Home

GE Wayside Signals Data Sheet

image

Contents

1. UC Lighting Solutions LED Colorlights Wayside 8 inch 200 mm 10V DC 96 Series Outstanding Reliability Improved contact resistance immunity e Compatible with most controllers with light out detection circuits e Self contained design provides protection against moisture and dust e Backed by a 48 month limited warranty Over 210 000 wayside signals sold worldwide Excellent Appearance amp Visibility e Robust LED system design enables high luminous intensity over long product life e Efficient optical system delivers uniform color across both wide and narrow beam signals Sun Phantom reducing features have been incorporated in our design RM4 Way side e Easy to install and align Meets Rigorous Certification amp Testing Standards e Meets selected AREMA recommended practices as detailed in the Design Compliance Table All lamps undergo comprehensive testing in the manufacturing plant e Meets key failure rate criteria as per EN 50129 Detailed rating table with duration and operating conditions available upon request imagination at work Mid Range Visibility to 2000 ft 600 Typical Voltage Current Curves iecsuredatz0 Typical Light Distribution Wayside Signal Green 4 5 288 966 4 5 288 966 Luminous Aniar i Distribution a Green Aspect 1 ae 1 2 4 DRAW
2. w 88 7 RM4 WSFB 75B 96G 15W 90 Notes 1 This is minimum stabilized value at T 25 C Distributed by 2 For VI Curves and Isocandella graphics please refer to Pages 3 and 4 gt Signal performance when exposed to external light ex sun head lamp is dependant on each application field testing is recommended GE Lighting Solutions 1 888 MY GE LED www gelightingsolutions com 1 888 69 43 533 for North America or 1 216 266 2419 GE Lighting Solutions LLC is a subsidiary of the General Electric Company The GE brand and logo are trademarks of the General Electric Company 2013 GE Lighting Solutions LLC Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions RAIL268 RO70213
3. RM4 GSFB 28B 96GK ae n 21 IITTI 0 Vertical Angle 71 Light Output relative ee eS Horizontal Angle RM4 YCFB 43B 96GK Luminous Intensity Angular Distribution 1 Yellow Aspect 1 2 S RM4 YCFB 43B 96GK 5 a _ 5 iE Eos at 20 2 e A gt Voltage in WOC increasing amp decreasing RM4 RSFB 43B 96GK Luminous intensity Angular Distribution Wayside Signal Bin Red 2 4 22 2 Red Aspect he jd RSFB 43B 41 RM4 RSFB 43B 96GK 21 HEE 5 3 5 Eos F EA 2 a E E E E E E E E a 2 e eE Voltage in VOC incroasing amp decreasing neil RM4 WSFB 28B 96GK Luminous Intensity Angular Distribution 70 ATTS Le White Aspect a ALN 1 5 RM4 WSFB 288 96GK s CA See ea 220200 Mit See Definitions gt e Peak Maximum Luminous Intensity Vertical Angle Light Gutput 9 relati
4. tage in increasing amp decreasing Horizontal Angle LED Colorlights Wayside 8 inch 200 mm 10V DC e 96 Series Mechanical Outline Dimensions in inches mm indicates metric equivalent _ 2 4 15 61 8 2 38 208 2 2 O 56 IT 6 196 152 Design Compliance Operating Specifications Characteristic Compliance Parameter Rating Impact Resistance of Front Shell IR3 Operating Temperature Range 40 to 70 C 40 to 158 F Mechanical Vibration amp Shock AREMA 11 5 1 D 4 D 5 Class B Nominal Operating Voltage 10V DC Water Dust Ingress Protection Operating Voltage Range 8 16V DC int Rail ies yp g Voltage Turn Off 3 5V DC Dielectric Strength AREMA 11 5 1 D 7 Class B Turn On Turn Off Time 27516 Electrical Surge Protection EN61000 4 5 Class 3 AREMA 11 3 3 Typical Clamping Voltage AREMA 11 3 3 42V Electromagnetic Compatibility EMC FCC Part 15 Subpart B Maximum Allowable Surge Voltage and Energy Handling Capability AREMA 11 3 3 E 65V DC amp 15J for 2ms Product Information Model Number Aspect Nominal Number Color Watts of LEDs Short and Mid Range Visibility to 2000 ft 600 m RM4 GSFB 28B 96GK 90 RM4 YCFB 43B 96GK 18W 132 RM4 RSFB 43B 96GK Red 18W 132 RM4 WSFB 28B 96GK 15W 90 Long Range Visibility to 5000 ft 1500 m RM4 GSFB 75B 96G 90 RM4 YCFB 85B 96G 88 RM4 RCFB 75B 96G Rd
5. ve Vottage in VDC increasing amp decreasing Horizontal Angle Beam Angle 50 of Peak Intensity e Field Angle 10 of Peak Intensity Long Range Visibility to 5000 ft 1500 m Typical Voltage Current Curves iecsuredatzo Typical Light Distribution RM4 GSFB 758 96G Luminous Intensity Angular Distribution Green Aspect RM4 GSFB 75B 96G Vertical Angle 21 Veltage in VOC increasing amp decreasing Light Ouiput 5 relative Horizontal Angle RM4 YCFB 85B 96G Luminous Intensity Angular Distribution Wayside Signal 8 Yellow 458 966 2 Hee eee Yellow Aspect a 3 j ance RM4 YCFB 85B 96G 2 tH 882 992 864 Voltage in VOC increasing amp decreasing Horizontal Angle RM4 RCFB 75B 96G Luminous Intensity Angular Distribution Wayside Signal 8 Red 5 960 s Red Aspect 314 RM4 RCFB 75B 96G E J 5 Horizontal Angle RM4 WSFB 758 96G Luminous Intensity Angular Distribution White Aspect RM4 WSFB 75B 966 Vertical Angle 1 5 2 Vol