Home

GE P54S Installation Guide

image

Contents

1. reconnectable units move only the lead with the insulated connector IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire LAMPS Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp The lamp should be securely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure application of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket MAINTENANCE CAUTION Risk of burn e Allow lamp fixture to cool before handling A WARNING Risk of burn e Do not touch operating luminaire The ALZAKT finish on the reflector and the door glass may be cleaned with any suitable nonabrasive glass cleaning solution soap or detergent and rinsed with clean water GE Lighting Solutions x A LIRE TOTALEMENT AVANT D INSTALLER DANGER Risque d electrocution e Mettre hors tension avan
2. INSTRUCTIONS P 154 Powerflood Floodlight GE Lighting Solutions READ THOROUGHLY BEFORE INSTALLING A WARNING Risk of electric shock e Turn power off before servicing see instructions AVERTISSEMENT COUPER L ALIMENTATION AVANT L INSTALLATION OU L ENTRETIEN GENERAL This luminaire is designed for outdoor lighting service and should not be used in areas of limited ventilation or in high ambient temperature enclosures Best results will be obtained if installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed so that no part should have been damaged during transit Inspect to confirm INSTALLATION BOLT A A CAUTION WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Unit will fall if not installed properly e Follow installation instructions Verify that supply voltage is correct by comparing it to nameplate The floodlight is provided with a trunnion bracket which can be mounted directly on flat surfaces or building fronts If unit is designated as multivolt or multiwatt Mounting adaptors are available for installation on poles follow specific instruction cross arms pipes etc The trunnion bracket has a clearance hole for a 3 4 inch bolt used for attachment of such mounting The 1 2 inch holes on either side of the 3 4 inch hole permit ad
3. ampea faisceau large Powerflood P 154 PAT AN BOULON CABLAGE Effectuez tous les raccordements en conformit avec les normes nationales et les ventuels r glements locaux applicables V rifiez que la tension secteur disponible est la bonne en comparant avec l indication de tension sur la plaque d identification Si l appareil est con u pour tre multi tensions ou multi puissances suivez les instructions sp cifiques Un c ble trois conducteurs N 14 avec isolation thermique 90 C minimum est recommand pour r aliser le raccordement d alimentation Ouvrez la lampe en desserrant deux vis B et en tirant la porte vers l avant Enlevez l cran d isolation du r flecteur pour exposer l acc s au c blage et au bornier Desserrez les vis de la plaque de pression ins rez le c ble dans le passe fil qui accepte un cable jusqu 14 mm ou 9 16 de diam tre et reserrez les vis Le passe fil et la plaque de pression constituent une tanch it contre les intemp ries et vitent les contraintes Pour maintenir cette tanch it il faut resserrer les vis de la plaque de pression chaque fois que l tanch it aura t perturb e Avant de refermer le luminaire assurez vous que l cran d isolation est bien attach au r flecteur Cesinstructions n ont pas pour destination de couvrir tous les d tails ou variantes de l quipement ni de r pondre toutes les ventualit s que vous pourri
4. ditional anchoring if required Tighten side trunnion bolts to 18 22 foot pounds Three conductor No 14 cable with 90 C minimum insulation is recommended for making electrical connections to the P 154 After opening door loosen the 2 screws holding the reflector Remove reflector thus expos ing the terminal board Loosen screw in pressure plate AIMING insert cable through grommet and retighten screw Notice Slightly loosen bolts A two on trunnion tilt that grommet fits cable of approximately 9 16 inch luminaire to desired position and retighten bolts diameter Grommet and pressure plate form a weather proof seal and strain relief To maintain this seal the screw in pressure plate must be retightened whenever the seal is disturbed After connections are made to the terminal board be sure insulating shield is properly placed These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions Connect ground lead to the green lead green ground screw on housing or terminal block provided Do not remove insulated connectors from wires not needed for required voltage connection When changing voltage on
5. ez rencontrer pendant l installation le fonctionnement ou l entretien Si vous souhaitez des informations compl mentaires ou sivous rencontrez un probl me particulier qui ne soit pas adress de votre point de vue d acheteur le sujet doit tre remont jusqu la soci t GE Lighting Solutions Reliez le fil de terre sur le fil vert sur la vis verte de terre du ch ssis ou la borne sp cifique de terre N enlevez pas les connecteurs isol s des fils non concern s par le raccordement de la tension En changeant la tension des unit s reconfigurables ne bougez que le fil avec la cosse isol e MONO TENSION Tous les ballasts sont pr c bl s et l utilisateur n a qu relier les fils d alimentation pour la tension pr vue MULTI TENSIONS 120 208 240 277 volts Reliez le fil de ballast avec sa terminaison isol e sur la borne de tension ad quate comme indiqu sur la plaque du ballast MULTI PUISSANCES Les ballasts multi puissances sont disponibles en diverses combinaisons de wattages Reportez vous aux instructions de c blage sur l tiquette l int rieur du luminaire LAMPES N utilisez que le type de lampe sp cifi sur la plaque d identification Observez les recommandations et restrictions du fabricant sur le fonctionnement de la lampe en particulier pour le type de ballast la position d utilisation etc Serrage de lampe culot goliath La lampe doit tre ins r e de fa on s re avec un couple de serra
6. ge NEMA EEI sp cifi 4 4 mkg 35 livre pouce ce qui est le mieux r alis en serrant fortement la main pour mettre un couple suffisant Le serrage doit compl tement appuyer et charger le contact central de la douille avec le culot de la lampe ENTRETIEN Le r flecteur en finition ALZAK et la porte vitr e peuvent tre nettoy s avec toute solution convenable pour vitres non abrasive base de savon ou de d tergent puis il faut les rincer l eau claire ATTENTION Risque de br lure e Laissez le bloc d ampoule refroidir avant d y toucher A ATTENTION Risque de brulure e Ne touchez pas le luminaire allum GE Lighting Solutions 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 5N 1 01
7. t d intervenir Suivez les instructions AVERTISSEMENT COUPER L ALIMENTATION AVANT L INSTALLATION OU L ENTRETIEN PRESENTATION Ces luminaires sont con us pour fournir un clairage l ext rieur et ne doivent pas tre utilis dans des zones ventilation limit e ou sous des temp ratures ambiantes lev es Les meilleurs r sultats sont obtenus avec une installation et un entretien conformes aux recommandations qui suivent DEBALLAGE Le luminaire a t emball correctement de fa on ce qu aucune de ses pi ces ne soit endommag e pendant son transport Veuillez proc der une v rification pour le confirmer INSTALLATION ATTENTION Risque de chute en cas de mauvais montage Suivez les La lampe faisceau large est livr e avec un support tourillon qui peut tre mont directement sur des surfaces planes ou des facades de b timents Des adaptateurs de montage sont disponibles pour une installation sur poteaux traverses tuyauteries etc Le support de tourillon a un orifice de d gagement pour un boulon de 3 4 de pouce pour la fixation avec de tels montages Les trous de 14 3 mm 0 562 de chaque c t permettent un ancrage suppl mentaire si c est n cessaire Serrez les boulons lat raux de tourillon 27 33 mKg 18 22 livre pied VISEE Desserrez l g rement les boulons A deux sur tourillon inclinez le luminaire en position voulue et resserrez GEH 5849 INSTRUCTIONS L