Home

GE JB988SK User's Manual

image

Contents

1. DO NOT remove the ground strap connection FOR POWER CORD INSTALLATION A Remove the 3 lower terminal screws from the terminal block B Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block Be certain that the center wire white neutral is connected to the center lower position of the terminal block C Tighten screws securely into the terminal block FOR CONDUIT INSTALLATION A Loosen the 3 lower terminal screws on the terminal block Strip wire to exposed tip about 5 8 long B Insert the center white neutral wire tip through the bottom center terminal block opening On certain models the wire will need to be inserted through the ground strap opening and then into the bottom center block opening Insert the two side bare wire tips into the lower left and the lower right terminal block openings C Tighten the screws until the wire is firmly secured 35 to 50 inch lbs Do not over tighten the screws NOTE ALUMINUM WIRING Aluminum building wire may be used but it must be rated for the correct amperage and voltage Power Cord Conduit Terminal block Terminal Ground plate PROCEED TO STEP 7 08 08 JR 6 4 WIRE INSTALLATION A WARNING The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block The power leads must be connected to the lower left and the lower right terminals o
2. Do not over tighten the screws NOTE ALUMINUM WIRING Aluminum building wire may be used but it must be rated for the correct amperage and voltage Before Power Cord and Conduit After Power Cord Ground strap Terminal fol PU Terminal gt f E Neutral Nes 5 i block p FSI I da A terminal Om i or h Y AT Ground plate grounding to Ground strap Neutral terminal O GROUND After Conduit Terminal Ground E plate block G grounding Tr v to range Wire gt tips Ground screw REPLACE THE WIRE COVER Replace wire cover on range back by sliding its left edge under the retaining tabs and replace the screws removed earlier Make sure that no wires are pinched between cover and range back SINGLE OVEN DOUBLE OVEN Back of range Back of range a e 5 screws to Screw to A remove remove Retaining wire cover terminal tabs f block cover Terminal block cover ANTI TIP DEVICE INSTALLATION To reduce the risk of tipping the range the range must be secured by a properly installed anti tip bracket See AWARNING installation instructions shipped with the bracket for complete details before attempting to install To check if the bracket is installed and engaged properly remove the storage drawer or kick panel and look underneath the range to see that the leveling leg is engaged in the bracket On models
3. 5 m s all del frente de los gabinetes Los gabinetes instalados por encima de la estufa no deben tener una profundidad mayor a los 13 3 REQUERIMIENTOS EL CTRICOS AADVERTENCIA Esta unidad debe contar con una adecuada conexi n a tierra A ADVERTENCIA Todas las construcciones nuevas casas rodantes veh culos recreativos e instalaciones donde los c digos locales no permiten una conexi n a tierra a trav s de un neutral requieren un cable para cocina de 4 conductores aprobado por UL A ADVERTENCIA Para prevenir un incendio o descarga el ctrica no utilice un cable de extensi n con este aparato A ADVERTENCIA Para prevenir una descarga el ctrica quite el fusible o abra el interruptor de circuitos antes de comenzar la instalaci n Recomendamos que un electricista calificado conecte el cableado el ctrico y su cocina Despu s de la instalaci n solicite al electricista que le indique c mo desconectar la energ a de la cocina Usted debe usar un sistema el ctrico de 60 hercios CA de fase nica de 120 280 voltios o 120 240 voltios Si tiene una conexi n con cableado de aluminio deben utilizarse conectores adecuadamente instalados para utilizar con cableado de aluminio Si el servicio el ctrico provisto no cumple con las especificaciones anteriores haga que un electricista con licencia instale un tomacorriente aprobado Vigente desde el 1 de enero de 1996 el C digo El ctrico Nacional requiere que las nuevas co
4. Los cables de energ a deben estar conectados a las terminales inferior izquierda e inferior derecha del bloque terminal NO QUITE la cinta de conexi n a tierra PARA INSTALACI N DE CABLE DE ENERG A A Quite los 3 tornillos inferiores del bloque terminal B Introduzca los 3 tornillos de terminal a trav s de cada anillo de terminal de cable de energ a y dentro de las terminales inferiores del bloque terminal Aseg rese de que el alambre central blanco neutral se encuentre conectado a la posici n central inferior del bloque terminal C Ajuste bien los tornillos al bloque terminal PARA INSTALACI N DE CONDUCTO PORTACABLES A Afloje los 3 tornillos inferiores del bloque terminal Pele el cable de la punta expuesta con una longitud de 5 8 B Introduzca la punta del cable central blanco neutral a trav s de la abertura del bloque terminal central inferior En algunos modelos el cable tendr que introducirse a trav s de la abertura de la cinta de conexi n a tierra y luego a trav s de la abertura del bloque central inferior Introduzca las dos puntas de cable pelado dentro de las aberturas de bloque terminal izquierda inferior y derecha inferior C Ajuste los tornillos hasta que el cable quede bien firme 35 a 50 pulg lbs No ajuste los tornillos de m s NOTA CABLEADO DE ALUMINIO Puede utilizarse cable de construcci n de aluminio pero debe clasificarse para el amperaje y voltaje correctos Cable de energ a Bl
5. a probar el aparato Si no se requiere un cambio haga controlar el cableado del edificio para verificar conexiones y voltaje adecuados Se recomienda cambiar el reloj si aparecen las l neas rojas e Aseg rese de que los controles de la cocina se encuentren en la posici n OFF apagado antes de alejarse de la cocina
6. through the strain knockout ring away from the bracket and relief and tighten Allow enough slack twist until ring is removed to easily attach the cord terminals to the terminal block If tabs are present at the end of the winged strain relief they can be removed for better fit NOTE Do not install the power cord without a strain relief The strain relief bracket MUST be installed before reinstalling the rear range wiring cover Terminal block appearance gt fr may vary Knockout ring in bracket Strain relief Knockout ring Terminal removed Bracket Power cord D For 3 4 conduit installations only purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole Insert the conduit through the squeeze connector and tighten Allow enough slack to easily attach the wires to the terminal block NOTE Do not install the conduit without a squeeze connector The squeeze connector MUST be installed before reinstalling the rear range wiring cover Squeeze connector Terminal block Conduit Bracket PROCEED TO STEP 5 OR 6 5 3 WIRE INSTALLATION AWARNING The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block and the ground strap must connect the neutral terminal to the ground plate The power leads must be connected to the lower left and the lower right terminals of the terminal block
7. Installation Instructions Free Standing Electric Ranges Questions Call 1 800 GE CARES 1 800 432 2737 or visit www geappliances com In Canada call 1 800 561 3344 or visit www geappliances ca 2 PREPARE THE OPENING FOR INDOOR USE ONLY See illustrations for all rough in and spacing dimensions The range may be placed with 0 clearance flush at the back wall and side walls of the cabinet SINGLE OVEN DOUBLE OVEN BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT observ all governing codes and ordinances Note to Installer Be sure to leave these instructions with consumer FOR YOUR SAFETY AWARNING All ranges can tip BURNS or other SERIOUS INJURIES can result INSTALL and CHECK the ANTI TIP bracket following the instructions supplied with the bracket If you did not receive an anti tip bracket with your purchase Note to consumer Keep these instructions for future reference Skill level Installation of this appliance requires a qualified installer or electrician Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under warranty A WARNING Before beginning the installation switch power off at service panel and lock the service disconnecting means to prevent power from Anti Tip Bracket being switched
8. S ENTRE LA ESTUFA LAS PAREDES Y SOBRE LA PARTE SUPERIOR DE LA ESTUFA A Verifique que el revestimiento de las paredes el mostrador el piso y los gabinetes ubicados alrededor de la cocina puedan soportar el calor hasta 200 F generado por la cocina Deje un espacio de 30 como minimo entre las unidades de superficie y la parte inferior de gabinetes de madera o de metal sin protecci n o deje un m nimo de 24 cuando la parte inferior del gabinete de 30 t 15 Min madera o metal se encuentre protegida por cart n aislante de un grosor no menor a 1 4 y con retardo de llama cubierto con una placa de metal no menor a MSG N 28 acero inoxidable de un grosor de 015 aluminio de 024 o cobre de 020 Este aparato ha sido aprobado para un espacio de 0 respecto de superficies adyacentes sobre la estufa Sin embargo se recomienda un espacio m nimo de 6 respecto de superficies menores a 15 sobre la estufa y gabinete adyacente para reducir la exposici n al vapor salpicaduras de grasa y calor Para reducir el riesgo de quemaduras o incendios cuando se incline sobre los elementos de superficie Calientes debe evitarse la instalaci n de espacios de almacenamiento en gabinetes sobre la estufa Si debe contarse con espacio para almacenamiento en gabinetes sobre la estufa puede reducirse el riesgo instalando una campana de cocina que sobresalga por lo menos
9. c digos locales proh ben la conexi n a tierra a trav s de un conductor De aasi h Bloque terminal neutral consulte la secci n sobre conexiones en circuito derivado de cuatro conductores la apariencia puede cambiar de tensi n con alas stas pueden quitarse para un ajuste mejor Consulte a las empresas de servicio p blico sobre los c digos el ctricos que se aplican en su rea No realizar el cableado de su horno de acuerdo con los c digos vigentes puede provocar una situaci n peligrosa Si no existen c digos locales su cocina debe contar con cables y fusibles que cumplan con los requisitos del C digo El ctrico Nacional ANSI NFPA No 70 ltima edici n Este electrodom stico debe recibir el voltaje y frecuencia adecuados y debe conectarse a un circuito derivado individual con adecuada conexi n a tierra de 40 amperios m nimo protegido por un interruptor de circuitos o fusible con retraso Utilice s lo un cable para cocinas de 3 o 4 conductores aprobado por UL Estos cables pueden contar con terminales de anillo en alambre y un dispositivo de alivio de tensi n Se requiere un cable para cocinas clasificado para 40 amperios con rango de voltios m nimo de 125 250 No se recomienda un cable de 50 amperios pero si se utiliza debe se alizarse para usarse con aberturas de conexi n de un di metro nominal de 1 3 8 Debe tenerse cuidado al centrar el cable y el alivio de tensi n dentro del orificio de expu
10. cord A WARNING To prevent fire or shock do not use an extension cord with this appliance A WARNING To prevent shock remove house fuse or open circuit breaker before beginning installation We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician After installation have the electrician show you how to disconnect power from the range You must use a single phase 120 208 VAC or 120 240 VAC 60 hertz electrical system If you connect to aluminum wiring properly installed connectors approved for use with aluminum wiring must be used Effective January 1 1996 the National Electrical Code requires that new construction not existing utilize a 4 conductor connection to an electric range When installing an electric range in new construction mobile home recreational vehicle or an area where local codes prohibit grounding through the neutral conductor refer to the section on four conductor branch circuit connections Check with your local utilities for electrical codes which apply in your area Failure to wire your oven according to governing codes could result in a hazardous condition If there are no local codes your oven must be wired and fused to meet the National Electrical Code NFPA No 70 latest edition available from the National Fire Protection Association This appliance must be supplied with the proper voltage and frequency and connected to an individual properly gro
11. e la cocina Bloque gt terminal Puntas de los cables Tornillo de conexi n a tierra REEMPLACE LA TAPA DE LOS CABLES Reemplace la tapa de los cables de la cocina deslizando el lado izquierdo bajo las leng etas de retenci n y reemplazando los cinco tornillos quitados anteriormente Verifique que los cables no hayan sufrido pellizcos entre la tapa y la parte trasera de la cocina CAVIDAD NICA CAVIDAD DOBLE Parte trasera de la cocina Parte trasera de la cocina j a e lo 5 tornillos para quitar la Tornillo para tapa del quitar la cable tapa del bloque terminal Leng etas de retenci n A fin de reducir el riesgo de inclinar la cocina sta deber AADVE RTENCIA estar asegurada con un soporte anti volcaduras Lea las instrucciones de instalaci n que se enviaron con el soporte para obtener un detalle completo antes de comenzar la instalaci n A fin de controlar que el soporte est instalado y adosado u otras LESIONES GRAVES correctamente retire el caj n de almacenaje o la parte INSTALE y CONTROLE el soporte inferior delantera y observe debajo de la cocina que la ANTI VOLCADURAS siguiendo las pata niveladora est adosada al soporte En modelos que instrucciones suministradas con el ho poseen un caj n de almacenaje o parte inferior soporte delantera incline con cuidado la coci
12. f the terminal block The grounding lead must be connected to the frame of the range with the ground plate and the green ground screw FOR POWER CORD INSTALLATION A Remove the 3 lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut and discard the ground strap DO NOT DISCARD ANY SCREWS B Insert the one ground screw into the power cord ground wire terminal ring through the ground plate and into the frame of the range C Insert the 3 terminal screws removed earlier through each power cord terminal ring and into the lower terminals of the terminal block Be certain that the center wire white neutral is connected to the center lower position of the terminal block Tighten screws securely into the terminal block FOR CONDUIT INSTALLATION A Loosen the 3 lower terminal screws on the terminal block Remove the ground screw and ground plate and retain them Cut and discard the ground strap DO NOT DISCARD ANY SCREWS Strip wire to exposed tip about 5 8 long B Insert the ground bare wire tip between the range frame and the ground plate removed earlier and secure it in place with the ground screw removed earlier Insert the bare wire white neutral tip through the bottom center of the terminal block opening Insert the two side bare wire tips into the lower left and the lower right terminal block openings C Tighten the screws until the wire is firmly secured 35 to 50 inch lbs
13. g countertop flooring and cabinets around the range can withstand the heat up to 200 F generated by the range B Allow 30 minimum clearance between surface units and bottom of unprotected wood or metal cabinet or allow a 24 minimum when bottom of wood or metal cabinet is protected by no less than 1 4 thick flame retardant millboard covered with not less than No 28 MSG sheet metal 015 015 thick stainless steel 024 aluminum or 020 copper This appliance has been approved for 0 spacing to adjacent surfaces above the cooktop However a 6 minimum spacing to surfaces less than 15 above the cooktop and adjacent cabinet is recommended to reduce exposure to steam grease splatter and heat To reduce the risk of burns or fire when reaching over hot surface elements cabinet storage space above the cooktop should be avoided If cabinet storage space is to be provided above the cooktop the risk can be reduced by installing a range hood that projects at least 5 beyond the front of the cabinets Cabinets installed above the cooktop must be no deeper than 13 3 ELECTRICAL REQUIREMENTS A WARNING This appliance must be properly grounded A WARNING ali new constructions mobile homes recreational vehicles and installations where local codes do not allow grounding through neutral require a 4 conductor UL listed range
14. ibir uno sin costo En Canad lame al 1 800 561 3344 Para recibir instrucciones de instalaci n del soporte visite GEAppliances com En Canad GEAppliances ca HERRAMIENTAS NECESARIAS Perforadora con Tijeras para broca de 1 8 hojalata Gafas de Cinta m trica seguridad Alicates Llave ajustable Llave de tuercas Nivel de 1 4 MATERIALES QUE PUEDE NECESITAR Aprobados por UL de 40 AMP Cable de 4 alambres de 4 de largo O Cable de 3 alam bres de 4 de largo Conector de presi n S lo para instala ciones con conductos portacables 1 QUITE LOS MATERIALES DE ENV O no quitar los materiales de empaque puede provocar da os al electrodom stico Quite todas las partes de empaque del horno bandejas elementos calentadores y caj n Tambi n quite la pel cula protectora y las etiquetas de la puerta exterior estufa y panel de control En los modelos con cajones 451 2 de horneado o calentadores el tomacorriente no debe hallarse en esta rea es 17 rea aceptable para tomacorriente Oriente el tomacorriente para que la longitud sea paralela al piso Los modelos de marca GE cuentan con paneles de control de un ancho de 30 7 8 NOTA Utilice un cable de energ a de 4 para evitar una l interferencia con el caj n de almacenamiento Los cables de energ a de 41 a 6 de largo pueden tener que cubrirse para poder cerrar el caj n correctamente DIMENSIONES M NIMA
15. l for proper replacement e Check to make sure that the rear leveling leg is fully inserted into the Anti Tip bracket and that the bracket is securely installed OPERATION CHECKLIST e Turn on one of the surface units to observe that the element glows within 60 seconds Turn the unit off when glow is detected If the glow is not detected within the time limit recheck the range wiring connections If change is required retest again If no change is required have building wiring checked for proper connections and voltage e Check that the Clock on models so equipped display is energized If a series of horizontal red lines appear in the display disconnect power immediately Recheck the range wiring connections If change is made to connections retest again If no change is required have building wiring checked for proper connections and voltage It is recommended that the clock be changed if the red lines appear e Be sure all range controls are in the OFF position before leaving the range Instrucciones de instalaci n Cocinas el ctricas independientes Pregu ntas Llamada 1 800 GE CARES 1 800 432 2737 o visita www geappliances com En Canad llame 1 800 561 3344 o visita www geappliances ca 2 C MO PREPARAR LA ABERTURA PARA USO EN EL INTERIOR SOLAMENTE Ver ilustraciones con todas las dimensiones de empotrado y de espacio La cocina puede ubicarse con un espacio de 0 alineado sobre la pared trasera y las paredes latera
16. les del gabinete HORNO SIMPLE HORNO DOBLE Nota al consumidor Conserve estas instrucciones para referencia futura Nivel de destreza La instalaci n de este aparato debe efectuarla un instalador o s IM PORTANTE Guarde estas electricista calificado maes para el uso de inspectores El instalador tiene la responsabilidad de efectuar una instalaci n adecuada IMPORTANTE e Siga todos los La garant a no cubre las fallas del producto c digos y ordenanzas vigentes debido a una instalaci n incorrecta Nota al instalador Aseg rese de dejar estas instrucciones con el consumidor ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento PARA SU SEGURIDAD AADVERTENCIA Todas las cocinas pueden volcarse e Pueden provocarse QUEMADURAS u otras LESIONES GRAVES INSTALE y CONTROLE el soporte A ADVERTENCIA Antes de comenzar la instalaci n apague el encendido en el panel de servicio y bloquee el medio de desconexi n del servicio a fin Kit de soporte de evitar que el encendido se ANTI VOLCADURAS siguiendo las 2 t Volcaduras active de forma accidental instrucciones suministradas con el incluido Cuando el medio de soporte desconexi n del servicio no se pueda bloquear ajuste de manera segura un tem de advertencia que est bien visible tal como una etiqueta sobre el panel de servicio Si no recibi un soporte anti volcaduras con su compra llame al 1 800 626 8774 para rec
17. lsi n para evitar que el borde da e el cable La placa de clasificaci n se encuentra ubicada sobre el caj n de almacenamiento en el marco del horno o en el lado del marco del caj n HORNO SIMPLE HORNO DOBLE Placa de JS Placa de clasificaci n clasificaci n NOTA No instale el cable de energ a sin un alivio de tensi n El soporte del alivio de tensi n DEBE instalarse antes de Anillo de p volver a colocar la tapa del cableado expulsi n trasero de la cocina en el soporte Alivio de tensi n 1 Anillo de E ig expulsi n VA Aj ja terminal quitado D S lo para instalaciones con conducto portacables de 3 4 adquiera un conector de presi n que se ajuste al di metro de su conducto e inst lelo en el orificio Introduzca el conducto a trav s del conector de presi n y ajuste Deje un largo suficiente para poder pegar los cables al bloque terminal NOTA No instale el conducto sin un conector de presi n El conector de presi n DEBE instalarse antes de volver a colocar la tapa del cableado trasero de la cocina Cable de gt gt Soporte energ a Conector de presi n Bloque terminal Siga con el paso 506 5 INSTALACI N DE TRES 3 ALAMBRES AADVERTENCIA El cable neutral o a tierra del cable de energ a debe estar conectado a la terminal neutral ubicada en el centro del bloque terminal y la cinta de conexi n a tierra debe conectar la terminal neutral a la placa de conexi n a tierra
18. na hacia adelante El soporte deber a detener la cocina dentro de las cuatro pulgadas De no ser as el soporte deber ser instalado nuevamente Si la cocina es expulsada de la pared por alguna raz n siempre repita este procedimiento a fin de verificar que est asegurado de forma correcta con un soporte anti volcaduras Nunca elimine completamente las patas niveladoras ya que de ser as la cocina no estar adecuadamente asegurada por el dispositivo anti volcaduras e Todas las cocinas pueden volcarse e Pueden provocarse QUEMADURAS 9 NIVELE LA COCINA A ADVERTENCIA nunca quite las patas de nivelaci n por completo ya que la cocina no quedar bien sujeta al dispositivo anti volcaduras MODELOS CON CAJONES DE ALMACENAMIENTO O PANELES DE PROTECCI N Enchufe la unidad y desl cela en su lugar Tire del caj n hacia fuera hasta que pare Levante el frente del caj n hasta que las trabas superen las gu as Retire el caj n Instale los estantes del horno en el horno y coloque la cocina en la ubicaci n donde se va a instalar Controle la nivelaci n colocando un nivel de burbuja de aire sobre uno de los estantes del horno Haga dos lecturas con el nivel ubicado en diagonal primero en una direcci n y luego en la otra Las patas de nivelaci n frontales pueden ajustarse desde la parte inferior y las patas traseras pueden ajustarse desde la parte superior o inferior Utilice una llave ajustable para ajustar las patas nivelado
19. nstrucciones no existentes utilicen una conexi n de cuatro conductores a una cocina el ctrica Cuando instale una cocina el ctrica en una nueva construcci n una casa rodante un veh culo 4 INSTALACI N DE CABLE DE ENERG A Y DE PASACABLES A Quite la tapa del cable en la parte trasera de la cocina quitando tornillos mediante una llave de tuercas de LES No elimine esos tornillos ORNO SIMPL HORNO DOBLE Parte trasera de la cocina pe J a e Parte trasera de la cocina lo 5 tornillos para Leng etas quitar la de 4 A mE tapa del l Tornillo para retenci n ie quitar la tapa del bloque terminal Tapa gde los cablgs Tapa del bloque terminal Para cable de energ a y pasacables de 1 solamente Quite el anillo de expulsi n 1 3 8 ubicado en el soporte directamente debajo del bloque terminal Para quitar el anillo utilice un par de alicates para doblar el anillo de expulsi n lejos del soporte y gire hasta remover el anillo S lo para instalaciones de cable de energ a ver el paso siguiente si utiliza un conducto portacables instale el alivio de tensi n en el orificio Introduzca el cable de energ a a trav s del alivio de tensi n y ajuste Deje un largo suficiente para poder conectar las terminales de cable al bloque terminal Si hay leng etas al final del alivio recreativo o un rea donde los
20. on accidentally Kit Included When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel call 1 800 626 8774 to receive one at no cost In Canada call 1 800 561 3344 For installation instructions of the bracket visit www geappliances com In Canada www geappliances ca MATERIALS YOU MAY NEED Squeeze Connector For Conduit Installations Only UL Listed 40 AMP 4 Wire Cord 4 long OR 3 Wire Cord 4 long TOOLS YOU WILL NEED Drill with 1 8 Bit Tin Snips Safety Glasses Tape Measure Adjustable Wrench Pliers Level 1 4 Nut Driver 1 REMOVE PACKAGING MATERIALS Failure to remove packaging materials could result in damage to the appliance Remove all packing parts from oven racks heating elements and drawer Also remove protective film and labels on the outer door cooktop and control panel On models with baking 21 or warming drawers 2 electrical outlet must not be in this area Ne 47 Acceptable electrical outlet area Orient electrical receptacle so the length is parallel to floor GE branded models have control panels 30 7 wide NOTE Use a 4 power cord to prevent interference with the storage drawer Power cords 4 to 6 long may have to be dressed to allow for proper drawer closing MINIMUM DIMENSIONS BETWEEN COOKTOP WALLS AND ABOVE THE COOKTOP A Make sure the wall coverin
21. oque terminal la apariencia dh Bloque puede cambiar 5 terminal Conducto portacables Terminal neutral Cinta de conexi n a tierra Placa de conexi n a tierra Conducto portacables Cable de energ a SIGA CON EL PASO 7 08 08 JR 6 INSTALACI N DE 4 ALAMBRES A ADVERTENCIA El cable neutral del circuito de suministro debe estar conectado a la terminal neutral ubicada en el centro inferior del bloque terminal Los cables de energ a deben estar conectados a las terminales inferior izquierda e inferior derecha del bloque terminal El cuarto cable a tierra debe estar conectado al marco de la cocina con la placa de conexi n a tierra y el tornillo a tierra PARA INSTALACI N DE CABLE DE ENERG A A Quite los 3 tornillos inferiores del bloque terminal Quite el tornillo a tierra y la placa de conexi n a tierra y cons rvelos Corte y descarte la cinta de conexi n a tierra NO ELIMINE NINGUN TORNILLO B Introduzca el tornillo de conexi n a tierra dentro del anillo terminal de conexi n a tierra del cable de energ a a trav s de la placa de conexi n a tierra y dentro del marco de la cocina C Introduzca los 3 tornillos de terminal quitados antes a trav s de cada anillo de terminal de cable de energ a y dentro de las terminales inferiores del bloque terminal Aseg rese de que el alambre central blanco neutral se encuentre conectado a la posici n central inferior del bloque terminal Ajuste bien los tornillos al blo
22. que terminal PARA INSTALACI N DE CONDUCTO PORTACABLES A Afloje los tres tornillos inferiores del bloque terminal Quite el tornillo a tierra y la placa de conexi n a tierra y cons rvelos Corte y descarte la cinta de conexi n a tierra NO ELIMINE NINGUN TORNILLO B Introduzca la punta pelada del cable a tierra entre el marco de la cocina y la placa de conexi n a tierra quitada antes y aseg rela en su lugar con el tornillo de conexi n a tierra quitado antes Introduzca la punta pelada del cable blanco neutral a trav s del centro inferior de la abertura del bloque terminal Introduzca las dos puntas de cable pelado dentro de las aberturas de bloque terminal izquierda inferior y derecha inferior C Ajuste los tomillos hasta que el cable quede bien firme 35 a 50 pulg lbs No ajuste los tornillos de m s NOTA CABLEADO DE ALUMINIO Puede utilizarse cable de construcci n de aluminio pero debe clasificarse para el amperaje y voltaje correctos para poder realizar la conexi n Antes Cable de energ a Despu s Cable de energ a y conducto portacables Cinta de Terminal conexi n a tierra Bloque AE neutral f terminal 2 iw ks Bloque pl el 2 of UY Placa de terminal p S ome conexi n a tierra z z conexi n a tierra de la cocina Cinta de Tornillo de A conexi n Terminal conexi n a tierra Reutral atiera des GROUND Despu s Conducto portacables Placa de conexi n a tierra conexi n a tierra d
23. ras hasta que la cocina quede nivelada Nivel de burbuja de aire Alle 9 e e gt gt 9 NIVELE LA COCINA CONT G Coloque el cable de modo que no interfiera con el caj n Coloque el riel del caj n en las gu as Empuje el caj n Nivelador hacia adentro hasta que pare de JP oN Levante el frente del caj n y empuje hasta que las trabas superen Levante la S2 las guias cocina 1 Baje el frente del caj n y empuje hacia adentro hasta que cierre MODELOS CON CAJONES DE HORNEADO O CALENTADORES U HORNO DOBLE Enchufe la unidad Mida la altura de su mostrador de encimera en la parte trasera de la aber tura X Ajuste las dos patas de nivelaci n traseras para que la parte trasera de la estufa se encuentre a la misma altura del mostrador Y Deslice la unidad en su lugar Instale los estantes del horno en la unidad y coloque la cocina donde se instalar Controle la nivelaci n colocando un nivel de burbuja de aire sobre uno de los estantes del horno Haga dos lecturas con el nivel ubicado en diagonal primero en una direcci n y luego en la otra k m e o e gt a Ajuste las patas de nivelaci n frontales hasta que la cocina quede nivelada LISTA DE CONTROL FINAL DE LA INSTALACI N e Verifique que el interruptor de circuitos se encuentre cerrado RESET o que los fusibles del circuito se hayan reemplazado e Aseg rese de que se cuente con suministro el ctrico en el edificio e Controle que se ha
24. terfere with drawer Place drawer rail on guides Push the drawer in until it stops Lift front of drawer and push in until the stops clear Leg the guides leveler H El le Lower the front of the drawer and push in until it closes ODELS WITH BAKING WARMING DRAWERS OR DOUBLE OVEN Plug in the unit Measure the height of your countertop at the rear of the opening X Adjust two rear leveling legs so that the rear of cooktop is at the same height as the counter Y Slide unit into place Install oven shelves in the oven and position the range where it will be installed Check for levelness by placing a spirit level on one of the oven shelves Take two readings with the level placed diagonally first in one direction and then the other a Fee eee Adjust front leveling legs until the range is level FINAL INSTALLATION CHECKLIST e Check to make sure the circuit breaker is closed RESET or the circuit fuses are replaced e Be sure power is in service to the building e Check that all packing materials and tape have been removed This will include tape on metal panel under control knobs if applicable adhesive tape wire ties cardboard and protective plastic Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated e Check that the door and drawer are parallel to each other and that both operate smoothly If they do not see the Owner s Manua
25. unded 40 amp minimum branch circuit protected by a circuit breaker or time delay fuse Use only a 3 conductor or a 4 conductor UL listed range cord These cords may be provided with ring terminals on wire and a strain relief device A range cord rated at 40 amps with 125 250 minimum volt range is required A 50 amp range cord is not recommended but if used it should be marked for use with nominal 134 diameter connection openings Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable The rating plate is located on the oven frame or on the side of the drawer frame SINGLE OVEN DOUBLE OVEN Rating plate 6 Rating plate POWER CORD AND CONDUIT INSTALLATION A Remove wire cover on the back of range by removing screws using a 1 4 nut driver Do not discard these screws SINGLE OVEN Back of range DOUBLE OVEN Back of range P 5 screws to AA remove Retaining wire cover tabs Screw to remove terminal block cover Wire cover Terminal block cover For power cord and 1 conduit only remove For power cord installations only the knockout ring 13 located on bracket see the next step if using conduit directly below the terminal block To remove assemble the strain relief in the hole the knockout use a pair of pliers to bend the Insert the power cord
26. without a storage drawer or kick panel carefully tip the range forward The bracket should stop the range within 4 inches If it does not the bracket must be reinstalled If the range is pulled from the wall for any reason always repeat this procedure to verify the range is properly secured by the anti tip bracket Never completely remove the leveling legs or the range will not be secured to the anti tip device properly All ranges can tip BURNS or other SERIOUS INJURIES can result INSTALL and CHECK the ANTI TIP bracket following the instructions supplied with the bracket 9 LEVEL THE RANGE A WARNING never completely remove the leveling leg as the range will not be secured to the anti tip device properly MODELS WITH STORAGE DRAWER OR KICK PANELS Plug in unit and slide into place Pull drawer out until it stops Lift front of drawer until the stops clear the guide Remove the drawer Install the oven shelves in the oven and position the range where it will be installed Check for levelness by placing a spirit level on one of the oven shelves Take two readings with the level placed diagonally first in one direction and then the other The front leveling legs can be adjusted from the bottom and the rear legs can be adjusted from the top or the bottom Use an adjustable wrench to adjust the leveling legs until the range is level Ale a see 9 LEVEL THE RANGE CONT Position cord so that it does not in
27. ya quitado todo el material de empaque y la cinta Esto incluye cinta sobre el panel de metal bajo las perillas de control si corresponde cinta adhesiva ataduras de alambre cart n y pl stico protector No quitar estos materiales puede provocar da os al electrodom stico una vez que el aparato se haya encendido y las superficies se hayan calentado e Controle que la puerta y el caj n se encuentren paralelos y que los dos funcionen correctamente Si no es as consulte el Manual del propietario para un reemplazo adecuado e Controle que la pata de nivelaci n trasera est bien introducida dentro del soporte anti volcaduras y que el soporte se encuentre bien instalado LISTA DE CONTROL DE FUNCIONAMIENTO e Accione una de las unidades de superficie para observar que el elemento se encienda dentro de los 60 segundos Apague la unidad cuando se detecte el encendido Si no se detecta el encendido dentro del l mite de tiempo vuelva a verificar las conexiones del cableado de la cocina Si se requiere un cambio vuelva a probar el aparato Si no se requiere un cambio haga controlar el cableado del edificio para verificar conexiones y voltaje adecuados e Controle que la pantalla del reloj en modelos que lo incluyan reciba energ a Si en la pantalla aparecen una serie de l neas rojas horizontales desconecte la energ a de inmediato Vuelva a controlar las conexiones del cableado de la cocina Si se efect a un cambio en las conexiones vuelva