Contents
1. NO TIMER Spray Control Display On Off A Lamp Spray Control Button 1 Power Button Before turning on make sure there is water in the unit Press the Power Button Warm or Cool Mist Button Press to select warm or cool mist Water temperature is maintained at room temperature for cool setting and 80 degrees for warm WARM CooL When you press the Spray Control Button there are four options to choose from Press once for WEAK Press twice for MIDDLE Press three times for STRONG Press four times for TURBO You will notice the lights get higher as the spray increases 4A Light Options Display Button Press the Display Button to turn the display lights ON or OFF 4B Light Options Night Light Feature Press the Lamp Button at the top of the unit to illuminate the night light feature 5 Water Refill Button When the Water Refill Button lights up it is time to refill the water tank DIRECTIONS FOR USE IN PROGRAMMABLE MODE The programmable mode allows you to set the timer to turn the humidifier both on off at a daily predetermined time This mode also allows the clock to be programmed Program Start FIRST TURN POWER BUTTON ON Nm Minute 1 Push Select Set Button until START is blinking on display 2 While START is blinking select the desired start time using Hour and Minute buttons AM or PM as indicated Select Cool
2. Warm preference 3 4 Select Spray Control preference 5 START indicator will remain lit once programmed Program Stop 1 Push Select Set Button until STOP is blinking on display 2 While STOP is blinking select the desired end time using Hour and Minute buttons AM or PM as indicated STOP indicator will remain lit once programmed 3 4 To cancel program press and hold select set button for two seconds START and STOP buttons will not be lit Clock Set 1 Clock must be set in order for timer to work properly 2 Push Select Set Button until TIME is blinking on display 3 Select actual time using Hour and Minute Buttons AM or PM as indicated MAINTENANCE TROUBLESHOOTING GUIDE e The temperature of the water remaining in the unit after use may be HIGH PROBLEM SOLUTION Do not submerse the unit in water or allow water to enter anywhere on the unit except the designated water tank Water vapor amp humidity are Power Plug Unplug and then try again not produced Power Failure When the power is returned try again Tank Installation Make sure the water tank is INSIDE THE BODY OF THE UNIT correctly attached Make sure spring on tank Pour excess water out of the unit but do not allow it to enter the hole where the water cap moves freely when pushed vapor comes out Wash out the unit with fresh water using the cleaning brush and a soft cloth as needed OUTER SURFACE OF THE UNIT Air blows but water
3. because of the added humidity in the room e Fully dry the inside and outside of the unit before storing it Use distilled water if this becomes a nuisance e DO NOT leave water in the unit e Store in a cool dry place E 8 E 9
4. vapor is Excessive Water Remove a certain amount of water Wipe the surface of the unit with a soft damp cloth if needed not produced from the tank The desired humidity is lower than the current tem WATER TANK perature Increase the desired humidity If water spots remain in the water tank wipe the inside with a soft cloth Detergent residue in the tank Wash the tank out and DO NOT use soap or detergents try again AIR FILTER i The surface of the ultrasonic metal disk may be dirty Gently wipe away debris from the filter with a soft cloth Humidity level is low Wipe it off with a dry soft cloth Clean with diluted This filter does NOT need to be replaced vinegar ULTRASONIC DISK The water in the unit is too cold Replace with cool i s but not cold water Remove spray spout Fig 1 and use the enclosed cleaning brush to regularly remove build up and deposits from this area Fig 2 Diluted vinegar will help to prevent this build up Warm humidity is not produced It may take 10 15 minutes before warm humidity is created The mist may not feel warm to the touch Check to see if base of unit feels warm to the touch If so then warm mist is being produced Fig 2 The humidity has a bad smell Poor maintenance or dirty water Clean the product thoroughly and fill it with fresh water White dust is forming on Hard water will deposit a certain amount of STO RAG E nearby furniture dust Dust in the air settles
5. guardian technologies USE amp CARE INSTRUCTIONS Ultrasonic Digital Humidifier Remanufactured Model No R3010 English E 1 30 Day Limited Warranty Spanish S 1 www guardiantechnologies com 1 866 603 5900 Date Purchased month year READ AND SAVE THESE INSTRUCTIONS PRODUCT SPECIFICATIONS AND PARTS SPECIFICATIONS Model Number R3010 Humidifying Mode Combination Power Supply AC120V 60Hz Power Consumption 140W 40W at cool humidification Humidity Capacity About 350 cc hr at highest setting and warm humidification Tank Capacity 1 4 gallons Successive Humidity Hours Up to approximately 72 hours depending on environmental conditions Dimensions Width 14 5 inches Height 12 inches Depth 9 inches Weight 8 8 pounds not including packaging PARTS Tank Lid To access cleaning brush pull up on lid Power Plug Night Lamp READ AND SAVE THESE INSTRUCTIONS CONTROL PANEL BUTTON FUNCTIONS Night Light Lamp Provides a soft ring of blue light with ON OFF switch Night Light Lamp Select Set Change between programming mode and normal mode Hour Select the hour for timer start off Select Set or clock actual time Display Minute On Off Select the minute for timer start Hour off or clock actual time Spray Minute Control Power Turns humidifier on off for normal usage and programming mode Power Warm or Cool Mist Selection Warm or Cool Mist Selection Select hum
6. idifying temperature based on need Warm humidity will use more power but will humidify your room quicker Spray Control Adjusts spray between low medium high and turbo Display On Off Turns off display lights Water Shortage Indicator When the unit is low on water the Refill LED on the front panel will light up and the unit will shut off Simply add more water to continue use ADDITIONAL FEATURES Silver Clean Technology Small silver particles have been added to the water tank to help fight the growth of mold and mildew on the surface of the water tank Silent Operation Uses ultrasonic technology for quiet operation while you sleep E 3 READ AND SAVE THESE INSTRUCTIONS WARNINGS This product should be used only in accordance with the specifications outlined in this manual Usage other than what has been specified here may result in serious injury Disassembly repair or remodeling by an unauthorized person may result in serious harm Do not use if plug is damaged or loose Keep this product out of the reach of children and away from pets Be careful not to put water in the humidity spout Before filling or cleaning the unit make sure it is unplugged Once the humidifier has been turned on do not move it Do not move when in operation Do not remove the water tank from the unit while it is on Do not handle the adapter plug with wet hands Do not excessively bend twist or pull the power cord Avoid placing this pr
7. oduct where the humidity is pointed directly at an electrical object Do not directly inhale the humidity Do not place this product on a sloped or unstable surface When not in use unplug the unit Do not fill the water tank with hot or boiling water Do not use this product in direct sunlight or near a gas stove or heater Do not use if the water tank becomes cracked or damaged Do not keep this product running for an extended period of time Do not clean the unit or water tank with detergents or chemicals of any kind Do not use this product near any other electronic device Do not cover the humidity opening at any time during use Do not use this product near a sink Do not drink water from the water tank Do not place this product on an absorbent surface Do not pour anything but water into the water tank Failure to comply with the warnings listed above may result in electric shock or serious injury E 4 DIRECTIONS FOR USE Make sure the unit is unplugged 1 Separate the tank from the body of the unit 3 Pour cool clean water directly into the tank Do not pour anything but water into the water tank 5 Attach the tank to the body of the unit ay I D 6 2 Open the tank lid turning it to the left 4 Close the tank lid turning it to the right E 5 DIRECTIONS FOR USE IN NORMAL MODE
Download Pdf Manuals
Related Search
Related Contents
PFD-P250•500VM-E NOTA - Tam AG KVM switch - Hall Research Samsung PS-50P4H1 Benutzerhandbuch Installation Manual Cables Direct 1.2m SCSI-3 HP68 Automatic Control Panel, Type EP103 BakkerElkhuizen BNELMD mice AirCare RepairNet User Guide Version 5.0 ESTRANGULADOR HIDRÁULICO 30 TM Copyright © All rights reserved.