1. Front And Back Sight Into Position Step 4 Sighting Device lowered into position Reflector Sighting Device raised into position After positioning luminaire tighten all mounting hardware STEP 5 Connect power cable to suitable supply in accordance with all applicable codes INSTALLATION CLEANING DO NOT CLEAN INTERNAL OPTICAL SYSTEM The UltramSport floodlight has been specially cleaned at the factory Field cleaning of the internal optical system during installation is not recommended EXTERNAL CLEANING Initial cleaning of the outside of the glass lens may be required to ensure optimum optical efficiency Clean front glass with a mild soap and water solution rinse clean and wipe dry CAUTION Risk of burn Allow lamp fixture to cool before handling LAMP REPLACEMENT A Insert the lamp terminal into the socket terminal a at both ends of the lamp and tighten screws CLEANING INSTRUCTIONS AND CAUTIONS Caution do not touch quartz tube with bare hands If lamp is handled finger prints grease or oils should be removed from the lamp with isopropyl alcohol This will remove materials which cause whitish spotting and premature lamp failure Dry lamp carefully with cotton or clean cloth PERIODIC CLEANING WHEN RELAMPING INTERNAL Should the internal reflector system require cleaning use only non abrasive neutral pH 6 8 cleaner containing no chlo
2. GE Lighting Solutions GEH 5746E INSTRUCTIONS Ultra Sport Luminaire with Hot Restart Option READ THOROUGHLY BEFORE INSTALLING A WARNING Risk of electric shock e Turn power off before servicing see instructions NOTE Make all electrical connections in accor dance with the National Electrical Code and any applicable local code requirements A WARNING Risk of fire e Keep combustible materials away from lens see instructions e Use lamps specified on nameplate NOTE Do not place combustible materials within 7 feet 2 meters of the front of the reflector lens This luminaire is designed for use in outdoor applica tions and must adhere to 25 C Max ambient tempera ture limitation unless otherwise stated on nameplate Install and maintain it according to the following recom mendations NOTE Verify that supply voltage is correct by comparing it to nameplate SERVICE CONSIDERATIONS 2 Sealed Reflector Assembly Luminaire is equipped with oe a safety circuit to prevent lamp A operation if the lens is broken If any component such as reflector lens or casing is damaged the complete assembly must be replaced Relamping Door Luminaire is shipped with lamp in place Door may be opened for relamping Door must be sealed during opera tion Ballast Compartment DO NOT REMOVE THIS COVER There are no field serviceable components under this cover Balla
3. rinated or aromatic hydrocarbons Rinse clean and wipe dry EXTERNAL Clean front glass with a mild soap and water solution rinse clean and wipe dry B Snap the lamp ends into the lamp retaining clips b C Close and rebolt the relamping door Tighten bolts to 50 in lbs torque REMOTE BALLAST MOUNTING See below illustration for bolt spacing and bracket minimum spacing GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 S9 3 01
4. sting components must be maintained by factory trained service techni cians only Unit will fall if not installed properly e Follow installation instructions STEP 1 INSTALLATION PROCEDURES Verify that the drain holes are in the proper locations for the intended aiming direction If not contact the factory _ a r a Drain holes for fixtures aimed above horizontal Drain holes for fixtures aimed below horizontal STEP 2 LUMINAIRE MOUNTING Reference Mark Angle Indicator Adjustment Bolt Crossarm Adapter and Hardware not supplied These instructions do not purport to cover all details or variations in equipment nor to pr or maintenance Should further information be desired or should particular problems ari referred to GE Lighting Solutions ovide for every possible contingency to be met in connection with installation operation se which are not covered sufficiently for the purchaser s purposes the matter should be Step 3 LUMINAIRE AIMING Two sighting systems are provided for your convenience Use the sight system which is most easily accessed Optical Sight A Rotate sight into vertical position B Align the reference mark of top of reflector flange with notch in sight for proper aiming Base Sight A Rotate front and back sight into vertical position B Align the two sighting holes for proper aiming Proper Alignment Position
Download Pdf Manuals
Related Search
Related Contents
Manual de instalação, operação e manutenção KERN KMB/KMS/KMT-TM オンサイト保守サービスについて Copyright © All rights reserved.
Failed to retrieve file