Home
Haier Refrigerator HYC-260-360 User's Manual
Contents
1. Follow the instructions on the type plate The electrical plug should be kept clean avoid power leaks or electrical hazards Qualified technicians should carry out installation or maintenance as unauth Orized installation or repair may result in gas or liquid leaks electrical shocks or fires The appliance must be installed on a solid and flat surface or the appliance may fall or tilt Do not place the appliance in a damp area as wet insulating materials may cause electrical leaks or hazards and use a dedicated power source for the appliance as a power adaptor may cause fires and be tightly inserted into the socket or fires may result The electrical socket must be grounded by a qualified technician to avoid electrical shocks After installation the socket should be accessible Never ground the appliance to a gas or water pipe telephone line or lightning rod as such connection may result in electrical shocks Avoid accidental access of steel wires or conductive cables into the airflow openings to prevent electrical shocks and damage to the appliance 9S Never store volatile and or inflammable materials in the appliance Unplug the appliance before commencing repairs maintenance or inspection Do not pull out two drawers simultaneously when loading or unloading the appliance Do not store excessive weight in the drawers Do not sprinkle water directly on the appliance for cleaning to avoid e
2. all tightly sealed Lamp replacement The lamp is installed on the front top of the appliance and installation procedure is as follows ae oa a Unplug the appliance Hold the lamp holder and remove the lampshade Rotate to remove the lamp Replace with a new lamp Connect the appliance to a power source Caution Ensure that the specification of the new lamp complies with the requirements Starter replacement l 2 3 4 Unplug the appliance Remove the starter Tightly install the new starter Connect the appliance to the power source 11 Cautions The following procedures cover the operation of the appliance 1 The appliance should be connected to a dedicated socket for 220 V S50Hz power Battery supply Allow some time lapse before loading the appliance Lamp Control Samten switch pannel 2 The warning sound signal may be heard when the appliance is first connected to the power source and can be inactivated by pressing the buzzer buttom The warning indicator stays on until the temperature of the test bottle sensor reaches 5 C 2 C Inner light Haier 3 Ensure that the two test bottles are filled with 10 glycol solution see article 4 section installation on page 6 4 The appliance is preset during manufacture for operation temperature 2 8 C 5 A few hours after the appliance operates the desired temperature value will be attained After the temperature in the appliance is stable c
3. Haier Pharmaceutical Refrigerator Operation Manual HY C 260 360 Read the Operation Manual carefully before using your appliance Keep the Operation Manual in a safe place Appearance color and layout of the door may vary Contents Safety precautions ce cece cease l AOCOSSOTICS ic6nesnceessadeceescenasawnenvet 3 LOCAtION 0 ccc cece cece ence cece anes 5 Installation ccc ccc ce eee e ee cece ees 6 Operation instructions 66 7 Cautions ccc cece cece eee eeeeee ees 10 Maintenance and repair 11 Technical information 66 12 1 Full or partial copying or reproduction of the contents in this Operation Manual is not permitted without written consent from Haier 2 The edition of this manual for the appliance that you have just purchased may vary Design or layout of the appliance that you have just purchased may vary due to technical improvements Technical information Product Pharmaceutical Refrigerators Model HYC 260 HYC 360 Volume 260L 360L External panel Sprayed steel sheet Internal panel HIPS Door Glass door Insulation Styrene polyurethane foam Freon free Shelf Nn Cooling Air circulation Compressor Sealed Refrigerant R134a Thermostat Electronic control system Over temp warning Indicatoe blinks for buzzer and remote warning Low temp warning Indicator blinks without deferred buzzer alarm Door war
4. e appliance is first initiated it will take 2 days for the appliance to fully charge the batteries During the process of charging the batteries the remote warning contact is maintained in operational mode Warning test procedures Press Warning Test button If one press of the button results in 3 buzzes of 1Hz 3 flashes of the warning indicator and 3 operation cycles of the remote warning relay before disconnection the warning system is deemed to be in a normal state T Staff should be designated for daily inspection and record of the operation status of the appliance Items in storage should be moved to another appliance if temperature fluctuates abnormally Troubleshooting Desired temperature is not reached Appliance not placed on flat surface Excessive noise l i Appliance contacts other objects New items loaded while temperature is not at 2 8 C Warning indicator blinks with Door not tightly closed buzz Insufficient power supply Temperature exceeds designed degree Unit does not operate Operation Warning safety and detection This appliance has warning safety operation and detection functions Table 2 Warning and safety High temp Temperature detected by Warning indicator Pulse warning Remote warning upper or lower sensor 28 C blinks contact activated upper or lower sensor S2 C ois Temperature detected by Warning mode on Power interruption Door ajar Sensor back a
5. fter calibration Abnormal sensor sensor 8 Cor S2 C Power interruption or switch off External door ajar or open Control panel off control within 90 seconds Upper sensor open or short and no further instruction Warning indicator blinks temp display off Warning indicator blinks 1 min later Test bottle temp display Warning indicator blinks temp _ El Hi temp warning mode activated Pulse warning for lt 72h power interruption Pulse warning after Imin delay Not affected Calibration mode finishes Pulse warning Remote warning contact activated Defrosting circuit open or AA Oret temp sensor open shor le battery voltage Not low or abnormal Caution Remote warning contact and sound warning indicator can activated at the same time When the appliance warning mode is activated pressing the buzzer button will disconnect the remote warning contact When the power is interrupted the contact is in the warning mode until power interruption status is lifted All warning functions can reset automatically If warning status is not altered within 30 minutes the buzzer and remote control contact will be activated again Location The appliance should be located in an area where the following requirements can be satisfied 1 Solid and flat surface The appliance must be placed on a solid and flat surface or excessive vibration and noise may be produced when the appliance
6. heck the test bottle to see if the temperature complies with desired value 6 Switch on the light and check the lighting condition 7 Do not load excessive material in the appliance which has been thoroughly tested and assured as operational Procedures for temperature sensor calibration The temperature sensor is connected to the test bottle The following are instructions for calibration clearance of the sensor 1 Remove the fixing panel of the sensor 2 Remove the sensor from the test bottle 3 Fully stir the solution of broken ice cubes and cold water in a vacuum flask 4 Place the sensor in the solution 5 Continue to stir the icy solution until the temperature of the solution is 0 C measured by a precise thermometer Test the temperature displayed on the sensor to be calibrated 6 Wait until displayed temperature stabilizes If the displayed temperature is not 0 C calibrate using the following procedures If displayed temperature is 0 C continue the procedure from A article 7 a Hold the Calibration Confirmation button pressed for about 5 seconds until C1 appears b Press the Sensor Option button for selection of required sensor code upper sensor is C1 lower sensor is C2 and control sensor C3 c Press Calibration Confirmation button 0 C is displayed for 5 seconds d Selected mode will be inactivated 90 seconds after latest press of the button 7 Take out the sensor from the icy solution and dry the
7. in operation 2 Away from heat sources The appliance should be placed in an area away from heat sources including radiators gas or coal stoves or the cooling efficiency of the appliance may be reduced 3 Away from sunlight The appliance may not operate properly if it is under direct sunlight Prolong exposure to sunlight may shorten the service life of the appliance 4 Dry The appliance should not be placed in a damp area CAUTION Circuit breaker If the appliance has to be used in a damp area a circuit breaker must be installed and the appliance must be grounded The circuit breaker is installed in the power circuit Contact authorized retailer or technician of the manufacturer for further information 5 Clean and tidy The appliance should be operated in an area free from chemicals material which might generate gas or excessive dusts 6 Well ventilated The appliance should be placed in a well ventilated area Poor ventilation may reduce the cooling efficiency of the appliance 7 Grounding Appliance must be grounded to prevent electrical hazards WARNING A N Plug with a grounding pin should be used for the appliance to prevent electrical shocks 9 Do not ground the appliance to water pipes as frequently PVC pipes are used for water supply system SO Do not ground the appliance to gas pipes as this may result in dangers YQ Do not ground the appliance to telephone lines or lightni
8. lectric shorts or hazards Unauthorized disassembly repair or restructure is not allowed as fire or injury may result Unplug the appliance if the appliance develops a fault to avoid electric shocks or fires Do not install the appliance in an area where toxic or radioactive materials are stored Special personnel should be authorized for disposal of discarded appliances to avoid accidental entrapment in the appliance Cables with a section area of 0 75mm should be used for extension of power cable Do not step on electrical cables when moving or installing the appliance Damaged or worn electrical cables must be replaced with the material provided by an authorized after sales agent Maintenance and repair A N WARNING Unplug the appliance before commencing repair maintenance and or inspection Attention should be paid by technicians carrying out maintenance of the appliance to avoid inhalation of harmful dusts and powders in the air Cleaning 1 The appliance should be cleaned once a month 2 Wipe clean the external surfaces and internal accessories of the appliance Mild detergent can be used if necessary 3 Dry the appliance both inside and outside with soft cloth after cleaning with water 4 Do not use excessive water for cleaning the appliance to avoid damage to the insulation materials 5 Do not use any lubrication oils inside the appliance since the compressor and other mechanical accessories are
9. ng rods which may transmit strong electrical current in stormy days 8 Ensure that no article can fall on the top of the appliance CAUTION Do not place the appliance in an area where foreign articles may drop onto the appliance as electrical components are installed on the top of the appliance Installation Before use Installation 1 Unpacking Remove all the packing materials and open the door of the appliance to ventilate Mild detergent solution can be used to clean the appliance external surfaces 2 Leveling Turn the adjustable bolt anticlockwise to level the appliance 3 Fixing the shelf fence Take out the shelf fence and fix it on the rear wall of the compartment with M5 screws 4 Preparation for the temperature sensor test bottle Before using your appliance ensure that the test bottle in the drawer is filled with solution to the scale 200 If not follow the instruction listed hereunder to fill the test bottle including upper and lower test bottle with 10 glycerin or other solution such as glycol 1 2 3 4 5 6 Remove the upper and bottom drawers and then sensor fixing panel Dismount the sensor from the test bottle Remove the two screws for dismounting the test bottle Fill the test bottle with 10 glycerin or other solution such as glycol to the scale 200 Replace the capped test bottle in its original position Set the sensor on the test bottle and replace the
10. ning Door warning indicator on and buzzer signal 1 minute later Lamp Lamp 15W 1 Accessories Key 1 set Operation manual 1 Plastic bag 1 88kg 99kg UN7 0 8 8V7 0AH Net weight Rechargeable battery Properties Model HYC 260 HYC 360 340W 430W Input power Period before power interruption warning 72 hours with battery fully charged Note Technical information may vary from the appliance that you have just purchased due to technical improvements Safety precautions Please read this Operation Manual carefully before using the appliance Instructions in this manual must be strictly followed This manual contains significant information related to safety operation of your appliance Follow the instructions in this operation manual to safely operate your appliance and to avoid potential hazards In this manual and on labels attached to this product the words WARNING and CAUTION mean the following N WARNING A potentially hazardous situation which if not avoided could result in serious injury or death Z CAUTION A potentially hazardous situation which if not avoided may result in minor or moderate injury or damage to the equipment Label indications for example N indicates Careful QO indicates Forbidden 1 indicates regulations This operation manual should remain attached to this appliance Safety precautions N WARNING S Do not use your appliance outdoors to o
11. s 2 8 C The display returns to display inside sensor temperature or average temperature before setting is made not flashing
12. sensor 8 Connect the sensor with the test bottle by reversing procedures 1 and 2 Contact qualified technician for space adjustment Remote warning terminals The remote warning terminal 30VDC volume and 2A dry contact is on the rear panel of the appliance The remote warning terminal is coordinated with an audible alarm The warning can be stopped by depressing the buzzer If the power supply source is disconnected the remote warning operation cannot be stopped by depressing the buzzer Remote warning Normal On Abnormal Off Door handle Shelf Casters 10 2 1 Control panel The operation mode and temperature are displayed on the control panel Pressing the button on the control panel will display the current temperature and warning data 2 Light switch Control of the lights inside the appliance 3 Battery switch Rechargeable battery switch for control of power interruption Position 1 for On and Position 0 for Off Caution The switch must be set to position On while the appliance is in operation Caution Set the battery switch to position Off if the appliance is not used for a long period 4 Door handle Elegant design and unique finish 5 Casters Casters designed for free movement of the appliance 6 Shelf 7 Inner light 15W Operation During power interruption fully charged batteries can keep the warning function operational for 72 hours If power interruption occurs a while after th
13. sensor fixing panel Operation Instructions 1 Temperature display Preset temperature of the appliance is 52 C Preset warning point of high temperature is 8 C and of low temperature is 2 C Table 1 Temperature display Light on OLight off 1 Plug for power supply Test bottle average temperature Average O ee a Up OLow temperature 3 Press temperature Lower test bottle temperature Lower test bottle display button OUp Low temperature Press temperature Average temperature of test Average display button bottle temperature Up Low Caution Displayed temperature is detected by test bottles for upper and lower sections of the appliance and does not always remain at 5 C The information displayed by the snesor indicates the average temperature Operation Instructions Temperature adjusting Press and hold both SENSOR SELECT button and CALIB CANCEL button for more than 3s until original setting starts flashing to indicate that it enters temperature setting mode With each press of CALIB CANCEL button temperature setting increases 0 1 Cuntil reaching upper limit which is defaulted as 8 C If press again it returns to lower limit which is defaulted as 2 C It repeats the above cycle When it reaches your desired temperature if you don t press the button within 5s the temperature setting will be saved and it automatically quits the temperature setting mode the temperature setting range programmed at factory i