Home
GTO FM121 User's Manual
Contents
1. Attach RED solar panel wire to the SOLAR terminal marked Attach BLACK solar panel wire to the SOLAR terminal marked Solar Panel Wires RED BLK o 5 e m z fe oO o 2o ao wo or gt L N SW2000 2002XL SW3000 3200XL SW1000 SW2000 SW4000 4200XL Control Boards FM700 FM702 SL1000 SL2000 Control Boards Solar Panel Wires Solar Panel Wires RED RED BLK BLK Solar Zones and Gate Activity Use the table and map to determine the se Yee E to expect in your area using 5 to 30 4 8 B Watts of charging power Figures are shown for winter minimum sunlight and do not account for the use of any accessory items Single gate installation with 5 Watts of charging power Single gate installation with 10 Watts of charging power Single gate installation with 20 Watts of charging power Single gate installation with 30 Watts of charging power Dual gate installation with 10 Watts of charging power Dual gate installation with 20 Watts of charging power An operational cycle is one full Dual gate installation with 30 Watts of charging power opening and closing of the gate Number of openings per day will All dual gate installations require a minimum of 10 Watts of solar charging power depend on the length weight hard ware and environmental conditions
2. Accessories will draw additional power from the battery the more accessories you connect the more power your system will require We recommend that you purchase an extra 12V 7 amp hour battery RB500 for the FM500 502 SW2500 2502 SW3000XL 3200XL SW4000XL 4200XL Multiple Panel Installations NOTE All connections should Solar Panels connect in PARALLEL be weather proofed using weather proof splice kits avilable at hard ware and electrical supply stores attach BLACK to negative solar terminal on control board attach RED to positive solar terminal on control board Other Mighty Mule and GTO PRO Access Controls and Accessories Push Button Control FM132 k Unlit doorbell button for remote entry or exit control Wires directly to the control board and uses 16 gauge multi stranded dual conductor low voltage wire sold separately Pin Lock FM133 The Pin Lock substitutes for the clevis pin at the front end of the Mighty Mule gate operators Helps prevent theft of the operator from the gate while allowing quick release of the operator Key Chain Two Button Transmitter FM134 The Key Chain Mini Transmitter is a miniature version of the Mighty Mule entry trans mitter and has the same adjustable code settings 12 Volt battery included Single Button Transmitter FM135 The Mighty Mule entry transmitter with adjustable code settings is standard equipment with all Mighty Mule systems
3. driveway or where space prevents gate s from opening inward pulled open Order two PTO brackets for conversion of a dual swing gate installation D Column Mount Lock Receiver 433IH IT For mounting the Automatic Gate Lock on brick columns walls or for other applications with limited space between gate and post Replacement Transformer RB570 Standard 18 volt 2200 mA AC transformer for maintaining the battery included with the Mighty Mule gate operator This is the only transformer approved for use with all UL325 Mighty Mule gate operator systems Garage Door Receiver RB709U The Garage Door Receiver allows you to use the same Mighty Mule entry transmitter see Dual Trans mitter to operate your gate operator and your garage door operator Compatible with most garage door operators If you have a question about any special order item just call 1 800 543 GATE FING GATES THAT OPEN 3121 Hartsfield Road Tallahassee Florida USA 32303 Telephone GTO Sales 1 800 543 GATE 4283 or 850 575 0176 Fax 850 575 8912 or GTO Technical Service 1 800 543 1236 or 850 575 4144 Fax 850 575 8950 www gtoinc com The contents of all material available on this installation manual are copyrighted by GTO Inc GTO unless otherwise indicated All rights are reserved by GTO and content may not be reproduced downloaded disseminated published or transferred in any form or by any means except with the pri
4. Comes with a keyed manual release Recom mended for gates over 8 ft long Ideal for animal enclosures or high wind areas B Wireless Entry Intercom Keypad FM136 E Allows owner to screen guest at the gate before allowing access to the property Keypad r Bl also allows owner to give up to 25 programmable entry codes to family friends or approved lee delivery personnel Codes can be permanent of temporary Can be wireless up to 500 feet or hard wired up to 1000 feet Additional base stations available F3101MBC Other Mighty Mule and GTO PRO Access Controls and Accessories Replacement Battery FM150 lt a Standard 12 volt 7 0 amp hour maintenance free battery for the Mighty Mule FM500 amp FM502 gate operator systems This is the only battery approved for use with the Mighty Mule FM500 amp FM502 gate operator systems Life expectancy is 3 5 years Low Voltage Wire RB509 The 16 gauge multi stranded dual conductor Low Voltage Wire is for connecting the AC powered transformer or the Solar Panel to the control board Also used for the connection of accessories such as locks keypads push buttons and other wired control devices This specially designed wire is UV treated PVC coated and ready for direct burial Available in 50 100 250 500 and 1000 foot rolls 11 Push to Open Bracket FM148 gt gt Required when Mighty Mule 500 502 gate operator s must push the gate open such as on a sloping
5. 12 Volt battery included Digital Keypad FM137 The specially designed digital keypad can be easily installed as a wireless or wired keypad It can be programmed to use up to 25 different personal identification number PIN codes Each code is face programmable with additional security features built in Wired installa tions require 16 gauge low voltage multi stranded dual conductor direct burial wire sold separately Requires 3 AA batteries not included Mounting Post FM100 In Ground This black powder coated pedestal is designed to provide convenient access to your keypad wireless intercom or other access control device from your vehicle With its break down design it is easy to install and works well in most standard applications Surface Mount Flanges F102 and Extensions F103 for added height are available Gate Opening Sensor FM138 The Mighty Mule Gate Opening Sensor is designed for residential and agricultural applications and is compatible with all Mighty Mule automatic gate operator models The wand is an electromag netic sensor which offers hands free operation of the Mighty Mule Gate Operators with a 12 ft radius of detection of vehicles in motion Automatic Gate Lock Pull to Open FM143 A MUST for added security Solenoid driven with a steel housing Unlocks and locks automatically as gates open and close Used with Mighty Mule DC swing gate operating systems for maximum stability and security
6. MUME E Z GATE OPENER Solar Powered Battery Charger Installation Manual Compatible with all Mighty Mule and GTO PRO DC Powered Slide and Swing Gate Operators except for the Mighty Mule 250 FM250 All dual gate installations require a minimum of 10 Watts of solar charging power Parts Included Solar Panel Lag Screws 4 Pipe Clamp 4 Curved Pipe 1 4 Nuts 4 1 4 x 1 2 Bolt 4 G Wire Nuts H Compass Tools Required e Slotted flat blade Screwdriver e 7 16 open end wrench For more information on Mighty Mule s full line of automatic gate openers and access controls visit our website at www mightymule com RB905 Rev 11 5 07 2007 GTO Inc Printed in China for GTO Inc Solar Panel Installation Step 1 Slide the 4 bolts F through the bottom of each channel so threaded part of each bolt comes through top of frame position the pipe D between the bolts and place two clamps C over the curved pipe onto the bolts The clamp at the top of the solar panel should fit over the pin on the curved pipe Secure with the 1 4 nuts E Step 2 Determine the site for installation of the solar panel It is important to install the solar panel facing the path of the sun where full sun will strike its face throughout the day The solar panel cannot be shaded out or obstructed by trees bushes building
7. ariable during the day depending on the intensity of the sun and the angle of the rays striking the panel The output may vary from a few millivolts to as much as 22 volts To check the output simply disconnect the solar panel leads from the control board and connect them directly to a dc voltmeter In bright sunlight the panel output should read at least 18 volts dc at approximately 300mA Step 3 All Mighty Mule and GTO PRO DC powered gate operators have a POWER IN terminal on their control boards marked SOLAR for connecting the solar panel wires Below are various types of terminals on GTO PRO and Mighty Mule control boards if your control board doesn t have this terminal please call the GTO s Technical Service Department at 800 543 1236 or 850 575 4144 for assistance Feed the free end of the solar panel wires into the control box and attach them to the SOLAR terminals on the POWER IN terminal block on the control board The RED solar panel wire goes to the POSITIVE Solar ter minal and the BLACK solar panel wire goes to the NEGATIVE Solar terminal See diagram below IMPORTANT Improper installation of these wires will damage to the opener s control board aa s Nc RY COM NO 18 VAC SOLAR RELAY OUT 18VAC SOLAR DYSOSBAYSD Solar Panel Wires Solar Panel Wires RED RED BLK BLK SW3000 3200 SW4000 4200 Control Boards FM500 FM502 SW2500 Control Boards
8. or written permission of GTO Any reprinting of GTO publications is by permission only Copyright infringement is a violation of federal law Mighty Mule E Z Gate GTO are registered trademarks of GTO Inc America s DIY Automatic Gate Openers is a trademark of GTO Inc and are the exclusive property of GTO Inc GTO All rights are reserved by GTO and these marks may not be used in any for without the prior written permission of GTO
9. s etc for any part of the day The curved pipe D maintains the proper angle to the sun Secure the solar panel assembly to a wooden post or fence using two pipe clamps C and 2 lag screws B as shown in the illustration If your fence post is metal you will need alternative hardware not pro vided i e U clamps or metal screws IMPORTANT the solar panel must be positioned facing the path of the sun due south and in an open area away from shade It should receive at least 8 hours of direct sunlight for a full charge HINT If the solar panel must be placed more than 10 ft from the control box but less than 250 feet away use multi stranded 16 gauge AWG direct burial low voltage wire RB509 see Accessory Catalog Never use telephone wire or solid core wire IMPORTANT To provide secure and moisture resistant splices for solar panels use a direct burial splice kit for underground splices and an above ground splice kit for above ground splices These splice kits can be found at hardware and electrical supply stores HINTS for Obtaining Maximum Output from Your Solar Panel 1 Place the panel facing due south in the path of the sun where full sun will strike its face throughout the day minimum amp hours 2 Mount the panel using the curved pipe provided to maintain the proper angle to the sun 3 For optimal efficiency wipe the face of the panel frequently with a soft damp cloth The output of the Solar Panel is v
Download Pdf Manuals
Related Search
Related Contents
instructions for Istruzioni per l`uso - Camille Bauer Metrawatt AG Manuale di istruzioni MX5 Introduzione La MX5 è ==!"§ Manuel d`installation RMP60 – palpeur radio Manuale di installazione e manutenzione per automazioni per Acme Made KS02 zusatzinformation zur bedienungsanleitung Tain Electronics Soil Moisture Logger User Guide Copyright © All rights reserved.