Home
Hasselblad Flextight 343 User's Manual
Contents
1. 36 x 24 60 x 60 60 x 90 60 x 120 Table 1 True Optical Resolutions To avoid activating the resizer select a zoom setting that gives one of the results listed in Table 1 When resizing is applied the scans take longer and image quality is slightly reduced The impact on the image quality will vary according to the amount of interpolation required and the contents of your original User s Guide Flextight 343 Hardware Reference Flextight 343 Resolutions 15 Example For an output resolution of 300 ppi take the true resolution shown in Table 1 divide by 300 and multiply by 100 Enter the result in the Zoom field in the main FlexColor window Zoom Setting Original Max A Resolution 3200 gt x100 24 x 36 300 1067 36 x 24 1067 60 x 60 1067 60 x 90 1067 60 x 120 1067 Table 2 Zoom settings for true optical resolution at 300 ppi output Note that when the Zoom field is set to an appropriate value for the selected original size as shown in the table above then the PPI pop up menu shows an underline beneath each setting that will result in a scan taken with a true resolution no interpolation LA A m E Cone Other Ee Width Height Le 200 Zoom 267 PPI v 300 Size 400 533 m Zoom 600 as soo 8 1000 Orient 1067 e 1200 1500 Soft 1600 2000 3000 3200 User s Gu
2. Environmental Requirements Set up the scanner in a location that fulfils the following requirements e Keep the scanner away from sources of heat such as direct sunlight or a radiator Warm temperatures will degrade the quality of your scans for best results work in a cool environment e The scanner must be operated away from sources of strong electromagnetic interference Although the scanner complies with all regulations governing electromagnetic immunity and Hasselblad has taken every reasonable step to make the unit immune to electromagnetic interference it is still a precision electronic device so strong radio waves can interfere with your scans e The surface on which the scanner is placed must be stable and free from vibrations If the scanner is shaken or moved while scanning your results may be affected e If the scanner has been in a colder environment e g outside or in storage just before you set it up in a warmer room then wait about two hours before using it otherwise condensation may form which will prevent the scanner from operating correctly e Avoid using the scanner in areas where there is a high level of dust e To prevent dust from getting into the scanner always close the feed table when the scanner is not in use Electrical Requirements The Flextight 343 power supply requires a mains voltage of between 100 and 240 V AC at a frequency of 50 to 60 Hz This is within the normal wall socket power st
3. User s Guide Flextight 343 2004 Hasselblad A S All rights reserved Flextight 343 User s Guide Part No 70030051 revision A The information in this manual is furnished for informational use only is subject to change without notice and should not be construed as a commitment by Hasselblad A S Hasselblad A S assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual Hasselblad A S assumes no responsibility or liability for loss or damage incurred during or as a result of using Hasselblad software or products Hasselblad Imacon FlexColor and Flextight are trademarks of Hasselblad A S Adobe and Adobe Photoshop are trademarks of Adobe Systems Inc Macintosh Mac OS FireWire and ColorSync are registered trademarks of Apple Computer Inc Printed in Denmark User s Guide Flextight 343 Table of Contents 3 Table of Contents Hardware Reference Flextight 343 5 Warnings and Restrictions 6 System Requirements 6 Front Panel 7 Back Panel amp Connectors 8 Cut Away View 9 Setting up the Scanner 10 Environmental Requirements 10 Electrical Requirements 10 Installation Procedure FireWire Interface 41 Operating the Scanner 13 Resolutions 14 True Optical Resolutions 14 The Light Tube 16 Orientation of the Light Tube 16 Replacing the Light Tube 17 Cleaning the External Surface of the Scanner 19 Disposal 19 Technical Specifications 20 FCC Notice 21 CE Declaration of
4. 10 25 C 50 77 F Relative Humidity 20 80 RH no condensation Storage Environment Temperature 0 50 C 32 122 F Relative humidity 20 80 RH no condensation Originals Transparencies from 35mm to 60x180 mm lt 1mm thick Light Tube OSRAM L6W 25 Universal White Dimensions Height 400 mm 15 7 Width 265 mm 10 4 Depth 245 mm 9 6 feed table closed 370 mm 14 6 feed table in scan position Weight 7 kg 15 5 Ibs User s Guide Flextight 343 Hardware Reference Flextight 343 FCC Notice 21 FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense User s Guide Flextight 343 22 Hardware Reference Flextight 343 CE Declaration of Conformity CE Declaration of Conformity HASSELBLAD HEIREVE 30 DK 2400 COPENHAGEN NV TELEPHONE 45 7026 0800 TELEFAX 4
5. 5 7026 0900 REGVAT No 18635445 www has sselblad com Declaration of conformity Application of Council Directives 89 336 EEC amended by 92 31 EEC 93 68 EEC 91 157 EEC C73 23 EEC amended by 93 68 EEC Standards to which Conformity is declared EN61000 6 1 2001 EN61000 6 3 2001 and EN60950 2000 Manufacturer Hasselblad A S Hejrevej 30 DK 2400 Copenhagen NV Denmark Type of Equipment cc eeeeesseseeeseees DeSktop CCD scanner Model name Flextight 343 The undersigned hereby declare that the equipment specified above conforms to the above Directives and Standards Place Copenhagen NV Date csccssic eusecccese September 12th 2004 Full name 0 Christian Poulsen POSITION ceeeee CEO Signatur User s Guide Flextight 343
6. Conformity 22 User s Guide Flextight 343 User s Guide Flextight 343 Hardware Reference Flextight 343 5 Hardware Reference Flextight 343 This manual provides important information about using your Flextight 343 scanner Topics include e Important warnings and restrictions e System requirements e Diagrams of the front panel rear panel and internal structure of the Flextight 343 scanner e Installation instructions Environmental requirements e Electrical requirements e Operating instructions e Maintenance advice e Disposal instructions e Technical specifications e Declarations of FCC and CE regulation conformity User s Guide Flextight 343 Hardware Reference Flextight 343 Warnings and Restrictions Warnings and Restrictions e Read all of the included documentation before attempting to install and use the scanner e Do not touch the originals and or the original holder while scanning e Do not start scanning or previewing until an original holder with an original has been mounted e The original holder is only to be mounted or removed when the drum is in the load position e When you turn on the scanner the drum will roll to the load position if it is not there already Do not touch the scanner while the drum is rotating e Do not place your fingers or any other object into the scanner while it is connected to power e Before servicing or opening the scanner the power su
7. andards of most countries Do not attempt to use Flextight 343 with any power source outside the specified range The scanner and all devices attached to the scanner computer monitor and FireWire devices etc must be grounded i e use a three point electrical connection Note that the power supply may emit a low hissing sound when plugged in but not connected to the scanner This is normal and will not damage the power supply or scanner User s Guide Flextight 343 Hardware Reference Flextight 343 Setting up the Scanner Installation Procedure FireWire Interface 1 Place the scanner on a table near your computer with the front facing away from you Make sure that the location you choose meets all environmental and electrical requirements as described on page 10 When using a FireWire interface connection it is not necessary to switch of your computer and other connected units Connect a FireWire cable from one of the FireWire connectors on your scanner see Back Panel amp Connectors on page 8 to either the computer s FireWire connector or to a free FireWire connector on any other FireWire device already connected to your computer Connect the round connector from your power supply to the round power supply socket on the back of the scanner IMPORTANT Make sure that the wall socket you are planning to use meets the electrical requirements outlined earlier Plug the Flextight 343 power supply into a wall
8. ealer or see specification in Technical Specifications on page 20 2 Turn off and unplug the scanner from the primary power supply 3 IMPORTANT Let the light tube cool down for app 10 minutes before proceeding 4 Lay the scanner down on its back with the bottom facing you 5 Usea2 5 mm allen key to remove the screws located at each of the four corners of the bottom panel see Figure 6 then remove the bottom panel Figure 6 To remove the bottom panel remove the four screws at the positions shown The numbers indicate the order in which they should be tightened when panel is replaced continues User s Guide Flextight 343 Hardware Reference Flextight 343 18 The Light Tube 6 The light tube is clearly visible as shown in Figure 7 Hold each end of the light tube between your thumb and index finger Rotate the light tube until it comes free and pull it away from the scanner Note that the light tube sockets allow the tube to be rotated all the way around but they click into position at each quarter turn The light tube is locked in place in all but one of these four positions so you may need to try up to three positions before the light tube comes free Feed Table closed The holes in the light tube sleeve must point forwards towards the feed table Light Tube Figure 7 Bottom view of the scanner with the bottom panel removed 7 Install a new light tube following the reve
9. gently into the original holder clasp H at the scanner entrance It will slip about cm 1 4 inch into it Do not press too hard It slips in very easily and is held in place by a pair of magnets To remove the holder simply pull it gently backwards Lift the magnetic layer C of the original holder and place your original E with the emulsion side up The original must completely fill the hole with no edges showing and with a minimum overlap of 2mm along each edge Also no edges of the original must extend past the outer edges of the holder Use the grid in the light area J of the feed table B to help line up the image Lay the top layer of the holder down flat over the original The top layer C is magnetic which will hold the original in place Go to your computer and follow the directions given in the FlexColor software manual to take a preview make settings and take the final scan User s Guide Flextight 343 13 Hardware Reference Flextight 343 Resolutions 14 Resolutions True Optical Resolutions The table below shows the true optical resolutions in ppi available with each of the original holders When scanning at one of the resolution settings listed one pixel in the scanner s image sensor corresponds exactly to one pixel in the final image If you use a resolution setting other than those listed then interpolation resizing must be applied a Resolutions PPI Original 24 x 36
10. ide Flextight 343 Hardware Reference Flextight 343 16 The Light Tube The Light Tube Orientation of the Light Tube Flextight 343 contains a light tube that illuminates your originals while scanning The light tube is fitted with a reflective sleeve which must be aligned correctly inside the scanner The sleeve helps direct the light to achieve maximum illumination of the original When you replace the light tube you must make sure the sleeve is aligned correctly Sometimes the sleeve is glued into place when the scanner is first shipped from the factory but when you replace a light tube the sleeve will not be glued it will be tight so that it can not slip freely but you will be able to rotate it manually if you try The correct orientation of the sleeve is shown in Figure 5 Illuminate original CCD Transmission Lamp Align the sleeve with the _ Illuminate pins as shown Note that Feed table the long top slot should line fried light area up between the two pins Figure 5 Light tube sleeve alignment as seen from the left side of the scanner User s Guide Flextight 343 Hardware Reference Flextight 343 The Light Tube 17 Replacing the Light Tube If your scans are suddenly coming out black or all white if you are scanning negatives then the light tube may be defective or misaligned Follow procedure below to replace a tube 1 Get the appropriate replacement light tube ask your Flextight d
11. ile the indicator is red If the light is flashing when not scanning then an error has occurred please contact your Flextight dealer for assistance Power Switch press to turn the unit on off Original Holder Clasp all original holders slide into a slot here and are held in place by magnets mo User s Guide Flextight 343 Hardware Reference Flextight 343 Back Panel amp Connectors Back Panel amp Connectors Figure 2 Back panel features of Flextight 343 A B Power Cable Socket plug the power cable into this socket FireWire Interface Sockets plug a FireWire cable max 6 m here and connect it to your computer You can use the second plug to connect another device hard disk printer etc to the FireWire chain User s Guide Flextight 343 Hardware Reference Flextight 343 Cut Away View Cut Away View imacon Figure 3 Cut away view of Flextight 343 A CCD Plate this platform contains the light sensor B Optics focuses the image of the original on the CCD C Drum rotates the original into the scanner and steps it past the CCD line of focus D Light Tube illuminates the transparent originals The tube also provides the light for the feed table Original Holder an original holder is shown mounted and with the magnetic top layer held open m User s Guide Flextight 343 Hardware Reference Flextight 343 Setting up the Scanner 10 Setting up the Scanner
12. pply must be disconnected from the mains unplugged It is not sufficient simply to press the on off button e Install the scanner in a location where children can not get to it It contains small openings and moving parts that can cause injury System Requirements Below are the basic hardware requirements for the PC or Macintosh system to which the scanner is to be connected For information about the processor operating system RAM and harddisk requirements please refer to the Software Reference manual that comes with the FlexColor software e Screen resolution of 800 x 600 pixels with true colors 24 bits e Mouse or other pointing device e FireWire interface User s Guide Flextight 343 Hardware Reference Flextight 343 Front Panel Front Panel Figure 1 Front panel features of Flextight 343 A Feed Table place original holders here for scanning The table can be folded up to keep dust from entering the scanner and to keep it out of the way B Light Area for viewing originals The grid helps you to align the originals C Indicator light The indicator can light up in 3 different colors indicating the following Green Power Ready remains lit when ready to scan Flashes when first installed to indicate that firmware must be loaded it will be loaded automatically when you run FlexColor Yellow Motor Drive when drum is repositioning Red Scanning when scanning Do not touch the scanner wh
13. rse of the procedure you used when removing it Make sure the sleeve is aligned correctly with the scanner as shown in Figure 5 Rotate the light tube and or adjust the sleeve as necessary 8 Replace the bottom panel by holding it in place and tightening the screws in an opposite diagonal sequence e g top left bottom right top right bottom left as indicated in Figure 6 9 Turn on the scanner and check function of the new tube User s Guide Flextight 343 Hardware Reference Flextight 343 Cleaning the External Surface of the Scanner 19 Cleaning the External Surface of the Scanner If the external surface of the scanner becomes dirty then clean it with a damp cloth Be careful not to get any moisture inside the scanner or on any of the connectors Do not use alcohol or other solvents Disposal If you need to dispose of the scanner it must be delivered to an authorized waste plant for electronics equipment User s Guide Flextight 343 Hardware Reference Flextight 343 Technical Specifications 20 Technical Specifications Power Connector 24 VDC 60W oe Power Consumption Max 60 W during operation Power Requirements 100 240V AC 1 3A 50 60Hz Interface to Computer FireWire IEEE 1394 Front Panel One multifunction switch on off switch and status light Drum Force 1kg 2 2Ibs Operating Environment Operating Temperature 10 35 C 50 95 F Recommended Working Temperature
14. socket Note that the power supply may emit a low buzzing sound when plugged in This is normal and will not damage the power supply or scanner Turn the scanner around so that the front is facing you Your system is assembled Turn on your computer and install the FlexColor image scanning software User s Guide Flextight 343 11 Hardware Reference Flextight 343 Operating the Scanner 12 Figure 4 Operating the Flextight 343 scanner User s Guide Flextight 343 Hardware Reference Flextight 343 Operating the Scanner Operating the Scanner See Figure 4 opposite 1 10 It is assumed that the scanner and FlexColor software have been properly installed Pull the feed table B down to scan position Press the power button G on the front of the scanner to switch it on The indicator light F button will start flashing green indicating that no firmware has been downloaded yet It will be downloaded automatically later when you first run the FlexColor program Turn on your computer and launch the FlexColor program The indicator light F will stop flashing indicating that firmware has been downloaded to the scanner Select the original holder D that matches your original Place the original holder with the slotted tab facing into the scanner The flexible magnetic layer C must face upwards and the holder must fit between the guides A on both sides of the feed table Slide the holder
Download Pdf Manuals
Related Search
Related Contents
Cables Direct B6LZ-602Y networking cable BETRIEBSANLEITUNG RESERVETEILKATALOG Samsung GT-S7250D Manuel de l'utilisateur South Shore Furniture 4079677 Instructions / Assembly News 7 - Hatier Perfection Professional Benutzer- handbuch LT80 (Page 2) 10 I Desmontaje del compresor - GEA インドの聖典 第一回 - バガヴァッド・ギーター勉強会 Copyright © All rights reserved.