O Marcher dans la zone de Rot
4. pendant une seconde plus en circuit 1 Second OFF pour alterner entre les modes AUTO then et MANUEL Le mode manuel ne fonctionne qu avec l interrupteur ON TIME aux positions 1 5 ou 10 back on R sum du mode de commutation Placer l interrupteur ON TIME a 1 5 ou 10 minutes Mettre l interrupteur hors circuit pendant z une seconde puis le PRIORITE MANUELLE remettre en circuit Si vous ne savez plus dans quel mode se trouve l appareil couper l alimentation pendant une minute puis la r tablir Apr s le temps d talonnage la commande reviendra au mode AUTO 598 1284 00 F INSTALLATION Pour faciliter l installation choisir un appareil d clairage devant tre remplac et qui est d j command par un interrupteur Pour assurer un rendement maximal monter l appareil d clairage environ 2 4 m tres au dessus du sol O Percez les trous n cessaires au montage de la plaque ar ri re la bo te de jonc tion Montage sous avant toit Montage mural Pour viter le risque de choc lectrique les commandes du d tecteur doivent tre tourn es vers le bas Pour montage sous avant toit seulement O Faire pivoter la t te du d tecteur en direction du joint a vis de blocage Commandes Vis De Blocage O Puis faire pivoter le d tecteur sur 180 de fa on que les commandes soient tourn es vers le bas Si le d tecte
5. qualifi Veuillez v rifier les codes en vigueur dans votre r gion Ce produit est con u pour tre utilis avec une bo te de jonction portantune indication d utilisation possible en milieu humide Pour votre commodit la plaque arri re est maintenant pourvue de trous d bouchures pour que l appareil puisse facilement tre mont sur presque n importe quelle bo te de jonction Pour certaines applications une plaque d adaptation universelle peut tre n cessaire On peut se procurer ces plaques d adaptation dans des centres de r novation domiciliaire et magasins de fournitures lectriques FONCTIONNEMENT Temps en circuit Mode Essal Auto Manuel En fonction Jour Nuit 5 secondes X X 1 5 ou 10 min X au choix x amanecer Revient au mode automatique au lever du soleil Note Apr s mise en circuit attendre enfiron 1 2 minute pour que l talonnage du circuit soit compl t ESSAI Amener en position d essai TEST ON TIME l interrupteur de temps en circuit ON TIME du bas du d tecteur 1051TEST AUTOMATIQUE Amener l interrupteur de temps en ON TIME circuit ON TIME a la position cor ells respondant a 1 5 ou 10 minutes 10 5 1 TEST PRIORIT MANUELLE Le mode manuel ne fonctionne que la nuit parce que la lumi re du jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit
6. tecteur ou des objets rapproch s La chaleur r fl chie parles objets en vironnants peut affecter le d tecteur Repositionnez le d tecteur La commande est en mode test et se r chauffe Le clignotement est normal dans ces conditions La lumi re peut filtrer travers les r flecteurs des projecteurs Remplacezles projecteurs par des projecteurs neufs PAR 38 de haute qualit Aucune pi ce de rechange n est disponible pour ce produit 598 1284 00
7. N TIME switch in the 1 5 or 10 minute position EX V 1051TEST MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO Fa Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE 1 Second OFF then Manual mode works only with the ON TIME switch in the 1 5 or 10 position EI back on Mode Switching Summary Move ON TIME Switch to 1 5 or 10 minutes Flip light switch off for one second then back on MANUAL MODE If you get confused while switching modes turn the power off for one minute then back on After the cali bration time the control will be in the AUTO mode 598 1284 00 INSTALLATION For easy installation select an existing light operated by a wall switch for replacement For best performance mountthe fixture about 8 feet 2 4 m above the ground O Drill the holes needed to mount the backplate to the junction box Wall Mount Eave Mount For under eave installation the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock For eave mount only O Rotate the sensor head towards the clamp screw joint Control Switch Joint Clamp O Then rotate the sensor head clockwise 180 so the controls face down LS If the sensor pops out of the ball
8. NOMA Security Light with Motion activated Sensor Cr Models 52 4075 52 4076 This product is ENERGY STAR compliant when used with 120 Watt bulbs Installation and Operating Instructions Features e Turns on lighting when motion is detected e Automatically turns lighting off Photocell keeps the lighting off during daylight hours This package includes Lamp Holders Cover Plate 4 Mounting N Screws 2 sizes oy Sensor Gasket 2 Wire Light Control Connectors Requirements The Light Control requires 120 volts AC If you want to use Manual Mode the control must be wired through a switch Some codes require installation by a qualified elec trician Please check the codes in your area This product is intended for use with a junction box marked for use in wet locations The backplate has knockouts so the sensor can be mounted on most junction boxes In some applications a universal adaptor plate may be needed Adaptors are available at home centers and electrical supply stores OPERATION On Time 5 Sec 1 5 10 min Until Dawn resets to Auto Mode at dawn Mode Test Normal Manual Works Day Note When first turned on wait about 1 2 minutes for the circuitry to calibrate TEST Put the ON TIME switch on the bottom of the sensor in the TEST position ON TIME J 10 5 1 TEST AUTO ON TIME Put the O
9. SE POSSIBLE Linterrupteur d clairage est hors tension Le projecteur est d viss ou br l Lefusible a saut oule disjoncteur a t d clench Le dispositif de coupure pendant le jour fonctionne V rifiez nouveau la noirceur Mauvais c blage du circuit dansle cas d une nouvelle installation R orientezle capteur pour couvrir la zone d sir e La commande peut tre install e dans un endroit relativement sombre La commande est en mode TEST Placez l interrupteur de la commande une postion ON TIME La commande peut d tecter de petits animaux oula circulation auto mobile R orientez le d tecteur Le r glage de port e est trop lev R duisez la port e SYMPT ME L clairage reste allum continuel lement L clairage cli gnote CAUSE POSSIBLE Un projecteur est situ trop pr s du d tecteur ou point vers des objets etla chaleur d clenche le d tecteur Repositionnez le projecteur loin du d tecteur ou des objets rappro ch s Lacommande d clairage est point e vers une source de chaleur comme un vent une sortie de s cheuse ou une surface claire qui r fl chit la cha leur Repositionnez le d tecteur Lacommanded clairageestenmode manuel Mettez la en mode auto La chaleur ou l clairage des pro jecteurs peut teindre et allumer la commande d clairage Reposi tionnezles lampes loin du d
10. is in Manual Mode Switch to Auto Heat or light from the lamps may be turning the Light Control on and off Reposition the lamps away from the sensor Heatbeing reflected from other objects may be affecting the sensor Reposi tion sensor Light Control is in the Test mode and warming up Flashing is normal under these conditions Light may be leaking through the floodlamp reflectors Replace the lamps with new high quality PAR 38 lamps No Service Parts Available for this Product 598 1284 00 NOMA Lampe de s curit d tecteur de mouvement Ce produit est conforme ENERGY STAR lorsqu il est utilis avec des ampoules de 120 watts Mod les 52 4075 52 4076 Instructions d installation et mode d emploi Caract ristiques e Allume l clairage lorsqu un mouvement est d tect e teint automatiquement l clairage e Photocellule qui maintient l clairage teint pendant la p riode de lumi re du jour Cet emballage comprend Douilles de lampe Plaque de garde 4 vis incluses 2 formats D tecteur Garniture DO de joint m m Commande CIS d clairage 2 serre fils Exigences La commande d clairage n cessite une alimentation de 120 V c a Pour utiliser la priorit manuelle raccorder la com mande un interrupteur Certains codes de b timent locaux peuvent ex iger que l installation soit faite par un lectricien
11. s pe m Power Requirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE 60 ft Time Delay 1 5 10 minutes 18 3 m Range Adjustable Maximum Range Maximum Coverage Angle The detector is most sensitive to motion across its field of view Sie Least Sensitive Most Sensitive 598 1284 00 3 TROUBLESHOOTING Lights willnotcome on Lights come on in daylight Lights come on for no apparent reason i EA switch is turned off Flood light is loose or burned out Fuse is blown or circuit breaker is turned off Daylight turn off is in effect re check after dark Incorrect circuit wiring if this is a new installation Re aim the sensor to cover de sired area Light Control may be installed in a relatively dark location Light Control is in Test Set control switch to an ON TIME position Light Control may be sensing small animals or automobile traf fic re aim sensor Sensitivity is settoo high Reduce sensitivity POSSIBLE CAUSE Lights stay on continuously Lights flash on and off A flood lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor Reposition the lamp away from the sensor or nearby objects Light Control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective sur face Reposition sensor Light Control
12. ule couverture et noter a quel en droit l clairage se d clenche D placer la t te du d tecteur vers le haut le bas ou le c t pour modifier la zone de couverture Ne pas permettre au d tecteur d tre moins de 25 mm des lampes O R glerlasensibilit SENSITIV ITY selon les besoins Une trop grande sensibilit pourrait Pointer le d tecteur vers le bas pour r duire la couverture causer des d clenchements Pointer le intempestifs d tecteur vers O Fixer la t te du d tecteur en le haut pour position en serrant la vis de augmenter la blocage viter de trop serrer couverture la vis g Placer l interrupteur ON TIME 1 5 ou 10 minutes Avertissement Risque d incendie Ne pas pointer les lampes vers une surface combustible situ e moins de 1 m tre FICHE TECHNIQUE Jusqu 18 3 m 60 pi Varie selon la temp rature ambi ante Jusqu a 110 Jusqu a deux ampoules incandescentes pour un maximum de 300 W maxi mum de 150 W par sup port 120 V CA 60 Hz Angle de d tection Charge lectrique Alimentation lectrique Modes de fonctionnement Essai automatique et priorit manuelle D lais 0 1 5 et 10 minutes Port e R glable SYMPTOME L clairage ne s al lume pas L clairage s allume en plein jour L clairage s al lume sans raison apparenie DEPANNAGE CAU
13. ur sort de la rotule desserrer la vis de blocage et r ins rer le d tecteur dans la rotule et resserrer la vis C BLAGE DE LA COMMANDE D ECLAIRAGE Couper l alimentation du circuit d clairage au fusible ou au disjoncteur Enlever l appareil d clairage existant Faire passer les fils de la commande d clairage par le trou de la garniture Torsader les fils de la bo te de jonction avec ceux de la commande d clairage Les fixer ensemble a l aide de serre fils noir noir O OO blanc blanc MONTAGE DE LA COMMANDE D ECLAIRAGE O Aligner la plaque de garde de la commande d clairage et le joint a la plaque d adaptation s il y a lieu avec la bo te de jonction Ins rer et serrer les vis de montage O Sielle n est pas mont e dans un bo ter tanche ou si une plaque d adaptation est utilis e calfeutrer la plaque murale et la surface de montage avec un scellant au silicone Pour viter les dommages par l eau et lesrisquesdechoc lectrique s assurer que les douilles de lampe pointent en dessous de l horizontale Ajusterles douilles de fa on que les lampes se trouvent au moins 25 mm du d tecteur Contre crous O Ajusterles porte lampes en desserrantles crous de blocage mais ne pas faire tourner les porte lampes de plus de 180 par rapport au r glage d usine Ne pas trop serrer les lampes dans