Home
GE P54H Installation Guide
Contents
1. OM GE Lighting Solutions GEH 5890 INSTRUCTIONS P 154 Powerflood Hazardous Location Floodlight READ THOROUGHLY BEFORE INSTALLING WARNING Risk of electric shock e Turn power off before servicing see instructions THE OPERATING TEMPERATURE T CODE LISTED FOR THIS LUMINAIRE IS BASED ON THE FOLLOWING BULB SIZES USE OF OTHER THAN THESE MAY RESULT IN A HIGHER OPERATING TEMPERATURE AND COULD RESULT INA HAZARDOUS CONDITION LAMP TYPE WATTAGE BULB SIZE HIGH PRESSURE SODIUM 70 100 150 ED 23 1 2 HIGH PRESSURE SODIUM 250 400 ED 18 METAL HALIDE MERCURY 175 250 ED28 METAL HALIDE MERCURY 400 ED28 GENERAL This luminaire is designed for outdoor lighting service and should not be used in areas of limited ventilation or in high ambient temperature enclosures Best results will be obtained if installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed so that no part should have been damaged during transit Inspect to confirm INSTALLATION CAUTION Unit will fall if not installed properly e Follow installation instructions The floodlight is provided with a trunnion bracket which can be mounted directly on flat surfaces or building fronts The trunnion bracket has a clearance hole for a 3 4 inch bolt used for attachment for such mountings The 1 2 inch holes on either side permit additional anchoring wher
2. 72 DANS UN ENVIRONNEMENT MARIN AVEC EAU SAL E Ce projecteur est fourni avec un support tourillon pouvant tre install directement sur une surface Le c blage doit tre r alis dans la bo te de c blage en bas de l appareild clairage plate ou sur la fa ade d un difice Le support tourillon poss de un trou d gag laissant passer un boulon 7 mi E a a de 3 4 po pour ce type d installation Les trous de 1 2 po sur chaque c t permettent de solidifier Lorsque le c blage est termin serrez le raccord d tanch it sur la bo te autour du c ble l installation lorsque cela est n cessaire Serrez les boulons de tourillon lat raux avec une force de 18 22 lb pi ENTRETIEN ORIENTATION Desserrez l g rement les boulons A deux sur le tourillon puis inclinez le liminaire l angle d sir A E N O N et resserrez les boulons Risques de br lure LAMPES are a e Laissez refroidir la lampe et l appareil Utilisez uniquement des lampes conformes aux exigences de la plaque signal tique Respectez les d clairage avant de les toucher recommandations du fabricant de la lampe ainsi que les restrictions s appliquant l utilisation de la ji lampe notamment sur le type de ballast la position de br lage etc suffisant pour enfoncer compl tement la lampe et charger le contact central de la douille Serrage de la lampe Lampe culot Goliath La
3. age Cette bo te poss de un raccord de conduite filet de 3 4 po NPT La m thode de c blage choisie doitrespecter la norme NFPA 70 conform ment au code lectrique national article 501 concernant les sites dangereux class s D BALLAGE de classe division 2 Saan i ne Sade gt A x Pourouvrirl appareil d clairage ouvrezlaporte desserrezlesdeuxvis retenant le r flecteur et enlevez Ce luminaire a t soigneusement emball pour qu aucune pi ce ne subisse de dommages durant le le r flecteur Assurez vous que la tension de l alimentation lectrique et la puissance de la lampe sont transport Proc dez une inspection pour vous en assurer correctes APPAREILS TENSION UNIQUE INSTALLATION Tous les ballasts tension unique sont pr alablement c bl s de sorte que l utilisateur n a plus qu connecter les conducteurs d alimentation APPAREILS TENSIONS MULTIPLES 120 208 240 277 volts A ATT E N T O N Branchez le conducteur du ballast cosse isol e sur la borne de tension appropri e conform ment aux indications sur la plaque signal tique des bornes du ballast APPAREILS PUISSANCES MULTIPLES Si cet appareil est mal install il Des ballasts puissances multiples sont disponibles avec diverses combinaisons de puissance tombera au sol Consultez les instructions de c blage sur l tiquette de c blage l int rieur du luminaire Suivez les insiflisiion daneiallation C BLAGE DE L APPAREIL UL 15
4. e required Tighten side trunnion bolts to 18 22 foot pounds AIMING Slightly loosen bolts A two on trunnion tilt luminaire to desired position and retighten bolts LAMPS Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp The lamp should be securely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure application of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate If unit is designated as multivolt or multiwatt follow specific instruction BOLT A Three conductor No 14 cable with 90 C minimum insulation is recommended for making electrical connections to the P 154 Wiring is accomplished through the wiring box provided on the fixture The box is provided with a size 3 4 in NPT threaded conduit opening Wiring methods must comply with NFPA 70 The National Electrical Code Article 501 for Class Division 2 Hazardous Classified Locations To get inside the unit open the door loosen the 2 screws holding t
5. he reflector and remove the reflector Verify the correct supply voltage and lamp wattage IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire WIRING UL 1572 OUTDOOR SALT WATER MARINE Wiring is accomplished through the wiring box on the bottom of the fixture When wiring is complete tighten weatherproof fitting on box around cable MAINTENANCE CAUTION Risk of burn e Allow lamp fixture to cool before handling WARNING Risk of burn e Do not touch operating luminaire The ALGLAS finish on the reflector and the door glass may be cleaned with any suitable nonabrasive glass cleaning solution soap or detergent and rinsed with clean water These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting S
6. lampe doit tre solidement ins r e avec une force de 35 Ib po normes NEMA EEI ce qui peut tre obtenu avec un serrage tr s ferme Le serrage doit tre AVE RTI SS E M E NT Risques de br lure CABLAGE e Ne jamais toucher ce luminaire lorsqu il fonctionne Toutes les connexions doivent tre conformes auxnormes lectriques nationales et la r glementation locale en vigueur La finition ALGLAS sur le r flecteur et la porte en verre peut tre nettoy e avec n importe quel savon Assurez vous que la tension lectrique est ad quate en v rifiant la plaque signal tique d tergent ou liquide lave vitre non abrasif puis rinc e l eau claire Ces instructions n ont pas pour destination de couvrir tous les d tails ou variantes de l quipement ni de r pondre toutes les ventualit s que vous pourriez rencontrer pendant l installation le fonctionnementou l entretien Si vous souhaitez des informations compl mentaires ou sivous rencontrez un probl me particulier qui ne soit pas adress de votre point de vue d acheteur le sujet doit tre remont jusqu la soci t GE Lighting Solutions GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting So
7. lutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 2Y 6 02
8. olutions G E GEH 5890 Lighting Solutions INSTRUCTIONS Projecteur P 154 Powerflood pour sites dangereux LIRE ATTENTIVEMENT AVANT D INSTALLER AVERTISSEMENT Risque d lectrocution e Couper l alimentation lectrique avant toute r paration Voir les instructions LA TEMPERATURE DE FONCTIONNEMENT T CODE FIGURANT SUR CE LUMINAIRE EST BAS E SUR L UTILISATION D AMPOULES DES GROSSEURS CI DESSOUS L UTILISATION D UNE AUTRE AMPOULE RISQUE DE PRODUIRE DES TEMPERA TURES DE FONCTIONNEMENT PLUS ELEVEES ET DANGEREUSES GROSSEURDE TYPE D AMPOULE PUISSANCE W L AMPOULE SODIUM HAUTE PRESSION 70 100 150 ED 23 1 2 SODIUM HAUTE PRESSION 250 400 ED 18 HALOG NURES MERCURE 175 250 ED28 HALOG NURES MERCURE 400 ED28 BOLT A GENERALITES Si cet appareil est tensions ou puissances mul tiples suivez les consignes applicables Ce luminaire a t con u pour une utilisation l ext rieur et ne doit pas tre utilis dans les endroits Un cable trifilaire n 14 avec une isolation thermique d au moins 90 C est recommand pour r aliser mal ventil s ni dans un endroit clos o la temp rature ambiante peut tre lev e Son efficacit sera les connexions lectriques du projecteurP 154 meilleure sil est install et entretenu conform ment aux recommandations ci dessous Le c blage doit tre ex cut dans la bo te de c blage fournie sur l appareil d clair